Document B5gLx6v0EQEq79xZR4oawZ6Km

._ Ofl Bamera Heating System Water Heaters Air Conditioning Unit Ray Oil Burner Co. Since 1872 401-499 Bernal Avenue San Francisco 12, Cal. Distributors in All Principal Cities of the World Atlantic Seaboard Division 629 Grove Street Jersey City 2, N. J. Consult your local Telephone Directory Products: A complete line of Horizontal Rotary and Pressure Atomizing Oil Burners; Combination Oil-or-Gas Burners; Industrial Gas Burners; Oil Burning Water Heat ers ; Winter Air Conditioning Units, Commercial Ranges. Oil Burners Heating Systems Heaters 79 Air Conditioning Unit Ray Oil Burner Co. Since 1872 401-499 Bernal Avenue San Francisco 12, Cal. Atlantic Seaboard Division .629 Grove Street Jersey City 2, N. J. There is a RAY Burner for every Heating Purpose. RAY COMBINATION OIL-GAS BURNER Type ARC-131 I to 1000 Botler hp Type AG. Manual, Semi-Au tomatic. Type ARJP, Fully Au tomatic for heavy oU where gas for ignition not available. Fully A utomatic Type All-134, for No. 5 oil. Combination OH and High Pressure Gas, Type AR-HN. Quad-Naught for ft 3 oH, manual operation. Steam Turbine Drive, Type TG, all grades oil. Tested and approved for U. S. Navy Service. Two, 6 oven, fully auto matte oH Ranges. RAY HORIZONTAL ROTARY OIL BURNERS Built in fully automatic, semi-automatic and manual types; in sizes from 1 to 1000 Boiler hp; to burn all grades of fuel oil. Standard models include both direct and belt drives--the latter being recommended for use where other than SO or 60 Cycles AC, or only DC is available. Types for straight elec tric or straight gas ignition; pump or gravity feeds. Direct drive types include a steam turbine driven model. All fully automatic types for heavy oil incorporate the Ray Dual Pump and Reservoir, with the Ray VISCOSITY Valve, a patented, exclusive feature which automatically meters the correct amount of fuel at all times, regardless of changes in viscosity of the oil due to temperature variations. All larger sizes employ dual ignition, for maximum reliability. RAY PRESSURE ATOMIZING OIL BURNERS Fully automatic, for No. 3 oil or lighter. AC or DC; capaci ties to 18 gal/hr. RAY INDUSTRIAL GAS BURNERS For gas, pressures above 1 lb/sq in. may be used alone or in combination with a Ray Oil Burner. Built in eleven sizes; in capacities to 43,000,000 Btu/hr. RAY WINTER AIR CONDITIONING UNITS Built in four sizes, with input capacities of 105,000, 140,000, 230,000, 350,000, 450,000 Btu. RAY OIL WATER HEATERS Two sizes. Capacities: 45 and 75 gal. Maximum recover rates: 154 and 240 gph. RAY OIL FIRED RANGES Available in seven sizes for manual or fully automatic operation: Type BR-141, Bell Drive Automatic. Available in 9 sizesfrom | to 100 gph. Raj/ OH Furnace, Winter, Small capacity ($ to 2} Air Conditioning Unit. gph) rotary burner. 1288 Fully Automatic, Type JP, S3 or lighter oH. Burns any grade of gas or heavy fuel oil and the opera tion is fully automatic for either fuel. Prevention against ignition or flame failure one hundred per cent electronically controlled. Develops from 7 to 335 Boiler hp. Quickly inter changeable in two to three minutes. Other types with choice of direct or belt drive, also sizes rated from 120 to 1000 Boiler hp. HOURLY CAPACITY RATINGS of RAY OIL BURNERS Burner E { XP-2 0i 3l 83 A12 Oil CaDacitv U. S. Gallons tMin. . 8 Max. 3 4 s 18 0.5 2.5 0.5 2.5 2.5 25 15 8 20 33 50 67 25 100 35 150 50 210 75 320 Equivalent Boiler HP Min. 3` 3 9 25 Max. 9 12 25 56 28 28 38 7 16 13 35 17 50 27 65 35 110 40 165 50 225 85 335 120 500 165 700 250 1000 Equivalent Generated Min. Max. 110 325 110 430 325 865 865 1950 60 290 60 290 110 290 230 580 460 1250 580 1720 930 2300 1150 1400 1720 2900 3800 5800 7750 11500 4000 5800 8700 17400 24400 37000 Heat Capacity Input Thou. Btu Min. 140 140 420 1120 Max. 420 560 1120 2500 75 375 75 375 150 375 300 750 600 750 1200 1650 2250 3000 1500 1800 2250 3750 4950 7500 10000 15000 5250 7500 11250 22500 31500 48000 Equivalent Sq. Ft. Steam Radiation Min. 438 438 1310 3500 Max. 1310 1750 3500 7900 234 234 ` 469 938 1170 1170 1170 2350 1870 2350 3750 5170 7030 9380 4690 5620 7030 11700 -- -- -- 15500 23400 31400 46900 -- -- ----- =---- NOTE* These ratings are predicated upon specific conditions of draft and furnace volume. It may be per-. ` missible, under desirable conditions, to operate at higher rates, or advisable under restricted condi tions, to operate at reduced rates- ,. , . j .innnno*___ IleaLiug capacities arc based upon 150,000 Btu per gal of oil for rotary burners and 140,000 mu per gal ofoil for pressure atomizing burners and upon an overall boiler efficiency of 75 per cent. 1289