Document B57o50kZ9wbxjRXGoy3Kd0G7k

Federal Register / Vol. 51, No. 119 / Friday, June 20, 1986 / Rules and Regulations 22735 (viii) Particular products and - operations. No asbestos cement, mortar, coating, grout plaster, or similar material containing asbestos, tremolite, anthophyllite, or actinolite shall be removed from bags, cartons, or other containers in which they are shipped, without being either wetted, or enclosed, or ventilated so as to prevent effectively the release of airborne fibers of asbestos, tremolite, anthophyllite, actinolite, or a combination of these minerals so as to expose employees to levels in excess of the limit prescribed in paragraph (c) of this section. (ix) Compressed air. Compressed air shall not be used to remove asbestos, tremolite. anthophyllite, or actinolite or materials containing asbestos, tremolite, anthophyllite, or actinolite,'unless the compressed air is used in conjunction with a ventilation system designed to capture the dust cloud created by the compressed air. . (2) Compliance program, (i) Where the PEL is exceeded, the employer shall establish and Implement a written program to reduce employee exposure to or below the limit by means of engineering and work practice controls as required by paragraph (f)(1) of this section, and by the use of respiratory protection where required or permitted under this section. . (ii) Such programs shall be reviewed and updated as necessary to reflect significant changes in the status of the employer's compliance program. - (ii!) Written programs shall be submitted upon request for examination and copying to the Assistant Secretary, the Director, affected employees and designated employee representatives. (iv) The employer shall not use employee rotation as a means of compliance with the PEL. (g) Respiratoryprotection--{1) General The employer shall provide respirators, and ensure that they are used, where required by this section. Respirators shall be used in the following circumstances: .. (1) During the interval necessary to install or implement feasible engineering and work practice controls;. . (ii) In work operations, such as maintenance and repair activities, or other activities for which engineering and work practice controls are not feasible; ' (iil) In work situations where feasible engineering and work practice control^' are not yet sufficient to reduce exposure to or belc w the exposure limit; and (iv) In emergencies. . (2\Respirator selection. (i) Where. ' respirators are required.under this; ; section, the employer shall select and . provide, at no cost to the employee, the appropriate respirator as specified in Table 1. The employer shall select respirators from among those jointly approved as being acceptable for protection by the Mine Safety and Health Administration (MSHA).and by the National Institute for Occupational Safety and Health (NIOSH) under the provisions of 30 CFR Part 11. (ii) The employer shall provide a powered, air-purifying respirator in lieu of any negative pressure respirator specified in Table 1 whenever (A) An employee chooses to use this type of respirator; and (B) This respirator will provide adequate protection to the employee. Table 1Respiratory Protection for as bestos, Tremoute, Anthophyllite, and Actinolite Fibers Airborne concentration of asbestos, tremoftte, emhophylBta, acbnoihd. or a combination of Required respirator Not in excess of 2 f/ec 110 X PEL). Not in excess of 10 1/ce (SO X PEL). Not in excess of 20 l/cc (100 X PEL). Not in excess of 200 1/ cc <1000 X PEL)! Greater than 200 f/cc (> 1,000 X PEL) or unknown concentration. 1. Hatf-mask air-purtfyfng respira tor equipped wttt high-efficien cy fitters. 1. Full facepiece air-purifying res pirator aquippod with high-eKiclency fitters. 1. Any powered air-purifying respi rator equipped with hrgh-efficiency fitters. 2. Arty supptfed-air respirator op erated to continuous flow mode. 1. Foil fsceptsoe suppOed-eir res pirator operated in pressure demand mode. 1. Full facepiece suppfied air res pirator operated in pressure demand mode equipped with an BuxSiaiy positive pressure . aetl-contained breathing appa ratus. NOTE; a. Respirators assigned Cor higher towironmontal concentrations may be used at tower concentrations.. b. A high-efficiency filter means a filter that is at least 99.97 percent efficient against mono-dispersed partictoe of 0.3 micrometers or larger. (3) Respiratorprogram, (i) Where respiratory protection is required, the employer shall institute a respirator program in accordance with 29 CFR 1910.134(b). (d), (e). and (f). (ii) The'employer shall permit each employee who uses a filter respirator to change the filter elements whenever an increase in breathing resistanceis detected and shall maintain an adequate -supply of filter elements for this' purpose. (iii) Employees who wear respirators shall, be permitted to'leave the regulated area to wash their faces.and. . respirator facepieces whenever necessary to prevent skin irritation associated with respirator use. (iv) No employee shall be assigned to tasks requiring the u9e of respirators if, based upon his or her most recent examination,' an examining physician determines that the employee will be unable to function normally wearing a respirator, or that the safety or health of the employee or other employees will be impaired by the use of a respirator. Such employee shall be assigned to another job or given the opportunity to transfer to a different position whose duties he or she Is able to perform with the same employer, in the same geographical area and with the same seniority, status, and rale of pay the employee had just prior to such transfer, if such a different position is available. (4) Respirator fit testing.-(i) The ; . employer shall ensure that the respirator issued to the employee exhibits the least possible facepiece leakage and that the respirator is fitted properly. (ii) For each employee wearing negative pressure respirators, employers shall perform either quantitative or . qualitative face fit tests at the time of initial fitting and at least every six months thereafter. The qualitative fit tests may be used only for testing the fit of half-mask respirators where they are permitted to be worn, and shall be conducted in accordance with Appendix C. The tests shall be used to select facepieces that provide the required protection as prescribed in Table 1. (h) Protective work clothing and equipment--(1) Provision and iise. If an employee is exposed to asbestos, tremolite, anthophyllite. actinolite. or a combination of these minerals above the PEL, or where the possibility of eye irritation exists, the employer shall provide at no cost to the employee and ensure that the employee uses .appropriate protective work clothing . and equipment such as. but not limited to: (i) Coveralls or similar full-body work clothing; (ii) Cloves, head coverings, and foot coverings; and (iii) Face shields, vented goggles, or other appropriate protective equipment which complies with $ 1910.133 of this Part. (2) Removal and storage, (i) The employer shall ensure that employees remove work clothing contaminated with asbestos, tremolite, anthophyllite, or actinolite only in change rooms provided in accordance with paragraph . (i)(T) of this section. (ii) The ernployer shall ensure, that no employee takes contaminated work clothing out of the.change room, except those employees authorized to do so for the purpose of laundering, maintenance, or disposal. (iii) Contaminated work clothing shall be placed and stored in closed containers which prevent dispersion of the asbestos, tremolite, anthophyllite, and actinolite outside the container. GLEASON-000983