^FOgpy PONT USE ONLY
DATE December 30, 1975
TEST AUTHORIZATION NO. TA-C- 75~1192 AND CONCLUSION
OFFICIAL PRODUCT NAME
"Lithosol" Red 4B Acid
PRODUCT CODE NO.
*159 200
POUNDS PRODUCT PROPOSED .
AREA _
Intermediates West
BUILDING NAME
DMA
TITLE AMEND THE CHAMBERS WORKS PROCESS TO REDUCE THE TIME TO
ADD SULFURIC ACID IN THE PRECIPITATION TUB___________
PREPARED BY: R. D. Alaburda
RESPONSIBLE FOR TEST , AND TEST CONCLUSION: -
R. D. Alaburda
pur po se o f t est :
To amend the Chambers Work^ Process to reduce the time to add Sulfuric Acid to the precipitation tub from one and one-half to two and one-half hours to three-quarters to one and one-half hours.
DURATION OF TEST:
s t an d ar d in v o l v ed :
Chambers Works Process by R. D. Gano dated
August 6, 197**.
ANALYTICAL CONTROL OR SPECIFICATIONS: [XI No change
[ 3 Change described under Test Details
PROCESS HAZARDS REVIEW: [] Required before test
&] Not required
MATERIAL SAFETY DATA SHEET: [] Revision required K] No change
PACKAGING AND SHIPPING CLASSIFICATIONS: [] Revision required IX! No change
TECHNICAL BASIS FOR CHANGE:
See Attached
TEST DETAILS: (Include Safety and Waste Disposal)
SAFETY:
No change
WASTE DISPOSAL:
No change
d is t r ibu t io n :
Jackson Lab. Files J. V. Flynn, Adm. Bldg. E. J. Fritz, Int. West (3) C. H. Lake, Bldg. 588 T. E. Lewis, G.A.L.
. J. Meyer, D & C Bldg. . S. Moores, Azo Lab. . Putnam, G.A.L. (3) R. F. Stalzer, G.A.L. P. Hi Weinberg, Int. West
NOT REQUIRED
MANUFACTUR in s ma n a g e r *
NOT REQUIRED
t e c h n ic a l d iv is io n *
DATE
NOT REQUIRED
PLANT MANAGER*
Page Two December 30, 1975 Test Authorization and Conclusion TA-C-75-1192 "Lithosol" Red >iB Acid R. D. Alaburda
TECHNICAL BASIS FOR CHANGE
The Process states In Step 13 that:
13. Discontinue heating the solution and slowly add sulfuric acid to the solution until the pH Is in the range of 1.5 to 2.5. The product precipitates as off-white colored crystals.
This pH Is blue color on Congo Red paper.
The sulfuric acid must not be added too rapidly as the heat evolved during the addition could cause the charge to boil out or splatter due to steam from the heat of dilution of sulfuric a&id. The temperature should not be allowed to deviate from 95 + 2C. The exact isoelectric point has not been"*established, but experience has shown the pH range of 1.5 to 2.5 to be optimum. The time for adding the required 655-675 pounds of acid is 1 1/2 to 2 1/2 hours. The effect of more rapid acid addition with simultaneous cooling of the charge has not been determined.
Operating experience has shown that the acid can be added in forty-five minutes to one hour. The temperature limits of 95 + 2C. and a safe non-splattering condition are maintained during this shorter addition.
RECOMMENDATIONS
It is recommended that this change in the Process be adopted. This will allow us to manufacture the product more efficiently and shorten the cycle time.