Louisiana Division Consolidated Audit Hazardous Materials Transportation Review March 1991 Dow Confidential DO A 077579 OONFTDFNTT Al HAZARDOUS MATERIALS TRANSPORTATION PLANT: Cell Service_____________________________ BUILDING: 5601_________________________________ REVIEW DATE & TIME: 3/25/92 - 8:30-10:00 A..M. HAZARD MATERIALS TRANSPORTATION TEAM: SUPERINTENDENT: Roddev Peebles______________ LOSS PREVENTION: Dean Smith__________________ SAFETY ENGINEER:__________________________________ TECHNOLOGY CENTER: Chlor-Alkall______________ DEPARTMENT PERSONNEL:________________________ SECTION MANAGER:___________________________ MAJOR MANAGER: Tom Austin_________________ (To be completed by the Superintendent) 3/13/9 2 DOW CONFIDENTIAL no A 0??F80 GONFTOFNTT At Louisiana-!!)! vision March 1991 Dow U.S.A The Dow Chprmc.il Comiisw I'O Uo> lr.(l Plaouernine Lomsifin.'i 0 1 Ml To: Plant Superintendent/Department Head SUBJECT: HAZARDOUS MATERIALS TRANSPORTATION REVIEW (HMTR) The HMTR audit will be part of the Louisiana Division Consolidated Audit Process. The audit will be the responsibility of the Superintendent/Department Head. The purpose of this audit is to provide an in-depth review of our Louisiana Division hazardous materials transportation practices of materials which, if released, could possibly cause injury to the public. The audit will be reviewing the chemicals shipped or received, including the plant's waste materials with a Hazardous Materials Transportation Index (HMTI) of 2, 3, or 4. (Does not include pipeline transportation). You should begin your preparations by reviewing the attached program guidelines and developing or updating the HMT Indexes for your plants' various chemicals and potential loss of containment from worst case transportation scenario. You will need to complete and send a copy of the review package to the Audit Facilitator ten (10) calendar days prior to the audit. A HMTR Audit Team is required for a HMTI of 2, 3, or 4. A U.S. Area Loss Prevention Representative will be required for a HMTI of 3, or 4. A HMTI of 1 requires a review by the Superintendent and his Manager only. NOTE: Prompt response to the HMTI calculations is necessary. A 30 day pre-audit notification to the U.S. Area will be necessary for some materials. Contact Dean Smith at extension 8879 for U.S. Area Loss Prevention Representatives as audit team members (required for HMTI's of 3 or 4). Dean should also be contacted for a Functional Audit Team if the HMTI of materials is 2, 3, or 4. DO A 0005B1 GONFTDFNTTAl March 1991 Page Two The list of contacts below can be used as additional resources. Ind. Hygiene Purchasing Loss Prev. HMTl CEI F&EI Safety Gary Meier Randy Normand Buck Bailey Dean Smith Jim Gibson Maurice Oubre Don Jones 1809 8481 1539 8879 8163 8953 6097 Attached are the "Guidelines for a Hazardous Materials Transportation Review ", including the Audit Instructions which give the details about what is needed to prepare for the audit and how the audit will be conducted. If there are any questions concerning the audit, please contact me at extension 8879. Dean Smith HMTR Functional Team Leader Building 3302D Ext. 8879 I> CD DO A 0??f> OONFTDFNTT CHEMICALS USED IN THE CELL SERVICE BLOCK H. MATLAUDIT. DO w.3/9/92: LLM DOW CONFIDENTIAL DO A 077583 OONFTDFNTTAl 10 ACETONE (MAY BE USED IN CA#2 AND CHLORINE BLOCKS) ACETYLENE AIR ARI SANITIZER DEODORIZER (USED FOR CLEANING OF RESPIRATORS) ASBESTOS USED IN CATHODE DRAWING AND PULP CELL PUTTY CHLORINE (IN CHLORINE AND CA#2 BLOCK - TURNAROUND) COBALT NAPHENATE 6% (HARDING AGENT FOR DERAKANE) COPPER DERAKANE DIESEL FUEL (DMA) DIMETHYLANILINE (ACCELERATOR) DB-1430 ANTI-FOAM FREON - R22 GAS UNLEADED HEAT HYDROGEN (IN CHLORINE AND CA#2 BLOCKS - TURNAROUNDS) HCL HYDROCHLORIC ACID (IN CHLORINE AND CA#2 BLOCKS - TURNAROUNDS) KYNAR (R) 32 (BONDING AGENT) LIGHT BULBS LOCQUIC (PRIMER N AERSOL) MEROPA 220 OIL MEROPA 320 OIL MEROPA 460 OIL MEROPA 680 OIL MOBILARAMA 247 OIL (METAL PRESERVATIVE) MOBIL RARUS 427 MOBIL SHC 824 MOLUB-ALLOY CHAIN OIL 22 ROYAL PURPLE THERMYL-GLYDE (SYNTHETIC LUBRICANT IN CR-501 GEAR BOX) MEKP (METHYL ETHYL KETONE PEROXIDE, ACTIVATES DERAKANE) METHANES MINI FIBERS (POLYETHYLENE) NICKLE OXIDE (TREATMENT FOR BACKBOARD GASKET SEALER TO HELP PREVENT CREVICE CORROSION ON TITANIUM BACKBOARDS) NICKLE POWDERS (NOVAMET R CONDUCTIVE NICKLE) NITROGEN OXYGEN PLURONIC F-108 DO A 070504 CONFTDFNTTAl 01/27/92:DW POLYMER 1165L FLOC PST PIPE SEALANT #567 90 (1 LITER STAINLESS STEEL PST, BACKBOARD GASKET SEALER) RANDO OIL HD68 REGAL OIL R & O 32 REGAL OIL R & O 68 REGAL OILR&O 150 REGALOILR&O 220 ROOF FLEX (USED TO FILL HOLES IN THE CONCRETE) AND (USED ON TURNAROUNDS AT CHLORINE AND CA#2) STANNIC OXYCHLORIDE (USED IN FIT TESTING) STYRENE MONOMER (VAPORS FROM DERAKANE) SULFURIC ACID (IN CHLORINE AND CA#2 BLOCKS - TURNAROUNDS) TEFLON FIBERS (FLOUROCARBON FIBER) 7C TRANSMISSION FLUID TRITON DF-12 (WETTING AGENT) TRITION X-114 (WETTING AGENT) URSA SUPER PLUS SAE 10W URSA OIL EXTRA DUTY 30WT WELDING RODS WELD SEALANT/GRADE AA #89 01/27/92:DW DO A 0??585 CONFTDFNTTAl CAUSTIC SODA 50% (EXPERIMENTAL) CELL EFFLUENT TEFLON FLOUROCARBON (TEFLON FIBER) MISTRON VAPOR TALC SAFFIL - ALUMINA FIBER H.MATLAUDIT.DOC:3/9/92:LLM DO A 0??586 OONFTDFNT TA1 DOW CO.,. jENTiAL 11 CHEMICAL OF CONCERN: ASBESTOS H.MATLAUDIT.DOC:3/2/92:LLM PRODUCED FOR THE ASBESTOS DATABASE DATE: 2 ~/2 ~ 9 7MASTER No 43 'PS 3" DOW CONFIDENTIAL DO A 0??587 CONFTDFNTTAl 12 February 24, 1992 Dean Smith HMTI Functional Team Leader Building 3302D HAZARDOUS MATERIAL TRANSPORTATION INDEX ASSIGNED TO ASBESTOS IS "I" Because asbestos is relatively inert, the FEI calculation cannot be made. The computer program is not designed for materials like asbestos (M. Oubre). Also there are no available dermal LD50 numbers to calculate skin effects (B. Heinze). Please see next two pages. The "calculated" HMTI would be less than 1. However, asbestos is carcinogenic and with your recommendation an HMTI of 1 will be assigned. John Lewis Cell Service H.MATLAUDIT.DOC:3/2/92:LLM DO A OF?588 CONF TDFNTTAl PRODUCED FOR THE ASBESTOS DATABASE DATE: (2- <f ~_____ ______________ Dow cotMiSgfiftiHa. .i 3 OCT-30-'91 13:19 ID:DOW CELL SERUICE LA TEL HO:504-389-6070 To: H > 4- '-(/ ^HetiT 8245 POT -L Zi'oze Fa* #o> HAZARDOUS MATERIALS TRANSPORTATION ^ l&\/} $ REVIEW QUESTIONNAIRE ?/)>( 6f2> III. HEALTH AND ENVIRONMENTAL EFFECTS 7. ^ ^ _ n F-o/z4$et>7o$ ? 1. What 1$ acute toxicity of the materials? 7c r, - Inhalation (LC50 In ppm) /w&n*/%,. Dermal (LD50 In mq/ko) nM___________________ - Oral (LD50 In mg/kg) l. Are potential health effects reversible? Yes [] No ft 3. Can people readily escape contaminated areas? Yes No[] 4. What Is effect on aquatic life? ____ a/* '/UZ, 5. Does material biodegrade? Yes [J No 6. Would a spill cause long-term groundwater toxicity problems? Yes () No JH' 7. Does material exhibit any warning properties? Yes [] No N 6. Is material corrosive to skin? Yes [] No pi 9. Has recommended protective equipment been tested? Yes JA No [] 10. Please Submit - A Material Safety Data Sheet (MSDS) -- A Transportation Equipment Data-Emergency Response Sheet (TEDER) DO A 022589 CONFTDFNT TAl w** * PRODUCED FOR THE ASBESTOS DATABA' DATE: SzA'Z n Q-4 MASTER No. qct-28-'91 MON 16:38 ID:LAD-TECH CENTER 6650 TEL NO:FAX 504 389 6160 OCT-28-'91 1H5? ID:DOW CELL SERVICE LA TEL NO;504-389-6070 8340 P01 8243 P01 to Mflvuce 'o/zfp. SAMPLE OUTPUT FROM LOTUS 1-E-3 PROGRAM HAZARDOUS MATERIAL8 TRANSPORTATION REVIEW ' CEL PAEI, AND SKIN RANK CALCULATIONS (REVISED 1/14/90) TANK CAR ' STYRENE C/w You P/zqvioe, Fok As&esros, %>$ tfi/At&GZS ? INPUT DATA HUIIItMIIIIMlilMimilMlMMI eEPO_CON.CENTRATIQN^> _ IIIIIHIIntMilM "MATERIAL FACTOR(FAEl GUIDE) .| A NFPA HEALTH RATING (Nh) * 1 NFPA FLAMMABILITY RATING (Nl) BTU'fiJ>gBMl.B8 "MOLECULAR WEIGHT h 1 VAPOR PRESSURE MM HO $2S DEG C rt THERMAL INSTABILITY 06G C PHYSICAL'STATE PENALTY VI8COU5 LIQUID............. ,70 LIQUID.................... . 1.00 ' COMPRESSED GAB..............1.30 LIQUIFIED FLAM OA8 -- 1,90 ^ LBS OF PROOUCT PER CONTAINER *' SHIPPING PRESSURE(PSI OF MATERIA ) RELIEF VALVE SETTING (LBS) ,, DERMAL 1050 FOR 8KIN EXP08URG vV 17.00 150,000 5 78 . 2,001 .V TtJAAfKSj x/oAtrj Cewis fly, 0/7o p*#dfic SUMMARY #tIIII CEI 64.00 FAEl 142.22 SKIN RAN 0 T C4iCKP CoWOMM* Zftfuj'j-y aW O ^ 4 TVrr*rr TVttfS'* jWO G-'Vf*>'wA f~* A Sc^4r^.AL c.\vc-4 IIMIIM ' M | Mil MtlktM *! CALCULATED FACTORS........ , YW O CHEMICAL EXPOSURE INDEX RANKING ACUTE HEALTH HAZARD FACTOR ACUTE HEALTH FACTOR 8CALE LBS VAPOR RELEASED IN 15 MIN, VAPOR QUANTITY SCALE * DISTANCE 8CALB# MOLECULAR WEIGHT SCALE # SHIPPING PRESSURE FACTOR THERMAL INSTABILITY FAOTOR PROCESS PENALTIES FACTOR PROCESS PENALTIES 60ALE * CHEMICAL EXPOSURE INDEX CHEMICAL EXPOSURE SCALE If 21714.2S 1,00 8B3.6S 2.00 4.00 4.00 0.00 2.00 2.00 2.00 64.00 1.00 PRODUCED FOR THE ASBESTOS DATABASE t*UP(TT,>l*l'llftPffil<*1 * '/ ymnnimiiit >>>m>>4 wmw .4.3/txr - FIRE A EXLQSION INDEX RATING MATERIAL FACTOR GP BASE FACTOR HANDLING & TRANSFER FACTOR ACCESS FACTOR SPILL CONTROL FAQTOR FI -GENERAL PROCESS FACTOR 24.00 1.00 0.65 0.3S 0 50 2.70 SP BASE FACTOR 1.00 TOXIC MATERIALS FACTOR PROCESS OPERATION, PURGE FACT 0.40 0,30 QUANTITY IN 8TORAGE FACTOR IGNITION SOURCE FACTOR (FIRED HT 0.40 0.00 OPERATING PRESSURE FACTOR 0.09 F2-8PECIAL PROCESS HAZARDS FACT 2.19 ............ . MMItMIIKtMtMKIMIMIM.iMM II I M F3-UNIT HAZARD FACTOR (-F1-F2) FAEI-FIRf A EXPL08ION INDEX 5 93 142.22 FIRE A EXPLOSION RANKING 4 r> 33 ZO Tt 3-t T> Tj 3 Z--t \\>> --t Cn X-> ^o0 HAZARDOUS MATERIAL COVERED IN AUDIT: ASBESTOS NATURE OF HAZARD: Extended exposure to certain airborne friable asbestos particles can cause asbestosis, lung cancer and mesothelioma. Asbestos is not considered hazardous by DOT and is not regulated. It is non-flammable, non-explosive, non-reactive and does not affect the skin. Public perception places asbestos in the "Hazardous" category. H.MATLAUDIT.DOC:3/2/92:LLM PRODUCED FOR THE ASBESTOS DATABASE DATE: 3'/%. ____________________ MASTER No. jLUtfS qtu. DOW CONFIDENTIAL DO A 070591 OONFTDFNTTAl 14 TRANSPORATION INCIDENTS WITHIN LAST TWO YEARS: NONE H.MATLAUDIT.DOC:3/9/92:LLM n0 A 0??59? CONFTOFNTTAl DOW CONFIDENTIAL 16 ITEMS REQUIRING ACTION FROM PREVIOUS HMTR AUDIT: NONE: THIS IS THE FIRST AUDIT H.MATLAUDIT.DOC:3/9/92:LLM oo OONF DOW CONFIDENTIAL 17