PYDRAULMC Fire Resistant, Water-Free Hydraulic Fluid
... For Mining Equipment
*
010806"
^
Bulled Mo,
Monsanto PCB-ARCH0743676
010806^
PCB-ARCH0743677
Pydrauf MC
'
A High-Performance Hydraulic Fluid For Safer
Hydraulic Operation With Minimum Maintenance
PydraulMC fire-resistant hydraulic fluid was developed spe
cifically for use in mining equipment. It is a: phosphate-ester
based formulation containing no water. It meets the fire resis
tance requirements of the U.S. Bureau of Mines Schedule #30.
Equally important, field experience since 1972 shows that Pydraul
11 u M MC^offers the following operating advantages:
..............
* Reduced Fluid Maintenance
Unlike water-based hydraulic fluids that are oil
emulsion or glycol solutions -- Pydraul MC does
not lose water by evaporation to change composition
and viscosity.
,
* Eliminates Hazards From Spillage
Water-based fluids that evaporate off their water
component can leave behind flammable residues in
reservoirs, spill pools or crevices.
* Operates At Higher Temperatures g Pressures
Pydraul MC has excellent viscosity characteristics
and a high degree of lubricity that permits efficient
hydraulic operation at pressures up to 5,000 psi.
* Gives Equipment Protection From Corrosion
41 u I J Pydraul MC^does not create a rust-promoting environ
. ment in operating equipment. It is chemically stable
to help eliminate corrosion problems.
Rendered Trfi<lernrk ofP
Comply
010806b
PCB-ARCH0743678
Monsanto's development of fire protection for industrial hydraulic operations began with the first Pydraul fluid in 1951. Pydraul fluids have since provided industry with millions of ma chine hours of safe operation.
Pydraul MC was designed to enable ore and coal mine operators meet the current safety legislation that requires a fire-resistant fluid in unattended equipment and either a fire-resistant fluid or suitable fire suppression devices in attended equipment. The initial cost and maintenance of fire suppression devices may show that a stable fluid such as Pydraul MC would be the most economical choice in the long run.
Pydraul MC is a dependable hydraulic fluid for safer operation of above- and below ground equipment with minimized maintenance. It may be used in the hydraulic systems of the following:
Power Shovefs Draglines
Blasthole Drills
Bulldozers 5 Rippers
Tractors
Scrapers 5 Graders
Crushers
Ore Feeders
Trucks
Jumbos
Ore Drills
Mechanical Loaders Scrapers
010B067
PCB-ARCH0743679
4.
The following pages give data that illustrate the typical
properties and performance of Pydraul MC as measured by standard
test procedures used to describe hydraulic operation and fire
resistance:
-
0\00b6
PCB-ARCH0743680
Pydraui^MC ^4^ Typical Physical Properties *
Appearance Specific Gravity 25/25C.
Density at 140F. 77F.
Neutralization No. (mg KOH/g) max.
Moisture (max.) t
Viscosity
'
Centistokes @ 40F.
S 100F.
e 210F.
ssu e 40F.
6 100F.
e 210F.
Clear Green Liquid 1.098
1.075 grams/ml. .1.100 grams/ml. ' 0.30
0.15
1250 cs 69 cs
6.9 cs
5800 SSU
320 SSU
48 SSU
Pour Point Coefficient of Thermal Expansion per F. Specific Heat ETU/lb./F. S 77F. Thermal Conductivity BTU/hr,/ft./F. Solubility in Water
-10F.. 0.00034 0.39 0.0728 Negligible
*Data based upon typical quality control samples tested in laboratories. Complete sales specifications are furnished on request.
0l08b9
PCB-ARCH0743681
KIN EM ATIC VISCOSITY, CEWTISTOKES
KINEM ATIC VISCOSITY, CENTISTOKES
) )
TEMPERATURE, DEGREES FAHRENHEIT
;
J
{
0108070
PCB-ARCH0743682
V>SCOSlTY, SAYBO LT U N rvBBSAL SECOWOS
0108071
PCB-ARCH0743683
7.
Pydraul^MC
J4-
Y~
-c-C.
Typical Performance Properties
Foam Test (ASTM D892) Sequence 1, 2, 3
Rust Test ASTM D-665 (Sequence A)
Hydrolytic Stability Test (MIL-H-19457)
Oxidation and Corrosion Test (FS791-3S08) (168 hr., 250F., 5 1 air per hr.)
Metal Weight Changes, Magnesium Aluminum Cadmium Steel Copper
2 mg/cm
Acidity Increase, NN
100F. Viscosity Increase, %
Pass _ Pass
Pass
-0.01 +0.05 -0.01 +0.01 -0.02
2.58 13.1
Compatibility With Materials
Metals
Pydraul MC is compatible with all the
commonly used metals of construction.
Paints Other Fluids
Cured epoxy, phenolic, polyurethane and nylon based paints are satisfactory. INTERIOR SURFACES ARE PREFERABLY LEFT '
UNPAINTED. Pydraul MC is miscible in all proportions
with the Pydraul E and Pydraul C Series of fluids. It is essentially insoluble in water.
Packings, Seals, Hoses and Bladders
Materials compatible with Pydraul MC are necessary for dynamic or moving seals. For static seals they are preferred but not essential. .
Recommended VTton NYLON TEFLON FLUOREL'
Marginal** BUTYL^ EPR
Unsatisfactory BUNA-N NEOPRENE NATURAL RUBBER
SILICONE
-2.
------ V<_ y . r
S'j'-"yJ'... CS-,
'`Although generally classified as marginal with Pydraul fluids, butyl and EPR (ethylene propylene rubber) have proven satisfactory in equipment operating
Under certain conditions of temperature, fluid cleanliness, maintenance, etc.
For best service under general all-around operating conditions, elastomers of
Viton, Nylon, Fluorel, Teflon, and silicone are suggested.
0108072
PCB-ARCH0743684
PydrauAc FireffResistance Properties
Flash Point
Fire Point
Autogenous Ignition Temperature (ASTM D2155)
Factory Mutual High Pressure Spray Test
Cfest fluid sprayed @ 1000 psi through orifice, passing through flame of propane torch.)
Factory Mutual Hot Channel Test
CTest fluid sprayed @ 1000 psi through orifice, onto hot channel iron @ 1300F.)
U.S. Bureau of Mines Approval Schedule 30
4 750 F 525F. 800F Pass Extinguished in less than S sec. after torch removed. Pass
Yes, Number 30-6
Fire Resistance Advantages of Pydraul Pydraul fluids protect hydraulic equipment and personnel with
permanent fire protection. Pydraul fluids contain no water to evaporate and leave a flammable residue. During their many millions of machine hours of use, Pydraul fluids have been acciden tally sprayed over molten metal, through electrical arcs, into flames and sparks without disaster. They pass all of the important ignition tests for fire resistance.
"NOTE: Materials designated 'fire resistant' generally are more difficult to ignite, or once ignited, bum at a slower rate than corresponding conventional materials. This term does not mean that fire resistant materials will not bum. However, when properly used. Monsanto's fire resistant PYDRAUL1'5 HYDRAULIC FLUIDS are useful in helping customers meet their fire safety requirements."
PCB-ARCH0743685
9.
CONVERTING MINING EQUIPMENT HYDRAULIC SYSTEMS TO PYDRAUL MC
Regardless of the type of hydraulic fluid being used, con verting a system to Pydraul MC is easy. Virtually every type of equipment that uses fire-resistant hydraulic fluid has been converted to Pydraul phospha turers are experienced in be consulted.
If changing seals is necessary, equipment manufacturers can recommend which to change, and many carry a supply of compatible seals. Laboratory tests and operational experience show Viton*, Teflon*, and silicone to be the preferred elastomers.
To replace other fluids which are compatible with Pydraul and where compatible seals are already in the system, it is only necessary to add Pydraul MC as make-up fluid. It is not necessary to drain or clean. However, when converting frcm petroleum oils, non-compatible synthetic fluids, water-glycol fluids, or waterin-oil emulsions -- the following steps are recommended. These conform to USA Standard B93.5 -- 1973.
Changing from Petroleum Oil
1. Completely drain and clean the system. Small amounts
of oil will not interfere with the performance of
Pydraul, but resistance to fire is reduced by the
amount of oil left in the system.
2. Drain and blow out pipelines. Manually clean valves
and reservoirs.
010807*
*Reg-fert**ctl trademark of E.I. Du Pont de Nemours 5 Co., Inc.
PCB-ARCH0743686
3. Open or remove-and-drain all valves. Replace gaskets; packings, and seals with compatible materials. It is particularly important to change dynamic seals. Static seals do not necessarily have to be changed if they are tot leaking. Non-compatible static seals can be replaced when the component is disassembled for maintenance.
4. Remove pumps, accumulators, and cylinders, if neces sary, for draining. Replace packings, seals, gaskets, and bladders with materials compatible with Pydraul.
5. Check component functions before the system is closed and fluid is. added.
6. If the system cannot be completely drained, i/ may have to be flushed out with a small amount of Pydraul.
Changing from Water-Gfycol or Water-in-Oil Emulsion 1. Drain and clean system thoroughly. Remove all traces of water. Empty all lines and low points or dead pockets in components.
2. Clean with steam or warm water. Follow by blowing with dry air.
3. Check sealing materials, hoses, and accumulator bags. Replace if necessary with compatible materials.
4. Install a minimum system from 16 to 24 hours. During this period, in spect the reservoir. If water or other contaminants float to the top, remove by skimming.
0108075
PCB-ARCH0743687
S. Drain the flushing charge immediately after shut-down
while the fluid is warm. Drain all isolated points
or parts which do not drain back to the reservoir.
If water is apparent in fluid clinging to walls, wipe
down all accessible parts.
,
Ask the Monsanto fluids specialist for suggestions and assistance. He may be reached by phoning the nearest sales office listed on the back cover.
0vft PCB-ARCH0743688
12.
Pydraul MC % y
t.
Toxicity and Safe Handling
Animal studies indicate that Pydraul MC can be classed as practically non-toxic when considered as an industrial fluid. It is non-irritating when the skin is exposed to the fluid.
In case of skin contact wash off with soap and water as a hygenic procedure. In the case of eye contact flush with copious amounts of water.
Due to its low order of toxicity, Pydraul MC requires no special handling precautions.
ovo011
PCB-ARCH0743689
r
~\
CUSTOMER SERVICE CENTERS
AKRON, OHIO 44313
260 Springtide Drive Montrose Development Park Tel. (216) 666-4111
ATLANTA, GEORGIA 30339
320 Interstate North Parkway Suite 500 Tel. (404) 432-7111
BOSTON, MASSACHUSETTS 02149
Everett Station Tel. (617) 307-5010
CHICAGO. ILLINOIS
.
3158 Dcs Plaines Ave. Dcs Plaines. Illinois 60018 . Tel (312) 296-6688
CINCINNATI, OHIO 45236
8041 Hosbrook Road Tel (513) 984-1100
DETROIT, MICHIGAN
500 Northland Towers West Southfield, Michigan 48075 Tel. (313) 357-0910
HOUSTON, TEXAS 77027
1301 Post Oak Tower 5051 Westheimer Road Tel (713) 621-9550
LOS ANGELES, CALIFORNIA
1401 Dove Street Newport Beach. California 92660 Tel (714) 833-9150
NEW YORK, NEW YORK 10036
1114 Avenue of the Americas Tel (212) 764-5000
ST. LOUIS. MISSOURI 63166
800 N. Lindbergh Blvd.
Tel (314) 694-1000
.
SAN FRANCISCO BAY AREA
2710 Lafayette Santa Clara. California 95052 Tel (408) 243-0414
SEATTLE, WASHINGTON 98121
2112 Third Avenue
Tel (206) 622-4203
j
WILMINGTON. DELAWARE 19810
Suite 204. Bancroft Bldg. 3411 Silverside Road Tel (302) 478-4600
Monsanto Industrial Chemicals Co. A Unit of Monsanto Company 800 N. Lindbergh Blvd., St. Louis, Mo. 631 GO V.____________________________ _____________)
oioeo''8
HOTICF: '`Nothinp contained herein is to be construed as a recommendation to use any product in conflict with any patent. Tf.^-C