Document B5gLx6v0EQEq79xZR4oawZ6Km
._
Ofl Bamera
Heating System Water Heaters
Air Conditioning Unit
Ray Oil Burner Co.
Since 1872
401-499 Bernal Avenue San Francisco 12, Cal.
Distributors in All Principal Cities of the World
Atlantic Seaboard Division 629 Grove Street
Jersey City 2, N. J.
Consult your local Telephone Directory
Products: A complete line of Horizontal Rotary and Pressure Atomizing Oil Burners;
Combination Oil-or-Gas Burners; Industrial Gas Burners; Oil Burning Water Heat ers ; Winter Air Conditioning Units, Commercial Ranges.
Oil Burners
Heating Systems Heaters
79
Air Conditioning Unit
Ray Oil Burner Co.
Since 1872
401-499 Bernal Avenue San Francisco 12, Cal.
Atlantic Seaboard Division
.629 Grove Street Jersey City 2, N. J.
There is a RAY Burner for every Heating Purpose.
RAY COMBINATION OIL-GAS BURNER
Type ARC-131
I to 1000 Botler hp Type AG. Manual, Semi-Au tomatic.
Type ARJP, Fully Au tomatic for heavy oU where gas for ignition not available.
Fully A utomatic Type All-134, for No. 5 oil.
Combination OH and High Pressure Gas, Type AR-HN.
Quad-Naught for ft 3 oH, manual operation.
Steam Turbine Drive,
Type TG, all grades oil. Tested and approved for U. S. Navy Service.
Two, 6 oven, fully auto matte oH Ranges.
RAY HORIZONTAL ROTARY OIL BURNERS Built in fully automatic, semi-automatic and manual types; in sizes from 1 to 1000 Boiler hp; to burn all grades of fuel oil. Standard models include both direct and belt drives--the latter being recommended for use where other than SO or 60 Cycles AC, or only DC is available. Types for straight elec tric or straight gas ignition; pump or gravity feeds. Direct drive types include a steam turbine driven model. All fully automatic types for heavy oil incorporate the Ray Dual Pump and Reservoir, with the Ray VISCOSITY Valve, a patented, exclusive feature which automatically meters the correct amount of fuel at all times, regardless of changes in viscosity of the oil due to temperature variations. All larger sizes employ dual ignition, for maximum reliability.
RAY PRESSURE ATOMIZING OIL BURNERS
Fully automatic, for No. 3 oil or lighter. AC or DC; capaci ties to 18 gal/hr.
RAY INDUSTRIAL GAS BURNERS
For gas, pressures above 1 lb/sq in. may be used alone or in combination with a Ray Oil Burner. Built in eleven sizes; in capacities to 43,000,000 Btu/hr.
RAY WINTER AIR CONDITIONING UNITS
Built in four sizes, with input capacities of 105,000, 140,000, 230,000, 350,000, 450,000 Btu.
RAY OIL WATER HEATERS
Two sizes. Capacities: 45 and 75 gal. Maximum recover rates: 154 and 240 gph.
RAY OIL FIRED RANGES
Available in seven sizes for manual or fully automatic operation:
Type BR-141, Bell Drive
Automatic. Available in 9 sizesfrom | to 100 gph.
Raj/ OH Furnace, Winter, Small capacity ($ to 2} Air Conditioning Unit. gph) rotary burner.
1288
Fully Automatic, Type JP, S3 or lighter oH.
Burns any grade of gas or heavy fuel oil and the opera tion is fully automatic for either fuel. Prevention against ignition or flame failure one hundred per cent electronically controlled. Develops from 7 to 335 Boiler hp. Quickly inter changeable in two to three minutes. Other types with choice of direct or belt drive, also sizes rated from 120 to 1000 Boiler hp.
HOURLY CAPACITY RATINGS of RAY OIL BURNERS
Burner E
{
XP-2
0i 3l
83
A12
Oil CaDacitv U. S. Gallons
tMin. .
8
Max.
3 4
s
18
0.5 2.5 0.5 2.5
2.5
25
15 8 20
33 50 67 25 100
35 150 50 210 75 320
Equivalent Boiler HP
Min.
3` 3 9 25
Max.
9 12 25 56
28
28
38 7 16
13 35 17 50 27 65
35 110 40 165 50 225
85 335
120 500 165 700 250 1000
Equivalent
Generated
Min. Max.
110 325 110 430 325 865 865 1950
60 290 60 290 110 290 230 580
460 1250 580 1720 930 2300
1150 1400
1720 2900
3800 5800 7750
11500
4000
5800 8700
17400
24400 37000
Heat Capacity Input Thou. Btu
Min.
140 140 420 1120
Max.
420 560 1120 2500
75 375 75 375
150 375
300 750
600
750 1200
1650
2250 3000
1500 1800
2250 3750
4950
7500 10000 15000
5250 7500 11250
22500
31500 48000
Equivalent Sq. Ft. Steam Radiation
Min.
438 438 1310 3500
Max.
1310 1750 3500 7900
234 234 `
469 938
1170
1170 1170 2350
1870 2350
3750
5170 7030
9380
4690 5620 7030 11700
-- -- --
15500 23400 31400 46900
--
-- ----- =----
NOTE* These ratings are predicated upon specific conditions of draft and furnace volume. It may be per-. ` missible, under desirable conditions, to operate at higher rates, or advisable under restricted condi
tions, to operate at reduced rates-
,. , .
j .innnno*___
IleaLiug capacities arc based upon 150,000 Btu per gal of oil for rotary burners and 140,000 mu per
gal ofoil for pressure atomizing burners and upon an overall boiler efficiency of 75 per cent.
1289