Document 9BEpLeM32Dbzez6mD0zN3LVD

TO: FROM: RE: November 9, 1992 W. F. Patient E. C. Martinelli L. M. Maresca D. P. Knechtges G. L. Rutman R. K. Hinderer M. Hross L. E. Larson W. W. Ban R. Gomez F. E. Krause D. Wilson M. M. Marshall U. MASS. LOWELL PROCESS EMISSIONS , % % A4/V The final report from U. Mass. Lowell to SPI was distributed to OHEIC (Occupational Health and Environmental Issues Committee) members at the November 6 meeting. Unfortunately, an extensive rewriting was required to the original submittal on July 18, which has taken several weeks. The report will be issued to SPI member companies by the end of the year with a cover letter to be drafted by David Sarvadi of Keller & Heckman containing several caveats. It should be noted that the data was obtained only after the processes reached steady state operation and the authors feel that "the emissions were at the peak off-gassing stage of the plastic production cycle" under the specific conditions described in the report. PVC products were provided by Geon: flexible PVC extrusion grade, rigid PVC injection grade and general purpose .. crystal PVC used in the thermoforming operation. Mass percentages of vapors collected during PVC processing are listed in tables X, p. 42 & 43; XII, p. 45; XIII, p. 46 and XIV, p. 47. As stated in the draft report, which was previously distributed, VCM and HCl were not detected and benzene was "present in very small amounts". The major ABS producers are very dissatisfied with this study and have funded any independent study by Battelle. A group of polyethylene producers plan to do the same and Dow is also considering commissioning Battelle to do a study on polystyrene. However, U. Mass. Lowell has the right to (and almost certainly will) publish this study. By copy of this memo, I am requesting Bob Burnett to have it reviewed by the appropriate Vinyl Institute Committees. Please do not release the report or any of the data outside of GVD until I give the "green light". cc: Bob Burnett 25285001 UMASS.MMM BF3990fS PROCESS EMISSIONS OF PLASTIC OPERATIONS Protocols for Source Sampling of Organic Gases Generated during Plastic Processes FINAL REPORT TO: The Society of the Plastics Industry, Inc BY: Nick R. Schott, Ph.D. Rafael Moure-Eraso, Ph.D'., CIH Michael J. Ellenbecker, Sc.D., CIH Jan Chang Huang. Ph.D. University of Massachusetts Lowell Work Environment Department Plastics Engineering Department July 18, 1992 ULRF Project No. 09-5381 BpG39907 TABLE OF CONTENTS Executive Summary I. Introduction A. Objectives and scope of the study B. Review of the Literature II. Materials and Methods A. Description of Machinery and Operating Conditions B. Description of Plastic Raw Materials Used C. Description of Collection and Analytical Methods 1. 2. 3. 4. 5. III. Results GC/MS Aldehydes Organic Acids Aerosols Hydrochloric Acid A. Organic Emissions Identified by Process B. Organic Emissions Identified by Polymer 1. Polystyrene 2. Polyethylene 3. Acrylonitrile-butadiene-styrene 4. Polyvinyl Chloride 5. Unsaturatcd Polyester C. Aerosol Emissions Identified by Polymer IV. Conclusions BFG39908 1 1 3 S 5 6 6 7 8 8 9 11 12 12 13 15 16 18 18 19 19 21 V. References VI. Tables VII. Appendixes Appendix A Appendix B Appendix C Appendix D Figures 1-8 (Sampling Locations) ESA Analysis/Detection limits Analytical Methods Calibration Methods 22 25 48 eoosszsz BFG39909 EXECUTIVE SUMMARY The objective of these experiments was to identify the best collection and analytical techniques available to conduct source sampling during plastics processing, and use them to prepare sampling protocols. Source samples of emissions from polymers in various processes were obtained in order to choose a set of target substances that would be representative of emissions in industrial settings. The study of previously published reports and the detection of emissions from seven plastic processes and five polymers permitted a reasonable basis to choose the target substances. The target substances recommended to be routinely sampled from five commercial grade plastic materials studied were : for polystyrene (PS): styrene, ethylbenzene, toluene and benzene; for polyethylene (PE): formaldehyde, formic acid and benzene; for acTvlonitrile-butadiene-stvrene (ABS): styrene, xylene, toluene and aciylonitrile; for polwinvl chloride (PVC): 'vinyl chloride, 'hydrochloric acid, benzene and toluene; and for unsaturated polyester bulk molding compound (BMC): styrene. Solid condensation aerosols were also measured in most experiments, therefore total aerosols were also recommended for routine sampling of process emissions. Criteria for selection of target substances were: positive identification, being present above ten times the detection limit of the analytical method and having regulatory interest (Note: compounds marked with an asterisk were sampled but not detected in these experiments but are nonetheless recommended for routine sampling). These initial procedures represent the necessary preliminary steps to be the basis for a complete protocol to quantify emissions to be used by the plastics industrial processor. The methods of collection were standard industrial hygiene sampling methods. Analysis was conducted by a commercial analytical laboratory accredited by the American Industrial Hygiene Association (AIHA) and the Commonwealth o.f Massachusetts. Samples were taken for seven basic plastic processes and one compounding operation as follows: Extrusion processes: strand ; sheet; blown film and extrusion coating, Injection molding. Thermoforming and Compression Molding, (including a compounding operation). The focus of the process emissions evaluated in this project is the emissions generated by the melting of the polymer per se. Emissions originated from additives (e.g., stabilizers, chain transfer additives, plasticizers and colorants) may appear in the results but are not the focus of this study. The methods described here are only suitable to evaluate emissions of thermoplastic processes where the polymers are melted in a normal steady state operation or the compounding and cure of the thermoset polyester. Non-steady state operations, such as purging may generate additional decomposition products of industrial hygiene interest. Their generation during plastic production should be evaluated but their collection and analysis were beyond the scope of this study. BFG39910 I. INTRODUCTION A. Objectives and Scope This report presents the results of the first phase of the development of a protocol to characterize emissions generated during plastic processes. The initial task in this project was to identify and perform quantitative analysis on selected organic vapors and measure gravimetrically aerosols generated from some plastic processes. The emissions were collected at the peak off-gassing stage of the plastic production cycle. The sampling strategy consisted of the collection of source sampling using industrial hygiene sampling collection equipment on industrial size plastics production machineiy at the University of Massachusetts Lowell. The collection and analytical methods described here could be generalized and applied to the identification and relative quantification of organic vapors and aerosols originated from a plastic melt. Once a broad spectrum of organic chemicals was identified and their relative concentrations determined, a decision was made to choose target substances suitable for quantification of emissions. These choices were based on two criteria; i.e., the relative amounts produced and the regulatory interest of the substances identified. This initial work is the necessary preliminary steps to be the basis for a complete protocol to quantify emissions to be used by the plastics processor. The methods of collection were standard industrial hygiene sampling methods. Analyses were conducted by a commercial analytical laboratory accredited by the American Industrial Hygiene Association (AIHA) and the Commonwealth of Massachusetts. The objective of this arrangement was to make these procedures available to any plastics processor on a routine basis. fiPG39911 1 25285004 Samples were taken for seven basic plastic processes and one compounding operation as follows: Extrusion processes: strand ; sheet; blown film and extrusion coating, Injection molding, Thermoforming and Compression Molding (including a compounding operation). Five commercially available plastic materials were used for different processes. They were: polystyrene (PS), polyethylene (PE) (high density polyethylene (HDPE) and linear low density polyethylene (LLDPE)), acrylonitrile-butadiene-styrene (ABS), polyvinyl chloride (PVC) and unsaturated polyester BMC (UP). A total of 30 sample sets were collected to identify organic chemicals through gas chromatography/mass spectrometry (GC/MS) methods. These identified a grand total of 76 quantifiable analytes (relative to a MS calibrating chemical). Two additional sample sets were collected to identify oxygenated compounds from PE extrusion. The analytical technique for these two last sets was High Pressure Liquid Chromatography /Ultra Violet (HPLC/UV). Eight quantifiable aldehydes and organic adds were identified. Aerosols generated from some processes were measured gravimetrically as total aerosols (15 samples) and benzene soluble aerosols (17 samples) for a total of 32 aerosol samples. The focus of this project was the emissions generated by the melting of the polymer per se. Emissions originated from additives (e.g_, stabilizers, chain transfer additives, plastidzers and colorants) may appear in the results but are not the focus of this study. Their generation is not discussed in this report, since their chemical nature and purpose was not identified to the researchers in any of the commercial grade polymers used in the experiments. The methods described here are suitable to evaluate emissions of thermoplastic processes where the polymers are melted in a normal steady state operation 2 BFG39912 or the compounding and cure of the thermoset polyester. Operations like purging (before and after steady state production) generate additional decomposition products (1). Emissions from thermal decomposition of additives, mold releases and decomposition products generated during purging and non-steady state conditions may be of particular industrial hygienic interest Their generation during plastic production operations should be evaluated but their collection and analysis were beyond the scope of this report B. Review of the Literature In the production of most plastics, polymers are melted and then shaped in processes such as extrusion, injection molding and thermoforming to obtain the desired final form. During processing, the hot polymer undergoes thermal degradation with the generation of various chemical species. The mechanisms of polymer degradation by heat have been identified as: random chain scission, elimination and de-polymerization (1). In the presence of air, some hot polymers emit oxygenated degradation products. Laboratory studies of mechanisms of thermal oxidation of some polymers have shown the production of low molecular weight (from one to three carbons) oxygenated forms, such as aldehydes, ketones and organic acids (2). De-polymerization has as its principal degradation product the monomer or monomers forming the polymer chain. A second mechanism of monomer generation is the release of un-reacted monomer trapped in the plastic material (1). The variables controlling the generation of emissions have been reported to be: a) the operating temperature; b) the rate of melted mass produced; c) the surface area of the 3 BFG39913 2528500S melted product; and d) the polymer residence time in the processing machine (3), (3). Very few systematic evaluations of thermoplastic process emissions are found in the literature where industrial size machinery has been evaluated. Studies in the U.S. are mostly laboratory evaluations (5) or studies of products of pyrolytic decomposition (6). Three U.S. field studies of thermoplastic emissions from styrene containing polymers were found in the literature (7), (8), (9). More extensive laboratory and field industrial hygiene evaluations of thermoplastic processes emissions were conducted in Scandinavian countries by the Swedish Work Environment Fund (4), (10), (11). The organic vapors were collected in charcoal tubes and analyzed mostly by GC (no MS) and High Pressure Liquid, Chromatography (HPLC). There is no detailed description of the plastic processing machinery (4). No information is provided on what specific process (e.g., injection molding, extrusion, etc.) generated what level of contaminant. The polymers used were commercial plastics of European origin (3). BFG39914 4 II. MATERIALS AND METHODS A Description of Machinery and Operating Conditions Sampling collection took place at the University of Massachusetts Lowell, Plastics and Composite Development Center (UMl^PCDC) located in the College of Engineering. UML-PCDC has complete processing machinery and testing materials for a vast selection of plastics. The processing equipment used was industrial size. Industrial quantities of technical grade materials and industrial production routines were employed. The UMLPCDC facilities are equivalent to a medium size industrial plastics production facility. The characteristics of the plastics process machinery used in this project are summarized in Table I. The materials used in each machine are also identified in the same Table. A description of each plastic used appears in Table n. Operating conditions, such as temperatures, flow rates and sample times are presented in the results section corresponding to each process and raw material (Tables V to XIII). As indicated in Table I, all the UML-PCDC laboratories are equipped with General Exhaust Ventilation (GEV). In addition, three pieces of equipment (the injection molding machine, the thermoforming press and the compounding mixer) have Local Exhaust Ventilation (LEV). The ventilation status of the machinery was not relevant to the sampling conducted in this project. The objective was to bypass any LEV or GEV system by placing sample probes within six inches of the molten polymer. 5 B. Description of Plastic Raw Material Used Commercially available plastics were used in the 30 sampling campaigns. Each plastic was used in the specific process for which it was recommended in the supplier's specifications. No quantitative information on additives was provided by the manufacturers. The plastics used by process appear in Table IL C Description of Sample Collection and Analytical Methods A typical experimental run took place on days when no other processes or machines were in operation at the UML-PCDC. Prior to the initial warmup period of a processing machine, a background sample was collected to identify any lingering laboratory air contamination around the processing area. The organic chemicals found in the background sample were subtracted from the final results of the process sample taken during steady state operations. Once the background laboratory air sample was collected, the process machine warmup was initiated. When the recommended operational temperatures, pressures and flow rates were stabilized, steady state was reached and the process sample was collected. It took from one to two hours, depending on the process and the polymer, before steady state was reached. Between 30 and 60 minutes after steady state was achieved, the sampling procedure was started (Precise sampling times and other aspects of sample collection are described in detail when specific methods are described below). This methodology was followed for all sampling campaigns where the analytical method was GC/MS, as well as when the analytes were aldehydes or organic acids. A detailed description of the procedures follows. 6 BFG39916 1. Sampling for Organic Vapors via GC/MS Analysis a) Sample Collection Different thermal desorption tubes were used depending on the analyte. Either a Carbotrap* 300 tube(for aromatics) or a Carbotrap 200 tube (for aliphatics), was used as the collection device to capture emissions generated in the processes studied. Figures 1 to 5 in Appendix A illustrate the sample probe locations for an injection molding experiment (Figure 1); for an extrusion paper coating experiment (Figure 2); for an extrusion blown film experiment (Figure 3); for a thermoforming experiment (Figure 4) and for a low pressure compression molding experiment (Figure S). Details of the Carbotrap tube are shown in Figure 6 (12). The sampling methodology is standard industrial hygiene practice used routinely by the Occupational Safety and Health Administration (OSHA), the Environmental Protection Agency (EPA) and the National Institute for Occupational Safety and Health (NIOSH) and is described in detail in readily available references (13). (* Note: Carbotrap is a trade name of Supelco a subsidiary of the Rohm and Haas Co.). 1) Sample Train The sample train consists of: 1) a Gillian Air Sampling Pump calibrated to draw air at 100 cm3/min. (calibration procedures appear in Appendix D); 2) Tygon tubing connecting the pump to the adsorption tube ; and 3) the Carbotrap tube (Carbotrap 300 or 200). The configuration is similar to Figure 7. Once the sample was taken (usually berwecn 5 and 6 liters of air) the tube was capped and sent to the laboratory for analysis. 7 BFG399J7 25285007 2) Sampling Procedure The sample collector (Carbotrap tube) is placed approximately 6 inches from where the molten plastic exits the process machine. The sample collectors were placed as close to the hot plastic as practicable, to assure capture of the plume of vapors emitted from the molten material. For details of each collection point see Figures 1 to 5. Three samples were collected for each experiment as follows: first, the sample of laboratory air collected one hour before the initiation of the melting process to assess the extent of contamination of the experimental area; second, the sample of the emission plume at least 30 minutes after the process was equilibrated at steady state for temperature, pressure and flow rates; third, a blank sample (unused sample tube) was shipped to the analytical laboratory with every sample set The analytical laboratory was not provided with information about which tubes were samples or blanks in order for them to be able to perform blind analysis. Other sampling details by process appear in the description of each experiment At the end of each sampling campaign, the emissions, background and blank samples were shipped to the laboratory where they were analyzed within 48 hours of collection as recommended by NIOSH (See NIOSH Method S 1501). Samples were kept under refrigeration (38F) while awaiting analysis. b) Analytical Procedure The Carbotrap tube is desorbed "ballistically" (from 35 C to 335 C in 16 seconds) in a Thermal Desorption Unit (Supelco TDU). The effluent is rapidly transferred to the GC column for separation. The GC column was a SUPELCOWAX 10 capillary. This column separates the organic chemicals in the sample (11). The MS procedure follows 8 BFG39918 immediately after the GC separation. The effluent is passed through a MS detector for identification and quantification of the organics in the sample. The MS quantification of the substances in the sample is made by comparison with a calibrating substance (e.g., benzene). Results are reported as mass equivalent of the calibrating chemical (14). Carbotrap 300 was used when aromatic organics emission were expected. This was the case for emissions from PS, ABS and polyester BMC A Carbotrap 200 column was used in situations where aliphatic or polar organics were expected (PE and PVC)(15). After sample collection the sampler was thermo-desorbed and analyzed by GC/MS as explained above. The analysis was performed in accordance with EPA Method 624 for Volatile Organics. Sensitivity and other data of the analytical method appear with the information supplied from the analytical laboratory in Appendix B. Complete copies of all the analytical methods appear in Appendix D. This analytical methodology was chosen because it permits complete desorption by heat and is sensitive to very low quantities of organic chemicals (13). 2. Sampling for Aldehydes Vapors from emissions are collected in the locations illustrated in Figures 1, 2 and 3. The collection device consisted of two impingers (bubblers) in series containing a solution of iso-octane and di-nitrophenyl hydrazone. Air was sampled through the bubblers for one hour at a rate of 1 L/min. The solution was then quantitatively evaluated by High Pressure Liquid Chromatography/Ultraviolet (HPLC/UV). The procedure used was EPA Method TO-S (Impinger Collection, HPLC/UV). This method was selected because it is specific for aldehydes and unlike GC/MS, the results are not reported as mass equivalents 9 BFG39919 25285008 of a surrogate compound. A complete copy of the method is included in Appendix D. 3. Sampling for Organic Acids Vapors from emissions were collected in the locations illustrated in Figures 1, 2, 3 and 4 using a silica gel adsorption tube. The sampling train was identical with the one used with Carbotrap tubes (see above). For analysis, the vapors were desorbed with de-ionized water and analyzed using HPLC. The column used was an Aminex HPX-87H ion exclusion column. The solvent was 0.01 H2S04 at 1 ml/min. This method was recommended by the H&ES Analytical Chemistry Laboratory of the Dow Chemical Company, Midland MI (16). This method is a variation of OSHA Method 28 for organic acids (see copy in Appendix D). 4. Sampling for Aerosols a) Total Aerosols The Total Aerosol designation in industrial hygiene practice include solid particles regardless of size, i.e., include respirable and not respirable sizes. They are collected in a filter with no size selective device preceding the sample train. Total aerosols were collected in the locations described in Figures 1, 2 and 3. The sampling train is described in Appendix A, Figure 8. The polystyrene cassette holds 37 mm diameter filters. The cassette was open for sampling to the laboratory air. The filter was a PVC 5 um pore membrane tared filter. Air was sampled for one hour at 2 L/min. After 24 hours of filter drying in a desiccator, the sample was weighed to 0.01 mg. The method used was NIOSH Method 0500. A copy of the procedure is included in Appendix D. 10 BFG39920 b) Benzene Soluble Aerosols This method was used for the purpose of differentiating organic from inorganic (dust) aerosols. Benzene soluble aerosols represent the organic vapors condensed in the particles collected. It is measured as the weight of the benzene soluble fraction of the Total Aerosols collected. Benzene Soluble Aerosols represent then, the sum of organic aerosols collected in a filter plus the condensed organics from the gaseous emissions that are soluble on benzene. Therefore, the weight of emissions collected by this method could, in some cases, be greater than the solid products of condensation collected by the method of Total Aerosols above. The procedure used for collecting Benzene Soluble Aerosols is identical to Total Aerosols, except that a Teflon (PTFE) 2 um size tared filter was used in a sealed cassette. For analysis, the filter was washed with pure benzene and the benzene soluble materials were determined gravimetrically. The method used was NIOSH Method 5023. A complete copy is included in Appendix D. This sample technique permits analysis for the presence of semi-volatile organic air compounds that could be present in the vapor or particle phases of thermal emissions. c) Lead Aerosols The same procedure was used for lead as outlined above for Total aerosols. The analytical method for lead analysis is Atomic Absorption Spectrophotometry (AA). This procedure to detect lead aerosols was used in processes where the raw material was PVC. The method used was NIOSH Method 7082. A copy is included in Appendix D. 11 BFG39921 ft. I iC O 'V P 'y 5. Sampling for Hydrochloric Acid Samples were collected on silica gel adsorbent tubes following the procedure outlined for organic acids. Sampling was for one hour at 100 cm3/min. The tubes are desorbed and analyzed by Ion Chromatography. The method used was NIOSH Method 7903. A copy is provided in Appendix D. BFG39922 12 III. RESULTS A. Organic Emissions Identified bv Process Seven sampling campaigns measured emissions from four different extrusion processes. They were: a) strand; b) sheet; c) blown film and d) extrusion paper coating. The polymers studied were PS, PE, ABS and PVC A list of the organic chemicals identified in these processes appears in Table m. Sampling procedures and methodology were described above. Diagrams of sampler locations appear in Appendix A. Two selection criteria for GC/MS analysis results were fulfilled by the chemicals identified in the table: first, the chemical had to be positively identified by the analytical method, and second, it had to be present in an amount ten times the detection limit This criteria was considered to be adequate since the background concentrations measured in the laboratory air were less than 1/10 the detection limit of the method (>0.001 ugm) and generally this amount identified the target substances of interest Aldehydes and organic acids in the PE experiments were identified by a different collection and analytical method, i.e., HPLC/UV (see Tables VII and VUI). The procedures in these experiments were quantitative and specific for aldehydes and organic acids. Table IV shows the emissions identified in three processes: a) injection molding; b) thermoforming and c) compression molding. Five polymers were studied: PS, PE, ABS, polyester BMC and PVC. Identical selection criteria apply for this table as applied to Table III. 13 BFG39923 B. Organic Emissions bv Polvmer Tables V to XI show the relative mass percentage of organic chemical emissions during the steady state processes studied and analyzed by GC/MS and HPLC/UV. The values in the tables were calculated by dividing the amount of each component by the total of all these identified components plus all other measured but un*identified components. Thus comparisons can be made within each experiment to examine the relative amounts of the various emissions. It was not possible to calculate any absolute amounts of emissions, per unit of polymer processed. This was because although the sample collected was representative of the emission stream, it did not contain the total emissions generated, or even a known proportion of the emissions. Therefore, it was not possible to compare the amount of emissions from one process, e.g., extrusion with another such as thermoforming. The relative emission percentages are calculated as the proportions by weight of the emission amounts of a compound in micrograms per kilogram of melted polymer going through the plastics process machine. Emission amounts were measured during the sampling time at steady state. The same sampling and analytical instruments and techniques (GC/MS) and (HPLC/UV) were used for each series of experiments with each polymer in the various plastic processes studied. The tables of results also present the highest temperature recorded during the process. The profile of operating temperatures typically varies between 5 and 20 F below the value reported in the Tables. However, it was considered that the critical parameter for the generation of emissions is the highest recorded temperature in the process. 14 BFG39924 It also should be observed that the mass of vapors collected during the sampling process is not a stoichiometric amount of the total mass of vapors emitted during a given process. The amounts collected during each sampling period were a fraction of the total emissions generated by the melted polymer during the process. The total emission plume was not collected, and the sample points chosen were but one of the sources of emissions (probably the highest) so that the total amount of emissions should be, by logic, higher that the amounts reported here. It is also important to point out that the percentage emissions are steady state values that ignored purging at the beginning and end of the processes and did not involve any upset conditions. It is known that in those circumstances, emissions increase and additional decomposition products from the plastic melt are expected (6). 1. Experiments with Polystyrene Table V summarizes the percentage organic emission of PS in four plastic processes. The analysis were conducted with GC/MS procedures. The organic vapors were collected with a Carbotrap 300 tube which is specifically recommended for identification of aromatic organic compounds. The procedures detailed in the methods sections were followed. Sample collection locations are described in Figures 1 to 5 in Appendix A. The highest emission detected in these experiments was styrene, followed by its dimers and trimers, as well as other aromatics. The only non-aromatic compounds detected were benzaldehyde and acetophenone. The footnotes of the table should be taken into consideration to interpret the results. The results of these experiment for polystyrene (Tables V, XII, XIII) confirm earlier European and U.S. studies where styrene and aerosols were the highest relative emissions 15 BFG39925 from thermal degradation of PS (7)(10). 2. Experiments with Polyethylene Three different sets of experiments were conducted to identify polyethylene (PE) emissions. In the first set, emissions were collected in Carbotrap tubes for desorption and analysis by GC/MS. The objective was to identify aliphatic compounds. The second set was planned to collect aldehydes and other oxygenated compounds. Emissions were collected in impingers containing di-nitro phenyl hydrazone and analyzed by HPLC/UV. This method is specific for aldehydes and ketones. The third set was planned to collect organic acids by collecting emissions in a silica gel tube, followed by HPLC/UV analysis, a) Organic Vapors Analyzed by GC/MS Table VI summarizes the percentage of relative organic emission of PE in three processes. The first column shows the emission percentages of an extrusion paper coating operation. Molten PE from an extruder was coated onto a moving paper roll. A preliminary experiment using a Carbotrap 300 collection tube emitted complex organics that were detected as "unknown aromatics" in the GC/MS analysis. These results were interpreted as contaminants generated from the paper being coated. It was also observed that the detection tube (Carbotrap 300), which is designed to collect aromatic organics, might have failed to capture aliphatic polar organics. It is known from the literature that these later compounds are emitted from molten PE (12). Based on these observations, the experiment was repeated extruding PE under coating conditions, but removing the paper roll and using a sample collector tube (Carbotrap 200) specifically designed to collect aliphatic organics. The objective of the 16 BFG39926 changes was twofold: to collect aliphatic organic emissions missed in the preliminary experiment in the Carbotrap 200 tube, and to avoid any contaminant originated from the paper in the coating operation. The results with the Carbotrap 200 tube identified a high percentage of aldehydes and other polar compounds absent in the preliminary experiment The results are shown in the first column of Table VI. These results prompted a second sampling campaign to quantitatively measure the aldehydes generated in PE extrusion for paper coating. The emissions evaluated from the two other PE processes (LLDPE Blown Film and HDPE Injection molding) were also collected in Carbotrap 200 tubes. The percentages of organics emitted appear in Table VI. The results of this experiment confirm earlier European studies where oxygenated compounds were the highest emissions from thermal degradation of PE (10). b) Aldehydes analyzed by HPLC/UV Table VTI summarizes the mass percentage of the emissions of aldehydes from the extrusion paper coating processes previously studied (LLDPE Paper Coating, Table VI, first column). Identical machines, materials, temperatures and sampling conditions as in the first experiment were used. The aldehydes in this table were individually determined with their specific calibration factor. HPLC/UV was used in this experiment to quantitatively measure each aldehyde generated from the PE melt. Results appear in Table VII. The high generation of formaldehyde confirms previous PE emission studies (4), (11). c) Organic Acids analyzed by HPLC/UV Table Vm summarizes the mass percentage of the emissions of organic acids 17 BFG39927 generated from the PE melt HPLC was used as the analytical technique, since it is more suited for organic acid detection (16). The analytical details appear in Appendix D. The only organic acid above the detection limit of the method was formic acid. It has been suggested (3) that some of the organic acids reported in previous studies (11) might be direct products of oxidation of the high levels of aldehyde emissions generated. 3. Experiments with Acrvlonitrile-butadiene-stvrcnc (ABS) Table IX summarizes the mass percentage of the relative emissions generated from three processes using ABS as the raw material. Since the emissions expected were aromatic organic chemicals, the collection tube was a Carbotrap 300 and vapors were analyzed by GC/MS, as described in the methods section. The principal emissions were styrene, acrylonitrile and some benzene derivatives. The presence of acrylonitrile is confirmed from previous reports (16). 4. Experiments with Polwinvl Chloride Table X summarizes the mass percentage of the relative emissions generated from three processes where PVC was used as raw material. Carbotrap 200 collection tubes were used since polar aliphatic compounds were expected. The organic vapors were analyzed by GC/MS in the usual manner described in the materials and methods section. Very small amounts of emissions were detected in these sets of experiments. Only the extrusion process generated significant emissions. However, is not clear if the emissions are from the polymer itself or the additives in the plastic Vinyl chloride was not detected under the conditions of these experiments. The detection limit for GC/MS was O.OOlugm. Samples were collected and analyzed for hydrochloric acid during the three 18 BFG39928 experiments. The collection media used was silica gel tubes and the analysis was performed by Ion Chromatography (NIOSH Method 7903). All the samples reported levels below the detection limits. Lead aerosol samples were also collected during the three experiments and analyzed by Atomic Absorption Spectrophotometry (AA) (NIOSH Method 7082). The samples were below detection limits of the method (>0.001 ugm). 5. Experiments with Compression Molding of (BMC1 Table XI summarizes the mass percentage of the relative emissions generated during mixing of materials and compression molding of a thermoset polyester formulation. The recipe included: a thermoset resin, styrene, calcium stearate and carbonate, glass fibers and catalyst. Carbotrap 300 tubes were used since aromatic organic emissions were expected. Hie collected organic vapors were analyzed by GC/MS. The process of MS analysis was changed slightly by the introduction of 3 additional calibrating substances for the MS quantification procedure (toluene, chlorobenzene, dicholoro ethylene, as well as the original calibrating substance: benzene). The only significant emission was styrene for both mixing and molding. c Aerosol .Emissions by Polymer 1. Total Aerosol Emissions Generation of polymer aerosol emissions (i.c., solid condensates of organic products) was observed in various processes with different polymers. The results are summarized in Table XII. The gravimetric sampling procedure (NIOSH Method 0500) used requires that the filters collected be desiccated for 24 hours previous to weighing. Therefore, any 19 BFG39929 volatiles captured in the filter evaporate before the weighing procedure. The generation of particulate emissions was confirmed from past experimental reports (3), (6), (9). PS, PE and ABS seem to generate measurable amounts of aerosols, as shown in the results. 2. Benzene Soluble Aerosols Table Xm summarizes the results of emissions of aerosols reported as the weight of organics extracted from the filter with benzene. The methodology of sampling and analysis permits the inclusion of condensate vapors in the gravimetric analysis in addition to the solid aerosols. Since the sampling cassettes for this collection and analysis method are sealed and there was not a desiccation process before weighing, the results in the table include both solid aerosols and condensate organics. The method used was NIOSH Method 5023. 20 BpG3993Q IV. CONCLUSIONS The principal objective of these experiments was to identify the best collection and analytical techniques available to conduct source sampling during plastics processing, and use them to prepare sampling protocols. Source samples of emissions from polymers in various processes were obtained in order to choose a set of target substances that would be representative of emissions in industrial settings. Preliminary sampling protocols for source emission identification were developed for five commercial plastics in seven plastics processes. The study of previously published reports and the detection of emissions from seven plastic processes and five polymers permitted a reasonable basis to choose the target substances. The target substances chosen from these experiments are identified in Table XIV. The focus of the project was to identify emissions generated by the melting of the polymers per se during steady state operations. Emissions originated by additives or during non-steady state operations are beyond the scope of this study. The continuation of this project will permit the development of specific sampling protocols that will allow for a more accurate measurement of the emissions of the target substances identified here. 21 BFG39931 tru s s V. REFERENCES BfG39932 22 V. REFERENCES E.M. Fettes, Chemical Reactions of Polymers, Wiley-Interscience Publishers. New York. 1964 A. Bevilacqua, E. English, and J. Gall, " Mechanisms of Polyethylene Oxidation." Journal of Polymer Science, 8: 1691-98, 1964 L.M. Westerberg, P. Pfaffli, and F. Sundholm," Detection of Free Radicals during Processing of Polyethylene and Polystyrene Plastics" Am. Ind. Hyg. Assoc. J. (43)54447, 1982 A. Hoff, S. Jacobsson, P. Pfaffli, A. Zihing and H. Frostling, " Degradation of Plastics", Scand. J. Work Environ. Health 8,Suppl. 2, 1-60, 1982 A.A. Grote, W.S. Kim and R.E. KupeL, " Establishing a Protocol from Laboratory Studies to be used in field Sampling Operations.". Am. Ind. Hyg. Assoc. J. (39), 8804, 1978 Boettner, G.L. Ball, B. Weiss, " Combustion Products from the Incineration of Plastics." University of Michigan for Office of Research and Monitoring. U.S. Environmental Protection Agency, U.S. EPA Research Grant N EC - 00386. Ann Arbor, MI, 1973 R.B.Seymour, C. McCormick, T. Martin and F. Williams," Test for the Presence of Styrene." P.41-2 Plastic Engineering, December 1978 P.G. Edgerlcy," A Study of Fume Evolution at Polymer Processing Temperatures." P.81-6, Plastics and Rubber Processing and Applications Vol. 1, No. 1, 1981 5. Mayer, R. Cook and M.Mattler. "Evaluation of Potential Employee Exposures while Molding Ignition Resistant Polystyrene.", p. 227-238. Journal of Cellular Plastics, July 1983 P. Pfaffli, " Thermodegradation of Styrene Containing Polymers" in Industrial Hazards of Plastics and Synthetic Elastomers, P. 203-13, Alan R. Liss, Inc. NY, NY. 1984 A. Hoff," Production Processing and Degradation Products of Polyethylene and Polypropylene." in Industrial Hazards of Plastic and Synthetic Elastomers." P. 299307, Alan R. Liss, Inc., NY, NY 1984 Anonymous, The Supelco Reporter (Rohm and Haas Co.). "Efficiently Monitor Toxic Airborne Compounds." Vol. VII, N 2, March 1988 23 BFG39933 13. S.V. Hering, Ed. Air Sampling Instruments for Evaluation of Atmospheric Contaminants. Gas and Vapor Sampler Collectors, p.421-449.7th. Edition. American Conference of Governmental Industrial Hygienists (ACGIH). Cincinnati. 1989. 14. Personal Communication. Paul Ulucci, Technical Director, ESA Laboratories, January 15, 1990. 15. Personal Communication. Bertsil B. Baker, E. I. Du Pont de Nemours & Company. April 17, 1990 16. Personal Communication. Patrick Murphy, The Dow Chemical Company, April 6, 1990 17. J. M. Trice and N. B. Galuzzo." Relationship of Airborne to Residual Acrylonitrile in Processing Equipment. " National Technical Conference - Plastics in Packaging and Acrylonitrile. Society of Plastics Engineers , Chicago, November 1978 18. S. A. Ness, Air Monitoring for Toxic Exposures: An Integrated Approach. Van Nostrand Reinhold, First Edition, New York, NY. 1991. BFG39934 24 VL TABLES 25 BFG39935 9T0SSZS2 Table I Characteristics of Plastics Process Machinery at University of Massachusetts-Lowell Plastics Engineering Department Process Extrusion1 Strand Die Extrusion1 Sheet Die Extrusion1 Paper-coating Extrusion1 Blown-Film Injection Molding 2 Thermoforming2 Compounding Machinery Welex Modem Plastic Mach. Modem Plastic Mach. Blown Film MPM Battenfeld Comet Lab. Thermoformer Baker Perkins Model 24:1 L/D 2 inch Dia. 15020 Die Width 15" 20:1 L/D 1.5inch Dia. VEXCL 028 BA 750 1424 Sheet Fed Sigma Blade Mixer Material PS, ABS, PVC PS, ABS PE (LLDPE) PE (LLDPE) PS, ABS, PE(HDPE), PVC PS, PVC, UP(BMC) UP(BMC) 1 2 PS PE LLDPE HDPE ABS PVC UP(BMC) All extruders are one stage. Machines equipped with local exhaust ventilation (LEV). The remaining machines under general exhaust ventilation (GEV). Polystyrene Polyethylene Linear low density polyethylene High density polyethylene Acrylonitrile-butadiene-styrene Polyvinyl chloride Unsaturated Polyester (Bulk Molding Compound) 26 BFG39936 Table II Plastic Raw Materials used in Process Emissions Experiments 1 Polystyrene | Polyethylene | ABS 1 PVC Extrusion Processes Strand General Purpose PS Extr. Grade Sheet General Purpose PS Extr. Grade ABS Extr. Grade Flexible PVC Extr. Grade ABS Extr. Grade Blown Film LLDPE Extr. Grade Paper Coat LLDPE Extr. Grade Injection Molding Thennoforming and Bulk Molding Injection Thermoforming Molding Mixing 1 Polystyrene Polyethylene ABS UP(BMC) Gen. Purp. PS Injec. Grade HDPE Injec. Grade ABS Injec. Grade PVC Notes on Table ll; Rigid PVC Injec. Grade Gen. Purp. PS Sheet' Gen. Purp. Crystal PVC High Temp/ UP-styrene High Temp/ | UP*styrene | 1 All the plastics are commercial chemical products containing a variety of processing aids, impact modifiers, fillers, plasticizers, lubricants and pigments. Some or all of these additives can volatilize during the melting process. = PS Sheet commercially available, not extruded atXJMass Lowell. * = Microwave cookware resin formulation. 25285017 27 b?G39937 TABLE m Selected' Process Emissions Identified by Air Sampling (Analysis by GC/MS, HPLC/UV, Ion Chromatography) | I PS PE Strand Styrene Styrene Dimer Ethylbenzene Toluene Benzaldehyde Acetophenone Benzene EXTRUSION PR OCESSES Sheet Styrene Styrene Dimer Styrene Trimer Ethylbenzene Toluene Benzaldehyde Acetophenone Benzene Blown Rim Extr. Coating Trimethylpentane Xylene Ethylhexane Trimethylhexane Octene Decape Benzene (Toluene)1 (Ethylbenzene)1 Formaldehyde* Acetaldehyde* Propional* Valeraldehyde* Acrolein* Formic Acid4 Benzene Xylene (3) Trimethyl- QH10. c6h14 (3) Alkanes Q, C* C,0 1 BFG39938 28 ABS Strand Acrylonitrile Styrene Toluene Cumene Benzaldehyde Propylbenzene Ethylbenzene SAN Dimer Styrene Dimer Phenol Subst. Nitrogenated compounds Sheet SAN Dimer Styrene Toluene Cumene Benzaldehyde Propylbenzene Xylene Acrylonitrile Styrene Dimer Phenol Subst. Nitrogenated compounds Blown Film Extr. Coating PVC Octadecane Nonanol Oxirene Styrene Cyclopropane Dimethylpentanol Xylenes Benzene Notes on table III = The compounds selected for this table were positively identified and were present at levels 10X the analytical detection limit f>0.001 ug for GC/MS1. Some of the organic chemicals could have been originated from the additives in the plastics used as raw materials. Unless otherwise noted, all compounds analyzed by GC/MS were collected in Carbotrap 300 or 200 adsorption tubes (all collection tubes were Carbotrap 300 except for Polyethylene/Paper Coating and PVC experiments where Carbotrap 200 was used). Collection was followed by thermo-desorption and the samples were analyzed by Gas Chromatography (GC) for separation and Mass Spectrometry (MS) for identification and relative quantification. The analytical procedure used was EPA Method 624. Exceptions to this method are listed below. + = Samples collected in two bubblers in series with a solution of DNPH and iso-octane. Analysis was performed by HPLC/UV. EPA Method TO-5. 29 BFG39939 &= 1= Notes on Table III Continuation; Samples collected on silica gel tubes and analyzed by HPLC/UV. Emissions of Toluene and Ethylbenzene in Blown film were unexplained, since they are not expected to be generated by the polymer. It is possible that could be generated by additives or laboratory contamination. PS PE = ABS = SAN * Polystyrene Polyethylene Acrylonitrile-butadiene-styrene Styrene-acrylonitrile co-polymer. BFG39940 30 TABLE IV Selected Process Emissions Identified by Air Sampling Analysis Performed by GC/MS INJECTION MC)LDING AND THERMOFORMINC PS PE ABS UP BMC PVC Injection Thermoforming Bulk Molding Compounding Xylene Isomers Ethylbenzene Toluene Styrene Toluene Benzaldehyde Xylene Isomers Tetramethylbutane Alkanes > Q> (Toluene)1 (Ethylbenzene)1 Styrene Xylene Toluene Ethylbenzene Tri-methyldecane Isomer Naphthalenecarbo-nitrile Styrene (CH3)4-butane (CH3)4-decane Benzaldehyde Propyl benzene Styrene Dimethylnonane Trimethyldecane Toluene Styrene Benzene Octanol Octacosane Dimethyl-undecane Ethylbenzene Xylenes Oxirene Toluene Ethyl-hexylacetic acid Benzaldehyde (CHj)j-decane Xylenes See notes on Table. IV on next page: 31 BFG39941 <3D O H- Notes on Table IV The compounds selected for this table were positively identified and were present at levels 10X the analytical detection limit f>0.001 ug for GC/MS1. Some of the organic compounds could have originated from the additives present in each plastic Unless otherwise noted, all the emissions were collected using a Carbotrap 300 tube. Collection was followed by thermo-desorption and the samples were analyzed by Gas Chromatography and Mass Spectrometry (GC/MS). The analytic procedures used were EPA Methods 624 and 8240. Carbotrap 300 tubes were used to collect organic vapors for PS and ABS. Carbotrap 200 tubes were used for PE and PVC Emissions of Toluene and Ethylbenzene in Injection Molding of PE were unexplained, since they are not expected to be generated by the polymer. It is possible that could be generated by additives or laboratory contamination. Polystyrene Polyethylene Aciylonitrile-butadiene-styrene Polyvinyl chloride Unsaturated polyester (Bulk Molding Compound) BpG39942 32 Table V Mass Percentages of Vapors Collected 1 Based on Amounts of Selected1 Emissions of Polystyrene Steady State Mat Flow-Rate (kg/hr) Highest Operating Temperature (F) Effluents Identified Styrene Styrene Dimer Styrene Trimer Ethylbenzene Propylbenzene Acetophenone Toluene Benzaldehyde Benzene Xylene Isomers Total % Selected1 Organics Quantified Extrusion Strand 10.4 445 % 50 38 ND 13 0.5 0.5 0.4 0.2 * ND 91 Extrusion Sheet 53 466 % 66 53 15 3 03 0.6 2 92 Inj. Mold. 4.0 440 .% 45.8 123 ND ND 16.7 ND 4.2 ND 4.2 16.7 100 % Not Quantified Organics 9 80 Thermfm. 2.6 _ 220 % 48 ND ND 1 ND ND 4 5 ND 2 60 40 Notes on Table V see next paee: 02OS82S& 33 BFG39943 Notes on Table V: The absolute amounts of organic emissions collected varied widely depending on the process. They ranged from total organics collected of 0.02 to 85 ugm depending on the circumstances of the different processes. Therefore it is not possible to compare the percentages generated between processes, i.e., between columns. 1 = The compounds selected for this table were positively identified and were present at levels 10X the analytical detection limit of the GC/MS (>0.001 ugm). Background organic vapors in the laboratory air were subtracted from the concentrations found in the sample. The collection tube for all experiments was Carbotrap 300. ND = a= Not Detected Identified but not accurate quantification could be made because of the very small amount of the organic vapor collected from the process. BFG39944 34 Table VI Mass Percentages of Vapors Collected Based on Amounts of Selected1 Emissions of Polyethylene | Steady State Material Flow-Rate (kg/hr) Highest Operating Temperature (F) LLDPE2 Extrusion 3.48 620 LLDPE Blown Film 2.48 HDPE Injec. Molding 2.64 500 450 Effluents Identified 1 Benzene | Tetra-Methylbutane Xylene Isomers Trimethyl-Pentane | Trimethyl-Hexane Ethyl-Hexane Decane Isomers Nonane Isomers Octane Isomers Unknown Alkanes Unknown Aldehydes Total % Selected1 Organics Quantified % %% ND 0.4 ND 2.1 ND 143 ND 9.4 ND 8.0 163 ND 5.7 63 ND ND 7.7 ND 14.8 43 ND 7.4 ND 17.1 33 ND 7.2 1.2 42.8 30.2 ND ND 92.6 85.8 100 | % Organics not Quantified | % Toluene3 | % Ethylbenzene3 7.4 14.2 0.0 ND 19.1 28.6 ND 17.5 14.3 For Notes on Table VI see next page- 35 BFG39g4s Notes on Table VI The compounds selected for this table were positively identified and were present at levels 10X the analytical detection limit of the GC/MS (>0.001 ugm). Background organic vapors in the laboratory air were substracted from the concentrations found in the sample. The collection tube for all experiments was Carbotrap 200. The procedure used was EPA Method 624. Polyethylene was extruded in a paper-coating operation but the paper was eliminated to avoid vapors that could be generated by the heating of the paper. Vapors were collected on a Carbotrap 200 tube. The tube was then thermo-desorbed and analyzed by GC/MS. Emissions of Toluene and Ethylbenzene in the Blown film and Injection Molding experiments were unexplained since they are not expected to be generated by the polymer. It is possible that these two compounds could have been generated by additives or laboratory contamination. Not Detected Toluene and Ethylbenzene included in the total % of quantified organic emissions Linear low density polyethylene High density polyethylene Identified but not accurate quantification could be made because of the very small amount of the organic vapor collected from the process. BFG39946 36 Table Vn Mass Percentages of Aldehydes1 from Extruded Polyethylene Steady State Material I Flow-Rate (kg/hr) Highest Operating 1 Temperature (F) Aldehydes Identified Formaldehyde Acetaldehyde Acrolein Propionaldehyde Valeraldehyde Total % Aldehydes+ Quantified LLDPE2 Extrusion Paper-Coating 3.48 617 % 27.50 30.00 6.00 12.50 24.00 100.00 LLDPE3 Extrusion No-Paper 3.48 620 % 44.00 34.66 534 16.00 ND 100.00 | | | | 1 | 1 | | Notes on Table VII 1 = Aldehydes were collected and analyzed by EPA Method TO-5. Vapors are collected in a solution of iso-octane and di-nitrophenyl hydrazone (DNPH) contained in two bubblers in series. The solution was analyzed by HPLC/UV. 2 = Polyethylene was extruded in a paper-coating operation. Vapors for aldehyde analysis were collected in two bubblers in series, as described above. The sample probe was placed at the point were the hot PE sheet met the paper roll near the exit of the die. ^ ZZoSfiZ 37 BFG39947 Notes on Table VTI (continuationV. 3 Polyethylene was extruded in a paper-coating operation in an identical set-up from the previous experiment but no paper was used. The sample probe was placed at the point were the hot PE sheet was exiting from the die. + Other aldehydes and ketones were also present at concentrations below the detection limits of the analytical method (v.g.: acetone, crotonaldehyde, isobutyraldehyde, methyl-ethyl-ketone and benzaldehyde. ND = Not Detected BFG39948 38 '1 Table VIII | Mass Percentages of Organic Acids1 from Extruded Polyethylene 8 Steady State Material | Flow-Rate (kg/hr) 1 Temperature (F) | Sampling Time (minutes) | Organic Adds Analyzed by HPLC | Acetic Acid J Formic Add 1 Acrylic Add Total % Organic 1 Acid Quantified Notes on Table VIII: LLDPE2 Extrusion 3.48 620 60 % ND 100 ND 100 1 Organic Acids were collected and analyzed by a modified OSHA-38 method for organic acids. Vapors were collected in a silica gel collection tube. The sample was then desorbed in a methanol solution and analyzed by HPLC/UV. 2 Polyethylene was extruded in a paper-coating operation whithout paper. + Other organic adds were also present at concentrations below the detection limits of the analytical method (e.g.: acetic add and acrylic add). ND Below the detection limits of the collection and analytical method. 39 ^pG39949 Table IX 1 Mass Percentages of Vapors Collected Based on Amounts of Selelected1 ABS Organic Emissions 1 | Steady State Mat | Flow-Rate (kg/hr) | Highest Operating | Temperature (F) | Effluents Identified Extrusion Strand 8.40 450 % Extrusion Sheet 622 450 % Inj. Mold 0.946 460 % I 1 | Acrylonitrile j Styrene 1 Styrene dimer | Unknown styrenic | SAN dimer f Alpha-methyl styrene | Xylene isomer Styrene/Xylene isomer C4-Benzene isomer Cs-Benzene isomer Ethyl Benzene Methyl(methyl-ethenyl) benzene isomer C,0HW isomer Substituted phenol Trimethyl bicydoheptanol Trimethyl dccane isomer 03 21.9 13 33 03 ND 0.5 ND ND 2.8 4.2 5.1 ND 23.5 3.4 ND ND 18.4 0.7 1.9 0.1 U 10.5 ND 6.9 1.1 ND ND 15.8 73 2.4 ND ND | IND ND ND ND ND 4.9 I35.2 IND IND 13.4 ND ND ND 1 ND 93 j 40 BFg399S0 Trimethyl bicyclo heptane 2,6-Bis (Dimethylethyl) methyl Phenol isomer Toluene Cumene Benzaldehyde | n-propyl benzene | Unknown nitrogen \ compound | Dichlorobenzene* Unknown C,6 Alcohol Total % Selected1 Oraganics Quantified % Organics not Identified 5.0 4.4 2.7 3.0 1.8 1.6 7.0 ND ND 92.4 7.6 3.0 ND 2.5 2.1 ND 1.0 5.4 ND 32 83.8 16.2 ND I ND 16.7 1.9 10.5 ND ND 9.6 ND 91.4 Notes on Table IX: 1 = The compounds selected for this table were positively identified and were present at levels 10X the analytical detection limit of the GC/MS (>0.001 ugm). Background organic vapors in the laboratory air were substracted from the concentrations found in the sample. The collection tube for all experiments was Carbotrap 300. The procedure used was EPA Method 624. ND = Not Detected Possibly generated from additives BFG39951 41 'C/T & K Table X Mass Percentages of Vapors Collected Based on Amounts of Selected1 PVC Organics I 1 Steady State Material | Flow Rate (kg/hr) | Highest Operating 1 Temperature (F) Effluents Identified Benzaldehyde Trimethyldecane Extrusion Strand 15 355 % nd nd Thermoforming Injection Molding 3.48 03 320 --400 % ..... % 1 62 nd 25 nd Acetic Acid-ethyl hexyl ester | Benzene j Ethylbenzene J Tetrachloroethylene | Toluene | Xylenes (total) | 1-Octanol Dccane,2,9-Dimethyl Undecane^, 10-Dimethyl | Octacosane Styrene Trichloroethylene Oxirane {(2-Ethyl Hexyl) oxy) Methyl)} l-Pentanol,2,3, Dimethyl nd 0.4 0.1 nd nd 0.1 nd nd nd nd 0.5 8.4 03 14.9 23 13 0.2 '' 17.4 3.7 nd nd nd nd nd nd 51.0 nd nd 5.4 nd 393 13 113 3.7 4.8 4.0 26.5 1.0 nd nd 42 BFG39952 J Cyclopropane, Pentanol | 1-Nonanol 5-Octadecane 9-Octadecane 1-Hexadecane | Total % Selected1 J Organics Quantified | % Organics not Identified 18.7 173 233 263 4.4 99.9 0.1 nd nd nd nd nd 99.7 03 nd nd nd nd nd 97.9 2.1 | Notes to Table X: 1 = The compounds selected for this table were positively identified and were present at levels 10X the analytical detection limit of the GC/MS ( >0.001 ugm). Background organic vapors in the laboratoiy air were substracted from the concentrations found in the sample. The collection tube used for all experiments was Carbotrap 300. nd = Not Detected = Compound identified but no accurate quantification could be made because of the very small amount of the organic vapor collected from the process. BFG39953 43 fO 05 C7f ft 01 Table XI I Mass Percentages of Vapors Collected 1 Based on Amounts of Selected1 Emissions of Polyesters (BMC) Material Flow (kg/Cycle) Highest Operating Temperature (F) | Effluents Identified Styrene Dimethyl-nonane Tri-methyl-decane Tetra-methyl-butane Isopropyl-benzene | Benzaldehyde Total % of Selected1 Organica Quantified % Organics not Quantified Notes on Table )ci: Compression Molding 130 270 % 973 nd 03 1.8 03 99.9 0.1 Material Mixing 130 270 % 91.8 2.2 1.6 nd nd nd 95.6 4.4 1 = The compounds selected for this table were positively identified and were present at levels 10X the analytical detection limit of the GC/MS (>0.001 ugm). Background organic vapors in the laboratory air were substracted from the concentrations found in the sample. The collection tube used for all experiments was Carbotrap 300. nd * Not Detected * = Compound identified but no accurate quantification could be made because of the very small amount of the organic vapor collected from the process. 44 BFG39954 Table Xn Aerosol Concentrations in mg/m3 (Total Particulate) Measured during Process Emissions Experiments Extrusion Processes Polystyrene Polyethylene ABS PVC Strand 14.00 - 7.66 ND Sheet 1.12 - 1.79 - Blow Film - 0.48 - - Paper Coating - 5.19 - * Injection Molding and Thermoforming Polystyrene Polyethylene ABS Polyester PVC Injection 0.41 ND ND - ND Thermoforming ND - ND BMC - ND - Mixing (BMC) - ND -1 Notes on Table XII: Samples were collected in a tared 37-mm, 5um PVC filter for one hour at 2 L/minute. The filters were weighed in an exact balance with a 0.01 mg sensitivity. This method is NIOSH Method 0500 . ND = Sampled but non detected. = Not sampled, experiment not run. IS a o ts 9$ 45 bFG39955 Table xm I Benzene Soluble Particulate Concentrations in mg/m3 1 Measured during Process Emissions Experiments Extrusion Processes Strand Sheet Blown Film Paper g Coating | Polystyrene Polyethylene | ABS 1 PVC 632 - 31.91 ND 0.08 - 2030 - - 538 - Injection Molding and Thennofcinning 736 - - Injection | Polystyrene J Polyethylene I ABS Polyester 0.17 ND ND - PVC ND Notes or Table Xlll; Thenmoforming ND - - ND ND BMC - ND - Mixing (BMC) - ND - Samples were collected in a tared 37-mm, 2um PTFE membrane filter for one hour at a sampling rate of 2 L/minute. The filters without desiccation were extracted with benzene and weighed in an exact balance with a 0.01 mg sensitivity. This is NIOSH Method 5023. ND = Sampled but not detected. = Not sampled, experiment not run. 46 BFG39956 Table XIV Recommended Target Substances Generated During Steady State Plastic Processes Experiments Plastic Polystyrene1 Polyethylene1 ABS1 PVC BMC Target Substance Styrene, Ethylbenzene, Toluene, Benzene3 Formaldehyde, Formic Acid Benzene3 Styrene, Xylene Toluene, Acrylonitrile Vinyl Chloride2, Hydrochloric Acid2 Benzene3, Toluene Styrene Note on Table XIV: 1 = Polystyrene, Acrylonitrile-butadiene-styrene (ABS) and Polyethylene generate solid condensation particulate during process melting. Total Particulate sampling is also recommended for these plastics as an indicator of emissions. 2 = Not detected in these experiments but recommended as target substance because of regulatory interest. 3 = Present in very small amounts but recommended as a target substance because of regulatory interest. 47 BFG39957 VII. APPENDIXES 48 BFG39958 APPENDIX A FIGURES 1-5 Sampling locations FIGURES 6-8 Sampling Trains for Organic Vapors and Aerosols bFG39959 APPENDIX B ESA Laboratories Methods Standards and Detection Limits BFG^960 APPENDIX C Analytical Methods for 1. Organic Vapors EPA - 624 (8240 A) 2. Aldehydes EPA - TO 5 3. Organic Acids OSHA - 38 (as Acrylic Acid) Dow Chemical Modifications 4. Aerosol Sampling Total Dust NIOSH - 0600 Benzene Soluble Particulate NIOSH - 5023 Lead NIOSH - 7082 5. Inorganic Acids Hydrochloric Acid NIOSH - 7903 BFG39961 Appendix D Calibration Sampling Equipment &FG39962 VII. APPENDIXES BFG39963 48 ocosqzsz APPENDIX A FIGURES 1-5 Sampling locations FIGURES 6-8 Sampling Trains for Organic Vapors and Aerosols BFG39964 (top view) (SIDE VIEW) WIRE GRID C300 'Li CTPV Total ;; sil::a MOLD CHAMi BER HOPPER RAW MATERIAL VENTILATION HOOD J SAMPLING PUMlPS I 4 3 2 1 MOLD HEATING ZONES FIGURE 1 SAMPLER LOCATION FOR INJECTION MOLDING EXPERIMENT 05 P bFG39965 C200 TUBE TOTAL DUST SILICA G ALDEHYDES FIGURE 2 B SAMPLER LOCATION FOR PAPER COATING <PE> EXPERIMENT Figures 2A and 2B . Sampler Locations for Extrusion Coat.*jrp Experiment BFG39966 Side View BFG39967 u3ri uoO2c. U21 UQ3 Cfl BFG390 ^ F ig u re 4. Sampler L o ca tio n s fo r Therm oform ing Experim ent UNSATURATED PDLY-ESTER LDW PRESSURE CDMPRESIDN MDLDING TDP VIEW Figure 5. Sampler Location for uacafttrated Polyester Experimen BFG39969 Q? 2 Co Co <a) o> cn > c 3O F VoJ Th 9M) 5C 2 < u <? vVtJ v-> JuC _a 3 -cQa f I (UwV Q BFG39970 Pump o o ro a. > 1 <> O Sample Train for Organic Vapor Measurements Figure 7 BFG39971 Jo I Q? Co Saopla crain for Tocal Ouse Msasursasnes Figure 8 BFG39972 APPENDIX B ESA Laboratories Methods Standards and Detection Limits BFG39973 8 05 8 Co 0? OVERVIEW OF ESA FABORATORIES ESA Laboratories (ESAL) is an industrial hygiene, environmental and clinical laboratory specializing in analyses directed toward the protection of the occupational workforce as well as the general public. As such, ESAL concentrates it's efforts on the analysis of samples which are collected by field personnel as pan of an overall program of health protection. ESAL specializes in the analysis of samples by anodic stripping voltammetry, atomic absorption, gas chromatography and gas chromatography/mass spectrometry. ESAL was formed in 1972 to initially demonstrate the feasibility of instrumentation manufactured by it's parent company, ESA, Inc. Initial work concentrated on the determination of lead in blood by anodic stripping voltammetry. The laboratory operation developed into a complete industrial hygiene laboratory offering services in the determination of trace metals, organic solvents and asbestos. In 1986, ESAL acquired a GC/MS and began expansion into the environmental analysis market Environmental services are limited to the analysis of trace metals, organic solvents, pesticides, PCB's, and volatile organics. ESAL is licensed by the U.S. Department of Health and Human Services (CDC) and a variety of state departments of public health to perform the analysis of biological fluids and tissues for trace metals. ESAL is accredited by the American Industrial Hygiene Association (organic solvents, metals, asbestos) and is certified by the Massachusetts DEQE and similar agencies in the states of New York, New Hampshire, Rhode Island, Connecticut and Maine for the analysis of environmental samples for trace metals, pesticides, PCB's and volatile organics (EPA 624). ESAL currently employs 15 people including laboratory technicians, chemists, and office staff. Analytical instrumentation includes anodic stripping voltammetry, atomic absorption spectrophotometry, UV/vis spectrophotometry, gas chromatography, liquid chromatography, ion chromatography and gas chromatography/mass spectrometry (equipped with purge Sc trap for volatile organics in soil and water, and thermal desorption for organics collected from air). ESAL has access to the facilities, capabilities and personnel of its parent company which is located in the same building. BFG39974 ESA LABORATORIES. INC. WIGGINS AVENUE. 8EDPORO. MA 017 U S A. 817-Z7S0100 TELECOPIER: (17) 278-8529 TELEX: 92}.,-. THERMAL DESORPTION GC/MS Compounds which can be trapped by Carbotrap 300 Tubes and detected by Thermal Desorption GC/MS: Acetophenone Acrylonitrile Allyl Chloride Benzene Benzyl Chloride Benzylamine Bromoform 2-Butanone n-Butanol n-Butylamine Carbon Tetrachloride 2-Chloropropene Chlorobenzene Chloroform Cumene Cyclohexanone p-Cresol 1,4-Dichlorobenzene 1,2-Dichloroethane 1,1-Dichloroethylene n-Decane Ethylbenzene 2-Ethoxyethylacetate n-Heptane 1-Hexane 4-Heptanone Methylene Chloride 2-Methyl-2-propanol Nitrobenzene n-Octane n-Pentanoic Acid n-Pentane Propionic Arid Phenol Tetrachloroethylene Toluene 1,1,1Trichloroethane Trichloroethylene Vinyl Chloride o,m,p-Xylene Compounds requiring highe desorption temperatures: Isopropylbenzene n-Propylbenzene n-Decane n-Butylbenzene Biphenyl n-Hexylbenzene n-Dodecane n-Octylbenzene n-Tetradecane BFG39975 POLYSTYRENE PROCESSING Target Substance Benzene Styrene Xylene Toluene Isopropyl benzene Ethyl benzene TLV-TWA 10 (PEL 1) 50 100 100 100 Analytical Method Collection on Carbotrap 300 Tubes. Determination by Thermal Desorption GC/MS, Detection limit (0.1/*g) 0.01 ppm for a 10 L sample Alternate Method: Charcoal Tube Collection, CS2 Desorption, GC/FTD detection (3/ig) 0.1 ppm for a 30 L sample. BFG39976 Low and High Density Polyethylene Processing Target Substance Etbene Ethane 2-Ethyl-hexane Aldehydes & Ketones formaldehyde* acetaldehyde Propionaldehyde (Propanal) TLV-TWA Analytical Method (PPM) Simple Asphyxiants (see TLY Book Pg 8) 1 (03) 100 EPA Method TO-5, Impinger method using 2,4-dinitrophenylhydrazine solution to derivatize the aldehydes and ketones, detection by HPLC/UV. Compounds detected include: Formaldehyde, Acetaldehyde, Acrolein, Acrolein, Propanal, Croton. aldehyde, Isobuty- raldehyde, MethylEthyl Ketone, Benzaldehyde, Hexanal, Detection Limit: 0.01 PPM for a 50 L sample A number of methods for Formaldehyde passive are available. BFG39977 Tareet Substance Acrylic Add Formic Add CO ACIDS TT V-TWA Analytical Method 10(2) 5 50 OSHA Method 28 2-XAD-8 absorbent tubes. Detection by HPLC/UV, Collection at 100 mL/Min Max of 24 L. Detection Limit: 0.02 PPM for a 24 L sample OSHA Method ID112, Impinger method using 0.01 N NaOH, detection by Ion Chromatography. Detection Limit: 0.01 PPM for a 100 L sample Indicator Tube BFG39978 Acrylonitrile/Butadiene/Stvrene (ABS1 Target Substance Acrylonitrile Butadiene Styrene Benzene Ethyl Benzene Phenol Cresol Phenol Cresol TLV-TWA (PPM) 2 10 100 10 (PEL 1) 100 5 5 5 5 Analytical Method Collection on Carbotrap 300 Tubes. Determination by GC/MS, Detection Limit: (0.01 /zg) 0.01 PPM for a 10 L sample Alternate Method: Charcoal tube Collection, CS2 Desorption, GC/FTD detection. Detection Limit: (3/zg) 0.1 PPM for a 30 L sample. OSHA Method 32, XAD-2 Tube. Detection by HPLC/UV, Detection limit: 0.1 PPM for a 24 L sample. BFG39979 Acrylonitrile/Butadiene/Stvrene fABSt fcont.1 Tareet Substance Hydrogen Cyanide Ammonia NO + N02 TLV-TWA 10 25 2 Analytical Method OSHA Method ID120, Filter cassette plus midget impinger with 0.1NNaOH Ion Specific Electrode or colorimetric detection. Detection Limit: 025 PPM for a 100L sample. Detector Tube OSHA ID164: Impinger (0.1N H2S04) Ion Specific Electrode or colorimetric detection. Detection limit: 0.25 PPM for a 100 L sample. Detector Tube BFG39980 Polwinvl Chloride (PVO Target Substance Vinyl Chloride Benzene Hydrogen Chloride TLV-TWA 5 10 (PEL 1) 5 Analytical Method Collection on Carbotrap 300 Tubes. Determination by Thermal Desorption GC/MS, Detection Limit: (0.1/zg) 0.01 PPM for 10 L sample. Alternate Method: Charcoal Tube Collection, CS2 Desorption, GC/FID detection. Detection Limit: Vinyl Chloride 020 PPM for a 5 L sample. OSHA File - Impinger method using 0.1 N NaOH. Ion Specific Electrode Detection, Detection Limit: 0.5 PPM for a 15 L sample. Alternate Method: NIOSH 7903, Silica Gel Tube (washed). Ion Chromatography detection. Detection Limit: 0.1 PPM for a 100 L sample. BFG39981 APPENDIX C Analytical Methods for 1. Organic Vapors EPA - 624 (8240 A) 2. Aldehydes EPA - TO 5 3. Organic Acids OSHA - 38 (as Acrylic Acid) Dow Chemical Modifications 4. Aerosol Sampling Total Dust NIOSH - 0600 Benzene Soluble Particulate NIOSH - 5023 Lead NIOSH - 7082 5. Inorganic Acids Hydrochloric Acid NIOSH - 7903 BFG39982 1. Organic Vapors EPA - 624 (8240A) BFG39983 The ESA Lab Note ESA Laboratories, Inc. 43 Wiggins Avenue Bedford, MA 01730 (617) 275*0100 Testing: "For A Healthier Environment" Determination of Volatile Organic Compounds (VOCs) in Air by Thermal Desorption/Gas Chromatography/Mass Spectrometry TD/GC/MS Introduction: This ESA Lab Note describes the procedure at ESAL to determine VOCs in air collected on solid sorbent tubes by TD/GC/MS. Sample Collection: Samples are collected on Carbotrap (TM) 300 thermal desorption tubes manufactured by Supelco. These are three part solid sorbent tubes capable of trapping and transfering a wide variety of organic compounds. A complete description of the Carbotrap 300 tube is found in Supelco GC Bulletin 849A and 846B (available from ESAL). Samples are collected at a flow rate of 100-200 ml/min for a maximum volume of 10-20 liters. Instrumentation: Thermal Desorption of the Carbotrap 300 tubes is performed on a Supelco Thermal Desorption Unit. The desorbed VOCs are transferred via a heated transfer line onto a 75 meter DB624 Meeabore Capillary Column at 5 degrees C. Separation and detection is accomplished with a Finmgan Model 5100 GC/MS/Data System. The system provides full scan electron impact spectra for identification and quantification of eluting compounds. Mass Spec Tuning: The Mass Spectrometer is tuned daily according to manufaturers instructions using perfluorotributylamine. This assures proper resolution and peak shape as well as correct ion abundances. BfG39984 ESA LABORATORIES. INC. *3 WIGGINS AVENUE. BEDFORD. MA 01730 USA 617 2780100 TELECOPIER: (817) 27S-5S29 TELEX. 923j-- The ESA Lab Note ESA Laboratories, Inc. 43 Wiggins Avenue Bedford, MA 01730 (617) 275-0100 Testing: *For A Healthier Environment* BFB Criteria: After tuning the Mass Spec system must pass the BFB (Bromofluorobenzene) performance criteria as specified in EPA Method 624 and 8240. This assures that the system is functioning properly for correct identification purposes. BFB Spectra, enhanced mass listing and ion abundance ratios are also submitted with each analytical batch to document proper instrument tuning each day. Initial Calibration: Once the GC/MS system is properly tuned according to BFB criteria, a five point calibration curve is run consisting of the solvents listed on the report form. Each calibration standard is thermally desorbed onto a Carbotrap 300 tube which is then run exactly like the samples. Thus standards and samples are run in a similar manner. Method Blanks are also run to ensure contamination free determination. Internal Standards/Surrogates To insure accurate results, each tube (samples, standards and blanks) are spiked with three internal standards and three surrogate standards. The GG/MS system uses the internal standards for both qualitative and quantitative analysis for those compounds listed on the report form. First, the instrument looks for each internal standard based on its Mass Spectra and retention time window. Once the internal standards are found, the instrument predicts the retention time of each compound. To be found the compound must meet retention time and mass spectral criteria. Once compounds have been identified their amount is based on the calibration curve. As a check on the overall procedure, three surrogate compounds are quantitated and the results reported on each report form. This checks the over-all operation of the method from thermal desorption thru GC separation and MS identification/quantitation. The procedure described above is basically what is done in EPA Methods 624 and 8240. BFG39985 <25 O *.< The ESA Lab Note ESA Laboratories, Inc. 43 Wiggins Avenue Bedford, MA 01730 Testing: "For A Healthier Environment" Daily Calibration: Every analytical sequence contains a continuing calibration check standard to insure instrument stability. Response factors from the daily check standard for each of the target compounds are calculated and compared to the mean response factors for each target from the initial five point calibration. Deviation from the initial calibration is calculated ana tabulated for each target compound (as %RSD) and submitted with each analytical batch. Method blanks are run daily to assure contamination free analyses. Individual Sample QA/QG Internal standard areas .'or each sample are compared to the Internal Standard areas of the check standard. Surrogate recoveries are calculated ana reported for each sample. The Mass Spectrum of all positive target compound hits are hardcopied. Non-target compounds are identified by comparison of their mass spectra with the NBS Mass Spectral Library of 42,000 + compounds. Along with the name of the compound, the scan number and the library fit parameter are also reported. A fit of 1000 is perfect; values above 800 are considered sufficient for a match. All this information is hardcopied from the MS system. Non-targets are quantitatec (estimated) versus the nearest internal standared. Some target compounds (particularly the gases at the beginning) must be estimated and searched for manually due to their poor response and difficult chromatography. Quality control charts are kept to monitor surrogate recovery on a continuing basis. Method Detection Limit: Approximately 0.002 ug for each target compound. BFG39986 ESA LABORATORIES, INC. 43 WIGGINS AVENUE BEDFORD, MA 01730 (617) 275-0100 FAX: (617) 275-5529 Page 1 ESAL BATCH#: ______ DATE RECEIVED: DATE ANALYZED DATE REPORTED: PO#/RELEASE: SAMPLE ID: __________________ ESAL SAMPLE#: THERMAL DESORPTION GC/MS QUANTITATIVE TARGET COMPOUND ANALYSIS - LEVEL I ANALYTE Benzene Chlorobenzene Ethylbenzene Styrene Toluene m/p-Xylene o-Xylene Bromoethane Carbon tetrachloride Chloroethane Chloroform Chloromethane Dlb romochlo rone thane 1,lDichloroethane 1,2-Dichloroethane RESULT ug ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ANALYTE 1,1-Dichloroethylene trans1,2-Dichloroethylene 1,2-Diehloropropane Methylene chloride 1,1,2,2-Tetrachloroethane Tetrachloroethylene 1,1,1-Trichloroethane 1,1,2-Trichloroethane Trichloroethylene Trichlorofluoromethane Vinyl Chloride RESULT g ND ND ND ND ND ND ND ND ND ND ND Acetone Carbon disulfide 2-Hexanone (MBK) 4-Methyl-2-pentanone (MIBK) ND ND ND ND Not Detected, Limit of Detection - 0.002ug- SURROGATE STANDARDS Expected Determined (Recovery NG NC (COST: $250.00] 1,2-Dichloroethane -D4 Toluene-D8 Bromofluorobenzene INTERNAL STANDARDS ----- - ------ ------ Expected Determined (Recovery NG NG ( 1,4-Difluorobenzene Chloro Benzene (D5) &FG39987 C/T ce QA O *0 (617) ESA LABORATORIES, INC. 43 WIGGINS AVENUE BEDFORD, MA 01730 275-0100 FAX: (617) 275-5529 ESAL BATCH#: Page 1 DATE RECEIVED DATE ANALYZED DATE REPORTED PO#/RELEASE: SAMPLE ID: ______________ ESAL SAMPLE#: ANALYTE THERMAL DESORPTION GC/MS QUANTITATIVE TARGET COMPOUND ANALYSIS - LEVEL II RESULT ug ANALYTE RESULT v. Benzene Bromobenzene n-Butylbenzene sec-Bucylbenzene cere-Bucylbenzene Chlorobenzene 2-Chlorotoluene 4-Chlorocoluene 1,2-Dichlorobenzene 1.3-Dichlorobenzene 1,4-Dichlorobenzene Ethylbenzene Isopropylbenzene p-Isopropyltoluene Naphthalene n-Propylbenzene Stysene Toluene 1,2,3-Trichlorobenzene 1,2,4-Trichlorobenzene 1,2,4-Trimethylbenzene 1,3,5-Trime chylbenzene m/p-Xylene o-Xylene Bromochloromechane Bromodichloromethane Bromoform Bromomethane Carbon tecrachloride ChloroeChane Chloroform Chloromechane Limit of Dececclon - 0.002ug SURROGATE STANDARDS ND Dibromochloromechane ND ND c-l,2-Dibromo-3-chloropropane ND ND c-l,2-Dibromo-3-chloropropane ND ND 1,2-Dibromoethane ND ND DibromomeChane ND ND 1,1-Dichloroechane ND ND 1,2-DIchloroe chane ND ND 1,1-Dichloroethylene ND ND cis-1,2-Dichloroethylene ND ND trans-1,2-dichloroethylene ND ND 1,2-Dichloropropane ND ND 1,3-Dichloropropane ND ND 2,2-Dichloropropane ND ND 1,1-Dichlorop topylene ND ND Hexachlorobutadiene ND ND Methylene chloride ND ND 1,1,1,2-Tecrachloroethane ND ND 1,1,2,2-Tetrachloroethane ND ND Tetrachloroethylene ND ND 1,1,1-Trichloroethane ND ND 1,1,2-Trichloroethane ND ND Trichloroechylene ND ND Trichlorofluoromechane ND ND 1,2,3-Trichloropropane ND ND Vinyl chloride ND Acecone ND 2-Butanone MEK ND ND ND ND Carbon disulfide ND ND 2Hexanone (MBK) ND ND 4-Methyl-2-pencanone (MIBK) ND ND Vinyl aceCaCe ND ND (COST: $325.00] Expected DeCermined %Recovery NC NG 1,2-Dichloroethane- D4 Toluene-D8 Bromofluorobenzene INTERNAL STANDARDS NG NC % 1,4-Dlfluorobenzene Chloro Benzene (D5) BFG39988 The ESA Lab Note ESA Laboratories, Inc. 43 Wiggins Avenue Bedford, MA 01730 (617) 275-0100 Testing: "For A Healthier Environment" Thermal Desorption GC/MS Quantitative Target Compound Analysis Level III Includes: 1. 2. 3. Quantitative Determination of Compounds listed in Level II NBS 42,000 + library search on every peak. Quantitation of non-target compounds by comparison to response factor of nearest Internal Standard. Cost: $400 per sample. 2S28SC-13 BFG39989 METHOD 8240A VOLATILE ORGANICS BY GAS CHROMATOGRAPHY/MASS SPECTROMFTRY (GC/MS): PACKED COLUMN TECHNIQUE 1.0 SCOPE AND APPLICATION 1.1 Method 8240 is used to determine volatile organic compounds in a variety of solid waste matrices. This method is applicable to nearly all types of samples, regardless of water content, including ground water, aqueous sludges, caustic liquors, acid liquors, waste solvents, oily wastes, mousses, tars, fibrous wastes, polymeric emulsions, filter cakes, spent carbons, spent catalysts, soils, and sediments. The following compounds can be determined by this method: - -- Analyte CAS No. Appropriate Technique Direct Purge-and-Trap Injection Acetone Acetonitrile Acrolein Acrylonitrile Allyl alcohol Allyl chloride Benzene Benzyl chloride Bromoacetone Bromochloromethane (I.S.) Bromodichioromethane 4-Bromofluorobenzene (surr.) Bromoform Bromomethane 2-Butanone Carbon disulfide Carbon tetrachloride Chlorobenzene Chlorobenzene-d, (I.S.) Chiorodibromomethane Chloroethane 2-Chloroethanol 2*Chloroethyl vinyl ether Chloroform Chioromethane Chloroprene 3-Chloropropionitrile 1,2-0ibromo-3-ch1oropropane 1,2-Dibromoethane Dibromomethane 1,4-0ichloro-2-butene Diehlorodif1uoromethane I,1-Dichloroethane 67-64-1 75-05-8 107-02-8 107-13-1 107-18-6 107-05-1 71-43-2 100-44-7 598-31-2 74-97-5 75-27-4 460-00-4 75-25-2 74-83-9 78-93-3 75-15-0 56-23-5 108-90-7 108-90-7 124-48-1 75-00-3 107-07-3 110-75-8 67-66-3 74-87-3 126-99-8 542-76-7 96-12-8 106-93-4 74-95-3 764-41-0 75-71-8 75-34-3 8240A - 1 PP a PP a PP a PP a PP a aa aa PP a PP a aa aa aa aa aa PP a PP a aa aa aa aa aa PP a aa aa aa a PC ND PC PP a aa aa PP a aa aa Revision 1 November 1990 bFG3999Q Analyte 1,2-Dichloroethane l,2-0ichloroethane-d4(surr.) 1,1-Dichloroethene trans-l,2-Dichloroethene 1,2-Dichloropropane l,3-Dichloro-2-propanol ci$-l,3-Dichloropropene trans-l,3-Oichloropropene 1,2:3,4-Diepoxybutane 1,4-0ifluorobenzene (I.S.) 1,4-Dioxane Epichlorohydrin Ethanol Ethylbenzene Ethylene oxide Ethyl methacrylate 2-Hexanone 2-Hydroxypropionitrile Iodomethane Isobutyl alcohol Malononitrile Methacrylonitrile Methylene chloride Methyl iodide Methyl methacrylate 4-Methyl-2-pentanone Pentachloroethane 2-Pi coline Propargyl alcohol b-Propiolactone Propionitrile n-Propyl amine Pyridine Styrene 1,1,1,2-Tetrachloroethane 1,1,2,2-Tetrachloroethane Tetrachloroethene Toluene To1uene-d# (surr.) 1,l,i-Trichioroethane 1,1,2-Trichloroethane Trichloroethene Trichi orofluoromethane 1,2,3-Trichloropropane Vinyl acetate Vinyl chloride Xylene (Total) CAS No. Appropriate Technique Purge-and-Trap Oirect Injection 107-06-2 107-06-2 75-35-4 156-60-5 78-87-5 96-23-1 10061-01-5 10061-02-6 1464-53-5 540-36-3 123-91-1 106-89-8 64-17-5 100-41-4 75-21-8 97-63-2 591-78-6 78-97-7 74-88-4 78-83-1 109-77-3 126-98-7 75-09-2 74-88-4 80-62-6 108-10-1 76-01-7 109-06-8 107-19-7 57-57-8 107-12-0 107-10-8 110-86-1 100-42-5 630-20-6 79-34-5 127-18-4 108-88-3 108-88-3 71-55-6 79-00-5 79-01-6 75-69-4 96-18-4 108-05-4 75-01-4 1330-20-7 8240A - 2 a a a a a PP a a a a PP i i a PP a PP NO a PP PP PP a a a PP i PP PP PP PP a i a a a a a a a a a a a a a a BFG3999J a a a a a a a a a a a a a a a a a pc a a a a a a pc a a a a a a a a a a a a a a a a a a a a Revision 1 November 1990 H -U S & Z2Z a Adequate response by this technique, b Chemical Abstract Services Registry Number, pp Poor purging efficiency resulting in high EQls. i Inappropriate technique for this analyte, pc Poor chromatographic behavior. 1.2 Method 8240 can be used to quantitate most volatile organic compounds that have boiling points below 200C and that are insoluble or slightly soluble in water. Volatile water-soluble compounds can be included in this analytical technique. However, for the more soluble compounds, quantitation limits are approximately ten times higher because of poor purging efficiency. The method is also limited to compounds that elute as sharp peaks from a GC column packed with graphitized carbon lightly coated with a carbowax. Such compounds include low molecular weight halogenated hydrocarbons, aromatics, ketones, nitriles, acetates, acrylates, ethers, and sulfides. See Table 1 for a list of compounds, retention times, and their characteristic ions that have been evaluated on a purge-and-trap GC/MS system. 1.3 The estimated quantitation limit (EQL) of Method 8240 for an individual compound is approximately 5 jig/Kg (wet weight) for soil/sediment samples, 0.5 mg/Kg (wet weight) for wastes, and 5 ng/L for ground water (see Table 2). EQls will be proportionately higher for sample extracts and samples that require dilution or reduced sample size to avoid saturation of the detector. 1.4 Method 8240 is based upon a purge-and-trap, gas chromatographic/mass spectrometric (GC/MS) procedure. This method is restricted to use by, or under the supervision of, analysts experienced in the use of purge-and-trap systems and gas chromatograph/mass spectrometers, and skilled in the interpretation of mass spectra and their use as a quantitative tool. 1.5 To increase purging efficiencies of acrylonitrile and acrolein, refer to Methods 5030 and 8030 for proper purge-and-trap conditions. 2.0 SUMMARY OF METHOO 2.1 The volatile compounds are introduced into the gas chromatograph by the purge-and-trap method or by direct injection (in limited applications). The components are separated via the gas chromatograph and detected using a mass spectrometer, which is used to provide both qualitative and quantitative information. The chromatographic conditions, as well as typical mass spectrometer operating parameters, are given. 2.2 If the above sample introduction techniques are not applicable, a portion of the sample is dispersed in methanol to dissolve the volatile organic constituents. A portion of the methanolic solution is combined with organicfree reagent water in a specially designed purging chamber. It is then analyzed by purge-and-trap GC/MS following the normal water method. 2.3 The purge-and-trap process - An inert gas is bubbled through the solution at ambient temperature, and the volatile components are efficiently transferred from the aqueous phase to the vapor phase. The vapor is swept 8240A - 3 Revision 1 November 1990 BFG39992 through a sorbent column where the volatile components are trapped. After purging is completed, the sorbent column is heated and backflushed with inert gas to desorb the components onto a gas chromatographic column. The gas chromatographic column is heated to elute the components, which are detected with a mass spectrometer. 3.0 INTERFERENCES 3.1 Interferences purged or coextracted from the samples will vary considerably from source to source, depending upon the particular sample or extract being tested. The analytical system, however, should be checked to ensure freedom from interferences, under the analysis conditions, by analyzing method blanks. 3.2 Samples can be contaminated by diffusion of volatile organics (particularly methylene chloride and fluorocarbons) through the septum seal into the sample during shipment and storage. A trip blank, prepared from organicfree reagent water and carried through the sampling and handling protocol, can serve as a check on such contamination. 3.3 Cross contamination can occur whenever high-concentration and low- concentration samples are analyzed sequentially. Whenever an unusually concentrated sample is analyzed, it should be followed by the analysis of organic-iyjjap^hgagefft water to check for cross contamination. The purge-and-trap system may require extensive bake-out and cleaning after a high-concentration sample. " - 3.4 The laboratory where volatile analysis is performed should be completely free of solvents. 3.5 Impurities in the purge gas and from organic compounds out-gassing from the plumbing ahead of the trap account for the majority of contamination problems. The analytical system must be demonstrated to be free from contamination under the conditions of the analysis by running calibration and reagent blanks. The use of non-TFE plastic coating, non-TFE thread sealants, or flow controllers with rubber components in the purging device should be avoided. 4.0 APPARATUS ANO MATERIALS 4.1 Microsyringes - 10 mL. 25 nl, 100 jil, 250 ul, 500 pi, and 1,000 pi. These syringes should be equipped with a 20 gauge (0.006 in. ID) needle having a length sufficient to extend from the sample inlet to within 1 cm of the glass frit in the purging device. The needle length will depend upon the dimensions of the purging device employed. 4.2 Syringe valve - Two-way, with Luer ends (three each), if applicable to the purging device. 4.3 Syringe - 5 ml, gas-tight with shutoff valve. Z l'O Z & Z Z Z 8240A - 4 BFG39993 Revision 1 November 1990 4.4 Balances * Analytical, 0.0001 g, and top-loading, 0.1 g. 4.5 Glass scintillation vials - 20 ml, with screw caps and Teflon liners or glass culture tubes with a screw cap and Teflon liner. 4.6 Volumetric flasks, Class A - 10 mL and 100 mL, with ground-glass stoppers. 4.7 Vials - 2 mL, for GC autosampler. 4.8 Spatula Stainless steel. 4.9 Disposable pipets - Pasteur. 4.10 Heater or heated oil bath - Should be capable of maintaining the purging chamber to within 1C over the temperature range of ambient to 100C. 4.11 Purge-and*trap device - The purge-and-trap device consists of three separate pieces of equipment: the sample purger, the trap, and the desorber. Several complete devices are commercially available. 4.11.1 The recommended purging chamber is designed to accept 5 ml samples with a water column at least 3 cm deep. The gaseous headspace between the water column and the trap must have a total volume of less than IS mL. The purge gas must pass through the water column as finely divided bubbles with a diameter of less than 3 mm at the origin. The purge gas must be introduced no more than 5 mm from the base of the water column. The sample purger, illustrated in Figure 1, meets these design criteria. Alternate sample purge devices may be utilized, provided equivalent performance is demonstrated. 4.11.2 The trap must be at least 25 cm long and have an inside diameter of at least 0.105 in. Starting from the inlet, the trap must contain the following amounts of adsorbents: 1/3 of 2,6-diphenylene oxide polymer, 1/3 of silica gel, and 1/3 of coconut charcoal. It is recommended that 1.0 cm of methyl silicone coated packing be inserted at the inlet to extend the life of the trap (see Figure 2). If it is not necessary to analyze for dichlorodifluoromethane or other fluorocarbons of similar volatility, the charcoal can be eliminated and the polymer increased to fill 2/3 of the trap. If only compounds boiling above 35C are to be analyzed, both the silica gel and charcoal can be eliminated and the polymer increased to fill the entire trap. Before initial use, the trap should be conditioned overnight at 180C by backflushing with an inert gas flow of at least 20 mL/min. Vent the trap effluent to the room, not to the analytical column. Prior to daily use, the trap should be conditioned for 10 minutes at 180C with backflushing. The trap may be vented to the analytical column during daily conditioning. However, the column must be run through the temperature program prior to analysis of samples. 4.11.3 The desorber should be capable of rapidly heating the trap to 180C for desorption. The polymer section of the trap should not be heated higher than 180C, and the remaining sections should not exceed 220C during bake out mode. The desorber design illustrated in Figure 2 meets these criteria. 8240A - 5 Revision 1 November 1990 BFG39994 4.11.4 The purge-and-trap device may be assembled as a separate unit or may be coupled to a gas chromatograph, as shown in Figures 3 and 4. 4.11.5 Trap Packing Materials 4.11.5.1 2,6-Oiphenylene oxide polymer - 60/80 mesh, chromatographic grade (Tenax GC or equivalent). 4.11.5.2 Methyl si 1icone packing - OV-1 (3%) on Chromosorb-W, 60/80 mesh or equivalent. 4.11.5.3 Silica gel * 35/60 mesh, Davison, grade 15 or equivalent. 4.11.5.4 Coconut charcoal - Prepare from Barnebey Cheney, CA-580-26, lot #M-2649, by crushing through 26 mesh screen (or equivalent). 4.12 Gas chromatograph/mass spectrometer system 4.12.1 Gas chromatograph - An analytical system complete with a temperature programmable gas chromatograph and all required accessories including syringes, analytical columns, and gases. 4.12.2 Column - 6 ft x 0.1 in. ID glass, packed with 1% SP-1000 on Carbopack-B (60/80 mesh) or equivalent. 4.12.3 Mass spectrometer - Capable of scanning from 35-260 amu every 3 seconds or less, using 70 volts (nominal) electron energy in the electron impact mode and producing a mass spectrum that meets all the criteria in Table 3 when 50 ng of 4-bromofluorobenzene (BFB) are injected through the gas chromatograph inlet. 4.12.4 GC/MS interface - Any GC-to-MS interface that gives acceptable calibration points at 50 ng or'less per injection for each of the analytes and achieves all acceptable performance criteria (see Table 3) may be used. GC-to-MS interfaces constructed entirely of glass or of glasslined materials are recommended. Glass can be deactivated by silanizing with dichlorodimethylsilane. 4.12.5 Data system - A computer system that allows the continuous acquisition and storage on machine readable media of all mass spectra obtained throughout the duration of the chromatographic program must be interfaced to the mass spectrometer. The computer must have software that allows searching any GC/MS data file for ions of a specified mass and plotting such ion abundances versus time or scan number. This type of plot is defined as an Extracted Ion Current Profile (EICP). Software must also be available that allows integrating the abundances in any EICP between specified time or scan number limits. The most recent version of the EPA/NIST Mass Spectral Library should also be available. 05 8240A - 6 BFG39995 Revision 1 o: November 1990 5.0 REAGENTS 5.1 Reagent grade chemicals shall be used in all tests. U indicated, it is intended that all reagents shall conform to the of the Committee on Analytical Reagents of the American Chemical such specifications are available. Other grades may be used, first ascertained that the reagent is of sufficiently high purit use without lessening the accuracy of the determination. 5.2 Organic-free reagent water - All references to water refer to organic-free reagent water, as defined in Chapter One. 5.3 Stock solutions - Stock solutions may be prepared fro materials or purchased as certified solutions. Prepare stock sta in methanol, using assayed liquids or gases, as appropriate. 5.3.1 Place about 9.8 ml of methanol in a 10 ml tare stoppered volumetric flask. Allow the flask to stand, ui about 10 minutes or until all alcohol wetted surfaces hav the flask to the nearest 0.0001 g. 5.3.2 Add the assayed reference material, as descr 5.3.2.1 Liquids - Using a 100 pL syringe, two or more drops of assayed reference material to reweigh. The liquid must fall directly into the contacting the neck of the flask. 5.3.2.2 Gases - To prepare standards for any boil below 30#C (e.g. bromomethane, chloroethane, ch vinyl chloride), fill a 5 ml vaived gas-tight sy reference standard to the 5.0 mL mark. Lower the above the methanol meniscus. Slowly introduce the ref above the surface of the liquid. The heavy gas will r in the methanol. Standards may also he prepared by bottle equipped with a Hamilton Lecture Bottle S< Attach Teflon tubing to the side-arm relief valve and stream of gas into the methanol meniscus. 5.3.3 Reweigh, dilute to volume, stopper, and then r the flask several times. Calculate the concentration in m liter (mg/L) from the net gain in weight. When compound puri to be 96% or greater, the weight may be used without c calculate the concentration of the stock standard. Commerci stock standards may be used at any concentration if they are the manufacturer or by an independent source. 5.3.4 Transfer the stock standard solution into . screw cap bottle. Store, with minimal headspace, at -1C protect from light. 5.3.5 Prepare fresh standards every two months for compounds such as 2-chloroethylvinyl ether and styrene 8240A - 7 BFG39996 prepared more frequently. All other standards must be replaced after six months. Both gas and liquid standards must be monitored closely by comparison to the initial calibration curve and by comparison to QC check standards. It may be necessary to replace the standards more frequently if either check exceeds a 25% difference. 5.4 Secondary dilution standards - Using stock standard solutions, prepare in methanol, secondary dilution standards containing the compounds of interest, either singly or mixed together. Secondary dilution standards must be stored with minimal headspace and should be checked frequently for signs of degradation or evaporation, especially just prior to preparing calibration standards from them. 5.5 Surrogate standards - The surrogates recommended are to1uene*d9, 4-bromofluorobenzene, and 1,2-dichloroethane-d4. Other compounds may be used as surrogates, depending upon the analysis requirements. A stock surrogate solution in methanol should be prepared as described in Section 5.3, and a surrogate standard spiking solution should be prepared from the stock at a concentration of 250 fig/IQ mL in methanol. Each sample undergoing GC/MS analysis must be spiked with 10 of the surrogate spiking solution prior to analysis. 5.6 Internal standards - The recommended internal standards are bromochloromethane, 1,4-difluorobenzene, and chlorobenzene-d,. Other compounds may be used as internal standards as long as they have retention times similar to the compounds being detected by GC/MS. Prepare internal standard stock and secondary dilution standards in methanol using the procedures described in Sections 5.3 and 5.4. It is recommended that the secondary dilution standard should be prepared at a concentration of 25 mg/L of each internal standard compound. Addition of 10 *iL of this standard to 5.0 mL of sample or calibration standard would be the equivalent of 50 ng/l. 5.7 4-Bromofluorobenzene (BFB) standard - A standard solution containing 25 ng/^L of BFB in methanol should be prepared.-. 5.8 Calibration standards - Calibration standards at a minimum of five concentrations should be prepared from the secondary dilution of stock standards (see Sections 5.3 and 5.4). Prepare these solutions in organic-free reagent water. One of the concentrations should be at a concentration near, but above, the method detection limit. The remaining concentrations should correspond to the expected range of concentrations found in real samples but should not exceed the working range of the GC/MS system. Each standard should contain each analyte for detection by this method (e.g. some or all of the target analytes may be included). Calibration standards must be prepared daily. 5.9 Matrix spiking standards - Matrix spiking standards should be prepared from volatile organic compounds which will be representative of the compounds being investigated. The suggested compounds are I, I-dichloroethene, trichloroethene, chlorobenzene, toluene, and benzene. The standard should be prepared in methanol, with each compound present at a concentration of 250 jig/10.0 mL. 8240A - 8 Revision 1 November 1990 5.10 Great care must be taken to maintain the integrity of all standard solutions. It is recommended that all standards in methanol be stored at -10C to -20C in screw cap amber bottles with Teflon liners. 5.11 Methanol, CH,OH. Pesticide quality or equivalent. Store apart from other solvents. 5.12 Reagent Tetraglyme - Reagent tetraglyme is defined as tetraglyme in which interference is not observed at the method detection limit of compounds of interest. 5.12.1 Tetraglyme (tetraethylene glycol dimethyl ether, Aldrich #17, 240-5 or equivalent), C8H,gOj. Purify by treatment at reduced pressure in a rotary evaporator. The tfexraglyme should have a peroxide content of less than S ppm as indicated by EM quant Test Strips (available from Scientific Products Co., Catalog No. PI126-8 or equivalent). CAUTION: Glycol ethers are suspected carcinogens. All solvent handling should be done.in a hood while using proper protective equipment to minimize exposure to liquid and vapor. Peroxides may be removed by passing the tetraglyme through a column of activated alumina. The tetraglyme is placed in a round bottom flask equipped with a standard taper joint, and the flask is affixed to.a rotary evaporator. The flask is immersed in a water bath at 90-100C and a vacuum is maintained at < 10 mm Hg for at least two hours using a two stage mechanical pump. The vacuum system is equipped with an all glass trap, which is maintained in a dry ice/methanol bath. Cool the tetraglyme to ambient temperature and add 0.1 mg/ral of 2,6-di-tert-butyl-4-methyl-phenol to prevent peroxide formation. Store the tetraglyme in a tightly sealed screw cap bottle in an area that is not contaminated by solvent vapors. 5.12.2 In order to demonstrate that all interfering volatiles have been removed from the tetraglyme, an organic-free reagent water/tetraglyme blank must be analyzed. 5.13 Polyethylene glycol, H(0CHjCH,)n0H. Free of interferences at the detection limit of the analytes. 6.0 SAMPLE COLLECTION, PRESERVATION, AND HANDLING 6.1 See the introductory material to this chapter, Organic Analytes, Section 4.1. 7.0 PROCEDURE 7.1 Oirect Injection - In very limited applications (e.g. aqueous process wastes), direct Injection of the sample into the GC/MS system with a 10 jiL syringe may be appropriate. One such application is for verification of the alcohol content of an aqueous sample prior to determining if the sample is ignitable (Methods 1010 or 1020). In this case, it is suggested that direct S240A - 9 Revision 1 November 1990 BFG39998 injection be used. The detection limit is very high (approximately 10,000 ^g/L); therefore, it is only permitted when concentrations in excess of 10,000 Mg/l are expected or for water soluble compounds that do not purge. The system must be calibrated by direct injection (bypassing the purge-and-trap device). 7.2 Initial calibration for purge-and-trap procedure 7.2.1 Recommended GC/MS operating conditions Electron energy: Mass range: Scan time: Initial column temperature: Initial column holding time: Column temperature program: Final column temperature: Final column holding time: Injector temperature: Source temperature: Transfer line temperature: Carrier gas: 70 volts (nominal). 35-260 amu. To give 5 scans/peak, but not to exceed 7 sec/scan. 45C. 3 minutes. 8C/minute. 220C. 15 minutes. 200-225C. According to manufacturer's specifications. 250-300C. Hydrogen at 50 cm/sec or helium at 30 cm/sec. 7.2.2 Each GC/MS system must be hardware tuned to meet the criteria in Table 3 for a 50 ng injection or purging of 4-bromofluorobenzene (2 /it injection of the BFB standard). Analyses must not begin until these criteria are met. 7.2.3 Assemble a purge-and-trap device that meets the specification in Section 4.11. Condition the trap overnight at 180C in the purge mode with an inert gas flow of at least 20 ml/min. Prior to use, condition the trap daily for 10 min while backflushing at 180C with the column at 220C. ( 7.2.4 Connect the purge-and-trap device to a gas chromatograph. 7.2.5 Prepare the final solutions containing the required concentrations of calibration standards, including surrogate standards, directly in the purging device (use freshly prepared stock solutions when preparing the calibration standards for the initial calibration.) Add 5.0 ml of organic-free reagent water to the purging device. The organicfree reagent water is added to the purging device using a 5 mL glass syringe fitted with a 15 cm, 20 gauge needle. The needle is inserted through the sample inlet shown in Figure 1. The internal diameter of the 14 gauge needle that forms the sample inlet will permit insertion of the 20 gauge needle. Next, using a 10 pL or 25 pi microsyringe equipped with a long needle (Section 4.1), take a volume of the secondary dilution solution containing appropriate concentrations of the calibration standards (Section 5.6). Add the aliquot of calibration solution directly to the organic-free reagent water in the purging device by inserting the needle through the sample inlet. When discharging the contents of the microsyringe, be sure that the end of the syringe needle is well beneath the surface of the organic-free reagent water. Similarly, add 10 pL of gp O 8240A - 10 BFG39999 Revision 1 November 1990 the Internal standard solution (Section 5.4). Close the 2 way syringe valve at the sample Inlet. 7.2.6 Carry out the purge-and-trap analysis procedure as described In Section 7.4.1. 7.2.7 Tabulate the area response of the characteristic Ions (see Table 1) against concentration for each compound and each Internal standard. Calculate response factors (RF) for each compound relative to one of the Internal standards. The Internal standard selected for the calculation of the RF for a compound should be the Internal standard that has a retention time closest to the compound being measured (Section 7.5.2). The RF Is calculated as follows: RF - (A.CJ/W.C.) where: A, - Area of the characteristic Ion for the compound being measured. A,, Area of the characteristic ion for the specific Internal standard. C,, - Concentration of the specific internal standard. C, - Concentration of the compound being measured. 7.2.8 The average RF must be calculated for each compound. A system performance check should be made before this calibration curve is used. Five compounds (the System Performance Check Compounds, or SPCCs) are checked for a minimum average response factor. These compounds are chloromethane, 1,1-dlchloroethane, bromoform, 1,1,2,2-tetrachloroethane, and chlorobenzene. The minimum acceptable average RF for these compounds should be 0.300 (0.250 for bromoform). These compounds typically have RFs of 0.4-0.6 and are used to check compound instability and to check for degradation caused by contaminated lines or active sites in the system. Examples of these occurrences are: 7.2.8.1 Chloromethane - This compound is the most likely compound to be lost if the purge flow is too fast. 7.2.8.2 Bromoform This compound is one of the compounds most likely to be purged very poorly if the purge flow is too slow. Cold spots and/or active sites in the transfer lines may adversely affect response. Response of the quantitation ion (m/z 173) is directly affected by the tuning of BFB at ions m/z 174/176. Increasing the m/z 174/176 ratio may Improve bromoform response. 7.2.8.3 Tetrachloroethane and 1,1-dichloroethane - These compounds are degraded by contaminated transfer lines in purge-andtrap systems and/or active sites in trapping materials. 7.2.9 Using the RFs from the Initial calibration, calculate the percent relative standard deviation (XRSO) for Calibration Check Compounds (CCCs). 8240A - 11 BFG40000 Revision 1 November 1990 %RSD SD -x 100 x where: RSD - relative standard deviation, x * mean of 5 initial RFs for a compound. SD * standard deviation of average RFs for a compound. SD - N (x, - ?)J x ----------------J i*l N - 1 The %R$D for each individual CCC should be less than 30 percent. This criterion must be met in order for the individual calibration to be valid. The CCCs are: 1.1-Dichloroethene, Chloroform, 1.2-Dichloropropane, Toluene, Ethylbenzene, and Vinyl chloride. 7.3 Daily GC/MS calibration 7.3.1 Prior to the analysis of samples, inject or purge 50 ng of the 4-bromofluorobenzene standard. The resultant mass spectra for the BFB must meet all of the criteria given in Table 3 before sample analysis begins. These criteria must be demonstrated each 12 hour shift. 7.3.2 The initial calibration curve (Section 7.2) for each compound of interest must be checked and verified once every 12 hours of analysis time. This is accomplished by analyzing a calibration standard that is at a concentration near the midpoint concentration for the working range of the GC/MS by checking the SPCC (Section 7.3.3) and CCC (Section 7.3.4). 7.3.3 System Performance Check Compounds (SPCCs) - A system performance check must be made each 12 hours. If the SPCC criteria are met, a comparison of response factors is made for all compounds. This is the same check that is applied during the initial calibration. If the minimum response factors are not met, the system must be evaluated, and corrective action must be taken before sample analysis begins. The minimum response factor for volatile SPCCs is 0.300 (0.250 for Bromoform). Some possible problems are standard mixture degradation, injection port inlet contamination, contamination at the front end of the analytical column, and active sites in the column or chromatographic system. 7.3.4 Calibration Check Compounds (CCCs): After the system performance check is met, CCCs listed in Section 7.2.9 are used to check the validity of the initial calibration. Calculate the percent difference using: 8240A - 12 BFG40001 Revision 1 November 1990 I C/T $0 C4 RF, - RFe % Difference - ----------- RF, x 100 where: RF, - average response factor from initial calibration. RFe * response factor from current verification check standard. If the percent difference for any compound is greater than 20, the laboratory should consider this a warning limit. If the percent difference for each CCC is less than 25%, the initial calibration is assumed to be valid. If the criterion is not met (> 25% difference), for any one CCC, corrective action MUST be taken. Problems similar to those listed under SPCCs could affect this criterion. If no source of the problem can be determined after corrective action hasbeen taken, a new five point calibration MUST be generated. This criterion MUST be met before quantitative sample analysis begins. 7.3.5 The internal standard responses and retention times in the check calibration standard must be evaluated immediately after or during data acquisition. If the retention time for any internal standard changes by more than 30 seconds from the last check calibration (12 hours), the chromatographic system must be inspected for malfunctions and corrections must be made, as required. If theEICP area for any of the internal standards changes by a factor of two (- 50% to + 100%) from the last daily calibration standard check, the mass spectrometer must be Inspected for malfunctions and corrections must be made, as appropriate. When corrections are made, reanalysis of samples analyzed while the system was malfunctioning are necessary. 7.4 GC/MS analysis 7.4.1 Water samples 7.4.1.1 Screening of the sample prior to purge-and-trap analysis will provide guidance on whether sample dilution is necessary and will prevent contamination of the purge-and-trap system. Two screening techniques that can be used are: the headspace sampler (Method 3810) using a gas chromatograph (GC) equipped with a photo ionization detector (PID) in series with an electrolytic conductivity detector (HECD); and extraction of the sample with hexadecane and analysis of the extract on a GC with a FIO and/or an ECO (Method 3820). 7.4.1.2 All samples and standard solutions must be allowed to warm to ambient temperature before analysis. 7.4.1.3 Set up the GC/MS system as outlined in Section 7.2.1. 7.4.1.4 BFB tuning criteria and daily GC/MS calibration criteria must be met (Section 7.3) before analyzing samples. '8240A - 13 Revision 1 November 1990 BFG40002 7.4.1.5 Adjust the purge gas (helium) flow rate to 2540 mL/min on the purge-and-trap device. Optimize the flow rate to provide the best response for chloromethane and bromoform, if these compounds are analytes. Excessive flow rate reduces chloromethane response, whereas insufficient flow reduces bromoform response (see Section 7.2.8). 7.4.1.6 Remove the plunger from a 5 ml syringe and attach a closed syringe valve. Open the sample or standard bottle, which has been allowed to come to ambient temperature, and carefully pour the sample into the syringe barrel to just short of overflowing. Replace the syringe plunger and compress the sample. Open the syringe valve and vent any residual air while adjusting the sample volume to 5.0 mL. This process of taking an aliquot destroys the validity of the liquid sample for future analysis; therefore, if there is only one VOA vial, the analyst should fill a second syringe at this time to protect against possible loss of sample integrity. This second sample is maintained only until such time when the analyst has determined that the first sample has been analyzed properly. Filling one 20 ml syringe would allow the use of only one syringe. If a second analysis is needed from a syringe, it must be analyzed within 24 hours. Care must be taken to prevent air from leaking into the syringe. 7.4.1.7 The following procedure is appropriate for diluting purgeable samples. All steps must be performed without delays until the diluted sample is in a gas tight syringe. 7.4.1.7.1 Dilutions may be made in volumetric flasks (10 to 100 ml). Select the volumetric flask that will allow for the necessary dilution. Intermediate dilutions may be necessary for extremely large dilutions. 7.4.1.7.2 Calculate the approximate volume of organicfree reagent water to be added to. the volumetric flask selected and add slightly less than this quantity of organic-free reagent water to the flask. 7.4.1.7.3 Inject the proper aliquot of samples from the syringe prepared in Section 7.4.1.6 into the flask. Aliquots of less than 1 ml are not recommended. Oilute the sample to the mark with organic-free reagent water. Cap the flask, invert, and shake three times. Repeat above procedure for additional dilutions. 7.4.1.7.4 Fill a 5 mL syringe with the diluted sample as in Section 7.4.1.6. 7.4.1.8 Add 10.0 yL of surrogate spiking solution (Section 5.3) and 10 ul of internal standard spiking solution (Section 5.4) through the valve bore of the syringe; then close the valve. The surrogate and internal standards may be mixed and added as a single spiking solution. The addition of 10 yl of the surrogate spiking 8240A - 14 BFG40003 Revision 1 November 1990 solution to 5 ml of sample is equivalent to a concentration of 50 ng/i of each surrogate standard. 7.4.1.9 Attach the syringe-syringe valve assembly to the syringe valve on the purging device. Open the syringe valves and inject the sample into the purging chamber. 7.4.1.10 Close both valves and purge the sample for 11.0 + 0.1 minutes at ambient temperature. 7.4.1.11 At the conclusion of the purge time, attach the trap to the chromatograph, adjust the device to the desorb mode, and begin the gas chromatographic temperature program and GC/MS data acquisition. Concurrently, introduce the trapped materials to the gas chromatographic column by rapidly heating the trap to 180C while backflushing the trap with inert gas between 20 and 60 ml/min for 4 minutes. If this rapid heating requirement cannot be met, the gas chromatographic column must be used as a secondary trap by cooling it to 30C (or subambient, if problems persist) instead of the recommended initial program temperature of 45C. 7.4.1.12 While the trap is being desorbed into the gas chromatograph, empty the purging chamber. Wash the chamber with a minimum of two 5 ml flushes of organic-free reagent water (or methanol followed by organic-free reagent water) to avoid carryover of pollutant compounds into subsequent analyses. 7.4.1.13 After desorbing the sample for 4 minutes, recondition the trap by returning the purge-and-trap device to the purge mode. Wait 15 seconds; then close the syringe valve on the purging device to begin gas flow through the trap. The trap temperature should be maintained at 180C. Trap temperatures up to 220C may be employed; however, the higher temperature will shorten the useful life of the trap. After approximately 7 minutes, turn off the trap heater and open the syringe valve to stop the gas flow through the trap. When cool, the trap is ready for the next sample. 7.4.1.14 If the initial analysis of a sample or a dilution of the sample has a concentration of analytes that exceeds the initial calibration range, the sample must be reanalyzed at a higher dilution. Secondary ion quantitation is allowed only when there are sample interferences with the primary ion. When a sample is analyzed that has saturated ions from a compound, this analysis must be followed by a blank organic-free reagent water analysis. If the blank analysis is not free of interferences, the system must be decontaminated. Sample analysis may not resume until a blank can be analyzed that is free of interferences. 7.4.1.15 For matrix spike analysis, add 10 fiL of the matrix spike solution (Section 5.7) to the 5 mL of sample to be purged. Disregarding any dilutions, this is equivalent to a concentration of 50 ng/L of each matrix spike standard. 8240A - 15 BFG40004 Revision 1 November 1990 7.4.1.16 All dilutions should keep the response of the major constituents (previously saturated peaks) in the upper half of the linear range of the curve. Proceed to Sections 7.5.1 and 7.5.2 for qualitative and quantitative analysis. 7.4.2 Water miscible liquids 7.4.2.1 Water miscible liquids are analyzed as water samples after first diluting them at least 50 fold with organic-free reagent water. 7.4.2.2 Initial and serial dilutions can be prepared by pipetting 2 ml of the sample to a 100 ml volumetric flask and diluting to volume with organic-free reagent water. Transfer immediately to a 5 ml gas tight syringe. 7.4.2.3 Alternatively, prepare dilutions directly in a 5 ml syringe filled with organic-free reagent water by adding at least 20 pL, but not more than 100 pi of liquid sample. The sample is ready for addition of internal and surrogate standards. 7.4.3 Sediment/soil and waste samples - It is highly recommended that all samples of this type be screened prior to the purge-and-trap GC/MS analysis. The headspace method (Method 3810) or the hexadecane extraction and screening method (Method 3820) may be used for this purpose. These samples may contain percent quantities of purgeable organics that will contaminate the purge-and-trap system, and require extensive cleanup and instrument downtime. Use the screening data to determine whether to use the low-concentration method (0.005-1 mg/Kg) or the high-concentration method (> 1 mg/Kg). 7.4.3.1 Low-concentration method - This is designed for samples containing individual purgeable compounds of < 1 mg/Kg. It is limited to sediment/soil samples and waste that is of a similar consistency (granular and porous). The low-concentration method is based on purging a heated sediment/soll sample mixed with organicfree reagent water containing the surrogate and internal standards. Analyze all reagent blanks and standards under the same conditions as the samples. See Figure 5 for an illustration of a low soils impinger. 7.4.3.1.1 Use a 5 g sample if the expected concentration is < 0.1 mg/Kg or a 1 g sample for expected concentrations between 0.1 and 1 mg/Kg. 7.4.3.1.2 The GC/MS system should be set up as in Sections 7.4.1.2-7.4.1.4. This should be done prior to the preparation of the sample to avoid loss of volatiles from standards and samples. A heated purge calibration curve must be prepared and used for the quantitation of all samples analyzed with the low-concentration method. Follow the initial and daily calibration instructions, except for the addition of a 40C purge temperature. 8240A - 16 BFG40005 Revision 1 November 1990 7.4.3.1.3 Remove the plunger from a 5 mL Luerlock type syringe equipped with a syringe valve and fill until overflowing with water. Replace the plunger and compress the water to vent trapped air. Adjust the volume to 5.0 ml. Add 10 ui each of surrogate spiking solution (Section 5.3) and internal standard solution (Section 5.4) to the syringe through the valve. (Surrogate spiking solution and internal standard solution may be mixed together.) The addition of 10 mL of the surrogate spiking solution to 5 g of sediment/soil is equivalent to 50 ng/Kg of each surrogate standard. 7.4.3.1.4 The sample (for volatile organics) consists of the entire contents of the sample container. Do not discard any supernatant liquids. Mix the contents of the sample container with a narrow metal spatula. Weigh the amount determined in Section 7.4.3.1.1 into a tared purge device. Note and record the actual weight to the nearest 0.1 g. 7.4.3.1.5 Determine the percent dry weight of the soil/sediment sample. This includes waste samples that are amenable to percent dry weight determination. Other wastes should be reported on a wet-weight basis. 7.5.3.1.5.1 Immediately after weighing the sample for extraction, weigh 5-10 g of the sample into a tared crucible. Determine the % dry weight of the sample by drying overnight at 105C. Allow to cool in a desiccator before re-weighing. Concentrations of individual analytes are reported relative to the dry weight of sample. WARNING: The drying oven should be contained in a hood or vented. Significant laboratory contamination may result from a heavily contaminated hazardous waste sample. % dry weight - o of dry sample x 100 g of sample 7.4.3.1.6 Add the spiked water to the purge device, which contains the weighed amount of sample, and connect the device to the purge-and-trap system. NOTE: Prior to the attachment of the purge device, the procedures in Sections 7.4.3.1.4 and 7.4.3.1.6 must be performed rapidly and without interruption to avoid loss of volatile organics. These steps must be performed in a laboratory free of solvent fumes. 7.4.3.1.7 Heat the sample to 40C 1C and purge the sample for 11.0 0.1 minute. 7.4.3.1.8 Proceed with the analysis as outlined in Sections 7.4.1.11-7.4.1.16. Use 5 ml of the same organic-free reagent water as in the reagent blank. If saturated peaks 8240A - 17 BFG40006 Revision 1 November 1990 occurred or would occur If a 1 g sample were analyzed, the high-concentration method must be followed. 7.4.3.1.9 For low-concentration sediment/soils add 10 mL of the matrix spike solution (Section 5.7) to the 5 ml of organic-free reagent water (Section 7.4.3.1.3). The concentration for a 5 g sample would be equivalent to 50 ug/Kg of each matrix spike standard. 7.4.3.2 High-concentration method - The method Is based on extracting the sedlment/soll with methanol. A waste sample Is either extracted or diluted, depending on its solubility In methanol. Wastes (l.e. petroleum and coke wastes) that are Insoluble in methanol are diluted with reagent tetraglyme or possibly polyethylene glycol (PEG). An aliquot of the extract Is added to organic-free reagent water containing internal standards. This is purged at ambient temperature. All samples with an expected concentration of > 1.0 mg/Kg should be analyzed by this method. 7.4.3.2.1 The sample (for volatile organics) consists of the entire contents of the sample container. Do not discard any supernatant liquids. Mix the contents of the sample container with a narrow metal spatula. For sediment/soil and solid wastes that are Insoluble In methanol, weigh 4 g (wet weight) of sample into a tared 20 ml vial. Use a top loading balance. Note and record the actual weight to 0.1 gram and determine the percent dry weight of the sample using the procedure in Section 7.4.3.1.5. For waste that Is soluble in methanol, tetraglyme, or PEG, weigh 1 g (wet weight) into a tared scintillation vial or culture tube or a 10 mL volumetric flask. (If a vial or tube is used, it must be calibrated prior to use. Pipet 10.0 mL of solvent into the vial and mark the bottom of the meniscus. Discard this solvent.) 7.4.3.2.2 Quickly add 9_0 ml of appropriate solvent; then add 1.0 mL of the surrogate spiking solution to the vial. Cap and shake for 2 minutes. NOTE: Sections 7.4.3.2.1 and 7.4.3.2.2 must be performed rapidly and without interruption to avoid loss of volatile organics. These steps must be performed In a laboratory free from solvent fumes. 7.4.3.2.3 Pipet approximately 1 ml of the extract to a GC vial for storage, using a disposable pipet. The remainder may be disposed of. Transfer approximately 1 ml of appropriate solvent to a separate GC vial for use as the method blank for each set of samples. These extracts may be stored at 4C in the dark, prior to analysis. The addition of a 100 ni aliquot (sj of each of these extracts in Section 7.4.3.2.6 will give a CD concentration equivalent to 6,200 m9/^9 of each surrogate C/1 standard. t- 8240A - 18 BFG40007 Revision 1 November 1990 7.4.3.2.4 The GC/MS system should be set up as in Sections 7.4.1.2-7.4.1.4. This should be done prior to the addition of the solvent extract to organic-free reagent water. 7.4.3.2.5 Table 4 can be used to determine the volume of solvent extract to add to the 5 ml of organic-free reagent water for analysis. If a screening procedure was followed (Method 3810 or 3820), use the estimated concentration to determine the appropriate volume. Otherwise, estimate the concentration range of the sample from the low-concentration analysis to determine the appropriate volume. If the sample was submitted as a high-concentration sample, start with 100 pi. All dilutions must keep the response of the major constituents (previously saturated peaks) in the upper half of the linear range of the curve. 7.4.3.2.6 Remove the plunger from a 5.0 ml Luerlock type syringe equipped with a syringe valve and fill until overflowing with water. Replace the plunger and compress the water to vent trapped air. Adjust the volume to 4.9 ml. Pull the plunger back to 5.0 ml to allow volume for the addition of the sample extract and of standards. Add 10 pi of internal standard solution. Also add the volume of solvent extract determined in Section 7.4.3.2.5 and a volume of extraction or dissolution solvent to total 100 pi (excluding methanol in standards). 7.4.3.2.7 Attach the syringe-syringe valve assembly to the syringe valve on the purging device. Open the syringe valve and inject the organic-free reagent water/methanol sample into the purging chamber. 7.4.3.2.8 Proceed with the analysis as outlined in Section 7.4.1.11-7.4.1.16. Analyze all reagent blanks on the same Instrument as that use for the samples. The standards and blanks should also contain 100 pi of solvent to simulate the sample conditions. 7.4.3.2.9 For a matrix spike in the high-concentration sediment/soil samples, add 8.0 ml of methanol, 1.0 mL of surrogate spike solution (Section 5.3), and 1.0 ml of matrix spike solution (Section 5.7) as in Section 7.4.3.2.2. This results in a 6,200 pg/Kg concentration of each matrix spike standard when added to a 4 g sample. Add a 100 pi aliquot of this extract to 5 ml of organic-free reagent water for purging (as per Section 7.4.3.2.6). 7.5 Data interpretation 7.5.1 Qualitative analysis 7.5.1.1 An analyte (eg. those listed in Table 1) is identified by comparison of the sample mass spectrum with the mass 8240A - 19 Revision 1 November 1990 BFG40008 spectrum of a standard of the suspected compound (standard reference spectrum). Mass spectra for standard reference should be obtained on the user's GC/MS within the same 12 hours as the sample analysis. These standard reference spectra may be obtained through analysis of the calibration standards. Two criteria must be satisfied to verify identification: (1) elution of sample component at the same GC relative retention time (RRT) as those of the standard component; and (2) correspondence of the sample component and the standard component mass spectrum. 7.5.1.1.1 The sample component RRT must compare within + 0.06 RRT units of the RRT of the standard component. For reference, the standard must be run within the same 12 hours as the sample. If coelution of interfering components prohibits accurate assignment of the sample component RRT from the total ion chromatogram, the RRT should be assigned by using extracted ion current profiles for ions unique to the component of interest. 7.5.1.1.2 (1) All ions present in the standard mass spectra at a relative intensity greater than 10% (most abundant ion in the spectrum equals 100% must be present in the sample spectrum). (2) The relative intensities of ions specified in (1) must agree within plus or minus 20% between the standard and sample spectra. (Example: For an ion with an abundance of 50% in the standard spectra, the corresponding sample abundance must be between 30 and 70 percent. 7.5.1.2 For samples containing components not associated with the calibration standards, a library search may be made for the purpose of tentative identification. The necessity to perform this type of identification will be determined by the type of analyses being conducted. Guidel ines for making tentative identification are: (1) Relative intensities of major ions in the reference spectrum (ions > 10% of the most abundant ion) should be present in the sample spectrum. (2) The relative intensities of the major ions should agree within + 20%. (Example: For an ion with an abundance of 50% in the standard spectrum, the corresponding sample ion abundance must be between 30 and 70%). (3) Molecular ions present in the reference spectrum should be present in the sample spectrum. (4) Ions present in the sample spectrum but not in the reference spectrum should be reviewed for possible background contamination or presence of coeluting compounds. (5) Ions present in the reference spectrum but not in the sample spectrum should be reviewed for possible subtraction from the sample spectrum because of background contamination or coeluting Vf?03&ZS2 8240A - 20 Revision 1 November 1990 BFG40009 peaks. Data system library reduction programs can sometimes create these discrepancies. Computer generated library search routines should not use normal ization routines that would misrepresent the library or unknown spectra when compared to each other. Only after visual comparison of sample with the nearest library searches will the mass spectral interpretation specialist assign a tentative identification. 7.5.2 Quantitative analysis 7.5.2.1 When a compound has been identified, the quantitation of that compound will be based on the integrated abundance from the EICP of the primary characteristic ion. Quantitation will take place using the internal standard technique. The internal standard used shall be the one nearest the retention time of that of a given analyte (e.g. see Table 5). 7.5.2.2 Calculate the concentration of each identified analyte in the sample as follows: Water and Water-Miscible Waste: concentration [ng/l) (A. )(1.) -------------------- ^-- (AJ(RF)(V0) where: A, I, A,,RF - V,, Area of characteristic ion for compound being measured. Amount of internal standard injected (ng). Area of characteristic ion for the internal standard. Response factor for compound being measured (Section 7.3.6). Volume of water purged,-(ml), taking into consideration any dilutions made. Sediment/Soil, Sludge, and Waste: High-concentration: concentration (^g/Kg) (A. )d,) (V,) (AJ(RF)(Vt)(WJ low-concentration: concentration (^g/Kg) (A. )(U (AJ(RF)(W.) 8240A - 21 BFG40010 Revision 1 November 1990 where: K> I,. A*, Rf7 Same as in water and water-miscible waste above. V, - Volume of total extract (jjL) (use 10,000 fil or a factor of this when dilutions are made). V, - Volume of extract added (nL) for purging. W, Weight of sample extracted or purged (g). The wet weight or dry weight may be used, depending upon the specific applications of the data. 7.5.2.3' Sediment/soil samples are generally reported on a dry weight basis, while sludges and wastes are reported on a wet weight basis. The percent dry weight of the sample (as calculated in Section 7.4.3.1.5) should be reported along with the data in either instance. 7.5.2.4 Where applicable, an estimate of concentration for noncalibrated components in the sample should be made. The formulae given above should be used with the following modifications: The areas A, and A,, should be from the total ion chromatograms, and the RF for the compound should be assumed to be 1. The concentration obtained should be reported indicating (1) that the value is an estimate and (2) which internal standard was used to determine concentration. Use the nearest internal standard free of interferences. 8.0 QUALITY CONTROL 8.1 Refer to Chapter One and Method 8000 for specific quality control procedures. 8.2 Required instrument QC is found in the following sections: 8.2.1 The GC/MS system must be tuned to meet the BFB specifications in Section 7.2.2. 8.2.2 There must be an initial calibration of the GC/MS system as specified in Section 7.2. 8.2.3 The GC/MS system must meet the SPCC criteria specified in Section 7.3.3 and the CCC criteria in Section 7.3.4, each 12 hours. 8.3 To establish the ability to generate acceptable accuracy and precision, the analyst must perform the following operations. 8.3.1 A quality control (QC) reference sample concentrate is required containing each analyte at a concentration of 10 mg/L in methanol. The QC reference sample concentrate may be prepared from pure standard materials or purchased as certified solutions. If prepared by the laboratory, the QC reference sample concentrate must be made using stock standards prepared independently from those used for calibration. l!"u s te 8240A - 22 BFG40011 Revision 1 November 1990 8.3.2 Prepare a QC reference sample to contain 20 4g/L of each analyte by adding 200 /iL of QC reference sample concentrate to 100 ml of organic-free reagent water. 8.3.3 Four 5 ml aliquots of the well mixed QC reference sample are analyzed according to the method beginning in Section 7.4.1. 8.3.4 Calculate the average recovery (x) in ng/i, and the standard deviation of the recovery (s) in /ug/l, for each analyte using the four results. 8.3.5 For each analyte compare s and x with the corresponding acceptance criteria_for precision and accuracy, respectively, found in Table 6. If s and x for all analytes meet the acceptance criteria, the system performance is acceptable and analysis of actual samples can_begin. If any individual s exceeds the precision limit or any individual x falls outside the range for accuracy, then the system performance is unacceptable for that analyte. NOTE; The large number of analytes in Table 6 present a substantial probability that one or more will fail at least one of the acceptance criteria when all analytes of a given method are determined. 8.3.6 When one or more of the analytes tested fail at least one of the acceptance criteria, the analyst must proceed according to Section 8.3.6.1 or 8.3.6.2. 8.3.6.1 Locate and correct the source of the problem and repeat the test for all analytes beginning with Section 8.3.2. 8.3.6.2 Beginning with Section 8.3.2, repeat the test only for those analytes that failed to meet criteria. Repeated failure, however, will confirm a general problem with the measurement system. If this occurs, locate and correct the source of the problem and repeat the test for all compounds of-interest beginning with Section 8.3.2. 8.4 For aqueous and soil matrices, laboratory established surrogate control limits should be compared with the control limits listed in Table 8. The limits given in Table 8 are multi laboratory performance based limits for soil and aqueous samples, and therefore, the single laboratory limits must fall within those given in Table 8 for these matrices. 8.4.1 If recovery is not within limits, the following procedures are required. 8.4.1.1 Check to be sure that there are no errors in the calculations, surrogate solutions or internal standards. If errors are found, recalculate the data accordingly. 8.4.1.2 Check Instrument performance. If an instrument performance problem is identified, correct the problem and re-analyze the extract. 824QA - 23 Revision 1 November 1990 BFG40012 8.4.1.3 If no problem is found, re-extract and re-analyze the ssmple. 8.4.1.4 If, upon re-analysis, the recovery is again not within limits, flag the data as "estimated concentration". 8.4.2 At a minimum, each laboratory should update surrogate recovery limits on a matrix-by-matrix basis, annually. 9.0 METHOD PERFORMANCE 9.1 The method detection limit (MDL) is defined as the minimum concentration of a substance that can be measured and reported with 99% confidence that the value is above zero. The MDL concentrations listed in Table 1 were obtained using organic-free reagent water. Similar results were achieved using representative wastewaters. The MDL actually achieved in a given analysis will vary depending on instrument sensitivity and matrix effects. 9.2 This method was tested by 15 laboratories using organic-free reagent water, drinking water, surface water, and industrial wastewaters spiked at six concentrations over the range 5-600 yg/L. Single operator precision, overall precision, and method accuracy were found to be directly related to the concentration of the analyte and essentially independent of the sample matrix. Linear equations to describe these relationships are presented in Table 7. 10.0 REFERENCES 1. U.S. EPA 40 CFR Part 136, "Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act, Method 624," October 26, 1984. 2. U.S. EPA Contract Laboratory Program, Statement of Work for Organic Analysis, July 1985, Revision. 3. Sellar, T.A., and J.J. lichtenberg, J. Amer. Water Works Assoc., 66(12), 739-744, 1974. 4. Bellar, T.A., and J.J. Lichtenberg, "Semi-Automated Headspace Analysis of Drinking Waters and Industrial Waters for Purgeable Volatile Organic Compounds," in Van Hall, ed., Measurement of Organic Pollutants in Water and Wastewater, ASTM STP 686, pp. 108-129. 1979. 5. Budde, W.L. and J.W. Eichelberger, "Performance Tests for the Evaluation of Computerized Gas Chromatography/Mass Spectrometry Equipment and Laboratories," EPA-600/4-79-020. U.S. Environmental Protection Agency, Environmental Monitoring and Support Laboratory, Cincinnati, Ohio 45268, April 1980. 6. Eichelberger, J.W., L.E. Harris, and W.L. Budde, "Reference Compound to Calibrate Ion Abundance Measurement m Gas Chromatography-Mass Spectrometry Systems," Analytical Chemistry, 47, 995-1000, 1975. 8240A - 24 BFG40013 Revision 1 November 1990 7. "Method Detection Limit for Methods 624 and 625," Olynyk, P., W.L. Budde, and J.W. Eichelberger, Unpublished report, October 1980. 8. "Interlaboratory Method Study for EPA Method 624-Purgeables," Final Report for EPA Contract 68-03-3102. 9. "Method Performance Data for Method 624," Memorandum from R. Slater and T. Pressley, U.S. Environmental Protection Agency, Environmental Monitoring and Support Laboratory, Cincinnati, Ohio 45268, January 17, 1984. 10. Gebhart, O.E.; Lucas, S.V.; Naber, S.J.; Berry, A.M.; Danison, T.H.; Burkholder, H.M. "Validation of SW-846 Methods 8010, 8015, and 8020"; U.S. Environmental Protection Agency, Environmental Monitoring and Support Laboratory, Cincinnati, Old 45268, July 1987, Contract No. 68-03-1760. 11. Lucas, S.V.; Kornfeld, R.A. "6C-MS Suitability Testing of RCRA Appendix VIII and Michigan List Analytes U.S. Environmental Protection Agency, Environmental Monitoring and Support Laboratory, Cincinnati, OH 45268, February 20, 1987, Contract No. 68-03-3224. 8240A - 25 BFG40014 Revision 1 November 1990 TABLE 1. RETENTION TIMES AND CHARACTERISTIC IONS FOR VOLATILE COMPOUNDS Compound Retention Time (minutes) Primary Ion Secondary Ion(s) Ethylene oxide Chloromethane Diehlorodif1uoromethane Bromomethane Vinyl chloride Acetonitrile Chloroethane Methyl iodide Methylene chloride Carbon disulfide Trichiorof1uoromethane Propionitrile Allyl chloride 1,1-Dichloroethene Bromochloromethane (I.S.) Allyl alcohol trans-l,2-Dichloroethene 1,2-Dichloroethane Propargyl alcohol Chloroform l,2-Dichloroethane-d(surr) 2-Butanone Methacrylonitrile Di bromomethane 2-Chloroethanol b-Propiolactone Epichlorohydrin 1,1,1-Trichloroethane Carbon tetrachloride 1,4-Dioxane Isobutyl alcohol Bromodichioromethane Chloroprene 1,2:3,4-Diepoxybutane 1,2-Dichloropropane cis-l,3-Dichloropropene Bromoacetone Trichloroethene Benzene trans-1,3-Dichloropropene 1,1,2-Trichloroethane 3-Chloropropionitrile 1,2-Dibromoethane Pyridine 1.30 2.30 2.47 3.10 3.80 3.97 4.60 5.37 6.40 7.47 8.30 8.53 8.83 9.00 9.30 9.77 10.00 10.10 10.77 11.40 12.10 12.20 12.37 12.53 12.93 13.00 13.10 13.40 13.70 13.70 13.80 14.30 14.77 14.87 15.70 15.90 16.33 16.50 17.00 17.20 17.20 17.37 18.40 18.57 44 44, 43, 42 50 52, 49 85 85, 87, 101, 103 94 96, 79 62 64, 61 41 41, 40, 39 64 66, 49 142 142, 127, 141 84 49, 51, 86 76 76, 78, 44 101 103, 66 54 54, 52, 55, 40 76 76, 41, 39, 78 96 61, 98 128 49, 130, 51 57 57, 58, 39 96 61, 98 62 64, 98 55 55, 39, 38, 53 83 85, 47 65 102 72 43, 72 41 41, 67, 39, 52, 66 93 93, 174, 95, 172, 176 49 49, 44, 43, 51, 80 42 42, 43, 44 57 57, 49, 62, 51 97 99, 117 117 119, 121 88 88, 58, 43, 57 43 43, 41, 42, 74 83 85, 129 53 53, 88, 90, 51 55 55, 57, 56 63 62, 41 75 77, 39 136 43, 136, 138, 93, 95 130 95, 97, 132 78 52, 71 75 77, 39 97 83, 85, 99 54 54, 49, 89, 91 (0 107 107, 109, 93, 188 79 79, 52, 51, 50 8240A - 26 BFG40015 Revision 1 November 1990 TABLE 1. (Continued) Compound Retention Time (minutes) Primary Ion Secondary Ion(s) 2-Chloroethyl vinyl ether 2-Hydroxypropionitrile 1,4-Difluorobenzene (I.S.) Malononitrile Methyl methacrylate Bromoform 1,1,1,2-Tetrachloroethane l,3-0ichloro-2-propanol 1,1,2,2-Tetrachloroethane Tetrachloroethene 1,2,3-Trichloropropane 1,4-Dichloro-2-butene n-Propyl amine 2-Picoline Toluene Ethyl methacrylate Chlorobenzene Pentachloroethane* Ethylbenzene 1,2-Dibromo-3-chloropropane 4-Bromofluorobenzene (surr.) Benzyl chloride Styrene Acetone Acrolein Acrylonitrile Chlorobenzene-d5 (I.S.) Chlorodibromomethane 1,1-Dichloroethane Ethanol 2-Hexanone Iodomethane 4-Methyl-2-pentanone Toluene*d# (surr.) Vinyl acetate Xylene (Total) 18.60 18.97 19.60 19.60 19.77 19.80 20.33 21.83 22.10 22.20 22.20 22.73 23.00 23.20 23.50 23.53 24.60 24.83 26.40 27.23 28.30 29.50 30.83 -- -- -- -- -- -- -- ** 63 65,106 44 44,43,42,53 114 63.88 66 66,39,65,38 69 69,41,100,39 173 171,175,252 131 131,133,117,119,95 79 79,43,81,49 83 85,131,133 164 129,131,166 75 75,77,110,112,97 75 75,53,77,124,89 59 59,41,39 93 93,66,92,78 92 91,65 69 69,41,99,86,114 112 114,77 167 167,130,132,165,169 106 91 157 157,75,155,77 95 174,176 91 91,126,65,128 104 104,103,78,51,77 43 58 56 55,58 53 52,51 117 82,119 129 208,206 63 65,83 31 45,27,46 43 58,57, 100 142 127,141 43 58,57,100 98 70,100 43 86 106 91 a The base peak at m/e 117 was not used due to an interference at that mass with a nearly coeluting internal standard, chlorobenzene-d5. 8240A - 27 BFG40016 Revision 1 November 1990 TABLE 2. ESTIMATED QUANTITATION LIMITS (EQL) FOR VOLATILE ORGANICS' Volatiles Estimated Quantitation Limits8 Ground water ng/l Low Soil/Sediment ng/Kg Acetone Acetonitrile Allyl chloride Benzene Benzyl chloride Bromodichloromethane Bromoform Bromomethane 2-8utanone Carbon disulfide Carbon tetrachloride Chlorobenzene Chiorodibromomethane Chloroethane 2-Chloroethyl vinyl ether Chloroform Chloromethane Chloroprene 1.2-Dibromo-3-chloropropane 1.2-Dibromoethane Dibromomethane 1,4-0ichloro-2-butene Diehlorodifluoromethane 1.1-Dichloroethane 1.2-Dichloroethane 1,1 Dichloroethene trans-l,2-0ichloroethene 1.2-Dichloropropane cis-l,3-Dichloropropene trans-1,3-Dichloropropene Ethylbenzene Ethyl methacrylate 2-Hexanone Isobutyl alcohol Methacrylonitrile Methylene chloride Methyl iodide Methyl methacrylate 4-Methyl-2-pentanone Pentachloroethane 100 100 5 5 100 5 5 10 100 100 5 5 5 10 10 5 10 5 100 5 5 100 5 5 5 5 5 5 5 5 5 5 50 100 100 5 5 5 50 10 100 100 5 5 100 5 5 10 100 100 5 5 5 10 10 5 10 5 100 s 5 100 5 5 5 5 5 5 5 5 5 5 50 100 100 5 5 50 SO 10 ft cn i: 8240A - 28 Revision 1 November 1990 BFG40017 TABLE 2. (Continued) Volatiles Estimated Quantitation Limits6 Ground water mq/l Low Soil/Sediment (iq/Kq Propionitrile Styrene 1,1,1,2-Tetrachloroethane 1,1,2,2-Tetrachloroethane Tetrachloroethene Toluene 1,1,1-Trichloroethane 1,1,2-Trichioroethane Trichloroethene 1,2,3-Trichloropropane Vinyl acetate Vinyl chloride Xylene (Total) 100 5 5 5 5 5 5 5 5 5 50 10 5 100 5 5 5 5 5 5 5 5 5 50 10 5 a Sample EQLs are highly matrix dependent. The EQLs listed herein are provided for guidance and may not always be achievable. See the following information for further guidance on matrix dependent EQLs. b EQLs listed for soil/sediment are based on wet weight. Normally data is reported on a dry weight basis; therefore, EQLs will be higher, based on the percent dry weight of each sample. Other Matrices Factor' Water miscible liquid waste High-concentration soil and sludge Non-water miscible waste 50 125 500 eEQL - [EQL for low soil sediment (Table 2)] X (Factor). For non-aqueous samples, the factor is on a wet weight basis. 8240A - 29 BFG40018 Revision 1 November 1990 Mass 50 75 95 96 173 174 175 176 177 TABLE 3. BFB KEY ION ABUNDANCE CRITERIA Ion Abundance Criteria 15 to 40% of mass 95 30 to 60% of mass 95 base peak, 100% relative abundance 5 to 9% of mass 95 less than 2% of mass 174 greater than 50% of mass 95 5 to 9% of mass 174 greater than 95% but less than 101% of mass 174 5 to 9% of mass 176 TA8LE 4. QUANTITY OF METHANOL EXTRACT REQUIRED FOR ANALYSIS OF HIGH-CONCENTRATION SOILS/SEDIMENTS Approximate Concentration Range 500- 10,000 ng/Kg 1.000- 20,000 ng/Kg 5.000-100,000 M9/Kg 25,000-500,000 *xg/Kg Volume of Methanol Extract* 100 Hi 50 nl 10 Hi 100 mL of 1/50 dilution0 Calculate appropriate dilution factor for concentrations exceeding this table. a The volume of methanol added to 5 mL of water being purged should be kept constant. Therefore, add to the 5 mL syringe whatever volume of methanol is necessary to maintain a volume of 100 hI added to the syringe. b Oilute and aliquot of the methanol extract and then take 100 jit for analysis. fa fg 09 ^ 05 8240A - 30 BFG40019 Revision 1 November 1990 TABLE 5. VOLATILE INTERNAL STANOAROS WITH CORRESPONDING ANALYTES ASSIGNED FOR QUANTITATION Bromochl oromethane Acetone Acrolein Acrylonitrile Bromomethane Carbon disulfide Chloroethane Chloroform Chioromethane Diehlorodif1uoromethane 1.1- Diehloroethane 1.2- Dichloroethane 1.2- Dichloroethane-d4 (surrogate) 1,1-Dichloroethene trans-l,2-Dichloroethene Iodomethane Methylene chloride Trichiorofluoromethane Vinyl chloride 1.4-Difluorobenzene Benzene Bromodichioromethane Bromoform 2-Butanone Carbon tetrachloride Chlorodlbromomethane 2-Chloroethyl vinyl ether Dibromomethane l,4-Dichloro-2-butene 1,2-Dichloropropane cis-l,3-0ichloropropene trans-l,3-Dichloropropene 1.1.1-Trichloroethane 1.1.2-Trichloroethane Trichloroethene Vinyl acetate Chlorobenzene-dj 8romofluorobenzene (surrogate) Chlorobenzene Ethylbenzene Ethyl methacrylate 2-Hexanone 4-Methyl-2-pentanone Styrene 1,1,2,2-Tetrachloroethane Tetrachloroethene Toluene Toluene-d, (surrogate) 1,2,3-Trichloropropane Xylene 8240A - 31 BFG40020 Revision I November 1990 TABLE 6. CALIBRATION AND QC ACCEPTANCE CRITERIA' Parameter Benzene Bromodichloromethane Bromoform Bromomethane Carbon tetrachloride Chlorobenzene 2-Chloroethylvinyl ether Chloroform Chloromethane Dibromochloromethane 1,2-Dichlorobenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene 1,1-Dichloroethane 1,2-Dichloroethane 1,1-Dichloroethene trans-l,2-Dichloroethene 1,2-Dichloropropane cis-l,3-Dichloropropene trans-l,3-0ichloropropene Ethyl benzene Methylene chloride 1,1,2,2-Tetrachloroethane Tetrachloroethene Toluene l,1,1-Trichloroethane 1,1,2-Trichloroethane Trichloroethene Trichlorofluoromethane Vinyl chloride Range for Q (M9/L) 12.8-27.2 13.1-26.9 14.2-25.8 2.8-37.2 14.6-25.4 13.2-26.8 0-44.8 13.5-26.5 0-40.8 13.5-26.5 12.6-27.4 14.6-25.4 12.6-27.4 14.5-25.5 13.6-26.4 10.1-29.9 13.9-26.1 6.8-33.2 4.8-35.2 10.0-30.0 11.8-28.2 12.1-27.9 12.1-27.9 14.7-25.3 14.9-25.1 15.0-25.0 14.2-25.8 13.3-26.7 9.6-30.4 0.8-39.2 Limit for s lug/D Range for x (Mg/L) Range P.P, W 6.9 6.4 5.4 17.9 5.2 6.3 25.9 6.1 19.8 6.1 7.1 5.5 7.1 5.1 6.0 9.1 5.7 13.8 15.8 10.4 7.5 7.4 7.4 5.0 4.8 4.6 5.5 6.6 10.0 20.0 15.2-26.0 10.1-28.0 11.4-31.1 0-41.2 17.2-23.5 16.4-27.4 D-50.4 13.7-24.2 D-45.9 13.8-26.6 11.8-34.7 17.0-28.8 11.8-34.7 14.2-28.4 14.3-27.4 3.7-42.3 13.6-28.4 3.8-36.2 1.0-39.0 7.6-32.4 17.4-26.7 0-41.0 13.5-27.2 17.0-26.6 16.6-26.7 13.7-30.1 14.3-27.1 18.5-27.6 8.9-31.5 0-43.5 37-151 35-155 45-169 D-242 70-140 37-160 0-305 51-138 D-273 53-149 18-190 59-156 18-190 59-155 49-155 D-234 54-156 D-210 D-227 17-183 37-162 0-221 46-157 64-148 47-150 52-162 52-150 71-157 17-181 0-251 Q - Concentration measured in QC check sample, in tig/l. s Standard deviation of four recovery measurements, in ng/l. x * Average recovery for four recovery measurements, in ftg/L. p, p, - Percent recovery measured. 0 - Detected; result must be greater than zero. a Criteria from 40 CFR Part 136 for Method 624 and were calculated assuming a QC check sample concentration of 20 jig/L. These criteria are based directly upon the method performance data in Table 7. Where necessary, the limits for qq recovery have been broadened to assure applicability of the limits to C/1 concentrations below those used to develop Table 7. 3 & S240A - 32 Revision 1 November 1990 BFG40021 TABLE 7. METHOO ACCURACY AND PRECISION AS FUNCTIONS OF CONCENTRATION' Parameter Accuracy, as recovery, x' (M9/D Single analyst Overall precision, s/ precision, (Mg/L) S' (M9/L) Benzene Bromodichloromethane Bromoform Bromomethane Carbon tetrachloride Chlorobenzene Chloroethane 2'Chloroethylvinyl ether* Chloroform Chloromethane Dibromochloromethane 1,2-DichlorobenzeneB 1,3-Dichlorobenzene 1,4-Dichlorobenzene0 1,1-Dichloroethane 1,2-Dichloroethane 1,1-Dichloroethene trans-l,2,-Dichloroethene 1,2-D1chloropropane* cis-I,3-0ichloropropene* trans-l,3-0ichloropropene* Ethyl benzene Methylene chloride 1,1,2,2-Tetrachloroethane Tetrachloroethene Toluene 1,1,1-Trichioroethane 1,1,2-Trichioroethane Trichloroethene Trichlorofluoromethane Vinyl chloride 0.93C+2.00 1.03C-1.58 1.18C-2.35 1.00C 1.10C-1.68 0.98C+2.28 1.18C+0.81 1.00C 0.93C+0.33 1.03C-1.81 1.01C-0.03 0.94C+4.47 1.06C+1.68 0.94C+4.47 1.05C+0.36 1.02C+0.45 1.12C+0.61 1.05C+0.03 1.00C 1.00C 1.00C 0.98C+2.48 0.87C+1.88 0.93C+1.76 1.06C+0.60 0.98C+2.03 1.06C+0.73 0.95C+1.71 1.04C+2.27 0.99C+0.39 1.00C 0.26X-1.74 0.15x4-0.59 0.12x4-0.34 0.43x 0.12x4-0.25 0.16X-0.09 0.14X+2.78 0.62x 0.16x4-0.22 0.37X+2.14 0.17x-0.18 0.22X-1.45 0.14X-0.48 0.22X-1.45 0.13X-0.05 0.17X-0.32 0.17x4-1.06 0.14x4-0.09 0.33x 0.38x 0.25x 0.14X+1.00 0.15X+1.07 0.16X+0.69 0.13X-0.18 0.15X-0.71 0.12X-0.15 . O.Hx+0.02 0.13X+0.36 0.33X-1.48 0.48x 0.25x-l.33 0.20X+1.13 0.17x4-1.38 0.58X O.llx+O.37 0.26X-1.92 0.29X+1.75 0.84X 0.18X+0.16 0.58X+0.43 0.17X+0.49 0.30X-1.20 0.18X-0.82 0.30X-1.20 0.16x+0.47 0.21X-0.38 0.43x-0.22 0.19X+0.17 0.45x 0.52x 0.34x 0.26X-1.72 0.32x4-4.00 0.20x4-0. 0.16X-0.45 0.22X-1.71 0.21X-0.39 0.18x4-0.00 0.12x4-0.59 0.34x-0.39 0.65x x' - Expected recovery for one or more measurements of a sample containing a concentration of C, in pg/l. s,' - Expected single analyst standard deviation of measurements at an average concentration of x, in ng/i. S' - Expected Interlaboratory standard deviation of measurements at an average concentration found of x, in C - True value for the concentration, in *ig/l. x Average recovery found for measurements of samples containing a concentration of C, in (ig/i. a Estimates based upon the performance in a single laboratory. b Due to chromatographic resolution problems, performance statements for these isomers are based upon the sums of their concentrations. 8240A - 33 Revision I November 1990 BFG40022 TABLE 8. SURROGATE SPIKE RECOVERY LIMITS FOR WATER AND SOIL/SEDIMENT SAMPLES Surrogate Compound 4-Bromofluorobenzene lf2-Dich!oroethane-d4 Toluene-d, Low/High Water 86-115 76-114 88-110 Low/High Soil/Sediment 74-121 70-121 81-117 BFG40023 8240A - 34 go cn o Revision 1 November 1990 FIGURE 1. PURGING CHAMBER I 8240A - 35 BFG40024 Revision I November 1990 ,, FIGURE l. TRAP PACKINGS AND CONSTRUCTION TO INCLUOE DESORB CAPABILITY FOR METHOD 8240 Packing Procedure Glau Wool Silica Gal S mm t| Son Tenae 15 cm K. 3% Ov-1 Glau Wool 1 cm', S mm Trap inlet Conttruction Compratnon Pitting Nut and Ferrule* 14 Ft. 70/Foot Beiietance Wire Wrapped Solid Thermocouple/ Controller Senior Electronic Temperature Control ano Pyrometer Tubing 25 cm 0.105 In. I.O. 0.125 In. 0.0. Steinleu Steel *0 Q r. 8240A - 36 BFG40025 Revision I November 1990 FIGURE 3. SCHEMATIC OF PURGE-AND-TRAP DEVICE - PURGE MOOE FOR METHOO 8240 8240A - 37 BFG40026 Revision 1 November 1990 FIGURE 4 SCHEMATIC OF PURGE-ANO-TRAP OEVICE - OESORB MOOE FOR METHOO 8240 8240A - 38 BFG40027 / Revision 1 November 1990 FIGURE 5. LOW SOILS IMPINGER 8240A - 39 BFG40028 Revision 1 November 1990 METHOO 8240 GAS CHROMATOGRAPHY/MASS SPECTROMETRY FOR VOLATILE ORGANICS 8240A - 40 BFG40029 Revision 1 November 1990 METHOO 8240 (continued) 8240A 41 ^040030 Revision 1 November 1990 2. Aldehydes EPA - To5 BFG40031 CA {\D QD W o c? METHOD T05 Revision l.G Apri1, 1984 METHOD FOR THE DETERMINATION OF ALDEHYDES AHO KETONES IN AMBIENT AIR USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) Scope 1.1 This document describes a method for determination of individual aldehydes and ketones in ambient air. With careful attention to Veagent purity and other factors the method can detect most monofunctional aldehydes and ketones at the 1-2 ppbv level. 1.2 Specific compounds for which the method has been employed are listed in Table 1. Several studies have used the same basic method, with minor procedural differences, for analysis of ambient air (1-3). Applicable Documents , 2.1 ASTM Standards: D 1356 Definitions of Terms Related to Atmospheric Sampling and Analysis (s) 2.2 Other Documents Ambient air studies (1-3). U.S. EPA Technical Assistance Document (A) Summary of Method 3.1 Ambient air Is drawn through a midget impinger containing 10 mL of ?n 2,A-dinitrophenylhydrazine (ONPH reagent) and^lO mL of Isooctane. Aldehydes and ketones readily form stable 2,4-dinitrophenylhydrazones (ONPH derivatives). BFG40032 T05-2 3.2 The impinger solution is placed in a screw-capped vial having a teflon-lined cap and returned to the laboratory for analysis. MiSfi The ONPH derivatives are recovered by removing the isooctane iWllB.I layer, extracting the aqueous layer with 10 mL of 70/30 m hexane/methylene chloride, and combining the organic 1f layers. i 3.3 The combined organic layers are evaporated to dryness under isuu a steam of nitrogen and the residue dissolved in methanol. Stf til. 3.4 The DNPN derivatives are determined using reversed phase a HPLC with an ultraviolet (UV) adsorption detector operated at 370 nm. 4. Significance 4.1 Aldehydes and ketones are emitted into the atmosphere from .* . __ chemical operations and various combustion sources. In > addition, several of these compounds (e.g. formaldehyde and ( acetaldehyde) are produced by photochemical degradation A of other organic compounds. Many of these compounds are A ft acutely toxic and/or carcinogenic, thus requiring their determination in ambient air >n order to assess human health impacts. 4.2 Conventional methods for aldehydes and ketones have generally employed colorimetric techniques wherein only one or two compounds are detected, or the sum of numerous compounds is determined. The method described herein provides a means for specifically determining a wide variety of aldehydes and ketones at typical ambient concentrations. 5. Definitions Crt *i > Definitions used in this document and any user prepared SOPs OD c/t f should be consistent with ASTM 01356(5). All abbreviations and symbols are defined within this document at the point of use.5 i 5 j- BFG40033 i ( 6. Interferences T05-3 6.1 The only significant interferences in the method are certain isomeric aldehydes or ketones which may be unresolved by the HPLC system. Such interferences can often be overcome by altering the separation conditions (e.g. using alternate HPLC columns or mobile phase compositions). 6.2 Formaldehyde contamination of the DNPH reagent is a frequently encountered problem. The reagent must be prepared within 48 hours before use and must be stored in an uncontaminated environment before and after sampling to minimize blank problems. Acetone contamination is apparently unavoidable. Consequently, the method cannot be used to accurately measure acetone levels except in highly contaminated environments. 7. Apparatus 7.1 Isocratic HPLC system-consisting of high pressure pump, injection valve, Zorbax 00S column (25 cm x 4.6 mm ID), variable wavelength UV detector, and data system or stripchart recorded. See Figure 3. 7.2 Sampling system-capableofaccurately and precisely sampling 100-1000 mL/minute of ambient air. See Figure 1. 7.3 Stopwatch 7.4 Friction top metal can e.g. one-gallon (paint can) - to hold DNPH reagent and samples 7.5 Thermometer - to record ambient temperature. 7.6 Barometer (optional) 7.7 Analytical balance - 0.1 mg sensitivity 7.8 Reciprocating shaker 7.9 Midget impingers - jet inlet type - 25 mL volume. 7.10 Ice bath - for cooling impingers during sampling. BFG40034 T05-4 7.11 Nitrogen evaporator with heating block - for concentrating samples 7.12 Suction filtration apparatus - for filtering HPLC mobile phase. 7.13 Volumetric flasks - 100 mL and 500 ml. 7.14 Pipettes - various sizes, 1-10 mL. 7.15 Helium purge line (optional) - for degassing HPLC mobile phase. 7.16 Erlenmeyer flisk, 1-liter - for preparing HPLC mobile phase. 7.17 Graduated cylinder, 1 liter - for preparing HPLC mobile phase. 7.18 Microliter syringe, 10-25 uL - for HPLC injector. Reagents and Materials 8.1 Bottles, 10 oz. glass, with teflon-lined screw cap - for storing DNPH reagent. 8.2 Vials, io mL, with teflon-lined screw cap - for holding samples and extracts. 8.3 Disposable pipettes and bulbs. 8.4 Granular charcoal. 8.5 Methanol, hexane, methylene chloride, isooctane - distilled in glass or pesticide grade. 8.6 2,4-0initrophenylhydrazine - highest purity available (20S moisture). 8.7 Nitrogen, compressed gas cylinder -99.995 purity for sample evaporation. 8.8 Polyester filters, 0.22 um - Nuclepore or equiv. 8.9 DNPH derivatives of the components of interest - synthesized from DNPH and neat aldehydes according to reference (7). Recrystallized from ethanol before use. N I 8 BFG40035 c-v |t^iriM K > > *'< rw rr< rr*w 'n T05-5 9. Preparation of DNPH Reagent it " v - . * * 9.1 Each batch of DNPH reagent should be prepared and purified f within 48 hours of sampling, according to the procedure described in this section. i 9.2 Two hundred and fifty milligrams of solid 2,4-dinitro- phenylhydrazine and 90 ml of concentrated hydrochloric i acid are placed into a 500 ml volumetric flask and the '\ flask is filled to the mark with reagent water. The flask is then inverted several times or sonified until all of the solid material has dissolved. 9.3 Approximately 400 mL of the DNPH reagent is placed in a 16 ounce glass screw-capped bottle having a teflon-lined cap. Approximately 50 ml of a 70/30 (V/V) hexane/methylene chloride mixture is added to the bottle and the capped bottle is shaken for 15 minutes on a reciprocating shaker. The organic layer is then removed and discarded by decanting as much .as possible and using a disposable pipette to remove the remaining organic layer. 9.4 The DNPH reagent is extracted two more times as described in 9.3. The bottle is then tightly capped, sealed with teflon tape, and placed in a friction top can (paint can) containing a 1-2 Inch layer of granulated charcoal. The bottle is kept in the sealed can prior to use. 9.5 A portion of the DNPH reagent is analyzed using the procedure described in Section 11 prior to use in order to ensure that adequate background levels are maintained. 10. Sampling 10.1 The sampling apparatus is assembled and should be similar to that shown in Figure 1. EPA Method 6 uses essentially the same sampling system (8). All glassware (e.g. impingers, sampling bottles, etc.) must be thoroughly rinsed with methanol and oven dried before use. bFG40036 T05-6 10.2 Prior to sample collection the entire assembly (including empty sample impingers) is installed and the flow rate checked at a value near the desired rate. In general flow rates of 100-1000 mL/minute are useful. Flow rates greater than -vIOOO mL/minute should not be used because impinger collection efficiency may decrease. Generally calibration is accomplished using a soap bubble flow meter orv calibrated wet test meter connected to the flow exit, assuming the entire system is sealed. ASTM Method D3686 describes an appropriate calibration scheme not requiring a sealed flow system downstream of the pump. 10.3 Ideally a dry gas meter is included in the system to record total flow. If a dry gas meter is not available the operator must measure and record the sampling flow rate at the beginning and end of the sampling period to determine sample volume. If the sampling period exceeds two hours the flow rate should be measured at intermediate points during the sampling period. Ideally a rotameter should be included to allow observation of the flow rate without interruption of the sampling'.process. 10.4 To collect an air sample two clean midget impingers are loaded with 10 mL of purified ONPH reagent and 10 ml of isooctane. The impingers are connected in series to the sampling system and sample flow is started. The follow ing parameters are recorded on the data sheet (see Figure 3 for an example): date, sampling location, time, ambient temperature, barometric pressure (if available), relative humidity (if available), dry gas meter reading (if appro priate), flow rate, rotometer setting, ONPH reagent batch number, and dry gas meter and pump identification numbers. 10.5 The sampler is allowed to operate for the desired period, with periodic recording of the variables listed above. The total flow should not exceed -v.80 liters. The operator must ensure that at least 2-3 ml of isooctane remains in f the first impinger at the end of the sampling interval (i.e. for high ambient temperatures lower sampling volumes may be required). 0SS2S2 I i BFG40037 T05-7 10.6 At the end of the sampling period the parameters listed in 10.4 are recorded and the sample flow is stopped. If a dry gas meter is not used the flow rate must be checked at the end of the sampling interval. If the flow rate at the beginning and end of the sampling period differ by more than 155 the sample should be marked as suspect. 10.7 Immediately after sampling the impingers are removed from the sampling system. The contents of the first impinger are emptiedsi^to a clean 50 ml glass vial having a teflonlined screw cap. The first impinger is then rinsed with the contents of the second (backup) impinger and the rinse solution is. added to the vial. The vial is then capped, sealed with teflon tape and placed in a friction top can containing 1-2 inches of granular charcoal. The samples are stored in the can, refrigerated until analysis. 10.8 If a dry gas meter or equivalent total flow indicator is not used the average sample flow rate must be calculated according to the following equation: where + Q2 Q m Qa N Average flow rate in mL/minute. Q.j# Q2,...QN Flow rates determined at the beginning, end, and intermediate points during sampling. N Number of points averaged. 10.9 The total flow is then calculated using the following equation: BFG40038 (t2-ti)Qa Vm ------ "~ 1000 Vm Total volume sampled in liters at measured temperature and pressure T2 Stop time T| Start time (Tg-T^ given in minutes) 11. Sample Analysis T05-8 11.1 Sample Preparation 11.1.1 11.1.2 11.1.3 * . 11.1.4 The samples are returned to the laboratory in 50 ml screw-capped glass vials. To recover the DNPH derivatives the following procedure is em- pjo^ed. The vials are shaken in a horizontal position on a reciprocating shaker for 10 minutes. The vials are then removed from the shaker and the isooctane layer is removed and placed in a second clean 50 ml screw-capped glass vial using a disposable pipette. The remaining aqueous layer is extracted with 10 ml of 70/30 (V/V) hexane/methylene chloride in the same manner as described in 11.1.2. The organic layer is removed and combined with the isooctane extract. The combined organic extracts are then concentrated to dryness at 40C under a steam of pure nitrogen. When the sample just reaches dryness the vial is removed from the nitrogen stream and a measured volume (2-5 mL) of methanol is added to the vial. The vial is tightly capped and stored refrigerated until analysis. 11.2 HPLC Analysis BFG40039 11.2.1 11.2.2 The instrument is assembled and calibrated as described in Section 12. Prior to each analysis the detector ^ baseline Is checked to ensure stable operation. A 5-25 ul aliquot of the sample, dissolved in ^Q? methanol,is drawn into a clean HPLC injection syringe. The sample Injection loop is loaded and an injection <2} is made. The data system. If available. Is activated simultaneously with the injection and the point of injection is marked on the stripchart recorder. T05-9 11.2.3 11.2.4 11.2.5 11.2.6 After approximately one minute, the injection valve is returned to "load" position and the syringe and valve are flushed with methanol in preparation for the next sample analysis. After elution of the last component of interest the acquisition is terminated and the component concen trations are calculated as described in Section 13. After a stable baseline is achieved the system can be used for further sample analyses as described above, if'the concentration of a component exceeds the linear range of the instrument the sample should be diluted with methanol, or a smaller volume can be injected onto the HPLC. 12. HPLC Assembly and Calibration 12.1 The HPLC system is assembled as shown In Figure 3. The typical chromatographic performance and operating para meters are shown in Figure 4. 12.2 Mobile phase is prepared by mixing 800 mL of methanol and 200 mL of reagent water. This mixture is filtered through a 0.22 urn polyester membrane filter in an all glass and teflon suction filtration apparatus. The filtered mobile phase is degassed by purging with helium gas for 10-15 minutes 100 mL/minute) or by heating to ^60*0 for 5-10 minutes in an Erlenmeyer flask covered with a watch glass. A constant back pressure restrictor {* 50 psi) or short length (6-12 Inches) of 0.01 inch I.D. teflon tubing should be placed after the detector to further eliminate mobile phase outgassing. 12.3 The mobile phase is placed in the HPLC solvent reservoir and the pump flow is set at 1 mL/minute and allowed to pump for 20-30 minutes prior to the first analysis. The detector is switched on at least 30 minutes prior to the first analysis and the detector output is displayed on a stripchart recorder or similar output device at a sensitivity of .008 BFG40040 1T05-10 absorbance units full scale (AUFS). Once a stable baseline is achieved the system is ready for calibration. 12.4 Calibration standards are prepared in methanol from the solid DNPH derivatives. Individual stock solutions of ^ 100 mg/L are prepared by dissolving 10 mg of the solid derivative in 100 mL of methanol. These individual solutions are used to prepare calibration standards contajning all of the derivatives of interest at concentrations (of 0.1 - 10 mg/Ly which spans th^ concentration of interest for most ambient air work. All calibration runs are performed as described for sample analyses in Section 11. Before initial use the operator should inject a series of calibration standards (at least three levels) spanning the concentration range of interest. Using the UV detector, a linear response range of approximately C, 0.1 to 10 mg/L should be achieved, for 10 ul injection volumes. Linear response Is indicated where a correlation coefficient of a least 0.999 for a linear least squares fit of the-data (concentration versus area response) is obtained. * Once linear response has been documented an intermediate concentration standard near the anticipated levels for each component, but at least 10 times the detection limit, should be chosen for daily calibration. The response for the various DNPH components should be within 10% day to day. If greater variability is observed more frequent calibration may be required to ensure that valid results are obtained. The response for each component in the daily calibration standard is used to calculate a response factor according to the following equation: ce C-T i where T05-11 RFc = response factor for the component of interest in nanograms injected/response unit (usually area counts). = concentration of component in the daily calibration standard (mg/L). V| = volume of calibration standard injected (al). Rc * response for component of interest in ' ' calibration standard (area counts). 13. Calculations 13.1 The volume of air sampled is often reported uncorrected for atmospheric conditions (i.e. under ambient conditions). However, the value ten be adjusted to standard conditions (25C and 760 urn pressure) using the following equation: vm X 298 x-------------- 760 273 + Ta - where Vs total sample volume at 25*C and 760 mm Hg pressure (liters). Vm total sample volume under ambient conditions (liters). Calculated in. 10.9 or from dry gas meter reading. Pa ambient pressure (mmHg). Ta ambient temperature (*C). 13.2 The concentration of each aldehyde (as the ONPH derivative is calculated for each sample using the following equation: BFG40042 where * total quantity of derivative in the sample (u9). RFc = response factor calculated in 12.7 \ = response for component in sample extract (area counts or other response units). = final volume of sample extract (ml). Vj * volume of extract injected onto the HPLC system (UL). 13.3 The concentration of aldehyde in the original sample is calculated from the following equation: where CA ^ Vs ) X 1000 CA * concentration -of aldehyde in the original sample (ng/l). or Vs are as specified in Section 13.1. MWft and MW^ are the molecular weights (g/mole) of the aldehyde and its corresponding DNPH derivative, respectively. 13.4 The aldehyde concentrations can be converted to ppbv using the following equation: 24.4 C.(ppbv) C.(ng/l) X ------ A where CA(ng/L) is calculated using Vs. 03 C-T BfG40043 T05-13 14. Performance Criteria and Quality Assurance This section summarizes the quality assurance (QA) measures and provides guidance concerning performance criteria which should be achieved within each laboratory. 14.1 Standard Operating Procedures (SQPs). 14.1.1 14.1.2 Each user should generate SOPs describing the fpl^owing,activities as accomplished in their laboratory: 1) assembly, calibration and operation of the sampling system, 2) preparation, purification, storage and handling of DNPH reagent and samples, 3) assembly, calibration and operation of the HPIC system, and 4) all aspects of data recording and processing. SOPs should provide specific stepwise instructions and should be readily available to, and understood by, the laboratory personnel conducting the work. 14.2 HPIC System Performance 14.2.1 14.2.2 The general appearance of the HPLC chromatograph should be similar to that shown in Figure 4. The HPLC system efficiency and peak asymmetry factor should be determined in the following manner. A solution of the formaldehyde DNPH derivative cor responding to at least 20 times the detection limit should be Injected with the recorder chart sensitivity and speed set to yield a peak approximately 755 of full scale and 1 cm wide at half height. The peak asymnetry factor is determined as shown in Figure 5, and should be between 0.8 and 1.8. ... ....... .......... BFG40044 T05-14 HPLC system efficiency is calculated according to the following equation: where 14.2.4 N column efficiency, theoretical plates ' retention time of components (seconds) W]/2 8 width of component peak at half height (seconds) A column efficiency of >5,000 should be obtained. Precision of response for replicate HPLC injections should be 105 or less, day to day, for calibration standards. Precision of retention times should be * 25, on a given day. 14.3 Process Blanks Prior to use a 10 mL aliquot of each batch of DNPH reagent should be analyzed as described in Section 11. In general,formaldehyde levels equivalent to >5 ng/L in a 60 liter sample should be achieved and other aldehyde levels should be <1 ng/L. At least one field blank should be shipped and analyzed with each group of samples. The field blank is treated identically to the samples except that no air is drawn through the reagent. The same performance criteria described in 14.3.1 should be met for process blanks. BFG40045 14.4 Method Precision and Accuracy 14.4.1 Analysis of replicate samples Indicates a pre cision of 15-205 relative standard deviation can be readily achieved. Each laboratory should 14.4.2 14.4.3 collect parallel samples periodically (at least one for each batch of samples) to document their precision In conducting the method. Precision for replicate HPLC Injections should be + y>S or jbetter, day to day, for calibration standards. Method accuracy is difficult to assess because of the difficulty in generating accurate gaseous standards. Literature results indicate (1-3) recoveries of 751 or greater are achieved for a broad range of aldehydes. Each laboratory should periodically collect field samples wherein the Impinger solution is spiked with a known quantity of the compound of Interest, prepared as a dilute methanol solution. Formaldehyde cannot be spiked In this manner and therefore a solution of the DNPH derivative should be used- for spiking purposes. 14.4.4 Before Initial use of the method each laboratory should generate triplicate spiked samples at a minimum of three concentration levels, bracketing the range of interest for each compound. Triplicate nonspiked samples must also be processed. Recover ies of >70 t 205 and blank levels of <5 ng/l for formaldehyde and 1 ng/L for the other compounds (assuming a 60 liter air sample) should be achieved. BFG40046 T05-16 References (1) Grosjean, D., Fung, K., and Atkinson, R., "Measurements of Aldehydes in the Air Environment", Proc. Air Poll. Cont. Assoc., Paper 80-50.4, 1980. (2) Grosjean, D. and Fung K., "Collection Efficiencies of Cartridges and Micro-lmpingers for Sampling of Aldehydes in Air as 2,4Dinitrophenylhydrazones", Anal. Chem. 54, 1221-1224, 1982. (3) Grosjean, 0., "Formaldehyde and Other Carbonyls in Los Angeles Ambient Air", Environ. Sci. Technol. J_6, 254-262, 1982. (4) Riggin, R. M.,' "Vechnical Assistance Document for Sampling and Analysis of Toxic Organic Compounds in Ambient Air", EPA-600/4-83-027. U.S. Environmental Protection Agency, Research Triangle Park, North Carolina, 1983. (5) Annual Book of ASTM Standards, Part 11.03, "Atmospheric Analysis", American Society for Testing and Material, Philadelphia, Pennsylvania, 1983. (6) Berry, 0. A., Holdren, M. W., Lyon, T. F., Riggin, R. M., and Spicer, C. W., "Turbine Engine Exhaust Hydrocarbon Analysis-Interim Report on Task 1 and 2", Report on Contract No. F-08635-82-C-0131, Air Force Engineering and Services Center, Tyndall AFB, Florida, 1983. (7) Shiner, R.', Fuson, R., and Curtin, D., "The Systematic Identification of Organic Compounds", John Wiley and Sons, Inc., 5th ed., New York, 1964. (8) "Method 6 Determination of SO2 Emissions from Stationary Sources", Federal Register, Vol. 42.. No. 160, August 1977. BFG40047 Or *\5 so on o TOS-17 TABLE 1. ALDEHYDES AND KETONES FOR WHICH THE METHOD HAS BEEN EVALUATED Comoound Molecular Weiqht Derivative Comoound Typical Relative Retention Time(a) Formaldehyde Acetaldehyde Acrolein Propanal Acetone Crotonaldehyde IsobutyraldehydeMethyl Ethyl Ketone Benzaldehyde Pentanal o-Tolualdehyde m-Tolualdehyde p-Tolualdehyde Hexanal 210 , \ 224 236 238 238 250 252 252 286 266 300 300 300 280 30 44 56 58 58 70 72 72 106 86 120 120 120 100 1.0 1.3 1.6 1.7 1.9(b) 2.3 2.4 2.8 3.2 3.7 4.8 5.1 5.3 5.7 (a) Using HPLC conditions shown in Figure 4. Formaldehyde "1.0 (b) Acetone background levels In the reagent prevent Its determination in most cases. BFG40048 1 ? T05- 18 i 1 r:rn I I .1 il 'i Z * 1I oz i a. Z< i U< i K3a 4 I t es: i c/r a? ji il Iii > o ij BFG40049 CO T05- 19 SAMPLING DATA SHEET (One Sample Per Oata Sheet) PROJECT:_____________ SITE:________________ LOCATION:____________ INSTRUMENT MODEL NO: PUMP SERIAL NO:_____ SAMPLING DATA _____ _____ _____ OATE(S) SAMPLED:____ TIME PERIOD SAMPLED: OPERATOR:____________ CALIBRATED BY: :T1me Sample Number:____________ Start Time: __________ Stop Time: Dry Gas Meter Reading Flow Ambient Barometric Rotameter Rate,*Q Temperature Pressure. Relative Reading ml /Min c mrnHg Humidity, X Conwents 1. 2. 3. 4. N. Total Volume Data** Vm (Final * Initial) Dry Gat Meter Reading, or Liters _ Qi 0? Q3...QN _ 1 _ _____ "N * 1000 x tSampling Time in Minutes) Liters * Flowrate from rotameter or soap bubble calibrator (specify which). ** Use data from dry gas meter If available. FIGURE 2. EXAMPLE SAMPLING DATA SHEET BFG40050 TOS-20 I j e BFG40051 :r s 3 TOS-21 TYPICAL tIPLC CHROMATOGRAM Column - Zorbax ODS, 250 x 4.6 mm Mobile Phase - 80/20 Methanol/II2O Flow Rate - I mL/HInutc Detector - UV at 370 nm 3i \t .G :s I 9U0UX3l|013^3 FIGURE 4. ieu*au9d ap/qapiazuag - ap^qapiuoaoa3 auoaaav --= ivuoidou^ u^aiousv -- ap/qapinas* -- apAqapieuuoj ,*'i i - ' ii11 * e ''j _ <5 D .Q (O <o G ru BFG40052 3. Organic Acids OSHA - 38 Dow Chemical Modifications (for Formic, Acetic and Acrylic Acids) BFG40053 ACHYLIC ACIO Method no.: 28 Matrix: Air Target concentration: 2 ppm (5.9 mg/m') see Toxic Effects Section 1.1.2. Procedure: Samples are collected* by drawing a known volume of air through two XAD-8 sampling tubes connected in series. Samples are desorbed with l/l methanol/water and analyzed by high performance liquid chromatography (HPLC) using an ultraviolet (UV) detector. Recommended air volume and sampling rate: 24 L at 0.1 L/min Detection limit of the overall procedure: (Based on the recommended air volume) 0.014 ppm (0.042 mg/m1) Reliable quantitation limit: 0.014 ppm (0.042 rag/m1) Standard error of estimate at the target concentration: (See Table 4.8.1. and Figure 4.8.1.) 7.134 Status of method: A sampling and analytical method which has been subjected to the established evaluation procedures of the Organic Methods Evaluation Branch. Date: April, 1981 Chemist: Kevin Cummins Organic Methods Evaluation Branch OSHA Analytical Laooratory Salt Lake City, Utah BFG40054 1. General Discussion 1.1. Background 1.1.1. History of procedure A numoer of analytical methods are reported in tine literature for the analysis of acrylic acid. Although a polarographic method has been published, most of these methods involve either gas, liquid, or paper chromatographic techniques (Ref. S.I.). A direct method of analysis using reverse phase high performance liquid chromatography was developed and used in thi3 study. This method is sensitive, selective, and easy to apply, and it also permits the simultaneous analysis of a numoer of other acrylate monomers and acrylic acid precursors. A previous attempt by Brown to use octadecasilane (ODS) based HPLC columns for the analysis of acrylic acid was unsuccessful (Ref. 5.2). It has been recognized in this laboratory for some time that polar molecules of low molecular weight can often be retained and chromatographed in the reverse phase mode using Zorbax ODS packed columns and a high percent of water in the mobile phase. This method, when coupled with an ion suppression technique, proved successful for the retention and separation of acrylic acid. A retention time of approximately six minutes is obtained with a Dupont Zorbax ODS eight-micron, silica packed column and a 96/H, water/acetonitrile mobile phase containing 0.15 by volume of phosphoric acid. The phosphoric acid serves to suppress the ionization of acrylic acid resulting in. the retention of the undissociated form of the molecule. Under these conditions acrylic acid is separated from the potential interferences: methacrylic acid, acrylamide, acrolein, acrylonitrile, and acetic acid. Propanoic acid, a saturated precursor of acrylic acid, can be resolved from acrylic acid in a 13 minute analysis at 1 mL/min flow rate using a 0.15 aqueous phosphoric acid mobile base. Acrylic acid, because of its unsaturated nature, is approximately 100 times more sensitive at 210 nm on a weight basis than propanoic acid. This method permits the detection of acrylic acid in the presence of very high levels of propanoic acid. No published data was found regarding a collection method for acrylic acid from air. In a personal communication, it was reported that silica gel tubes coated with either hydroqulnone or p-methoxyhydroqulnone were being evaluated as a means of sampling acrylic acid in air (Ref. 5-1*-)Both of these compounds are commonly used in the acryllc- c.n 03 Ool 28-1 BFG40055 acrylate industry to prevent polymerization of a variety of monomeric substances. Ho decomposition of acrylic acid was observed in evaluations performed at this laboratory using either hydroquinone treated or untreated silica gel tubes. It should be noted, however, that the standard used in this evaluation contained low, unspecified levels of p-methoxyhydroquinone inhibitor. Further evaluations indicated that some problems with the retention of acrylic acid on 5KC silica gel tuoes could arise if air sampling is being performed for nn extenoed time in humid atmospheres. No loss of acrylic acid from the front section of a silica gel tube occurred if 80% relative humidity air was sampled for one hour at a 0.1 L/min flow rate. With longer sampling times, a considerable migration from the front section of tne sampling tube was observed. When 46.7 ug of acrylic acid in methanol was spiked Into an atmosphere ahead of two silica gel tubes mounted in series, and humid air was drawn through the system for four hours at a 0.1 L/min flow rate, only 151 of the total analyte was retained on the front section of the first silica gel tube. (See Backup Data Section 4.9., Table 4.9.) Differences in retention efficiency between two different lots of SKC silica gel tubes are also apparent from this data. The recently purchased lot 119 silica gel tubes are less effective in retaining acrylic acid in a humid atmosphere than the older SKC silica gel tubes which do not have a lot number designation. (See Backup Data Section 4.9., Table 4.9.) In addition to silica gel, several other solid sorbent materials were determined to be inadequate for sampling acrylic acid. Low desorption efficiencies were obtained Tor both charcoal and Porapak T sorbents using various ratios of methanol and water to desorb the spiked tubes. XAD-2 and XAD-4, both non-polar, styrene-divlnyl benzene copolymers, gave 100% desorption efficiencies using methanol. However, neither of these two sorbents were totally effective in retaining acrylic acid when humid air was sampled. Six XAD-2 tubes retained an average of only 60% of 120 ug acrylic acid spikes when 80% relative humidity air was drawn through each tube for three hours at a 0.1 L/min flow rate. Although more effective in retaining acrylic acid than XAD-2, the higher surface area XAD- sorbent still lost an average of 20% of a 327 ug acrylic acid spike when 80% relative humidity air was drawn through duplicate sample tubes at a 0.1 L/min flow rate for 7.5 hours. Further studies on the collection of acrylic acid from air indicated that the solid sorbent, XAD-8, an acrylic ester polymer, was quite effective in collecting and retaining acrylic acid. 28-2 BFG40056 Amounts equivalent to twice the target concentration for a four-hour air sample (327 ug) could be spiked into an atmosphere anead of the sampling tube and effectively collected and recovered after 80J relative humidity air is drawn through the tube for four hours at 0.1 L/min. No breakthrough onto a second tube mounted in series was observed for acrylic acid collected from a spiked atmosphere, even though 805 relative humidity air was drawn through the system for 8 hours. Similar results were observed when relatively dry laboratory air was sampled. (See Backup Data Section *.5.) Although no problems were encountered with the use of XAD-8 in sampling for acrylic acid, it should be noted that there exists a similar polymeric acrylic ester, XAD-7, which because of its higher surface area may be a more effective sampling media for low molecular weight, polar substances. (Ref. 5.5) However, based on the evaluation procedures performed to date, an XAD-8 sorbent packed tube Is currently recommended as the sampling media for acrylic acid in air. 1.1.2. Toxic Effects (This section is for information only and should not be taken as the basis of OSHA policy). Acrylic acid is an acute local irritant. Exposure to its vapors can produce an irritating effect to the skin, eyes, nasal and bronchial passages. (Ref. 5.3.) An exposure of 300 ppm for six hours per day for 20 days resulted in nasal irritation, lethargy, and weight loss in three male and tnree female rats. A one time, five-hour exposure at saturated conditions (6000 ppm) produced nose and eye irritation, respiratory impairment, and death in one of four exposed rats. (Ref. 5.6.) A large variability in the LD, value is reported for both rabbits and mice. LDS, values for a single skin application ranging from 295 mg/kg bw (body weight) to 950 mg/kg bu are reported in rabbits. Oral LD,* values ir. rats vary from 193 mg/kg bw to 3200 mg/kg bw. (Ref. 5.1.) In a fetal rat toxicity study conducted by Singh, et al, a dose related increase in the incidences of skeletal abnormalities, reduced birth weights, and resorptions was observed with exposure of pregnant rats to acrylic acid. (Ref. 5.7.) The authors note however, that the effects observed by acrylic acid and several methacrylate esters were not as pronounced as was observed for phthalate ester treated rats in previous studies. C/t *0 ce 28-3 BFG40057 V The International Agency for Research in Cancer (IARC) reports that there is no data available regarding the carcinogenic potential of acrylic acid, and recommends study in this area. (Ref. 5.1.) The recommended target concentration of 2 ppm is based on the results of a recent industry sponsored subchronic- inhalation study of mice and rats. A slight focal degeneration of the olfactory mucosa was observed in a portion of the mice exposed to 5 ppm acrylic acid for 90 days. The 2 ppm level is a suggested TWA exposure limit of the Health and Safety Division of Rohm and Haas. (Ref. . 5.8.) 1.1.3. Exposure Exposure to acrylic acid vapors is primarily confined to production processes since most acrylic acid is used as a precursor in the production of a variety of different acrylates. The alkyl esters of acrylic acid are used to produce a number of products including acrylic fibers, . emulsion and solution polymers, and surface coatings. Some of the free acid is used to produce polyacrylic acid, which has industrial uses as a thickener, flocculant, and binder. In 1976 three U.S. companies reported a production of 116.5 million kg of acrylic acid. (Ref. 5.1., 5.3.) 1.1.4. Physical Properties (Ref. 5.9. unless otherwise Indicated) M.W.: 72.06 ' Solubility: Miscible In alcohol and ether. Soluble in acetone and benzene. B.P.: 14i*C at 760 mm Flash Point: 155*F (Ref. 5.10.) Cleveland open cup. Specific Gravity: 1.05 ( 20/4*0 Color: Clear, colorless (Ref. 5.10.) Odor Pungent, irritating, odor resembling acetic acid. (Ref. 5.10.) Formula: H,C-CHCOOH Synonyms: Acroieic acid, propcnoic ethylene carboxylic acid, propene acid, vinyl formic acid (Ref. 5.11.) 28-K BFG40058 1.2. Limit defining parameters 1.2.1. Detection limit of the analytical procedure The detection limit of the analytical procedure is 5 ng per injection. This is the amount of analyte which win give a peak whose height is five times the amplitude of the baseline noise. (See Backup Data Section U.i., Figure 4.2.). 1.2.2. Detection limit of the overall procedure The detection limit of the overall procedure is 1 ng per sample (0.014 ppm/0.042 mg/m'). This is the amount of analyte spiked on the sampling device which allows recovery of an amount of analyte equivalent to the detection limit of the analytical procedure. (See backup data section 4.2.) 1.2.3. Reliable quantitation limit The reliable quantitation limit Is 1 ug per sample (0.014 ppm/0.042 mg/m1). This is the smallest amount of analyte which can be quantitated within the.requirements of 75' recovery and 955 confidence limits of 255. (See Backup Data Section 4.3.) It must be recognized that the reliable quantitation limit and detection limits reported in the method are based upon optimization of tne instrument for the smallest possible amount of analyte. When the- target concentration of an analyte is exceptionally higher than these limits, they may not be attainable at the routine operating parameters. In this case, the limits reported on analysis reports will be based on the operating parameters used during the analysis of the samples. 1.2.4. Sensitivity The sensitivity of tne analytical procedure over a concentration range representing 0.5 to 2 times the target concentration based on the recommended air volume is 12,415 area units per ug/mL. The sensitivity is determined by the slope of the calibration curve. (See Backup Data Section 4.M., Figure 4.4.) The sensitivity will vary somewhat with the particular instrument used in the analysLs. 20-5 BFG40059 C/T 05 C/7 O do 1.2.5. Recovery The average recovery from spiked samples over the range of 0.5 to 2 times the target concentration is 1025. (See Backup Data Section Table 4.7.) The recovery of analyte from the collection medium must be 755 or greater. 1.2.6. Precision (Analytical method only) The pooled coefficient of variation obtained from eight replicate determinations of analytical standards at 0.5X, IX and 2X the target concentration is 0.0085. (See Backup Data Section 4.6.) 1 .2.7. Precision (Overall Procedure) The overall procedure must provide results at the target concentration that are 255 or better at the 955 confidence level. The average precision at the 955 confidence level for the ambient storage tests is 145. (See Backup Data Section Figure 4.8.1. and Table 4.8.1.) This includes an additional 55 for sampling error. 1.3. Advantages 1.3.1. The sensitivity of the analytical method permits sampling times as short as 15 minutes. 1.3.2. HPLC analysis of acrylic acid is rapid, direct, and sensitive. 1.3.3. Reanalysis of samples is possible. 1.4. Disadvantages The method has not been field tested at this time. 2. Sampling Procedure 2.1. Apparatus 2.1.1. A personal sampling pump which can be calibrated to within 55 of tne recommended 0.1 L/min flow rate while the sampling tubes are in line. 2.1.2. Class tubes of *- to 5-cm length with a 4-nra ID and a 6-mm 00 are packed ttn approximately 100 mg of XAD-8 solid sorbent of 16-50 mean site. Small sllanized glass wool plugs on eacn cna of the tube are used to retain the sorbent. These packed XAD-8 tubes are currently available from the laboratory upon request. 23-6 BpG40060 April 6,1990 Dr. Rafael Moure University of Lowell METHOD FOR THE ANALYSIS OF ORGANIC ACIDS IN AIR Dear Dr. Moure: This is a brief description of the organic acids analysis method that we discussed on the phone earlier today. Formic, acetic, and acrylic adds can be collected simultaneously on silica gel tubes (700 mg front/300 mg back), with a flow of about 100 mL/mln. The acids are then desorbed using de-ionized water (typically 10 mL), with a 1-hou. 'action '-..ite (we use a flatbed shaker). We have typically seen reco\ a excess of 90%/ but we always run some spiked tubes with our sam: confirm the recoveries. fht? extraction solvent is then analyzed using high-performance liquid chromatography (HPLC). The column we have found to work the best is on Aminex HPX-87H ion exclusion column (7.8 x 300 mm), which is manufactured by Bio-Rad Laboratories (32 nd Street, Richmond, CA 94804, catalog # 125-0140). The eluent was 0.01 N H2SO4 at a flow'of 1 mL/mln. U.V. detection at 208 run was used, which was fed into our laboratory data system. Retention times for formic, acetic and acrylic adds were about 8.4, 9.3, and 11.8 minutes, respectively. The limit of detection for formic and acetic acid was about 1 ng/mL in solution, while the LOD for acrylic acid was about 0.1 jig/mL. With a desorption volume of 10 mL and an air sample volume of about 20 L, the corresponding LOD's In air are around 0.2 ppm and 0.02 ppm, respectively. Some epresentative chromatograms are shown on the next page. If you have any further questions, please do not hesitate to give me a call. inr^r^l v. 1. H&ES Analytical Chemistry The Dow Chemical Company 1803 Building Midland, MI 48674 (517) 636-0629 0S8ZSZ BpO4006/ 4. Aerosol Sampling Total Dust NIOSH -0600 BpG40062 FORMULA: The respirable fraction of the dust mass, as specified by the . American Conference of Governmental Industrial Hygienists [1] NUISANCE DUST, RESPIRABLE ~-- " METHOO: 0600 ISSUED: 2/1S/84 OSHA: 5 mg/m* NIOSH: no standard ACGIH: 5 mg/m* PROPERTIES: Penetrates the non-ci1iated portions of the lung; quartz less than 1* SYNONYMS: boron oxide (CAS #1303-86-2) and nuisance dusts [2], including aluaina (CAS *1344-26-1), calciun carbonate (CAS *1317-65-3), cellulose (paper fiber; CAS *9004-34-6), glycerin mist (CAS #56-81-5), limestone (CAS *1317-65-3), etc. SAMPLING MEASUREMENT SAMPLER: CYCLONE FILTER (10-nrn Oorr-Oliver cyclone tared 5-v*n PVC menbrane) TECHNIQUE: GRAVIMETRIC (FILTER WEIGHING) ANALYTE: mass of respirable dust fraction flow RATE: 1.7 L/min VOL-MIN: 75 L 8 5 mg/m* -MAX: 1000 LBS mg/m* SHIPMENT: routine BALANCE: 0.01 mg sensitivity or better; use same balance before and after sanple collection CALIBRATION: National Bureau of Standards Class N weights SAMPLE STABILITY: indefinitely BLANKS: 2 to 10 field blanks per set RANGE: 0.3 to 2 mg per sanple ESTIMATED LOO: 0.2 mg per sanple ACCURACY PRECISION: 68 pg with 0.01-mg sensitivity balance [5] RANGE STUDIED: 0.5 to 10 mg/m* (lab and field) BIAS: depends on dust size distributions [3] OVERALL PRECISION (sr): 0.043 to 0.145 (lab); 0.144 to 0.227 (field) [4] APPLICABILITY: The method measures the mass concentration of any non-volatile respirable <hist. Besides inert dusts [)), the method is recommended for respirable coal dust, which has an OSHA PEL * 2.4 mg/m*. The method may be biased where the respirable fraction is defined by the 8ritish Medical Research Council's criteria or the W1E horizontal elutriator [4], INTERFERENCES: Larger than respirable particles (over 10 t) have been found in seme cases by microscopic analysis of cyclone filters. Over-sized particles in the sanple are known to be caused by inverting the cyclone assembly. Heavy dust loadings, charged particles, fibers and water-saturated dusts also interfere with the cyclone's size-selective properties.__ OTHER HETHOOS: This method is based on and replaces Sanpling Data Sheet <29.02 [6].-------------- _ 2/15/04 0600-1 BFg40063 c c ifT iry O 'V NUISANCE OUST, RESPIRABLE HETHOO: 0600 EQUIPMENT: 1. Sanpler: a. Filter: 37-mn diameter, 5.0-ym pore size, polyvinyl chloride filter or equivalent hydrophobic menbrane filter supported with backup pad in a two-piece, 31-am cassette filter holder held together by tape or cellulose shrink band. b. Cyclone: 10-rnn Dorr-Oliver nylon cyclone. c. Sanpling head holder: this holder must keep the cassette, cyclone and coupler together rigidly so that air enters only at the cyclone inlet. 2. Personal sanpling punp, 1.7 L/min St, with flexible connecting tubing. NOTE: Pulsation in tlie punp flow must be within + 201 of the mean flow. 3. Balance, analytical, with sensitivity of at least 0.01 mg. A more sensitive balance will be necessary for substances with PEL'S below I mg/m*. 4. Static neutralizer, e.g., Po-210; replace nine months after the production date. 5. Environmental chanter for balance, e.g., 20 *C + 0.3 *C and SOI * St RH. 6. Vacuun desiccator. SPECIAL PRECAUTIONS: None. PREPARATION OF SAMPLERS BEFORE SAMPLING: 1. Dry filters and backup pads under vacuun in the vacuum desiccator for at least IS min. 2. Release the vacuun, remove the desiccator cover, and equilibrate the filters in the environmental chanter for at least 1 hr. 3. Hunter the backup pads with a ballpoint pen and place them, mattered side down, in filter cassette bottom sections. 4. Weigh the filters in the environmental chanter. Record the filter tare weight, Wj (mg). a. Zero the balance before each weighing; b. Handle the filter with forceps (nylon forceps if further analyses will be done); and c. Pass the filter over an antistatic radiation source. Repeat this step if filter does not release easily from the forceps or if filter attracts balance pan. Static electricity can cause erroneous weight readings. 5. Place the weighed filters on top of the backup pads in- the filter cassette bottom sections and allow to stand an additional 8 to 16 hrs in the environmental chanter. 6. Reweigh the filters. If this tare weight differs by more than 0.01 mg from the first tare weight obtained in step 4 above, discard the filter. ` NOTE: Insert a rod through the outlet hole of the filter cassette bottom section to raise the backup pad and filter so that the filter can be grasped with forceps. 7. Assert))e the filters in the filter cassettes and close firmly so that leakage around the filter will not occur. Ptace a plug in each opening of the filter cassette. Place a cellulose shrink band around the filter cassette, allow to dry, and mark with the same nurter as the backup pad. 8. Remove the cyclone's grit cap and vortex' finder before use and inspect the cyclone interior. If the inside is visibly scored, discard this cyclone since the dust separation characteristics of the cyclone might be altered. Clean the.interior of the cyclone to prevent reentrainment of large particles. 9. Assent)le the sanpler head. Check alignment of filter holder and cyclone in the sanpling head to prevent leakage. 2/1S/84 0600-2 METHOD: 0600 NUISANCE OUST. RESPIRABLE SAMPLING: 10. Calibrate each personal sanpling puip to 1.7 l/mjn with a representative sampler In line. 11. Sartple at 1.7 l/min for 45 min to 8 hrs (76 to 816 L). Oo not exceed 5 mg dust loading on the filter. 'i NOTE: Do not allow the sampler assembly to be inverted at any time. Turning the cyclone to anything more than a horizontal orientation may deposit over-sized material from the cyclone body onto the filter. SAMPLE PREPARATION: 12. Wipe dust from the external surface of the filter cassette with a moist paper towel to minimize contamination. Oiscard the paper towel. .13. Remove the top and bottom plugs from the filter cassette. Place the filter cassettes in a vacuun desiccator under vacuum for at least 15 min, followed by equilibration for at least 1 hr in the environmental chamber. 14. Remove the filter cassette band, pry open the filter cassette, and remove the filter by inserting a rod in the outlet hole of the filter cassette. Handle the filters very gently by the edge to avoid loss of dust. NOTE: If the filter sticks to the underside of the cassette top, very gently lift away by using the dull side of a scalpel blade. This must be done carefully or the filter will tear. CALIBRATION AND QUALITY CONTROL: 15. Zero the microbalance before all weighings. Use the same microbalance for weighing filters before and after sample collection. Calibrate the balance with National Bureau of Standards Class H weights. 16. Take two to four replicate sanples for every batch of field sanples for quality assurance on the sanpling procedures. The set of replicate sanples should be exposed to the sane dust environment, either in a laboratory dust chanber [7] or in the field [8]. The quality control sanples must be taken with the same equipment, proce&res and personnel used in the routine field sanples. Calculate precision fran these replicates and record sr on control charts. Take corrective action when the precision is out of control [7]. MEASUREMENT: 17. Weigh each filter, including field blanks. Record this post-sanpling weight, Wj beside its corresponding tare weight. Record anything remarkable about a filter (e.g., visible particles, overloaded, leakage, wet, tom, etc.). CALCULATIONS: 18. Calculate the concentration of respirable nuisance (tost, C (mg/m*), in the air volune sanpled, V (L): -- (",-!) B. in. ' where: Wj tare weight of filter before sanpling (mg) W2 e post-sanpling weight of sample-containing filter (mg) 8 mean change in field blank filter weights between tare and post-sanpling (mg) ( or -). C/T .09 b r 2/15/84 0600-3 BFG40065 HUISAUCE OUST. RESPIRABLE HETHOO: 0600 EVALUATION OF HETHOO: 1. Bias. In respirable dust measurements, the bias in a sanple is calculated relative to the appropriate respirable dust criterion. The theory for calculating bias is developed by Bartley and Breuer [3]. For this method, the bias, therefore, depends on the ACGIH criterion for respirable dust, the cyclone's penetration curve at 1.7 L/min flow rate, and the size distribution of the ambient dust. Based on the cyclone's penetration curves for non-pulsating flow measured with a monodisperse aerosol by Caplan, Doemeny and Sorenson [9], the bias in this method is shown in Figure 1. For dust size distributions in the shaded region, the bias in this method lies within the >0.10 criterion established by NIOSM for method validation. Bias larger than > 0.10 would, therefore, be expected for many workplace aerosols, especially those with small mass median diameters. However, bias within * 0.20 would be expected for dusts with geometric standard deviations greater than 2.0, which is the case in most workplaces. Bias can also be caused in a cyclone by the pulsation of the personal sampling purp. Bartley, et al. [10] showed that cyclone samples with pulsating flow can have negative bias as large as -0.22 relative to samples with steady flow. The magnitude of the bias depends on the amplitude of the pulsation at the cyclone aperture and the dust size distribution. For punps with instantaneous flow rates within 201 of the mean, the pulsation bias is less than -0.02 for most dust size distributions encountered in the workplace. Electric charges on the dust and the cyclone will also cause bias. Briant and Moss [11] have found electrostatic biases as large as -SOI, and show that cyclones made with graphite-filled nylon eliminate the problem. 2. Precision. In a recent review [4], the overall cyclone precision is shown to be most sensitive to two factors: the .analytical precision and the sampling procedures,, particularly the quality control system used in the maintenance and calibration of samplers. Theoretically, the variance for the overall precision is the sun of the variances fran the sampling and analysis. The analytical variance depends on the dust loading on the filter. For the dust loading in an 8-hr sanple above 1.5 mg/m*, Botman, et al. [4] find that the empirically determined sampling error dominates this analytical error. Because of the effects of the environment, precision estimates for dust samplers are much more variable than those reported for gas and vapor sanpling. In laboratory tests with 0.01 mg sensitivity balances, the overall precision of a single respirable dust sample has relative standard deviations (sr) from 0.043 to 0.14S over concentrations ranging from 0.5 to 5 mg/m*. In the laboratory studies where the Aist concentrations in the test chanber are more carefully controlled, the estimated sP is less than 0.091, which is the target precision value for a bias e^jal. to 0.10 in the NIOSH validation criteria. In the field tests with 0.01 mg sensitivity balances, precision estimates range from 0.144 to 0.227 over concentrations ranging from 1 to 10 mg/m*. Whether the larger sP values in field tests are due to sampler performance or to more inhomogeneous dust concentrations in the field tests cannot be determined from existing data. 2/15/84 0600-4 BpG40066 HSTHOQ: 0600 NUISANCE DUST. RESPIRABLE REFERENCES: [1] TLVs - Threshold Limit Values for Chemical Substances and Physical Agents in the Work Environment with Intended Changes for 1983-84, 38, ACGIH. Cincinnati, OH (1983). [2] Ibid, Appendix 0, 52. [3] Bartley, 0. L. and G. N. Breuer. Analysis and Optimization of the Performance of the 10-ntn Cyclone, Am. Ind. Hyq. Assoc. J., 43, 520-528 (1982). [4] Bowman, J. 0., 0. L. Bartley, G. H. Breuer and S. A. Shulman. The Accuracy of Sampling Respirable Coal Nine Oust, Draft NI0SH report (1983). [5] Parobeck, P.. T. F. Torrb, H. ICu and J. Cameron. Measurement Assurance Program for the Weighings of Respirable Coal Nine Oust Sanples, J. Qua). Tech.. 13, 157 (1981). [6] NI0SH Manual of Sanpling Data Sheets, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 77-159 (1977). [7] Bownan, J. 0., 0. 1. Bartley, G. N. Breuer, l. J. Ooemeny and 0. 3. Murdock. Accuracy Criteria Reccmnended for the Certification of Gravimetric Coal Nine Oust Personal Samplers, NIOSH report (in press, 1983). [8] Breslin, 3. A., S. 0. Page and R. A. Jankowski. Precision of Personal Sampling of Respirable Oust in Coal Nines, U.S. Bureau of Nines Report of Investigations #8740(1983). [9] CapIan, K. J., L. J. Ooemeny and S. Sorenson. Evaluation of Coal Nine feist Personal Sanpler Performance. Final Report. NIOSH Contract No. PH CPE-r-70-0036 (1973). [10] Bartley, 0. 1.. G. N. Breuer, P. A. Baron and J. 0. Bornean. Punp Fluctuations and Their Effect on Cyclone Performance, submitted to the Am. Ind. Hyq. Assoc. J. (1983). [11] Briant, 0. K. and 0. R. Moss. The Influence of Electrostatic Charge on the Performance of 10-rnn Nylon Cyclones, American Industrial Hygiene Conference (1983). METHOD WRITTEN BY: Joseph Bownan, Ph.D., CIH, NIOSH/OPSE. > . 2/15/84 0600-5 bFG40067 MASS MEDIAN DIAMETER pm)( GEOMETRIC STANDARD DEVIATION Figure 1. Bias in respirable (Just determination 2/15/84 0600-6 BFG40068 4. Aerosol Sampling Benzene Soluble Particulate NXOSH - 5023 BFG40069 *28038232: FORMULA: various organic-soluble coepounds Cl.2.3] N.W.: various COAL TAR PITCH VOLATILES METHOO: 5023 ISSUED: 5/IS/8S OSIIA: 0.2 mg/m* (benzene-solubles) HIOSH: 0.1 mg/m*/10 hr (cyclohexane-solubles) [2,3] ACGIH: 0.2 mg/m* (benzene solubles) [4] PROPERTIES: liquid; d -1.06 g/mL 9 38 *C; 60 to 8SI distills 9 <355 *C [5]; creosote distills 9 210 to 385 *C [2] SYNONYMS: benzene-solubles, cyclohexane-solubles, coal tar pitch volatiles (CAS #8007-45-2). creosote from coal tar. SAMPLING MEASUREMENT SAMPLER: FILTER (2-pm, 37-mm PTFE membrane) FLOW RATE: 1 to 4 L/min VOL-HIN: 500 L 9 0.2 mg/m* -MAX: 2400 L SHIPMENT: routine SAMPLE STABILITY: unknown FIELO BLANKS: 101 (>2) of samplers TECHNIQUE: GRAVIMETRIC ANALYTE: organic-solubles (includes anthracene, benzanthracene, benzo(a)pyrene. carbazole, chrysene, phenanthrene, pyrene and others [1,2,3,4]) EXTRACTION: benzene, cyclohexane or other appropriate solvent; ultrasonic 20 min CALIBRATION: National Bureau of Standards Class H weights ACCURACY RANGE STU0IE0: not studied BIAS: unknown RANGE: 0.1 to 2 mg per sarrple ESTIMATED LOO: 0.05 mg per sanple [6] PRECISION (sr): 0.02 at 1.35 mg [6]; 0.23 for blanks [6] OVERALL PRECISION (sr): not determined APPLICABILITY: The working range is 0.1 to 2 mg/m* for a 1000-1 air sample. The method is useful for air monitoring of coke oven snissions, petrolein contnistion products such as diesel emissions, and petroleun asphalt funes. The method may be applied to bulk samples. The method is non-specific and measures alt substances in the sample which are soluble in the solvent selected and which can be desorbed from particulate matter present on the filter. INTERFERENCES: Changes in temperature or hunidity during pre- and post-collection weighing affect accuracy. Losses may occur due to volatilization of collected aerosol Airing or after sanpling. OTtCR MEIH005: This method modifies and conOines P4CAN 217 [1] and the criteria docurent method [2]. 5/15/85 5023-1 BFG40070 COAL TAR PITCH VOLATILES REAGENTS: 1. Solvent: Benzene,* cyclohexane or other solvent, reagent grade. 2. Oichromic acid cleaning solution. 3. Acetone, reagent grade. 4. Hexane. See SPECIAL PRECAUTIONS. HSTHOO: 5023 EQUIPMENT: 1. Sampler: PTFE laminated menferane filter. 2-\*s pore size, 37-rnn diameter (Zeflour, Nenbrana Inc., Pleasanton, CA or equivalent) backed by a gasket (37 mm 00, 32 nrn ID) cut from a cellulose support pad in plastic filter holder. 2. Personal sanpling purp, 1 to 4 L/minj with flexible connecting tubing. 3. Ultrasonic bath. 4. Nicrobalance, readable to ) pg, with' N8S Class M weights. 5. Environmental chamber for balance, e.g., 20 #C 0.3 *C and 501 *51 relative hunidity. 6. Weighing cups, PTFE, 2-mL, approximate tare weight 60 mg, in metal rack. 7. Vacuus oven. NOTE: Keep the interior of the vacuus oven dust-free for maximun sensitivity, reproducibility, and accuracy. 8. Forceps. 9. Test tubes, PTFE-lined, screw cap, 13 mn x 100 (tin.* 10. Filter, O.S-jxs (Hillex-SR, Mi11{pore Corp., Bedford, M4 or equivalent). 11. Pipets, 1- and 5-L.* Rinse with distilled water, acetone, and hexane; dry. , I SPECIAL PRECAUTIONS: Benzene and coal tar pitch volatiles are suspect carcinogens [1,2,3,4]. SAMPLING: , 1. Calibrate each sanpling punp with a representative sampler in line. 2. Sample at an accurately known flow rate between 1 and 4 L/min for a total sanple volume of 500 to 2400 L. Do not exceed a filter loading of ca. 2 mg total particulate. 3. Replace caps in cassette and ship to laboratory. SAMPLE PREPARATION: 4. Transfer filter carefully using forceps to test tube. Add 5.0 mL solvent via pipet. Cap the tube. NOTE 1: Cyclohexane is recommended as solvent because of the carcinogenic potential of benzene (2}. NOTE 2: This extraction is also applicable to bulk samples (ground and sieved to ca. 250 in). Extract 250 mg bulk sample with S O mL solvent. 5. Place tube upright in beaker containing water to the same level as the liquid in the tube. Place beaker and tube in ultrasonic bath Sonicate for 20 min. 6. Filter solution through a 0.5-pm filter into a clean, preweighed weighing cup. Oiscard the filter. NOTE: An aliquot of the solution may be taken at this step if other analyses (e.g.. polynuclear aromatic hydrocarbons) are to be performed on the sample. Apply the appropriate aliquot factor in calculations. 5/15/05 5023-2 BFG40071 METHOO: 5023 COAL TAR PITCH VOLATHFC CALIBRATION ANO QUALITY OONTROL: 7. Zero the microbalance on the 1.0 mg range and calibrate per balance manufacturer's directions. NOTE: Perform weighings at constant temperature and relative humidity. 8. Process three blank filters through the extraction and measurement procedures. MEASUREMENT: 9. Transfer via pipet a 1.0-mL aliquot of sample extract to a preweighsd weighing cup. 10. Place weighing cup in vacuun oven preheated to 40 *C. Apply vacuUn until pressure in the oven is 7 to 27 kPa (50 to 200 irm Hg). Allow solvent to evaporate for 2 hrs. Release vacuun by slowly opening release valve which has an in-line filter to remove roam dust. 11. Equilibrate the weighing cup to the tenperature and relative huaidity of the balance roan for at least 30 min. Weigh the weighing cup to the nearest microgran. CALCULATIONS: 12. Oetermine the mass of organic-soluble residue found in the sample, W (yg), and in the average media blank, 8 (yg). 13. Calculate concentration, C, of organic-solubles in the air volune sanpled, V (L): C (w *j mg/m*. EVALUATION Of METH00: Several benzene extracts of samples of a! uni nun reduction plant emissions were combined to give a solution containing 1.35 mg of benzene-soluble material per sample; nine aliquots of this solution gave residue weights with a relative standard deviation of 0.02. Benzene extracts of six blank filters gave residue weights with a relative standard deviation of 0.23 (?]. REFERENCES: [1] NIOSH/OSHA Occupational Health Guidelines for Chemical Hazards, Coal Tar Pitch Volatiles, U.S. Department of Health and Hunan Services, Publ. (NIOSH) 81-123 (1981), available as GPO Stock fO17-033-00337-8 from Superintendent of Documents, Washington, DC 20402. [2] Criteria for a Recanmended Standard ... Occupational'Exposure to Coal Tar Products, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 78-107 (1978). [3] Criteria for a Recommended Standard ... Occupational Exposure to Coke Oven Emissions, U.S. Department of Health, Education, and welfare, Publ. (NIOSH) 73-110)8 (1973). [4] Oocuicntation of the Threshold Limit values, 4th ed., American Conference of Governmental Industrial Hygienists, Cincinnati, oh (1981). [5] The Merck Index, 9th ed., 2563, Merck & Co.. Rahway. NO (1976). [6] UBTL Report, NIOSH Sequences #4229-T.U.V (unpublished, April 27, 1984). [7] NIOSH Manual of Analytical Methods, 2nd ed.. Voi. 1, P4CAM 217, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 7 7- 15 7-A (19/7). METHOO REVISED BY: B. R. Bel inky. NIOSU/OPSC. 5/15/85 5023-3 4. Aerosol Sampling * Lead NIOSH - 7082 BFG40073 W $5 r r> lj FORMULA: Pb H.U.: 207.19 (Pb); 223.19 (PbO) METHOD: ISSUEO: LEAD 7082 2/15/84 OSHA: 0.05 mg/m* NIOSH: 0.05 mg/m* tH ACGIH: 0.15 mg/m*; STEL 0.45 mg/m* PROPERTIES: soft kUI; d 11.3 g/cm*; HP 327.5 *C; valences *2, *4 in salts SYNONYMS: vary depending upon Uie chemical form (elemental lead and lead compounds except alkyl lead); CAS f1317-36-8 (POO); CAS #7439-92-1 (Pb). SAMPLING MEASUREMENT SAMPLER: FILTER (0.8-urn cellulose ester menbrane) FLOW RATE: 1 to 4 L/min VOL-MIN: 200 L 8 0.05 mg/m* -MAX: 1200 L TECHNIQUE: ATOMIC ABSORPTION, FLAME ANALYTE: lead ASHING: cone. HNOg, 6 ML; 140 *C FINAL SOLUTION: 101 HNO3, 10 mL SHIPMENT: routine FLAME: air-acetylene, oxidizing SAMPLE STABILITY: stable WAVELENGTH: 283.3 nm BLANKS: 2 to 10 field blanks per set BACKGROUND CORRECTION: Oj Of H2 lamp ACCURACY RANGE STU0IE0: 0.13 to 0.4 mg/m* [2]; 0.15 to 1.7 mg/m* (fune) [3] CALIBRATION: Pb++ in 101 HNOg RANGE: 10 to 200 pg per sample [3,8] ESTIHATEO LOO: 2.6 ug per sauple [9] BIAS: not significant [2] PRECISION (sr): 0.03 [2] OVERALL PRECISION (sr): 0.072 [21; 0.068 (fuse) [3] APPLICABILITY: The working range is 0.025 to 0.5 mg/m* for a 400-1 air sample. The method is applicable to elemental lead, including Pb fuse, and all other aerosols containing lead. This is an elemental analysis, not conpound specific. Aliquots of the sanples can be analyzed separately for additional elements. INTERFERENCES: Use O2 or continued background correction to control flame or molecular absorption. High concentrations of calciun, sulfate, carbonate, phosphate, iodide, fluoride, or acetate can be corrected. OTHER NETHOOS: This method combines and replaces P4CAM 173 [8] and S341 [7,9] for lead. Method 7300 (ICP-AES) is an alternate analytical method.Method 7505 is specific for lead sulfide. The following have not been revised: the dithizone method, idtich appears in P&CAM 102 [4) and the lead criteria doctanent [1J; P&CAM 191 (ASV) [5]; and PCCAN 214 (graphite fumace-AAS) [61. ______________________________________ ____________________ 2/15/84 7082-1 BFG40074 LEM) HETHOO: 7062 REAGENTS: ). Nitric acid, cone. 2. Nitric acid, 101 (w/v). Add 100 ml cone. HNO3 to 500 ml water; dilute to 1 L. 3. Hydrogen peroxide, 30t HjOj (w/w), reagent grade. 4. Calibration stock solution, 1000 wg Pb/mL. Comtercial standard or dissolve 1.00 g Pb metal in mininua volute of (HI) HCI and dilute to 1 L with It (v/v) HCI. Store in a polyethylene bottle. Stable > one year. 5. Air, compressed, filtered. 6. Acetylene. 7. Distilled or deionized water. EQUIPMENT: 1. Sampler: Cellulose ester filter, 0.8-tmt pore size, 37-mm diameter; in cassette filter holder. 2. Personal sanpling puip, 1 to 4 L/min, with flexible connecting tubing. 3. Atomic Absorption Spectrophotometer with an air-acetylene burner head. 4. Lead hollow cathode lamp or electrode dischargeless lanp. 5. Regulators, two-stage, for air and acetylene. 6. Beakers, Phillips, 12S at, or Griffin, 50 ml with watcbglass covers.* 7. Volunetric flasks, 10- and 100*1.* 8. Assorted volunetric ptpets as needed.* 9. Hotplate, surface temperature 140* C. 10. Bottles, polyethylene, 100-mL. ''Clean all glassware with cone, nitric acid and rinse thoroughly with distilled or deionized water before use. SPECIAL PRECAUTIONS: Perform all acid digestions in a fume hood.* 1 2 3 4 5 6 7 8 9 10 SAMPLING: 1. Calibrate each personal sampling punp with a representative sampler in line. 2. Sample at an accurately known flow rate between 1 and 4 L/min for up to 8 hrs for TVIA measurements. Do not exceed a filter loading of ca. 2 mg total dust. SAMPLE PREPARATION: NOTE: The following sample preparation gave quantitative recovery (see EVALUATION OF HETH00) [9]. Steps 4 through 9 of Method 7300 or other quantitative ashing techniques may be substituted, especially if several metals are to be determined on a single filter. 3. Open the cassette filter holders and transfer the samples and blanks to clean beakers. 4. Add 3 mL cone. HNO3. and 1 mL 301 H^ and cover with a watchglass. Start reagent blanks at this step. NOTE: If PbOj is not present in the sample, the 301 H^ need not be added [3,9]. 5. Heat on hotplate (140 *C) until most of the acid has evaporated. 6. Repeat two more times using 2 mL cone. HNO3 and 1 mL 301 H^ each time. 7. Heat on 140 *C hotplate until a white ash appears. 8. When saeple is dry, rinse the watchglass and walls of the beaker with 3 to 5 L 101 HNO3. Allow the solution to evaporate to dryness. 9. Cool each beaker and dissolve the residues in 1 mL cone. HNO3. 10. Transfer the solution quantitatively to a 10-mL volumetric flask and dilute to volune with distilled water. NOTE: If the concentration (M) of any of the following is expected to exceed the lead concentration (M) by 10-fold or more, add 1 mL 1 H NajEOTA to each flask before dilution to volute: C0, POJ*. I", F~, CHjCOtT. If Ca** or SOj are present in 10-fold excess, make all standards and samples It (w/w) in La** [8]. 05 .1 O CB Ci 2/15/84 7082-2 BFG40075 METHOO: 7062 LEAP CALIBRATION AND QUALITY CONTROL: 11. Prepare a series of working standards covering the range 1 to 20 yg Pb/mL (1 to 200 yg Pb per sanple) by adding aliquots of calibration stock solution to 100-mL volimetric flasks. Oilute to volume with 101 HNO3. Store the working standards in polyethylene bottles and prepare fresh weekly. 12. Analyze the working standards together with the blanks and sanples (steps 17 and 18). 13. Prepare a calibration graph of absorbance vs. solution concentration (yg/*L). 14. Aspirate a standard for every 10 samples to check for instruaent drift. 15. Check recoveries with at least one spiked media blank per 10 samples. 16. Use method of additions occasionally to check for interferences. MEASUREMENT: 17. Set spectrophotometer as specified by the manufacturer and to conditions on page 7082-1. NOTE: An alternate wavelength is 217.0 nm [10]. Analyses at 217.0 ma have slightly greater sensitivity, but poorer signal-to-noise ratio compared to 283.3 nm. Also, non-atomic absorption is significantly greater at 217.0 nm, making the use of O2 or continuw background correction mandatory at that wavelength. 18. Aspirate standards, samples, and blanks. Record absorbance readings. NOTE: If the absorbance values for the samples are above the linear range of the standards, dilute with 101 HNO3, reanalyze, and apply the appropriate dilution factor in the calculations. CALCULATIONS: 19. Using the measured absorbances, calculate the corresponding concentrations (pg/mL) of lead in the sample, C^, and average media blank, C^, from the calibration graph. 20. Using the solution volines (mL) of the sample, Vs, and media blanks, Vfc, calculate the concentration, C (mg/m*), of lead in the air voluae sampled, V (L): C ^3V>. ^a. EVALUATION Of METHOO: Method S241 [7] was issued on October 24, 1975, and validated over the range 0.13 to 0.4 mg/m* for a 180-L air sample, using generated atmospheres of lead nitrate [2]. Recovery in the range 18 to 72 yg Pb per sample was 981, and collection efficiency of 0.8-urn mixed cellulose ester filters (Hillipore Type AA) was 1001 for the aerosols. Subsequent studies on analytical recovery of 200 yg Pb per sample gave the results [3,9]: Soecies Oioestion Method Analytical Recovery. 1 Pb metal Pb metal PbO PbS PbOj Pb02 Pb in paint* Pb in paint* HNO3 only HNO3 1*03 only HNO3 only "*>3 y ^ *22 HNO3 only HNO3 HjOj 92 4 103 3 93 + 4 93 5 t3 100 1 9S 6 Standard Reference Material #1579, U.S. National Bureau of Standards. 2/15/84 7082-3 BpG40076 LEAD ICTHOO: 7OR? Additional collection efficiency studies tre also done using Gelman GN-4 filters for the collection of Pb fune, tfiich had geometric mean diameter of 0.1 ve [3]. Mean collection efficiency for 24 sampling runs at flow rates between 0.15 and 4.0 L/min was >97 21. Overall precision, sr, was 0.072 for lead nitrate aerosol [2,7] and 0.068 for Pb fune [3,9]. REFERENCES: [1] Criteria for a Recaimended Standard...Occupational Exposure to Inorganic Lead (Revised Criteria), U.S. Department of Health, Education, and Welfare, Publ. (NI0SH) 78-158 (1978). [2] Docunentation of the NI0SH Validation Tests. U.S. Department of Health, Education, and Welfare, Publ. (NI0SH) 77-185 (1977). [3] Heavy Metal Aerosols: Collection and Dissolution Efficiencies, Final Report of NI0SH Contract 210-79-0058, W. F. Gutknecht, M. H. Ranade, P. M. Grohse, A. Oamle, and 0. O'Neal, Research Triangle Institute; available as Order No. PB 83-106740 from NTIS, Springfield. VA 22161 (1981). [4] NI0SH Manual of Analytical Methods, 2nd. ed., V. 1, P6CAM 102, U.S. Department of Health, Education, and Welfare. Publ. (NIOSH) 77-157-A (1977). [5] Ibid, PACAM 191. [6] Ibid, P4CAM 214. [7] Ibid., V. 3, S341, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 77-157-C (1977). [81 Ibid, V. 5, P4CAM 173, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 77-157-A (1979). [9] Ibid, V. 7, S341 (revised 3/2S/81), U.S. Department of Health and Hunan Services, Publ. (NIOSH) 82-100 (1982). [10] Analytical Methods for Atomic Absorption Spectrophotometry, Perkin-Elmer (1976). HETHOO REVISED BY: Mark Millson and R. DeLon Hull, NIOSH/OPSE; S341 originally validated under NIOSH Contract C0C-94-74-4S; additional studies under NIOSH Contract 210-79-0058. 2/15/84 7082-4 cn cc V-*; 7. cO: BFG40077 5. Hydrochloric Acid NIOSH - 7903 BpG40078 INORGANIC AC I OS Methods Research Branch Analytical Method Analyte: Matrix: Procedure: Inorganic acids (Table I) Air Silica gel tube collection, eluent desorption, ion chromatography Method No.: Range: Precision: P&CAM 339 Table I 0.06-0.10 Date Issued: 8/18/81 Date Revised: Classification: 0 (Operational) 1. Synopsis 1.1 A known volume of air is drawn through a silica gel sampling tube to collect the analyte. The samples are desorbed in an aqueous solution of 0.003 M NaHC03/0.0024 M Na?^ with heat. Solutions of samples and standards are analyzed by means of an ion chromatograph. 2. Working Range, Sensitivity, and Detection Limit 2.1 For H3PO4, H0SO4, HNO3, and HBr, the working range is based on a 48-1 air sample and on a 15-L air sample for HC1. Refer to Table I. 2.2 The sensitivity is expressed as u9 per sample per mm chart deflection at a conductance setting of 10 pithos full scale. 2.3 With a 10-mL final solution volume and the instrumental parameters stated in the method, the lowest analytically quantifiable level (LAQL) is stated as unsample at 10% relative standard deviation. This lower limit may be extended through use of a more sensitive conductivity meter setting. 339-1 C/T a? a K- GD BFG40079 3. Interferences 3.1 Possible interferences in the method are SO2 for H2SO4 and NO2 for HNO3. collection potential on silica gel and reduction during desorption have not been investigated. 3.2 Chlorine or hypochlorite ion may interfere with chloride up to 50% of its initial concentration, and bromine may give an interference of approximately 30% of its original concentration as determined from spiked samples. The collection potential of these substances on silica gel has not been investigated. 4. Precision and Accuracy 4.1 The precision is expressed as percent relative standard deviation for the overall sampling and analytical method over the range stated for each acid (Table I). 4.2 The collection efficiencies for each of the acids are based on samples at three concentration levels, 0.2, 1 and 2 times the OSHA permissible exposure limits. 5. Advantages and Disadvantages 5.1 The advantage of ion chromatography oyer other methods is its capability of separating the ions such that each of the acid anions may be identified and measured in a single sample. 5.2 The method is specific for the acid anions. Different oxidation states of the acids have different retention times, e.g., N02, NO], SO32, SO32. 5.3 The sampling device is a solid sorbent collection tube and involves no liquids. 5.4 The sampling device will collect five inorganic acids in both particulate and vaporous forms. 5.5 Because identification is based on retention time, interferences may not be easily identified. 6. Apparatus 6.1 Air Sampling Equipment 6.1.1 Personal sampling pumps capable of operation at 0.2 L/min and calibrated to an accuracy of 5% with a representat1ve sampling tube in line. 339-2 BfG40080 6.1.2 Silica gel tubes. 7-mm o.d./4.8 mm i.d. glass tubes approximately 10 cm in length packed with 400 mg of 20/40 mesh washed silica gel in the front section and 200 mg in the backup section. Polyurethane foam plugs are placed between the sorbent sections and at the end. The front section of silica gel is held in place with a 5-mm diameter plug of thick glass fiber filter. The silica gel is washed by the following procedure: Approximately a 200-mL volume of silica gel is placed in a 1-L beaker. 500-600 mL of deionized water is added slowly with stirring. When the exothermal reaction has subsided, the silica gel is heated in a 100 *C water bath for approximately 30 minutes with occassional stirring, decanted, and rinsed four to five times with deionized water. It is heated again in deionized water for 15-30 minutes, decanted, and rinsed thoroughly with deionized water. The silica gel is then dried overnight in a 100 C oven until free flowing. If a blank of the silica gel shows any impurities, the washing procedure is repeated. Approximately 90X of the resulting silica gel will be 20/40 mesh. 6.1.3 Barometer. 6.1.4 Thermometer. 6.1.5 Hygrometer. 6.1.6 Stopwatch. 6.2 Ion chromatograph with a standard or fast run anion precolumn and separator column, a standard suppressor column, and conductimetric detector (Dionex Corp., Sunnyvale, CA, or equivalent). 6.3 Strip chart recorder. 6.4 Electronic integrator or some other suitable means of determining peak height (optional). 6.5 Centrifuge tubes, 15-mL, graduated. 6.6 Micropipettes with disposable tips for preparingstandards. 6.7 Volumetric flasks, 100-mL and 25-mL or otherconvenient sizes for preparing standard solutions. 6.8 Syringes, 10-mL, polyethylene withluer tip. 339-3 BFG40081 6.9 6.10 In-line filter holders (Swinnex-type) with 25-ain membrane filters, 0.8 im pore size, or Acrodisc in-line filters. Parafilm. 6.11 ' Water bath maintained at 100 C. Reagents Whenever possible, reagents used should be ACS reagent grade or better. 7.1 Deionized, filtered water. Conductivity grade deionized water wi.th specific conductance of 10 imho/cm or less is needed for the preparation of eluents and other solutions used in the ion chromatograph. The water must be filtered before use to avoid plugging valves in the chromatograph. 7.2 Silica gel, 3/8 mesh, grade 01, thoroughly washed with deionized water (Sec. 6.1.2). 7.3 Sodium carbonate, Na2C03. 7.4 Sodium bicarbonate, NaHC03. 7.5 Potassium chloride, KC1. 7.6 Monopotassium phosphate, KH2PO4. 7.7 Potassium sulfate, K2SO4. 7.8 Sodium nitrate, NaN03. 7.9 Sodium bromide, NaBr. 7.10 Stock standard solutions (1000 pg/.mL). Dissolve salt in deionized, filtered water in a 100-mL volumetric flask, and dilute to volume with deionized, filtered water. 7.10.1 Chloride (1000 ppm Cl"). Dissolve 0.2103 g KCl/100 mL. 7.10.2 Phosphate (1000 ppm PO^). Dissolve 1.433 g KH2PO4/IOO mL. 7.10.3 Sulfate (1000 ppm SO32). Dissolve 0.1814 g K2SO4/IOO mL. 7.10.4 Nitrate (1000 ppm NO3). Dissolve 0.13707 g NaN03/100 mL. 339-4 BFG40082 7.10.5 Bromide (1000 ppm Br-). Dissolve 0.1288 g NaBr/100 mL. 7.11 Eluent (0.003 M NaHC03/0.0024 M NaoCOi). Dissolve 1.008 g NaHC03 and 1.0176 g Na2C03 in 4 L of deionized, filtered water. 8. Procedure 8.1 Cleaning of Equipment. Glassware and plasticware should be washed in detergent and thoroughly rinsed with deionized water. Acid cleaning is not recommended. 8.2 Collection and Shipping of Samples 8.2.1 Each personal sampling pump must be calibrated with a representative collection tube in line to assure accurately known sample volumes. 8.2.2 Immediately before sampling, break the ends of the collection tube to provide an opening of at least one half of the internal diameter of the tube. 8.2.3 Insert the tube in the sampling device with the glass fiber filter plug at the inlet. Place tube in a vertical position during sampling to minimize channeling through the sorbent. 8.2.4 Collect the sample at 0.2 Lpm. The air being sampled should not pass through any hose or tubing before entering the collection tube. A sample size of 48-L is recommended. 8.2.5 Record the temperature, relative humidity, and pressure of the air being sampled. If the pressure reading is not available, record the elevation. 8.2.6 After sampling, label the collection tubes appropriately and cap the ends with plastic caps. 8.2.7 With each batch of up to 10 samples submit one blank collection tube which has been subjected to the same handling except that no air has been drawn through it. 8.3 Analysis of Samples 8.3.1 Place the silica gel and glass fiber plug from the front section of the collection tube into a 15-mL graduated centrifuge tube. (The backup section is analyzed separately.) C/T W ce C/1 O & '*' 339-5 BpG40083 8.3.2 8.3.3 Add 5-6 mL of eluent solution (Section 7.7) and heat in a 100 C water bath for 10 minutes. Allow to cool and dilute to a 10-mL volume with eluent. Cover with Parafilm and shake vigorously. Pour the contents into a 10-mL plastic syringe fitted with an in-line filter and collect the filtrate in a second syringe or autosampler vial. 8.3.4 Inject 100-U- aliquots of the filtered sample into the ion chromatograph and record the sample identity and instrumental conditions. Typical operating conditions for inorganic acids are: Eluent: Flow Rate: Columns: Conductivity Meter Setting: Injection Volume: Recorder Speed: 0.003 M NaHC03/0.0024 M Na2C03 138 mL/hr (30% pump capacity) Standard Anion precolumn Standard Anion separator Standard Anion suppressor 10 pmho full scale 100 U30 cm/hr. 8.3.5 Measure and record peak height of each peak. The use of peak height is recommended over peak area for ion chromatography. 9. Calibration and Standardization 9.1 From the 1000 ug/mL acid stock solutions in Section 7.10, prepare mixed working standards in the concentrations of 0.5, 1, 2, 5, 10, 15, and 20 pg/mL in eluent solution (Section 7.7). The use of eluent eliminates the water dip in the chromatogram which occurs immediately before the elution of the chloride peak. These standards should be prepared fresh weekly and stored in polyethylene bottles. 9.2 With each set of samples analyzed, a complete calibration curve should be constructed. Plot peak height versus concentration. 10. Calculation 10.1 Read the concentration of each sample and blank from the calibration curve obtained in Section 9.2. Calculate the net concentration of each acid anion found C] * C2 - B 339-6 BFG40084 where: Ci = acid anion concentration from air sample (pg/mL) Co = total acid anion found on silica gel tube (ug/inL) 8 = acid anion concentration from blank (gg/mL). 10.2 Calculate the concentration of acid in air sample. 10.2.1 Acid concentration in mg/m3 where: F C1 0 CA V CA acid concentration in air (mg/m1) Cl anion concentration in solution (yg/mL) 0 final volume of desorbed sample (mL) V volume of air sampled (L) F factor for converting anion to acid. Acid F H3PO4 H2SO4 HNO3 HBr HC1 1.032 1.021 1.016 1.0125 1.028 10.2.2 Vapor-forming acid concentration in ppm. One gram molecular weight of a gas occupies 24.45 L at 25 C and 760 mm Hg pressure CB * K x CA x 760 x T 298 x P where: Cg = acid concentration in air (ppm) Ca = acid concentration in air (mg/m1) T * absolute temperature at which the sample was taken (K * C 273) P = air pressure at which the sample was taken (mm Hg). K = vo1. acid g-mol. wt. acid Acid K HNO3 HBr HC1 0.3881 0.3022 0.6699 Cfl 02 cn 0 >* 339-7 BFG40085 11.1 Cassinelli, M. E. and Taylor, D. G., Monitoring for Airborne Inorganic Acids, Symposium on Measurement and Control of Chemical Hazards in the Workplace Environment, ACS Symposium Series (1980). 11.2 Cassinelli, M. E., Ion Chromatographic Determination of Hydrogen Chloride - Hydrogen Bromide Mixtures, IMDS, MRB, Technical Report (1979). Mary Ellen Cassinelli Inorganic Methods Development Section 339-8 BFG40086 Appendix D Calibration Sampling Equipment BFG40087 APPENDIX D Calibration of Sampling Equipment (OSHA Procedure (8), Industrial Hygiene OSHA Technical Manual, 1990) 1. Procedures for Calibration of Pump-Collector Tube System ( Organic Vapor Collection ) -Using Electronic Bubble Meter Method: (1) Allow the pump to run S minutes prior to voltage check and calibration. (2) Assemble the charcoal tube holder, using the appropriate tube for the sampling method. Compress charcoal tube by using a mechanical press or other means of applying pressure. Use shrink tape around charcoal tube to cover joints and prevent leakage. If a tube adaptor is using , care should be taken to ensure that it does not come in contact with the back-up pad. NOTE : When calibrating with a bubble meter , the use of tube adaptors can cause moderate to severe pressure drop at high flow rates in the sampling train, which will affect the calibration result. If adaptors are used for sampling , then they should be used when calibrating. CAUTION: Nylon adapters can restrict air flow due to plugging over time.Stainlesssteel adapters are preferred. (3) Connect the collection device, tubing, pump and calibration apparatus as shown in Figure 1 and 2 charcoal tube and cyclone samplers, respectively. 1 BFG40088 (4) A visual inspection should be made of all Tygon tubing connections. (5) Wet the inside of the electronic flow cell with the supplied soap solution by pushing on the button several times. (6) Turn on the pump and adjust the pump rotameter, if available, to the appropriate flow rate setting. (7) Press the button on the electronic bubble meter. Visually capture a single bubble and electronically time the bubble . The accompanying printer will automatically record the calibration reading in liters per minute. (8) Repeat step 7 until two reading are within 5% . (9) Repeat the procedures described above for all pumps to be used for sampling. The same charcoal tube may be used for all calibrations involving the same sampling methods. Procedure for Calibration of Pump-Cassette Filter System (Particulate - total dust). -Using Electronic Bubble Meter Method: (1) Allow the pump to run 5 minutes prior to voltage check and calibration. (2) Assemble the polystyrene cassette filter holder, using the appropriate filter for the sampling method. Compress cassette by using a mechanical press or other means of applying pressure. Use shrink tape around cassette to cover joints and prevent leakage. If a cassette adaptor is using, care should be taken to ensure that it does not come 2 in contact with the back-up pad. NOTE : When calibrating with a bubble meter , the use of cassette adaptors can cause moderate to severe pressure drop at high flow rates in the sampling train, which will affect the calibration result. If adaptors are used for sampling , then they should be used when calibrating. CAUTION: Nylon adapters can restrict air flow due to plugging over time. Stainless steel adapters are preferred. (3) Connect the collection device, tubing, pump and calibration apparatus as shown in Figure 1 and 2 cassette and cyclone samplers, respectively. (4) A visual inspection should be made of all Tygon tubing connection? (5) Wet the inside of the electronic flow cell with the supplied soup solution by pushing on the button several times. (6) Turn on the pump and adjust the pump rotameter, if available, to the appropriate flow rate setting. (7) Press the button on the electronic'bubble meter. Visually capture a single bubble and electronically time the bubble . The accompanying printer will automatically record the calibration reading in liters per minute. (8) Repeat step 7 until two reading are within 5% . (9) Repeat the procedures described above for all pumps to be used for sampling. The same cassette and filter may be used for all calibrations involving the same sampling methods. 3 BFG40090