Document 99NqeNq074z9qaEJOvjaXNOX5
ABDOO167749
VCM EXPOSURE TRAINING TEST, 1981
ddli//A) 6M
NAME
DEPARTMENT
DATE
1. The eight-hour exposure limit for VCM is
j parts per miLlion (average).
2. The 15-minute exposure limit for VCM is\^y /$
parts per million (average).
3. You are required to wear an approved respirator in VCM concentrations above:
1.0 ppm b. 0.5 ppm c. 10.0 ppm d. 5.0 ppm
4. VCM is not a fire hazard.
5. Exposure to high levels of VCM over long periods of time may cause liver cancer and chromosome damage.
True True
X False
False
6. If you can't smell any VCM, you can be sure that there is not enough around to hurt you.
7. VCM is a colorless gas at normal temperature and pressure.
8. Breathing the smoke from burning VCM can cause severe lung damage or death.
True >< True
X True
X False
False
False
9. Indicators of VCM leaks include "icing" and "hissing" sounds from processing equipment.
X True
False
10. You must stay out of VCM regulated areas except when you have a reason to enter them because of your work.
True
False
11. Our Honeywell continuous monitors alarm when '*&*'*- 7 ppm is detected in an area.
12. The VCM regulated areas in the plant are: (Circle a, b, c, or d)
a. The old reactor area and the VCM tank farm
b. The VCM compressor shed and the tops of the large slurry blend tanks
/jT!^ The two vinyl reactor areas, the tops of the large slurry blend tanks, the VCM
compresser shed, and the tops of VCM tank cars.
d. The VCM storage sphere, the recovery areas in both vinyl units, the tops of VCM tank cars, and the east half of the plasticizer tank farm.
13. You must wear protective clothing when doing any job where your skin might come in contact with liquid VCM.
14. Any part of the body which is exposed to liquid VCM may be quickly and severely frostbiten.
15. When a VCM emergency begins, all plant workers not directly involved with handling the situation should immediately assemble in a group just north of the guardhouse.
X True X True
V True
False False False
TEST CONTINUED ON BACK
ABDOO167750
16. VCM cannister masks may be used in VCM concentrations below 10 ppm for up to 10 hours. They must not be used in higher concentrations except to escape from danger.
17. Air-line respirators may be used in VCM concentrations of no more than 1000 ppm. They must not be used in unknown concentrations.
18. Scott Air Paks must be worn in VCM concentrations above 1000 ppm. They must also be worn in unknown'concentrations.
19. Breathing high concentrations of VCM can cause you to pass out.
20. One of the purposes of the medical surveillance program is to detect the symptoms of VCM related illness as early as possible.
True
True
True
V True
\/ ' True
False False False False False