Air Conditioning and Heating Piping HSSjftungs
Aeroquip Corporation, Jackson, Michigan
1
&
^\eroquip
AEROQUIP SELF-SEALING
COUPLING FOR "FREON i
12" AND "FREON 22"
M W.
This new coupling for "Freon 12" and "Freon 22" applications is finding wide use for all refrigeration and air-condi tioning applications. Convenient connec tion and disconnection without loss of refrigerant or inclusion of air and mois ture. Simplifies production and charging
and testing of equipment and permits shipping of factory charged units for easy field installation. Rapid assembly in equipment by means of sweat-type adapters and mounting flanges. Sizes through 1J in. O.D. tube size.
AEROQUIP 1540 HOSE FOR "FREON 12" APPLICATIONS
Dash Size
4 6 8. 10 12 16 20 24 32 40 48
O.D. Tube Size
H H
a n
?4 1
1>4 2 2H 3
Min. Operating Min.
Burst Pressure Bend
Pressure psi
Radius
2000 350
3
2000 20C0
350 350
4
m
2000 350 1400 350 1400 350
m m
1400 350
9
1400 350 11
1200 350 13J4
700 175 24
700 175 33
Aeroquip 1540 hose and reusable fittings are designed for refrigerating and air conditioning systems using "Freon 12." Aeroquip flexible hose lines can. be in stalled easily, even in confined areas, withstand compressor vibration and re duce noise. Ease of assembly makes Aeroquip hose and fittings ideal for en gineering mockups and production mod els. Available in sizes from in. to 3 in. Operating pressures up to 350 psi; temperature range --40 F to +170 F.
1312
Pipe and Tube
Air Conditioning and Heating Piping
COPPER AND BRASS INCORPORATED
Executiveoffioe: 230 Park Avenue, New York 17, N. Y.
HILLS--Baltimore, Md.; Brooklyn, N. Y.; Chicago, Clinton, and Joliet, III.; Detroit, Mica.; Loa Angeles and Riverside, Calif.; New Bedford, Mass.; Newport, Ark.; Rome, N. Y. DISTRICT SALES OFFICES--Atlanta, Ga.; Boston, Mass.; Buffalo, N. Y.; Cincinnati, Ohio; Cleveland Ohio; Dallas, Tex.; Dayton, Ohio; Grand Rapids, Mich.; Hartford, Conn.; Houston, Tex.; Indianapolis, Ind.; Miami, Fla.; Milwaukee, Wis.; Minneapolis, Minn.; New York, N. Y.; Philadelphia, Pa.; Pittsburgh, Pa.; Providence, R. I.; Rochester, N. Y.; St. Louis, Mo.; San Fran cisco, Calif.; Seattle, Wash.
TUBE AND PIPE FOR GENERAL CONSTRUCTION
Revere produces a wide range of Pipe and Tube for various industrial uses including condensers, aftercoolers and similar heat exchangers.
The services of Revere Technical Ad visors are available without obligation to assist Engineers, Designers and Con tractors in the selection of suitable Revere products for various' appli cations.
REVERE COPPER WATER TUBE
For: Hot and cold water service lines Underground systems for water, oil
or gas Drainage line and soil pipe Fuel oil and compressed air lines Heating systems--hot water and steam Radiant Panel Heating (technical book
let, "Design Procedure and Installation Practices for Radiant Panel Heating" available upon request).
LENGTHS, TEMPERS AND OPERATING PRESSURES
Type K K L L M
Temper
Hard Soft Hard Soft Hard
Pressure Standard Lengths Pounds Straight Coils
up to 400 12 and 20 ft " " 250 " " " 250
" 150 " " " 250 "
--
60 ft
--
60 ft
--
STANDARD DIMENSIONS AND WEIGHTS
TypeK
Type L Type M
all Thick ness In.
t Lb
per F t all Thick ness In.
t Lb
per F t
t Lb
per F t
Size
: in 5 In. d o
J
O & s & s
H .375 .035 .145 .030 .126 H .500 .049 .269 .035 .198 .025 .145
.625 .049 .344 .040 .285 .028 .204
.750 .049 .418 .042 .362 H .875 .065 .641 .045 .455 .032 .328
1
m
1.125 .065 1.375 .065
.839 .050 .655 .035 1.04 .055 .884 .042
.465 .683
1W 1.625 .072 1.36 .060 1.14 .049 .940
2 2.125 .083 2.06 .070 1.75 .058 1.46
2.625 .095 2.g3 .080 2.48 .065 2.03
3 3 >4
3.125 .109 3.625 .120
4.00 5.12
.090 .100
3.33 4.29
.072 .083
2.68 3.58
4 5 6
4.125 .134 6.51 .110 5.38 .095 4.66 5.125 .160 9.67 .125 7.61 .109 6.66 6.125 .192 13.9 .140 10.2 .122 8.92
Revere Copper Water Tube does not rust. It is smooth inside and out, easy to install and bends and flares readily. There is no thread cutting; it takes solder or compression type fittings.
Specifications:
Federal: WW-T-799 ASTM; B88
REVERE DRYSEAL COPPER TUBE
For: Air conditioning and refrigeration sys
tems General service work
Revere Dryseal Copper Tube is de hydrated and sealed at the factory be fore packaging. It is soft and flexible and when flared for compression fittings, it does not split on the ends. Its ability to take smooth hand bends virtually elimi nates the need for fittings.
50 ft. coils in sizes from } in. to % in. O.D., with wall thicknesses from .030 in. to .035 in., are packed in individual cartons.
REVERE RED BRASS & COPPER PIPE
For use when threaded pipe is required. Both are manufactured in standard
pipe sizes--hence can be used with
standard threaded or silver brazed fittings. Because of their extraordinary
resistance to corrosion, they function with unimpaired efficiency even after
many years of normal service.
Specifications:
Revere Red Brass Pipe meets the fol
lowing specifications:
Federal Standard: WW-P-351, Grade
"A"
Navy Department: 44P12, Grade "A"
ASTM:
B43 (Red Brass)
Revere Copper Pipe meets the following
specifications:
Federal Standard: WW-P-377
Navy Department: 44P2
ASTM: .
B42