B WIRE CONNECTOR
OUTSIDE PLANT PRODUCTS MANUAL SPLICING MATERIALS 9/78
DESCRIPTION
JOINING CONDUCTORS OF CABLE OR SERVICE WIRE
The B wire connector is designed to be used on aluminum, copper, and copper-steel conductors with pulp insulation. It gives a reliable, but not waterproof, joint. It is not recommended for splicing any PIC cables.
The B wire connector is available loose or on taped rolls. In addition, the connector can be obtained lined or unlined. The lined connector has a plastie lining which is placed into the connector to prevent hang-up of wire ends which results in incomplete insertion.
A joint is made by fully inserting the ends of conductors into the E wire connector and pressing with an approved presser tool.
All B wire connector joints containing aluminum conductors, and all other joints that will be placed below ground, must be encapsulated as described in BSP 632-410-203.
Plastic Lined B Wire Connector
Where high splicing productivity is possible, taped, plastic-lined B wire connectors can be used.
The B, C, and D connector pressers are the approved presser tools for B wire connectors.
Lined, Toped B Wire Connectors
RULES FOR B WIRE CONNECTOR USAGE
Approved wire combinations are listed in BSP 632-205-201. Generally, the following rules must be observed:
(1) 26- and 24-gauge copper PIC conductors do not require insulation removal.
(2) 22-gauge and larger copper PIC conductors must be stripped back 3/4 inch.
(3) 26- through 22-gauge copper conductors insulated with pulp or paper do not require
insulation removal.
(4) 17- and 20-gauge aluminum conductors with insulation removed may be joined but
encapsulation of the joints is required.
(5) 20-gauge copper-steel conductors may be joined with the insulation removed.
(6) Remove insulation from all gauges of polypropylene-insulated conductors in filled
cable before being joined.
(7) Some combinations of the above conductors are not permitted because of large
differences in size. See BSP 632-205-201 for these combinations.
KEEP INSULATION OF SKIVVE.D CONDUCTOR WITHIN PLASTIC JACKET OF THF BWIRE CONNECTOH
I*--** -*l
Conductors Installed in B Wire Connectors
ORDERING INFORMATION
Loose: Taped:
(qty) pk, Connector, Wire, B, AT-7759, A155472 (25 pieces/pk) (qty) pk, Connector, Wire, B, AT-7759, A156471 (1000 pieces/pk) (qty) pk. Connector, Wire, B, AT-7759, A158255 (25 pieces/pk) Lined (qty) pk. Connector, Wire, B, AT-7759, A158245 (1000 pieces/pk) Lined (qty) rl, Connector, Wire, B, AT-7759, A155478, Taped (250 pieces/rl) (qty) rl, Connector, Wire, B, AT-7759, A158047, Taped-Lined (250 pieces/rl)
REFERENCES
AT-7759--Connector, Wire, B BSP 632-205-201--B Connector--Description and
Approved Conductor Combinations BSP 632-410-203--Splicing PIC Cable--Encapsulation
of Joints
Western Electric
Page 9.03
TAY0000427