Document 9JOjrYxGZGKxazQLMzwkG9LmD
July 2, 1992
DATE
ORIGINATOR /
SUBMITTED EMPLOYEE #
SAFETY ITEM TRACKING REPORT DEER PARK MANUFACTURING COMPLEX - OLEFINS BA
PLAINTIFFS EXHIBIT
SAFETY ITEM
SH-2357
PAGE 2
APPROVED OR
UNAPPROVED
........................
HUTS
APPROV.DATE STATUS PRIORITY NUMBER ORIGIN
RESPONSIBLE PERSON
7 DAY RESPONSE
DEPARTMENT: BD/HT/IP UNIT: CIPX OS-24-1992 ......................
05-28-1992 ......................
06-22-1992
UNIT: HT-II 01-01-1992
02-26-1992 ' 04-26-1992
AT PREP 1 ACCUMULATOR DECK, FOUND 2 INSPECTION PLUGS MISSING IN INSULATION ON V-IP-101, EXPOSING 2" HOLES OF ASBESTOS INSULATION. METAL BANDS ARE LOOSE AND INSULATION EXPOSED NEAR VESSEL SUPPORT. TAPED OVER HOLES AND WROTE HUTS TICKET.
A
CD 424961 APR
CREAMER, B.J.
YES
...........................................................................................................................................................
03-18-1992
STATION USED FOR COLLECTING FILTERED SEP COL BTMS SAMPLES NEEDS GROUND STRAP INSTALLED. STRAP WILL BE USED TO GROUND METAL CONTAINERS WHEN BULK SAMPLES ARE COLLECTED AT SAMPLE STATION.
A
A
B 436191 APR
MENDOZA, L.T.
YES
..........................................................................................................................................................
06-04-1992
__
FOUND STEP-LADDER WITHOUT NECESSARY INSPECTION TAG ATTACHED ANO HAD A BENT SUPPORT RUNG. LADDER REMOVED FROM UNIT AND TAGGED TO PREVENT USE UNTIL IT IS INSPECTED.
A 06-22-1992
AC
440057 APR
CREAMER, B.J.
YES
INSTALL HARD PIPE TO ELIMINATE TRIPPING HAZARD rROM FLEX HOSE ON V-OL-619, SOUR WATER LINE TO THE MDO.
A
NORTH SKIRT COVER ON V-OL-609 IS HISSING. WROTE MUTTS TICKET.
A 02-26-1992
BLK 8 AT RICH OIL COLLECTION PIT, NOTICED HIGH LEVEL IN PIT. PUMP HAD LOST PRIME AND WAS RUNNING -- HI LVL ALARM BROKEN, FLOAT LVL SWITCH BENT. PRIMED PUMP AND PUMPED DOWN SUMP. REPAIR ALARM AND FLOAT. NEED GOGO PUMP THAT WILL STAY ON PRIME.
A ...................... 04-27-1992
C I A
D ' 406254 APR
MENDOZA, L.T.
D 421367 APR
CREAMER, B.J.
P APR NGUYEN, T.H.
YES NO YES
STATUS: A = ACTIVE (Action In Progress) I = INACTIVE (Item Holding) C = COMPLETE (Action Complete) P = PROPOSED (Under Consideration)
PRIORITY: I = COMPLETE ASAP A = COMPLETE IN 7 DAYS B = COMPLETE IN 15 DAYS C = COMPLETE IN 60 DAYS D = PLANNED AS RESOURCES AVAILABLE P = PROJECT INITIATED S = SHUTDOWN ITEM
ORIGINATION: APR = ACCIDENT PREVENTION REPORT SUG = SAFETY SUGGESTION AUO = SAFETY AUDIT ITEM
DPMC-08637
LAM 002488
May 26, 1992
DATE
ORIGINATOR /
SUBMITTED EMPLOYEE #
SAFETY ITEM TRACKING REPORT DEER PARK MANUFACTURING COMPLEX - OLEFINS BA
PAGE 4
SAFETY ITEM
APPROVED OR UNAPPROVED MUTS
APPROV.OATE STATUS PRIORITY NUMBER ORIGIN
RESPONSIBLE PERSON
7 DAY RESPONSE
DEPARTMENT: BO/HT/IP UNIT: CIPX 04-13-1992 ......................
04-18-1992 ......................
05-24-1992
.. -
UNIT: HT-II 01-01-1992 -
01-22-1992
-
02-18-1992
INSULATION BLANKETS ON E-BO-921, 922, AND E-IP-601 ARE TOO HEAVY ANO ACKUARD TO BE SAFELY HANOLED BY ONE PERSON. WROTE MUTS TICKET TO HAVE SIZE OF BLANKETS REDUCED FOR EASIER ANO SAFER HANDLING.
A
A
C 429208 APR
B. J. CREAMER
YES
...........................................................................................................................................................
04-13-1992
PUMP P-134 SEAL FLUSH HOUSING DID NOT HAVE SAFE MEANS TO BE DEPRESSORED WHEN BEING
SERVICED, OPERATOR AND ENVIRONMENT BEING EXPOSED TO HYDROCARBON. CONNECTED HOUSING ORAIN TO MOO/ORIPS, USING SS TUBING, ALLOWING SAFE DEPRESSURE.
C APR
YES
...........................................................................................................................................................
--
AT PREP 1 ACCUMULATOR DECK, FOUND 2 INSPECTION PLUGS MISSING IN INSULATION ON V-IP-101, EXPOSING 2" HOLES OF ASBESTOS INSULATION. METAL BANDS ARE LOOSE ANO INSULATION EXPOSEO NEAR VESSEL SUPPORT. TAPED OVER HOLES AND WROTE MUTS TICKET.
A 03-18-1992
I
D 424961 APR
B. J. CREAMER
YES
INSTALL HARD PIPE TO ELIMINATE TRIPPING HAZARD FROM FLEX HOSE ON V-OL-619, SOUR WATER LINE TO THE MOO.
A
AT HT2 RX, K-0L-602, LINE RUNNING FROM WATER SAMPLE STATION WAS DISLOCATED AND ALLOWING OIL TO RUN TO STORM SEWER WHEN CHECKING OIL FOR WATER IN T-OL-600. CHANGED SOME PIPING AND RECTIFIED PROBLEM.
NORTH OF P-OL-609-B, FOUND EXTENSION LADOER LEANING AGAINST PIPE SUPPORT NOT TIED OFF. REMOVED LADDER AND FOUND IT OVER 2 YRS PAST DUE FOR INSPECTION. TAGGED "DO NOT OPERATE", WROTE MUTTS TICKET TO HAVE INSPECTED. PERIODIC AUOITS.
A 02-19-1992
A C
C
D 406254 APR
L. T. MENDOZA
YES
APR -
NO
C 419808 APR M. 0. CHAMBERLAIN
YES
STATUS: A = ACTIVE (Action In Progress) 1 = INACTIVE (Item Holding) C = COMPLETE (Action Conplete) P = PROPOSED (Under Consideration)
PRIORITY: I = COMPLETE ASAP A = COMPLETE IN 7 DAYS B = COMPLETE IN 15 DAYS C = COMPLETE IN 60 DAYS 0 = PLANNED AS RESOURCES AVAILABLE P = PROJECT INITIATED S = SHUTDOWN ITEM
ORIGINATION: APR - ACCIDENT PREVENTION REPORT SUG = SAFETY SUGGESTION AUO = SAFETY AUDIT ITEM
DPMC-08638
LAM 002489
Hay 26. 1992
DATE
ORIGINATOR /
SUBMITTED EMPLOYEE #
SAFETY ITEM TRACKING REPORT OEER PARK MANUFACTURING COMPLEX - OLEFINS BA
SAFETY ITEM
PAGE 14
APPROVED OR
UNAPPROVED
........................
HUTS
APPROV.DATE STATUS PRIORITY NUMBER ORIGIN
RESPONSIBLE PERSON
7 DAT RESPONSE
DEPARTMENT: LO-III UNIT: AUXILIARY 01-03-1992 ......................
01-08-1992 ......................
01-18-1992 .....................
01-22-1992 ......................
02-22-1992 ..................... 03-09-1992 .....................
WHILE INSPECTING BREATHING AIR EQUIPMENT, BOTTLE LOCATED EAST OF PERSONAL PROTECTIVE EQUIP LOCKER ON N. SIDE OF CWT FOUND EMPTY AND NO MASK IN CABINET. TOOK BOTTLE TO GET REFILLED AND REPLACED IN CA8INET WITH A MASK.
C
APR W. R. BARTZ
NO
........................................................................................................................................................
S. OF COOLING WATER AT GRADE, STEAM TRAP BLOWING TO ATMOS CAUSING A TRIPPING HAZARO ANO VISUAL PROBLEM. REASON FOR THIS IS CONOENSATE HEADER BLOCKED IN FOR SEVERAL MONTHS DUE TO PIPE LEAK, AWAITING REPAIRS. BARRICADED & NOTIFIED FOREMAN.
AA
APR T. H. BOARTZ
YES
...........................................................................................................................................................
._
ELEVATED FLARE PILOTS FLAMED OUT DUE TO CONDENSATE IN STEAM LINES TO FLARE TIP WHEN STEAM ADDED TO FLARE DURING UPSET. RELIT PILOTS WITH DIFFICULTY, NOTIFIED OPERATORS TO NOT INTENTIONALLY FLARE DURING OUTAGE. NEEDS INVESTIGATED.
C
APR C. J. LLOYD
NO
........................................................................................................................................................
AT P-U3-0950 SURFACE CONDENSER DECK, 200# STEAM LEAKING AT 1/2" UNION AT PRIMARY JET TO SURFACE CONDENSER. COULD HEAR IT, BUT COULDN'T SEE IT. ROPED AREA OFF AND WROTE HUTS TICKET TO REPAIR LEAK.
A
C A 409990 APR
D. J. FINE
YES
..........................................................................................................................................................
01-23-1992
AT 0P3 FLARE, THE WIND SKIRT POSSIBLY CONTAINS ASBESTOS. THERE ARE NO SIGNS INFORMING OF THE HAZARO IN THE AREA.
A CB
APR C. J. LLOYD
YES
..........................................................................................................................................................
02-24-1992
--
SAFETY SHOWER VALVE (S. OF CWT) DIFFICULT TO OPERATE, DOES NOT OPERATE IN SAME DIRECTION AS OTHER SAFETY SHOWERS. VALVE DIRECTION ANO DIFFICULTY OF OPERATION COULD CONTRIBUTE TO ESCALATION OF INJURY.
A
C 8 423758 APR
D. J. FINE
YES
..........................................................................................................................................................
STATUS: A = ACTIVE (Action In Progress) I = INACTIVE (Item Holding) C = COMPLETE (Action Complete) P = PROPOSED (Under Consideration)
PRIORITY: I = COMPLETE ASAP A = COMPLETE IN 7 DAYS B = COMPLETE IN 15 DAYS C = COMPLETE IN 60 DAYS 0 = PLANNED AS RESOURCES AVAILABLE P = PROJECT INITIATED S = SHUTDOWN ITEM
ORIGINATION: APR = ACCIDENT PREVENTION REPORT SUG = SAFETY SUGGESTION AUD = SAFETY AUDIT ITEM
DPMC-08639
LAM 002490