Document 9JxXppRXrVVjg5J590OMv3KGp
202
CHAPTER'9
' 1951 Guide
Table 18. Combined Coefficients of Transmission ({/) of Pitched Roofs" and Horizontal Ceilings--Based on Ceiling Area6
Coefficient* are expreseed in Btu per {hour) (square foot of ceiling area) (Fahrenheit degree difference in temperature between the air on the two sides), and ere based on an outside wind velocity of 16 mph.
TYPE 0? ROOFING AND ROOF SHEATHING
CHUNG
(SENT/ (From
Wood Shctoms on Wood Strips*
Asphalt Shihules* or Roll Booitkq on Wood Sheathiho*
No Hoof Irwnlfttinn
(Baftezs Rmnsed) (Ur - 048)
fating Board on Under bide
of Bafters
(Ur - 002)
1 In. Insolating Board
on Under Side of Bafters
(Ur - 016)
No Hoof Inwilatinn (Bafters Kmwwtt (Ur - 053)
Ufa. Iranfating Board on Under Side
of Bafters (Ur " 0X3)
1 In. Inso-
fating Board on Under Side
of Bafters (Ur - 047)
F %
0l10
QJ1 <U2
4US 014
A
0085 0092 0099 Oil on
B
0.073 0078 0.082 0087 0091
C
0.066 0.07 0.074 0.078 0.081
D
0X87 0X94 OlO OH 041
E.
0074 0X79 0X83 0088 0X93
F
0067 0X71 0X75 0X79 0X83
19 20 21 22
23
015 OlO 017 018
019
012
018 018 014 014
0099 OlO
OlO ' OH
Oil
0X84
0087 0X90 0X93 0X95
042 043 . 043 014 045
0X97 OlO
OlO Oil
Oil
0X86 0X89 0X92
0095
0X93
24 25 28 27
28
020 021 092 083
024
005 015 016 0J6
017
0J1 QJ2 0J2
012
013
0X98
OlO OlO 040
Oil
015 016 017 017
018
012 012 012
042 013
OlO 040
Oil 041
0.11
29 30 81 82
33
025
029 027
028 029
017 018 018 019
019
018 018 013 014 014
041 Oil Oil 042
012
018 019 019
019 020
013 043
013 014
044
Oil 041
042 012
042
34 85 38 37
38
080
020 014
012 020
014 042 39
084
001
015
042 0X2
015
0.13 40
085
002 015
013 0X2
045 043 41
OS9
002
015
013
0X3
015
0.18 42
087
023
015 . 043
023
046
018 43
045 059 061 062 067
059
025 009
009 000
001 001
047 018 018 019 019
019
043 014 015 045 0.15
015
0X6 \ 0J0
0X1 0X1 0X3
0X3
017 049
019 019 0X0 0X0
044
015 045 016
046 046
44
45 40 47
48
49
* Calculations based on X pitch roof (n = 1.2) using the following formula:
UT X Uct
u"
U
Ut +
n
U = combined coefficient to be used with ceiling area. Ur d coefficient of transmission of the roof. Uoe 0 coefficient of transmission of the ceiling.
no the ratio of the area of the roof to the area of the ceiling.
* Use ceiling area (not roof area)' with these coefficients.
6 Coefficients in Columns D, B and F may be used with sufficient accuracy for tile, slate and rigid as bestos shingles on wood sheathing.
d Based on 1 z 4 in. strips spaced 2 in. apart.
4 Sheathing assumed If in. thick.
/ Values .of Uos to be used in this column may be selected! torn Table 12.
Q - "i
a
Heat Transmission Coefficients of Building-Materials
203
Table 19. Coefficients of Transmission (f7) of Solid Wood Doors
Coefficient! on expressed in Btu per (hour) (square foot) (Fahrenheit degree difference in temperature between the air on the two sides), and are based upon an outside wind velocity of 16 mph.
Nominal Thickness Inches
i u if
U
2 2i 3
Actual Thickness Inches
a
i*.
1A
if
if 2f 2f
Ua`b Exposed Door
0.69 0.59 0.52 0.51
0.46 0.38 0.33
u*.b With Glass Storm Door0
0.35 0.32 0.30 0.30
0.28 0.25 0.23
Computed using k = 1-15 for wood; / -- 1.65, fo = 6X and 1JO for air space.
b A U value of 0.85 may be used for single exposed doors containing thin wood panels or single panes of glass, and 0.39 for the same with glass storm doors,
e 50 percent glass and thin wood panels.
Table 20. Coefficients of Transmission ({/) of Windows, Skylights and Glass Block Walls
Coefficient, are expreseed sn Btu per (hour) (equare foot) (Fahrenheit degree difference in temperature between the air on the two sides), and are based upon the following outdoor conditions: 0 F air temperature, clear skies, no solar radiation
Section A--Vertical Glass Sheets
Number op Sheets
One
Two
Three
Air Space, inches............................ None U............................. 1.13
X
0.61
X
0.55
1 0.5* i
X
0.41 -
X
0.36
"1 0.34
Section B--Horizontal Glass Sheets (heat flow up) /
Number op Sheets
One
Two
Air Space, inches--...................... U.............................
None 1.40
Ye
0.70
H 0.66
1* 0.63
Section C--Walla op Hollow Glass Bloch Description
U
7} x 7} x 3f in. thick with glass fiber screen dividing the cavity........... ........ y...........
Section D--Approximate Application Factors for Windowb Multiply Flat Glass U Values by These Factors
0 60 0^56 0.48
Window Description
Single Glass
Percent* Glass
Factor
Double Glass*
Percent* Glass
Factor
Windows with Storm Sash*
Percent* Glass
Factor '
Sheets...............................................
100
1.00
100
1.00
Wood Sash....................................... Wood Sash......................................
80 60
0.90 0.80
80 60
0.95 0.85
80 GO
0.90
lioo* <Metal Sash......................................
80
1.00 ^
80
1.20
80
For 1 in. or greater. * Unit type double glazing (two lights or panes in same opening).
* Use with U values for two sheets with 1 in. air space. Based on area of exposed portion of sash; does not include frame or portions of sssh concealed by frame.
* For metal storm sash or metal sash with attached storm pane.