July 6, 1970
ttr. Garllngton Wilburn Manager, Engineering Westinghouse E lectric Corporation South Boston, V irginia Bear Gary* 1 have read your Process Specification 891**OGA "Disposition o f Scrap Inerteen and Inertcen Contaminated Materials'* and I found i t an excellent document which re fle c ts Westinghouse's concern about the PCB problem and i s a major step forward toward Improved control, I do have one concern th a t I would lik e to pass cn to you. The suggestion to burn solvent o r o il contaminated with Inerteen does not re fe r to any minimum combustion temperature. As we discussed previously, to ta l destruction of PCB's can only occur above 8Q0C, Any temperature below th is minimum w ill re s u lt in vaporization with release to the atmosphere o r worse yet, i t i s possible to p a rtia lly oxidize PCS'a in to m aterials which can be highly toxic (e .g . dioxins or furans). Your incineration should be thoroughly reviewed, I found our discussion and plant tour l a s t week very in terestin g and inform ative. Your plant has excellent housekeeping and with continued errsphasia on controlling lo ss o f PCB'a to the a i r and sewer, I am confident you can succeed in achieving a "bone dry" plant in which the leakage, s p ills , e tc . are a rarity, I am working with our P.R. Department on a suggested press release which I w ill send you soon.
Sincerely,
DSW 170506
d R Cnnhnm
W. B. Pepageorge, Manager Environm ental C ontrol