Document B5XmdoNNXDmKKOJ26zG8LgJqk
T Environmental Analysis Laboratories
2030 Wr ght Ave^u* Ricrn-.c'd. California 94804 (4151 235 2633 CORPORATION iTWXI 910382 8132
29 December 1976
Ref: W.O. No. lSGoO-0155
03637SCS
Mr. Robert Cheney, Vice President Structural Fireproofing 90S Tclsom Street San Francisco, CA 94207
RE: Jcb Site - 1435 Market Street - San Francisco. California
Dear Mr. Cheney:
An Industrial Hygiene survey of your job site at 1435 Market Street, San Francisco, was made by LFE Environmental on December 1, 1976 to determine worker exposure to gypsum dust.
The operation involved the mixing of nionokote MK5 for application as a fire proofing material and was described as representative of the industry. The morning session consisted of collecting area and breathing zone samples of airborne dust, under existing conditions (belt driven fan at corner of work platform which was directed diagonally across platform to where the mixers were located). During the afternoon session, the above fan was relocated to a perpendicular position to both mixers about eight (8) feet away. Breathing zone samples included both open and closed face filter collection.
Air sampling results from the above samples are presented in Table 1, (enclosed,) The closed face filter collection showed a systematic -10 percent sampling bias over the open face filter collection. Morning and afternoon Jime Weighted Averages were then calculated at 49 mg/m3, 18 mg/m3, 89 mg/m3 and 35 mg/m3 for th (Ed Coston) and (Mike McKenna) mixer operators respectively. A 60 percent reduction in airborne gypsum concentrations was achieved as the result of a more effective fan placement.
If 1 can be of any additional assistance, please don't hesitate to contact me.
Sincerely yours
7
MO/llh Attachment
Maurice Oberg, D.Sc. , CIH Industrial Hygiene Services
15108650