Document 9347GwYvK6GR4nQD08axMy39q

348 Heating Systems * b.iw, c< NORTHVALE, NEW JERSEY PACKAGED AUTOMATIC GAS HEATING PLANTS Providing Space or Volume Water Heating for Residential, Commercial and Industrial Uses 45,000 BTU/hr to 3,600,000 BTU/hr input ratings MUWTemp Multi-Temp Model R-900; 1800 lbs, 65 in. x 26 in. z 3? in. HYRDOTHERM boilers are of all cast iron construction and are exclusively designed for gas. The patented absorption unit, composed of deep-rib horizontal sections connected in zigzag, permits maximum heat transfer in minimum space with small water content. This "true" gas design results in low fuel con sumption, quick heat response, uniform heat transfer, self cleaning flue passages, and small installation space. HYDRO THERM boilers are A.GA .-approved for all and are factory assembled and wired with safety and gas controls, ready for quick installation. Boiler and controls are enclosed in an attractively finished insulated steel jacket. All boilers are tested at 250 lb hydrostatic pressure and carry a 100 lb ASMS rating which permits direct connection of boilers to city water lines as required for volume water heating applications. MULTI-TEMP, a new concept in heavy duty gas-fired hot water heating, provides any desired capacity with a multiple of HYDROTHERM units, each equipped with its own controls. True input modulation is accomplished by making boiler units respond to the return water temperature through aquastats with differential settings in the return manifold. At a cold start, all units go on; as the return water temperature rises, one or more units drop out according to their own aquastat settings ti the input is just enough to maintain the design water tem perature, effecting a year-round fuel saving of up to 20 percent. MULTI-TEMP, being composed of multiple units, offers extra protection against service interruption. Each boiler unit is shipped completely assembled to simplify field installation. CAPAcrrr bangs of hydbotherms Healing Systems . B*Oa, std 349 H||the international boiler WORKS CO. .JmWiiih 500 Birch Street . East Stroudsburg, Pa. A Complete Line of WATER . TUBE Heating and Power Boilers Internationa! water tube design assures high heat ab sorption and exceptionally low operating cost with all fuels. Boiler water circulation is positive and directed, delivering a constant payload of steam or hot water to the boiler nozzle. Every International Boiler is built to ASAfB code require- ments, and is tested and approved by a nationally recognized insurance company before shipment. Full access is provided for cleaning BOTH the fireside and waterside of all tubes without dismantling the boiler. PACKAGE BOILERS .. .fully automatic and.factory coordinated, the COMPAK Forced Draft Series Forced draft operation eliminates the need for an induced draft fan or separate controls. Available as Type FPL for low pressure steam or hot water heating and as Type FPH for high pressure steam generation in sizes from 12 to 750 hp. Write for Bulletin UflO. the COMPAK Induced Draft Series . . . noted for high thermal efficiency, quiet operation and convertibility to coal firing. Type PL'units (15 lb steam 30 lb water) . . . and Type PH units (130,160or200psig) are built in in sizes from 12 to 600 hp. Write for Bulletin 600. the COAL-PAK AUTOMATIC Bituminous Coal Fired First FULLY AUTOMATIC package unit complete' with combustion controls, automatic coal feed and ash removal system for burning LOW COST BITUMINOUS COAL eleanjy and efficiently. Type PSL (15 lbs. steam, 30-160 lb water) ana Type PSH (130, 160 or 200 psig) in sizes from 71.6 to 300 hp. Write for Bulletin 1100. the THERMOJET-Oil/Gas Fired This LOW HEADROOMforced recirculation package unit features famous LaMONT boiler design specifically adapted ri for SINGLE BUILDING low or high temperature hot water heating systems. Type TJW for operating pressures from 30 tor 600 psig in standard sizes from 250,000 to 14,000,000 Btu/hr. Write for Bulletin 1000. HEATING BOILERS--15 lb Steam--30 lb Water TYPE C--built in SBI rated sizes from 2,190 to 51,000 sq ft steam. Can be equipped with an immersion coll of in stantaneous or storage tank type for hot water service require ments. Write for Bulletin t00. TYPE IDL & BBL Boiler-Burner Units are built in capacities from 1,820 to 84,000 sq ft steam. Write for Bulletins 600 and 900. HIGH PRESSURE BOILERS--130--160--200 psig TYPE CH Of all welded construction these boilers are available in standard sizes from 8 to 363 hp--oil, gas or coal fired. Write for Bulletin 1600. TYPE IDH 4 BBH Boiler-Burner Units, including water tube boiler, steel base and induced draft fan, are shipped as a unit ready for installation of oil and/or gas burner and controls at job site. Built in standard sizes ranging from 12 to 600 hp. Write for Bulletin* 400 and 900. INTERNATIONAL-LAMONT .... HIGH TEMPERATURE WATER GENERATORS Discharge Temperatures to 430 F. Design Pressures to 600 psig BUILT-IN ECONOMIZER permits safe use of tempera ture differentials to200 F with no thermal Bboek. LOW HEADROOM reduces cost of new boiler house construction and permits installation in many existing structures. TYPE LFW available in standard sizes from 3 to 200 million Btu/hr. Completely packaged oil/gas fired units to 60 million Btu/hr. Write for Bulletin 700. THERMAL LIQUID HEATERS Safe, low pressure industrial process heat to 750" F. . . . plus temperature control to 2 F. Ideal for use with Aroclor, K Dowtherm, Mobiltherm and other thermal liquids. TYPE TJH and LFH available in standard rites from ^ 150,000 to 50 million Btu/hr. Completely packaged units in sizes to 20 million Btu/hr. Write for Bulletin 1300. See Vow Local INTERNATIONAL DISTRICT REPRESENTATIVE or write for Bulletins above