Document 99KQV6G7jwzq4VrXEK3y9jQd6

1HI XITHMN* UkBORATONY COkktOI OP MEDICI NC--CDKN AVENUE CINCINNATI 10. ONIO UNIVERSITY OF CINCINNATI OCPAATMIHT OP pfttVCNVIVI MEDIC1NI AND INDUATMAL NIALTH C*U ADOAEMi KCTLAfe. CINCINNATI TELEPHONE: CApitoi Ut4 September 25, 1956 Mr. Elmer P. Wheeler Industrial Hygienist Monsanto Chemical Co'. 1700 S. Second Street St. Louis l.|, Missouri " ' Dear Elmer: Thanks for returning the copy of the Cordon Conference talk, which I want to send to Phil to look over before I attempt to put it In shape for publication. X shall be pled to loan it and the slides to you whenever you wish. In relation to the determination of Aroclor 121:2 in the atmosphere of the submarine^ you are correct that if a standard UV curve were prepared for either Aroclor or the di-2-ethylhexyl phosphate and a sample of air containing both of these was analyzed for one or the other, that high results might be obtained because of Interference by the other substance. How ever, if a standard UV curve were prepared from Pydraul F-150 and if the composition of the material in the air were not any different than that in the liquid state then a reasonable concentration of Pydraul F-150 would be determined and the concentra tion of Aroclor could be related to that concentration. This of course Involves the divulgence of the compo sition and may not be desirable. Other objections to this method are (l)that it is not too specific since a peak of maximum absorption-might not be present above 230 or 2J0 m/u, and (2)any other organic vapors present in air that absorb at the selected wave length would also give high results from inter- , ference, MUMS 090966 Bap;e 2 Mr. Elmer P. Wheeler September 2b, 1956 Two other indirect methods that mip,ht be more specific would be to determine the Santlcizer llil by one of two methods ((1)Hydrnlyve and determine the phenol by couolinp with diazotized para nitroaniline or (2)Hydrolyze and determine the phosphate as ammoniumphosphomolybdate). Either one of these methods woyld be fairly soeclfic and fairly sensi tive. I would prefer either of them over a UV method of the Santlcizer based on the UV absorption due to the phenyl radicals. This of course also divulres the compositions. The only way to analyse the atmosphere for Aroclor 12l|2 without revealing the composition is bv direct, analysis for the Aroclor. 1 do net know of sny satisfactory wav of directly determining the Ai'oclor except by the UV method or for the cnloride. The UV, if based on a standard curve for Aroclor, mlrht rive greater Interference (as mentioned earlier) than the lnterferenoo from extraneous chlorides by the method of thermal decomposition and precipitation as silver chloride. At the moment I can not think of any medln that would remove the extraneous chloride before thermal decomposition that mipht not also remove some or part of the Aroclor. Tf Aroclor 121(2 was not removed from scrub! inr through a Weak aqueous alkaline solution, then the extraneous chlorides could be removed before thermal decomposition of Aroclor. However, 1 believe the probability is low that, this would be absol"t.e with tho low concentrations of Aroclor in the air arid -nlyht riven significantly low results. If the Aroclor were completely removed by the alkaline solution and could then be removed bv aeration, (the extraneous chlorides would remain behind) a satisfactory method would be available without revealinr the composition. However there are probably too many "ifs" in this procedure, Because of the apparent Impasse of a rood method of annlysis without revealinr: the composition, I have looked arain at the UV absorption curves for Aroclor 12l'8 (I don't have the comparable one for Aroclor 12)j2) in rirure 6 of the report of MQNS 090867 Pape 3 Mr. timer P. Wheeler September 25, 1956 March 11, 1953 on Pydraul F-9 and for Santlcizer lltl In Figure 3 of the report of October 111, 19l|9 TM Santlcizer 1J|1 . These data hold some hope that the 1 nterference of the S-ll|l by UV at Zb, 6 m/u mieht not be two preat. In the determination of Arorlor 12h2. This should be checked by running known solution of Pydraul P'-ISO and Aroclor 12!'? in the UV to determine the extent of interference. This is not too difficult or too extensive If you wish us to check It for you. Sincere]y yours, .TFT; fk Treon MOWS 090868