when CV- n r* 1;! V uJ u'v:- i [i U GJL1 Ll.^Du J y u rJ K^J here's how to ^=y get more performance and save money TOWOLDMON0026471 WATER_PCB-00010940 the fire-resistant dielectric h7 ^ preferred by specifiers Lj ^ uj' u,i.;,3 who want to save money now and for years to come askarel fire-resistant transformers offer Lower Operating Costs due to lower power losses High Impulse Strength giving a margin of safety against transformer failure Low Maintenance Costs install them and leave 'em alone Low Installation Costs place them where YOU want them placed Fire Resistance askarel provides safety from fire Quietness naturally designed to be quieter than open dry types Reliability more than 30 years of trouble-free operation 02218*8 | TOWOLDMON0026472 WATER_PCB-00010941 additional information! Fill out the business reply in the back ol this brochure and drop it in the mail . . no postage required. why askarel... For almost 40 years askarel transformers have served the commercial, industrial and utility fields faithfully with safety, economy and reliability. They are built to exact specifications by all major electrical equipment manufacturers.. Mineral oil transformers can catch fire. When used in confined or populated areas, they require fire walls, vaults, and sprinkling systems; or they must be lo cated at a more remote point requiring long expensive low-voltage lines. Open dry type transformers are limited in flexibility of location. Supplemental installation costs usually run much higher than with askarel units, especially if sound-deadening or enclosing from atmospheric con tamination and moisture is required. They are less de pendable than askarel units because they are affected by corrosive atmospheric conditions. Due to the na ture of open dry type units, they can require a great deal of maintenance; have a high noise level, and are expensive to operate because of higher load losses and frequent maintenance requirements. Askarel units deliver a steady power flow year after year, offering lower operating and maintenance costs, quietness and dependability. They are fire-resistant and allow you to place them where YOU want them placed, right at the point of use if you choose. Think of the savings in installation alone! Askarel will not oxidize or sludge; remains chemically stable when subjected to elevated temperatures and will not corrode metals. r ' r> c: - > Monsanto has manufactured and supplied askarel fluids since the askarel type trans former was first introduced. The askarel fluid insulation is supplied under various trademarks such as "PYRANOL" (General Electric); "INERTEEN" (Westinghouse); `CHLOREXTOL" (AHis-Chalmers); "NOFLAMOL" (Wagner Eleclnc). Many other manufacturers such as l-T-E use the gen eric name, askarel. In all cases, Monsanto makes the askarel fluid lor these trans formers. o*^8,,q | TOWOLDMON0026473 WATER_PCB-00010942 askarel fire-resistant transformers operate less expensively than other types due to lower core and coil losses its just like getting ' A FREE TRANSFORMER IN ABOUT 10 YEARS! TYPICAL EXAMPLE 1,000 KVA, 3 phase, 60 cycle, 13,800 to 480 Y volts. Transformer first cost assumed about $8,500. UNIT COIL LOSS CORE LOSS (at 100% Load) (Watts) (Watts) Incorporate your own figures in the fol lowing example and prove this point to yourself. The figures shown assume the same first cost of an askarel transform er and an open dry type unit. (Askarel transformers are now quoted at the same price as 150C. open dry types.) Open Dry Type Askarel Unit 4,200 2,900 18,500 12,500 (A) Based on a 75% load factor, coil losses are ap proximately as follows: Open Dry Type.. 18,500 x (.75)2 = 10,400 watts Askarel Type .. .I2.500x (.75)2 -- 7,000watts Coil Loss Difference.. .3,400 watts Total Core and Coil Loss Difference in lavor of Askarel.............................4,700 watts Based on an 8,700 hour year operation: 4,700 x 8,700 = 41,000 KWHR (Approx.) Assuming power cost is $0,015 per KWHR: the savings each year is $615.00 ... or the Askarel Transformer first cost is paid for in about 10 years.* 'This annual savings compounded at 6% per year. L 0221850 TOWOLDMON0026474 WATER_PCB-00010943 askarel fire-resistant transformers offer easy maintenance ' LOW MAINTENANCE MEANS GREATER SAVINGS IN TIME AND MONEY! Askarel transformers are easiest to maintain. Proper sealing of modern as karel transformers has banished the 0221B51 | TOWOLDMON0026475 WATER_PCB-00010944 askarel fire-resistant transformers can give you lower installation costs place the askarel TRANSFORMER WHERE AND ' WHEN YOU WANT IT PLACED! Because of the unique features of aska rel transformers, you can place them where and when YOU want them placed . . . right at the point of power usage if you desire. You do not have to wait un til other phases of construction are com pleted. No added expenses are neces sary to protect it from contamination, subdue the sound level or run expensive lines from distant locations. You place it where your system dictates, not where the transformer dictates. The start-up costs for askarel transform ers are almost nil. Because they are sealed, there is no expensive clean-up and drying out required prior to starting. Just bring it in, hook it up and start op erating. This alone offers a big savings. askarel transformers offer fire safety ASKAREL FLUIDS ARE FIRE-RESISTANT! The fluid is fire-resistant and does not support combustion. Just as important, Ihe fluid will not carry or add burning oil hazards to fires which may start from other causes. The liquid does not de teriorate when exposed to heat or hot metal; it does not decompose over long periods of time. Municipal codes also tend to favor askarel transformer instal lations over other types. 02Z1B^ J TOWOLDMON0026476 WATER_PCB-00010945 r askarel fire-resistant transformers are quieter - ' CHECK THE STANDARDS! Open dry types produce a higher noise level, requiring expensive sound-sup pressing additions or location far from the point of power usage. Wherever the sound level is a factor, askarel trans formers rate quieter than comparable open dry type units ... 3 to 6 decibels is a major reduction in discernable sound level. askarel fire-resistant transformers are reliable THERE ARE MANY EXAMPLES OF OVER 30 YEARS OF TROUBLE-FREE OPERATION! A properly designed and installed aska rel transformer will give long years of trouble-free service . . . many in opera tion for over 30 years. This fact has been proven in installations throughout the world. Even longer life can now be ex pected due to more modern design practices in sealing out moisture and eliminating leaks. 0221853 | TOWOLDMON0026477 WATER_PCB-00010946 askarel fluids maintain high dielectric strengths The most significant and reliable meas urement of transformer askarel electrical performance is its dielectric strength. Askarel will maintain its high dielectric strength unless ihere is a significant amount of moisture contamination or breakdown of the fluid from an unusually severe electrical discharge. Askarel fluids are manufactured by Mon santo and shipped to transformer mak ers all over the world. They are manu factured and quality checked for con sistency and properly packaged for ship-q ment. 'J Transformer makers, utilities, and specitiers, in turn, handle askarel fluids under standard normal good housekeeping 1 and personal precautions used with .... other industrial products. '7 02218**, | TOWOLDMON0026478 WATER_PCB-00010947 before you specify... consider askarel transformers Operating with askarel fire-resistant transformers is the safest, easiest and often the least expensive way to distribute elecirical power. Your transformer supplier can give you the com plete story on his askarel transformers. Be sure to check with him soon . . . specifying askarel transformers is your best bet when your plans call for transformer equipment in . . . Industrial Unit Substations, Load Centers, Power Centers ... in factory areas where maximum safety from fire is re quired and where atmospheric contamination may exist. Utility Networks . . . where safety and space is a consider ation. Institutions and Office Buildings . . . schools, hospitals, ho tels, shopping centers, apartments, etc. where maximum safe ty, low noise levels and space is a prime factor. In any electrical system . . . where you are charged with the responsibility of providing the best installation available at the lowest overall installation and operational cost. .'] r. r '"t La. I t| D T IF 0221^5 | TOWOLDMON0026479 WATER_PCB-00010948 send for detailed information... Monsanto will be happy to supply you with a copy of "The Care and Grooming of Askarel Transformer Fluid" or "Mon santo Askarel Inspection and Mainte nance Guide." Ask your supplier to get your copy for you, or simply return the attached business reply card. 22la56 TOWOLDMON0026480 WATER_PCB-00010949 specify askarel for your next job! TOWOLDMON0026481 WATER_PCB-00010950