Heating Systems Specialties
Armstrong Machine Works
851 Maple Street, Three Rivers, Mich.
Steam Traps . . . Air Traps . . . Humidifiers High Side Floats . . . Refrigerant Purgers
Representatives in Principal
Centers
ARMSTRONG INVERTED BUCKET STEAM TRAPS
Armstrong offers a complete line of traps for draining low and high pressure steam headers, pipe coil radiation, unit heaters, air conditioning equipment, process equipment, etc., to gravity or vacuum return systems.
Automatic Air Discharge. Standard
traps automatically discharge normal amounts of air along with condensate. Where large amounts of air must be
vented quickly when steam is first turned on, Armstrong BLAST Traps with
thermic bucket vents are recommended. Air handling capacity ranges from 500 to 1500 cu ft free air per hour.
NEW! Traps with integral strainers save fittings, labor. No. 880 with same capacity as No.
800listed belowis$11.50. No.881 with same capacity as No.811 is
$16.00. Both cost less than traps plus separate strainers.
No. 800-815
No. S11-Z16
No. 880-881
Side Inlet Traps
Pipe Connections............................. List Price (Regular)........................ List Price (Blast Trap).................. Telegraph Code (Regular)........... Telegraph Code (Blast Trap)--
Diameter of Bolts............................
Continuous _ dis charge capacity in
lb of water per hour at pressure indi cated. For more complete informa
tion see the Capa city Chart in Arm strong Steam Trap
Book.
3 1
Bottom Inlet Traps
5 10
15 20 30 50
70
100 125 150
200 250
Maximum Pressure, lb.................
No. 800 No. 811 No. 812 No. 813 CAPACITIES, PRICES
W or *' H' or
$10.00 $14.00
K' or
$23.00
Hr or 1'
DIMENSIONS
$31.00 Note that capacities of*
$12.00 Aloe Aloette
$16.00 $26.00 $34.00 No. 811, 812 and 813 Brown Cherry Dawn traps are the same as Brownette Cherette Dawnette No. 211,212 and 213 re
5H' 5'
6
y<
5 lbs.
150
6H' 5'
6
*6'
6 lbs.
250
896'
6*4' 6
*4' 15 lbs.
250
UK'
6 *4' 27 lbs. 250
spectively. On most in stallations , the engineer therefore has a choice of side inlet--side outlet or bottom inlet--topoutlet 0 oay styi es.
450
830
1600
2900
4800
7600
- 14500
5G0
640 690 500 580 660 640 680 570
950 1060
880 1000 840
950
860 950 810
860 760
1900 2100
1800 2050 1000 2200 1800 2000
1500 1600 1300
3500
3900 3500 4000 4100 3800
3600 3900 3500
3200 3500
5800 6500 6000
6800 6300
6000 6200
6700 5700 5300
5700
9000 10000 8500
9800
9000 9200 10400 10900
9500
9200 7000
17300
19200 18500 18000 18200 -
16300 18000
20000 _ 18500
17500 19000
No. 211 No. 212 No. 213 No. 214 No. 215 No. 216
*4'
$13.00 $15.00
6H' 4H'
*6' 6 61b 250
14' or Vk $21.00
$23.00 Birch
Birette
sr
5'
*6' 8 12 lb
' 250
>4' or H'
1' or 1*4' 1*5' or V
$29.00 $41.00 $55.00 $78.00
$32.00 $44.50
Walnut Hemlock Larch Tamarack
Walette Hemlette Larette Tamrctte
1U6& M' 6
12*4'
7*4' H' 8
14' 8*4'
*4'
8
16*4 10*6'
>4'-
21 lb
34>4 lb 47 lb
78 lb
250 250
250
1378
Armstrong Machine Works
Heating Systems Specialties
High Capacity,. Compact Size. The high leverage of the patented free-float ing lever makes it possible to open dis charge orifices which are very large for over-all trap size.
Positive Action. The discharge valve is either wide open or closed tight. Fast opening and closing prevent wire-drawing.
Seif-Cleaning. Swirling action of con densate during discharge carries dirt
through trap. There are no dead spots for dirt to collect.
High Quality. 18-8 stainless interior arts. Valve and seat are chrome steel, ardened, ground and lapped. Low pressure trap parts same material and quality as those used for 1500 psi, 900 F. Armstrong Steam Trap Book. 36 pages of data on traps, selection, instal
lation and maintenance. A usable hand book for any engineer dealing with traps. Free copy on request.
TRAPS FOR UNIT HEATERS
Armstrong inverted bucket steam traps are particu larly suitable for draining low or high pressure unit heaters to vacuum or gravity return systems for the following reasons:
1. Air and CO* are vented automatically every time A the trap opens--this keeps heaters hot, helps pre? vent corrosion.
2. Condensate is discharged at steam temperature as rapidly as it accumulates--keeping heaters at max imum temperatures.
3. Leakage of steam through an Armstrong trap in proper working condition is impossible... no
' build-up of back pressure in return lines. 4. The dependability of Armstrong traps is outstand
ing--they seldom require maintenance. A New Bulletin containing Btu output figures for 24
makes of unit heaters explains fully how to select traps for this service. A valuable^compilation that is available to anyone upon request.
ARMSTRONG STEAM HUMIDIFIERS
For Stores, Offices, Hospitals, Factories, Laboratories
Operation. These units provide auto matic, closely con trolled humidification by - introduction of steam directly into the atmosphere. In stallation is compara ble to that of unit "heaters. Steam at 15
psi or less is required. A solenoid discharge valve on the hu midifier is controlled by a sensitive humidistat. A fan mounted on the humidifier'aids in steam dispersal, or a venturi nozzle can be supplied. Where an electric spark might represent an ex plosion hazard, compressed air operated models are available. In addition to the unit humidifier illustrated, there is a large model for installation in large air ducts and central heating systems. Capacities range from 31 to 630 lbs of steam per hour.
Advantages. Installation cost of Arm strong Humidifiers is as much as 80 per cent less than.some types of equipment.
The small C-2 unit lists at $182.25 com
plete with fan and motor, humidistat, strainer and steam trap. Operation, us ing steam at around $1.00 per ton, is economical. There is no extra load on the'heating system. No dripping--any moisture in the steam is re-evaporated in the steam-jacketed separating cham
ber. Control is accurate within a few per cent R. H.
Bulletin No. 1772 gives complete data on required relative humidities, selec tion .and installation of Humidifiers.
All Armstrong products are sold on a basis of satisfaction or your money back.