i -5- PART III: Construction, Alteration and Repair of a Structure 301. The spraying of asbestos-containing material is prohibited after March 31, 1972. 302. Non-asbestos fibrous matter shall not be sprayed in an area open to the atmosphere unless the following procedures are taken: (a) The entire floor or area to be sprayed shall be enclosed with plastic or plastic-coated tarpaulins in a manner which shall preclude the escape of fibercontaining material from the enclosure. All interior open areas such as elevator shafts and stairwells shall be enclosed in a manner which shall prevent the escape of fiber-containing material from the working area. (b) The entire sprayed area, all ledges and surfaces including tarpaulins within the enclosure shall be thoroughly vacuumed upon completion of the spraying operation and immediately before the enclosure is dismantled. ( 303. (a) Tne cuttiny, trimming, fitting or stripping of asbestos-containing material in the construction, alteration or repair of a structure which is done at the site of such structure in an area open to the atmosphere shall be conducted within a special en closure designed to preclude the escape of asbestos fiber from the immediate area of such enclosure. (b) The mechanical exhaustion of dust from such enclosure to the ambient air is prohibited unless such exhaust system is equipped with a properly sized fabric filter for dust collection or an equivalent device as approved by the Agency. 304. Compliance with Sections 302 and 303 notwithstanding, visible emissions of fiber-containing material in an area open to the atmosphere shall be considered a violation. 305. Asbestos-containing material applied in the construction, alteration or repair of a structure shall be coated with a sealant, provided with a cover or installed, in some other manner so as to preclude emission of the asbestos-containing material to the circulating air. Any plenum or other structure coated with or containing asbestos-containing insulation and used in the circulation of air in a building shall be thoroughly cleaned of all debris and waste insulation.