CHAPTER 36
1965 Guide And Data Book
Automatic dry filters which utilize a web-like material sup plied in roll form are-available. While generally not recom mended for the handling of atmospheric dust, they are par ticularly suitable for the removal of lint associated with operation of textile mills and dry cleaning establishments and for collection of ink mist resulting from press room operation.
Charged-Media Electronic Air Cleaners
The charged-media type air cleaner consists of a dialectrio filtering medium, usually arranged in pleats as in typical dry filters. No Ionization mean" are employed. The dielectric fiI- tering medium' may consist of glass fiber mat, cellulose mat,* or other wimilar material, and is supported on or in contact with a gridwork consisting of alternately grounded and charged members) the latter usually being held at a potential of. 12,000 volts d-c. An intense and non-uniform' electrostatic field is thus created through the dielectric medium. Airborne particles approaching the field are polarised and drawn to ward filaments or fibers of the media. The general arrange-, ment illustrating this type of filter is shown in fig. 3. '*
;The precipitator of this type offers resistance to ah''flow, when clean, on the order of 0.10 in. of water at 250 fpm veloc ity and, unlike the ionising type, the resistance of the chargedmedia type electronic cleaner rises as dust is aecumulated'on the media. Because of these characteristics the filter tends to equalize.tite air'distribution over the face of the filter, like typical replaceable-media mechanical filters, the charged-me dia precipitator is serviced by replacing the filtering medium. The dielectric properties of the media are impaired when the relative humidity exceeds 70 percent.
RELATIVE PERFORMANCE OF DIFFERENT TYPES OF FILTERS
Group I--Viscous Impingement, Unit of Panel Type
In this type of flat, shallow filter assembly, the approach velocity of the air stream equals the velocity through -the filter media. The filter media is characterized by high porosity, high dust-holding capacity, relatively low efficiency, and low cost. Thickness ranges mostly from $ to 4 in.
This class includes filters of the permanent washable type or of the disposable type, both of which are usually coated with oil for dust retention. The filter media-may include metal screen, crimped or corrugated in.various-ways; de formed perforated metal sheet in multiple layers; netted.wire
or other metal filaments, and other matted metal filamentous configurations; relatively coarse glass fibers (15 to 60 micron diameters); animal hair; cellulose; and synthetic fibers, i.^ Dynel, Dacron and Nylon.
Initial resistance at the common ratings of 800 and 1200
cfm (20 X 20 in.) range from Q.02 in. for the thinnest to about 0.20 in. for the thickest, filters of this group are usually
operated to a final resistance of 0.4 to 0.6 in. of water. Average performance of some types of filters in this group when oper ated within rated limits is given in the following tabulation:
Thickness, Inch*1*
(Approx.)
Weight
Efficiency,* Percent
ATI Code
Dust-Holding Capacity,* .
Gnuns/1000 cfm Rated Air Flow
Dust Spot
Efficiency, Percent
(Atmosphere)*
<1 l-lH
1%-2H 2>f4
20-50 50-75 60-80
70-85
70-140
120-360 180-640 240-760
5-10 5-15
5-20
10-25.-
By AFI Tat Code, Section 1 (1953) * By AFI Duet Spot Test Code (i960).1
Group II--Extended Surface, Dry Type, Medium Efficiency Filters
This class includes extended surface panel or cartridge units of pleated or deep-folded configuration, wherein the approach velocity of the air stream is substantially greater than the velocity through the filter media, i.e., the filter area is much greater than the surface area. Media filtration velocities range from 30 to 90 fpm, although approach ve locity is usually around 250 to 625 fpm. Depth in direction of air flow of this group is under*.12 in.
Filter media include those of fine glass fibers, 6 to 20 microns in diameter, in mat form up to in. thick; thin paper-like, nonwoven mats of fine glass fibers, cellulose, or cotton wadding; wool felt; synthetic sponge or foam having a resilient structure of interconnecting pores; and nonwoven mats of comparatively large diameter fibers (more than 30 microns) of varying thicknesses up to 1 in.
Media of lowest efficiency and highest dust-holding ca pacity include the'coarser foams and nonwoven mats of large diameter fibers. Those having higher efficiency and lower dust-holding capacity are thin, paper-like mats of fine"glass; cellulose, felt, etc.
In some instances, a dust adhesive is applied to media in
Rg. 3 . Cross-Section Diagram of Charged Media Type Bectronk Air Qedner ;
Air Cleaners
623
this group to enhance dust colksction and retehtibnl Initial resistance of this group; at rated air flow, fies'ffibstiy between 0 05 and 0.25 in. of water. They are usually operitedtb a final resistance of 0.5'to 0.7 in. of water. Average performance of some types of filters in this group When'operated Within rated
limits, is given inthe following tabulation:
filter Media Types
. Wt Efficiency,*
Percent
xM.&xtb' ;
DmfcHokfiag Capacity)*.
Grams/1000 cfm Rated Air Flow
Dust Spot
Efficiency, Percent
(Atmosphere)*
Coarse foam and large fibered nonwovens
Finer poted foams and finer fibered nonwoVena
Thin, paper-hke mats of gods fibers, cellulose
Matsoffihe^tOss fiber, tmdti-ply
felt
55-65
70-80
awft
85-95
360-720 180-360 OO-lSO
90-180
5-15 . 10-25
20-30 25-40
By 'AFI-Ted Code, Section 1 (1953).* * By API Dust Spot Test Code (i960).*
Group ilH-Extended Surface, -Dry Type, 'High
Efficiency Filters
' Physical Characteristics 6f these'filters afeaimilar to Group II except that their lower`porosity and ultra^fine fiber'cdtnpotitidn'reqxufe'nd'olil1 for'dust`retention. 'They are 'alTof the disposable' type ah'd are characterized 'by TelativblyJujjlier efficiency.' Media filtration Velocities usually*range' from 15`to 3) fpm, h'pproach' velocities from 250 to'625 fpm.Depth- in direction of air ftow'of filters* ranges'fromT2 to 36in. .
Initial redstanceof fillers, at rated air"flowranges.generally from 0.10 to 0.50`m. They'are usually operate! to a final resistance of 0.6 to 1.0 in. W.G. Average .performance of some types of filters/ when operated within rate! limits, is given " in the following' tabulation:
Filter Media'Typfea
AFICode j Dust-Holding
'Capacity,
GramzyiObo Cfm Rated Air Flow
DdStSpbt - Efficiency,
Percent :
(Atmosphere)*
Mats of 5 to 10 inicron fibers, Vi to H in. thfcfrfftsa
Mats of fibers so'mewhat'fiher
than above, 'or -t>f--gre5it4rthlckaess-
Mata Of 1 to 4' nfucrbn fibers;
mixtureOf various fiberaind
: asbestos
Mats of-Hto.2 micnjh fiber*:usually^glass-fibers
270-540'
'180-450 ISCKJ60 90-270- .
40-60 70-80
'804)0 90-98
Tai['Co3e .tl960).* Weight efficiency,, in
5?? high nineties,4b `TihnaisCrimin&ling, hence inappropriate f6r
.thisClass of filta.
.
K
.Group IV-;--Viscous Impingement, Moving Curtain
Type :
/
.--.^te'pann&neni):metal paaertype bf rhOvihg Curtkin filterIs Qshally designed' Rir ah3!of>eraB^ati'5dO 'fpha^fakfe^elacityit
-a resistance of O.4to'0.5 in. of water. Dust-holding capacity is not a critical factor in performance rating as1the metallic medium is autoni&tic&Uy cleaned,' usually by passage through an oil bath. Efficiency or arrestance values offered by the permanent moving curtain type media, usually arranged so that the air stream passes through two'curtains, range gen erally from 75 to 85'percent by the AFI weight procedure. `Dust spot efficiency, atmosphere, is generally in the 10 to*25 -percent range.
The moving curtain filter with replaceable* media, usually in roll form, is also usually designed for and operated at 500 fpm face velocity. Initial resistance generally ranges from 0.12 to 0.25 in. of water. Under operating conditions, steady state resistance ranges generally from 6.3 to 0.6 in. of water. Yarious types and thicknesses of media are used; the usual thick nesses range from 1% to 2% in.
Both dust-holding capacity and arrestance are critical fac tors in performance 'ratings. A modification of the AFI weight method is commonly used for obtaining performance data. This modification pertains to moving of the curtain in the test air stream when resistance reaches prescribed levels, usually 0.4 to 0.5 in. of water, and continuing dust feeding until several face loadings of curtain'have been used. Effi ciency values are obtained at regular intervals'during dust loading to establish steady state efficiency values. "Dust-re ceived values, established on the Basis of steady state condi tions, are usually expressed in grams per sq ft of media used. 'Dust-holding capacity for the AFI weight .procedure is ob' tained by multiplying weight of dust received by steady state efficiency.
Under steady state conditions, efficiency by the modified AFI weight method for the various media commonly used is ; generally in the 70 to 85 percent range. Dust-holding capacity by the Weight method, AFI dust, ranges generally from 50 to 150 grams peraq ft. All values are'based on the conditions of ' test described above.
'Group V--Electronic (Ionizing Type) Air'Cleaner1
Electronic air cleaners use electrostatic precipitation prin ciples to collect particulate matter (see Fig. 4)'but operate on much lower voltages than the type commonly used on in dustrial-stacks. The designation Electronic Air Gleaner has been standardized to distinguish the das of electrostatic pre cipitator which-alenels suitable for cleaning ventilating air.
in a typical case, a potential of 12,000 volts may- be -used to .-create the ionizing-field, and some'6000 volts between the `plates upon which the-precipitation of dust occurs. These
voltages, which are capable of momentary shock to person nel similar to that of a spark plug, necessitate some safely measures. A typical arrangement provides means for making the'equipment Inoperative when any door affording access * to high-voltage'parte is opened. Operation can be resumed only after all 'doors'are closed.-The voltages necessary for operation 'of the equipment are usually obtained by of high-voltage direct-current power packs operating from a 110-120 volt, 60-cycle, single-phase building service. Electric power consumption is about 12' to 15 watts per 1000 cfm, plus the approximately 40 watts required to energize the rectifier tube heaters.
Air cleaners of this type offer negligible resistance to air 'flow and,`"therefore, care must'be-exercised in arranging the "duct approaches on the entering and leaving rides of tiie cleaners In order that 'the air flow may be distributed uni
formly over the cross-sectional area. The efficient of the 'eJefctWnic"air cleaner'-is sensitive to air velocity,-arid the devitS ltSfelf hSk'much le&Tenciehcy 16 redtffy the air`stream