Document 9L9Y9JDR3nLYVNbMZdVgKGkKV
Air Conditioning
Unit Heaters and Coolers
The Unit Heater and Cooler Division
D. J. Murray Mfg. Go.
Wausau, Wisconsin
Offices in Principal Cities
MANUFACTURERS OF THE GRID UNIT
(patented)
AU-cast aluminum "fins" bonded to cast high-test iron
core.
No soldered, brazed, or expand
ed joints -- no unions--no seams --fewest connec
tions Possible.
GRID UNIT HEATER DATA
Model No.
Dimensions Inches
A B c D*
Face Area Sq Ft
Motor Hp Rpm
Vol. at Fan
Capacities 5 Lb Steam 60* Air
Btu
htnai Temp.
Approx.
Shipping Weight
Pipe Size* Supply Return
1000 16% n% 9% 16 0.84
1200 l8>/2 13% 11% 17% 1.04
515 23% 17% 11% 20
1.65
1500 23% 17% 11% 20
1.67
1520 27% 17% 11% 20
2.2
520 28% 22% 11% 21% 2.9
2000 28% 22% 11% 21% 2.9
2025 33% 22>/, 11% 21% 3.6
525 35% 271% 13 28 4.5
1/20 1/20 1/10 1/10 1/10 1/6 1/6 1/6 1/2
1700 1700 1750 1750 1750 1150 1150 1150 1150
578 711 1290 1450 1700 2500 2500 2875 4200
29,400 46,000 59,600 77,500 104,000 102,300 148,000 177,000 166,400
107 100 i%" i%" 119 120 i%" !>/." 102 160 i%" !%" 109 210 i%" i'/." 113 "~250 -- i%" i%" 97 250 2" . i%" 114 320 2" i%" 115 370 2" i'/." 94 390 2" i%"
2504 35% 271% 13 28 4.5
1/4
1150
3200 210,000
118
420
2"
!%"
i'/."2500 35% 27% 13 28
4.5
1/2
1150
4200 225,000
108
440
2"
iy."2530 37% 27% 13 28. 5.3
1/2
1150
4650 282,000
115
530
2n
i%"530 39% 32% 13 29
6.5
1/2
1150
5300 260,500
105
600
PA"
3000 39% 32% 13 29
6.5
1/2
850 6350 341,000 109
690
PA" iy."
3000 39% 32% 13 29
6.5 :
1%
1150
8100 394,000
104
725
P/f iy."
Vane* with type of motor.
GRID UNIT HEATERS ARE NOT AFFECTED BY ELECTROLYTIC ACTION
No leaks--no breakdowns. Low maintenance expense. More air changes per hour. Positive "directed" heat.
Lower outlet temperatures. Larger air volume. Reduced fuel cost. Applicable to either low or high steam pressure lines.
Send for Bulletin on Units not listed above.
904
D. J. Murray Mfg. Co.
Air Conditioning
Unit Heaters and Coolers
GRID BLAST COILS
race view
side view
No Electrolysis to cause corrosion*
AU-cast aluminum heating sections. Only one type metal in contact with steam. Therefore, no electrolytic action is de veloped with its resultant corrosion to
cause leaks and breakdowns. Grid Blast Coils are different.
Cutaway section above shows why Grid Units are dif
ferent-- and how manifold is con nected with steam chamber--a simple and efficient con nection. Guaran teed for pressure up to 250 lb steam
pressure with high temperatures. Compact and oc cupies less space than other radia
tion of equal capa city. No leaks--no breakdowns. Low
maintenance ex
pense. No tortuous air passages; hence,
easy to clean at all times. Free area is
much greater than other types of coils.
Send for com plete data.
GRID BLAST COILS DATA
Model
B2I5 B3I5 B4I5 B5I5 B6I5 B220 B320 B420 B520 B620 B225 B325 B425 B525 B625 B230 B330 B430 B530 B630
Face Area Sq Ft 1.15 \.72 2.30 2.88 3.45 1.50 2.25 3.00 3.76 4.52 1.86 2.80 3.72 4.66 5.58 2.22 332 4.43 5.54 6.65
No. of Sections
Wide Two Three Four Five Six Two Three Four Five Six Two Three Four Five Six Two Three Four Five Six
A 9% 14% 19% 24% 29% 9% 14% 19% 24% 29% 9% 14% 19% 24% 29% 9% 14% 19% 24% 29%
Dimensions, Inches
B
ioy.
15% 20-% 25% 30%
ioy.
15% 20% 25% 30% 101/, 15% 20% 25% 30%
ioy.
15% 20% 25% 30%
c
16% 16% 16% 16% 16% 21% 21% 21% 21% 21% 26% 26% 26% 26% 26% 31% 31% 31% 31% 31%
D
20% 20% 20% 20% 201/2 25% 25% 25% 25% 25% 30% 301% 30% 30% 301% 35% 35% 35% '35% 35%
E
26% 26% 26% 261% 26% 31% 31% 31% 31% 31% 361% 36-% 361/2 36% 36% 41% 41% 41% 41% 41%
Weight Lb 127 184
, 236 . 288
346 181 223 293 358 424 194 / 267 343 443 512 207 294 390 478 566 .
905