Document 93LnQjrmXNGy21vMJE0dvrg0V

Gypsum Plaster A Gypsum Lath A Plaster Wall Systems ^ Plaster Ceiling Systems Dens-Cotes Plaster Veneer Systems i I! SGP 0023002 January, 1971 * * Lath GYPSUM PLASTER G-P/Bestwall laths and plasters, although always consist ently a superior product, have one unique and important additive which makes them very much in demand. This is the addition of uniform length, high strength glass filament fibers. The fiber glass content of G-P/Bestwall fibered plas ters and laths is an important factor to consider in speci fying lath and plaster construction. Fast Machine Application Literally miles of glass fibers (19.75 miles per bag of fibered plas ter) offer greater resilience and bonding properties that resolve many job difficulties. Glass fiber reinforcement provides greater speed in application which in turn results in better economy. G-P/Bestwall plasters, designed for machine application, give greater construction economies and added design possibilities. Glass fibered plaster may be used when fibered plaster is speci fied. Due to the plasticity and richness of these plasters they will not clog the mixer, hose or nozzle. Even the glass fibers go through. DEIUS-COTE Veneer Systems Dens-Cole (one coat) system is designed for use whenever a strong durable finish with maximum speed and minimum material is desired. One application of only yi2" minimum thickness DensCote Smooth Finish (or Textured Finish) over Dens-Cote Gypsum base, is all that is needed to give lasting strength and beauty to any construction. Dens-Cote System (two coat). This system is designed for those who prefer the conventional type finishes but desire modern speed and minimum material. The specially designed Dens-Cote Plaster, stronger than conventional sanded plasters, base shall be applied Va" thick over Dens-Cote Base to achieve the best results. As in the one coat system, the Dens-Cote Base Plaster can also be used over porous masonry block with excellent results. After the first coat of Dens-Cote Base Plaster has set, finish with lime putty and gauging for a conventional smooth finish, or use any sand float textured finish. For a hard durable smooth finish, use Dens-Cote Smooth Finish. 0 Description Neat gypsum plaster (Unfibered. Fibered. and Extra Fibered) Basecoat plasters bond securely to any standard plaster base including gypsum lath, metal lath and masonry units. Neat gypsum plasters require addition of aggregate and water. Lite-mix plaster (Unfibered, Fibered, Masonry Mix) Basecoat plaster that is 50% lighter than Gypsum and sand plaster. Fibered mix contains glass fibers for added strength. Requires addition of water only. Wood fibered gypsum plaster Non-staining shredded wood fiber additive provides good working properties when used without aggregate. Gauging plaster Specially ground gypsums designed to blend with lime putty. Finishing limes Produced from ground Guicklime by adding an exact amount of water which chemically converts the quicklime to calcium and magnesium hydroxides. Completely aerated to prevent lumping m the bag. Uses 1. UNFIBERED: is used for scratch coat on solid surfaces and for the brown (second) coat on any backing. 2. FIBERED: is recommended to provide greater wet cohesion and to minimize droppings with open type lath. 3. EXTRA FIBERED: is used for greater wet cohesion over metal lath as may be specified. 1. UNFIBERED: is used for scratch coat on solid surfaces and for the brown (second coat on any backing.) 2. FIBERED: is recommended to provide greater wet cohesion and to minimize droppings with open type lath. 3. MASONRY MIX: Available for application on masonry bases. Intended for use without aggregate as scratch and brown coat, but may be mixed with one part of sand. For scratch coat over high suction masonry it is recommended that one part of sand be used. Mixed with lime to provide base for final wall and ceiling decoration. Usually over a gypsum plaster basecoat. Vie" to Va" thick. Available in "Slow Set" or "Quick Set." Precision ground to produce the correct fineness for maximum plasticity and workability. To be mixed with gypsum gauging or Keene's cement for lime putty white coat. Features DURABILITY: Applied according to specifications it provides uniformly strong, stable walls and ceilings. PLASTICITY: Special scientifically controlled process maintains plasticity and easy workability. FIRE RESISTANT: Gypsum's natural incombustibility offers superior fire protection. FIRE RESISTANT: Perlite aggregate provides higher fire resistance than sanded plasters. MIXES SMOOTHLY: Has no tendency to clog mixer or to block the nozzle of the plaster gun. HIGH INSULATION VALUE: Provides greater insulation than sanded gypsum plaster. - ECONOMY: Can be applied quickly and easily. STRENGTH: Has 3 times greater compressive and tensile strength than sanded plaster: up to 2% times greater resistance to lateral impact and 50% greater surface hardness. WHITE COAT FINISH: Satin Spar Gauging Plasters are very white and when properly mixed with lime putty they provide glossy smooth, flawless, surface of uniformly excellent, satin-llke finish. Supplies a white durable finish that preserves and beautifies interior walls and ceiling. Makes walls less brittle, less subject to cracks. Prepared trowel finish A pre-mixed gypsum finish coat plaster requiring addition of water only. Made from high grade gypsum rock of white or local gray. Keene's cement A high strength, "dead-burnt" white gypsum gauging plaster. Provides stronger, harder surface wnen substituted for gauging plaster iinn aa lniminee mi(iiixa.. Llpesjsj lniminee,. hI'aairvdver finish. Available regular and fast Set. For any indoor plastering installation where a smooth hard finish is desired. Because of denser, harder surface has higher resistance to abrasion and water absorption it is highly suitable for kitchens. bathrooms, hospitals, and any area where wear and moisture resistance are important. STRENGTH: Produces very hard surfaces, approximately twice the strength of ordinary lime-gauging finishes. EASY DECORATION: Can be decorated as soon as dry. LOW WATER ABSORPTION: Because of high density, has low absorption. VARIOUS FINISHES: Mixed with varying portion of lime, gives standard, medium hard or extra hard finishes. SGP 0023003 E/2 Far '3ted fire res-stive instruction use G-P Bestiall gypsum products with G-P Paneling. See "Georgia-Pacific Guide to Products for Interior Pane mg, 9.5/Ge QUICK SELECTOR CHART For G-P/Bestwall Plaster Products LIME PRODUCTS G-P/Bestwall Smooth Finish Lime NAME USES COVERAGE THICKNESS (sq. yds per ton) NEAT Unfibered Fibered Extra Fibered UTE-MIX Unfibered. Fibered Masonry Mix WOOD FIBERED Scratch coat on solid sur* faces. Brown coat on any surface. Scratch and brown coat on all surfaces except monolithic concrete. Scratch coat on metal lath but may be used over all bases except monolithic concrete1. (sanded 2:1) Gypsum Lath: 190*220 Metal Lath: 100*130 Gypsum Tile: 210*240 Clay Tile: 165*200 (same as above) VtV,' H' (same as above) (same as above) (same as above) Where lightweight desired. Ready mixed, add water only. Faster, easier application. For use over high suction masonry base. Gypsum Lath: 135-150 Metal Lath: 75-90 Gypsum Tile: 135-150 Clay Tile: 110-125 'h' v vr %" Without sand-scratch coat and brown coat on ail backings except masonry. With sand-scraicn coal on masonry and brown coat on ail backings. (without sand) Gypsum Lath: 100*120 Metal Lath: 50*65 Gypsum Tile: 85*100 Ciay Tile: 65*85 w* H' Vt- SATIN SPAR GAUGING (White) G-P/BESTWALL GAUGING PREPARED TROWEL FINISH PREPARED SAN0 FLOAT FINISH KEENE'S CEMENT MOLDING OENS-COTE SMOOTH FINISH OENS-COTE TEXTURE FINISH OENS-COTE BASE PLASTER FINISHING LIME SMOOTH FINISHING (Normal Hydrated) BUILDERS (Autoclaved) Mixed with hme for use over gypsum basecoat. Great workability, nard, smooth white surface. Available m quick set or slow set. 1600 ft* (3:1) Mixed 3 parts lime putty to 1 part gauging (Mm.) Mixed with lime (or use over gypsum basecoat. Selected Quality rock, light gray color. Gives hard, smooth surface. Available <n quick or slow set. 1600 'V (3:1) Mixed 3 parts lime putty to 1 part gauging (Mm ) Where uniformity and extra hardness are desired. Can oe decorated when dryno waiting period. For use over gypsum basecoat only. White or gray color. Mixed with water only. 350-400 Same as prepared trowel finish except surface will be textured. White or gray color. 250-235 Mixed with lime Gives strong, dense surface with resistance to abrasion and water Two sets regular and fast finish. (4:1 Mix) 550 vtade Irom rock over 9854 cure Gives hard, strong -noids and coats with low expansion. Mixed with lime and water lor ornamental `eatures. M xed w.th water only. For :hm coat application to Dens-Cole Gypsum Base. Up to 400 W Minimum Same application as Smooth Fimsn. Milt mixed texture material, texture with float as desired. Up to 400 ViT Minimum First coat in two coat veneer piaster system. Finish may be Smooth Finish or Lime Putty mixed with gauging. Up to 400 W Minimum Oens-Cote Smooth or Textured finish may be applied to masonry Bloch m two coat application. Base coat minimum thickness ot Vi* or enough to straighten wall. Finish coat may be smooth or textured as desired. (Ohio Dolomite) M.xed with gauging, molding plaster or Keene's Cement to give plasticity, whiteness and bulk. Up to 750 Vtm A normal hydrated lime that must be soaked approximately 16 hours and then blended in proper proportions (one gal lon of gauging plaster to every three gallons of lime putty) with gypsum gauging plaster which provides initial set and strength avoiding shrinking cracks. G-P/Bestwall Builders Lime This finishing lime is made from the same quicklime as G-P/Bestwall Smooth Finishing Lime, but is hydrated in a steel Autoclave (pressure vessel). Water is injected and after the quicklime satisfies its chemical thirst for water, the lime is removed from the Autoclave chamber as dry hydrate and undergoes aeration to remove any possible uncombined moisture. This lime has less than 8% of unhydrated oxides and pre vents "lime pops." Builders Lime need only be mixed with water to a putty consistency and can be used without soak ing. G-P/Bestwall Builders Lime has more workability and plasticity than other finishing lime. G-P/Bestwall Mason's Lime This is normal hydrated lime made from quicklime and-- except for its coarser quality and shorter aeration process --the manufacture, hydration and milling are approximate ly the same as tor G-P/Bestwall Finishing Limes. G-P/Best wall Mason's Lime should be soaked at least 12 hours in putty form before use in mortar ... it should not be used as finishing plaster because the finish will not be up to standard and "pops'' may occur. G-P/Bestwall Speedy Mason's Lime This is the original Type "S'1 Special hydrated lime, a quick mix lime that need not be soaked in putty form before use. Produced by a continuous pressure on Autoclave system. G-P/Bestwall Speedy Mason's Lime differs from Bestwall Autoclaved Finishing Lime only in the coarser quality of the quicki.,ne used. Efflorescence .s minimized because the lime is free of soluble salts. SGP 0023004 Beam fireproofing Fireproofing of beams and col umns is accomplished by abut ting 3/a "G-P/Bestwall Perfoiath around the perimeter of the beam or column and plastering the thickness required for de sired fire resistance rating. The Perfoiath is held by tying double strands of the wire around the iath and spaced 16" o.c. corner heads applied by staples or tie wire provide ground for proper thickness as well as straight true corners. Sanded plaster is used for fire ratings up to three hours. Light weight aggregates provide fire ratings up to four hours. A four hour column rating requires two layers of Vi" thick gypsum lath. georqia-pacific/bestwall E/3 GYPSUM LATH Type and Size Plain lath, type X Consists of core of gypsum rock reinforced with glass fibers sandwiched between two layers of special paper covering. This is standard basic construction for all Bestwall Lath. SIZE: 16"x48", 16"x96", Va' or Vi" thick (16V,"x48" West Coast only) Long-length lath type X The same structure as Plain Lath except in dimensions SIZE: Available in or 1" thicknesses--24" x floor to ceiling lengths (121 maximum). Uses The standard gypsum plaster base for nail, staple or clip application to wood or steel framing. This construction material is especially designed for use as a plaster base for thin (2") solid partitions providing fire resistive ratings up to two hours. Can also be used with furring over exterior masonry walls as a plaster base. Description The exposed layer is porous and absorbent, permitting water in the plaster to penetrate the surface. As plaster sets, gypsum crystals pierce the paper surface forming mechanical key on the lath thus assuring maximum bond. Glass fiber reinforcement gives the lath added strength and fire resistance. All G-P/Bestwall Gypsum Lath, having glass fiber, is Type X Printed face so identifies lath. Lath paper has water resistant inner plies which prevent the water in the plaster from soaking through it and thus minimizes sagging of the lath and plaster. The layer against the core is porous and absorbent so as to bond the core as the plaster sets. Long Length Lath comes in lengths up to 12', providing for wail assemblies in floor to ceiling heights, ideal for solid plaster par titions. Since there is less lathing in job--there is a saving in construction costs. Glass fiber reinforced for added strength Fast and economical to erect. Application: Both piain and Long-Length Lath may be applied by nailing to wood and nailing-type steel framing, and to wood fram ing by staples. They can be easily attached to metal sections and furring, and to wood with lath clips. Resilient type clips reduce cracking and lessen sound transmission. Pinholath, type X Plain Lath construction surface perforated with Vi,' dia. holes. Space H' o.c. diagonally. SIZE: 16"x48", 16"x96", %" or >/2" thick (16'/i"x48" West Coast only) Specially designed for machine applied plasters. Fast, high, even water absorption speeds plaster application by holding plaster in place during rodding and darbying. When attached to ceilings by clips, three coat work is required. The Scratch Coat should be dry before applying Brown Coat if high humidity condition exists. When Perimeter Clips are used on ceilings. Butt and Center Clips should be used. G-P/Bestwall PINHOLATH is plain lath surface-perforated in manufacturing with pin holes no larger than Vis" in diameter, spaced 36 " o.c. diagonally. Specially designed for machine applied piasters. Its unique feature permits rapid suction of water from plaster mix to achieve perfect plaster consistency speeding plaster application. There is no plaster slide, no backtracking, no costly delays. Plaster stays in place during rodding and darbying which can be done sooner when using PINHOLATH. Full base coat coverage is obtainable In one operation. Perfolath Plain lath construction with diameter holes spaced 4' o.c., 48 holes per sheet. SIZE: 16" x 48". V," thick. Applications identical to Plain Lath. A wood stud partition faced with Perfolath and full thickness ot plaster specified has one-hour fire rating. Perforations require application of full thickness of plaster and require separate scratch and brown coats. G-P/Bestwall Perfolath is plain lath with %" diameter holes spaced 4" center to center. The perforations permit the plaster to push through the holes and "mushroom" out the back of the lath, thereby forming a mechanical key. This key plus the natural bond to the face paper, provides a double bond for plaster. Application: Perfolath may be applied by nailing to wood and nailing-type steel framing, and to wood framing by staples. It can be easily attached to metal sections and furring, and to wood with lath clips. Resilient type clips reduce cracking and lessen sound transmission. Insulating lath, type X Plain lath with aluminum foil laminated on back. SIZE: 16" x 48", Vi" or '-y thick. Rounded Edges Designed primarily for application to exterior walls and top floor ceiling. Back side must face a minimum air space of Vi' to develop reflective insulation value. Dens-cote gypsum base A 4' wide, long length, tapered edged, plain lath construction it has a highly acsorbent latn type face paper wth surface pm holed. SIZE: 4' x 8', 10' and 12'. V?" thick (>/," and V,\ W and V Type X Firestop on order) Specially designed for reception of Dens-Cote Smooth and Texture Finish and other thin coat plasters. Conducted exactly as PLAIN LATH this lath has aluminum foil laminated to the back. This foil reflects up to 90% of radiant heat and acts as an efficient vapor barrier. Designed primarily for application to exterior walls and top floor ceilings. When installed the aluminum reflective surface must face a minimum air space of Vi " to develop reflective insulation value. sgp 0023nr)5 G-P/Bestwall Dens-Cote Gypsum Base is a Vt" and Vs" thick, 4' wide, tapered edge, gypsum board product, specifically designed to receive Dens-Cote Plasters. It has a highly absorbent lath type face paper with the surface pinholed. Available in lengths up to 12', is shipped twin mounted. Large sheets decrease number of joints, giving greater strength and crack resistance to wall and ceiling surfaces. The Dens-Cote System is designed for fast erection and early occupancy; produces a wall with a strong, hard monolithic finish. Combines economy of installation with virtually unlimited deco rative possibilities. E/4 for rated fire resistive construction use G-P Bestwall gypsum products wit* G-P Paneling. See ``Georgia-Pacific Guide to Products for Interior Paneling." PLASTER WALL SYSTEMS 9.5/Ge Technical data-Fire ratings & sound transmission values for gypsum lath & plaster wall systems PLASTER CONSTRUCTION TYPE BASE MIX 1 part of Gypsum Plaster (100 pounds) to cu. ft. aggregate THICKNESS Face of Lath to Face of Finished Surface PARTITIONS Description Thickness (2 Mixes--Scratch and Brown) (1 Mix--Scratch Double-Up) 2* x 4" Wood Studs 16" on Center 5V' 514* 53/8" 514" 5y," 53/s" 514" 514" 5V,' 514" 43/" 6" 3/b" Bestwall Plain Gypsum Lath V," Bestwall Plain Gypsum Lath 3/b" Plain Gypsum Lath 14" Plain Gypsum Lath 54" Perforated Gypsum V," Perforated Gypsum Metal Lath 3.4 D.M. Metal Lath 3.4 D.M. Metal Lath 3.4 D.M. Metal Lath 3.4 D.M. One layer 14" Bestwall Firestop Dens-Cote base, both sides. Two layers V," Bestwall Firestop Dens-Cote base, both sides. Gypsum-Sand 1:2 Gypsum-Perlite 1:2 Gypsum-Sand 1:2, 1:2 Gypsum-Wood Fiber Gypsum-Sand 1:2, 1:2 Gypsum-Perlite 1:2, 1:2 Gypsum-Sand 1:2, 1:3 Gypsum-Wood Fiber Gypsum-Perlite 1:2, 1:2 Gypsum-Vermiculite 1:2, 1:2 Dens-Cote smooth finish Dens-Cote smooth finish 14" 14" 14* 14" 14" 14' Vi' Vi' Vi' Vi' Viz' Viz' FIRE RATING WEIGHT LBS. PER STC SQ. FT. 1 Hour 1 Hour 45 Minutes 1 Hour 1 Hour V/z Hours 1 Hour 2 Hours 1 Hour 1 Hour 1 Hour 15 12 14.7 _ _ _ _ _ _ 7.7 2 Hours 13.8 4_0 40 _ _ 40 41 40 40 35 41 Solid Partitions 2* 2* 2' 2' V/z' 2Vz' 14" Long Length Gypsum Lath Vz" Long Length Gypsum Lath 14* Long Length Gypsum Lath Metal Lath Metal Lath Metal Lath Gypsum-Sand 1:1, 1:2 Vi" Gypsum-Perlite 1:2 3A' Gypsum-Perlite or Vermiculite 1:2,1:2 Vi' Gypsum-Sand 1.2, 1:2 1" Gypsum-Perlite 1:2 V Gypsum-Perlite or Vermiculite 1:2,1:2 114" 1 Hour 114 Hours 2 Hours 1 Hour 1 Hour 2 Hours 16.5 10.9 18.1 7.4 34 37 36 33 34 Steel Frame 5V,' 514" 5V,' 5V,' 53/8* 514" 514" 3V 3l/is" 4"/l6* 6Vl6* 3/8" Bestwall Pinholath, 35/8" Stud 3/8" Bestwall Pinholath, 354" Stud 3/s" Plain Gypsum Lath, 35/8" Stud 3/8" Bestwall Pinholath, 35/8" Stud V," Perforated Gypsum Lath, 354" Stud Metal Lath, 354" Stud 3/b" Bestwall Gypsum Lath-Type "X" attach with clips each side of 214" steel stud. 34" Perforated Gypsum Lath, 15/b" Stud One layer 5/8" Bestwall Firestop Dens-Cote base, both sides, ls/8" metal stud. Two layers 14" Bestwall Firestop Dens-Cote Base. Both sides-- 214" metal stud. Two Layers 54" Bestwall Firestop Dens-Cote Gypsum Base, Both Sides--3%" metal stud Gypsum-Sand 1:2 Gypsum-Perlite 1:2 Gypsum-Perlite 1:2 Gypsum-Sand 1:2 Gypsum-Sand 1:2, 1:2 Gypsum-Sand 1:2, 1:3 Gypsum-Sand 1:2 Gypsum-Perlite 1:2, 1:2 Dens-Cote smooth finish Dens-Cote smooth finish Dens-Cote smooth finish COLUMNS Columns (Steel) 3/b" Pefrorated Gypsum Lath 3/8" Perforated Gypsum Lath 14" Perforated Gypsum Lath 14' Perforated Gypsum Lath 2 Layers 14" Plain Gypsum Lath Metal Lath Metal Lath Gypsum-Sand 1:214 Gypsum-Sand 1:2, 1:3 Gypsum-Perlite 1:2!4 Gypsum-Perlite 1:2, 1:3 Gypsum-Perlite 1:2, 1:3 Gypsum-Sand 1:2, 1:3 Gypsum-Perlite 1:2, 1:3 14" 14" 14" 14" 14" Vi' 14" 34* 142* 142* Viz ' 1 Hour 1 Hour 1 Hour 1 Hour 1 Hour 1 Hour 1 Hour 2 Hours 1 Hour 2 Hours 2 Hours 14 10 16 16 to 21 16 to 21 21 11.8 44 -- 35 -- 35 41 45 15 -- 7.0 38-40 9.8 48-50 12.8 49 14" l3/8" 1" 114' 114" 54" 114 " 1 Hour 2 Hours 2 Hours 3 Hours 4 Hour 1 Hour 4 Hours -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGP 0023006 geopgia-pacific/bestwall E/5 A PLASTER CEILING SYSTEMS Technical data--Fire ratings & sound transmission values for gypsum lath & plaster ceiling & floor assemblies. PLASTER CONSTRUCTION TYPE BASE MIX 1 part of Gypsum Plaster (100 pounds)to cu. It. aggregate THICKNESS Face of Lath to Face of Finished Surface FIRE RATING WEIGHT 9 LBS. PER FREQUENCY SQ. FT. AVERAGE (1) Wood Joists and Floor Assembly No. t Assembly No. 2 Assembly No. 3 V4' Bestwall Pinholath *H' Bestwall Pinholath *H* Bestwall Type X Gypsum Lath Vi' Perforated Gypsum Lath *H' Perforated Gypsum Leth Vi' Perforated Gypsum Leth Metal Lath Metal Lath V4 ' Bestwall Fitestop Dens-Cote Base, one layer nailed. Vi' Bestwall Firestop Dens-Cote Base, one layer an resilient Channel H' Bestwall Firestop Dens-Cote Base, two layers with resilient channel, 24' o.c. between layers Gypsum-Perlite 1:2 Gypsum-Sand 1:2 Gypsum-Sand 1:2 Gypsum-Sand 1:2 Gypsum-Sand 1:2 Gypsum-Perlite 1:2 Gypsum-Sand 1:2, 1:3 Gypsum-Perlite 1:2, 1:2 Oens-Cote Smooth or Textured Finish Dens-Cote Smooth or Textured Finish Oens-Cote Smooth or Textured Finish Vi' 1 Hour ___ ___ Yt' 1 Hour -- -- 14' 1 Hour -- Yt' 45 Minutes 12.5 -- 40 Vi' 1 Hour -- -- Vi' 1 Hour -- -- H' 1 Hour 17.5 32 to 34 Vi' lVi Hours -- -- Via' 1 Hour 13.9 -- 'At' 1 Hour 13.9 44 'At' 2 Hours 16.9 -- Steel Joists (2* Floor Slab) Furring Channels 16' o.c. 16' o.c. 16' o.c. 16' o.c. 12' o.c. 16' o.c. 12' o.c. H' Perforated Gypsum Lath (Clips) H' Perforated Gypsum Lath (Clips) Vi' Perforated Gypsum Lath (Clips) Yt' Perforated Gypsum Lath (Clips) Vi' Perforated Gypsum Lath (Clips) Yt" Perforated Gypsum Lath Plus 1' Mesh Vi' Perforated Gypsum Lath (Clips) Plus 1' Mesh Metal Lath Metal Lath Metal Lath Gypsum Perlite 1:2 Gypsum Vermieulite 1:2 Gypsum Perlite 1:2, 1:2 Gypsum Perlite 1:2 Gypsum Perlite 1:2, 1:2 Gypsum Perlite 1:2 Gypsum Perlite 1:2, 1:3 Gypsum Sand 1:2, 1:3 Gypsum Perlite 1:2, 1:2 Gypsum Vermieulite 1:2, 1:2 K' H' 1' Vi' u/i.' At" 1' Vi' 'Mi' 1' 1 Hour 1 Hour lVi Hours -- 3 Hours 3 Hours 4 Hours 2 Hours 3 Hours 4 Hours -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- - Steel Floors 2 to ZVt' Concrete Floor with Suspended Ceilings 12' o.c. H' Perforated Gypsum Lath Plus Clips and Wiie Reinforcing Metal Lath Metal Lath ^Assembly No. 1 2V4' Concrete floor Vi* 8estwall Firestop Dens-Cote Base, over Metal Lath one layer screwed metal furring over Steel Bar 24' o.c. Joists 24' o.c. Gypsum Perlite 1:2 Gypsum Perlite 1:2, l:3t Gypsum Wood Fiber Dens-Cote Smooth Finish Vi' on Ceilings 3 Hours VA" on Beam) 1' 4 Hours Vi' 4 Houis 'At' 2 Hours ---- ---- --- 39.4 -- f Assembly No. 2 2' Concrete Floor on joists 24* o.c. Vi* Bestwall Firestop Oens-Cote Base, one layer screwed metal furring 24' o.c. Dens-Cote Smooth Finish At' 2 Hours 37.3 SGP 0023007 NOTE: All tables are summaries only, based on tests at Underwriters' Labora tories. National Bureau of Standards. University of California. Ohio State University, Geiger and Hamme. Riverbank Laboratories and/or Ohio Research corporation sponsored by the G-P Gypsum Division, Gypsum Association, Metal Lath Association. Perlite Institute, Vermiculite Institute or others. The fire rating, weight and sound characteristics are based on a combination of specific details as tested and published. More complete Listings and Details are available. INCONSISTENCIES IN TEST RESULTS ARE DUE TO TESTS OVER A PERIOD OF MANY YEARS AND VARIATIONS IN LABORATORY FACILITIES. All of the test results have been obtained under laboratory testing conditions where controlled environment reduces variables to a minimum. In the field, such laboratory conditions are not always met, since many other variables are introduced. Laboratory results may exceed results of field tests, but the labora tory tests under controlled conditions are the only logical way to compare the performance of different assemblies. The Gypsum Division of the G-P Corpora tion makes no warranty that the performance of assemblies in the held wui have a performance equal to or better than that developed in the test. NOTE: Floor and Ceiling assemblies (Incombustible), Bestwall Firestop Dens Cote Base, may be direct attached or suspended. For rated fire resistive construction use G-P/Bestwall gypsum products with G-P Paneling. See "Georgia-Pacific Guide to Products for Interior Paneling." DENS-COTE PLASTER VENEER SYSTEMS 9.5/Ge DENS-COTE* base WOOD FRAMING 1. Horizontal Application--Apply Dens-Cote base hori zontally to framing so that ends fall on framing members. Nail with GWB-54 nails or equal, meeting ASTM C-514 having approximately 1 i ' heads. Length of nail shall be that which will provide at least 3 4 ' penetration into studs. Space nails on both edge and intermediate supports 7" o.c. (maxi mum) on ceilings and 8" o.c. (maximum) on sidewalls keep ing %" from edges of base. Stagger end joints on opposite sides of partition. METAL FRAMING 1. Horizontal Application--Set G-P/Bestwall 25 gauge metal studs spaced 24" o.c. into G-P/Bestwall floor and ceiling track. Apply Dens-Cote Base (Vz" or 5/a") using 1" self-tapping sheet metal screws and a power driven screw driver. Space screws vertically 12' o.c. (max.) on edge keeping As" (min.) from the edge. Stagger end joints on opposite sides of partition. DENS-COTE" OVER MONOLITHIC CONCRETE To insure an adequate bond, a bonding agent conforming to ASTM C-631-68T should be applied in accordance with manufacturers' specifications, prior to the application of Dens-Cote Plaster. DENS-COTE" OVER MASONRY BLOCK Apply in two coats. Trowel first coat on sufficiently to straighten wall, but do not trowel smooth. After first coat sets, trowel on second coat. DENS-COTE^ one coat system Georgia-Pacific/Bestwall's Dens-Cote one coat System fulfills its reputation as a system that provides quality walls for either residential or commercial constructions. The Dens-Cote one coat System is used whenever a strong durable finish with maximum speed and minimum material is desired. One application of only minimum Dens-Cote Smooth Finish (or Textured Finish) over Dens-Cote gyp sum base is all that is needed to give lasting strength and beauty to any construction. Although Dens-Cote Smooth Finish (or Textured Finish) is designed to be used over Dens-Cote Gypsum Base, it works equally as well over porous masonry block. APPLICATION--Add one bag (80 lb.) of Dens-Cote Smooth Finish' to 3V2 gal. of water with the mixer turning. Bring the mix to the desired consistency with additional water. A good working consistency will require approximately 4 gal. of water per bag (80 lb.). Mix until the material is lump free. Do not overmix. Dens-Cote Smooth Finish* normally has VA to IV2 hour setting time, so do not mix more than can be applied and finished in that length of time. Use 2V2" wide glass fiber mesh to reinforce all flat joints and angles or conventional paper wallboard tape. Use 1 x 1" minimum-perforated metal corner beads. Corner beads should be set to regulate plaster thickness at Vb " maximum. The mesh must be embedded with Dens-Cote Smooth Fin ish* before the over-all application begins. If wallboard tape is used, use G-P Ready Mix Joint Compound or G-P Speed-Set Compound. At the same time, fill all metal corner beads. These areas may be allowed to set before the overall application is commenced. Trowel the first coat tightly over the entire wall or ceiling surface. This applica tion should be uniform about 115 thick. As soon as the first coat has taken up (5-10 minutes), double back with a leveling coat. :he total thickness ap plied should be H2 thick minimum. The final troweling must be completed before the set takes place. Maintain a temperature of at least 555 F. in the working area 24 hours before, during and after application. In hot weather reduce drafts and ventilation. Plan the work so that it proceeds in an orderly fashion from one end of the surface to the other. This will promote a progressively uniform takeup. DEIMS-COTE two coat system G-P/Bestwall's Dens-Cote two coat System is for those who prefer the conventional finishes but desire modern speed and minimum material. APPLICATION--Mixing and taping instructions are the same as outlined for the one coat system. Trowel a layer of Dens-Cote Base Plaster over the joint area. Trowel the Dens-Cote Base Plaster tightly over the entire wall or ceiling surface. This application should be uniform --about Vb " thick. As soon as Dens-Cote Base Plaster has taken up sufficient ly, straighten wall but do not trowel smooth. Leave rough so that finish coat will key properly. Apply finish coat as soon as possible after base coat has set. Finish with lime putty and gauging for a conventional smooth finish, or use any sand float textured finish. If a hard durable smooth finish is desired use Dens-Cote Smooth Finish. 'Finish coat may be smooth or textured as desired. FOR BEST RESULTS 1. Maintain a temperature of at least 55' F. 24 hrs. before, during and after application. 2. In hot weather reduce drafts and ventilation by cover ng door and window openings. DENS-COTE* SYSTEM PRECAUTIONS 1. Use only clean potable water with Dens-Cote Plasters. 2. Keep mixing equipment and tools clean at all times. 3. Do not mix retarders, accelerators, or any other no-edient with Dens-Cote Base Plasters. 4. Keep Dens-Cote Plaster from freezing until it *s set and dry. 5. Use ONLY G-P/Bestwall Dens-Cote Base with the Dens-Cote System. 6. Do not attempt to retemper Dens-Cote Base Plaste-s. Plan the work so that it proceeds in an oraehy 'asfrom one end of the surface to the other. This wll a progressively uniform takeup. DENS-COTEs radiant heat plaster DENS-COTE BASE 1. Horizontal Application--Apply Vz" Dens-Ccte case at right angles to framing so that ends fall on fram re ~ bers. Nail with GWB-54 nails or equal, meetra -: "V C-514 having approximately `.4 ' heads. Lena:'' - should be that which will provide at least 3a :: into studs. Space nails on both edge and intermea r. ports 7" o.c. (maximum) on ceilings. May also ce arc a over resilient channels. NOTE: Firestop Dens-Cote Base shall be ac:'.;.i . -a-e fire ratings are needed. APPLICATION OF JOINT REINFORCEMENT Use 2V2" wide glass fiber mesh or convert:-wallboard tape and G-P Speed-Set Compcima Mix Joint Compound to reinforce all flat joints The mesh may be stapled to the Dens-Cote .assures positive keying of the Dens-Cote 3a: P'aster to the mesh. = geopgia-pacific/bestwall :I 7 SGP 0 0 2 3 0 0 8 J Install cables and thermostats and make proper connec tions after joints are taped. Cables must be stapled tautly at a minimum of 2" apart. Use cables rated at 2.75 watts per lineal foot at 240 volts. FOR BEST RESULTS 1. Maintain a temperature of at least 55= F. in the working area 24 hrs. before, during and after application of DensCote plaster. 2. In hot dry weather, reduce drafts and ventilation by cov ering door and window openings. 3. Plan the work so that it proceeds in an orderly fashion from one end of the surface to the other. This will promote a progressively uniform takeup. CAUTION 1. Use only clean drinkable water. 2. Keep mixing equipment and tools clean at all times. 3. Do not mix retarders, accelerators, or any other ingre dients with Dens-Cote Radiant Heat Plaster. 4. Keep Dens-Cote Plaster from freezing until it is set and dry. 5. Use ONLY G-P/Bestwall Dens-Cote" Base for DensCote Radiant Heat Plaster Application. 6. Do not attempt to retemper Dens-Cote. STORE IN A DRY PLACE APPLICATION OVER RADIANT HEATING CABLE 1. Trowel the first coat tightly over the ceiling using just enough Dens-Cote to fill in to the thickness of the Radiant Heat Cables. 2. After first coat has thoroughly set apply a leveling coat to cover the cables by at least Va". (Total thickness ap proximately 'A '). 3. When the surface has become firm it may be troweled smooth or floated and textured as desired. 4. The Radiant Heated Ceiling may be painted after it is completely dry. CAUTION: Do not use the Radiant Heat system to dry the plaster or decoration used on the ceiling. When using the system for the first time, turn thermostat to room temperature and raise tem perature 5 degrees each day until desired max imum operating temperature is reached. Specifications 1. Use G-P/Bestwall Dens-Cote Gypsum Base Vz" or 5/a" thick by 4" wide with tapered edges and 8', 10' or 12' long. Apply Vi" Dens-Cote Gypsum Base with ring shank nails 8" o.c. for side walls and 7" o.c. for ceilings, to framing members spaced a maximum of 24" o.c. For fire resistive ratings and other special installations Vz" and 5/a" Firestop Dens-Cote base is available. For these installations use a fastener, with a 3i ' to va" penetration in wood framing members or fastener required for rating. 2. Use 2Vz" wide glass fiber mesh or paper wallboard tape to reinforce all flat joints and angles. Use 1" x 1" perforated metal beads for corners. For best results apply the mesh by embedding it with Dens-Cote Smooth Finish. This is ac complished by troweling a layer of Dens-Cote Smooth Fin ish over the joint area and pressing the glass fiber mesh into the Dens-Cote with a trowel. The mesh may be first stapled to the Dens-Cote Gypsum Base, if desired. In any case, the mesh must be embedded with Dens-Cote before the over-all application begins. Use G-P Triple Duty of Speed-Set Compound to embed paper tape. At the same time, fill all metal corner beads. These areas may be al lowed to set before the over-all application is commenced. Corner beads designed for thin coat applications (not reg ular wallboard corner bead) should be set to regulate plas ter thickness at 3A2" minimum. Nail or screw corner bead to framing member. 3. Trowel the first coat tightly over the entire wall or ceil ing surface. This application should be uniform and about tie" thick. 4. As soon as the first coat has taken up (5-10 mins.), dou ble back with a leveling coat, which will bring the total thickness applied to a minimum of %z". 5. fAfter the second coat has taken up (15-20 mins.), begin final troweling, use water if required. The final troweling must be completed before the set takes place, as evi denced by darkening of the surface. 6. Make joinings at angles. Ceilings should be done first, then sidewalls. 7. Coverage of Dens-Cote Smooth Finish is 14-16 square yards (Viz" thick) per 80 lb. bag. Base Plaster 1. Trowel the Dens-Cote Base Plaster tightly over the en tire wall or ceiling surface. This application should be uni form--about Va ' thick. 2. As soon as Dens-Cote Base Plaster has taken up suffi ciently, straighten wall but do not trowel smooth. Leave rough so that finish coat will key properly. 3. Apply finish coat as soon as possible after base coat has set. 4. Finish with lime putty and gauging for a conventional smooth finish, or use any sand float textured finish. 5. If a hard durable smooth finish is desired use Dens-Cote Smooth Finish. FOR BEST RESULTS 1. Maintain a temperature of at least 55 F. in the working area 24 hours before, during and after application. 2. In hot weather reduce drafts and ventilation by covering door and window openings. 3. Plan the work so that it proceeds in an orderly fashion from one end of the surface to the other. This will promote a progressively uniform takeup. spec.at'y formulated product, designated Dens-Cote Texture finish, is reccmmendea where swirl. sand finish, or other textured surfaces are desired. The same application procedure described for the smooth finishes should be followed with the exception of the final coat. Fcr the texture application, the take up on the final coat will be somewhat dependent on the t<pe ol texture desired. In general, the liner the texture desired, the longer the take up time. In np c3se should the Dens-Cote be tex'ured after it has commenced to set. Texturing may be accompiisned with a float, brush, sponge or other suitable fools. GYPSUM SALES OFFICES ATLANTA P.0. Box 13505, Station K Atlanta. Georgia 30324 SAN JOSE 660 East Gish Road San lose, California 95112 CHICAGO P.0. Box 309 10450 Waveland Ave. Franklin Park, Illinois 60131 SEATTLE P.0. Box 286 12815 NE 178th St. Woodinville, Wash. 98072 DALLAS 1800 John Connally Drive Carrollton, Texas 75006 WASHINGTON, D.C. 8121 Ardmore-Ardwick Road Landover, Maryland 20785 DETROIT 126 E Hudson St. Royal Oak, Michigan 48058 LOS ANGELES 14750 Nelson Ave. City of Industry, California 91744 WILMINGTON Wilmington Marine Terminal P.0. Box 310 Wilmington, Delaware 19899 Lithographed in U.S.A. on G-P Kalamazoo 70 lb. Coronet enamel SGP 0023009 GEORGIA-PACIFIC / E/8 for rated fire 'esistive construct,on jse G-P Bestwall gypsum products with G P Pane1 rg. See "Georgia-Pacific Guide to Products for Interior Paneling