Document 9J3rxgR5apKwkOGwb6Z4nq9gR
160
Air Conditioning > cql>
Eutxu
1titCTROMODE Ottiiin Of COMMERCIAL CONTROLS CORPORATION
Complete line of ELECTRIC HEATING SYSTEMS for HOME-INDUSTRY-FARM ROCHESTER 3, NEW YORK
When you need advice in any field, you consult a specialist. Deciding on a heating system ts an important matter--one that
you do not undertake very often. Therefore, it is only natural
and in the course of wisdom, that you will look to a specialist in this field. For more than 30 years Electromode has devoted its research engineering and manufacturing facilities predomi
nantly to the design and production of electric space heating
equipment, and is one of the oldest in the business. The Safety Grid Heating Element is an Electromode feature. All electric
wires are insulated, embedded and completely sealed inside a finned aluminum casting. No exposed hot wires, no glowing
coils and no danger of fire, shock, or burn.This finned alumi num casting spreads the heat rapidly, resulting in higher effi ciency and greater economy. The built-in safety switch auto matically prevents overheating. The Safety Grid Heating
Element is guaranteed for 5 years against any defect in material or workmanship.
-For HOME and OFFICE
Fig. i
WALL-TYPE HEATERS
Electromode Wall-type Heaters are made
in models and capacities suitable for all
rise rooms, ranging from 1320 to 4000
watts, with built-in thermostat or man
ual control. Heat is fan-circulated at floor
level. Ail have automatic thermal safety
switch. The big room heaters have silver
grey finish and
be painted to match
decor. The small room or bathroom heat
ers are available in gleaming chrome or
white enamel and are used as complete
or auxiliary source of heat. See fig*. 1
and 2.
Fig. 3
Low-LEVEL
BASEBOARD HEATERS
Classically slim Low-LEVEL fits snugly to wall leaving more usable floor space. Spreads radiant warmth over cold walls without drafts and thermostatically con trolled by room thermostat. Customized fittings impart pleasing, flowing appear ance completely flexible to room size and design. Rugged steel cabinets, finished in golden bronze, can be made to blend with wall tones, if desired. Capacities from 550 to 2250 watts, 120, 240 and 208 volts. Easy to install. Only two assembly screws per unit. Snap-on front panel. No sepa rate end caps. Easy access to wireway. See fig. 3.
For INDUSTRY
Fig. 4
Fig. 5
FLOOR INSERT HEATERS
Mount flush with floor, causing no ob
struction in front of windows or in pas sageways. Install in wood or concrete. See fig. 4.
RADIANT CABLE HEAT
Coils of cable hidden in ceiling radiate clean heat downward. Each room tem perature controlled by separate thermo stat. Cables are a measured length of special insulated electric wires; water
proof ; non-corrosive. Used in plaster, drywall ceilings, or concrete floors. Magic Seal coating prevents streaks on ceiling See fig. 5.
Fig. 6
Fig. 7
UNIT HEATERS
Unit Heaters available in Suspension-type and Combination Portable and Suspen sion models. Capacities from 1500 to 45,000 watts. Fine for auxiliary warmth in hard-to-heat areas and for complete boating in outlying buildings. Adjustable louvers for directing fan-circulated heat into working zone- Thermostat control available OQ all models. See fig. 6 for Suspension and fig. 7 for Portable and Suspension. The Electromode Commer cial and Industrial heater is specifically designed for quick, comfortable, warmth in factory departments, offices, super markets and other areas where its quiet operation is an aset. It is easily portable, or it may be mounted on swivel-type brackets. 5KW--240 volts--angle or. 3 phase--17/175 Btu. See fig. 8.
Fig. 10
Fig. 11
Fig. 8
Fig. 9
l'A in. wide flange with in holes on
EXPLOSION-PROOF HEATERS
approximately 6 in. centers for mounting to air ducts. Complete wiring diagrams
Explosion-Proof heaters are specially en for special applications furnished on re
gineered for installation - in hazardous quest. See fig. 10.
areas where heat is required and danger Electromode Insert Duct Heater (fig.
of explosion exists. They conform to rigid safety specifications and are fully tested ana approved by Underwriters'
Laboratories for use in areas covered in
Class 1. Group D hrsardous locations.
Used in places where atmospheres contain
gasoline, petroleum, naphtha, solvent va
pors, natural gas and where flammable gases etc. are made or stored. Convec- .
tion type. Three models range from 2000:'; to 6000 watts. See fig. 9.
ID
Safety and endurance is inherent in its
construction. It was designed as a pack
age unit ready for easy installation. The
Safety-Grid heating element is your as
surance of complete protection against
fire, shock or bum. Safety switch auto
matically breaks the service to the heater
in the event of stoppage of air flow
.through the heater from any cause. It is
.an automatic reset type.
r?
BLAST COILS
. Engineering help gladly given. For
Consists of a bank of Electromode cast- more information,'-see your suppliet_or
aluminum beating elements mounted in' ' ' write. Dept. HVG-60, Electromode Divi
a 16 gauge formed steel frame having.a " sion of Commercial Controls Corporation.
Air Conditioning SjgjT--
INDUSTRIAL ENGINEERING AND EQUIPMENT COMPANY
22a Hanley Industrial Court, St. Louis (Brentwood) 17, Mo.
Electric Blast Coil Space Heaters
for Installation in Ducts and in Package Air Conditioners Total and Supplementary Heat
a 161
Package Units sized to specifications
SAVE! Design & layout work YOU J Field time
Commercial, industrial, institutional, residential and governmental installations are heated by these patented units.
lltey offer the following advantages: 1. COMPLETE UNIT, ready for simple field instal
lation, with all internal connections factory-made.
2. CUSTOM BUILT TO FIT your particular watt age, dimensional 'and circuiting requirements. Available with built-in relays.
3. THERMAL CUTOUT furnished with heater, dis connects power in case of air failure.
31,027 INSTALLATIONS to date
150 to 18,550,000 Watts
(Illustration at left)
Typical eui :ples include:
SUN-TIMES BUILDING, Chicago
CADILLAC MOTOR CO., Detroit
GENERAL FOODS CORP.,
White Plains ROCKEFELLER CENTER,
N. Y. City
LOYOLA
UNIVERSITY,
New Orleans
U. S. EMBASSY OFFICE,
Hongkong
I. MAGNIN DEPT. STORE,
Palo Alto, Calif.
ST. LAWRENCE SEAWAY,
U. S. and Canadian Sides
A FEW EXAMPLES OF USES 1. Primary source of heat
2. Booster, supplementary or standby auxiliary heat ing
3. Zone temperature control
4. Industrial applications (Example: for major oil refinery, seven pumping stations without attendants are heated by INDEECO blast coil heater installations)
Literature describes wide range of applications in de tail. More than 13,000 specifications on file.
INDEECO UNITS FOR PACKAGE AIR CONDI
TIONERS . Write for Bulletin E97P showing 704 sizes to fit 20 manufacturers' units.
WHITE FOR CATALOGS
CONSULTATION ON ANY PROJECT WITHOUT CHARGE
(listed by Underwriters' Laboratories under label service) INDEECO UNITS FOR DUCT INSTALLATION
Write for Bulletin E97U showing 422 sizes '