Document 93JOg2DGq9mvwOX8o4Z0kZ885
Monsanto
ATI VJCCT
J. P. Queeny Plant Sept. 21 , 1970 Aroclor Use at JFQ
TO : Messrs: P. F. Gatens E. D. Malone E. F. Take B. L. Tllford F. W. Copanas D. H. Abresch
R. L. Wagner J. A. Stepp
C. R. Schrock
R. L. Wiese
D. E. Munle
P. B. Hodges
- GO
W. B. Papageorge - 00
D. C. Malm
J. R. Savage
SUMMARY
PCB type Aroclors are used or handled in U departments at JFQ. Losses to the plant waste effluent greatly exceed Monsanto's self imposed limitation of 10 ppb and Immediate corrective action is required to meet the 12/31/70 deadline for compliance. Every means possible must be taken to prevent these Aroclors from entering our waste effluent or being absorbed in the ground. Tank washings will be sent to the toxic dump and used material will be destroyed by Incineration at WGK. The magnitude of volatile losses to the atmosphere will be determined.
INTRODUCTION
Considerable emphasis has been focused recently on polychlorinated biphenyl losses to the environment. PCB's are manufactured in the U.S. exclusively by Monsanto Company. These chemicals are a chief constituent of a series of Monsanto products marketed under the name Aroclor. Aroclors are used In a number of other products including paints, paper coatings, and a number of functional fluids.
PCB's are believed to hamper reproduction in birds and act as a low-level poison in the environment. Some are highly resistant to degradation. Consequently, there Is concern over their possible buildup In the environment.
CONFIDENTIAL
MONS
Aroclor Use at JFQ
-2-
9/21/70
WHERE AROCLORS ARE USED AT JFQ
Aroclors are used In only four locations at the Queeny Plant. Wiese Include:
A. W Building
1. Center section - Aroclor heater 2. Yard - Aroclor heater
3. Leader - Aroclor heater
B. TSC1 Department
1. Aroclor heater for the old ortho column reboller.
2. Aroclor heater for the new detoluene still reboller. 3. Aroclor seal fluid for the Nash compressor on the
HC1 recovery system.
C. Phthalyl Chloride
1. Combination reactor heating and cooling system.
D. Central Drumming
Aroclors 1232, 1242, 1248, and 3442 are used as raw materials In numerous blended products.
Ihe following Is a list of current products containing Aroclors.
Product Number
Product Name
Aroclor Used
80401 80404 80405 80406 80409 80413 80422 80448 80458
80467 80474
80475
Pydraul - 625
Pydraul - AC Pydraul - F-9 Pydraul - 150
Pydraul - 979 Pydraul - 230 Santosafe 300
MCS 153 Pydraul - 320 Pydraul - 312 Pydraul - 135 Pydraul - 540
5442
5442 1248 1242
1232 1232 - 1242 1242 - 1248 1232 - 1242
1242 - 1248 1242 1232 - 1242 - 1248 1242 - 1248 - 5442
CONFIDENTIAL
""s 093223
-3-
Aroclor Use at JFQ
9/21/70
DISCUSSION OF AROCLOR USE
Hie W Building has three Aroclor heater systems all of Which are using Aroclor 1248. Hie small homemade unit located In the center section of the building is no longer
used except 4s a backup system on rare occasslons. It is expected to be dismantled for safety reasons in the near future. Hie system known as the "yard unit" is a 1 H BTU unit located south of the X Building. This particular
unit was said to have an excellent maintenance record. Addition of makeup Aroclor to this system is extremely rare.
Hie principle source of Aroclor loss from the W Building is the "leader unit". Hiis is a 3 M BTU unit located south of the BBB Building. This unit has a bad history of losses. Considerable difficulty has been experienced with pump seals in the system. Last year the pump seals failed five times which resulted in the loss of approximately 800 gallons of Aroclor 1248. After the last failure a filter was installed on the pump lubricating line in an effort to prolong the
seal life.
Precautionary measures are taken in the department during
changeover to insure against losses. Equipment is drained
to cans and the Aroclor Is returned to the system whenever
possible. If contaminants were present, the material was
drummed for toxic dump disposal.
The TSC1 Department also has two Aroclor heating systems. There is an old system on the ortho column reboiler which
was Aroclor 1248. Hiere la also a system for the detoluene still reboller using Aroclor 1248. These systems are normally very tight requiring makeup very Infrequently. One Incident of Aroclor contamination by TSC1 occurred this year after one of the heat exchangers was rodded out. At that time a con siderable amount of 1248 was disposed of due to contamination. Hie method of disposal was not definitely determined. However, indications are that it was probably sewered.
CONFIDENTIAL
HONS 098224
-4-
Aroclor U3e at JFQ
9/21/70
DISCUSSIONS OF AROCLOR USE
Aroclor 1232 Is used as the seal fluid for a Nash compressor in the HC1 recovery system. This system seems to be a constant source of losses. Aroclor tends to buildup regularly in a portion of the systems' instrumentation. This buildup requires periodic drainage. The Aroclor is drained to a pump catchpan which goes to the sewer. Estimated losses from the TSC1 department year-to-date are 4,400 lbs. of A-1232 and 1,800
lbs. of A-1248.
The Phthalyl Chloride Department has one Aroclor 1248 system which 13 used for both heating and cooling of a reactor. Heating is accomplished by the use of bayonet heaters directly in the reactor jacket. The Aroclor is circulated through an external heat exchanger for cooling of the reactor. Losses
are about 1000 lbs./yr.
The procedures and precautions taken to prevent losses at CLHS are considered to be inadequate for the handling of all products including Aroclors. Considerable Improvement
particularly in the handling of Aroclors is required immediately. Considerable spillage occurs when handling Aroclors from tank trucks. Much less occurs when using tank cars but despite requests tank cars are not always available. Blend tanks are not washed at the conclusion of operations and succeeding blends
are contaminated with small quantities of Aroclors. The magnitude of the loss from this department to the city sewer is unknown. No satisfactory means of sampling the waste effluent has as yet been devised.
Ingeneral Aroclors numbered up through 1242 are considered
at least partially degradable and are not as serious a longterm environmental hazard as others. Aroclors 1254, 1260, and 1262 are very undesirable.
CONFIDENTIAL
MQNS 098225
r -5-
Aroclor Use at JFQ
9/21/TO
Use of 1254 and 1260 in our plant has been terminated. A substitute which is not considered a "bad actor", Aroclor 5442, is now being used. Aroclor 1248 is not one of the worst Aroclors but it is worthy of considerable concern.
SAMPLED SEWER LOSSES
Ten day continuous composite samples were taken on the north and south trunk sewers for Aroclor analysis in early June. These samples indicate the losses from the W Building and TSC1, Phthalyl Chloride Departments respectively, during this period. Results of these analyses and the theoretical average losses based on annual Aroclor consumption are as ,,follows:
Component Sample
Measured
PCB Flow Loss (pph) (gpm) (lbs./day)
North trunk sewer 46.5
554
0.31
South trunk sewer 147.0 2460
4.34
Thee retical
PCB Loss
(ppb)
(lbs./day)
3867
25.7
1244
36.7
The extremely large difference between the theoretical and measured losses may in part result from sampling errors. Since Aroclors have a high specific gravity, it is possible that the sample is not representative and that only the soluble portion is being detected.
CONFIDENTIAL
MOMS 09a^6
-6-
Aroelor Use at JFQ
9/21/70
SAMPLED SEWER LOSSES
Monthly composite samples of the main sewer effluent are being taken. The results of these analyses are:
Month
PCB
Flow
Loss
PPB 0PM Lbs./Day
June July
46 ^3.5
4338 4621
2.40 2.41
DISCUSSION
'
According to Paul Hodges, the tentative maximum PCB limit '`(set by Monsanto) for our waste effluent Is 10 ppb. This
level Is to be reaced by 12/31/70. Our losses currently are as large as experienced at manufacturing sites. Immediate steps are required If we are to meet requirements by the
deadllng.
ACTIONS REQUIRED
The following actions are required to reduce losses to
targeted level by 12/31/70. Production and PC&D have the
overall responsibility that required actions are taken.
TSD has the responsibility for providing assistance as
required.
1. Every effort must be made to prevent even the smallest drip from entering our waste effluent or being absorbed in the ground. Drip pans, containers, and curbing must be provided at all locations where a potential loss can occur.
Responsibility: .
J. Stepp, D. Abresch, C. Schrock,
R. Wagner for their respective departments with assistance from
TSD.
Completion Date: 12/31/70
CONFIDENTIAL
HONS 098227
-7-
Aroclor Use at JFQ
9/21/70
ACTIONS REQUIRED - (continued)
2. Contact of Aroclor with water Is to be avoided wherever possible since the material Is soluble In the 50-300 ppb range depending upon the specific Aroclor Involved.
Responsibility:
J. Stepp, D. Abresch, C. Schrock, R. Wagner, with assistance from TSD
as required.
Completion Date: 12/31/70
3. Blend tanks at CLHS should be washed at end of a
"
run and all tank washings containing Aroclors must
be sent to the toxic dump.
Responsibility: PC&D
Completion Date: 10/31/70
4. Aroclors which are no longer usable are to be sent to WGK for disposal. They are to be clearly marked "Aroclor For Incineration".
Responsibility: Production
,
Completion Date: Immediate
5. Operating Instructions are to be revised immediately and operating and maintenance people instructed in the
proper handling and disposition methods for Aroclors.
Responsibility: Production, PC&D
. Completion Date: Immediate
CONFIDENTIAL
MUN5 098128
Aroclor Use at JPQ
-8-
9/21/70
FUTURE WORK
1. Sample sewer from CLHS and determine magnitude of loss by 10/31/70.
2. Provide monthly composite samples of plant waste effluent for PCB analysis.
3. Follow up monthly to see that necessary corrective measures are taken.
4. Determine magnitude of volatile PCB losses to the atmosphere by 10/31/70.
R. C. Neal
/nz
MONS 098229