Document B59daj3LxYXz99Lpzg30pQ5jE
[~&<^fo^AoducZ&)
INTEROFFICE MEMORANDUM To__ B. Helms_______ From cc: H. J. Smith
n,^
Data 23 November 1983
Subject Processing of Calvert City_______
Audiograms by HCI, Inc.__________
Calvert City
(Location* Organization, or Oooartmant)
Corporate Medical
(Location, Organization, or Department)
Recently I requested a computer printout from MIS listing all audiogram results of Calvert City employees presently on file. This listing has been submitted to HCI, Inc. to be entered into their Phase 4 Hearing Test Manage ment System. HCI has been testing and processing audiograms for APCI for two years. The contractor's audiogram Interpretation and reporting systems have proven useful for those managing plant hearing conservation programs. Calvert City participation in the program will require the following:
You will be contacted by HCI In the near future to arrange to have audiometric test forms sent to you. All future------jgrH oqrains should be recorded on. the MCI_fom./Audiometric data may be deleted from the APCI medical data sheet, although it may be desirable to continue to store the audiometric information along with the other medical findings in the APCI computer.
Upon completion of the testing, the HCI test form should be sent to the Virginia, Minnesota office for processing. When you receive the test form back, it should be placed In the employee's medical or personnel file.
You will receive an updated management report quarterly.
I have enclosed a copy of the instructions for using the Phase 4 Management Program. This information should serve as reference material when you begin receiving audiogram management reports. In addition you will find a copy of the Company Hearing Conservation Program Guide and sample training material. Additional brochures are available for distribution to employees. A 15minute video tape on hearing conservation entitled "Sound of Sound" is also available for your training program.
If after talking with HCI you require additional information, please feel free to contact me.
R0W:bmw Att.
1320]
AP00033251
TO: J. D. Kramer
Page -4-
SUBJECT: LABORATORY HIGHLIGHTS J JULY, 1977
18 August 1977
U-
3. All finalproduct is analyzed for VCM (ppm). The average
results are as follows:
Type
VCM, ppm
No. of Analyses
410 7121
440
6180 7121
4 01 1230P
1225 1200
9010 7123
21 1 14 8
67 6 18 17 9 48
16 18 51
126 15
10 1 12 2
4. The 0800 hour samples are analyzed for each of the three
product collectors daily. The average results are as follows:
#1 #2 #3
1200 7121
6180 1230P
410
4 01
293
17
--
--
48 ------ 29 186
--
--
3
-- -- 22
5. All PVC Plant personnel are sampled monthly using random sampling with 8-hour Sipin samples. The average results for July are shown below:
Shift
A B C D
Date
Operator Foreman Maint.
21 July 77 14 July 77 26 July 77 18 July 77
1.7 0.20 3.87
2.42
2.50 0.57 8.27 1.98
0.85
-
0.11
Laboratory
_
-
0.25 0.82
Area 5
4.58 0.63 14.05 1.29
Utilitv
0.19 1.91 0.99 0.09
6. Twenty-three lots of compound were analyzed for VCM. The average value obtained was 0.6 ppm VCM.
AP00033252