Document 99oDeggek5k603MZ1grEyXyYL
Americajv-&tandard
i.l.n. it/11
1 s. r ijjtMrU
Hydronic Heating Equipment
trade price book
c^fU l
Hydronics ... the science of heating and cooling with water.
PRODUCTS
Boilers:
Gas--Packaged Units
Boilers Only
Electronic Control Systems
Oil--Packaged Units
Boiler--Burner Units
Boilers Only
Stoker Boilers
Hand fired Boilers
Radiation:
Baseboard Panels--Radiantrim
--Heatrim
Convectors
--Multifm
--Arco
--Cabinet Extras
Radiators--Arco, Sunrad, Peerless
Oil Burners and Controls
Zone Valve Packages
Repair Parts Discounts
Terms
General Information
PAGE
3-6 7-14
15 16-18 19-27 20-27 31-33 34-36
38 39-40 42-44
41 45 37 28-30 30 2 46 2
r
HH-4
JANUARY 2, 1964
notice: The Trade Prices shown herein do not include freight or cartage, installation or any local taxes.
L/\me rican -Standard
PLUMBING AND HEATING DIVISION
AMERICAN RADIATOR & STANDARD SANITARY CORPORATION 40 WEST 40TH STREET NEW YORK, N Y. IOC
04642
GENERAL INFORMATION
American-Standard
HYDRONIC HEATING
BOILER RATINGS
Boiler ratings ("net I = B=R ratings of Mbh and sq ft of steam 1 net rating sq ft water" and "installed radiation", where rhcv.T.! represent the rr.exirr.'-rr. r.ct leads that may be connected to the boilers. Steam sq ft ratings are based on 240 Btu per sq ft and water sq ft ratings on 150 Btu (170* wateri per sq ft. Allowances have been made in these ratings for normal piping (covered) and pick-up loads and for heat ing domestic hot water under the following conditions:
It is not necessary to increase the boiler size for domestic hot water supply when not more than two bathrooms are to be served or if the use of domestic hot water does not exceed seventy-five gallons in twenty-four hours.
Sufficient radiation must be installed for the requirements of the building.
In order to select the proper size boiler calculate the heat loss of the building, then divide this figure by 1,000 to get the heat loss expressed in Mbh. Select a 5team Or Water bvaiel which has a net Mbh rating equal to or greater than this fig ure using the appropriate steam or water column.
See current literature for determining the size of radiators and convectors for hot water systems.
For an installation where unusual conditions such as large pipe losses, intermittent heating, unbalanced systems, etc., are encountered, it is suggested to calculate the actual piping loss and estimate the pick-up factor to adjust the load and then select the boiler from the published gross output in Mbh (1,000 Btu per hour).
GAS FIRED BOILERS
The input and output ratings are approved by the American Gas Association.
Ratings shown are for installations at sea level and at eleva tions up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
OIL FIRED BOILERS
The firing rates or I=B=R burner capacities-gallons per hour --are based on the use of oil having 140.000 Btu per gallon heat value, and with 10% CO; in the flue gas.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
When Built-in Tankless Heater is used increase the boiler size 12 Mbh for each bathroom in excess of two.
STOKER FIRED BOILERS
The firing rates or I=B=R burner capacities-pounds per hour -are based on the use of coal having 13,000 Btu per pound heat value.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
HAND FIRED BOILERS
The ratings (installed radiation sq ft) are based on the use of stove or nut size bituminous coal, anthracite coal or coke with 13.000 Btu per pound heat value. See table below for select ing proper size boiler when using coal with less than 13.000 Btu per pound.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
BUILT-IN WATER HEATERS for A-3, A-5, LA-77. Severn and Exbrook Boilers
All tank type built-in water heaters are rated on the basis of raising the temperature of the domestic hot water 100*F. in three hours with a minimum boiler water temperature of 180`F. on automatically fired boilers and 212"F. on hand fired boilers.
All tankless type built-in water heaters are rated in gallons per minute on the basis of a minimum boiler water tempera ture of 180"F. on oil fired boilers. The maintaining of 180'F.
boiler water temperature with rated flow through a tank less type built-in water heater is dependent on the oil firing rate for the boiler.
In those areas where excessive lime exists in the water, use of built-in tankless type water heater is not recommended except when provision is made for regularly cleaning the heater. Use of tank type heater is recommended in hard water areas.
WHEN PIPING LOSS IS NEGLIGIBLE
The load connected to automatically fired water boilers may be increased by 12% when the piping loss of the installation is negligible. The load connected to steam boilers (all fuels) and coal ihand fired) water boilers may be increased by the percentages shown below when the piping loss of the installa tion is negligible.
load installed radiation sq ft
Steam (all fuels)
Water coal (hand fired)
increase load
by
up to 250 251-- 500
501-1000 1001-1500 1501-2000 2001-3000 3001-4000
over 4000
up to 400 401- 800 801-1600 1601-2400 2401-3200 3201-4800 4801-6400 over 6400
30% 28% 24%
21% 18% 15% 13% 12%
WHERE COAL HAS LESS THAN 13,000 BTU CONTENT
When selecting hand fired boilers for burning coal of lower heating value than 13.000 Btu per pound the following correc tion factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq ft).
heating value of coal
correction factor
13,000.......... .... 1.00 12,500.......... . . .1.04
12,000.......... . . . .1.08 11,500.......... . . . .1.13 11,000.......... . . . .1.18
heating value of coal
correctic factor
10,500.......... . . . .1.24 10,000.......... ____ 1.30 9,500.......... ... 1.37
9,000.......... .... 1.44
INSTRUCTIONS FOR ORDERING GAS BOILERS:
Specify complete boiler number. Specify type of gas (if LP gas, whether butane or propane), Btu (heat
value of gas), specific gravity. Specify elevation at point of installation if in excess of 2,000 feet and
indicate barometric pressure. Specify optional equipment in detail.
REPAIR PARTS-TRADE PRICES
Boilers (all fuels) ............................................................................................................................................................List Price, less 25%
(aas Conversion Burners .......................................................................................................................................... List Price, less 25%
_ Oil Burners
for List Prices see "American-Standard Radiatqr Heating Repair Parts Catalog" 1956 Edition. ......................................................................................................................................................... List Price, less 25%
________________ ror List Prices see "American-Standard Arcoflame Oil Burner Repair Parts Catalog" 1956 Edition.
MH-4
Page 2
This Price List has been prepared for the convenience of American-Standard distributor* and their trade cus
tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable sell and distribution expense and do not purport to represent actual prices prevailing in any particular mar
04643
WATER -J*. " packaged
boiler number
GPR 60 GPR-80
WATER
GPR-60 GPR-80
AMERiCAN'<$tandard
HYDRONICHE AT ING
packaged boilers
GAS
GPR PACKAGED AMERiCAN-^tandard GAS BOILERS
Designed and equipped with controls lor lorced circulation. Factory assembled and crated. Built-in air-separator in top section.
A.G.A. approved for combustible floor and closet installations. Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and up to 2,000 feet.
for Natural, Manufactured, Mixed, Gas
controls arranged for non-100% shut-off
A.G.A. Input Mbh
75 100
A.G.A. output
Mbh
nt
l=B=R rating
Mbh
nat rating tq. ft. water
Trade Price with
standard
equipment
chimney size
diameter inches
height feet
60
45
300
$225.00
5
20
80 60 400 245.00 5 20
for Propane and Butane Gas
controls arranged for 100% shut-off
70 56 42 280 $225.00 5 20 95 76 57 380 245.00 5 20
approx. shipping
weight
205 235
205 235
Standard equipment all boilers:
V-600 combination diaphragm gas valve furnished for all gases. V-600 fea tures built-in gas pressure regulator (except for LP gas) and thermocouple type safety pilot switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); drain valve; draft hood; insulated round jacket; transformer; ASME relief valve (30 lbs.); pressure and temperature gauge (30 lbs.); wiring harness; 1" circulator; CB-58009 thermostat; AY-553 and AY-686 limit controls with HI-LO limit selector switch.
Ordering Examples:
1. Packaged boiler with standard equipment: 1 GPR-60 boiler Nat. gas, 1000 Btu, .6 sg.
2. Packaged boiler with optional equipment: 1 GPR-80 boiler with pilot filter with selfenergizing controls MM. gas, 550 Btu, .65 sg.
Notes:
For ordering instructions, see page 2.
For complete information on boiler ratings, see page 2.
For discount on repairs, see page 2.
Note: Packaged boilers are shipped with jacket, all controls (except thermo
stat), circulator, main burners and manifold controls and piping factory in
stalled and wired. CB-58009 thermostat, manual shut-off valve, relief valve
and draft hood shipped inside boiler crate.
Optional equipment:
04644
Pilot filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes.
Self-energizing controls (consist of special gas valve, thermostat, pilot burner, limit control) for all gases listed above, available when specified on order at no additional charge.
Note: In areas where manual opening feature is normally desired, GPR boil ers are furnished with self-energizing controls as shown above. V-600 gas valves with manual opening for GPR not available.
Zone valve packages are available for water boilers. For details and prices, see page 30
Page 3
This Price List has been prepared for the convenience of American-Standard distributors and their trade cusimers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling nd distribution expense and do not purport to represent actual prices prevailing in any particular market
HH-4
PACKAGED BOILERS GAS FIRED
WATIt
American-Standard
HYDRONIC HEATING
GPH PACKAGED American-Standard GAS BOILERS
Designed and equipped with controls for forced circulation. Factory assembled and crated. Square jacket. Built-in air-separator in top section. A.G.A. approved for combustible floor and closet installations. Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2,000 feet.
WATER
For Natural, Manufactured, Mixed, Gas
packaged
boiler number
A.GJL Input Mbh
A.GJL
output Mbh
net |=B=R rating
Mbh
net rating
q ft
water
Trade Price with
standard equipment
GPH-lOO GPH-135 GPH-170
125 100
75
500
$280.00
169 135 101 673 340.00
213 170 128 853 400.00
chimney site
diameter inches
height feet
6 20 7 20 7 20
WATER
For Propane and Butane Gas
GPH-100 GPH-135 GPH-170
120
96
72
480
$280.00
6
20
160 128
96
640
340.00
7
20
200
160
120
800
400.00
7
20
approx. shipping
weight
315 360 400
315 360 400
Standard equipment all boilers:
V-600 combination diaphragm gas valve, arranged for 100% shut-off, fur nished for natural, mixed and LP gases. V-600 features built-in gas pressure regulator (except for LP gas) and thermocouple type safety pilot. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); drain valve; draft hood; insulated square jacket; transformer; ASME relief valve (30 lbs ); pressure and temperature gauge (30 lbs.); wiring harness; 1V" circulator; CB-52502 thermostat; AY-553 and AY-686 limit controls with HI-LO limit selector switch.
Non-100% shut-off with self-energizing controls furnished for manufactured gas. Self-energizing controls consist of special gas valve, thermostat, pilot burner and limit controls.
Note: Packaged boilers are shipped with jacket, all controls (except thermo stat), circulator, main burners and manifold controls and piping factory installed and wired. CB-52502 thermostat; manual shut-off valve and relief valve shipped inside boiler crate. Draft hood shipped separately.
Ordering Eiimples:
Optional equipment:
1. Packaged boiler with standard equipment: 1 GPH-135 boiler Mfd. gas, 550 Btu, .65 sg.
2. Packaged boiler with optional equipment: 1 GPH-100 boiler with self-energizing controls Propane Gas
Notes:
For ordering instructions, see page 2. For complete information on boiler ratings, see
page 2. For discount on repairs, see page 2.
HH-4
Pilot Filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes.
Self-energizing controls (consist of special gas valve, thermostat, pilot burner, limit control) for all gases listed above, available when specified on order at no additional charge.
Note: In areas where manual opening feature is normally desired. GPH boil ers are furnished with self-energizing controls as shown above. V-600 gas valves with manual opening for GPH not available.
Zone valve packages are available for water boilers. For details and prices,
see page 30.
----------------------------------------------------------
04645
Page 4
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus-
vn represent fixed markups over distributor prices to reflect reasonable selling
not purport lo represent
n'ices prevailing m any particular market.
American-^Standard
HYDRONIC HEATING
PACKAGED BOILERS GAS FIRED
WATCR
G-2 PACKAGED AMERlCAN-^landard GAS BOILERS
Designed and equipped with controls lor forced circulation. Factory assembled and crated. Deluxe jacket.
Sections tested for 30 lbs. water working pressure.
"Eliminaire" (cast-in air separator in left end section). Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2.000 feet.
WATER
packaged
boiler number
A.GJL
Input Mbh
A.GJL output
Mbh
tankless haatar numbar
A |=W=H rating
NaU Mfd.. Mixed and LP Gas LP-Air Gas 52S-1400 Btu
net l=B=R
rating Mbh
net rating
sq ft water
Trade Price with standard
equipment
chimney size
diameter hsight
inches
fast
approx. shipping
weight
Packaged boilers with factory installed tankless heater
G-24-DPT G-25-DPT G-26-DPT G-27-DPT
90 120 150 180
72 218 2>/2 96 222 3 120 222 3 Vi 144 222 3 Vi
54 72 90 108
360 480 600 720
$375.00 421.00 464.00 500.00
5 20 390 6 20 470 6 20 550 6 20 642
Packaged boilers without tankless heater
G-23-DP
60 48
G 24-DP 90 72
G-25-DP
120
96
G-26-DP 150 120
G-27-DP 180 144
36 240 54 360 72 480 90 600 108 720
$285.00 342.00 386.00 429.00 465.00
Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature.
4 20 315 5 20 375 6 20 455 6 20 540 6 20 630
Standard equipment all boilers:
V-600 combination diaphragm gas valve furnished for Natural. Manufactured, Mixed, LP-Air, and LP gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Drain valve; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs); Pressure and temperature gauge (30 lbs.); Wiring Harness; lW circulator with piping.
Additional standard equipment for boilers with heater:
Tankless heater as listed above. combination immersion control (high and low limits, circulator operation, transformer and built-in relay), CB-52502 thermostat.
Additional standard equipment for boilers less heater:
CB-52502 thermostat, combination immersion high limit and reverse acting control. Left hand end section without tankless heater opening.
Note: Packaged boilers are shipped with jacket, all controls (except thermostat), cir culator and piping, main burners and manifold controls and piping factory installed and wired. CB-52502 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton for G-23-DP.
Ordering Eiimples:
1. Packaged boiler without tankless with stand ard equipment: 1 G-24-0P boiler Nat. gas, 1000 8tu, .6 sg.2
2. Packaged boiler with factory installed heater with optional equipment: 1 G-26-0PT boiler with push buttpn elec tric ignition Mfd. gas, 550 Btu, .65 sg.
Notes: For ordering instructions, see page 2. For optional equipment, see page 9. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04646
Page 5
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only The trade prices showr----------------................................... ....... ' -lbutor prices to reflect reasonable selling
and distribution expense and do n
es prevailing in any particular market
HH 4
PACKAGED BOILERS GAS FIRED
WATIB
American-Standard
HYDRONIC HEATING
WATER
packaged boiler
number
G-23-DPG G-24-DPG G-25-DPG G-26DPG G-27-DPG
3-2 PACKAGED ALL-FuRPGSc j^MERICAA'cSlaiiuarii GAS BOiLcRS
Designed for forced or gravity circulation. Factory assembled and crated Deluxe Jacket.
Sections tested for 30 lbs. water working pressure.
"Elimmaire" (cast-in air separator in left end section). Controls regularly furnished for 115 volt. 60 cycle current. Ratings shown are for installation at sea level and up to 2,000 feet.
A.G.A. input
Mbh
A.G.A. output
Mbh
Nat., Mfd.. Mixed and LP Gat; LP-Air Gas 525*1400 Btu
net l=B=R rating
Mbh
60 48 36
90 72 54
120 96 72
150 120
90
180 144 108
net rating sq ft water
240
360
480
600
720
Trade Price with
standard equipment
less thermostat
chimney size
diameter inches
height feet
$208.50 4 20 265.50 5 20 309.50 6 20 350.50 6 20 386.50 6 20
approx. shipping weight
317
377 457 542
632
HH_4
Standard equipment:
V-600 combination diaphragm gas valve furnished for all gases. V-600 fea tures built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch.
Manual shut-ofF valve; pilot cock; pilot filter (for manufactured gas and S.U.R.) ; drain valve; draft hood, insulated jacket; transformer. G-23-DPG furnished without heater opening in left end section.
ASME relief valve; pressure and temperature gauge; CB-65653 immersion limit control. Draft hood shipped in separate carton for G-23-DPG.
Ordering Examples:
1. Packaged all purpose boiler with standard equip ment:
1 G-25-OPG boiler Nat. gas, 1000 Btu, .6 sg.2
2. Packaged all-purpose boiler with optional equip ment:
1 G-26 DPG boiler with selt-energizing controls
1 222 tankless heater Mfd. gas. 550 Btu, .65 sg.
Notes:
For ordering instructions, see page 2. For optional equipment, see page 9. For complete information on boiler ratings, see
page 2. For discount on repairs, see page 2.
Page 6
This Price List has been prepared for the convenience of American-Standard distributors toners only The trade prices shown represent fixed markups over distributor prices to refle and distribution expense and do not purport to represent i.r.,,1 prices prevailing in an;
04647
A.merican"^tflnciard
HYDRONIC HEATING
boilers--gas fired STEAM and WATER
G-2 NON-PACKAGED ALL-PURPOSE American'Standard GAS BOILERS
Designed for water (forced or gravity) or steam. Flush or Deluxe jacket. Factory Assembled Sections. Sections tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air separator in left end section). Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2.000 feet.
WATER (Available with factory installed Tankless heater, see options, page 9.)
boiler number
A.CJL.
A.GA.
input MM
output Mbh
i
net i=B=R
Net., Mftf., Mixed end LP Gas; LP-Alr
rating Mbh
Gas 525-1400 Btu
net rating sq ft
water
Trade Price with standard equipment
less thermostat
flush jacket
deluxe jacket
chimney size
diameter inches
height feet
approx. shipping
weight
G-23*W
60 48 36
G-24-*W(T)
90
72
54
G-25-*W(T) 120 96 72
G-26*W(T) 150
120
90
G-27-*W(T) 180 144 108
G-28-*W(T) 210 168 126
240 360 480
600 720 840
$187.00 244.00 288.00
329.00 365.00 409.00
$201.00 258.00. 302.00
343.00 379.00 423.00
4 5 6
6 6 7
20 277 20 353 20 428
20 490 20 553 20 629
G 29-*W(T) G-210W(T) G-211-*W(T)
240 270 300
192 216 240
144 162 180
960 1080 1200
451.00 482.00 528.00
465.00 496.00 542.00
7 7 7
20 697 20 761 20 841
Substitute letter "P" for flush or "D" for deluxe jacket. Suffix "T" denotes forced circulation boiler equipped with factory installed tankless heater (see page 9 for added charge).
STEAM
boiler number
A.GJk. input Mbh
A.G.A. output
Mbh
Nat., Mfd.. Mixed and LP Gas: LP-Air
Gas 525-1400 Btu
net l=B=R rating
Mbh
sq ft
Trade Price with standard equipment
less thermostat
flush jacket
deluxe jacket
chimney size
ttiameter inches
height feet
approx. shipping
weight
G-23-S G 24--S G-25-'S
G-26--S G-27-S G-28-S
G-29*S G 210--S G-211'S
60 90 120
150 180 210
240 270 300
48 72 96
120 144 168
192 216 240
36 54 72
90 108 126
144 162 180
150 225 300
375 450 525
600 675 750
$224.00 281.00 325.00
366.00 402.00 446.00
488.00 519.00 563.00
$238.00 295.00 339.00
380.00 416.00 460.00
502.00 533.00 579.00
4 5 6
6 6 7
7 7 7
20 287 20 363 20 438
20 500 20 563 20 639
20 707 20 771 20 851
Substitute letter "FM for flush or "D" for deluxe jacket.
Standard equipment:
V-600 combination diaphragm gas valve furnished with all sizes Natural. Mixed, LP-Air, LP gas boilers and G-23 through G-27 Manufactured gas
boilers V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. V-532 diaphragm gas valve furnished for all gases for sizes not listed above with separate gas pressure regulator (except LP) and Baso switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); drain valve; draft hood; in sulated jacket; transformer.Draft hood shipped in separate carton for G-23-D,
For water boilers only: ASME relief valve; pressure and temperature gauge; CB-65653 immersion limit control.
For steam boilers only: Steam gauge; ASME safety valve; CB-450552 boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off; floor pan.
Ordering Examples:
1. Non-packaged all-purpose water boiler standard equipment and flush jacket:
1 G-27-FW boiler Nat. gas, 1000 Btu, .6 sg.
with
2. Non-packaged all-purpose steam boiler with op tional equipment and deluxe jacket: 1 G-210-0WT boiler with (1) No. 232 tankless heater installed Nal gas, 1000 Btu, .6 sg.
Notes: For ordering instructions, see page 2. For optional equipment, see page 9. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04648
Page 7
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling
jnd distribution expense and do not purport to represent actual pner- . .
rket
HH-4
BOILERS--GAS FIRED
WATfl AND STEAM
AMERiCAN-tStandard
HYDRONIC HEATING
G-2 NON-PACKAGED ALL-PURPOSE AMERICAN'<$tandard GAS BOILERS
HH-4
FOP. USE WITH "DW" FQUIPMFNT
DIRECT TYPE --Wafer boilers for hot water supply
Flush or Deluxe jacket. Hydrostatically tested at 200 lbs. Working pressure 80 lbs.
Not recommended for use in hard water areas. Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2,000 feet.
boiler number
G-23-*W G-24-*W G-25-*W
G-26-*W G-27-*W G-28-*W
G-29-*W G-210-*W G-211-*W
A.QJL input Mbh
A.GJL rating-gallons water per hour output
Mbh 60* rise 80* rise 100- rita
Nat., Mfd.. Mixtd and LP Gat; LP-Air Gat 525-1400 Btu
60 90 120
150 180 210
240 270 300
48 72 96
120 144 168
192 216 240
96 144 192
240 288 336
384 432 480
72 108 144
180 216 252
288 324 360
58 86 115
144 173 201
230 260 288
Trade Price
with "OW** equipment
flush Iacket
$201.00 258.00 302.00
343.00 379.00 423.00
465.00 496.00 542.00
deluxe Iacket
$215.00 272.00 316.00
357.00 393.00 437.00
479.00 510.00 556.00
approx. shipping weight
277 353 428
490 553 629 697 761 841
Substitute letter "F" for flush or "O" for deluxe jacket.
"DW" standard equipment:
In addition to boiler for water with "standard equipment" page 7, "DW" boilers are furnished with pressure gauge; 80 lb ASME relief valve instead of 30 lb. valve; im mersion operating control for use in storage tank; tank thermometer; name and rating plate for 80 lbs. working pressure.
Ordering tramples:
1. Non-packaged all-purpose water boiler with standard equipment and flush racket for hot water supply:
1 G-24-FW boiler with "DW" equipment Nat. gas, 1000 Btu, .6 sg.
2. Non-packaged all-purpose boiler with optional equipment and deluxe jacket for hot water supply: 1 G-25-DW boiler with "OW" equipment with manual opening feature on V-600 valve Nat. gas, 1000 Btu., .6 sg.
FOR USE WITH "IS" EQUIPMENT INDIRECT TYPE -- Steam boilers for hot water supply
Flush or Deluxe jacket.
boiler number
A.G.A. input Mbh
A.G.A. rating--gallons water per hour output
Mbh 60* rise 80* rite 100* rfse
Nat- Mfd.. Mixed and LP Gat: LP-Air Gat 525-1400 Btu
Trade Price
with MISM equiprnent
flush jacket
deluxe jacket -
approx. shipping
weight
G-23-*S G-24-*S G-25-*S
G-26-*S G-27-"S G-28-*S
G-29-*S G-210-*S G-211-"S
60 90 120
150 180 210
240 270 300
48 72 96
120 144 168
192 216 240
96 144 192
240 288 336
384 432 480
72 108 144
180 216 252
288 324 360
58 86 115
144 173 201
230 259 288
$234.00 291.00 335.00
376.00 412.00 456.00
498.00 529.00 575.00
$248.00 305.00 349.00
390.00 426.00 470.00
512.00 543.00 589.00
287 363 438
500 563 639
707 771 851
Substitute letter ''F" for flush or "D" tor deluxe jacket.
"IS" standard equipment:
In addition to boiler for steam with `'standard equipment" page 7, "IS" boilers are
furnished with immersion operating control for use in storage tank.
Ordering Examples:
2 Non-packaged all-purpose stea.n boiler with
l. Non-packaged all-purpose steam boiler with
optional equipment with flush jacket for hot
standard equipment with deluxe iacket for hot water supply:
1 G-26-DS boiler with "IS" equipment Nat. gas, 1000 Btu, .6 sg.
water supply: 1 G-24-FS boiler with "IS" equipment with runner type pilot ignition Nat. gas, 1000 Btu, .6 sg.
Notes:
for oraenng instructions, see page 2. For optional equipment, see page 9, For ompiele information on boiler ratings, see page 2. For discount on repairs, see page 2.
04649
Page 8
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent ae'.ual prices prevailing in any particular market.
American-^Standard
HYDRONIC HEATING
G-2 OPTIONAL EQUIPMENT
BOILERS--GAS FIRED STEAM AND WATER
ALL BOILERS Pages 5 thru 8:
Runner type pilot ignition for use with listed gases furnished at no charge when specified on order to meet local utility codes.
Push button electric ignition for use with listed gases. Not available with self-energizing controls. Specify on order and add SI 1.85 to Trade Price of boiler.
Floor shield for combustible flooring. Add suffix letter "C" to boiler number and add $3.00 to Trade Price of boiler.
Pilot filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes.
Manual opening feature on V-600 or V-532 gas valves fur nished at no additional charge when specified on order to meet local utility codes.
Zone valve packages are available for water boilers. For de tails and prices, see page 30.
PACKAGED GAS BOILERS Page 5 only: options listed above applicable only to these boilers.
PACKAGED ALL-PURPOSE BOILERS Page 6:
Tankless heaters: when boilers (4 thru 7 section! are to be used for forced circulation I=W=H tankless heaters can be installed in opening used for gravity tapping flange cover. See table below for I = W = H ratings and applicable boiler size Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below.
Self-energizing controls (consist of gas valve, pilot burner, limit control i for mfd.. natural and mixed gas. available when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 30.
Room thermostat prices shown on page 30.
ALL-PURPOSE BOILERS Page 7:
WATER BOILERS Factory installed tankless heaters: when boilers <4 thru 11 sec tion) are to be used for forced circulation I=W=H tankless heaters can be specified factory installed. See table below fol low =H ratings and applicable boiler size. Specify heater, add suffix "T" to boiler number and "factory installed" Trade Price shown below.
ALL-PURPOSE BOILERS Page 7:
WATER BOILERS (continued)
Tankless heaters: when boilers (4 thru 11 section) are to be used for forced circulation I=W=H tankless heaters can be installed in opening used for gravity tapping flange cover See table below for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below.
STEAM BOILERS
McDonnell-Miller No. 101-24V Electric Water Feeder can be added to the No. 67-G Low Water Cut-off furnished with G-2 All-Purpose Steam Boilers to provide Low Water Cut-off and Feeder Combination. If desired specify on order and add $37.07 to Trade Price of Steam Boiler.
Side Outlet ASME Safety Valve may be substituted at no additional charge if specified on order to meet local code requirements.
WATER OR STEAM BOILERS
Self-energizing controls (consist of gas valve, pilot burner, limit control, low water cut-off for steam boilers) for manu factured. natural and mixed gas. available when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 30.
Room thermostat prices shown on page 30.
Zone circulator control for water boiler with tankless heater and combination immersion control-relay: Use one CB-52502 thermostat and one relay for second and/or third zone. For Trade Prices, see page 30
Dual-gas boilers: available for both natural and propane gases. See below for added charges. Boiler prices on Page 7.
boiler no.
added charge
boiler no.
added charge
G-23 G-24 G-25 G-26 G-27
$50.00 52.00 54.00 56.00 58.00
G-28 G-29 G-210 G-211
$60.00 62.00 64.00 66.00
Equipment includes in addition to standard trim two V-532 gas valves, two manifolds with spuds factory assembled, outdoor changeover
control.
G-2 Tankless Heaters
Ratings
boiler number
G-24 G-25 G-26 G-27 G-28 G-29 G-210 G-211
A.G.A. Input Btu/hr.
90,000 120.000 150.000 180,000 210,000 240,000 270,000 300,000
heater 218
2`/z --
--
--
-- --
--
--
l=W=H Rating
heater 222
--
3
3%
3'/z 3'/z 3>/2 3`/z 3`/z
heater 226
--
--
4 4'/* 4% 4 Vi 4>/z
Gallons water per minute heated from 40*F to 140*F with 200'F boiler water temperature.
heater 232
-- -- -- -- --
4>/z 4 Vi
5
Trade Prices
heater number
factory installed
sold separate
218 $41.00 $19.00
222
43.00
21.00
226 51.00 29.00
232
55.00
33.00
Factory installed additional price includes comb'na tion immersion control-relay packed >n trim box
04650
Page 9
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling
and distribution expense and do not purport to :epiesent actual prices prevailing in
' ------- l"s'
HH-4
BOILERS-GAS FIRED
STEAM AND WATS*
AMERiCAN\$tandard
HYDRONIC HEATING
WATER
boiler number
G-403-W G-404-W G-405-W G-406-W G-407-W G-408-W G-409-W G-4010W
STEAM
boiler number
G-403S G-404-S G-405-S G-406-S G-407-S G-408-S G-409S G-4010-S
WATER
boiler number
G-403-W G-404W G-405-W G-406-W G-407-W G-408-W G-409-W G-4010W
STEAM
boiler number
G-403S G-404-S G-405-S G-406-S G-407-S G-408S G-409-S G-4010S
A.G.A.
Mbh
150 225 300 375 450 525 600 675
A.GJL input Mbh
150 225 300 375 450 525 600 675
A.GJL Input Mbh
120 180 240 300 360 420 480 540
A.G.A. Input Mbh
120 180 240 300 360 420 480 540
G-40 American-Standard GAS BOILERS
For Built-In Water Heater Arrangement, see page 11.
Deluxe jacket. Tested and equipped for 50 lbs. water working pressure. "Eliminaire" (cast-in air separator in left end section). Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2,000 feet.
for Natural, Manufactured, Mixed, Gas
A.GJL outout
Mbh
net l=B=R rating Mbh
net rating sq ft water
Trade Price with etendard
equipment
lese thermostat
120 180 240 300 360 420 480 540
90.0 135.0
180.0 225.1 270.1 315.1 360.1 405.1
600 900
1200 1500 1800 2100 2400 2700
$ 360.00 460.00 555.00 675.00 780.00 860.00 940.00
1045.00
chimn y size
dlam. In.
ht ft
6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20
approx. shipping
weight
827 998 1162 1349 1517 1686 1856 2026
A.GJL output
Mbh
120 180 240 300 360 420 480 540
A.GJL output
Mbh
96 144 192 240 288 336 384 432
net 1=8= 1 rating
Mbh
sq ft
Trade Price with standard
equipment less thermostat
90.0 135.0 180.0 225.1 270.1 315.1 360.1 405.1
375 563 750 938 1125 1313 1500 1688
$ 397.00 497.00 592.00 712.00 818.00 897.00 977.00
1082.00
for LP and LP-Air Gas
net l=B=R rating Mbh
net rating sq ft water
Trade Price with standard
equipment
less thermostat
72.0 108.0 144.0 180.0 216.1 252.1 288.1 324.1
480 720 960 1200 1440 1680 1920 2160
$ 360.00 460.00 555.00 675.00 780.00 860.00 940.00 1045.00
chimney size
diem. in.
ht ft
6 20 7 20 7 20 8 20
8 20 9 20 10 20 10 20
chimney size
diem. in.
ht ft
6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20
approx. shipping
weight
858 1027 1195 1370 1544 1713 1880 2050
approx. shipping
weight
827 998 1162 1349 1517 1686 1856 2026
A.G.A. output
Mbh
96 144 192 240 288 336 384 432
net l=B=R rating
Mbh
sq ft
72.0 108.0 144.0 180.0 216.1 252.1 288.1 324.1
300 450 600 750 900 1050 1200 1350
Trade Price with standard
equipment less thermostat
$ 397.00 497.00 592.00 712.00 818.00 897.00 977.00 1082.00
chimney sire
diem. In.
ht ft
6 20 7 20 7 20 8 20 8 20 9 20 10 20
10 20
approx. shipping
weight
858 1027 1195 1370 1544 1713 1880 2050
Standard equipment includes:
V-531 diaphragm gas valve with manual opening feature; Baso automatic pilot switch for non-100% shut-off (100% shut-off controls for LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves. Optional other gases at no additional charge); manual shut-off valve; pilot filter (manufactured gas and SUR); gas pressure regulator (except for LP gas); drain valves; pilot cocks; insulated jacket; draft hood; water heater opening cover plates.
For water boiler only: ASME relief valve for 50 lbs.; pressure and temperature gauge; CB-65653 immersion limit control.
For steam boiler only: Steam gauge; ASME safety valve; CB-450552 boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off.
Ordering Enmplei:
Notes:
1. Water boiler with standard equipment: 1 G-406-W boiler Nat. gas, 1000 Btu, .6 sg.
2. Steam boiler with optional equipment: 1 G-409-ST 1 No. 226 tankless heater with controls Nat. gas, 1000 Btu, .6 sg.
For ordering instructions, see page 2. For optional equipment, see page 11. For electronic control panel systems, see page IS.
For complete information on boiler ratings, see page 2.
For discount on repairs, see page 2.
HH-4
Page 10
This Price List has been prepared for the convenience of Amencan-'Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable : nnrl distribution evoeose and do not purport to represent actual prices prevailing in any particular rr
04651
AMERiCAN-tS>tandard
HYDRONIC HEATING
BOILERS-GAS FIRED
STEAM AND WATER
G-40 OPTIONAL EQUIPMENT
BOILERS WITH TANKLESS HEATERS: water (for forced circulation) and steam boilers can be furnished with tankless heaters. Heaters are limited to boiler sizes as shown m ratings table below. Specify heater and add suffix *T" to boiler number.
Tankless heaters with controls for water boilers: Combination immer sion control-relay packed m trim box in place of CB-6S6S3.
Tankless heaters with controls for steam boilers: additional immersion operating control packed m trim box.
If tankless heaters with controls are desired, specify on order with boiler and add to Trade Price of boiler with standard equipment the following charges.
Tankless heaters less controls will be furnished when specified at the Trade Prices shown below for heaters only.
HEATER M0.
218 222 226 232 445
HEATER WITH C0MTR01S
Water
Stain
$41.00 43.00 51.00 55 00 72.00
$29.00 31.00 39.00 43.00 60.00
HEATER ONLY
witrr r Stum
$19.00 21.00 29.00 33.00 50.00
Water flow regulators sized for tankless heater involved will be fur nished with heater when specified on order to meet local Utility require ment at $2.00 Trade Price additional charge per heater.
Factory assembled sections: G-403 through G-406 can be shipped with sections factory assembled when specified on order. If desired less tankless heater, add $15.00 to Trade Price of boiler. If desired with fac tory installed tankless heater, specify heater number, and add $15.00 plus price of heater to Trade Price of boiler.
Dual Gas Equipment: available with steam or water boilers for use with Natural and Propane gases only. In addition to standard trim, dual gas equipment includes tube within a tube manifold, two V-532 gas valves, gas pressure regulator (natural gas only), two manual shut-off valves, ribbon burners. 100% shut-off (consists of Baso combination pilot valve and switch with auxiliary Baso pilot valves), pilot cock, outdoor changeover control. Boiler selection should be based on the A G.A. and l=-B=R ratings shown for LP gas. If desired specify on order and add to Trade Price of boiler with standard trim the following charge:
Boiler Number
G-403 G-404 G-405 G-406
Add to Boiler Trade Price
$60.00 62.00 64.00 66.00
Boiler Number
G-407 G-40 8 G-40 9 G-4010
Add to Boiler Trade Price
$68.00 70.00 72.00 74.00
Electronic Control Systems: available with steam or water boilers. If desired refer to page 15 for complete details and additional Trade Price charges.
F.M. and F.I.A. equipment: requires EGO or EPG-0 electronic control system and special gas control equipment. Price on application.
Try-cock tappings and valves: if desired for steam boilers to meet code specify on order and add $4.00 to Trade Price of steam boiler.
Self-energizing controls: available for steam or water (gravity) less tankless heater for natural and mixed gases only. Equipment includes special gas valve, pilot burner, limit control: low water cut-off for steam boilers. Furnished at no additional charge when specified on order. Special room thermostat required, for Trade Price see page 30.
McDonncfl-Mlller No. 101-24 Volt Electric Water Feeder: can be added to No. 67-G low water cut-off furnished with G-40 Steam Boilers to provide low water cut-off and feeder combination. If desired specify on order and add $37.07 to Trade Price of steam boiler.
McOonneM-Milier No. 47-2 low water cut-off and feeder combination may be specified in place of regularly furnished No. 67-G for steam boilers. If desired specify on order and add $33.00 to Trade Price of steam boiler.
McOonnall-Miller No. 247-2 low water cut-off and feeder combination for water boilers is available with G-40 Water Gas Boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price of this item shown in the current McOonnell-Miller Price Sheet.
Runner type pilot Ignition: all sizes of G-40 are available with Runner type pilot ignition for natural, manufactured and mixed gas non-100% shut off at no additional charge when specified on order to meet local Utility codes.
Push button electric ignition: all sizes of G-40 are available with push button electric ignition for use with natural, manufactured and mixed gas non-100% shut-off and will be furnished when specified on order at $11.65 added charge.
Pilot filters for G-40 for natural and mixed gases available at no addi tional charge when specified on order to meet local utility codes.
Thermostats available at Trade Prices shown on Page 30
Zone circulator control for water boiler with tankless heater and com bmation immersion control-relay: Use one C8-52502 thermostat and one relay for second and/or third zone. For Trade Prices, see page 30.
"IS" Equipment: G-40 Gas Boilers can be furnished for use with In direct Steam Hot Water Supply systems. CB-65653 immersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on Page 30.
V-532 Diaphragm Gas Valve without manual opening may be substi tuted for V-531 Gas Valve with manual opening at no additional charge. If desired, specify on order.
Side Outlet ASME Steam Safety Valves may be substituted at no addi tional charge if specified on order to meet local code requirements.
Jacket Extension: covers ail controls on left end of boiler. If desired, specify on order and add $25.00 to Trade Price of Boiler. Approximate shipping weight 36 lbs.
G-40 Tankless Heater Ratings (Gallons per minute9)
Bolltr
G-403 G-404 6-405 G-406 G-407 G-408 G-406 G-4010
HEATER 211
Steam
Water
34
3Vi 4
3Vi 4 3V4 4 3V5z 4 3Vt 4
3 Vi 4
3V* 4
HEATER 222
Steam
_
4 4 4 4 4 4 4
Water
_
4Vz 4% 4Vt 4Vz 4Vi 4W 4Vj
HEATER 226
Steam
Water
_ --.
----
5Vt 6
6 6 6Vz
6 6Vz 6 6Vz
6 6Vt
HEATER 232
Steam
Water
----
---- ---- ---- 7 7Vi
7Vi 8 7Vi 8 7Vt 8
HEATER 445
Stum
Water
----
---- ---- ---- ---- 8Vi 9 8W 9 8V* 9
Gallons of wofer per minuft roiled from 4Q*F. fo I40*F.
04652
Page 11
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only. The trade prices shown represent fixed markups over distributor prices to reflect rsacAn-M- -elling
and distribution expense and do not purport to represent actual prir
.rket.
HH 4
boilers-gas fired
IT1AJM AMO WATI*
American-Standard
HYDRONIC HEATING
WATER
MUf number
G-606-W G-607-W G-608-W G-609-W G-6010-W G-6011-W G-6013W G-6G15-W G-6017-W
G-6019W G-6021-W G-6022-W G-6025-W G-6028W G6031-W G-6033-W G-6037-W G-6041-W
STEAM
boilar number
G-606-S G-607-S G-608-S G-609-S G-6010-S G-6011S G-6013S G-6015-S G-6017S G-6019-S G-6021-S G-6022-S G-6025-S G-6028S G-6031-S G-6033-S G-6037S G-6041S
A.QJL input
Mbh
725 870 1015 1160 1305 1450
1740 2030 2320
2610 2900 3045 3480 3915 4350
4640 5220 5800
A.G-A. input
Mbh
725 870 1015 1160 1305 1450 1740 2030 2320
2610 2900 3045 3480 3915 4350 4640 5220 5800
G-60 American-Standard GAS BOILERS
for Natural, Manufactured, Mixed Gas
Jacketed. Tested and equipped for SO lbs. water working pressure. Available for 80 lbs. working pressure on special order.
Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2,000 feet.
A.QJL output
Mbh
580 696 812
928 1044 1160
1392 1624 1856
2088 2320 2436
2784 3132 3480
3712 4176 4640
not l=B=R ratine Mbh
435.1 522.1 609.2
696.2 783.2 870.2
1054.5 1248.3 1438.8
1621.1 1801.2 1891.3
2161.5 2430.1 2701.9
2880.4 3245.3 3602.5
not ratine aq ft water
2900 3480 4060
4640 5220 5800
7030 8320 9590
10805 12010 12610
14410 16200 18010
19205 21635 24015
Trad# Prlca with ttandard
equipment Iota tharmostat
$ 961.00 1118.00 1283.00
1461.00 1638.00 1783.00
2092.00 2408.00 2711.00
3020.00 3329.00 3533.00
3967.00 4296.00 4895.00
5184.00 5803.00 6421.00
chlmnay alza
diam. In.
htft
ii 20 12 20 13 20
13 20 14 20 15 20
15 20 16 20 16 30
17 30 18 30 19 30
20 30 21 30 22 30
24 30 26 30 26 30
approx. hlppine
walcht
2741 3141 3527
3923 4335 4728
6049 6835 7620
8503 9292 10139
11334 12616 13809
15036 16690 18316
A.G.A. output
Mbh
net l=B =R ratine
Mbh
sq ft
Trada Price with standard
equipment lest thermostat
chlmnay alza
diam. in.
htft
approx. shippine
weight
580 696 812
928 1044 1160
1392 1624 1856
2088 2320 2436
2784 3132 3480
3712 4176 4640
435.1 522.1 609.2
696.2 783.2 870.2
1054.5 1248.3 1438.8
1621.1 1801.2 1891.3
2161.5 2430.1 2701.9
2880.4 3245.3 3602.5
1813 2176 2538
2901 3263 3626
4394 5201 5995
6755 7505 7880
9006 10126 11258
12002 13522 15010
$ 998.00 1155.00 1320.00
1498.00 1675.00 1820.00
2129.00 2445.00 2748.00
3057.00 3366.00 3570.00
4004.00 4333.00 4932.00
5221.00 5840.00 6458.00
u 20 12 20 13 20
13 20 14 20 15 20
15 20 16 20 16 30
17 30 18 30 19 30
20 30 21 30 22 30
24 30 26 30 26 30
2751 3151 3537
3934 4346 4739
6069 6855 7640
8523 9312 10154
11361 12648 13841
15068 16720 18346
Standard equipment includes:
V-531 diaphragm gas valve with manual opening feature; Baso automatic pilot switch for non-100% shut-off (100% shut-off controls consisting of Baso combination pilot switch and valve with auxiliary Baso pilot valves, optional at no additional charge); manual shut-off valve; pilot filter (manufactured gas and SUR); gas pressure regu lator; boiler drains and pilot cocks; insulated jacket; draft hood; transformer.
For water boiler only; ASME relief valve for 50 lbs.; pressure and temperature gauge; CB-65653 immersion
limit control.
For steam boiler only: Steam gauge; ASME safety valve; CB-450552 boiler pressure limit control; gauge glass
with trimmings; resetting low water cut-off.
Ordering Examples:
Notes:
1. Water boiler with standard equipment: 1 G-608-W boiler Nat. gas, 1000 Btu, .6 sg.
2. Steam boiler with optional equipment: 1 G-6011-S boiler with push button electric ignition Nat. gas, 1000 Btu, .6 sg.
For ordering instructions, see page 2. For optional equipment, see page 14.
For electronic control panel systems, see page 15.
For complete information on boiler ratings, see page 2.
For discount on repairs, see page 2.
HH-4
Pag. 12 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable sell .-r i.t:-hi,i,fin evnense and do not purport to represent actual prices prevailing In any particular marl
04653
American-^Standard
HYDRONIC HEATING
BOILERS--GAS FIRED
ITIAM AND WATIR
G-60 American-Standard GAS BOILERS
WATER
boiltr number
G-606-W G-607-W G-608-W
G-609-W G-6010-W G-6011-W
G-6013-W G-6015W G-6017W
G-6019W G-6021-W G6022-W
G-6025-W G-6028-W G-6031-W G-6033-W G-6037-W G6041-W
STEAM
boiler number
G-606-S G-607-S G-608-S
G-609-S G-6010-S G6011-S
G-6013-S G-6015-S G-6017-S G-6019-S G-6021-S G-6022-S
G-6025-S G-6028-S G-6031-S
G-6033-S G-6037S G6041-S
A.(LA. input Mbh
650 780 910
1040 1170 1300
1560 1820 2080
2340 2600 2730
3120 3510 3900
4160 4680 5200
A.(LA. input
Mbh
650 780 910
1040 1170 1300
1560 1820 2080
2340 2600 2730
3120 3510 3900
4160 4680 5200
for LP and LP-AIr Gas
Jacketed. Tested and equipped for 50 lbs. water working pressure. Available for BO lbs. working pressure on special order.
Controls regularly furnished for 115 volt, 60 cycle current. Ratings shown are for installation at sea level and up to 2,000 feet.
A.(LA. output
Mbh
520 624 728
832 936 1040
1248 1456 1664
1872 2080 2184
2496 2808 3120
3328 3744 4160
not l=B=R rating Mbh
390.1 468.1 546.1
624.2 702.2 780.2
936.2 1108.1 1282.0
1452.3 1614.9 1695.7
1937.9 2180.1 2422.4
2585.4 2903.7 3229.8
not rating q. ft. water
2600 3120 3640
4160 4680 5200
6240 7385 8545
9680 10765 11305
12920 14535 16150
17235 19360 21530
Trado Price with standard
equipment less thermostat
$ 961.00 1118.00 1283.00
1461.00 1638.00 1783.00
2092.00 2408 00 2711.00
3020.00 3329.00 3533.00
3967.00 4296.00 4895.00
5184.00 5803.00 6421.00
chimney size
diam. in.
ht ft.
ii 20 12 20 13 20
13 20 14 20 15 20
15 20 16 20 16 30
17 30 18 30 19 30
20 30 21 30 22 30
24 30 26 30 26 30
approi. shipping
weight
2741 3141 3527
3923 4335 4728
6049 6835 7620
8503 9292 10139
11334 12616 13809
15036 16690 18316
A.QJL output
Mbh
520 624 728
832 936 1040
1248 1456 1664
1872 2080 2184
2496 2808 3120
3328 3744 4160
net J=B=:R rating
Mbh
390.1 468.1 546.1
624.2 702.2 780.2
936.2 1108.1 1282.0
1452.3 1614.9 1695.7
1937.9 2180.1 2422.4
2585.4 2903.7 3229.8
sq. ft.
1625 1950 2276
2601 2926 3251
3901 4617 5342
6051 6729 7065
8075 9084 10093
10773 12099 13458
Trade Price with standard
equipment less thermostat
$ 998.00 1155.00 1320.00
1498.00 1675.00 1820.00
2129.00 2445.00 2748.00
3057.00 3366.00 3570.00
4004.00 4333.00 4932.00
5221.00 5840.00 6458.00
chimney size
diam. in.
ht. ft.
ii 20 12 20 13 20
13 20 14 20 15 20
15 20 16 20 16 30
17 30 18 30 19 30
20 30 21 30 22 30
24 30 26 30 26 30
approx. shipping
weight
2751 3151 3537
3934 4346 4739
6069 6855 7640
8523 9312 10154
11361 12648 13841
15068 16720 18346
Standard equipment includes:
V-531 diaphragm gas valve with manual opening; 100% shut-off (100% shut-off controls for LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves); manual shut-off valve; gas pressure regulator (except for LP-gas); drain valves; pilot cocks; insulated jacket; draft hood; transformer.
For water boiler only; ASME relief valve for 50 lbs ; pressure and temperature gauge; CB-65653 immersion limit
control.
For steam boiler only: Steam gauge; ASME safety valve; CB-450552 boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off.
Ordering Eiamples:
Notes:
1. Water boiler with optional equipment:
For ordering instructions, see page 2.
1 G-6013-W boiler with dual gas equipment Propane gas.
For optional equipment, see page 14. For electronic control panel systems, see page 15.
2. Steam boiler with standard equipment:
1 G-6015-S boiler Butane gas
For complete information on boiler ratings, see page 2.
For discount on repairs, see page 2.
Page 13
This Price List has been prepared for the convenience ot American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing m any particular nurta*
04654
HH-4
BOILERS--GAS FIRED
STEAM AND WATKt
American-^Standard
HYDRONIC HEATING
G-60 OPTIONAL EQUIPMENT
Push button electric ignition: all sizes of G-60 are available with push button electric ignitiom for use with natural, manu factured and mixed gas non-100% shut-olT, and will be fur nished when specified on order at the following added charges:
bollar size
added charge
G-606 thru G-6011
$11.85
G-6013 thru G-6021
23.70
G-6022 thru G-6031
35.55
G-6033 thru G-6041
47.40
Pilot filters for G-60 for natural and mixed gases available at no additional charge when specified on order to meet local
utility codes.
Room thermostats available at Trade Prices shown on page 30.
McDonnell-Miller Low Water Cut-off No. 67 external type can be substituted for the regular No. 69 Low Water Cut-off on G-60 steam gas boilers at no additional charge. If desired, specify on order.
"IS" Equipment: G-60 gas boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. CB-65653 im mersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on page 30. This control operates gas valves on boiler electrically as required. Shipping weights of gas boilers for hot water supply are same as shown for regular gas boilers.
Try-cock tappings and valve: if desired for steam boiler to meet local code specify on order and add $4.00 to Trade Price of steam boiler.
G-60 available tested for 80 lbs. water working pressure when specified on order. Add $3.00 per section to Trade Price of
water boiler.
McDonnell-Miller No. 47-2 and 51-2 Low Water Cut-off and Feeder combinations are available with G-60 steam gas boil ers in place of regularly furnished No. 69 low water cut-off. when specified on order, at the following added charges to Trade Price of steam boilers with regular equipment:
boiler number
G-606 thru G-6011
G-6013 thru G-6041
combination number
47-2
51 2
added chargee
$38.00
54.00
McDonnell-Miller No. 247-2 and 51-2 low water Cut-off and Feeder combinations for water boilers are available with G-60 water gas boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade p- . for these items shown in the current McDonnell-
Miller ; , e sheet.
F.M. and F.I.A. equipment: requires EG-0 or EPG-0 electronic control system and special gas control equipment. Price on application.
V-532 Diaphragm gas valve without manual opening may be substituted for V-531 Gas valve with manual opening at no additional charge If desired specify on order.
Side Outlet Steam ASME Safety Valves may be substituted at no additional charge if specified on order to meet local code requirements.
G-60 external water heater tappings: maximum size all sec tions 1 V<". Add to Trade Price of boiler $2.00 per section tap ping and $2.00 per jacket punching.
G-60 Right end steam trim tappings for pressure gauge and water column gauge glass furnished when specified on order
at Trade Price additional charge of $10.00 per boiler.
G-60 DUAL GAS BOILERS Natural and Propane Gases
G-60 steam or water boilers are available with dual gas equipment using natural and propane gases. Specify on order and add the charge shown below to boiler with standard equipment. Selection of the boiler should be based on the A.G.A. and I=B=R ratings shown on page 12.
04655
boiler number
add to boiler Trade Price
boiler number
add to boiler Trade Price
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017
$ 95.00 100.00 105.00 110.00 115.00 120.00 145.00 165.00 185.00
G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041
$205.00 225.00 240.00 270.00 300.00 350.00 375.00 445.00 480.00
Dual gas equipment:
In addition to boiler with standard trim, dual gas boilers include:
Two V-532 diaphragm gas valves; two manifolds; gas pres
sure regulator (natural gas only); manual shut-off valves; ribbon burners; 100% safety shut-off (consists of Baso com bination pilot switch and valve with auxiliary Baso pilot valves); pilot cock; outdoor change-over control.
hh-4
Page 14
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent ac'ual prices prevailing in any partic
American-Standard
HYDRONIC HEATING
BOILERS-GAS FIRED
STEAM AND WATER
G-40 AND G-60 ELECTRONIC CONTROL PANEL SYSTEMS
Panel System EPG-O: Provides electronic supervision of each primary pilot in each combustion chamber (1 to 4) and inter mittent c.cctr:c ijr.itior. o- a.- pi.cts. Complete automatic op eration of boiler. 100% safety shut-ofT. Equipment includes: one main control panel with 1 to 3 auxiliary panels pre-wired and factory assembled; Q179A flame rod and electric ignition pilots: ignition transformer; V495B pilot solenoid valves; RA890E electronic relay for each panel with 2-4 seconds re sponse timing and alarm contacts: minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot, as required. See additional charges below.
Panel System EPG-1: Provides manual ignition, non-100% shut-off. Available for Natural. Manufactured and Mixed Gas only. Electronic supervision of a primary pilot and thermo couple supervision of all auxiliary pilots. Main burner gas supply only turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel: Q179B flame rod primary pilot(s); Baso auxiliary pilot burners; Baso 850-1 switches with ther mocouples; RA890E electronic relay fur each panel with 2-4 seconds response timing and alarm contacts; minimum of 3 ft. of flame rod wire per pilot, as required. See additional charges below.
Panel System EPG-2: Provides manual ignition, 100% shut off. Available for all gases. Electronic supervision of a pri
mary pilot and thermocouple supervision of all auxiliary pilots. Main burner and pilot burner gas supply turned off on pilot failure Continuous flame pilot operation. E-ui-m.cnt includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q179B flame rod primary pilot <s> with special adapter for thermocouple; Baso auxiliary pilot burners: Baso 817-F-ll pilot valves with thermocouples; RA890E electronic relay for each panel with 2-4 seconds response timing and alarm con tacts; minimum of 3 ft. of flame rod wire per pilot, as required. See additional charges below.
Panel System EPG-3: Provides intermittent electric ignition on a primary pilot and continuous flame auxiliary pilots with 100% shut-off. Available for all gases. Electronic supervision of a primary pilot and thermocouple supervision of auxiliary pilots. Main burner and pilot burner gas supply shut-off on pilot failure. Equipment includes: one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel; Q179A flame rod and electric ignition primary pilot(s); primary pilot solenoid valve(s) V495B; Baso auxiliary pilot burner; Baso 817-F-ll pilot valves with thermocouples; 6000 volt secondary ignition trans former (s); RA890E electronic relay for each panel with 2-4 seconds response timing and alarm contacts: minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot, as re quired. See additional charges below.
ADDITIONAL CHARGES--Trade Price
Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment.
Ordering Example: 1 G-404-S boiler with EPG-0 System nat. gas. 1000 8tu .6sg.
Panel System EPG-0
boiler number
added charge
Panel System EPG-1
boiler number
added charge
Panel System EPG-2
boiler number
added charge
G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G-6013 thru 6021 G-6022 thru 6031 G-6033 thru 6041
$166.00 182.00 182.00 369.00 553.00 738.00
G- 403 thru 4010 $151.00
G- 606 thru 6037
151.00
G-6041
282.00
Mfd. gas only:
G 6028 thru 6037 $283.00
G- 403 thru 4010 $172.00
G- 606 thru 6037
172.00
G-6041
284.00
Mfd. gas only;
G-6028 thru 6037 $285.00
Panel System EPG-3
boiler number
charge
G- 403 thru 4010 $188.00
G- 606 thru 6037
188.00
G-6041
337.00
Mfd. gas only:
G-6028 thru 6037 $340.00
Panel System EPG-1 available for Natui.il M.wiufoctu-ed and Mined gases only. Balance for all gases.
G-40 AND G-60 ELECTRONIC CONTROL SYSTEMS (less Panels)
The following systems (EG-0. EG-l. EG-2 and EG-3) are also available. but do not include factory wired and assembled control panel. These systems provide the same function and
are equipped with the same basic parts (less panel) as described for EPG-0, EPG-1. EPG-2. and EPG-3.
System EG-O: System EG*1: System EG-2: System EG-3:
(Samefunction as EPG-0 less panel.) See additional charges below. (Samefunction as EPG-l loss panel.) See additional charges below. (Samefunction as EPG-2 less panel.) See additional charges below. (Samefunction as EPG-3 less panel.) See additional charges below.
04656
ADDITIONAL CHARGES-Trade Price
Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment.
Ordering Example: 1 G-6015-W boiler with EG-1 System mfd. gas, 550 Btu 65sg.
Control System EG-0
boiler number
added charge
Control System EG-l
boiler number
added charge
Control System EG-2
boiler number
added charge
Control System EG-3
boiler number
added charge
G- 403 thru 407 G- 408 thru 4010
G- 606 thru 6011 G-6013 thru 6021 G 6022 thru 6031 G-6033 thru 6041
$111.00 145.00
145.00 290.00 435.00 580.00
G- 403 thru 4010 $ 87.00
G- 606 thru 6037
87.00
G-6041
174.00
Mfd. gas only:
G 6028 thru 6037 $175.00
G- 403 thru 4010 $ 97.00
G- 606 thru 6037
97.00
G-6041
176.00
Mfd. gas only:
G-6028 thru 6037 $177.00
G- 403 thru 4010 $116.00
G- 606 thru 6037
116.00
G-6041
230.00
Mfd. gas only:
G-6028 thru 6037 $233.00
Control System EG-l available for Natural. Manufactured and Mixed gases only Balance for alt gases.
Ignition Cable: Trade Price per foot Flame rod wire: Trade Price per foot
........................................................... $0.70 ................................................................................ $0.30
Page 1 5
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense .inti do not purport to represent actual prices prevailing in any particular market
HH-4
PACKAGED BOILER-BURNER UNITS
w*m
AMERiCAN-^ltandard
HYDRONIC HEATING
APR PACKAGED BOILER-BURNER UNITS
Designed and equipped with controls for forced circulation. Factory assembled with jacket and crated. Built-in air-separator in top section. Motors and controls regularly furnished for 115 volt, 60 cycle current.
WATER
packaged
unit number
gross
lsB = R output
Mbh
IsBsR burner capacity
gph
net IsBsR
rating Mbh
net rating
sq ft water
Trade
Price with standard equipment
APR-72 APR-90
72 0.70 54.0 360 90 0.90 67.5 450
$300.00 325.00
Nozzle sizes 60* solid, gph, furnished with APR packaged units: APR-72. 0.75: APR-90. 0.85.
chimney size
8 x 8 x 15 8x8x 15
approx. shipping weight
306 344
HH-4
Standard equipment all Units:
Model DH-5 Arcoflame oil burner with sling mounting and factory installed light sensing flame detector. Constant ignition light sensing primary control. Unitized ceramic fiber refractory combustion chamber. Draft regulator. ASME relief valve. 1" circulator. Wiring harness and junction box. Drain valve. Pressure and temperature gauge. CB-58000 thermostat. AY-553 and AY-686 limit controls with Hi-Lo selector switch. Two-stage fuel unit available at $5.00 Trade Price extra.
Note: APR units are shipped with jacket and electrical controls (except thermostat), com bustion chamber, circulator, factory assembled and wired. Arcoflame oil burner shipped separately. Draft regulator, relief valve and thermostat.are secured inside boiler box.
Zone valve packages are available for APR units. For details and prices, see page 30.
Ordering Example: Packaged unit with standard equipment: 1 APR-90
Hotel: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04657
Page 16
This Price List has been prepared for the convenience of American-Standard distributors and their trade eus* lomersonly The trade prices shown represent fixed markups over distributor prices to reflect reasonable sellin
nvnonco > n H rl <-> nnl h'l'nne* <n e.nt,,,,,,,, a r- < > I P'TPc DrevailinE m 3nV DartlCUlaT marke'
AMERiCAN'<tandard
HYDRONIC HEATING
PACKAGED BOILER-BURNER UNITS
WATIR
APH PACKAGED BOILER-BURNER UNITS
Designed and equipped with controls for forced circulation. Factory assembled and crated. Square jacket. Built-in air-separator in top section. Motors and controls regularly furnished for 115 volt, 60 cycle current.
WATER
packsfad
unit number
frost l=B=R
output Mbh
I=B=R burner caps city
CP*
nst l=B=R
rating
Mbh
nt rating
SR ft
water
Trade Price with
standard
equipment
chimney size
APH-115 115 1.15
86 575 $350.00
APH-150 150 1.45 113 750
410.00
APH-185 185 1.80 139 925
470.00
8x8x 15 8x8 x 15 8x8x 15
'Nozzle sizes, gph, 60* solid, furnished with APH packaged units: APH-115. 1.10; APH-150. 1.35; APH-185. 1.75.
approx. shipping
walght
330 375 420
Standard equipment all Units:
Model DH-5 Arcoflame oil burner with sling mounting and factory installed light sensing flame detector. Constant ignition light sensing primary control. Unitized ceramic fiber refractory combustion chamber.
Draft regulator. ASME relief valve. 1 Vi' circulator. Wiring harness and junction box. Pressure and temperature gauge. Drain valve. CB-52502 thermostat. AY-553 and AY-686 limit controls with HI-LO limit selector switch. Two-stage fuel unit is available at $5.00 Trade Price extra. Note: APH units are shipped with jacket and electrical controls (except thermostat), com bustion chamber, circulator, factory assembled and wired. Oil burner shipped separately. Draft regulator, relief valve and thermostat are secured inside boiler crate.
Zone valve packages are available for APH units. For details and prices, see page 30.
Ordering Example:
Packaged unit with standard equipment:
1 APH-115 Notes:
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04658
Page 17
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing ur any particular market.
HH-4
Americaat -<St andard
HYDRONIC HEATING
BOILER-BURNER UNITS
STEAM AND WATH
A-3 NON-PACKAGED ALL-PURPOSE BOILER-BURNER UNITS
Equipped with controls for water (forced or gravity circulation) or steam. Factory assembled sections. iir.i w_ - .. .* a * *> -
Flush jacket. Motors and controls regularly furnished for 115 volt, 60 cycle current.
WATER
boiler-
burner unit
number
gross J=B=R
output Mob
l=B = R burner capacity
fph
tankless heater number
A l=W=H
rating
net l=B=R
rating
Mbh
net rating
sq ft water
Trade Price
with standard
equipment
chimney size
approx. shipping
weight
Forced circu ation units with fa ctory inst ailed tankless heater With Rfi 182A Aquastat relay combination, high limit, low lim it and circulator cor trol. light sensing c onstant ignition cont rol.
A-33WBT A-34WBT A-35-WBT A-36WBT A-37WBT
100 136
173 208 244
0.95 1.35 1.70 2.00 2.30
222 230 328 335 335
4 4
4 V* 5 Vi 5 V.
75.0 102.0 129.8 156.0 183.0
500 680
865 1040 1220
$378.50 448.50 530.50 600.50 676.50
8 x 8 x 15 8x8*15
8x8x 15 8x8x 15 8 x12 x15
666 751 878 1016 1148
Forced circulation units less heater: With R8182C Aquastat combination, limit and circulator control, light sensing constant ignition primary control.
A-33-WB A-34-WB A-35-WB A-36-WB A-37-WB
100 136 173 208 244
0.95 1.35 1.70 2.00 2.30
Gravity units less heater With ignition primary control.
75.0 102.0 129.8 156.0 183.0
500 680 865 1040 1220
$351.50 420,50 497.50
561.50 637.50
8 x 8 x 15 8 x 8 x 15 8x8x 15 8 x 8x 15 8 x 12 x 15
655 737
872 1002 1135
L4080 Aquastat limit control, and separate R8184A light sensing constant
A-33WBG A-34-WBG
A-35WBG A-36WBG A-37-WBG
100 136 173 208 244
0.95 1.35
1.70 2.00 2.30
75.0 102.0 129.8 156.0 183.0
500 680 865 1040 1220
$347.00 416.00
493.00 557.00 633.00
8 x 8 x 15 8x8x 15 8x8x 15
8 x 8 x 15 8 x 12 x15
660 742 877 1006 1138
STEAM
boilerburner
unit number
gross l=B = R
output
Mbh
l=B=R burner capacity
gph
tankless
heater number
A l=W=H rating
net l=B = R rating
Mbh
net l = B=R
sq ft steam
Trade Price with
standard
equipment
chimney size
approx. shipping
weight
Steam units with factory installed tankless heater: With PA404A Pressuretrol, L4006A Aquastat operating control, and separate R8184A light sensing constant ignition primary control.
A-33-SBT A-34-SBT A-35-SBT A-36SBT A-37-SBT
100 136 173 208 244
0.95 1.35 1.70 2.00 2.30
222 230 328 335 335
3`/2 3*/2 4% 4 Vi 5V,
75.0 102.0 129.8 156.0 183.0
313 425 541
650 763
$375.00 446.00 528.00 598.00 674.00
8x8x 15 8x8x15 8 x 8 x 15 8 x 8 x 15 8 x 12 x 15
666 751 878 1016 1148
Steam units less heater: With PA404A Pressuretrol, and separate R8184A light sensing constant ignition primary control.
A-33SB A-34-SB A-35-SB A-36-SB A-37-SB
100 136 173 208 244
0.95 1.35 1.70 2.00 2.30
75.0 102.0 129.8 156.0 183.0
313 425 541
650 763
$347.00 416.00 493.00 557.00 633.00
Nozzle sizes, gph, 60* furnished with A-3 boiler-burner units:
A-33-B, 0,90--H; A-34-B. 1.25-H; A-35-B, 1.50--S: A-36-B. 1.75--S: A-37-B, 2.25-S. AGallons of water per minute heated from 40F to 140F with 200F boiler water temperature.
8x8x 15 8 x 8 x 15 8x8x 15 8 x 8 x 15 8 x 12 x15
661 743 878 1007 1139
04660
Standard equipment:
Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. CB-52502 thermo stat. Nozzle. Draft regulator. High tem perature steel combustion chamber. Drain valve.
For units WITH water heater, 1 cover plate with control tapping.
For units LESS water heater, 2 cover plates for heater openings.
Water: Pressure and temperature gauge. ASME relief valve.
Steam: Steam gauge. ASME safety valve. Gauge glass and trimmings.
Ordering Examples:
1. All-Purpose boiler-burner unit with standard equip ment.
For lorced circulation, with heater-. I A-37-W9T botler-burner unit
For gravity circulation: 1 A-33-WBG boiler-burner unit
2. All-Purpose boiler-burner unit with optional equip ment:
For forced circulation, less heater: 1 A-35-W8 boiler-burner unit with two-stage
Notes:
fuel unit
For optional equipment, see page 21. for complete information on boiler ratings, see page 2.
For discount on repairs, see page 2.
Page 19
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing m any particular market.
HH-4
OIL FIRED BOILERS
ST1AM AND WATtt
American-^Standard
HYDRONIC HEATING
A-3 ALL-PURPOSE OIL FIRED BOILERS
For water (forced or gravity circulation) or steam. Factory assembled sections. Wet base construction. Flush jacket
WATER
botfGT number
iron l=B=R
output Mbh
IssBaR burner
capacity
IP*
tankfeea haatar
number
l=W=H rating
net l=Bs;R
ratine Mbh
Boiler with factory installed tankless heater--forced circulation
net ratine
aq ft watar
A-33-WT A-34-WT A-35-WT A-36-WT A-37-WT
100 136 173 208 244
0.95 1.35 1.70 2.00 2.30
222 230 328 335 335
4 4 43/,
5*/2 5Va
75.0 102.0 129.8 156.0 183.0
500 680 865 1040 1220
Boiler less heater--gravity or forced circulation
A-33-W A-34-W A-35-W A-36-W A-37-W
100 136 173 208 244
0.95 1.35 1.70 2.00 2.30
75.0 102.0 129.8 156.0 183.0
500 680 865 1040 1220
Trade Rhea
$250.00 321.00 403.00 473.00 549.00
$232.00 301.00 378.00 442.00 518.00
chimney size
approx. ahlppine weight
8x8x 15 8x8x15 8x8x 15 8x8x 15 8x 12 x 15
613 698 825 962 1093
8x 8x 15 8x8x 15 8x8x 15 8x8x 15 8x 12 x15
605 687 822 951 1083
STEAM
boilar number
croas 1=B=R
output Mbh
IsBsR burner capacity
SPb
tank!esc haatar number
A tsW=H ratine
Boiler with factory installed tankless heater
net l=B=R
ratine Mbh
net l=8=R
aq ft ateam
Trade Price
chimney size
A-33-ST A-34-ST A-35-ST A-36-ST A-37-ST
100 136 173 208 244
0.95 1.35 1.70 2.00 2.30
222 230 328 335 335
3`/2 3 Vi 4/
43/ 5>/
75.0 102.0 129.8 156.0 183.0
313 425 541 650 763
$250.00 321.00 403.00 473.00 549.00
8x8x 15 8x8x 15 8x8x15 8x 8x 15 8x 12 x 15
Boiler less heater
A-33-S A-34-S A-35-S A-36-S A-37-S
100 136 173 208 244
0.95 1.35 1.70 2.00 2.30
75.0 102.0 129.8 156.0 183.0
313 425 541 650 763
$232.00 301.00 378.00 442.00 518.00
8x8x 15 8x8x 15 8x8x 15 8x8x 15 8x 12 x 15
^Gallons of water par minuta haatad from 40F to 140F with 2OOF boilar watar temparatura.
approx. shipping weight
614 699 826 963 1094
606 688 823 952 1084
HH-4
Standard equipment all boilers:
High temperature steel combustion cham ber. Drain valve.
Water Pressure and temperature gauge, ASME relief valve.
Steam: Steam gauge. ASME safety valve, gauge glass and trimmings.
Note: Boilers with factory installed tankless heater are shipped with one water heater opening cover plate with Vi" control tap ping. Boilers less factory installed heater are shipped with an additional water heater opening cover plate (blank).
Ordering Examples:
1. Water boiler less heater with standard equioment: 1 A-34-W boiler
2. Steam boiler with heater with standard equipment: 1 A-36-ST boiler
3. Water boiler with heater with optional equipment: 1 A-35-WT boiler with jacket extension
Notes:
For optional equipment, see page 21. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Pag* 20
This Price List has been prepared tor the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable and distribution expense and do not purport to represent actual prices prevailing in any particular
04661
American-Standard
HVDRONIC HEATING
BOILER-BURNER UNITS OIL FIRED BOILERS
STfAM AHO WATER
A-3 OPTIONAL EQUIPMENT
FOR PACKAGED AND ALL-PURPOSE BOILER-BURNER UNITS AND OIL FIRED BOILERS:
Jacket extension: Specify on order and add $28.00 to Trade Price of boiler or unit. Jacket extension provides 15%" in front for concealment of oil burner and controls; approximate shipping weight 35 lbs.
FOR PACKAGED AND ALL-PURPOSE BOILER-BURNER UNITS:
Two-stage fuel unit will be furnished on order at $5.00 Trade Price extra.
For substitution of No. 4 control set consisting of CB-52502 thermostat, L4062B Aquastat limit and circulator control, plus a No. R8184A light sensing constant ignition primary control, instead of R8182C combination control, add to price of nonpackaged A-3 boiler-burner units for forced circulation LESS heater $2.50 Trade Price extra.
For substitution of No. 5 control set consisting of CB-52502 thermostat, L8024A Aquastat, limit, reverse and operating control, circulator relay, plus a No. R8184A light sensing constant ignition primary control, instead of R8182A com bination control, add to price of non-packaged A-3 boilerburner units for forced circulation WITH tankless heater $2.50 Trade Price extra.
Order add-on No. 5-Z control set at $19.35 Trade Price extra
for use with A-3 packaged or all-purpose non-packaged boiler-burner units with tankless heater.
Order R8182A Aquastat-relay combination at $10.00 Trade Price extra instead of R8182C control to permit use of tankless heater with A-3 non-packaged boiler-burner units furnished less water heater.
Controls and Arcoflame control sets are shown on page 30. McDonnell-Miller No. 67 low water cut-off with quick hook up fittings is available at current price for A-3 steam units and boilers.
Zone valve packages are available for water units and boilers. For details and prices, see page 30.
BUILT-IN TANKLESS HEATERS:
Built-in tankless heaters can be ordered for separate shipment with packaged and all-purpose boiler-burner units and oil fired boilers less factory installed heaters at the following Trade Prices:
Heater number
222 230 328 335
Trade Price
$21.00
23.00 28.00 34.00
NOTE: For |=W=H ratings and boilers or units with which heaters can be used, see table below.
I=W = H RATED TANKLESS WATER HEATERS FOR A-3:
Heaters tested with boilers.
Built-in tankless heaters for boiler-burner units and oil boilers can be ordered for separate shipment with units or boilers specified less tankless heaters at Trade Prices shown above. Select heater from table below.
unit or
boiler
site
l=B=R burner capacity
gph
heater number
A l=W::H rating
water
steam
A-33 A-34 A-35 A-36 A-37
0.95 1.35 1.70 2.00 2.30
222 230 328 335 335
4 4 4% 5/2 5%
3`/2 3`/2 4 Vi 4% 5 Vi
A Gallons of water per minute heated from 40F to 14QF with 200F boiler water temperature.
04662
Page 21
This Price List has been prepared lor the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevalii**"*
HH4
BOILER-BURNER*7 UNITS OIL FIRED BOILERS
fTSASI AND WATIk
'AmericanStandard
HYD R O N I C t H E ATI NO
SEVERN BOILER-BURNER UNITS
Flush jacket. Motor* and control* regularly furnished for 115 volt, 60 cycle current.
boller-bumar unit number
STEAM
WATER
Cross output
Mbh
firing rats ____ Bh_____
installed radiation
sq ft staam
Mbh
NOT TAPPED FOR BUILT-IN TANK TYPE WATER HEATER (see options)
c ft watar
----------17535--------Plica with standard equipment
approx. hipping
weight
S-17-OB S-21-OB S-25-OB
S-29-OB S-33-OB S-37-OB
W-17-OB
146
1.5
456
109.5
730
$489.00
1283
W-21-OB
168
1.7
525
126.0
840
531.00
1438
W-25-OB
188
1.9
588
141.0
940
572.00
1550
W-29-OB
216
2.2
675
162.0
1080
615.00
1690
W-33-OB
247
2.5
772
185.3
1235
680.00
1795
W-37-OB
278
2.8
869
208.6
1390
738.00
1955
ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER
S-17-OB-T
W-17-OB-T
146
1.5
456
109.5
730
$495.00
1292
S-21-OB-T
W-21-OB-T
168
1.7
525
126.0
840
537.00
1447
S-25-OB-T
W-25-OB-T
188
1.9
588
141.0
940
578.00
1559
S-29-OB-T
W-29-OB-T
216
2.2
675
162.0
1080
621.00
1699
S-33-OB-T
W-33-OB-T
247
2.5
772 185.3 1235
686.00
1804
S-37-OB-T
W-37-OB-T
278
2.8
869
208.6
1390
744.00
1964
*Nozzl sizes, gph 60* Solid, furnished with Severn boiler-burner units: No. 17, 1.35; No. 21. 1.50; No. 25. 1.75; No. 29. 2.00; No. 33. 2.25; No. 37. 2.50.
Standard equipment:
Model DH-6 Arcoflame oil burner with factory installed light sensing flame detector with sling mounting.
Constant ignition light sensing primary control. Draft regulator.
Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omis sion listed on page 23.
For steam--No. 1 control set: CB-52502 thermostat, PA404A Pressuretrol, nozzle. Steam gauge. ASME safety valve. Gauge glass and trimmings.
For water-No. 3 control set: CB-52502 thermostat, L4080 Aquastat limit control, nozzle. Pressure and temperature gauge. ASME relief valve.
SEVERN OIL FIRED BOILERS
Flush jacket.
04663
boilar-oumbar
STEAM
WATER
gross output
Mbh
firing rata
fph
Installed radiation
sq ft staam
Mbh
sq ft watar
NOT TAPPED FOR BUILT-IN TANK TYPE WATER HEATER (see options)
S-17-0 S-21-0 S-25-0
S-29-0 S-33-0 S-37-0
W-17-0 W-21-0 W-25-0
W-29-0 W-33-0 W-37-0
146
1.5
456
109.5
730
168 1.7 525 126.0 840
188
1.9
588
141.0
940
216
2.2
675
162.0
1080
247 2.5 772 185.3 1235
278
2.8
869
208.6
1390
ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER
S-17-0-T S-21-0-T S-25-0-T
S-29-0-T S-33-0-T S-37-0-T
W-17-0 T
146
1.5
456
109.5
730
W-21-0-T
168
1,7
525 126.0
840
W-25-0-T
188
1.9
588
141.0
940
W-29-0-T
216
2.2
675
162.0
1080
W-33-0-T
247
2.5
772
185.3
1235
W-37-0-T
278
2.8
869
208.6
1390
Trade Price with standard equipment
$355.00 397.00 436.00 479.00 542.00 600.00
$361.00 403.00 442.00 485.00 548.00 606.00
approx. shipping weight
1075 1230 1325 1465 1560 1720
1064 1239 1334 1474 1569 1729
Standard equipment:
For Steam only: Steam gauge. ASME safety valve. Gauge glass and trimmings.
For Water only: Pressure and temperature gauge. ASME re lief valve.
Notts: For optional equipment, see page 23.
For complete information on boiler ratings, see page 2.
For discount on repairs, see page 2.
Ordering Examples:
1. Boiler-Burner Unit for steam not tapped for heater with standard equipment: 1 S-25-0B boiler-burner
2. Boiler-Burner Unit for water arranged for but less heater with optional equipment: 1 W-33-OB-T boiler-burner with two-stage fuel unit.
, 3. Boiler only for water arranged for but less heater with optional equip ment: 1 W-21-0-T boiler with heater opening cover plate
HH-4
Page 22
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable sellins and distribution expense and do not purport to represent actual prices prevailing In any particular it
AMERiCAN-<$tandard
H YDRONIC HEATING
BOILER-BURNER UNITS OIL FIRED BOILERS
STUM AND WATS*
SEVERN OPTIONAL EQUIPMENT
BOILER-BURNER UNITS only:
Arcoflame control sets other than those included in Trade Price of boiler-burner units will be furnished when specified on order at the following added charges:
Control Sat
Added Charge
Steam control set No.2................................... $10.00
Water control set No.4..................................
5.80
Water control set No.6................................... 24.30
Water control set No.7................................... 22.45
Controls and Arcoflame control sets are shown on page 30.
Two-stage fuel unit is available for DH-6 oil burner at added Trade Price charge of..................................................................$5.00
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Zone valve packages are available for water boilers. For de tails and prices, see page 30.
For low water cut-off for use with steam units, see page 30.
Molded refractory combustion chambers for Severn boilers: Trade Prices are same as "Deduct for Omission" prices shown below.
Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70.
BUILT-IN HEATERS:
If 2V2" right or left side tapping in back section for built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of unit or boiler.
Below are the ratings and Trade Prices covering built-in tank or tankless heaters available for Severn units. For detailed information on ratings, see page 2.
Haater No.
703 594 595 590
Heater Type
Heatar^a tings Sait, capacity
tank tank tank tankless
66 100 160 3i/2 per minute
Trade Price
$ 9.00 48.00 42.50 36.00
approx. shipping weight
7 54
51
60
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit number
Heat Ub-O-Rator model No. Included
maximum firing rate gallons per hour
deduct for omission
approx. shipping weight
17, 21 25, 29 33. 37
No. 1 No. 2 No. 3
1.75 2.25 3.00
$18.85 20.85 22.85
153 170 180
For discount on repairs, see page 2.
04664
Page 23
This Price List hAS been prepared for the convenience of American-Standard distributors and their trade cus
tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable *>ning
and distribution expense and do not purport to represent actual prices prevail.'
-~*J--
market.
HH-4
BOILER-BURNER UNITS OIL FIRED BOILERS
ST1AM AMO WATI*
AMERicAN'^tandard
HYDRONIC HEATING
A-5 BOILER-BURNER UNITS
Flush jacket
Tested and equipped (or 50 lbs. water working pressure.
boiler-burner
STEAM
WATER
Motors and controls regularly furnished are for 115 volt. 60 cycle current.
------ 1---------
gross l-B=R
output Mbh
IsBsR burner capacity
B*___
net 1=6= R rating
sq ft staam
Mbh
net rating sq ft water
Trade equipment
chimney site
For Built-in Water Heater Arrangement, see page 25.
approx.
shipping weight
A-504-SBCO A-505-SB(T)
A-506-SB(7)
A-504WB(T) A-50S-WB(T) A-506-WB(T)
261 346 426
2.55 3.30 4.00
816 1082 1332
195.8 259.6 319.6
1305 1731 2131
$ 700.00 844.00 952.00
8x 12 x 15 8 x 12 x 20 12 x 12 x 20
A-507-SBCT) A-508-SB(T)
A-509-SB(T)
A-507-WB(T) A-508-WB(T)
A-509-WBCO
508 588 668
4.75 5.55 6.30
1588 1838 2088
381.1 441.1 501.1
2541 2941 3341
1068.00 1153.00 1248.00
12 x 12 x 20 12 x 16 x 25 12 x 16x25
A-510-SBfT) A-511-SBCO
A-510-WBfT) A-511-WB(T)
748 830
7.00 7.65
2338 2594
561.1 622.7
3741 4151
1390.00 1528.00
12 x 16 x 25 16 x 16x30
Nozzlo tiias. gpft. (urnithtd with A-5 units art ss follows: No. A-504, 1 2.50 60'S; A.505, 2 1.65 70`S; A-506 2 2.00 70*S; A-507 1 2.25 A 1 2.50 S0*H; A-508 2 2.75 80"H: A-509. 1 3.00 A 1 3.25 80'H; A-510 2 3.50 B0`S; A-511 1 3.50 A 1 4.00 80*S. Suffix ,JT" denotes unit or boiler with openings in center section* for tankless heaters.
1702 1971 2286
2565 2809 3109
3377 3684
Standard equipment:
bollsr modal
A-504 A-505, A-508 A-507, A-508, A-509 ` A-510
ell bumar
DH-5, sling mounted; 1-stage fuel unit.
45WU-3606 1
82A-7058-1 V 96-7508-1 J
flange mounted; 2-stage (uel unit.
The above burners are furnished with factory installed light sensing flame detector, constant ignition light sensing primary controL
'A-Sll
96-7508
flange mounted; 2-stage fuel unit.
The above burner is furnished with electronic flame safeguard control: RA890E Protectorelay and Q270A base, C7013A photocell, delayed oil valve.
Draft regulator. Drain valve.
Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omission listed on page 25.
For Steam-No. 1 control set: CB-52502 thermostat, PA404A Pressuretrol, nozzle (s). Steam gauge. ASME safety valve. Gauge glass and trimmings.
For Water-No. 3 control set: CB-52502 thermostat, L4080 Aquastat limit control, noz zle (s). Pressure and temperature gauge. ASME relief valve.
A-5 OIL FIRED BOILERS
Flush jacket. Tested and equipped for 50 lbs. water working pressure.
boiler number
STEAM
WATER
gross l--B=R output
Mbh
l=B=R
burner capacity
gph
net l=B =R rating
sq ft steam
Mbh
net rating
sq ft
watar
Trade Price
chimney size
For Built-in Water Heater Arrangement, see page 25.
A-504-SCO A-505S(T) A-506-S(T)
A-507SCT) A-508-S(T) A-509S(T)
A-504-Wm A-505-W(T) A-506-W(T)
A-507-W(T) A-508-W(T) A-509-W(T)
261 346 426
508 588 668
2.55 3.30 4.00
4.75 5.55 6.30
816 1082 1332
1588 1838 2088
195.8 259.6 319.6
381.1 441.1 501.1
1305 1731 2131
2541 2941 3341
$ 560.00 660.00 760.00
860.00 945.00 1030.00
8x12x15 8 x 12 x 20 12 x 12 x 20
12 x 12x20 12 x 16x25 12x16x25
A-510-Sm A-511-S(T)
A-510-Wm A-511W(T)
748 830
7.00 7.65
2338 2594
561.1 622.7
3741 4151
1115.00 1200.00
12 x 16x25 16 x 16x30
Suffix "T" denotes unit or boiler with openings in center sections for tankless heaters.
Standard equipment:
For Steam only: Steam gauge, ASME safety valve, gauge glass and trimmings. Drain valve.
For Water only: Pressure and temperature gauge. ASME relief valve for 50 Ids. Drain valve.
Holes: For optional equipment, see page 25. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Ordering Examples:
1. Boiler-Burner Unit for water with standard equipment: 1 A-507-WB boiler-burner
2. Boiler-Burner Unit for steam with optional equipment: 1 510-SBT boiler-burner with No. 2 control set 3 No. 530 Tankless Heaters 1 3-heater manifold assembly
'3 Boiler only for water with optional equipment 1 A-506-W boiler with jacket extension
F*ag. 24
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market.
approx. shipping
weight
1489 1750 2050 2306 2550 2825 3075 3377
04665
American-Standard
HYDRONIC HEATING
BOILER-BURNER UNITS OIL FIRED BOILERS
IT(AM AND WATU
A-5 OPTIONAL EQUIPMENT
BOILER-BURNER UNITS ONLY:
Arcoflame control sets other than those included in Trade Price of boiler-burner units will be furnished when specified on order at the following added charges:
Control Sot
added charge
Steam control set No. 2................................. $10.00
Water control set No. 4..............................
5.80
Water control set No. 5................................. 14.55
Water control set No. 5-Z............................ 19.35
(Add-on rone Use only with No. 5 control set.)
Detailed description of control sets is shown on page 30.
ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT:
boiler-burner unit
burner model
edded Trade Price chare*
A-507, A-508, A-509 62A-7056-1 F
A-510
96-7506
$90.00 53.00
With RA890E Protectorelay. Q270A base. C7013A photocell, delayed oil valve.
For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than UL. oil burners are available with special electronic flame safeguard controls for A-5 boiler burner units as follows:
boiler-burner unit
A-507, A-508, A-509 A-510 A-511
burner model
62A-7056-1-FFM 96-7507 96-7507
added Trade Price charge
$120.00 87.00 34.00
Two-stage fuel unit is available for DH-5 oil burner at added Trade Price charge of..................................................................$5.00
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Jacket extension; if desired specify on order and add $33.85 to Trade Price of boiler. Jacket extension provides 25" en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbs.
For low water cut-off for use with steam units, see page 30.
Molded refractory combustion chambers for A-5 boilers: Trade Prices are same as "Deduct for Omission" Prices shown below.
If desired, provision for tankless heaters is available at no additional charge. When suffix letter "T" is added on order to unit or boiler numbers, the following number of openings in center sections will be furnished.
Unit No.
Openings
A-504-T
2
A-505-T thru A-508-T
3
A-509-T thru A-511-T
4
Not*: Additional openings can be specified on order.
Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $3.35 each.
NO. 530 TANKLESS HEATER:
No. 530 tankless heater available in single or quantity lot price at $30.65 Trade Price each.
The following table shows the recommended number of heat ers to be used with each boiler and the ratings attained if more than one heater is connected in parallel:
boiler no.
no. of heater*
*rating-gpm
All Sizes All Sizes A-505--A-511 A-508--A-511 A-510--A-511
i 2 3 4 5
4 7 10 13 16
Note: Additional heaters can be added if the heaters are serving different systems and it is not likely that heaters will all be in use at the same time.
'Gallons of water per minute raised from 40 F to 140 F with 200 F boiler water temperature.
Copper pipe manifolds factory assembled for multiple heater parallel hookup shipped in boxes of two manifold assemblies per box when specified with heaters are available at the fol lowing charges:
Manifold assembly
2 heater 3 heater 4 heater
Trade Price per Box
$4.80 6.80 8.80
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit number
A-504 A-505 A-506 A-507, A 508 A-509, A-510. A-511
Heat Llb-O-Rator model No. included
14-A 15-A 15-AA 16-A 17-A
maximum firing rate gallons per hour
2.55 3.30 4.00 5.55 7.65
deduct for omission
$24.85 25.00 33.00 33.00 38.00
approx. shipping weight
158 163 176 180 200
For discount on repairs, see page 2.
04666
Page 25
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market.
HH-4
boiiir-burner units OIL FIRED BOILERS
(TIAM AND WATK
AMERiCAx-iStandard
HYPRONIC HEATING________________
A-7 BOILER-BURNER UNITS
Jacketed and unjacketed. Tested and equipped for 5G lbs. water wuikin pressure. Motors and controls regularly furnished for 115 volt, 60 cycle current.
boilenfcumer unit number
STEAM
WATER
grots IsBssR output
Mbh
IsBbR burner cj peaty
CPh
net 1=0 ==R rating
sq ft steam
Mbh
net rating
sq ft watar
chimney size
unlackatad
Jacketed
Trade Price approx. Trade Price approx. with standarc shipping with standard shipping
equipment weight equipmant weight
A-705-SO-B A-705-WO-B A-706-SO-B A-706-WO-B A-707-SO-B A-707-WO-B
A-708-SO-B A-708-WO-B A-709-SO-B A-709-WO-B A-710-SO-B A-710-WO-B
A-711-SO-B A-711-WO-B A-712-SO-B A-712-WO-B
A-713 SO-B A-713-WO-B A-714-SO-B A-714-WO-B
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
21.45 23.20
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
4331 5061 5981
6944 8020 9075
10125 11118
12112 13105
16 x 16x28 16 x 16x30 16 x 20 x 36
16 x 20 x 42 16 x 20 x 45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
20 x 24 x 70 20 x 24 x 80
$1633.00 1753.00 1928.00
2277.00 2429.00 2607.00
2804.00 2974.00
3297.00 3469.00
4231 4883 5532
6283 6919 7603
8195 8871
9613 10341
$1714.00 1846.00 2033.00
2394.00 2558.00 2748.00
2957.00 3139.00
3474.00 3658.00
4403 5058 5715
6492 7134 7822
8456 9169
9883 10611
'Nozrle sires, tph. 80*S, furnished with A-7 units are as follows: A-705, 2 4.00; A-706. 1 4.50. 1 5.00; A-707, 2 5.50; A-708 1 4.00. 2 4.50; A-709, 1 4.50. 2 5.00; A-710. 1 5.00, 2 5.50: A-711. 3 6.00; A-712. 3 6.50; A-713. 2 5.00, 1 11.00; A-714. 2 5.50. 1 12.00.
Standard equipment:
boiler model
oil burner
A-705, A-706, A-707 A-708, A-709, A-710
A-711, A-712 A-713, A-714
96-7508
]
97-7606
I pedestal mounted;
98-7706
f 2-stage fuel unit
97A Hi-Lo 7668 J
All the above burners include RA890E Protectorelay and Q270A base, C7013A photocell.
On 96-7508 burner, Q270A base is mounted on burner housing. On 97-7606, 98-7606, and 97A Hi-Lo 7668, W415B1 panel is furnished with Q270A base and R488E load relay.
Delayed oil valve with 96, 97 and 98 burners; 3 oil valves with model 97A Hi-Lo.
Draft regulator. Drain valve.
Steel pedestal base in addition to regular 12' base; 8' height for 5 through 7 section; 10" height for 8 through 14 section.
For Steam; PA404A Pressuretrol, nozzles. Steam gauge. ASME safety valve. Gauge glass and trimmings.
For Water L4080 Aquastat limit control, nozzles. Pressure and temperature gauge. ASME relief valve for 50 lbs.
Combustion chamber not furnished. See Installation-Operation and Maintenance Man ual for combustion chambers for A-7 boiler-burner units.
A-7 OIL FIRED BOILERS
Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure.
boiler number
STEAM
WATER
gross IssBasR
output Mbh
IsBsR burner
capacity gph
net 1=B =R rating
sq ft staam
Mbh
net rating
sq ft water
chimney size
unjacketed
Jacketed
approx.
approx.
Trade Price shipping Trade Price shipping
weight
weight
A-705-SO A-706-SO A-707-SO
A-708-SO A-709-SO A-710-SO
A-711-S0 A-712-SO
A-713-SO A-714-SO
A-705-WO A-706-WO A-707-WO
A-708-WO A-709-WO A-710-WO
A-711 -WO A-712-WO
A-713-W0 A-714-W0
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
21.45 23.20
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
Standard equipment:
For Steam only: Steam gauge. ASME safety valve. Gauge glass and trimmings.
For Witer only: Pressure and temperature gauge. ASME relief valve for 50 Ids.
Mtn> For optional equipment, see page 27. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
4331 5061 5981
6944 8020 9075
10125 11118
12112 13105
16 x 16x28 16 x 16 x 30 16 x 20 x 36
16 x 20 x 42 16 x 20 x 45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
20 x 24 x 70 20 x 24 x 80
$1260.00 1380.00 1555.00
1725.00 1877.00 2055.00
2227.00 2397.00
2567.00 2739.00
3882 4518 5149
5720 6330 6990
7556 8208
8912 9616
(1341.00 1473.00 1660.00
1842.00 2006.00 2196.00
2380,00 2562.00
2744.00 2928.00
4054 4693 5332
5929 6545 7209
7817 8506
9182 9886
Ordering Examples:
1. Boiler-Burner Unit with jacket for steam with standard equipment: 1 A-707-S0-B boiler-burner jacketed
2. Boiler-Burner Unit less jacket for wafer with optional equipment: 1 A-710-WO-8 boiler-burner unjacketed with 97-7607 oil burner
3. Boiler only with jacket for steam with optional equipment 1 A-711-S0 boiler with steel pedestal base
04667
HH-4
Pas* 26
Thla Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable and distribution expense and do not purport to represent actual prices prevailing in any particular ma
AMERiCAN-cStandard
HYDRONIC HEATING
BOILER-BURNER UNITS OIL FIRED BOILERS
SHAM AND WATIR
A-7 OPTIONAL EQUIPMENT
ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT:
For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than UL, oil burners are available with special electronic flame safeguard controls for A-7 boiler-burner units as follows:
boiltr*bumr unit
A-705, A-706. A-707 A-708, A-709, A-710 A-711, A-712 A-713, A-714
burner model
96-7509 97-7607 98-7707 97A Hi-Lo 7669
added Trade Price charge
$34.00 15.00 15.00 15.00
Other temperature controls are shown on page 30.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
McDonnell-Miller No. 47-2 and No. 51-2 low water cut-off and feeder combinations: No. 47-2 used with A-705 through A-707 and No 51-2 used with balance of sizes. Special equalizer tap ping for bottom connection of No. 51-2 located 6 inches below water line on front section. Specify No. 47-2 or No. 51-2 on order at current McDonnell-Miller prices.
For No. 369 low water cut-off for use with steam units, see page 30.
OIL FIRED BOILERS only:
Steel pedestal bases for installation under the regularly furnished 12" base for greater base heights will be furnished when specified on order at the follov'ing added charges:
section size 5 through 7 8 through 14
base height 8"
10"
added charge $46.00
7800
04668
Page 27
This Price List has been prepared for the convenience of American-Standard distributor* and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevail!
HH-4
OIL BURNERS
AMERicAN-iStandard
HYDRONIC HEATING
Model 96-7508
OIL BURNERS for A-3, A-5, A-7 and Severn boiler-burner units
moten and controls regularly furnished are for 115 volt, 60 cycle current
--------------- --------------------- 1----
model
1
number
| per hour
tube
|
--------------------
dlam.
length
j mounting
Trade Price
shipping weight
Including constant ignition light sensing primary control with No. 1 steam or No. 3 water control set
DH-5 DH-6 45WU-3606 62A-7056-1
62A-7056-1
.55- 3.00 .55- 3.00 3.00- 4.00 4.00- 6.50 4.00- 6.50
4 4 4`/ 6% 6V6
k
10/.
Including electronic flame safeguard primary control with No. 1 steam or No. 3 water control set
sling
sling
flange flange flange
$115.15 115.15 159.00 175.00 180.00
55 55 58 79 84
96-7506
6.00-12.00 6V4 10K
Including electronic flame safeguard primary control with steam or water limit control
flange
290.00
107
96-7508 97-7606 98-7706 97A Hi-Lo 7668
6.00-12.00 10.00-17.00 14.00-20.00 12.00-24.00
6% 7
8
7`/a
10Vi
pedestal
pedestal pedestal
pedestal
327.00 476.00 501.00 654.00
145 208 214 223
62A-7056-1 burner supplied with 9' draft regulator for A-507 and A-S08, and with 12' draft regulator for A-509 units.
boller-bumer unit oil burner
controls
APR APH A-3 packaged
DH-5 DH-5
DH-5
[Primary controL light sensing cell and
<j controls, except thermo
stat, factory installed. 1 Draft regulator.
A-3 boiler unit. DH-5
A-504 boiler unit DH-5
Severn unit
DH-6
[Primary controL Controls. Light sensing cell factory installed in
burner. (.Draft regulator.
Note: For A-3 units pressure ring is packed with DH-5 burner. For A-504 unit pressure ring, mounting plate and hanger bracket are packed with DH-5 burner.
For Severn unit pressure plate, mounting bracket and draft tube sleeve are packed with draft regulator.
A-505, A-506, A-507, A-508, A-509
45WU-3606 62A-7056-1
A-510
96-7506-1
Note: Model 96-7506-1 furnished
with delayed oil valve.
A-511
96-7506
[Primary controL Con trol set. Light sensing -< cell factory installed in burner. (Draft regulator.
RA890E Protectorelay packed with burner; Q270A base mounted on J burner; C7013A photo cell installed in air tube. Control set. Draft regulator.
A-705, A-706. A-707
96-7508
RAB90E Protectorelay packed with burner; Q270A base mounted on < burner; C7013A photo cell installed in air tube. Limit controL Fire tile. Draft regulator.
A-708, A-709, A-710
97-7606
A-711, A-712 A-713, A-714
98-7706 97A Hi-Lo 7668
No: Delayed oil valve on 96, 97 and 98 burners. One delayed and two mag netic valves on 97A Hi-Lo
burner.
RA890E Protectorelay
packed with burner; C7013A photocell installed in air tube; l W415B1 panel furnished
with Q270A base and R488E load relay. Limit controL Fire tile. Draft regulator.
DH-5 burners for APR and APH furnished with refractory turbulator and are not interchangeable with other DH-5 models.
OPTIONAL ELECTRONIC FLAME SAFEGUARD EQUIPMENT
boller-bumer unit
bumsr model
added Trade Price charge
A-507, A-508, A-509 62A-7056-1-F (instead of 62A-7056-1)
$90.00
A-510
96-7506 (instead of 96-7506-1)
53.00
With RA890E Protectorelay, Q270A base, C7013A photocell, delayed oil valve.
For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than UL, oil burners are available with special electronic controls
at charges to be added to Trade Prices shown above for burn
ers with standard equipment:
boiler-bumer unit
burner model
A-507, A-508, A-509
A-510 A-511 A-705, A-706, A-707 A-708. A-709, A-710 A-711, A-712 A-713, A-714
62A-7056-1-FFM 96-7507
96-7507 96-7509 97-7607 98-7707 97A Hi-Lo 7669
edded Trade Price charge
$120.00 87.00 34.00 34.00 15.00 15.00 15.00
Two-stage fuel unit is available for DH oil burners at added Trade Price charge of..................................................................$5.00
Two-stage fuel unit is standard equipment with 45WTJ, 62A, 96, 97, 97A Hi-Lo and 98 oil burners.
V4O01A delayed oil valve is available installed on 45WU and 62A burners at added Trade Price charge of...................... $13.00
Controls and control sets are jhoum on page 30.
Ordering Eumplet:
04669
1. Oil Burner 1 DH-5 oil burner with No. 5 control set ana z.bU gph 60' S nozzle for A-504-W8T boiler-burner unit.
2. Oil Burner 1 62A 7056-1 oil burner with No. 1 control set, two 2.75 gph 80" H nozzles and 9" draft regulator for A-508-SB boiler-burner unit.
HH-4
Page 28
This Price List has been prepared for the convenience of Amencin-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing In any particular m
American-Standard
HYDRO NIC HEATING
OIL BURNERS
OIL BURNERS for conversion and replacement
motors and controls regularly furnished are for 115 volt. 60 cycle current
1------------------------------------------1-------------------------------I-----------------"
{HP .C; J
model number
cepe city gel.
per hour
elrtube
diem.
length
mounting
with controls
with primary burner with
control end nozzle(s)
nozzle(s) only
only
Including No. 1 steam or No. 3 water control set and constant ignition light sensing primary control if specified
na hln weight
with control
set
DH-8 DH-15 OH-23 '52A 62-1-7000
.65- 3.00 .65- 3.00 .65- 3.00 3.00- 4.00 4.00- 7.00
4 4 4
4`/b eys
8 15 23 iy4 or ioy4 16`/a
f SPECIFY: ] 1 pedestal 1 1 or |
{ flange J pedestal
$115.15 117.15 118.15 155.00 170.00
$103.00 105.00 106.00 141.50 156.50
$ 77.50
79.50 80.50 116.00 131.00
60 64 68 66 73
Optional air tube lengths are available for 52A burner; add to Trade Price for 16" length. $3.50; for 22%* length. $5.50.
Including No. 1 steam or No. 3 water control set if specified and electronic dame safeguard primary control
62 2-7002
| 5.00- 8.00
6'/e
16`/8
| pedestal
275.00 | 261.50
including steam or water limit control if specified and electronic flame safeguard primary control
-
84
96 7501 97-7601 98-7701 97A Hi-Lo 7655
6.00-12.00 10.00-17.00 14.00-20.00 12.00-24.00
6>/8 7 8
7 Vs
16 V, 16>/, 16>/.
16>/
pedestal pedestal pedestal pedestal
290.00 476.00 501.00 654.00
278.50 464.50 489.50 642.50
__ 91 -- 168 -- 176
-- 180
When ordering oil burners be sure to specify nozzle sizes wanted. One nozzle is furnished with DH. two nozzles with 52A, 62. ar.d 96. and three nozzles with 97. 98 and 97A Hi-Lo oil burners.
Nozzles and strainers are as follows:
For DH: Hollow cone. 60*. 0.65*1.25 gph. Solid cone, 60. 1 35-3.00 gph.
For 52A, 62. 96. 97, 98. and 97A Hi-Lo: Solid cone, 70, 1.50-2.00 gph. Solid cone. 80. 2.25-6.50 gph.
Disc-turbulator combinations furnished with model DH oil burners are as follows:
disc-turbulator identification no. capacity range gph
nozzle spray angle
and type
H=hoilow
S=solid
R1 .55-1.10 R2 1.00-1.85 1 .65-1.10 2 .90-1.75
3 1.80-2.30 4 2.35-3.00
60- H 60- H 60- H 60* H (0.90-1.25 gph) 60* S (1.35-1.75 gph)
60" S 60* S
The correct disc-turbulator combination is furnished installed in the DH burner for nozzle size specified on order.
Two*stage fuel unit is available for DH oil burners at added Trade Price charge of.............................................................. $5.00
Two-stage fuel unit is standard equipment with 52A. 62. and 90 series oil burners.
Electric Clock Thermostat: Substitute T852A for CB-52502 thermostat; specify on order control set with suffix "B'\ and add to Trade Price ..................................................................$29.40
Controls and control sets are shoum on page 30.
Deduct from shipping weight of burner with control set:
less control set
3 lbs.
less control set and primary control
9 lbs.
Burners with electronic controls include:
oil burner
controls
62-2-7002 96-7501
97-7601 98-7701 97A Hi-Lo 7655
'control set or limit control if specified. RA890E Protectorelay packed with burner; Q270A base mounted on burner; .C7013A photocell installed in air tube,
limit control If specified. RA890E Protectorelay packed with burn er; C7013A photocell installed in air tube; W415B1 panel furnished with Q270A base .and R488E load relay.
OPTIONAL ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT
oil burner
controls
added Trade Price charge
'52A-4322F
. control set if specified . 1 RA890E Protectorelay packed
I with burner; Q270A base
] mounted on burner; C7013A I photocell installed in air tube :
' add to price of 52A burner
$104.00
For installations requiring Factory Mutual Approval and in
states and municipalities with regulations more stringent
than UL, oil burners are available with special electronic
flame safeguard controls as follows:
oil burner
added Trade Price charge
62-2-7003 96-7502 97-7602 98-7702 97A Hi-Lo 7656
add to price of 62-2-7002 add to price of 96-7501 add to price of 97*7601 add to price of 98-7701 add to price of 97A Hi-Lo 7655
$34.00 34.00 15.00 15.00 15.00
Delayed oil valves are standard on all the above burners with electronic controls. One delayed and two magnetic valves on 97A Hi-Lo burners.
V4001A delayed oil valve is available installed on 52A and 62-1-7000 burners at added Trade Price charge of.......... $13 00
Ordering Examples: 1. Oil Burner 1 DH-23 oil burner with No. 3 control set, 1 50 gph 60 H nozzle, pedestal.
2. Oil Burner 1 96-7502 oil burner with steam limit control, nozzles for 11 gph firing rate.
%
Oil burners listed in this Price Book are approved by the Na tional Board of Fire Underwriters, comply with Commercial Standard CS-75. and are for use with No. 1 or No. 2 fueloil
Capacities of oil burners using No. 1 or No. 2 fueloil are for
installations at sea level and at elevations up to 1,000 feet. Reduce by 4% for each additional 1,000 feet above sea level
For discount on repairs, see page 2.
Page 29
HH-4
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling
and distribution expense and do not purport to represent actual prices prevail '"
-----
/M,i,r market.
04670
CONTROL SETS, CONTROLS LOW-WATER CUT-OFF ZONE VALVE PACKAGES
AMERiCAN-<$tandard
H YDRONIC HEATING
CONTROL SETS FOR BOILER-BURNER UNITS
'f ' Control Mt
no. 1 steam no. 2 steam
for boiler without domestic hot water
boiler with year-round domestic hot water, tankless heater
no. 3 gravity water
no. 4 forced water
boiler without domestic hot water, immenion control boiler without domestic hot water
no. 5
A-3 and A-5 units only with year-round domes
forced water tic hot water
no. 5-Z forced water
no. 6 forced water
A-3 and A-5 units only. Cl no. 5-Z set is re quired for each zone in addition to the first zone which is controlled by the no. 5 control set.)
boiler with year-round domestic hot water, storage tank heater
no. 7
boiler with year-round domestic hot water,
forced water tankless heater
cMtanti of control tot
control number
description
CB-52502 PA404A CB-52502 PA404A L4006A CB-52502 L4080 CB-52502 L4062B
CB-52502 L8024A
CB-52502 R845A
Thermostat Pressuretrol
Thermostat Pressuretrol Aquastat operating control
Thermostat Aquastat limit control
Thermostat Aquastat limit and circulator control
Thermostat Aquastat limit, reverse and operating control, circulator relay
Thermostat Relay
CB-52502 L4006A 14080 R845A
CB-52502 L6006A
L4080 RA89A
Thermostat Aquastat operating control Aquastat limit control Relay
Thermostat Aquastat operating and circulator control Aquastat limit control Relay
add to Trado Price of oil basic control Mt
$10.00
$ 5.80 $14.55 $19.35
$24.30
$22.45
CONTROLS
number
description
Trade Price
number
description
Trade Price
CB-52502
CB-65653 C8-65655 CB-65690 CB-85111 CB-26203 AY-553 AY-686 AY-552 AY-687
TS88A /'T832A
T852A L4006A
AMERICAN-STANDARD
Horizontal thermostat, low voltage, adjustable heater, 0.3 to 1.0 amp J. iS Limit or operating control Reverse acting control Limit or operating control (millivolt) Circulator-limit control Relay High range limit control Low range limit control High range limit control (millivolt) Low range limit control (millivolt)
HONEYWELL
Thermostat (millivolt) Thermostat, low voltage, manual turndown Thermostat, electric clock Aquastat operating control
$ 5.10 8.44 8.44 8.44
14.36 12.60
3.00 3.00 3.00 3.00
4.73
21.96 34.91 10.13
L4080 L4062B , L6006A R8182A
Aquastat limit control
Aquastat limit and circulator control Aquastat operating and circulator control
Aquastat-relay combination, high limit, low limit and circulator control, light sensing constant ignition primary control
R8182C
Aquastat combination, limit and circulator control, light sensing constant ignition primary control
L8024A (i;ivc kt \
L8024G
Aquastat limit, reverse and operating control, circulator relay
Aquastat limit control, switching relay and transformer
PA404A RA89A ,^R845A R8184A
120272
Pressuretrol
Relay, SPST Relay, DPST Light sensing constant ignition primary control Cadmium cell only
$ 8.44 (* 14.29 11.18
45.75
37.76
23.18
25.43 11.51 11.55 14.51 24.94
1.88
No. 369 McDonnell 4 Miller low water cut-off for automatically fired steam A-5, A-7, Severn and Exbrook boilers and/or boiler-burner units....................................Trade Price each $16.75
04671
HYDRONIC ZONE VALVE MANIFOLD PACKAGES
Assembled zone valve manifold packages utilize the thermostat furnished with American-Standard gas and oil packaged units. When the listed packages are to be used with other
forced hot water installations, an additional 2-wire thermo stat is needed to control the first zone,
No. 2-Z package for 2 zones
1 CB-52502 thermostat
2 ZV-20000 3/i' 24 volt zone valves assembled to manifold
1 40 VA
transformer
Trade Price........................... $51.00
No. 3-Z package for 3 zones
2 CB-52502 thermostats
3 ZV-20000 3/t" 24 volt zone valves assembled to manifold
1 40 VA
transformer
Trade Price........................... $76.00
ZV-20000 41' 24 volt zone valve......................................'......................................... Trade Price each $18.00 NOTE: RA89A relay for intermittent circulator operation with zone valves-see Trade Price above.
HH-4
Pags 30
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular m
American-Standard
HYDRONIC HEATING
STOKER FIRED BOILERS
STtAM AND WATIt
SEVERN STOKER FIRED BOILERS
Flush jacket.
boiler number
STEAM
WATER
f---------------------grots
output Mbh
firing rata pounds
per hour
sq ft steam
t insfsMed Mbh
sq ft wattr
Not adapted for Built-in Water Heater (see options below)
Trade Price
ppiwA. hipping
weight
SC-17 (T) SC-21 (T) SC-25 (T)
WC-17 (T) WC-21 (T) WC-25 (T)
146 16 168 18 188 21
SC-29 (T) SC-33 a) SC-37 (T)
WC-29 (T) WC-33 (T) WC-37 (T)
216 247 278
24 27 31
Suffix "T" denotes boiler arranged for but less built-in heater.
456 525 588
675 772 869
109.5 126.0 141.0
162.0 185.3 208.6
730 840 940
1080 1235 1390
$355.00 397.00. 436.00
479.00 542.00 600.00
1053 1220 1301
1457 1534 1687
Standard equipment:
For Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
For Water: Pressure and temperature gauge. ASME relief valve.
Optional equipment:
Boilers arranged for but less Built-in heaters: If desired, for use with heaters No. 590, 594 and 595, add suffix letter "T" to boiler number and add $6.00 to Trade Price of boiler with standard equipment. If 2V4" right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2,00 to Trade Price of boiler.
For low water cut-off for use with steam Severn boilers, see page 30.
Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70.
Below are the ratings and Trade Prices for Built-in heaters available for Severn stoker boilers. For detailed information on ratings, see page 2.
Heater No.
703 594 595 590
Heater Type
tank tank tank tankless
HeaterRatings gals, capacity
66 100 160 3>/2 per minute
Trade Price
$ 9.00 48.00 42.50 36.00
approx. shipping
weight
7 54 51 60
Ordering Examples: 1. Boiler for water with standard equipment: 1 WC-25 boiler 2. Boiler for steam and arranged for but less built-in heater: 1 SC-33-T boiler
Notes: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04672
Page 31
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market.
HH-4
STOKER FIRED BOILERS
ITtAM AMD WATtt
AMERiCAN-^tandard
HYDRONIC HEATING
EXBROOK STOKER FIRED BOILERS
Flush Jacket.
boiler number
STEAM
WATER
grots
output Mbh
l=B=R
burner capacity
Ibs/hr
net l=B =R rating
eq ft steam
Mbh
Not adapted for Built-in Water Heater (see options below)
net rating
sq ft water
Trade Price
chimney elze
approx. shipping
weight
SC-207(T) SC-208CT) SC-209(T)
WC-207(T) WC-208CO WC-209(T)
276
30
863
207.1
1380
$607.00
8x12x25
2150
335
37
1047
251.3
1675
684.00
8x12x25
2313
396
43
1238
297.1
1980
761.00
12x12x30
2628
SC-2010(T)
WC-2010(T)
452
50
1413
339.1
2261
838.00
12x12x30
SC-2011(T)
WC-2011(T)
508
56
1588
381.1
2541
916.00
12x12x35
SC-2012(T)
WC-2012(T)
564
62
1763
423.1
2821
994.00
12x16x40
SC-2013(T)
WC-2013(T)
620
68
1938
465.1
3101
1071.00
12x16x40
Suffix 'T" denotes boiler arranged for but less built-in heater.
Standard equipment:
For Steam: Steam gauge. ASME safety valve, gauge glass and trimmings. For Water. Pressure and temperature gauge, ASME relief valve.
2821 3134 3309 3641
Optional equipment:
Boilers arranged for but less Built-in heater If desired add suffix letter "T" to boiler and add $6.00 to Trade Price of boiler with standard equipment.
Built-in water heaters are available for use with Exbrook "T" type boilers only.
Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $4.25.
For low water cut-off for Exbrook steam boilers, see page 30.
Below are the ratings and Trade Prices for Built-in heaters available for Exbrook "T" type Stoker boilers.
Heater No.
591 592
Heater Type
tank tank
HeaterX*tings gels, capacity
120 200
Trade Price
$32.50 46.50
approx. shipping
weight
35
53
HH-4
Ordering tramples: 1. Boiler for steam with standard equipment: 1 SC-209 boiler
2. Boiler for water and arranged for built-in heater-. 1 WC-2011-T boiler 1 Heater opening cover plate
Notes: For complete information on boiler ratings, see page 2. For discount on repairs, see 0age 2.
Page 32 This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable ' and distribution expense and do not purport to represent actual prices prevailing in any particular i
04673
boiler number
STEAM
WATER
3-SC-8 3-SC-9
3WC-8 3-WC-9
AMEMCAN-<$tandard
HYDRONIC HEATING
STOKER FIRED BOILERS
STEAM AND WATER
gross output
Mbh
706 798
NO. 3 REDFLASH STOKER FIRED BOILERS
Jacketed and unjacketed.
firing rate pounds per hour
78 88
net installed rating
sq ft staam
Mbh
sq ft water
2207 2494
529.6 598.6
3531 3991
unjacketed
Trade Price
approx. shipping
weight
$1135.00 1260.00
3652 4041
facketed
Trade Price
approx. shipping
weight
$1227.00 1356.00
3827 4224
Standard equipment:
For Steam: Steam gauge. ASME safety valve, gauge glass and trimmings. For Water: Pressure and temperature gauge, ASME relief valve.
Optional equipment:
External water heater tappings available at following added charges: ping and $2.00 per jacket punching.
Ordering Eumples: Boiler for steam with jacket with standard equipment: 1 3-SC-9 jacketed boiler
$2 00 per section tap
A-7 STOKER FIRED BOILERS
Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure.
boiler number
STEAM
WATER
gross l=B=R
output Mbh
l=B=R burner
capacity Ibs/hr
net 1=8 =R rating
sq ft steam
Mbh
net
sq ft water
A-705 SC A-706SC A-707-SC
A-705-WC A-706-WC A-707WC
A-708-SC A-709-SC A-710-SC
A-708-WC A-709-WC A-710WC
A-711-SC A-711WC A-712-SC A-712-WC
A 713-SC A-713-WC A-714-SC A-714-WC
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
95 111 131
151 172 194
215 236
257 278
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
4331 5061 5981
6944 8020 9075
10125 11118
12112 13105
chimney
unjacketed
Trade Price
shipping weight
jacketed
Trade Price
approx. shipping
weight
16 x 16x28 16 x 16 x 30 16 x 20 x 36
$1260.00 1380.00 1555.00
16x20x42 16 x 20 x 45 20 x 20 x 50
1725.00 1877.00 2055.00
20 x 20 x 55 20 x 20 x 60
2227.00 2397.00
20 x 24 x 70 20 x 24 x 80
2567.00 2739.00
3882 4518 5149
5720 6330 6990
7556 8208
8912 9616
$1341.00 1473.00 1660.00
1842.00 2006.00 2196.00
2380.00 2562.00
2744.00 2928.00
4054 4693 5332
5929 6545 7209
7817 8506
9182 9886
Standard equipment: For Steam: Steam gauge, ASME safety valve, gauge glass and
trimmings.
For Water: Pressure and temperature gauge, ASME relief valve for 50 lbs.
Optional equipment:
Steel pedestal bases for installation under the regularly fur nished 12" base for greater base heights, will be furnished when specified on order at the following added charges:
section size 5 thru 7 8 thru 14
base heights 8" 10"
trade price $46.00 76.00
For low water cut-off for A-7 steam boilers, see page 30.
Ordering Examples:
Boiler for water with jacket with optional equipment. 1 A-708-WC jacketed boiler 1 8" steel pedestal base
Notes:
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04674
Page 33
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market.
HH-4
HAND FIRED BOILERS
SUAM AND WATI8
AMERicAN-<$tandard
HYDRONIC HEATING
SEVERN HAND FIRED BOILERS
STEAM
boiler number
WATER
S-17 S-21 S-25
S-29 S-33 S-37
W-17 W-21 W-25
W-29 W-33 W-37
gross output
Mbh
194 244 296
328 364 396
*qft teem
net Installed rating Mbh
*q ft water
353 453 553
630 710 783
84.7 108.7 132.7
151.3 170.5 187.9
565 725 885
1009 1137 1253
Price
$393.00 456.00 522.00
574.00 632.00 681.00
approx. hipping
weight
1243 1413 1521
1686 1783 1956
HH-4
Standard Equipment:
For Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
For Water Pressure and temperature gauge, ASME relief valve, automatic damper regulator and firing tools.
Built-in Heaters:
If 2%" right or left side tapping in back section for Built-in screw-in heaters No. 701, 702 or 703 is desired specify on order and add $2.00 per tapping to Trade Price of boiler.
Below are the ratings and Trade Prices of Built-in heaters available for Severn hand fired steam boilers.
Hester No.
Heater Type
Heater ratings gals, capacity
Trade Price
approx. shipping
weight
701 702 703
tank tank tank
60 40 100
$8.50 8.00 9.00
5 4 7
Note: Built-in water heaters are not recommended for hand fired water boilers.
Ordering Example: Boiler (or steam with built-in heater: 1 S-25 boiler with 2V4" tapping on right hand side of back section 1 702 heater
Notes: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04675
Pg. 34
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable filing and distribution expense and do not purport to represent actual prices prevailing in any particular }
STEAM
boiler number
WATER
2-S-7 2-S-8 2-S-9
2-S-10 2-S-ll 2S-12
2-W-7 2-W-8 2-W-9
2-W-10 2-W-ll 2-W-12
American-Standard
HYDRONIC HEATING
HAND FIRED BOILERS
(TCAM AND WATIA
NO. 2 REDFLASH HAND FIRED BOILERS
Jacketed and unjacketed.
greet output
MMt
net Installed rating
sq ft steam
Mbh
qft water
unjec keted
Trade Price
approx. shipping
weight
Jacketed
Trade Price
approx. shipping
weight
464 536 606
676 744 812
940 1111 1281
1453 1623 1794
225.7 266.7 307.5
348.8 389.5 430.5
1505 1778 2050
2325 2597 2870
$ 707.00 785.00 863.00
942.00 1021.00 1099.00
2293 2466 2782
2999 3313 3503
$ 775.00 857.00 939.00
1022.00 1105.00 1187.00
2390 2572 2897
3122 3446 3644
Standard Equipment:
For Steam: Steam gauge. ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
For Water Pressure and temperature gauge. ASME relief valve, automatic damper regulator and firing tools.
Ordering Example: Boiler for steam less jacket with standard equipment: 1 2S-9 boiler unjacketed
STEAM
boiler number
WATER
3-S-6 3-S-7 3-S-8 3-S-9
3-W-6 3-W-7 3-W-8 3-W-9
NO. 3 REDFLASH HAND FIRED BOILERS
Jacketed and unjacketed.
grots output
Mbh
net installed rating
sq ft steam
Mbh
sq ft wstsr
unjacksted
Trade Price
approx. shipping
weight
jacketed
Trade Price
approx. shipping
weight
696 814 932 1046
1503 1799 2100 2400
360.6 431.8 504.1 576.0
2404 2879 3360 3840
$ 963.00 1107.00 1251.00 1395.00
3243 3698 4110 4549
$1047.00 1195.00 1343.00 1491.00
3397 3870 4285 4732
Standard Equipment:
For Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
For Water: Pressure and temperature gauge. ASME relief valve, automatic damper regulator and firing tools.
Note: Buckwheat coal grate bars will be furnished at no additional charge when specified on order.
Ordering Example: Boiler for water with jacket with standard equip ment: 1 3-W-7 boiler jacketed
Notes: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04676
Page 35
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any
HH-4
HAND FIRED BOILERS
ST1AM AMO WAT1K
AMERicAN-<Standafd
H YD RON I C HEATING
'' . .c.
A-7 HAND FIRED SOILERS
Jacketed and unjacketed. Tested and equipped tor SO lbs. water working pressure.
boiler number
STEAM
WATER
grass
IssBsR output
Mbh
net IssBsR
iqft steem
Mbh
net rating
4 ft water
chimney six*
un|acketed
Trade Price
apprax.
shipping waight
(ecfcated
Trade Price
approx. shipping
weight
A-705-S A-705-W
1122
2606
625.4
4169 16 x 16 x 40 $1393.00 4294 $1474.00 4466
A-706-S A-706-W
1298
3101
744.3
4962 16 x 20 x 45
1519.00 5006
1612.00 5181
A-707-S A-707-W
1510
3725
894.0
5960 20 x 20 x 50
1696.00 5738
1801.00 5921
A-708-S A-708-W
1708
4342
1042.1
6947 20 x 20 x 55
1877.00 6392
1994.00 6601
A-709-S A-709-W
1910
5008
1202.0
8013 20 x 20 x 60
2006.00 7199
2135.00 7334
A-710-S A-710-W
2108
5681
1363.5
9090 20 x 24 x 65
2164.00 7858
2305.00 8077
A-711S A-711-W
2288
6326
1518.2
10122 20 x 24 x 70
2336.00 8506
2489.00 8767
A-712S A-712-W
2456
6947
1667.3
11115 24 x 24 x 75
2496.00 9231
2661.00 9529
HH-4
Standard equipment:
For Steam: Steam gauge. ASME safety valve. Gauge glass and trimmings, automatic damper regulator and firing tools.
For Water ASME relief valve for 50 lbs. Automatic damper regulator and firing tools. Pressure and temperature gauge.
Ortferiog Example: Boiler for water with jacket with standard equipment: 1 A-706-W boiler jacketed
Notes: For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
04677
Pt| 36
Thi* Price List has been prepared for the convenience of American-Standard distributor* and their trade <r
tomers only. The trade price* Rhown represent fixed markups over distributor prices to reflect reasonable
............................
- ----- 1'--j av ns-tintlj* marl
AMERiCAN-<$tandard
HYDRO NIC HEATING
RADIATORS RADIATOR ACCESSORIES
width
helfM. Inches
tq ft per section
Trade Price per sq ft
6 tube 3 tube 4, 5, 6 tube 4, 5 tube 4, 6 tube
32 3.7 $1.25
25 1.6 1.25
25
2.0,2.4,3.0
1.18
22
1.8.2.1
1.23
19
1.6,2.3
1.25
Arco Radiators are regularly furnished with two and one-half inch (214") legs but can be supplied on Special Order with four and one-half inch (414") legs, or without legs, at no extra charge.
Arco Radiators sold only In even number of sections up to a maximum of 56 sections, for purpose of estimating shipping weights, use 4V4 pounds per sq. ft.
Ordering Example: 1-12 Section 25" Arco 4 Tube legless 14 x Vi
SUNRAD RADIATORS
type
sq ft per section
Trad# Price per sq ft
M 5x20 M 7i/2 x 23
2.25 3.40
$1.49 1.56
Sunrad Radiators are regularly furnished with two and threequarter inch (2%") legs but can be supplied on special order without legs, at no extra charge.
Sunrad Radiators sold in even number of sections from 4 to
30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections.
Important: Increase size 5% for recessed installation--14" air space top and sides. W at back. Increase size 15% for tightly recessed installation--no clearance top or sides, V4" air space at back.
Sunrad Grilles
Inlet--Stamped Lattice Type............................per section $0.19
Special No. 16 Gauge with Locking Device................................... Price on application
For purposes of estimating shipping weights, use 6 pounds per sq ft for MS X 20.
Ordering Example:
use 6V4 pounds per sq ft for M714 x 23.
1-10 Section M5 x 20 Sunrad T-4 V4 x 14
for1-Type M Sunrad Grille above.
04678
RADIATOR
Arco Brackets: For 3, 4, 5, 6 tube, with Wall Plate.................................
Trade Price h
$0.83
ACCESSORIES
Nipples, Plugs, Bushings, etc.: y*", 1", 1>4", l>/2" Plugs, Bushings............................
Trade Price ,,ch
$0.23
Arco Radiator Pedestals: Vi" and 1"........................................................................... l'/i" .......................................................................................
0.32 0.41
s/4", 1", l1/*" Slip Nipples............................................... Vs" Air Vent Plugs.............................................................. Radiator Rod Nuts..............................................................
0.23 0.01 0.01
Sunrad Brackets: For M5 x 20 and M7i/2 x 23........................................... 0.65
Radiator Rods................................................. per section 0.01 Above item* available for use only with our Radiator products.
Page 37
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling
and distribution expense and do not purport to represent actual prices prevailing in -
market.
HH-4
BASEBOARD PANELS
American-^Standard
HYDRONIC HEATING
P.ADIANTPJM BASEBOARD PANELS
MEMBER
New Model 8 Steam Rating per lineal foot 2.75 sq ft
SEE CURRENT LITERATURE FOR APPROVED l=B=R STEAM AND HOT WATER RATINGS
per lineal foot Trade Price-- $3.06
$1.12
New Model 8 Radiantrim Panel lengths (2Vi ft to 30 ft) are made up from the following sections:
1 Vi ft Left hand end section
1 ft Right hand end section
2 ft Left hand end section
2 ft Right hand end section
2 ft Center section
Assembly length with legs and tappings at each end:
2 ft Double end section
New Model 8 Accessories
Price
Extension Panel and Brackets (Two 6 ft lengths perbox) ........................................ $8.40
Extension Panel Retaining Bracket............................ 0.22 Extension Panel Cover Strip........................................ 0.53 Assembly Clamp .............................................................. 7.70 Short -- Compression Corner Connection.................. 2.00 Long - CompressionCornerConnection..................... 2.25
Retaining Block ................................................................ 0.15 Adjustable Leg .................................................................. 0.20 Tie Bolt ................................................................................ 0.06
-frThese items are regularly furnished as required with New Model 8 Ra diantrim Panels and Accessories. Prices are shown for repair or re placement purposes.
Packed in quantity of 10 per box (Available only in this minimum quantity) per box of to
Inverted Corner Cover...................................................... $10.50 Extended Inverted Corner Cover.................................... 17.50 Projecting Corner Cover.................................................. 14.20 Valve Enclosure (all R.H. or L.H.) ................................ 12.35 End Box (all R.H. or L.H.) .............................................. 7.00
For purpose of estimating shipping weights, use 414 pounds per sq. ft.. 12.16 pounds per lineal foot.
Ordering Example: 1-7 ft. New Model 8 Radiantrim Panel. l-8ox of New Model 8 Inverted Corner Covers.
per lineal foot Trade Price- $3.61
$1.12
Model 10 Radiantrim Panel lengths (2)4 ft to 30 ft) are made up from the following sections:
1 hi ft Left hand end section
1 ft Right hand end section
2 ft Left hand end section
2 ft Right hand end section
2 ft Center section
Assembly length with legs and tapping: at each end:
1 Vfe ft Double end section
2 ft L ouble end section
Model 10 Accessories
price
Extension Panel and Brackets
(Two 6 ft lengths per box) ........................................$13 10
Extension Panel Retaining Bracket............................ 0.22
Extension Panel Cover Strip........................................ 0.53
Assembly Clamp................................................................ 7.70
Short-- Compression Corner Connection............
2 00
Long -- Compression Corner Connection.................. 2 25
Retaining Block ................................................................ 0.15
Adjustable Leg .................................................................. 0.20
Tie Bolt ................................................................................ 0.06
These items are regularly furnished as required with Model 10 Ra diantrim Panels and Accessories. Prices are shown for repair or re placement purposes.
Packed in quantity of 10 per box
Vrice
(Available only in this minimum quantity) perboxoflO
Inverted Corner Cover .......................................................$13.10 Extended Inverted Corner Cover.................................. 23.60 Projecting Corner Cover .................................................. 16.60 Valve Enclosure (all R.H. or L.H.) ................................ 18-35 End Box (all R.H. or L.H.) .............................................. 9.80
For purpose of estimating shipping weights, use 4J/ pounds per sq. ft., 16.15 pounds per (meal foot.
Ordering Example:
1-7 ft. Model 10 Radiantrim Panel. 1-Box of Model 10 Right Hand Valve Enclosures.
Bag No.
0 1 2
EXTRA RADIANTRIM ACCESSORY BAGS
For
Double Leg Section 2hi'-S' Panel Length 6 Vi'-12' Panel Length
Trade Price
$ .65 .80
1.80
Bag No.
3 4 5
For
12VV'-18' Panel Length 18)4'-24' Panel Length 24)4'-30' Panel Length
Sufficient quantities of these bags are regularly furnished with Radiantrim Panels. Prices shown are for extra bags as may be required.
Trade Price $2.65 3.50 4.50
04679
HH-4
Page 38
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable s and distribution expense and do not purport to represent actual prices prevailing in any particular m
AMERicAN-fStandard
HYDRONIC HEATING
HEATRIM BASEBOARD PANELS
HEATRIM PANELS
MEMBER
Model N50-L (i/2" tube) Model N85-L (%' tube) Model N110-L (l'tube)
Model N50-HH (>/2' tube) Model N85-HH (%' tube) Model N110-HH (l'tube)
SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS
COMPLETE UNITS:
shipappinpgrowx.alght
Model N85-L-Packaged in 3', 4', 5', 6', 7' and 8' lengths--completely assembled (package contains element, one-piece back and top section, front panel damper, snap-in support brackets, element slide cradles and 1 set damper joining pieces). Finished with white prime coat of paint.
Ordering Example: 1-N85-L, 3 ft. length, Heatrira unit.
per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 7 ft. length per 8 ft. length
per lineal foot
9 11 14 18 20 22
2 Vi
Trade Prlca
$ 5.85 7.80 9.75
11.70 13.65 15.60
1.95
Model N85HH-Packaged in 3', 4', 5', 6', 7' and 8' lengths-completely assembled (package contains element, one-piece back and top section, front panel, damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
Ordering Example: 1--N85-HH, 7 ft. length, Heatrim unit.
HEATING ELEMENTS ONLY:
per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 7 ft. length per 8 ft. length
*per lineal foot
10 13 16 20 23 26
3 Vi
7.35 9.80 12.25 14.70 17.15 19.60
2.45
Model N50 (t4" tube) -Individually boxed, packaged six equal lengths per bundle.
Ordering Example: 1-Bundle N50, 3 ft. lengths, Heatrim elements.
per bundle of six 3' lengths per bundle of six 4' lengths per bundle of six 5' lengths per bundle of six 6' lengths per bundle of six 7' lengths per bundle of six 8' lengths
*per lineal foot
10 13 17 22 25 28
Vi
16.20 21.60 27.00 32.40 37.80 43.20
.90
Model N85 (* tube) - Individually boxed, packaged six equal lengths per bundle.
Ordering Example: 1--Bundle of N85, 5 ft. lengths, Heatrim elements.
per bundle of six 3'lengths per bundle of six 4' lengths per bundle of six 5' lengths per bundle of six 6' lengths per bundle of six 7' lengths per bundle of six 8' lengths
*per lineal foot
12 16 19 24 27 30
Vi
18.00 24.00 30.00 36.00 42.00 48.00
1.00
Model N110 d" tube) - Individually boxed, packaged six equal lengths per bundle.
Ordering Example: 1-Bundle of NUO, 8 ft. lengths, Heatrim elements.
per bundle of six 3' lengths per bundle of six 4' lengths per bundle of six 5' lengths per bundle of six 6' lengths per bundle of six T lengths per bundle of six 8' lengths
per lineal foot
13 Vi 18 22`/2 27 31 Vi 36
%
21.60 28.80 36.00 43.20 50.40 57.60
1.20
For comparativa and estimating purposes only.
Page 39
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only. The trade prices shown represent fixed markups over distributor prices to r
and distribution expense and do not purport to represent actual prices prevailing in
04680
HH-4
HEATRIM PANELS AND ACCESSORIES
AMERicAN-tStandard
HYDRONIC HEATING HEATRIM BASEBOARD PANELS
ill w
ENCLOSURES ONLY:
Model L-Multiple packaged in 3', 4', 5', 6', 7', 8', 10' and 12' ieiigui* Uiidsatiiiuicu-UUVL- cv|ual lengths pel' uOX tpoCisagt
contains 3 one-piece back and top sections, 3 front panels. 3 dampers, loose snap-in support brackets, element slide cradles and 2 sets joining pieces). Finished with white prime coat of paint.
Ordering Eumple:
1-Box 5 ft. lengths Model L Enclosure only.
Model L-Individually packaged in 3'. 4', 5', 6', T and 8' lengths
unassembled. (Package contains one-piece back and top section. front panel, damper, loose snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
Ordering Example:
1-7 ft. length Model L Enclosure only.
Model HH-Multiple packaged in 3', 4'. 5'. 6', 7' and 8` lengths
unassembied-three equal lengths per box (package contains 3 one-piece back and top sections. 3 front panels, 3 dampers. loose snap-in support brackets, element slide cradles and 2 sets joining pieces). Finished with white prime coat of paint.
ft.1-Box 4 lengths Model HH Enclosure only.
Model HH-Individually packaged in 3', 4\ 5'. 6', 7' and 8'
lengths unassembled. (Package contains one-piece back and top section, front panel, damper, snap-in support brackets. element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
Ordering Example:
1--3 ft. length Model HH Enclosure only.
per box of three 3' lengths per box ot tnree 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 7' lengths per box of three 8' lengths per box of three 10' lengths per box of three 12' lengths
'per lineal foot
| per 3 ft. length per 4 ft. length
J per 5 ft. length per 6 ft. length
i per 7 ft. length per 8 ft. length V
'per lineal foot
/ 1 per box of three 3' lengths ' per box of three 4' lengths 7 per box of three 5' lengths
per box of three 6' lengths per box of three 7' lengths per box of three 8' lengths (
'per lineal foot
r
1 per 3 ft. length
j per 4 ft. length
/ per 5 ft. length
' per 6 ft. length
1
per 7 ft. length per 8 ft. length
\
'per lineal foot
HEATRIM BASEBOARD PANEL ACCESSORIES
21 2/ 34 41 48 54 68 82
2
8 10 12 14 17 19
2
24 30 38 46 521/a 59
21/2
8 11 14 16 171/z 21
2i/2
MODEL L ENCLOSURE ACCESSORIES:
Inverted Corner Cover-one-piece front and top section...........................packed per box of 10 Inverted Corner Cover-hinged front and top section................................packed per box of 10 Inverted Corner Cover-back section only............................................... packed per box of 10 Projecting Corner Cover..................................................................................... packed per box of 10
Valve Enclosure-6" wide...........................packed all right hand or all left hand per box of 10 End Cover-4" wide....................................... packed all right hand or all left hand per box of 10 End Cap-1 V4" wide....................................... packed all right hand or all left hand per box of 10
Wall End Piece-3V<" wide....................................................................................packed per box of 10
Filler Pieces-7" wide............................................................................................packed per box of 10
Filler Pieces-14" wide..........................................................................................packed per box of 5
Joining Pieces-2" wide............................................................................. packed per box of 20 sets
Return Tubing Wire Hangers-for Vi" and y<" tubing only
packed per bag of 50
Connecting Tubing Wire Hangers-for ln" and %" tubing only
packed per bag of 50
Extra Snap-in support bracket with slide cradle........................ packed per box of 20 sets
Note: Finished with white prime coat of paint.
MODEL HH ENCLOSURE ACCESSORIES:
Inverted Corner Cover-one-piece front and top section.................... packed per box of 10 Inverted Corner Cover-hinged front and top section............................... packed per box of 10
Inverted Corner Cover-back section only................................................... packed per box of 10 Projecting Corner Cover................................................................................... packed per box of 10
Valve Enclosure-6" wide...................... packed all right hand or all left hand per box of 10 End Cover-4" wide...................................... packed all right hand or all left hand per box of 10 End Cap-1 Vi" wide...................................... packed all right hand or all left hand per box of 10 Wall End Piece--3Vi" wide.................................................................................packed per box of 10
Filler Pieces-14" wide..................................................................................... packed per box of 5
Joining Pieces-2" wide........................................................................... packed per box of 20 sets
Return Tubing Wire Hangers-for Vi", " and 1" tubing ..
packed per bag of 50
Connecting Tubing Wire Hangers-for Vi". V and 1"tubing.
packed per bag of 50
Extra Snap-in support, bracket with slide cradle..............................packed per box of 20 sets
Not*: Finished with white prime coat of paint
For comparative and estimating purposes only. NOTE: Add 25% to accessory unit price when ordered in less than quantities indicated above.
HH*4
Page 40
This Price List has been prepared for the convenience of Amei icon-standard distributors and their trade cus tomers oniy. The trade prices shown represent fixed markups over distributor prices to reflect reasonable sell jnd distribution expense and do not purport to represent acu;..i prices prevailing m any particular mar
Trd
Pric*
$ 7.20 9.60
12.00 14.40 16.80 19.20 24.00 28.80
.80
2.70 3.60 4.50 5.40 6.30 7 ?n
.90
12.06 16.08 20.10 24.12 28.14 32.16
1.34
4.35 5.80 7.25 8.70 10.15 11.60
1.45
$ 8.00 10.50 4.50 10.00 17.50 12.50 5.00 3.00 6.50 6.00 5.00 2.00 2.00 7.00
8.00 10.50 4.50 11.50 18.00 12.50
8.00 4.00 7.75 7.00 2.00 2.00 7.00
04681
American'Standard
hyoronic heating
convectors
ARCO CONVECTORS
SPECIAL SERVICE LINE when sold in combination with standard cabinets
COMBINATION PRICE:
The actual output in square feet of catalog rating--Steam (215#F) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination.
The total price of each order equals the amount of catalog
square feet ordered multiplied by the price per square foot. plus the unit extra charge multipled by the total number of units ordered.
SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS
cabinet type
description
Trade Price
per sq ft
unit extra charge
cabinet type
description
Trade Price
per sq ft
unit extra charge
F FG
W FS FSG
S FR
FRG
FRGB
Floor Type-free standing
Floor Type-free standinginlet grille................................
Wall Hung-flat top..................
Free Standing-sloping top ...
Free Standing-sloping top-- inlet grille................................
Wall Hung-sloping top..........
Fully recessed-^" beveled edges .........................................
Fully recessed-^" beveled edges-inlet grille
Fully recessed-^" beveled edges--inlet grille with bottom overlap......................
$1.35 1.39 1.35 1.42 1.45 1.35 1.34 1.38
1.38
$17.10 17.10 17.10 17.95 17.95 17.10 18.15 18.15
21.30
PR Partially recessed-V\ l V\ 1'k". 3". 5". 7" flanged edges $1.34
PRG
Partially recessed~'k". 1 >6". 2 V 3*'. 5". 7" flanged edgesinlet grille
1.38
PRGB
Partially recessed--V. IV 2 V 3". 5". 7" flanged edges-- inlet grille-with bottom overlap
1.38
PFG
Plaster Front-fullv recessed-- outlet and 3 side inlet grille. 3V' plaster offset....................
1.48
PFGB Plaster Front-fully recessed-- outlet and 4 side inlet grille. 3/" plaster offset . .
1.48
$19.75 19.75
22.90 23.30 25.30
Note: Where more than 20^ of the convectors on a given order are in the No. 4 depth, add $.08 per sq. ft. lEDRi to the Trade Price of the No. 4 depth unit only.
Standard Cabinets are furnished in:
Prime painted sheet steel-reinforced. No. 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors listed in cur rent literature
For illustrations oj cabinets, see page 42.
For cabinet extras, see page 45
Ordering Example: 1 --F-458-20 Arco Convector Unit X-4
* i/2
For estimating shipping weights of Arco Convector Units use 114 pounds per square foot for cabinet portion. 3 V4 pounds per square foot for element portion.
ARCO CONVECTOR -- steam or water
ELEMENTS ONLY (when sold less cabinets)
convector length inches
No. 4 33/i" depth
unit no.
approx. shipping
weight
Trade Price
No. 6 5s/b" depth
unit no.
approx. shipping
weight
Trade Price
No. 8 7 5/a " depth
unit no.
approx. shipping
weight
Trade Price
No. 10 9`/2" depth
unit no.
approx. shipping
weight
Trade Price
18
418
39 $12.41
618
57 $18.28 818
71 $23.02 1018
84
23
423
50 16.02 623
73 23.57 823
92
29.79 1023
110
28
428
61
19.62
628
90
28.90 828 113
36.57 1028
136
33
433
72
23.25
633
106
34.30 833 134
43.33 1033
162
38
438
83
26.86
638
123
39.62 838 155
49.99 1038
188
43
443
94
30.36
643 139
44.92 843 176
56.75 1043
213
48
448 105
33.95
648
146
50.22 848 197
63.53 1048 238
53
453 107
37.57
653 172
55.51 853 218
70.30 1053
264
58
458 128
41.19
658
189
60 82 858 239
77.07 1058 289
63
463 139
44.79
663 206
66.22 863 260
83.82 1063
314
Ordering Example: 1--418 Arco Cast Iron Element only-No Cabinet X-4 Vz x Vz
Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets For sizes not listed above-price on application.
$27.76 35.88 44.11 52.23 60 47 68 60 76 83 85.06 93.20
101.30
Page 41
HH4
Tins Price Lis\ has been prepared tor the convenience of American-Standard distributors and their trade cus-
lomcrs only The trade prices shown represent fixed markups over distributor prices to rebec
and distribution expense and do not puiport to represent actual prices prevailing in any
04682
CONVECTORS
fAMERiAN'<$taitdard
HYDRONIC HEATING
Type K (Stock Modal) Typo F (Special Service)
TypaS
TypeW
MULTIFIN CONVECTORS
CoiriuiutiiidA Pfkol The actual output In iquare feet of catalog rating--Steam <215*F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination.
The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered.
SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS
cabinet type
description
Trade Price
per iqfl
unit extra charge
Stock Model K | Floor Type--free standing.............................................................. | $0.40* |
$11.10
'Note: Price shown for estimating purposes only. For expanded prices, see page 44. For cabinet extras, see page 45.
Special Service
F FG W FS FSG S FR FRG FRGB
PR PRG
PRGB
PFG
PFGB
Floor Type-free standing.............................................................. Floor Type-free standing-inlet grille...................................... Wall Hung-flat top..........................................................................
$ .45 .48 .44
Free Standing-sloping top............................................................ Free Standing-sloping top-inlet grille.................................... Wall Hung-sloping top..................................................................
.43 .46 .40
Fully recessed-^" beveled edges.............................................. Fully recessed-^" beveled edges-inlet grille...................... Fully recessed-^" beveled edges-inlet grille with
bottom overlap ............................................................................
.47 .50
.50
Partially recessed--V4", 1%", 2Vi", 3", 5", 7" flanged edges Partially recessed-V4 ", 1V4", 2t4, 3", 5", 7" flanged edges
-inlet grille.................................................................................... Partially recessed-V4". It4", 2t4", 3", 5", 7" flanged edges
-inlet grille-with bottom overlap..........................................
.51 .54 .54
Plaster Front-fully recessed--outlet and 3 side inlet grille, plaster offset..........................................................................
Plaster Front-fully recessed-outlet and 4 side inlet grille, %" plaster offset..........................................................................
.50 .50
$13.00 13.00 13.00 13.75 13.75 13.00 13.75 13.75
16.75 16.00
16.00
20.00
14.50
16.50
HH-4
Note: Where more than 20% of the special service convectors on a given order are in the No. 4 depth, add $.08 per sq ft (EDR) to the Trade Price of the No. 4 depth units only.
Type PR
Note: For cabinet extras, see page 45.
For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifln convectors:
Multifin stock model -- 1.13 pounds. Also see page 44.
Multifln cabinets (less element) -- 1V4 pounds.
Multifln cabinets (with element):
Types F, FR, PR --Impounds.
Types FS, W
-- 1 % pounds.
Type S
-1 Vi pounds.
Ordering Eismplis:
Stock Model Multifin with tn optional feature: 1 K-840-24 Multifin with Metal Trim Strips.
Special Service Multifin with an optional feature: 1 PR-640-32-2V4 Flange, Multifin with Knob Damper.
04683
P,,. 42
This Price List has been prepared for the convenience of American-Standard distributors and their t-- tomeri only. The trade price* shown represent fixed markups over distributor prices to reflect reasons: and distribution expense and do not purport to represent actual prices prevailing in any particula
AMERiCAN-<Standard
hydronic heating
MULTIFIN CONVECTORS - continued
BATHROOM MULTIFIN CONVECTORS
unit no.
Type "fTP* (top outlet) sq. ft output
Typo "BP*
(front outlet) tq. ft. output
Trede Price
416-13 420-13 424-13
5.3 4.6 $14.80
6.9 6.0
15.60
8.5 7.4
16.40
416-15 420-15 424-15
6.3 8.2 10.1
5.4 7.1 8.8
15.20 16.20 17.20
Net*: Heights indicated are nominal. Actual height is S'* less. Knob damper available on IS' high front outlet grille ("BF") units only. For damper price see cabinet extras, page 45.
Ordering Eiaraplt: BF-416-1S Multifin Convector with Knob Damper.
convectors
convector length inches
20 24
28 32 36
40 44 48
56 64
Elements only (when sold less cabinets) -- steam or wafer
No. 4 depth
No. 6 depth
No. 8 depth
No. 10 depth
unit no.
approx. shipping
weight
Trade Price
unit no.
approx. shipping
weight
Trade Price
unit no.
approx. shipping
weight
Trade Price
unit no.
approx. shipping
weight
Trade Price
420
8 $ 8.60 620 13 $10.60
424 10
9.30
624
16
11.60
428 432 436
12 14 16
10.00 10.80 11.80
628 632 636
19 22 25
12.75
13.60
832 27 $17.00
14.75
836
31
18.40 1036 41 $22.75
440 444 448
18 20 22
12.60 13.55 14.25
640 644 648
28 31 34
15.85 17.00 18.20
840 848
35 43
19.85 1040
46
22.65 1048
56
24.50 27.85
456 464
26 30
15.85 17.60
656 664
40 46
20.20 22.60
856 864
51 59
25.30 28.10
1056 1064
66 76
31.05 34.80
Note: Elements only are furnished less floor supports. Multifin elements for special one-pipe steam header application--not available.
Orderint Example: 1--420 Multifin Element only-no cabinet.
Ratings:
Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee.
Standard Cabinets:
Standard cabinets are furnished in prime painted sheet steel-reinforced. No. 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline front discharge grille, and open bottom inlet arch. In heights, lengths and depths to accommodate convectors as currently catalogued.
04684
Pegs 43
This Price List has been prepared lor the convenience of. American-Standard distributor* and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices preval'
HH-4
CONVICTORS
;AMERiCAN-<Standard
HYDRONICHEATINQ
'MULTIFIN CONVECTORS
TYPE K -- STOCK MODEL -- TREE STANDSHS Expanded prices
For use on two-pipe steam and hot water systems only.
No. 4 depth (4Vi' cabinet)
IwtM
Mil
m * ffrw*
Tn4i frin
20* cabinet height
20 420-20 24 424-20 28 32 36 40 44 48 66 64
10.6 13.0
18 $15.34 20 16.30
No. 6 depth (6Vi' cabinet) sit h 1 Mffvs* Tra* M. 1 weifht Mm
No. 8 depth (8V4' cabinet)
wait aw.
vt4pHvt
tpKH. veiffcf
Trad* Mm
No. 10 depth (10Vi' cabinet)
all Me
mtpat
Uppta$ welfltf
Trade Mce
620-20 14.9 21 $17.06
624-20 18 4 24
18.46
.... ....
....
--
628-20 22.0 632-20 25.5
27 29
19.90 2130 832-20 31.7 33 $23.78
....
636-20 29.0 33
22.70 836-20 36.0 37
25.50 1036-20 45.5 42 *29.30
640-20 32.5 34
24.10 840-20 40.4 39
27.26 1040-20 51.2 48
31.56
644-20 36.1 37
25.54
648-20 39.6 40
26.94 848-20 49.2 46
30.78 1048-20 62.3 52
36.02
656-20 46.7 45
29.78 856-20 58.0 51
34.30 1056-20 73.4 58
40.46
664-20 53.6 52
32.62 864-20 66.9 59
37.86 1064-20 84.5 64
44.90
24' cabinet height
20 420-24 24 424-24 28 428-24 32 36 40 44 48 56 84
12.1 14.9 17.8
20 22 25
15.94 17.06 18.22
620-24 17.2 624-24 21.2 628-24 25.4 632-24 29.5 636-24 33.5 640-24 37.6 644-24 41.7 648-24 45.7 656-24 53.9 664-24 62.2
23 26 30 33 35 38 42 44 50 57
17.98 19.58 21.26 22.90 24.50 26.14 27.78 29.38 32.66 35.98
832-24 838-24 840-24
848-24 856-24 864-24
35.6 40.5 45.5
55.4 65.2 75.3
38 40 44
50 55 63
25.34 27.30 1036-24 29.30 1040-24
490 55.2
45 52
33.26 1048-24 37.18 1056-24 41.22 1084-24
67.1 79.0 91.0
62 64 71
30.70 33.18
37.94 42.70 47.50
32" cabinet height
20
620-32 18.7 29
18.58
24
624-32 23.1 32
20.34
28
628--32 27.7 36
22.18
32
632-32 32.1 40
23.94 832-32 40.9 45
27.46
36
638-32 36.5 43
25.70 836-32 46.5 48
29.70 1036-32 53.1 54
40
640-32 41.0 48
27.50 840-32 52.2 56
31.98 1040-32 59.5 59
44
644-32 45.4 56
29.26
48
648-32 49.8 58
31.02 848-32 63.6 65
36.54 1048-32 72.3 69
56
656-32 58.7 67
34.58 856-32 74.9 73
41.06 1056-32 85.1 76
64
664-32 67.8 71
38.22 864-32 B6.5 76
45.70 1064-32 97.9 84
Plugs and bushings are not regularly furnished with Multifln Convectors, but are available for separate sale at prices shown on page 37.
, Non: For stock model cabinet extras, see page 45.
Ordering Example:
l-K-636-32 Multifin.
.
33.10 35.86
41.22 46.58 51.98
HH-
Pag. <4
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable and distribution expense and do not purport to represent actual prices prevailing in any particular
Ame rican -Standard
HYDRONIC HEATING
CONVECTORS
CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS
CABINET EXTRAS--STOCK MODE1. MULTIFIN ONLY
Trade Met
1. Knob operated damper.................................. ..............................................................each
2. Metal trim strips: 20'to 36'long......................................................
each
40" to 64'long................................................ '...................................................... each
3. Snap-on inlet grille.......................................................................................................... each 4. Air chamber with extendedtube, manualvent......................................................each
5. Air chamber with Dole No. 20JRauto-vent.................................................. each
Note: Items also available for special service multifln.
$4.00
3.05 3,55 2.80 3.50 3.50
SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS
Trade Price
1. Knob Operated Dampers: (Standard Knob Type) For all types except Type "S".......................... each $4.00 For Type "S" only................................................each 4.20
Institutional damper (with Allen head screw flush with cabinet)
For all types except Type "S".......................... each 4.20 For Type "S" only................................................each 4.50
2. Access Doors (in standard locations 1. 2, 3, 4, 7 or 8 as shown in current literature)
Hinged type with slotted head cam operator .................................................................each
Hinged type with Allen head cam operator .................................................................each
4.00 4.80
Note: Access doors in other than standard location price on application
3. Special front fasteners (other than slotted head screws)
Phillips or Allen head screws............ per cabinet
Cam locks for"F"and "FG" (Multifln and Arco) Cam locks for "S" and "W" (Multifln only)
per cabinet
Cam locks for "FR," "FRG," "FRGB" and "PR," "PRG," "PRGB"........................ per cabinet
.35
7.20 9.60
4. Heavier gauge cabinets-Trade Price per sq. ft. of cabinet output:
Front Only Unors Only
No. 18 gauge.................... $ . .
$0.04
No. 16 gauge............................ 04 No. 14 gauge............................ 09
.06 .10
5. Insulation: (Furnished on outside of cabinet liner)
Back. Ends Back Only and Top
V4" Fibreglas.. per cabinet $5.80 $7.20 Vi" Celotex .. .per cabinet 5.80 7.20
6. Special stiffening angles: Angle spotwelded inside cabinet front per stiffener
1.00
Trada Price
7. Metal trim strips: For recessing Types "F" and "FG" Multifln
Convectors only
Catalogued heights and lengths up to 36". .each $3.05 Catalogued heights and lengths 40" to 64'.. each 3.55
Note: Any special height or length___ price on application
8. Sound deadening material (approximately %' thick)
Inside front panel only........................per cabinet 5.80
Inside complete cabinet......................per cabinet 7.20
9. Sealing strip for standard length "FR," "FRG" and "FRGB" cabinets only (Vi* x H" Polyeurethane) ......................................................... per cabinet
2.00
10. Snap-on inlet grille..............................................each For Types "F," "FS," "FR" and "PR" Multifln
Convectors only.
2.80
11. End Pockets (provides additional length for valve housing-specify right or left hand)
4" end pocket with No. 18 gauge vertical baffle per end pocket 2.90
6' end pocket with No. 18 gauge vertical baffle per end pocket 3.60
8" end pocket with No. 18 gauge vertical baffle per end pocket 3.60
End Pockets over 8', use 8~ end pocket price, plus $.60 per inch or fraction thereof.
12. Multifln front panels only: 35% of complete convector unit price (based on No. 6 depth)
13. Arco front panels only: 20% of complete convector unit price (based on No. 6 depth)
14. Multifln Cabinet only: (no element) 70% of complete convector unit price
15. Arco Cabinet only: (no element) 50% of complete convector unit price
16. Knockouts: Are optional-Fumished only on request-Price on ap plication.
Type cabinet
MINIMUM CABINET HEIGHTS WITH DAMPERS
Multifln
Arco Cast Iron
04686
F, FG W
FS, FSG S FR, FRG, FRGB PR, PRG, PRGB BF
20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 15" For #4 depth
24" For all depths 24" For all depths 24" For all depths 24" For#4, #6, #8 depths-32" For #10 depth 20" For all depths 20" For all depths Not Available
Cabinet heights shown for types W, S and BF are nominal heights, actual heights are 5" less. Cabinet heights for Arco Cast Iron convectors applicable to X-4 (underneath) connections only.
Page 45
This Price List has been prepared for the convenience of American-Standard distributors and their trade cus
tomers only. The trade prices shown represent fixed markups over distributor p
" '------------ -----
and distribution expense and do not purport to represent actual prices prev
HH-4
TERMS
American-Standard
HYDRONIC HEATING
TRADE PRICE BOOK
Illustrations and descriptions of Plate Numbers listed In this price book will be found In the current AmericanStandard Hydronlc Products Catalog and literature. Items Illustrated In product literature and not included In this price book are discontinued. The Illustrations in this price book although actual representations of certain product in the line, do not necessarily show sizes and details of all products in the line.
This book contains suggested Trade Prices for certain Hydronlc Heating products sold by American Radiator & Standard Sanitary Corporation ("American-Standard'') through its Plumbing and Heating Division. (AmericanStandard acting through that Division Is hereinafter referred to as the "Seller"). The Seller assumes no obligation to sell to anyone at any price any of the items listed herein.
This Price List has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribu tion expense and do not purport to represent actual prices prevailing in any particular market.
All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may
also, from time to time, discontinue without notice the sale of any of the products listed herein. ^
^
INVOICE MINIMUM
/T
An order for items included in this price book for which invoice prices aggregate less than $3.00 net will be billed at
$3.00.
TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY
AMERICAN-STANDARD THROUGH ITS PLUMBING AND HEATING DIVISION TO ITS DISTRIBUTORS
All sales of goods by American-Standard through its Plumbing and Heating Division are made subject to terms and conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions are as follows:
FRICI
Goods sold by the Seller will be billed to the Buyer according to the prices end terms contained in its current bulletins and pnce books. In the case of orders (or goods (or which no pnce is currently in effect, the price will be determined by the Seller and set forth in the invoice Issued after shipment of the goods.
Taxes. Any tax or other Government charge now or hereafter levied upon the production, sale, use or shipment of goods ordered or sold, will be charged to and paid for by the Buyer.
DEL1VKRY
Traaspertatioa Bisks. Delivery to the initial carrier shall constitute delivery to the Buyer. The Seller's responsibility ceases upon delivery in good order to such carrier, and all goods are shipped at the Buyer's risk.
The Buyer is urged to examine all deliveries carefully before signing transportation receipts, if goods are visibly damaged, the Buyer should insist that written confirmation of the damage be noted on the freight bill or dray ticket by the agent of the carrier. If damage is discovered after unpacking, the carrier should be notified at once, so that inspection can be made and the claimed damage substantiated by the curler.
laferfereaee with Delivery, The Seller has no obligation to deliver goods against any order until U has accepted the order by Issuance of its acknowledgment of order. In any event, the Seiler will not be liable for any delay or failure in the delivery or shipment of goods against an accepted order or for any damages suffered by reason thereof, when such delay or failure is. directly or indirectly, due to accident (in manufacture or otherwise). Are, flood, riot, war, embargo, labor stoppages. Inadequate transportation facilities, shortage of material or supplies, delay or default on the part of its vendors, regulation by Government authority, or any like or dissimilar cause or causes beyond its control.
WARRANTY
Except where a different express written warranty has been Issued with respect to putlcular products, no warranty, express or implied, is extended by the Seller to any person or persona other than its distributors and other direct Buyers. The Seller warrants only, and only to direct Buyers, that It will furnish by freight a replacement for, or at its option repair, any product of its manufacture or part or portion thereof, proved to its satisfaction to be defective in material or workmanship under normal use and service within one year after installation. The Seiler will not be responsible for any damages whatsoever, or for labor expense, In connec tion with such replacement or repair.
This warranty is in lieu of all other warranties, express or implied, and of all other obligations or liabilities, on the part of the Seller. The Seller neither assumes nor authorizes any other person to assume (or it any other liabilities in connection with the sale of Its products except in the case of express warranties which may be Issued by It in writing from time to time with respect to particular products.
Goods of other manufacturers sold by the Seller are not warranted except by express warranties which may be issued in writing from time to time, with respect to particular product! or particular tales, but the Seller will endeavor to secure (or its direct Buyers the benefits of war ranties extended by the manufacturers of such goods sold but not man ufactured by the Seller.
CONTRACT WITH BUYIR
Acceptance of Orders. Orders will be accepted only by the Seller's usual acknowledgment of order containing terms and conditions applicable thereto. No terms and conditions appearing in a Buyer's order that are at variance with the Seiler's terms and conditions shall be binding upon the Seiler unless specifically agreed to by it in writing. Unless the Seiler spe cifically so agrees in writing in acknowledging any order, any terms and conditions appearing in a Buyer s order contrary to those stated herein and in such acknowledgment of order are to be deemed waived by the Buyer. Receipt by the Buyer of the acknowledgment of order without prompt objection to the terms and conditions therein and herein set forth, constitutes acceptance by the Buyer of such terms and conditions.
Cancellation of Orders. After the Seller's acknowledgment of order has been issued, an order may be modified or cancelled only upon written agreement by the Seller. Orders for goods other than those of standard manufacture will not be cancelled after a commitment has been made or production scheduled.
Credit for Returned Goods. Merchandise may not be returned for credit unless the Seller has agreed to accept it. Where returns are accepted, a deduction of 10% will be made for rehandling. All transportation costs for returned goods must be paid by the Buyer. In any event, only salable merchandise of standard manufacture may be returned for credit.
Credit Approval. Buyers' orders are accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stopped in transit on accepted orders without any liability on the Seller's part. If. In its opinion, the Buyer s ability to pay for the merchandise on these terms and conditions is in doubt.
SHORTAGES OR VARIANCES
No claims for variances from or shortages In orders will be considered unless presented within 60 days after receipt of goods.
PRODUCT AND PACKAGING CHANGES
Factors beyond the control of the Seller and the need (or continuing improvement of product require the making of changes from time to time in products and their packaging. The right is reserved to make reasonable changes of any kind without notice and lo deliver revised designs or models of goods against any order, unless on the face of the acknowledgment of order this right is specifically waived.
The Seller shall have no responsibility whatever with respect to changes made by the manufacturer In products (or their packaging) sold but not manufactured by the Seller.
SHIPPING WEIGHTS
The shipping weights given herein are approximate, for Buyers' con venience only, and are not guaranteed.
HH-4
AMERICAN RADIATOR & STANDARD SANITARY CORPORATION
PLUMBING AND HEATING DIVISION
Page 46
04687
AMERiCAN-^Standard HYDRONIC PRODUCTS
MEMORANDUM
Pag 47
04688
HH-4
Am e rican ->t an dard
PLUMBING AND HEATING DIVISION
AMERICAN RADIATOR & STANDARD SANITARY CORPORATION
40 WEST 40TH STREET
NEW YORK, N.Y. 10018
04689
ho in U.S.A.