Document 93Xxrm9nED5Ogmo9z3VB8qre7
Union Carbide Agricultural Products Company, Inc.
Institute Plant
INDUSTRIAL HYGIENE SAMPLING RESULTS
TO: Mr. D. A. DugaCOPIES TO:
Mr. R. F. Jenkins
Building: 23
Mr. C. E. Miller
Institute Plant
Mr. L. W. Youngblood
Purpose:
Routine
Special Request
Regulatory Agency Inspection
Sample Date(s): November 12, 1986
Sample Location: Vehicle Garage Department No.:
Process/Activity:
Brake cleaning, repair and replacement
327
Contaminant: Asbestos Fibers
Exposure Limit:
OSHA 0.2f/cc(TWA^);-(TWA^)
Sample Type:
ACGIH 0-2f/cc(TWA ) ;~
o
UCC
________________________(TWA ):-(TWA o
X Personal
X Area
________ Source
(TWA )
JL Z.
) 1Z
Surface Wipe
________ Other (See comments)
Analytical Method:
Per 29 CFR 1910.10Q1, Appendix A
Results:
_____ See Comments
X See Attached Table
COMMENTS: Two auto mechanics were monitored for exposure to airborne asbestos fibers on the above date while performing vehicle brake maintenance. Area concentrations of airborne asbestos fibers were measured too. The maintenance activities included cleaning the brake shoes and drums on a van, installing new brake shoes on a forklift and cleaning the drums and brake shoes on a flatbed truck.
In order to minimize asbestos fiber generation, Varsol was applied to the brakes during maintenance. In addition, one of the mechanics wore a respirator while servicing the van and the forklift. The other mechanic used no personal protection while working on the flatbed truck. All of the work was performed inside the garage.
AU399
UCC 008978
Union Carbide Agricultural Products Company, Inc.
Institute Plant I N D U S T RIAL HYGIENE SAMPLING RESULTS
The 8-hour time-weighted average exposures for the two mechanics were well below the permissible exposure limit and the action level (i.e., less than one-half the PEL). In addition, two area samples taken in close proximity to the brake maintenance work areas were below the action level. A third area sample, taken in the vicinity of the new brake pad storage area, was well below the action level.
Currently, no action is required except that these results must be reviewed with all affected employees (i.e., any auto mechanics who may perform brake maintenance). In lieu of reviewing this, a copy of the results may be posted in the garage area where all affected employees can see it.
Please contact this office when additional brake maintenance occurs so
more monitoring can be performed. If you have any questions on this, call me
at the extension shown below.
Report Date: Signed NOTE:
January 12, 1987 Bldg. 2
Room: 172 Phone
PERSONAL SAMPLE RESULTS MUST BE DISCUSSED
WITH ALL AFFECTED EMPLOYEES
6105
2183k
UCC 008979
A U 3 3 9 ij
Union Carbide Agricultural Products Company, Inc.
Institute Plant
INDUSTRIAL HYGIENE SAMPLING RESULTS
WORKPLACE LOCATION: Vehicle Garage
NAME(s) OF SAMPLER(s): J. L. Miller
CONTAMINANT: Asbestos Fibers_____________ OSHA PEL: TWAg Q.2f/cc TWA] > ~
REPORT DATE: January 12, 1987 ACGIH TLV: TWAg Q-2f/cc TWA]9 UCC GUIDELINE: TWAg - TWA12 ~
Sample Number
Sample Date
W4765 AA10429
W4765 AA10433
W4765 AA10431
W4765 AA10432
W4765 AA10430
11-12-86 11-12-86 11-12-86 11-12-86 11-12-86
Sample Description
Sample Time (min.)
Sample Results (f/cc)
AUTO MECHANICS L. M. Hoffman
400
0.006
TWAg = 0.005
W. c. Glenn
Five feet south of Chevy van while brakes were in spected and cleaned.
100
0.01
TWA 8 = 0.002
40 0-05
Front of fork truck while new brake shoes were in stalled .
Breathing zone level next to shelf where new brake pads and shoes are stored in storeroom.
391 165
0.009 0.006
AO 99 7
UCC 008980