Document 91j5amV2k4rGb4gJeGZa87e67

Anniston J. T. Bell J. L. Corder A. G. Hill G. L. Jessee L. C. Lahman J. C. Landwehr H. E. Schulte W. F. Taffee General Offices H. C. Carder D. Danna (5) M. W. Farrar P. B. Hodges F. J. Holzapfel D. B. Hosmer R. E. Howard W. K. Johnson C. F. Luecke W. R. Richard W. R. Robirds C. W. Roos J. R. Savage J. E. Smith J. A. Stephens South Second St. P. 0. DeGarmo Other Locations A. H. Forsten Alvin, Texas D. w. Jackson W.G.K. COMPANY CONFIDENTIAL Anniston Plant TECHNICAL SERVICES DEPARTMENT MONTHLY REPORT Summary AUGUST 1970 Month COST IMPROVEMENT RESULTS Est. Act. ______Target% of Target $40,355 $53,015 76% YTD $558,347 $497,605 112% Organic Division The Aroclor Process Sump was put into service on 8/12/70 bettering the revised startup date of 9/1/70 by almost three weeks and the original date (10/15/70) by two months. The initial phase of the Aroclor waste effluent carbon treatment studies is complete. In the 13 day pilot run, initial concentrations of 1000 - 8000 ppb Aroclor in waste water were reduced to a range of 0-15 ppb upon passing through the series of 1" diameter packed carbon beds at an average flow rate of 25 cc/min. Over 99% of Aroclor removal occurred in the 6" deep carbon prefilter. This unusual re duction is believed to be due to the filtration of solids on which Aroclor was adsorbed. The study is presently being divided into two phases: (1) feasibility studies for con tinuous solids (with Aroclor) removal from limestone pit effluent, and (2) carbon adsorption from the clear stream at the Aroclor sump. Redesigning of Aroclor chlorinator spargers will give better chlorine distribution, resulting in reduction of free chlorine in the off gas. This is a potential cost improvement of $31,000 in chlorine usage and is an integral part of AroclorHC1 pollution abatement. DSW 551459 n - 306 .............................................CONFIDENTIAL INFORMATION "This document contains confidential information which is the property of Monsanto Company. Only those portions of the document relevant to a duly authorized individual's need to know may be excerpted for him. The report must not be sent outside the Company without written approval and the authorized recipient is accountable for its safe keeping, excerpting or otherwise disclosing of its contents and for its proper disposal. The docu ment remains the property of Monsanto Company and shall be returned within two months to its author, except upon special authorization to hold STLCOPCB4089876 ) Organic Division - continued 2. The joint Research-PR&D study on Montar 9 is progressing on.schedule. Twelve gallons of M-9, distilled by Organic Research, were used to prepare samples of high quaterphenyl (up to 50%) material hydrogenated 30%, to 100%. These samples will be used for market evaluation. EDO is 9-25-70. The low color 5460 plant test is scheduled for the week of 9/7/70. This test is aimed at reducing the color to 1.25 NPA. The delayed-promoter injection phase of the Polyphenyl Pilot Studies has been delayed by a burned-out reactor heater and then a coked reactor. The new reactor has now been installed and was started up on 8/31. Construction for the expansion of HB-40 (CEA 1482) is approximately two weeks ahead of schedule with startup tentatively scheduled the week of November 16. Revised design and estimate for Bulk Plasticizer Terminal was reviewed with J. E. Smith. The following HC1 recovery improvement work has been completed or is in progress. 1. Pressure by-pass loop installed by CED on CEA 2080 was relocated, calibrated and is presently working well, eliminating sewering of acid through this line. 2. Drain taps were installed on carbon towers to allow batch pretreating of fresh charges to eliminate iron. Previously total production was sewered during pre treatment. An HC1 fume collection/scrubbing system for docks and storage tanks has been pro posed. The project will significantly reduce water load to sewer and subsequent treatment for PCB removal. PNP had a very good production month (1,862,860#) with excellent on-stream time (93.7%). Agricultural Division Tests of Process Amendments "Chlorination in the Presence of Acetone" and "Hydrocarbon Dilution of Still Residue" was restarted on 8/10/70. The residue hold tank temperature was maintained at 60-70C., compared to 50-60C. normally. Revised operating conditions were not successful in preventing residue from precipitating from the diesel fuel. Higher temperatures apparently caused the formation of some very large balls in the hold tank and the test was stopped. The "Hydrocarbon Dilution" amendment was then tested independently. Results to date indicate increased yields and that the diesel fuel is a good residue pump-out aid. No problems have been experienced in the hold tank or in burning the residue as yet. Experimental operation of #1 Parathion intermediate still verified predictions from process analysis of higher yields from controlling the profile of steam input with time. An average improvement of 200# per batch was achieved, worth $35,000 on methyl parathion at 1971 rates. DSW 551460 STLCOPCB4089877 > 3. Quality Control The Plant Quality Score was 87.9, up 1.9 from July, with a YTD score of 86.0 against a target of 95.0. Improved Aroclor 1242 uniformity and PNP quality were proved. Pollution Control Monsanto has been dropped as a defendant in the class action suit by Bass Anglers Sportsman.Society against over 200 industries in the State of Alabama. Aroclor in plant effluent showed a sharp increase in August, concurrent with high solids out of the limestone pit. Work has begun on an interim HC1 neutralization facility so that the existing pit can be decontaminated and improved without interruption in waste water treatment. DSW 551461 STLCOPCB4089878 ) 4. PLANT LABORATORIES ANALYTICAL AND QUALITY CONTROL - S. O. Kemp Complaint Report Quality Number ATL-18-P NY-51-P Material Muriatic Acid Santowax R __________Customer______ F. H. Ross Raybestos-Manhattan Reason Assay Lumps YTD Quality Complaints/100 Shipments 0.32 Target 0.20 DSW 551462 STLCOPCB4089879 ) 5. COMMUNITY RELATIONS, PERSONNEL, RECRUITING AND DEVELOPMENT Community Relations 1* J. C. Landwehr attended the Air & Water Resources Sub Committee meeting in Birmingham, Alabama on August 14. 2. Dr. Lowell Taylor and Group from Auburn University visited to discuss recruiting and Co-Op program with Auburn University on August 19. Personnel Development 1. S. O. Kemp spent August 27 and 28 in St. Louis on special training for PCB analysis on Aroclor 5460 with E. M. Emery at Organic Research. 2. J. T. Bell and J. L. Brown attended Coaching and Appraisal course at Holiday Inn - Oxford on August 13 and 14. 3. T. W. Lawrence transferred from Technical Services to position of Plant Safety Engineer on August 31, 1970. Visitors 1. J. E. Smith, St. Louis, visited concerning Bulk Plasticizers Terminal - August 4 and 5. 2. J. R. Savage, St. Louis, visited to review Cost Standards - August 17. DSW 551463 STLCOPCB4089880 > 1970 DISTRIBUTION OF TIME BY TECHNICAL SERVICE EXISTING PRODUCT TECHNOLOGY IMPROVEMENT NEW PRODUCT EVALUATIONS MAJOR PROJECT SUPPORT PROCESS CONTROL IMPROVEMENT . ' 70 60 50 40 PROJECT DESIGN PROCESS MAINTENANCE TECHNOLOGY AND TECHNICAL SUPPORT TECHNICAL MANPOWER PLANT IMPROVEMENT PROGRAM REAL ESTATE MANAGEMENT STLCOPCB4089881 ORGANIC DIVISION 1970 TSD COST IMPROVEMENT FUNCTIONAL FLUIDS - TAR . EST ACT JAN FEB MAR . APR MAY JUN JUL AUG SEP OCT NOV DEC Disposal of Liquid Montar #3 Aroclor Still New Burners #2 Still Entrainment Separator TAR EST ACT TAR EST ACT TAR EST ACT 15.00 600 600 1080 0 C 1080 ,0 o 1500 1080 0 0 1080 0 0 1080 1080 1080 U 0~ 0 500 500 3000 ~` 0 0 1080 1080 3000 1080 1242 Distillatio -l Productivity tar EST ACT 1500 1500 1500 1500 1500 1500 isod 1500 1500 0 100 1000 1520 2565 2000C 100 1000 1520 2565 1500 TAR EST ACT TAR PLASTICIZERS EST ACT Flaking & Drum ming Facilities Headcount Solid Aroclor Instrumentation TAR EST ACT TAR EST ACT TAR 3000 3000 3000 3000 3000 3000 2000 2000 2000 1000 1000 1000 3750 0 1000 TWO 1000 3750 0 0 3750 3750 3750 3750 0 nr 0 00 2250 2250 2250 3750 2250 3750 2250 3750 2250 Sandvik Belt EST ACT Add Tray Strip ping Sections to Santowax TAR EST ACT TAR Cl2 Bulk Handling Facilit . les EST ACT Solid Aroclor Expansion TAR EST ACT Chlorinator Back Pressure TAR EST ACT 2000 3500 3500 00 0 4580 4580 4580 4580 4580 4580 4580 0 00 0 0.0 00 0 2000 -20JXL 2onn 3550 1950 3440 3550 3050 3440 30000 5000C 49500 5000C 10000 36000 24000 |l7900 20000 519.0C 5590C 1050C 38500 23500 24700 30000 360 360 4580 360 4580j | ** 1 J 360 TAR EST ACT TAR EST ACT TAR EST ACT .. -- - TAR -- ----- EST ' ACT - ------ -- [ DSW 551465 1_____ 1-....... ______________ STLCOPCB4089882 ) ' ORGANIC DIVISION 1970 TSD COST IMPROVEMENT FUNCTIONAL . FLUIDS & PLASTICIZERS Aroclor Warehouse Reduced Headcount Unproved Santowax Yield TAR . EST ACT TAR EST ACT TAR EST ACT HB-40 Reduce Nickel Catalyst Usage TAR EST ACT Substitution of Santowax C for Santowax R TAR EST ACT TAR EST ACT GENERAL CHEMICALS TAR EST ACT Biphenyl Cool^- TAR ing Water EST Treatment ACT TAR PftiP ' EST Modify Acidifies Dump valve Svste m act Install Entrain- TAR ment Separator - EST Production ACT Optimize Reactoi Variables-PNP TAR EST ACT Re-use Well Water TAR EST ACT Untargeted PNCB Heel Credits TAR EST ACT HC1 HCl Catch Tank & Coalescer 150 M Gallon Storage Tank TAR EST ACT TAR EST ACT HCl Instrumentation TAR EST ACT TAR EST ACT TAR EST ACT JAN FEB' MAR APR MAY JUN JUL AUG SEP OCT NOV DEC (AFE ECTIN 3 BOT1 I BUS! NESS GROUP S) innn 1000 1000 1000 1000 1000 1000 10Q0 1000 1160 4000 4000 4000 4000 5900 2800 5800 4000 4450 2800 5800 4000 700 700 700 1330 - 525 1230 1335 525 2080 700 425 565 4000 4000 4000 4000 400Q 97C 663C 97C 700 0 C 700 700 G 20Q0C 4Q0Q 2 QQQ( - 600 670 670 3150 520 520 (BIP HENYL 600 680 680 600 580 580 3150 3150 1277 2164 3016 2164 PNP HCU 600 600 600 625 625 '600 67q 675 62625 600 440 440 600 290 29C 625 625 625 625 625 625 625 625 625 5500 5500 5500 5500 00 0 463f 463.0. -A5-1Q. -4600. .4630- 121 1604 0 1525 1780 12' ' 1605 0 1525 4630-. 500 625 625 5500 5500- 46.30 ) 500 L*) 5Q0 \ l 5700 2500 2500 5100 4300 4300 2275 563 3078 1650 920 2275 563 3078 1650 920 5700 5700 5700 57Q0 7560 9000- 1030C 6545 7560 9000 1030C 6545 4300 4300 4300 4300 4300 410 410 550 4300 4300 4300 4300 4300 4300 1875 4000 1230C 4000 1230C 4300 4300 4300 4300 1875 '1875 1875 1875 1875 3440 6500 3940 8160 3440 6500 3940 - 1875 1875 1875 oS*6* f | I STLCOPCB4089883 . ORGANIC DIVISION 1970 TSD COST IMPROVEMENT PLANT WIDE Improve Plant Power Factor Central Air Compressor Chlorine Plant Shutdown' RTN Cooling ' Water to Tower Cooling Con veyor - P?S5 Total Organic Month - M $ Total Organic YTD - M $ JAN TAR EST ACT TAR EST ACT TAR 950 EST ACT 900 940 TAR EST ACT TAR 19900 EST 19900 ACT 19900 FEB MAR APR MAY JUN 950 900 914 950 9T6 840 950 790 790 950 S7KT 810 950 533 845 19900 19900 19900 19900 19900 19900 19900 19900 19900 9950 9950 9950 JUL AUG " SEP OCT NOV DEC . . 1000 1000 1000 - TAR EST ACT 25 25 25 25 25 25 0 TAR EST ACT TAR EST ACT TAR EST ACT 40.6 72.1 96.88 58.07 44.62 27.97 34.12 30.52 30.88 64.68 51.68 51.68 36.29 94.54 103.6 ~7T76T 53. 58" 30.33 37T63 36.33 99.86 109.1 70.89 77.98 42.22 35.03 TAR 40.6 EST 36.29. ACT 36.33 112.7 209.6 267.6 312.3 340.2 374.3 404.9 435.7 500.4 552.1 603.8 130.9 239.8 315.7 390.8 437.7 467.7 510.0 136.2 245.3 316.2 394.1 437.3 472.4 DSW 551467 STLCOPCB4089884 > AG DIVISION 1970.TSD COST IMPROVEMENT PARATHIONS TAR EST ACT JAN FEB MAR . APR MAY JUN JUL AUG SEP OCT NOV Replace #3 Chlorinator TAR EST ACT 4860 4860 3500 2340 2340 3500 0 0 3500 0 0 3500 0 Improve C^Still Yields TAR EST ACT 3000 0 0 3000 0 .0 3000 0 d 3000 0 3000 3000 Increase Chlor- TAR inator Coolings EST ACT 8500 8500 ~cr 8500 Acetone Recovery Chlorine Unloading Optimize Methyl TAR EST ACT TAR EST ACT TAR 2800 1957 1957 2250 3634 3634 2800 1069 1069 2250 4237 4237 2800 1225 1225 2250 3350 3350 2800 1935 - 1935 3200 1406 1406 2800 130 130 3200 3431 3431 3000 2800 715 715 3200 2430 2430 3000 2800 0 0 3200 1750 1750 3000 2800 0 3200 2710 1500 2800 2800 . 2800 PNP/PCT Ratio Optimize Ethyl PNP/PCT Ratio Change Cooling H.,0 - Item 737 4 EST ACT TAR EST ACT TAR EST ACT 500 0 d 200 310 310 750 2641 2641 200 230 230 750 0 0. 200 270 270 00 00 00 0 500 Untargeted: Plant Test - TAR EST ACT 2430 2430 5270 5270 TAR EST ACT Total AG Month M S TAR EST ACT 5.75 5.90 5.90 6.0 8.17 8.17 6.0 4.85 4.85 6.0 10.63 10.62 15.5 XX 2. 11.2 15.5 3.15 3.15 15.5 1.75 1.75 22.5 277T 14.3 14.3 3.3 Total AG YTD M $ TAR EST ACT 5.75 11.75 17.75 23.75 5.90 14.08 18.92 29.55 5.90 14.08 18.92 29.55 39.25 54.75 40.73 43.87 40.73 43.87 70.25 92.75 107.1 121.4 45.62 43.33 45.62 124.7 TAR EST Total Plant Month M $ ACT TAR EST ACT 46.35 42.19 42.23 78.1 102.8 108.0 102.9 64.07 108.5 "81': 02 113.9 81.52 60.12 43.47 49.62 53.02 45.18 83775' 46.72 "37"."08 40.36 89.15 45.36 36.78 78.98 54.98 Total Plant YTD M $ TAR 46.35 124.5 227.3 291.4 EST 42.19 145.0 258.8 345.3 ACT 42.23 150.3 264.2 345.8 351.5 395.0 444.6 431.5 481.6 513.3 434.9 481.2 518.0 497.6 542.8 621.8 558.3 676.7 DEC 50( C 125.: 52. U 728.S DSW 551468 STLCOPCB4089885