American Society of Heating and Ventilating Engineers Guide, 1936
State
Table 1. Average Maximum Water Main Temperatures3
City
Temp. F
State
Crrr
Temp. F
84 Boston.... ...........
Mobile........................ 73
Cambridge........
Ariz______ Phoenix.................. -- 81
Fall River.-......
Tucson.......................
80
Lowell-................
Calif..
60 Lynn...................
Berkeley...................... 69
New Bedford.....
Fresno......................... 72
Salem.................
Fullerton........ ;........... 75
Worcester..........
Glendale..................... 68
Mich... ....... Detroit............... .
Los Angeles............... 75
Flint.....................
Oakland.........:............ 69
Grand Rapids...
Ontario........................ 70
Highland Park..
Pasadena..... ............. 82,
Kalamazoo.........
Pomona....................... 75
Lansing.... ..........
Riverside.................... 78
Jackson.... ..........
Sacramento................ 72
Saginaw..............
San Bernardino..... . 65
Minn-....... Duluth............ ....
San Diego.... !............. 82 `
Minneapolis.......
San Francisco.:......... 62
St. Paul.:.... ........
75 Jefferson City...
75 Kansas City.....
66 St. Joseph:... ......
Hartford-................. 73 '
St. Louis:__ J......
New Haven............... 76
Springfield........
72 Lincoln........ ......;
D. C........... Washington..............- 84
Omaha................ 1
83 Reno.............
Fla.............. Jacksonville.:............ 80
n. h:
Manchester.......
80 N. J.
Jersey City.........
Tampa...............
7T -
Newark.--.:......... .
Ga.........IC; Atlanta..................... . . 87 :
Paterson..........:...
Macon.................. :..... 80
Trenton____
111. ...... Chicago...................
76 N. Y._........ Albany................
Cicero.......................... 76
Buffalo................
Evanston.................... 73
Jamaica.... ..........
Peoria.......................... 67
Mt. Vernon...__
Rockford...:.......:....^ 59
New Rochelle:_
Springfield....:........... 82'
New York......
Ind....... . Evansville..--.........:... 86 .
Rochester...........
Gary..:
.75-
Schenectady.......
!r
Indianapolis.'.....:...:... : 80 . . ,
" .. , Syracuse...:.........
South Berid;--._.....
61
Utica....:,.............
Terre Haute............:. . 82
Yonkers....... .......
IoW3^_:.j:__ Cedar Kapids.... .....u - 78. .. . N. C........... Asheville.:.--........
Des Moines...... ......
77.
Charlotte....-^....
Sioux City....:.......
62.
Winston-Salem..
Kans.. .......
57 N. M.
Albuquerque..,..:
Kansas City.......... . 86
Akron...?........... ...
Topeka....... ..............
88
Canton
....
Wichita.^.,,....... 1........ 72' . '
Cincinnati--......
Ky.............,. Louisville.................. . 85 .
La....--;. Baton Rouge...........
85
Cleveland ...--.. Columbus.,..........
New Orleans.........: Me.......-...;:. Augusta..--...........;..
85 ' ' 60
Lakewood__ Springfield.........
Md--...... Baltimore........:...... . 67
Toledo"-.......... ,.
80 70 76 50 68 70 68 76 77 70 84 77 53 . 64 56 82 55 . 80 77 82 84 84 85 70 87
' 87 61 76 ` 63 74 ' 78 79 68 75 56 74 75 72 70 .
: 60 ' 74.
69 70 . 74
85 ' 82
65 76 50 84 "74
82 . 60 82 72-
.83 .
' aThese averages taken from various city water main locations, with some actual values slightly higher
and some lower than values shown. -.
: ; ,, ,
. ; ....
:
180
Chapter 10- -Cooling Methods
R. I-- S. C.....
S. Dak Tenn--.
Texas
1 Average Maximum Water Main Temperature3 (Continued)
CtTI ' '
Temp. F
State
. City'
Temp. F
Oklahoma City~
Tulsa.--------------Eugene'......... -...... Portland................
Altoona........ ,......
Erie. Johnstown............. McKeesport.......... Philadelphia.......... Pittsburgh............. Providence....... -- Charleston............. Greenville.............. Spartanburg.----
Rapid City-......... Chattanooga......... Knoxville....... . Memphis------- ....... Nashville.--......... Amarillo............ ... Austin........:........... Beaumont--........... Dallas..........--...... Fort Worth......... Galveston--...... ...... Houston.........--.... Port Arthur------San Antonio........ Wichita Falls.:----
82 .85, 60 64
. 74 75. 74 82'
83 67 68 80
81 78 55 84
89 70 90 65 90 86 86 84
90 84 83 76
85
44 -
Salt Lake City______ . 60 ' :
Va.............. : Fredericksburg.____
75.
Lynchburg................ . 73
Norfolk........................ 80
58
Seattle. ....... ---___ 62
Spokane...................... 51 -
Tacoma. .................. 57
W. Va_____ Charleston...............
85
Huntington......... ..t.
78
Wheeling-- __-i--___ 78
Wis.
54
, 58' .
Milwaukee...... ..... i--. ' 70
Racine..........j........
-.68.
Phovtnce
Alta.--......... Calgary. .................. B. C............
, Toronto...... ................ P. E. I........
Quebec...--'^........... --
64 60 50 63 48 . 78 68
aThese averages taken from various city water main locations, with some actual values slightly higher and some lower than values shown.
mentioned. Cooling by evaporation is satisfactory only when the air to, be cooled is very dry; air motion as a means of producing cooling effect is never entirely adequate in the range of high, temperatures. Of the two, evaporative cooling, or adiabatic saturation of the air, is a much more, dependable method which will make more reduction in the effective temperature than will an increasing, air motion within permissible limits.
As an example of this, consider, an outdoor condition of 96 F dry-bulb; and 80 F wet-bulb. The effective temperature is. 85.7 F and,, if the,-still;
air is moved,with a velocity of 300fprii,,the effective ,temperature-will be.
reduced only 2.0 F while saturation at the .wet-.bulb temperature would
reduce the effective temperaJure 5.7 F. At300.fpm velocity this satu
rated air would reduce the effective temperature to, 75.6 F, thus making a
total improvement of 10.1 F. ... .
\* .
Frequently the temperature of the city-water main, supply is. lowenough during the summer- to.; permit an appreciable cooling;. effect,:r Table 1 lists the maximum city watef main temperatures for various
localities in this country and Canada.
-
. .
Evaporative Cooling
''
Evaporative- cooling is accomplished by passing. air through a water
181-