May 28, 1970
PCB ANALYSIS OF WATER SAMPLES, CENTRAL FOUNDRY PLANT - BEDFORD, INDIANA
cc: W. B. Papageorge - GO E. P. Wheeler/J. T. Garrett - GO R. E. Keller - Res. 1 W. R. Richard - GO
TO : n. t. Johnson General Offices
The EC/GC analysis of this second set of settling pond water samples confirmed our earlier results (Memo, NTJ, 2-2-70). The EC chromatogram of the effluent samples from Pond #5 (6A, B), as before, were not identical to either Aroclor 1242 or 1248 but rather like a mixture of the two. This alteration can probably be attributed to some biological or physical phenomenon occurring in the ponds.
The EC chromatograms of all other samples (from Ponds 1-4)
were equivalent to that of production Aroclor 1242 in every
respect.
The variable results obtained for the duplicate (?) samples is not readily explainable. I have included selected chromato grams for your reference.
OR Log Number
235 236 237 238 239 240 241 242 243 244 245 246
Sample Number
1-A 1-B 2-A 2-B 3-A 3-B 4-A 4-B 5-A 5-B 6-A 6-B
Sampling Point
ppm PCB as Aroclor
Pond #1 Pond #1 Pond #2 Pond #2 Pond #3
Pond #3 Pond #4 Pond #4 Pond #4 Effluent Pond 04 Effluent Pond #5 Effluent Pond #5 Effluent
3.90 630 24.2 19.3 14.3 6.6 2.6 2.0 4.7 2.8 1.1 1.9