Document 99v12ppdgD6jmmDbqy1aMYQo7
BESTWALL
HUMMER SYSTEM
"A" MODIFIED
AN IMPROVED METHOD OF APPLYING TWO LAYERS OF GYPSUM WALLBOARD TO FRAME CONSTRUCTION
See your nearest Bestwall Gypsum Dealer. Ask your Bestwall Certain-teed Salesman.
MANUFACTURED BY BESTWALL GYPSUM COMPANY
IN G fOD UC'S
Sold through: Bestwoll Certain-teed Sales Corporation 120 East Lancaster Avenue, Ardmore, Pa.
Form No. 5535
PLAINTIFFS EXHIBIT
(ol&ti H
SGP 0027208
i.
MATERIALS REQUIRED:
1. 3/8" Tapered Edge Bestwall Gypsum Wallboard.
a. For back up board use 3/8" "Backer" a 4' wide or 2* wide gray face and back paper board, or recut and scrap pieces, 3/8M thick. Where ceiling supports are 24" on center use a l/2M thick board for the back layer.
2. 3/8M Tapered Edge Bestwall Gypsum Wallboard with Center Taper paralleling long edges of board.
3. GWB-54 gypsum wallboard nails or Bestwall Hummer annular ring steel wire nail, 13-1/2 gauge, 1--3/8'* long, 15/64" flat head medium diamond point nails.
4. 4-d, 13-1/2 gauge, 1-3/8" long, l/4" flat head diamond point nail.
5. 3/4" Phillips flat head #14 wood screw threaded up to shoulders as manufactured by American Screw Company or equal.
6. 6-d double head scaffold nails.
7. Bestwall Adhesive or Casco #202.
8. Bestwall Joint System materials including Cement, Bedding Compound, Topping Compound, and Paper Tape.
APPLICATION:
The first or back layer of both walls and ceilings, with the ceilings being applied first, shall be erected and nailed to the framing members as in single layer nail-on application to wood framing according to ASA 97 except the nail heads shall not be dimpled.
Bestwall Tapered Edge Board with a Center Taper shall be used for the second or face layer on ceilings. The face layer shall be applied on the ceiling at right angles to the framing members and in such a way as to eliminate, or keep to a minimum, butt end joints. Neither the end joints or the edge joints in the face layer should fall over joints in the back layer. No edge joint nor end joint in the face layer shall fall over a nailing member. End joints shall be so installed as to fall mid way between adjacent nailing members.
Apply Bestwall Adhesive to the backside of the face layer and nail the face layer in place using 6 d double headed scaffold nails at each nailing member, with the nails confined to the Center Taper or to the Edge Taper. As the sheets are installed and before the glue has set, drivePhillips head wood screws between nailing members, in the center taper, and in the tapered edge joint between two adjacent sheets. Use a special counter sink to make a hole for screw head and to start the screw. I'he screws should then be brought up and home with sufficient force and with the board so held that the screw head will be slightly countersunk and home tight when finished. Use a screw driver with an adjustable gauge for setting screws and holding face board tight to back board. Where a butt joint occurs in the field, Phillips head wood screws 12" on center shall be driven in the joint between the two ends just as along the Tapered Edges. For best results where mill cut ends are damaged about 1" should be cut off the mill end of every board before it is in stalled where it will be at a joint in the wall or ceiling expanse (not at corners).
SGP 0027209
2
/ REQUIRED TOOLS TOR THE APPLICATION OF BBSTWALL - HUMMER SYSTEM "A," hAO~PlF 1E.T3 _
r^r~:
0- counter sink FOR. SCREWS.
0-- REMOVABLE FIN.
TWO ALLEN SCREWS
(3)- NO. 14- W TYPE "A" PHILLIPS FLAT HEAR SCREWS
AS MANUFACTURER BY AMERICAN SCREW CO.ORBOUAL.
0-SCREW RRIVER WITH AtHIOSTARUE GAUGE FOR SETTING SCReVUS ( YANKEE 313-3 PT/iSIA').
6-1S-57
After the glue has set (approximately 24 hours, at least over night) the double headed nails shall be removed. This method will leave no face layer fastener embedded in the wood nailing members or framing since the double headed nails are pulled before the joint work is started.
SIDEWALLS:
Regular Tapered Edge board shall be used on walls. The face layer shall always be applied hori zontally with the top sheet put in place first. Use Bestwall Adhesive applied to the back of the face layer. The top board is held tight against the back board while 6 d double headed nails are driven through both layers of board and into the nailing members. These nails shall be about two inches from the ceiling angle. Another row of double headed nails is driven in the tapered edge of the lower edge of the board. The next layer of board is applied with a row of double headed nails in the tapered edge on the top side. If the lower edge of the board falls under the base board, it is nailed with regular wallboard nails. If exposed, it shall be fastened with double headed nails. After the lower face layer is installed with end joints (if they occur) staggered,Phillips head wood screws should be applied in the tapered edge joints, between nailing members. End joints between sheets should fall midway between the nailing members and Phillips head wood screws should be driven in the joint 12" on center.
Where poor alignment of framing or nailing members holds the face layer from full contact with the base layer, double headed nails may be driven in the field of the board into the nailing mem bers to hold face layer against back layer till glue sets.
After glue has set (approximately 24 hours or at least over night) all double headed scaffold nails shall be removed before joint system and tape is applied. Holes in the wallboard left by the nails not under a tape shall be slightly indented and subsequently filled with joint cement. The joints shall be finished in the standard way with joint cement and tape.
The decoration of the board shall be done in the manner used on a regular gypsum wallboard in stallation. For best results a skim coat of joint system cement should be used over the entire board area as the final application before priming for decoration. In applying the skim coat the joint system cement should be mixed to a thin consistency and applied to the entire board surface with a 12" wide knife or with a wide roller, and then sheared down tightly with the wide knife. With skill this application properly made, not only can eliminate sanding, but also will tend to equalize suction over the entire board area, reduce or eliminate slight shrinkage differences that may occur if a shear coat is not applied, and level off slight imperfections that may be present that are seldom noticed in the board's surface until after it has been decorated.
ADVANTAGES & COST COMPARISON:
SGP 0027210
This method of installation does two things of great importance in wallboard installation. It eliminates any fastening device, screw or nail which is in the exposed face layer from contact
3
-r
with or penetration into any wood member. By eliminating the basic cause of nail popping (fastener v in wood) this one feature practically eliminates all possibility of this serious complaint. Insofar as the photographing of screw heads is concerned, which is a discoloration due to a temperature differential across the surface, any installation which will be such quality that the contractor and owner will pay for laminated wall construction, will invariably include building insulation in the joist and stud spaces. This insulation will eliminate the temperature differential between the screw head and the surrounding surface with the result that there is not spotting over those screw heads. The joint treatment putting all of the screw heads under a paper tape and cement is an added protection against "popping" or "spotting" of screw heads. Cutting off a minimum of 1" from the manufactured end of the wallboard sheets meeting in the field of the wall or ceiling in sures hard ends without paper split. This act with the lamination of the face layer to the back layer eliminates the major factors which contribute to beading or ridging at joints.
A Bestwall Hummer System "A" Modified installation is the best possible one to produce a
pleasing, trouble free, surface. Compared with a conventional two layer application as the Best-
wall Hummer System "A" the additional cost is minor. Based on a house 24' x 36' the additional
cost for the ceiling is:
Unit Cost Total Cost
600 - #14-3/4" Phillips Screws
$ .75
$4.50
Labor Cost 600 screws (400 per hour) 1-1/2 hrs. 3.00
4.50
Drawing double headed nail 1 hour Center tape board
3.00 0.001
3.00 0.85
$12.85
Labor cost to tape center taper is about the same as filling two rows of nails.
The same house might have 300 lineal feet of wall 8' high. The additional cost would be:
150 #14-3/4" Phillips Screws Labor cost 150 screws (400 per hour) 1/2 hour Drawing double headed nails 1/2 hours
Extra for walls and ceilings Less labor filling nails in center of bd. 3 hours
$ .75 3.00 3.00
3.00
$1.25 1.50 1.50
9.00
4.25 17.10
9.00
v/jrr)
Total extra for a small house
$8.10
With savings by improved techniques and eliminating going back to repair pops or joint beads, Bestwall Hummer System "A" Modified may actually be cheaper than conventional two layer ap plications. In comparison with the method requiring glue and back up of all joints with special bracing in erection, there is little difference in cost in place, yet the finished wall is a complete double layer and definitely a better quality job.
A variation that may reduce the cost, but at the same time sacrifices some of the advantages of the overall scheme is to use a regular gypsum wallboard nail 1-5/8" long in the finished layer in nailing the face layer up before using screws, instead of a double headed nail. Using this nail only in the Taper (Edge or Center) and leaving it in place, will still leave all nails and screws covered by a paper tape and cement. Nails in the taper at the joint should be placed so as to al ways fall under the paper tape. This variation will help reduce nail "popping" and "spotting" but is not as positive as the method of pulling the nails.
Using this alternate reduces the number of Phillips head screws and eliminates the double headed nails in the ceiling so that the extra cost shown above is only:
300 - #14-3/4" Phillips screws (ceilings) Labor cost 300 screws 1-3/4 hours Drawing double head nails 1 hour
$ .75 3.00 3.00
$2.25 2.25 3.00
$7.50
Thus the cost of this alternate is practically the same as conventional two layer work.
The following sheets give the specifications in detail 4
SGP 0027211
/
o 6.
a* $ 0IK.
35 >
LJ rlO
0
i 4
pi
16
z 2 ev> Si $5
2 * lA
II5 !j U-* 4
*8 ^0 o
*?
p z5
(9 2
5?
-o <( *>
&
mun
* ;* a is Z
t
ui &z cuci
g
o (8 wu
u-
x
iX-
t
5
sy<//>
g
4o
to
<5 Z
yoo i/)
suyi 4
uUi V<f-f J
G o->
.iff
o
IS z
Df LU
0>
X
111
ui o
u0
@(2
SGP 00272^2
5
6 SGP 0027213
r
i a
<a
7
6 -1 6 -S 7
* v> O
2
5
ul <j
SI 2
53
jh o. *>
p
So|uo0I.
fUtI
i
a
gkv u!
w 1o0o < XUI sIk
?
o o3 U>V*XU1)I 2 3JOm
$
< 2 w<ulo*-
g 3j az 8U/>I
J4 *o 8ul?L U-JI Mo.f g. 2*
ZUM*I uUI KZ o-> -tu ir<-n
@
I
U ui
2 2
P
D <-
i -I Ul
<h
?
</> >
& if)
Ml
O
z
_1
ui
O
m-
j
.j <
8
** e<<a* 10
o
$ 9
BESTWALL GYPSUM
BUILDING PRODUCTS
GYPSUM LATH AND PLASTER LIME
FIRESTOP BESTWALL GYPSUM WALLBOARD GYPSUM WALLBOARD GYPSUM SHEATHING GYPSUM ROOF DECKS JOINT SYSTEM BEDDING COMPOUND TOPPING COMPOUND CERTEX TEXTURE JOINT TAPE
SPACKLING COMPOUND PATCHING PLASTER
For further information and details:
BESTWALL CERTAIN-TEED SALES CORPORATION 120 East Lancaster Ave. Ardmore, Pennsylvania
;
ATLANTA 3, GEORGIA 1010 Rhodes Haverty Building
134 Peachtree Street
CHICAGO 4, ILLINOIS 208 So. LaSalle Street
CHICAGO HEIGHTS, ILLINOIS P. O. Box 302
10th & State Streets
CLEVELAND 14, OHIO 815 Superior Avenue
DALLAS 22, TEXAS P. O. Box 6030
DES MOINES 9, IOWA 505 Fifth Avenue
DISTRICT SALES OFFICES
DETROIT 4, MICHIGAN 305 Woodbrook Bldg. 5050 Joy Road
EAST ST. LOUIS, ILLINOIS 17th Street L Broadway
JACKSON 6, MISSISSIPPI P. O. Box 4615 Fondren Station
KANSAS CITY 26, MISSOURI 1248 Crystal Street
MINNEAPOLIS 2, MINNESOTA 210 Frontenac Bldg.
509 Second Ave., South
BUFFALO 26, NEW YORK P.O. Box 2608
Amherst Branch
RICHMOND 4, CALIFORNIA 1014 Chesley Avenue
SALT LAKE CITY 1, UTAH 119 West 2nd, South
TACOMA 2, WASHINGTON 1718 Thorne Road
WILMINGTON 3, DELAWARE 2011 Concord Pike
EXPORT OFFICE: 100 East 42nd Street, New York 17, New York
SGP 0027217
Printed in U.S.A.
4-
BESTWALL
HUMMER SYSTEM STRIP LAMINATION
) DESIGNED TO PREVENT JOINT BEADING Stops edge movement DELAYED SHRINKAGE By eliniinating high edges with strip lamination and screws NAIL POPS With all nails and fastenings under tapes and trim
See your nearest Bestwall Gypsum Dealer.
Ask your Bestwall Certain-teed Salesman.
IMJII MANUFACTURED BY BESTWALL GYPSUM COMPANY
*t'U<NC
fOOUc1S
Sold through: Bestwall Certain-teed Sales Corporation 120 East Lancaster Avenue, Ardmore, Pa.
Form No. 5537
SGP 0027218
* * k
MATERIALS REQUIRED:
1. *4" Tapered Edge Bestwall Gypsum Wallboard. 2. Strips of %" by 8" wide Bestwall Gypsum Wallboard. 3. 14" Tapered Edge Bestwall Gypsum Wallboard with Center Taper paralleling long edges of board. 4. Bestwall Hummer annular ring steel wire nail, 13 gauge, 1%" long, 15/64" flat head medium diamond point
nails. 5. Blued plaster board nail, 114" long or longer. 6. %" Phillips flat head #14 wood screw threaded up to shoulders as manufactured by American Screw Com
pany (Chicago), or equal. 7. 6-d double headed nails (Scaffold type nails). 8. Bestwall Joint System Cement or Bestwall Joint System Bedding Compound and Topping Compound,
Paper Tape, and Bestwall Joint System Laminating Compound.
APPLICATION: The plans for the building should be studied and a layout of 4' wide by 8' to 16' long board should be made with the board at right angles to the framing and the length of the board such as to reduce or eliminate end joints in the field of walls or ceilings. Where an end joint must be made in the field area of either wall or ceil ing it should be made to fall midway between adjacent framing members (joists, rafters, or studs).
STRIPS: 8" wide strips of %" gypsum wallboard spaced to fall under edge joints of the board and under the center of the wall board (maximum 2' on center) shall be applied first to the ceiling and then to the walls at right angles to the framing members. A strip shall be in both the wall and ceiling planes at the ceiling angles and at the floor in all walls. These strips may be 4" wide with 2 cut from a full 8" strip. Use two nails at each stud or joist on all strips regardless of width. Nail 1" from edge of strip and do not dimple board at nail head. A short 8" strip of %" wallboard should be nailed to the two framing members, midway between the full length 8" strips, so as to fall beneath any end joint in the face layer not in a comer.
CEILING FACE LAYER: Bestwall Tapered Edge Board with a Center Taper shall be used for the face layer on ceilings. The face
layer shall be applied on the ceiling at right angles to the framing members, and in such a way as to have edges fall on the 8" strips. No edge joint nor end joint in the face layer shall fall over a nailing member. End joints shall be so installed as to fall midway between nailing members. These end joints will be reinforced by the short 8" strip filled in when stripping the ceiling. Apply strips of Bestwall Laminating Compound to the backside of the face layer to match the strips of board in place and nail the face layer using 5-d, 1%" long, annular ring wallboard nails in the center taper and %" from edges of board. As the sheets are installed and before the glue has set, drive Phillips head wood screws between nailing members in the center taper and in the tapered edge joint between two adjacent sheets. Use a special counter sink to make a hole for screw head and to start the screw. The screws should then be brought up and home with sufficient force and with the board so held that the screw head will be slightly countersunk and home tight when finished. Use a screw driver with an adjustable gauge for setting screws and holding face
SGP 0027219
2
REQUIRED TOOLS FOR THE APPLICATION OF BBSTWALL - HUKAWER SYSTEM "A" AAO'DIFTE'D
_
TM-:
0- COUNTER SINK FOB SCREWS.
0- REMOVASCE TIN.
ATLWLOEK SCREWS
0- NO. 14 W TYPE "A" PHILLIPS FUAT HEAP SCREWS W AS MANUFACTURER RY AMERICAN SCREW CO. (CHI CAGO, ILL.) OR EQUAL.
0-SCREW PRlVER. WITH ADJUSTABLE GAUGE FOR SETTING SCREWS (YANKEE 3(3-3 PT/i3IA).
11-25-57
board tight to back board. Where a butt joint occurs in the field, Phillips head wood screws 12" on center shall be driven in the joint between the two ends just as along the tapered edges. For best results where mill cut ends are damaged about 1" should be cut off (cut face side) before it is installed where it will be at a butt joint in the wall or ceiling expanse (not at comers).
SIDEWALL FACE LAYER:
Regular tapered edge board shall be used on walls. The face layer shall always be applied horizontally with the top sheet put in place first. Use strips of Bestwall Laminating Compound applied to the back of the face layer, at edges and in center of board. Nail the face layer in place using 5-d, 1%" long annular ring nails %" from edge of board in center joint and also from ceiling line and under base or trim. After the lower face layer is installed with end joints (if they occur) staggered, Phillips head wood screws shall be applied in tapered edge joints, between nailing members. End joints between sheets should fall midway between the nailing members and Phillips head wood screws should be driven in the joint 12" on center.
Where poor alignment of framing or nailing members holds the face layer from full contact with the base layer, double headed nails may be driven in the field of the board into the nailing members to hold face layer against back layer till glue sets.
For best results the face layer boards for the side walls should be stacked face side up on the floor for 12 hours before use with %" strips 40" apart under the long (closed) edges of the board and a weight in the center. When the board is nailed up, the slight bow will bring the center area snug against the center 8" strip and be held by the nails at the top and bottom of the sheet. This will help eliminate nails from center area of board. After glue has set (approximately 24 hours or at least over night) all double headed nails used shall be removed before joint system and tape is applied. Holes in the wallboard left by the nails not under a tape shall be slightly indented and subsequently filled with joint cement. The joints shall be finished in the standard way with joint cement and tape.
The decoration of the board shall be done in the manner used on a regular gypsum wallboard installation. For best results a skim coat of joint system cement should be used over the entire board area as the final applica tion before priming for decoration. In applying the skim coat, the joint system cement should be mixed to a thin consistency and applied to the entire board surface with a 12" wide knife or with a wide roller, and then sheared down tightly with the wide knife. With skill this application properly made not only can eliminate sanding, but also will tend to equalize suction over the entire board area, reduce or eliminate slight shrinkage differences that may occur if a shear coat is not applied, and level off slight imperfections that may be present that are seldom noticed in the board's surface until after it has been decorated.
SGP 0027220
ADVANTAGES & COST COMPARISON:
This method of installation does two things of great importance in wallboard installation. It eliminates any fastening device, screw or nail which is in the exposed face layer from contact with or penetration into any wood members which are not under joint system and tape. By eliminating the basic cause of nail popping (fastener in wood not under joint system and tape) this one feature practically eliminates all possi bility of this serious complaint. Insofar as the photographing of screw or nail heads is concerned, which is a discoloration due to a tempearture differential across the surface, a quality construction including laminated wall construction will invariably include building insulation in the joist and stud spaces. This insulation will reduce or eliminate the temperature differential between the screw or nail head and the surrounding surface with the result that there is no spotting over these areas. The joint treatment putting all of the screw and nail heads under a paper tape and cement is an added protection against "popping" or "spotting" of the heads. Cutting off a minimum of 1" from the manufactured end of the wallboard sheets meeting in the field of the wall or ceiling insures hard ends without paper split. This act with the lamination of the face layer to the back strips eliminates the major factors which contribute to beading or ridging at joints.
A Bestwall Hummer System strip laminated installation will produce a pleasing, trouble free, surface. Com pared with a conventional gypsum wallboard application, the additional cost is minor. Based on a house 24' x 36' (average 5% rooms), the additional cost is:
FOR CEILINGS:
Unit Cost Total Cost
"BOWED BOARD PULLED INTO PLACE TOP $ BOTTOM BY NAILS
I*
450 lineal ft., 8" wide strips (including 4" strips at
ceiling edge) --300 sq. ft.
--
Labor for stripping -- 3 hrs.
$3.00
800 sq. ft. center tape board (extra cost)
0.002
Laminating Compound -- 5#
0.20
Labor applying Laminating Componnd -- 1 hr. 3.00
350--#14 %" Phillips Screws
1.25
Labor Cost 350 screws (400 per hr.) -- 1 hr.
3.00
FOR WALLS:
$15.00 9.00 1.60 1.00 3.00 4.40 3.00
$36.90
1260 lineal ft., 8" wide strips (including 4" strips at
ceiling and floor) -- 840 sq. ft.
--
$42.00
Labor for stripping--5 hrs.
$3.00
15.00
Laminating Compound --15#
0.20 3.00
Labor applying Laminating Compound -- 2 hrs. 3.00
6.00
150, #14 %" Phillips Screws
Labor Cost 15Q Screws (400 per hr.) -- y2 hr.
1.25 3.00
1.90 1.50
CD TOTAL F.OR HOUSE
$69.40 $106.30
BOWED "BOARD IN CONTACT WITH
CENTER STRIP
With savings by improved techniques and eliminating going back to repair "pops" or joint "beads", Bestwall Hummer System Strip Lamination is cheaper than a conven tional two layer Application. In comparison with the method requiring glue and back up of all joints with special bracing in erection, there is little difference in cost in
place, yet the finished wall closely matches a complete double layer installation.
The following sheets give the specifications in detail.
SGP 0027221
E0 1
00
NAILING BOWED BOARD ON WALLS
BOWING FACE BOARD FOR. WALLS
T7 FLOOR LINE
-J
STACK FACE SIDE UP 12 HOURS BEFORE USING
Ul
>~ CO M QL i Ul
Ii
rh .<
o
a
<
W) 2
h V> O
g />
<
">
zo
5
< UJ
o a.
o </> <
(30 "
Ul 0 Lu
(J P
3
vA Cl
-I
Ja *M
Ul V 2*
(A O
cC
o oo St!
Kz
W s^? o 'I1
< CD U
SGP 0027222
i
00 7)
UJ
vD 0
UJ
1w
0
Vi P-
u.
1 efL
s v>
I
< Z
V) D
ooz
ft
tU o>
o of<t tfl
o6
in h Z o ~)
CO _l
-J
<
$
<z 0a
UJ 0 $ co
y M<-
Z
<.
--
3
ian.
>
aui tn <
* o-
_ 0O p
/ OD
P3 . X
UJ
3_i
in ^ co
fc 1
1 fO
2
O
VaI ha
V)
p
%
%
la3/l >0
00
1
UJ
vn
s
D
UJ
V)
O O-
X UJ
SGP 0027223
SGP 0027224
7
BESTWALL GYPSUM
BUILDING PRODUCTS
GYPSUM LATH AND PLASTER LIME
FIRESTOP BESTWALL GYPSUM WALLBOARD GYPSUM WALLBOARD GYPSUM SHEATHING GYPSUM ROOF DECKS JOINT SYSTEM BEDDING COMPOUND TOPPING COMPOUND CERTEX TEXTURE JOINT TAPE
SPACKLING COMPOUND PATCHING PLASTER
For further information and details:
BESTWALL CERTAIN-TEED SALES CORPORATION 120 East Lancaster Ave. Ardmore, Pennsylvania
ATLANTA 3, GEORGIA 1010 Rhodes Haverty Building
134 Peachtree Street
BUFFALO 26, NEW YORK P.O. Box 2608
Amherst Branch
CHICAGO 4, ILLINOIS 208 So. LaSalle Street
CHICAGO HEIGHTS, ILLINOIS P. O. Box 302
10th & State Streets
CLEVELAND 14, OHIO 815 Superior Avenue
DISTRICT SALES OFFICES
DES MOINES 9, IOWA 505 Fifth Avenue
DETROIT 4, MICHIGAN 305 Woodbrook Bldg. 5050 Joy Road
EAST ST. LOUIS, ILLINOIS 17th Street & Broadway
JACKSON 6, MISSISSIPPI P. O. Box 4615 Fondren Station
MINNEAPOLIS 2, MINNESOTA 210 Frontenac Bldg.
509 Second Ave., South
RICHMOND 4, CALIFORNIA 1014 Chesley A\enue
SALT LAKE CITY 1, UTAH 119 West 2nd, South
TACOMA 2, WASHINGTON 1718 Thorne Road
DALLAS 22, TEXAS P. O. Box 6030
KANSAS CITY 26, MISSOURI 1248 Crystal Street
WILMINGTON 3, DELAWARE 2011 Concord Pike
EXPORT OFFICE: 100 East 42nd Street, New York 17, New York
______
SGP 0027225
5M-4-58
Printed in U.S.A.
BESTWALL
HUMMER SYSTEM
"B" MODI FI KD
A NON LOAD BEARING THIN GYPSUM WALLBOARD PARTITION
LOW COST SPEEDY CONSTRUCTION FIRE RESISTANCE 1, 2 OR 3 HOURS
See your nearest Bestwall Gypsum Dealer. Ask your Bestwall Certain-teed Salesman.
I
4`-
Htpoo^Gr^su*,
*U,,0/N G pROOV)1-15
MANUFACTURED BY BESTWALL GYPSUM COMPANY
Ardmore, Pa.
i.1 i ``H#1
SGP 0027226
MATERIALS REQUIRED:
1. %" Firestop Bestwall Tapered Edge Gypsum Wallboard.
2. Gypsum Wallboard Studs laminated in plant (or on job).
(a) 2 layers y2" (or %", or %") thick, 3y2" x 8'.
(b) 2 layers y2" (or
or %") thick, 6%" x 8'.
3. 1", IW, and 2" Phillips flat head #14 wood screws, (as manufactured by American Screw Company, Chicago, 111., or equal.)
4. Nails, Rawl type drives, screws, etc., as shown in details.
5. Bestwall Joint System Materials including Cement, Bedding Compound, Topping Compound, Tape, Lami nating Compound and Certex Texture.
6. Metal and/or wood: door frames, runners, trim, caps, etc., as per architectural details (similar to those shown in Bestwall Hummer System "B" Modified Booklet.)
APPLICATION:
GENERAL NOTES
The plans for the building should be studied and a layout made to determine corner and wall intersections, door openings, location of conduits within the wall, necessary temporary bracing, and the order of installation. With experience and care the work can be expedited and the loss due to cut pieces necessary to make inter sections shown by the architectural plans reduced to a minimum.
The actual layout of the partitions, installation of floor and ceiling runners, setting of door frames, hanging doors, trimming (including openings, floor and ceiling) mentioned in the following specifications and shown on the detail sheets are generally included in new construction, in the carpentry sub-contract. Decoration mentioned in the concluding section is generally included in the painting sub-contract. Any contract based on the following specifications should clearly stipulate the responsibility of the wallboard or partition contract. A contract for partitions only, in existing buildings, may cover all the work in one agreement.
CEILINGS
Ceiling installations aren't covered under the Bestwall Hummer System "B" Modified Specifications since these are for walls and partitions only. Where ceilings are to be installed, it is suggested that to correspond with the economies possible with "B" Modified, a Bestwall Hummer Strip Lamination gypsum wallboard in stallation be made. Where acoustical treatment or other installation is desired, the owner and architect should make the specifications for the particular installation required.
OLD WORK
The "B" Modified System partition may be used in an existing building regardless of the ceilings, whether they are plastered, wallboard, concrete or acoustical treatment or the construction of the walls. Suggested details following this specification show how to treat different conditions.
PANEL ASSEMBLY
Assemble one half of the laminated wall panel as shown on page 4.`-Use three 2" x 4"s as a base for the assembly with a V6" crown (do not exceed *4"). See details page 4. Use this same type base to stack %" Firestop board for other side of panels.
Mix Bestwall Laminating Compound to a consistency that the combed ridges will not self level when the board is in a vertical position (approximately 2% pounds per 1 gallon of water). Apply the laminating compound to three sets of ribs (a set is 3 ribs, 6 Vi", 3y2" and 6Vi" wide) with a 12" spreader as shown on page 4 (one side only at this time).
Place the ribs as shown building a stack about 4 feet in height using the gauge blocks to space ribs each time. A 3" strip of the laminating compound should be scraped off the 6Vi" rib that in place, extends over the board 2%". Weigh down the stack of panels with several bundles of board and leave set for at least 12 hours before using.
SGP 0027227
1
Do not leave a stack or a panel more than 10 minutes without weighting it down. Do not take panels from stack until they are placed in wall.
INTERIOR PARTITIONS
Lay out the partitions on the floor and install floor runner. Where there is a wood sub-floor, the runner may be nailed in place with a 10D nail. If there is a concrete floor, the wood runner should be predrilled and con crete nails used or screws with plugs or shields set in the floor. The fasteners should be every two feet. Where the partition extends to the ceiling and is to be fastened, the top runner shall be plumbed up over the floor runner and fastened in place. (For metal runners use short concrete nails in flanges on floor.)
Where metal door frames are used they shall be set in place and braced. Other type doors shall be located and all openings noted.
Begin erection at starting point, whether it is an outer wall, a column or a corridor intersection as determined from an over-all study of the floor plans.
NOTE: Where the ceiling is being installed at the same time as the walls as in new construction, nailers shall be provided over the partition if it is not at right angles to framing in the ceiling nor directly under a framing member. These nailers shall be 2" x 4"s, 24" on center and fastened firmly to framing with face in plane of framing.
ERECTING FIRST HALF PANEL
Apply Bestwall Laminating Compound with the comb spreader (box type shown on page 11) to the 3Y4" lap joint before placing panel in the wall. Nail panel to the top and bottom runners with 1%" Bestwall Hummer Annular ring nails spaced 12" on center. Nail top of board within %" of the ceiling which will bring it under joint tape or trim. Do not dimple board for nail head at these points. With metal runners use 1" long #14 Phillips flat head wood screws 12" on center.
Reinforce joint between panels by using 1 Yi" long Phillips flat head wood screws %" from edge of board in taper, 12" from the floor and from the ceiling and spaced 24" on center between. Use countersink for screw heads and drill Yt" hole through first layer before setting screws. Draw head of screws 1/32" below surface. See details page 5.
ELECTRIC WIRING
All electric work shall be under the electrical sub-contract. Rigid conduit can be installed after the first side of the partition is in place, and run in the core space vertic ally and along the top and bottom of the panels in the space left by holding the core strips back. Where the O.D. of the conduit requires added space, 1^4" ribs (2 strips %" board) should be used. This will result in a 2Yi' thick wall and runners, door frames, and trim should be specified properly. (See page 9) The oppo site side of the panel is set in place after the rigid conduit is installed.
Flexible conduit can be installed in the completed wall from the floor or the ceiling in the 1" core space. Outlet and switch boxes (shallowtype) shall be installed as detailed on page 9. The board shall be cut clean and neatly for the box.
ERECTING SECOND (OPPOSITE) FACE BOARD
Apply strips of Bestwall Laminating Compound to back of face board with box type comb spreader where board comes in contact with laminated ribs in place. Fasten this face board in place at top and bottom in the same manner the first side was placed. Be sure to offset the edges in the second sheet so that the vertical joints in the finished wall do not fall one over the other (see page 5).
After two of the second face sheets are up, reinforce the joint and hold the boards in tight contact until the laminating compound has set by using 1 Yz" long Phillips flat head wood screws in the joint 12" from the top and the floor and spaced 24" on center between. Use a countersink for screw heads before starting screws. Draw head of screw 1/32" below surface.
FIRE RATED WALLS, 1, 2, AND 3 HOURS (NONLOAD BEARING)
The 2*4" wall described above with certain additional fastenings (closer spacing) is listed by Underwriters' Laboratories as 1 Hour Fire Resistive (see Bestwall detail plan sheet #5583 -- "Firestop Bestwall -- Gypsum Wallboard One Hour Nonload Bearing Studless Wall").
SGP 0027228
2
Adding another layer of %" board on each side of the partition with two runners and making the two sides independent results in a wall 4" thick which is listed by Underwriters' Laboratories as 2 Hour Fire Resistive (see detail plan sheet #5584 -- "Firestop Bestwall Gypsum -- 2 Hour Nonload Bearing Studless Wall").
Separating the two double layer faces by another inch making a wall 5" thick gives a wall section listed by Underwriters' Laboratories as 3 Hour Fire Resistive (see Bestwall detail plan sheet #5585 -- "Firestop Bestwall Gypsum 3 Hours Nonload Bearing Studless Wall".).
DOOR OPENINGS
Fill in core space around door and other openings in the wall with 6%" rib covered on both sides with laminating compound. Drive wood clamps in place immediately and leave for at least 12 hours. After clamps are removed, the doors and jambs (hang door and trim one side on bench) shall be set in openings and trimmed and the base and ceiling molding nailed in place. See details page 6.
If metal door frames are in sections they may be set after the walls are in place and the core space filled. Generally, however, metal door frames are a unit which must be set before the wall. In this case, the walls must be erected with one wall first and set into the frame, then a 6y4" filler set around the door, and finally the other face set. Wood shims with fast setting mastic against metal shall be inserted around the metal frame to wedge it tightly in place. Use joint cement to fill the crack completely. See details page 7.
SELF FURRING WALLS
(a) outside walls
Page 10 shows application of half of Bestwall Hummer System "B" Modified panels with ribs as a self furring wall. The only contact with the outside masonry wall is the no-drip shims nailed to the panel to pre vent any water seepage through the outside wall coming in contact with the inner wall (gypsum board panels). A small shim made of cut squares of roofing (210# uniform thick) as detailed on page 10 is used. Additional shimming may be needed to true up wall.
(b) interior walls
The same details may be used over masonry interior walls. The panels are attached at the ribs to the masonry wall with Rawl type drives or suitable fastenings. DETAILS SHOWN ON PAGES 4 THROUGH 10 INDICATE VARIATIONS FOR DIFFERENT JOB CONDITIONS. CAUTION: All nails, screws or fastenings are under tape and joint finish or trim. The boards should not be
dimpled when nailing under tapes and joint finish.
All screws should be drawn tightly so the head is about 1/32" below the face of the board.
JOINT WORK
Apply Bestwall Bedding compound or joint system cement to the taper edge joints and screw heads, shear off surplus, leaving no material on high edges. Allow to dry 12 hours before taping, leaving a uniform depth of taper for uniform shrinkage of joint finishes over and under tapes.
Apply Bestwall Bedding compound or joint system cement and bed tapes leaving a uniform thickness of material under the tapes.
When Bedding Compound or joint system cement has whitened (surface dry or dry) cover taped joint with Bestwall Topping Compound. Shear off surplus, leaving a uniform coverage over tapes with edges well feathered.
The Bedding Compound or joint system cement under the tapes and first coverage of tapes with Topping Compound must be thoroughly dry before the next (2nd) coverage of the joint.
Cover joints a second time with Topping Compound, shear off surplus, leaving a smooth, well feathered joint. For bekt results and a more uniform suction over entire area, apply a skim coat over the surface of the board and joints and shear off tight in lieu of second application of topping.
DECORATION
Where a skim coat has been used to finish the wall board, a one coat paint application may be satisfactory. For best results use a prime coat over wallboard area before final decoration.
SGP 0027229
3
80 :=o ~S Q
in Q c
_o
52 r/) -O 9
O |S-O
^ Ml
5
az
3 O & uO
Oz
< in Z2
i"
<o o o
p<
u 3a.
CL
< SGP 0027230
4
SGP 0027231
5
0> 0=0) to U D to
CO 8*3
I |> 2fl) s * TAaJ O>-"Ea> .
> cCCj -^'J Sjo;x"0t
HUl 5O)f^i0<-3 Jk.j O.S4
tj 2 O
Zo
Os. O
r>
.Q
o
|=
.9 S
8
*
|:i
o "
Zo
<j _C_
<; o) o .E0> 5
|II6 * *
0">- *Q. Q2- *c.
j? o o "
--"u_ _E0i 7o^
<r9.5 I ,.?s
Qs.
<
u. U
<hui
o2Q
O ooQ
ac
So
*
d. a. 3O
.. 1 z ..s ' 51?
V -
-- ff G> *5=
r 5> a T'Tr ,H;
-- l' /
1
oz
>0 zt0
oQ. tooat
zQ.
e
--a
-0--D--Q-
wc
op u<
OQ52 cQ*.
2*-0----o- Q.
r
<
u
SGP 0027232
6
SGP 0027233
7
D e ta il
8
HUMMER SYSTEM " B "
MODIFIED
W a ll Intersections & D etails
January, 1959
Sheet 5
A -N--
4. ft RMj
0-
N
4
-<v
-f\^NJ--
w
i Dc> I
4O
< <
ui
>
t
?5y
-o
COoO
>
SGP 0027235
9
10
TOOLS FOR THE APPLICATION OF BESTWALL-HUMMER SYSTEM "B" MODIFIED
1. Bestwall Laminating Compound spreader.
2. Bestwall Laminating Compound spreader (Box type)
3. Countersink for screws.
4. Screwdriver with gauge for Phillips flat head screws. Items 1-2-3 & 4 available from Franklin & Penny, West Chester, Penna.
5. No. 14- Phillips flat head wood screws plus bit brace (for Phillips flat head screws) and *4" Drill.
SGP 0027237
STABILITY
The Bestwall Hummer System "B" Modified in the official fire test at Underwriters' passed a standard hose stream test as described in ASTM El 19 in developing a one hour rating. This is a severe impact test in itself proving the stability of the construction and the strength of the fasteners.
Four 8' square panels of the Bestwall Hummer System "B" Modified were subjected to a 60 pound sand bag bump test as described in ASTM E72. There was no failure after 10 blows with a four foot drop of the 60# weight. When the panel was struck by the 60 pound weight Swung through 90 (4' drop), the immediate de flection at the center was 1.18 inches with a residual set of 0.05 inches. A 2" x 4" (16" on C.) wood stud
partition faced with y2" gypsum wallboard on each side in a similar test at the same time deflected 1.30 inches.
The 2 hour and 3 hour fire resistive construction with independent faces have practically no deflection or set under 10 blows of the 60 pound weight dropped 4'.
SOUND
Sound tests at Riverbank Laboratories have developed a sound transmission loss of 30 decibels with Bestwall
Hummer System "B" Modified and 40 decibels with 3 hour version including y2" Fiberglas mat in between
2 faces. (Tests made in 1957 after Riverbanks radically changed method of test).
VALUE
The method of construction including lamination, Phillips head screws, all fasteners under tape, and a tight shear coat eliminates joint beading, delayed shrinkage and nail pops.
SPACE SAVING
The Bestwall Hummer System "B" Modified being 2 (4" wide takes only y2 the space a 2" x 4" stud wall
finished on both sides with y2" gypsum board. With 100' of interior partition in a house, this would add
20 sq. ft. of usable floor space.
FIRE RESISTANCE
1 hr. -- 2 hr. -- 3 hr. Non-load Bearing Partitions (see details)
12
SGP 0027238
FIREPROOF
Gypsum
&E5TWAIL
BU'tU/NG
PRODUCT S
GYPSUM LATH AND PLASTER LIME
FIRESTOP BESTWALL GYPSUM WALLBOARD GYPSUM WALLBOARD GYPSUM SHEATHING GYPSUM ROOF DECKS JOINT SYSTEM BEDDING COMPOUND TOPPING COMPOUND
LAMINATING COMPOUND CERTEX TEXTURE JOINT TAPE
SPACKLING COMPOUND PATCHING PLASTER
BESTWALL GYPSUM COMPANY
ARDMORE, PA. Plants and District Offices in Principal Cities Throughout the United States
Form No. BW-59323 Jan. 59-10M-L
SGP 0027239
Printed in U S.A.
BESTWALL
HUMMER SYSTEM
"C"
NON LOAD BEARING INTERIOR PARTITIONS LOW COST GYPSUM WALLBOARD ASSEMBLY NO JOINT TREATMENT NO EXPOSED FASTENERS MOVABLE OR PERMANENT
See your nearest Bestwall Gypsum Dealer. Ask your Bestwall Certain-teed Salesman.
oous
MANUFACTURED BY BESTWALL GYPSUM COMPANY
Sold through: Bestwall Certain-teed Sales Corporation 120 East Lancaster Avenue, Ardmore, Pa.
SGP 0027246
MATERIALS REQUIRED: 1. 16" wide, rounded edge Bestwall Hummer "C" Panel, 8' long
or 24" wide, beveled edge Bestwall Hummer "C" Panel, 8' long. 2. %" x 1%" wood runner. (See note on rigid conduit in Electrical Section) 3. Nails, rawl drives, screws, etc., as shown.
4. iy2" Phillips flat head #14 wood screw (as manufactured by American Screw Company, Chicago, or equal).
5. Bestwall Laminating Compound, non-setting mastic, and quick setting mastic. 6. Metal and wood door frames, wood runners, cap and trim as per architectural details (similar to those
shown in details in Bestwall Hummer System "C" Booklet). 7. Metal corner and casing sections as per details indicated in plans and specifications (similar to those indi
cated in the Bestwall Hummer System "C" Booklet).
APPLICATION:
GENERAL NOTES
The plans for the building should be studied and a layout of the 16" (or 24") wide "C" panels made to deter mine corner and wall intersections, door openings, location of conduits within wall, necessary temporary bracing, and the order of installation. With experience and care the work can be expedited and the loss due to cut pieces necessary to make intersections shown by the architectural plans reduced to a minimum. The actual layout of the partitions, installation of floor and ceiling runners, setting of door frames, hanging doors, trimming (including openings, floor and ceiling) mentioned in the following specifications and shown on the detail sheets are generally included in new construction, in the carpentry sub-contract. Decoration men tioned in the concluding section is generally included in the painting sub-contract. Any contract based on the following specifications should clearly stipulate the responsibility of the wallboard or partition contract. A contract for partitions only in an existing building may cover all the work in one agreement.
CEILINGS
Ceiling installations are not covered under the Bestwall Hummer System "C" instructions since these are for partitions only. Where ceilings are to be installed, it is suggested that to correspond with the economies pos sible with the Bestwall Hummer "C" System a Bestwall Hummer "Strip Lamination" gypsum wallboard installation be made. Where acoustical treatment or other installation is desired, the owner and architect should make the specifications for the particular installation required.
OLD WORK
The "C" System partitions may be used in an existing building regardless of the type walls, whether they are plastered, wallboard, or masonry and regardless of the ceilings, whether they are plastered, wallboard concrete or acoustical treatment. Suggested details following this specification show how to treat different conditions.
INTERIOR PARTITIONS: Lay out the partitions on the floor and install floor runner. Where there is a wood sub-floor, the runner may be nailed in place with a 10D nail. If there is a concrete floor, the wood runner should be predrilled and concrete nails used or screws with plugs or shields set in the floor. The fasteners should be every two feet.
SGP 0027247
Where the partition extends to the ceiling and is to be fastened, the top runner shall be plumbed up over the floor runner and fastened in place.
Where metal door frames are used they shall be set in place and braced. Other type doors shall be located and all openings noted.
Begin erection at starting point, whether it is an outer wall, a column or a corridor intersection as determined from an over-all study of the floor plans.
MOVABLE INSTALLATION
Use the metal trim to close the edge against the wall and set the first
panel in place using a 4D flat head nail in the floor and ceiling runner.
Where there are no conduits to be installed in the wall section, the opposite face may be put in following closely with the first face. Please notice the method of staggering the joints in the board, which is nec
Grind-off to Form Standard 82 Countersink
Point
W* D*a.
Bolt
essary to develop the tongue and groove feature of the material. As
each panel of the opposite face is set in place, run ribbons of non
setting mastic down the strips of %" board on the back of the panel,
set them in place and then countersink (using Tool A) and predrill
for the Phillips Head Screws to be used in the tongue of the last panel
set. These screws should be placed 2' from the floor and the ceiling
and then approximately 2' on center through the rest of the length
from floor to ceiling. In driving the Phillips head screws home, the panels on opposite sides shall be held
firmly in place so that the screw can be drawn up tight without stripping. The panels will have to be cut
lengthwise as the wall ties into the other side of the building or into the intersecting wall or column. These
cut edges shall be covered with a metal trim as per the details.
Openings shall be cut in the panel for doors, win dows, borrowed light or other access openings as the panel is erected. It is important to remember that the proper layout can speed the job and re duce cutting, but care should be taken to avoid discontinuity of the standard panel width in the long exposed wall, regardless of the number of open ings or the wall intersections from the opposite side. Each panel set in place shall be meshed with the panel already erected so that there is a tight joint between the two sheets and each sheet is vertical. Do not hammer on localized points or areas, but use protection and a long strip in order to mesh the panels.
TOOL-A
SGP 0027248
After the panels are erected, the doors and jambs (hang door and trim one side on bench) shall be set in the openings and trimmed and the base and ceiling molding nailed in place. Where an opening has been cut in the wall section such that there is a hollow space (no strips in core area) at the opening, cut pieces from erected panels shall be fitted, glued on the sides and inserted around the opening in order to have a solid core at least 3" back from the edge of every opening to give substance and backing for the installation of the casing and trim.
Operation 2 :--
After Counter
sinking Bore Hole
with
Standard
Drill
ELECTRIC WIRING
All electrical work shall be under the electrical sub-contract. Flexible conduit or cable can be installed in the
erected wall from the floor or ceiling. Rigid conduit shall be installed after one side of wall is in place and can
be run in the core space vertically and along top or bottom of the panels. Where rigid conduit is used having an
outside diameter greater than
an 8" wide strip of V4" gypsum wallboard shall be installed down the strip
in back of the panels in place to provide a 1" core space (2J4" total width wall). See detailed plans. The oppo
site side of the wall is erected after the conduit is in place and inspected. If desired, the back board of the
panel may be gouged out to provide extra space for conduit without changing over-all thickness of wall. Avoid
cutting or marring face layer.
Note: Care should be exercised and 2V2" wide door jambs provided in all walls where rigid conduit is required. This means a 1" x 1%'' floor and ceiling runner and/or proper provision in every other item dependent on the width of the wall.
EXTERIOR WALLS
Where desired, the "C" Panel may be used to finish an exterior wall to match panelled appearance of interiors.
Where the exterior wall (or an existing interior wall) has a smooth true surface, the panels may be applied with a mastic strip in back of each rib and three screws used in the tongue (top, bottom and middle). The screws shall be long enough to pierce a material providing holding power. This can be determined by test.
Where the wall is rough masonry (or other imperfect surface) install a top and bottom runner first and then a horizontal furring strip about midway between the two. Attach "C" Panels with flat head nails or screws through tongue at the three supports using a cushion of mastic beneath the ribs over the supports.
In a new building with framed exterior walls, the "C" Panel may be nailed at top' and bottom and at mid height (to a stud or a horizontal block between studs). Insulation and a vapor barrier should be in the wall. A strip of mastic should be run down the groove of the "C" Panel just before it is meshed into the tongue of the "C" Panel in place to seal the joint and reduce air filtering at the joint.
In all cases, trim shall be installed as with interior partitions (see plan sheets for details).
PERMANENT INSTALLATION
One change in the specification for the movable installation is necessary to make it permanent. In place of a non-setting mastic, use Bestwall Laminating Compound on the back of the ribs in installation. All other details and specifications are as per plans, sheets 1 to 4 and the specifications for movable partitions.
DECORATION: As there is no Joint System in the wall area, a one coat paint job may be made for a flat, semi-gloss or gloss finish. Wood trim should have all nail holes puttied and be primed before final coat of paint. For best results entire wall including trim should be primed and then painted.
SGP 0027249
iJ
.)
SGP 0027251
TYPICAL SECTIONS
BESTWALL HUMMER SYSTEM "C"
Bestwall Hummer System "C" partition application in an office building.
SGP 0027254
FIREPROOF
Gypsum
&E5TWALL
6u^D/Ng^PRODUCTS
FIRESTOP BESTWALL GYPSUM WALLBOARD GYPSUM WALLBOARD GYPSUM SHEATHING GYPSUM ROOF DECKS JOINT SYSTEM BEDDING COMPOUND TOPPING COMPOUND CERTEX TEXTURE JOINT TAPE
SPACKLING COMPOUND PATCHING PLASTER
For further information and details:
BESTWALL CERTAIN-TEED SALES CORPORATION
120 East Lancaster Ave. Ardmore, Pennsylvania
-
DISTRICT OFFICES
ATLANTA 3, GEORGIA 141 2 Rhodes Haverty Building 1 34 Peachtree Street
BUFFALO 26, NEW YORK P.O. Box 2608 Amherst Branch
CHICAGO 4, ILLINOIS 208 So. LaSalle Street
CLEVELAND 14, OHIO 815 Superior Avenue
DES MOINES 9, IOWA 505 Fifth Avenue
DETROIT 4, MICHIGAN 305 Woodbrook Bldg. 5050 Joy Road
EAST ST. LOUIS, ILLINOIS 1 7th Street & Broadway
JACKSON 6, MISSISSIPPI P. O. Box 4625 Fondren Station
MINNEAPOLIS 2, MINNESOTA 509 Second Avenue, South
RICHMOND 4, CALIFORNIA 1014 Chesley Avenue
SALT LAKE CITY 1, UTAH 1 19 West 2nd, South
SUMMIT, NEW JERSEY 1 19 Summit Avenue
TACOMA 2, WASHINGTON 1718 Thorne Road
DALLAS 22, TEXAS P. O. Box 6030
KANSAS CITY 26, MISSOURI 1 248 Crystal Street
WILMINGTON 3, DELAWARE 201 1 Concord Pike
EXPORT OFFICE: 100 East 42nd Street, New York 17, Nev/ York
Ftm No. BW 58322
B-58 10ML
SGP 0027255
Pruned in U.S.A.
route slip
GP02
SGP 0027256
SGP 0027257
TWO-PLY GYPSUM LAMINATION
Two-Ply Lamination is an advanced system of wall and ceiling construction erected by laminating two plies of %" Bestwall Glass Fiber Reinforced Gypsum Wallboard to conventional framing. The first ply is nailed. The second is applied with adhesive and nails. It is the basic system for fire rated, durable walls and ceilings for residential and commercial work in new construction or remodeling.
FIRE RESISTANCE--One-Hour SOUND TRANSMISSION--38-43 db. STRENGTH--Two-ply lamination offers twice
the strength of one-ply application. LAMINATED CONSTRUCTION--Smooth surfaces--
monolithic finish.
WALL ELEVATION SCALE %" = l'O"
WALL SECTION
SGP 0027258
ft *
NOTE: Screws may be eliminated if joist spacing is 16' o.c.
TWO-PLY CEILING--Joist spacing 24" o.c.
SCALE 3" = 1'0"
i* ;f\ * .f- 5 Aimv* $+* f ; n. 8 ; ' v.:
SGP 0027259
Bestvvali research a?:.:! > .i.ineenng com am* Bescweili
Glass h::cr Reinforced Gypsum Worn .v.rd vviiii ihf.
.c.";'.,oehe;i0i'. . . crivepoed . p'-qu .-.
O'/venm u-1 vw.it! eon :;fr
s r.f-v :o:'.:po -pop;:,
v - neci o r i ` s, ovo" shies, iiopi'T.ot: on
ooo r.f, . . !o port,con . or u>
. sMal o on
!P'-. . WO"- i O v.'-P; `O'l-'ec, '
with suhod'rha! savings on material ana 'poor.
A stall ui .-.cstwal! System? Erginsors
mom const .'-coasi to
you in quorohy sur>
dotuiiirig one instaih".uon m dr/xX! systems to help
you mc'K /.;ur yequirenv`.*s.
'os uol.v'p.-. cats, chocp , `V-r ^
f or v.'Ua
di reedy to :p - Sesic-oh :rmoum Ccrnpmv.
BESTWALL HUMMER SYSTEMS
TWO-LAYER LAMINATION
FEATURES: 1. Fire Resistance:
One hour.
2. Sound Transmission Loss: .43-Decibels (Tested before 1957). 38 Decibels (Tested 1958).
3. Strength: ........................... Two-layer lamination has twice the strength of a single layer application.
4. Laminated Construction: ..Smooth monolithic walls created by unitized lamination of multi-plies of Gypsum Wallboard.
SPECIFICATIONS: All gypsum wallboard and joint'system materials used, includ ing laminating compound, shall be manufactured by the Bestwall Gypsum Company and shall be installed by a Bestwall Hummer licensed contractor in a first-class work manship manner.
FIRST (or back) LAYER (apply to ceiling first and then to sidewalls).
Backer Board: Use %" thick, 4' or 2' wide, square edge gypsum backer, applied at right angles to the framing.
Nailing: Use 1%" Drywall nails (or 1" long, divergent point staples). Ceiling spacing 5" to 7" o.c. Walls 6" to 8" o.c. Over metal framing use Bestwall Drywall screws or
attachments recommended by metal framing manufacturing specifications.
DO NOT DIMPLE BOARD. SECOND (or face) LAYER (apply to ceilings first and then to sidewalls).
Face Board: Use %" thick, 4' wide, 8' to 16' long, tapered edge Gypsum Wallboard (use wallboard with center taper on ceilings) applied at right angles to the framing. Joints in face board must not occur over joints in the first layer board (spaced 12" min.). Do not dimple board for nails or screws that are under tape or trim.
Laminating Compound: See Bestwall Product Sheet BW 62355. Apply glue to back of face layer with serrated metal blade or to face of back layer with machine glue spreader.
Note: For applying face layer which has a vapor barrier predecorated finish, use a ``contact type" adhesive.
Face Nailing: U 1%" long Drywall nails. Ceilings: Nail in edges and center taper at every nailing member. Sidewalls: Nail in edges only at every stud. Additional Fasteners: Use Bestwall Drywall screws in joints midway between joists or studs, if spaced more than 16" o.c. (as 24" o.c.). For sidewalls only, use a double-headed nail in the center of the sheet at every other stud to hold face board tight to back layer until glue hardens. Joint Treatment and Decorating: See Bestwall Product Sheet BW-62360.
-..' *-i3--t". 4, 4-1 . . ....j
.A NTA
l-.''. Peachtree
Building
5/20 Peach dec 3-5 cet, N. W.
A Js-ita, G. ore/ a " 17!C9
Phene: 404 97.';- :-C A I
BRUNSWICK
hoot O! I ii:'
tnanswick. Gen:". ,.i "1551
1 o: /: 915 33n : ' - .0
9 UCrtGO
. 9-14 VV. 51 Cii.v .l.vid A-', koiey, liimor: i. 1192 - './no: 3 i 5 I t " .110 Accai)
31 2 921 -8242 lAiuc/yo}
CLEVELAND
?r.V V.'ariensviHs Sr..~A.:,r Heights Ol/'z/.-rd, Cruc 4 PI.- "vj: 516 901 3
tier Road
:!
HOUSTON' Baycj Siuhoing 31] 5 Alien Parkway Houston. Texas 77019 Phm.e: 7.13 JA G-4474
IV LI.A3
All Exchemy- il/: I. Ci lump.
O. 4 Texas -' 7
; r -n... 714 m. 7
;
L" . *1 ;
r. - r : 1' '4 CiTY
Aid/e Uoulrivird
Kni(. Missouri 64:33
f'fiO"'... : 9 r L 3-8753
Sail:: 227. Of nae-.er h.mhue' 7T -2 ) 3' - xorir.-.ter hr-.;
FT.:', i ' 73; , Cl! 2-2540
SAN FRANCISCO 301 El Cc i.ito Plaza El Cemtu, California 94 932 Phone: 4if, 524-2495
WESTERN
Room **04, Tribune B j:!
3 4-3 So. Tain Street
Sak i
Ony, Utah S-liui
Phone- ACl EL S-20C7
*,; v ;
Wimur.
Marine Te;;-o:;.
./. Deiev.aie 147,7
Phone. 3V Ol. &-723J
;l
-.1
BESTWALL
HUMMER SYSTEMS
THE MOST ADVANCED METHODS OF GYPSUM WALLBOARD CONSTRUCTION
COMPARE THE COSTS
Bestwall Hummer Systems
Single Layer Application
PROVE to yourself how little it costs to get drywall performance of superior quality.
(,,tPoOF a'"sUM
MANUFACTURED BY BESTWALL GYPSUM COMPANY
Sold through: Bestwall Certain-teed Sales Corporation 120 East Lancaster Avenue, Ardmore, Pa
SGP 0027261
ESTIMATE OF MATERIALS AND LABOR TO CONSTRUCT 10
ITEM
CONSTRUCTION
DESCRIPTION
2" x 4" Framing (16" on-center)
2 1" x 2" Furring (16" on-center)
MISCELLANEOUS MATERIAL
NAILS
LABOR
HOURS
& COST
2" X 4'' 100 sq. ft.
'/1 lb.
;
2 hr.
80 lin. ft.
'''V .V,X 'h lb.
1 hr.
3 % " Bestwall Gypsum Wallboard (100 sq. ft. Wallboard applied to wood frame 16" on-center)
,-V-V ^
4 V2 " Bestwall Gypsum Wallboard (100 sq. ft. Wallboard applied to wood frame 1 6" on-center)
5 5/s " Firestop Bestwall Gypsum Wallboard (100 sq. ft. Wallboard applied to wood frame 16" on-center)
6 Bestwall Hummer System "A" (Solid Lamination) 100 sq. ft. one surface complete applied to wood frame 16" on-center
7 Bestwall Hummer System "D" (Strip Lamination) 100 sq. ft. one surface complete applied to wood frame 16" on-center
8 Bestwall Hummer System "B" Non-load Bearing Partition (100 sq. ft. gives 2 sides finished)
9 Bestwall Hummer System "C" Movable Partition Non-load Bearing (100 sq. ft. gives 2 sides finished)
10 Bestwall Hummer System "B" Self-Furring Wall
. iXrx W'-
L ' ,.
Back Bd. 100 sq. ft.
V2 lb.
30 min.
%" Strips
33 sq. ft.
Wood Runners
1" x 1 s/B" 30 lineal ft
'/} lb.
15 min.
)
% lb.
30 min.
Wood Runners
3/T x l5/a"
30 lineal ft.
% lb.
30 min.
Shims 20
Mastic 1 Pt.
15 min.
1 1 Bestwall Hummer System "C" Self Furring Wall
20 1 Pt.
1 5 min.
12 V2" Bestwall Gypsum Wallboard over masonry wall on furring 16" on-center; Line 2 plus Line 4
13 Bestwall Hummer System "D" (Strip Lamination) 23' x 35' Ceiling
14 Back Blocking; 23' x 35' Ceiling
r-L
% * 8" strip
305 sq. ft.
,
Cuttings 245 sq. ft.
1 lb.
'/< lb.
2V2 hrs.
. V-
4 hours
SGP 0027262
> SQ. FT. WALL (12V27 LONG - 8' HIGH -- NO OPENINGS)
GYPSUM WALLBOARD MATERIALS (FACE)
FACE GrPSUM RIBS GYPSUM
WALLBOARD
ADHESIVE
NAILS
SCREWS
LABOR HOURS & COST
FINISHING MATERIALS
TOTAL COSTS (INCLUDING 25% PROFIT)
METAL CORNER BEAD
LABOR
TAPE
JOINT TREATMENT
CEMENT
LABOR HOURS & COST
100 SQ. FT. (ONLY)
FINISHED WALL 100 SQ. FT.
SURFACED ON BOTH SIDES
H?-
\'
V.
Not Applicable
C! '
,
Not Applicable
100 sq. ft.
Vt lb.
35 min.
1 ft.
1 ft.
40 ft.
5 Ib.
40 min.
100 sq. ft.
y2 ib.
40 rhin.
1 ft.
1 ft.
40 ft.
5 Ib.
40 min.
100 sq. ft.
y> ib.
k./'.r y 45 min.
' '-j '
\ ;;
100 sq. ft. %" Board
Lam. Comp. 1.6 lb.
y. ib.
6 45 min.
100 sq. ft.
0.6 lb.
'/. lb.
6 45 min.
1 ft. 1 ft.
1 ft.
1 ft. 1 ft. 1 ft.
40 ft.
5 Ib.
40 min.
40 ft.
5 Ib.
30 min.
40 ft.
5 Ib.
30 min.
1" Ribs 6 Vi "
& 3Vz" 34 sq. ft
200 sq. ft. % Firestop
lam. Comp. 1.5 lb.
0.1 lb.
M ' V?
"C" Panel 24" width 200 sq. ft
Mastic (Non-setting)
0.1 Ib.
:,;S
r Ribs 6 V*" & 3Vz" 34 sq. ft.
y2" Board
Lam. Comp. % lb-
0.1 Ib.
20 2 Vi hr. 2 ft.
2 ft.
80 ft.
10 Ib.
1 hr.
Not Applicable
Moulding
20
2y, hr.
40 ft.
40 ft. mldg.
#105 sq. edge
Not Appficabfe
10 1'/, hr.
40 ft.
5 Ib.
30 min.
Not Applicable
-7
; S'
-'
Pt
"C" Panel 24" width 100 sq ft
-,,1
0.1 Ib.
- . ,
-V
<
1 >/, hr.
Moulding
20 ft
20 ft. mldg.
#105 sq edge
&r: /
.y Y?" Face Board lam. Comp.
830 sq. ft (C Taper)
5 lb.
; -
v ", .r*'p v;
Joint Cement 830 sq. ft.
15 lb.
1 lb. 5 Ib.
-
235 6% hr.
, i 320 ft.
40 tb.
5'/4 hr.
;t>- ,r,. ;; . V >- . - ', '
V:',, .
320 ft.
40 Ib.
4 hr. 4 hr.
Not Applicable
Not Applicable
Not Applicable
Not Applicable
SGP 0027263
Get your copy of detailed plans and specifications on the following 4 systems
BESTWALL HUMMER SYSTEM "A" This is an improvement of the oldest and simplest laminated wallboard con struction. Application is made over framed walls and ceilings. The first layer is nailed; the second layer is applied with adhesive and screws. A tapered edge board with a center taper is used on the ceiling. This system eliminates nail popping and joint beading and provides a perfect installation.
BESTWALL HUMMER SYSTEM "B" This system was developed to provide walls without frame or support of any material other than gypsum wallboard. Designed for interior non-load bearing partitions or for simple, self-furring, free-standing wall surfacing over masonry walls. The interior partition provides one hour fire resistance.
BESTWALL HUMMER SYSTEM "C" A factory-fabricated narrow panel of several layers of gypsum board, de signed for non-load bearing walls where joints are left unfinished and for movable partition construction. Special edges give an attractive paneled effect. The panel can be erected, trimmed and painted in one day because there are no nails in the surface or joints to be treated.
BESTWALL HUMMER SYSTEM "D" This application (Strip Lamination) is designed to prevent joint beading and delayed shrinkage and to eliminate nail "popping" at lowest cost, by putting all nails and fastenings under joint system tapes and trim. This system is less expensive than a standard two-layer application, yet the finished wall closely matches a complete double layer installation in performance.
Bestwall Gypsum Co. 120 E. Lancaster Plants & Offices in Principal Cities
Ardmore, Pa.
SGP 0027264