Document 9Jm6L1bXe6q9RvzopRVKwrJV5

-Monsanto MOM INAMI A l. ITJ^gSC J. J. Rodor DA1I March 21, 1972 WII.UC1 Call Report HI I l Ml NCI TO : C. PATON D, E. Roush 1460 D. W. Stegen 1070 H. R, Ford N. T. Johnson T. L. Oossage P. W. Oann COMPANY CONTACTED: DATE OF CALL: PERSONNEL CONTACTED: Shell Oil Company New Orleans, La, Friday, March 17 J. Frank Davis Summary At the time of our visit with Mr. Davis a month ago the Shell Oil people were not really convinced that they should convert their existing four or five Therminol SR systems to a non-PCB material. Since our last visit they did have an incident where the heat exchanger failed and they leaked Therminol SR into water which apparently is used for drinking water. This system Involves redistilling sea water to make drinking water and I am sure it has increased their interest in getting the PCB out of existence. The existing systems include a heat exchanger coil imbedded directly in the sea water. They are also designing four or five new platforms for fill nearing 1972 and all of these have been redesigned so that there will be a secondary heating sys tem to prevent direct contact of a heat transfer media with the drinking water. Mr. Davis also Ault sure that whichever fluid was selected for their present FR systems would have to be that material which most accurately fits the description of a non-toxic material. He did indicate to us that the fish kill data supplied by Dow on their Dowtherm Q did scare them and that if the Therminol 66 toxicity data appeared to be better they would very likely select it as the final fill. Because of the possibility of accidental leakage they were interested in receiving whatever data we could supply on detecting small amounts of Therminol 66 leakage into drinking water. In addition to that they wanted to know what the K value between water and Therminol 66 would be. The only other major concern to the Shell people was the compari son of Therminol 66 and Dowtherm G from a fire standpoint. On our previous visit they had been very impressed with the high autoignltion temperature of Dowtherm G and because of that we ran lab tests to evaluate the fluids under circumstances similar to their own. Vie ran tests simulating the leakage of Therminol 66 HONS 072M83 Shell , hew Orleans -2- or Dowtherm 3 Into a hot gas drain similar to what would happen In the exhaust from'their turbines. The spray of either Dowthcrm G or Thermlnol 66 Into a 900 gas drain did not result In fire and these figures Impressed Mr. Davis. We did caution, however, that our tests were not exactly like their own condi tions; however, it might give them some Idea of an accidental leakage. Action Required Roder to supply toxicity data for Thermlnol 66 as well as pos sible methods of detecting Thermlnol 66 leakage into water. Also confirm some of the results of our fire test data obtained at the fire test lab to both Mr. Davis and Ken Arnold. J. J. Roder ca MOMS 072484