.......................... has been used successfully since 1941 as a liquid phase heat transfer medium at atmospheric pressure and temperatures up to 600F.
The compound, essentially tetrachlorobiphenyl, is a fire-resistant and non corrosive liquid, which does not crystallize at low temperatures. Handled properly, in well-designed forced circulation heat exchangers which avoid localized over heating damage, the fluid gives satisfactory continuous service for many years without replacement.
Most significant, Aroclor 1248 is practically non-flammable. In one in stallation of record, a ruptured pipe spewed the hot fluid into gas flames: the fluid failed to ignite!
For general heat transfer, Aroclor 1248 has several other important qualities: it is highly mobile and can be readily pumped at temperatures as low as 50F. If cooling is necessary, the heat transfer fluid can be put through a water cooler to be used as a coolant... using this single fluid for both beating and cooling.
Aroclor 1248 transfers heat (up to 500F.) as a liquid. This liquid phase heat transfer malces it unnecessary to use the expensive pressurized equipment required by a heat transfer medium that operates as a vapor. Ardclor 1248 operates safely and efficiently with gas-fired, oil-fired, or electrical heat sources. It is used successfully in the following types of applications ....
053170*
TOWOLDMON0036135 WATER_PCB-00020604
Chemical Processing Equipment, particularly for reacting flammable materials Cooking of Alkyd resins, varnishes, waxes Plastics molding, extruding, calendering Rubber processing Heating asphalt Food Processing, including potato chip and doughnut frying in vegetable oils Processing titanium, magnesium, other non-ferrous metals Fabrication of magnesium and aluminum honey-comb structures for aircraft 9 Indirect heating in dyestuff manufacture 9 Heating of corrugating rolls Indirect heating of distillation equipment Saponification oF fats Calcining Ovens O Impregnation and lamination of fibrous materials
0531705
TOWOLDMON0036136 WATER_PCB-00020605
table I
Appearance
Absolute density, g./ml.
Absolute viscosity, centipoises
Thermal Conductivity, Btu./hr./sq. ft/T./ft
Spec, Volume, ml./g.
PncflcaDy eatatas mobfle Bqnid.
Temperature "Cetffrade 'Fahrenheit
1.44 30 86 1.41 60 140 U7 10O 212
127 200 392
1.17 300 572
112J 30 86 17.5 GO 140 4.2 100 212 0.99 200 392 0.47 300 572
0.0571
30
0.0564
60
0.0555
100
0.0534*
200
0.0512*
300
'Extrapolated Data
86 140 212 392 572
0.696 30 0.709 60 0.728 100 0.787 200 0.860 300
86 140 212 392 572
CONTINUED
0531706
TOWOLDMON0036137 WATER_PCB-00020606
H55SS!
(Table 1. cont.)
Spec. Heat, cal./g./C.
Vapor Pressure, mm. Hg.
Distillation Range, ASTM D-20 Rash Pt., Cleveland Open Cup,
ASTM D 92-45 Fire Pt. Cleveland Open Cup,
ASTM, D 92-45 Pour Pt., ASTM, D-97 Average Coefficient of Expansion
cc./cc./F.
0.283 0.297 0.326 0.355
Centigrade 50
100 200 300
0.00037 0.16 2.9 18.0 350.0 ,,
37.8 100 150 200 300
Fahrenhelt 122 212 392 572
100 212 302 392 572
345-385
652-725
193-196
379-384
None
0.00037 0.00038 0.00041 0.00044 0.00047 0.00052
--
-7
--17.8 to 37.8 37.8 to 93.3 93.3 to M9 149 to 204 204 to 260 260 to 316
--
19.4
Oto 100 100 to 200 200(o 300.; 300 to 400 400 to 500 500 to 600
PHYSICAL CHARACTERISTICS
of
AROCLOR 1248
A complete knowledge of the physical
characteristics of heat transfer media is
H-
'
highly1-' fcssential to their satisfactory
i'
application in a heat exchanger. These
physical, constants have a major hearing
on the equipment design, its mainte-
nancCj'and its operation. . ' ` .
The following figures and charts give basic physical data on Aroclor 1248.
0531707
92
Tr r
X1|
r
t
r
E E
V r
r
F
100 j-
f
5
TOWOLDMON0036138 WATER_PCB-00020607
DENSITY OF AROCLOR 1248
(Top axis, lbs./cu. ft.; bottom axis, gm./ml.) DENSITY lbs./cu. It.
TEMPERATURE F.
Figure 1
BBsmiju&HE!:
0531706
Matte
TOWOLDMON0036139 WATER PCB-00020608
TEMPERATURE F.
0
100 200
300 400
500 600
VISCOSITY OF AROCLOR 1248
VISCOSITY UNITS
1
I TOWOLDMON0036140
WATER_PCB-00020609
VISCOSITY OF AROCLOR 1248 (Saybolt Universal Seconds)
TEMPERATURE, DEGREES FAHRENHEIT
0531710
BE
TOWOLDMON0036141 WATER_PCB-00020610
HEAT CAPACITY and Its Relationship to Density
Systematic errors exist in the various accepted pro cedures for making specific heat determinations. Consequently values may vary depending upon the procedure used. In practical operation, it frequently appears that the values for Aroclor 1248 shown in Figure 4 are somewhat low. Consequently, although these values have been accurately determined, they may be regarded as conservative.
When comparing the specific heat values of Aroclor 1248 with corresponding values for other heat transfer fluids, it is important to note that the density of Aroclor 1248 is much higher, relatively, than the density of other liquids used for heat transfer. Accord ingly, when comparison of heat capacity is made on a
volume basis (which is most pertinent in equipment design and efficient operation) the heat capacity of Aroclor 1248 shows itself to better advantage than by direct comparison of speeific heat values.
Although specific heat values are important, they represent only one of several important constants that enter into the equations for calculating over-all heat transfer efficiency. -
Through the use; of these conservative heat capacity values, it is possible that equipment engi neered from such data might be slightly "over designed." Tins may be one of the factors that accounts for the exceptionally good operating performance of a number of highly successful commercial applications.
05J1711
TOWOLDMON0036142 WATER_PCB-00020611
SPECIFIC HEAT OF AROCLOR 1248 {Bin. per lb. per degree F.)
^ri^ga^u^^^iiiafta^aagsimgarit^^^saaaiiaMir '"""'"
^Sai3^8S&y^33&S&a^&2^yi2SBEfai
is^^a^a^jyil^^BESgeaiaaiaaBHHi
9I)&h&3L!.>5 s
_____ ___________ ___ _______________
........ --
--
--*'
wijriTi&spsrv ^iwmrmnmr
iu
lei^iuMii i^j5!>st
i^i'
^v.*/ jlLitffiiO i*
iJi-dL2^&U
t tS
,*4/*L S_fifAij yyny^yi;i:^Li__________
tJ^.i.t 'jr?^fejt5tejaaeSg>>^aLaiktto^aySi
mi2'|u!^3^K'3m?r ^n\
Ka
_...;^SJSt'
_____
..
__________
IttHMMay......______
5SS
SPECIFIC HEAT Etu./!b./T.
0531712
SS^'jgilSMbkiiaL^v^aaiiMBBawMawBiajbaiMi^^
TOWOLDMON0036143 WATER_PCB-00020612
Temperature c. F.
0 32 10 50 38 100 66 150 93 200 121 250 149 300 177 350 204 400 232 450 260 500 288 550 316 600
TABLE n HEAT CONTENT
of Aroolor 1248
Specific Heat Btu./lb./F.
.269 .272 .280 .288 .295 .303 .311 .319 .327 .335 .343 351 1 359
/
Heat Content Btu./lb. 0.0 4.85 38.65 $2.85 ,47.43 < '62.38 77.58 93.48 109.66 126.21 143.17 160.52 178.27
U531713 10
TOWOLDMON0036144 WATER_PCB-00020613
THERMAL CONDUCTIVITY and VISCOSITY
The thermal conductivity values of Aroclor 1248 are shown in Figure 5. The curve shows this value over the operating temperature range, from 50F. to 600F., of Aroclor 1248.
As freshly charged into a heat exchanger, Aroclor 1248 has an initial viscosity of 74 (S.U.S.) at 130lF. which corresponds to a viscosity of approxi mately 5000 (S.U.S.) at 50F. -- which temperature is assumed for practical purposes to be-about the limit at whjch Aroclor 1248 can be conveniently pumped with a centrifugal pump.
1 j The following table shows a comparison of the initial viscosity and the viscosity after a year's con tinuous service at 600F. in a LaMont forced circu lation heater:
TABLE in >-
:: Original
Appearance Specific Gravity, 65 C. Viscosity. S. U. S. at 130T.
Colorless liquid 1.410
74.0
After one Year of service at 600F.
Dark 8rown Liquid
1.418
83.5
Although Aroclor 1248 tends to darken in use, this darkening is not harmful and does not indicate decomposition. In actual use at Monsanto, it has not been found necessary to replace the fluid after seven years of continuous use; additional fluid is only added as necessary to make up spills or leaks.
In Figure 6, the horizontal line indicating vis cosity limit of pumpability at 50F. shows that the rate of viscosity increase based on a year's continuous service should permit Aroclor 1248 to serve approxi mately four years before increased viscosity may inter fere with its pumpability when cold. In practice, Aroclor 1248 has given satisfactory pumpability for much longer periods. A simple S.U.S. viscosity deter mination by the ASTM-D-88 method can be used for periodic checks on the fluid.
0531714
TOWOLDMON0036145 WATER_PCB-00020614
THERMAL CONDUCTIVITY OF AROCLOR 1248 (Dotted extrosiou indicates extrapolated data)
Figures 12
THERMAL CONDUCTIVITY. Btu./(Hr.)(ScJl) (f.XFL)
0531715
TOWOLDMON0036146 WATER_PCB-00020615
EXPECTED MINIMUM SERVICE LIFE IN A FORCED CIRCULATION HEATER
TOWOLDMON0036147 WATER_PCB-00020616
STABILITY
Aroclor 1248 is an extremely stable chemical com pound. Tests over long periods of time have shown that 600F. is a safe maximum temperature for continuous operation in heaters that are properly designed and operated to eliminate intense, localized overheating. At this temperature the fluid is 52F. below the initial temperature of its boiling range, and consequently re mains a liquid.
Near its boiling point Aroclor 1248 tends to dehydrohalogenate to a very slight but measurable degree. If this occurs as a result of accidental over heating, the small amount of HC1 gas evolved tends to pass through the vent tank without harm to the equipment provided that die system is dry.
Experimental observations using ideally-suited heat exchangers operating at a temperature of 650F. with imposed nitrogen pressures of 30 and 70 psig. showed that application of pressure did not prevent this small amount of thermal decomposition, which also occurs when the material is heated above 600F. at atmospheric pressure.
When heated continuously at 650T. under nitrogen pressure a gradual increase in the viscosity of the fluid occurs indicating that its service life would be limited to about 6 months to one year.
Results of operating at 600F., however, with out imposed nitrogen pressure indicate Aroclor 1248 can be heated continuously at this temperature for about 4 years before any viscosity increase could be expected to interfere with its pumpability at 50F. which is slightly below normal room temperatures.
Provision should be made to prevent water contamination of the system. If the system becomes contaminated with water, any HC1 liberated by local ized overheating may dissolve in the water film which will float on top of Aroclor 1248 in the expansion tank. The acidic solution thus farmed can cause corrosion. It is recommended that moisture be eliminated from the expansion tank by insj^Jling a moisture trap or by sealing the tank and applying 15 to 30 psig. of nitrogen gas. With exception of the expansion tank, the system should be kept full of Aroclor 1248 at all times to pre vent formation of air pockets where moisture may condense when the system cools off between periods of operation.
Many years of practical operating experience have shown that Aroclor 1248 is virtually non-corrosive to valves, piping, tanks, and jackets made of cast steel, steel, or stainless steel. In actual use, brass valves have been used satisfactorily.
0531717
TOWOLDMON0036148 WATER_PCB-00020617
SAFETY of OPERATION
Aroclor 1248 can be considered a non-flammable liquid; no fire point is obtained by the Cleveland Open Cup method on heating to its boiling point (65CPF.). The spontaneous ignition temperature(2) is 1,299F.
In actual use, the following reported accident in a heating system demonstrates the fire resistance of Aroclor 1248 and the freedom it offers from the hazard of fire propagation. An operator's failure to start the circulation pump when thejgas heater was on resulted
in excessive coil temperatures. The line containing Aroclor 1248 sagged into the fire chamber. A weld rup tured and Aroclor 1248 poured into the red-hot Fire chamber in contact with the flame. Dense smoke and fumes arose from the heater but there was no external fire. After the gas flame was cut off, the smoking stopped.
Insurance authorities allow the use of Aroclor 1248 heaters in many locations with a minimum of protection. No fire walls are required to isolate the heaters.
Aroclor 1248 has a low vapor pressure. In sys tems that employ a vented expansion tank, the loss due to evaporation is not measurable. If Aroclor 1248 in the expansion tank would reach a temperature of
266Ft; the vapor pressure of the fluid would be only 1 mm. of I-Ig.
SAFETY OF HANDLING
Aroclor 1248 is an inert, unreactive liquid. If it is spilled on the skin, there are no noticeable ill effects. It is advisable, however, to wash the skin with soap and water after contact.
A skin burn resulting from accidental contact with hot Aroclor 1248 should be treated in the normal manner for hot oil burns. Any liquid adhering to the burned area need not be removed immediately unless treatment of the bum demands it. If the bum must be cleaned, soap and water or repeated washings with a vegetable oil (olive oil) may be used.
The vapors emitted by Aroclor 1248 heated to elevated temperatures are injurious on prolonged ex posure and should not be breathed. It is indicated that 2.0 mg. of Aroclor 1248 per cubic meter of air is the maximum safe amount permissable in workrooms. In commercial heat transfer installations, it is presumed that Aroclor 1248 will be used in a closed system free from leaks. Accordingly, there should be little or no opportunity for workers to come in contact with Aroclor 1248 vapors.
A bibliography appears on page 32.
0531718
TOWOLDMON0036149 WATER_PCB-00020618
HEATER
i
i.i
The most significant factor to remember when selecting or de
signing a heat exchanger for Aroclor 1248 is this: Aroclor 1248 transfers heat while in liquid form, at the maximum
recommended temperature of 600F. for continuous operation, which is approximately 50F. below the boiling point. Conse
quently, Aroclor 1248 does not form vapor to accelerate convection
circulation. Ordinary fire-tube or water-tube heaters which depend
solely upon convection perform satisfactorily only at relatively
low temperatures.
When temperatures of 500-600F. are required, a forced circu
lation type heater is recommended. A satisfactory type of heater design
would consist of a specified number of tubeSstn parallel, properly orificed
to provide a high velocity fluid flow of 8 tp. 10 feet per second. These should be spaced to permit uniform heat absorption throughout their
entire length. A typical construction is shown in Figure 7.
In its fabrication, the heater should be ASME Code all-welded
construction, conforming to state and local ordinances. Tube joints, which
in an ordinary steam heater would be the expanded type, must be seal-
welded to prevent leakage. All connections larger than %" should be
flanged connections, since ordinary threaded pipe connection is not suited
for Aroclor 1248 service. Spiral-wound stainless steel and asbestos com
bination is recommended for sealing joints and plugs. Drain valves should be installed at all low points on the heater and
the valves must conform with ASME requirements for "blow down" valves.
0531719
TOWOLDMON0036150 WATER_PCB-00020619
3d
Since a heater operating on Aroclor 1248 is completely filled
an efficiency of from 75 to 80%. Heaters of the straight con
se
with liquid, costly Iiquid-'level controls and condensate return
nector type show efficiencies of 65 to 75%, depending upon the
hr
pipes, fittings, traps, etc. are completely eliminated.
discharge temperatures.
Heaters can be provided with any desired kind of firing.
Portable and small size stationary units are frequently elec
HEATER CAPACITIES
3d
trically heated; larger units may be gas- or oil-fired. In installa
Heaters using Aroclor 1248 (gas- or oil-fired) are available in
=h
tions where an open flame presents a fire hazard, to meet
output capacities ranging from approximately 250,000 Btu. per
il-
insurance requirements the heater may be installed in a sepa
hour to large units rated over 10 million Btu. per hour. A heat
oe
rate building with piping carrying the hot Aroclor 1248 to the
flux density (or heat energy input) of approximately 5,000 Btu.
:d
point of use. Properly constructed transmission pipes may ex
per hour per square foot of tube surface is regarded as
tend for hundreds of feet. n-
satisfactory.
For lower output rate, electrically-heated units are
HEATER EFFICIENCY
favored, employing watt densities of 12 to 16 watts per square
id
Forced circulation heaters with integral economizers will show
inch of element area.
053I70
.'BWWMBWW
TOWOLDMON0036151 WATER_PCB-00020620
THE USERS
The "users" or recipients of lire heat at tl>c point of processing can He any type of heating pan, pinion, jacketed kettle, or coils of steel or stainless steel construction. Ordinary low pressure construction is satisfactory, since the pressure imposed on the Amclor 1248 seldom exceeds 50 psig. In the user, however, ft is important that all-welded construction be used. Threaded connections may allow leakage of the hot fluid. As in the heater, all connections $4" and over should be flanged and all joints sealed with spiral wound stainless steel and asbestos gasket material. Alloy bolts should be used to secure flanges. A typical system with several users shown in Figure 8.
IB
' STORAGl TANK
Figure 8
0531721
TOWOLDMON0036152 WATER_PCB-00020621
THE PUMP
For most systems, cast-steel centrifugal pumps with water-
cooled stuffing box and bearings are to be preferred. However,
high temperature centrifugal pumps with mechanical seals are
now available which give excellent performance. In some in- <
slallations, immersion pumps have been used. Whatever type
is selected, the pump capacity and pressure head must be
sufficient to circulate the volume of fluid at the rate the
particular installation demands.
To avoid shaft trouble and leakage at the seals, it is
important to provide adequate expansion joints and to support
the piping in a manner to avoid stresses on the body of the
pump. Direct-connection pumps driven by 1,750 rpm. motors
are most commonly used. Each pump should be fitted with a
positive differential control to switch off the burner in case of
pump failure.
When a new system is first put into operation, a slight
leakage may be noticed at the pump. It is not advisable to
tighten the pump gland, however, until the system has heated
up close to the temperature of operation.
PIPING LAYOUT
The most important factors in the piping layout for Aroclor 1248 systems are (a) proper sizing for the required flow rate and (b) minimizing pressure drop. Because the sys tem will undergo temperature changes, adequate expansion joints and loops to relieve, expansion and contraction stress are essential.
All pipe lines and connections should be of extra heavy or Schedule 80 welded construction meeting A.S.M.E. require ments. Flanged joints should be used as sparingly as possible to minimize potential leak points.
All valves and controls should be cast steel construction with stainless steel seats. Pipe lines should be well insulated and those exposed to temperatures below 70F. should be steam jacketed.
AH high points in the piping system should be provided with vent valves; all low points should have drain connections. Piping should be well anchored at frequent intervals, particu larly near expansion loops, to prevent vibrations.
Figure 9 shows a typical piping diagram that illustrates the important features of an Aroelor 1248 piping system. These may be varied to suit the installation.
S5&5
TOWOLDMON0036153 WATER PCB-00020622
THE EXPANSION TANK
The expansion tank should be large enough to accom modate about 20% of the total volume of the entire system, including the fluid content of the heater, piping, and all heatusers. Tank should be sized to be %-full when system is cooled to 70F. and %-full when system is at maximum operating tem perature. Expansion tank should be fitted with a sight glass at the "full" range and a float-operated low-level switch to shut off burner in case of accidental fluid loss in the system.
The expansion tank should be mounted on a platform high enough to support die liquid reservoir at least six feet higher than the highest point in the piping system.
THE FEED and DRAIN PUMP
To eliminate manual filling and draining of the heating system, it is recommended that a small 2-to-5 gpm. positive displacement pump be installed at some convenient point to pump the Aroclor 1248 into or out of the system.
CONTROLS
Controls for heating systems using Aroclor 1248 should be installed both on the heater itself and on die heat-using units. A wide variety of thermo-operating controls are available and any reliable standard equipment is satisfactory.
Heater controls should be installed to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to main tain the Aroclor 1248 at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off* or "high-low" con trollers; larger units may operate more uniformly if equipped with modulating temperature controls.
User Controls should be installed to regulate the flow of the heat transfer fluid in direct proportion to the heat-con sumption of die heat-using equipment. In a multiple-user sys
tem, separate controls should be installed on each consuming
unit, to assure the proper heat-delivery.
Safety Controls. In addition to activating controls, the
heater must also be fitted with t)je proper safety controls to
meet the A.S.M.E. requirements. Safety controls should
include:
. 1. A high temperature limit control operating at
the heater outlet tofchut off the burner in the event of an excessive temperature rise. 2. A suitable low-limit temperature control to hold the burner at {ow fire until the Aroclor 1248 in the system reaches a temperature level of 180F. u
The low limit temperature; control is essential because
the viscosity of Aroclor 1248 is rather high at normal room tem
perature. To avoid localized overheating upon start-up, it is not
advisable to apply full heat from the burner until all the fluid
in the system has attained a viscosity that allows good flow and
unimpeded circulation. Cold start-jips require slow up-heats.
Burners should be equipped with automatic ignition
controls and flame failure controls. In wide-range firing opera
tions, an over-fire draft control vVill increase the economy of
operation. Induced draft fans are adother factor which should be
considered as a means of avoiding the expense of high chimneys.
Where they are needed throughout the system, good
quality recording or indicating gauges should be installed.
COOLING EQUIPMENT
Where fast reduction of temperature is required, suitable
air- or water-cooling installations !may be used. If the cooler
is to be a water-type unit, it is suggested that stainless steel
. tubing be used for the coils to avoid corrosion on the water side.
1 If a cooler is installed in the system, low tein[X`rnture limit con
trols should also be installed to ayoid excessive cooling that
might raise the viscosity to die point of impeding the circulation
in the system.
f
0531?23
TOWOLDMON0036154 WATER_PCB-00020623
FILTERING EQUIPMENT
When heating systems operated on Aroclor 1248 are run continuously near the recommended maximum temperature of operation (600F.), it is advisable to provide a filtering device that can be attached to the drain line of the storage tank. In this way discrete particles of dirt that may get into the system can be f filtered ot periodically. This is an advisable maintenance step since it will eliminate die danger of dirt clogging the valve seats or lodging in parts of the Control mechanisms.
A small portable filter such as those manufactured by Honan-Crane Corporation (Lebanon, Ind.) or Sparkler Manufac turing Company (Mundelein, III.) is quite satisfactory.
CONNECTIONS and GASKETS
v In a system operated on Aroclor 1248, welded connec
tions are preferable; threaded screw connections should be
avoided wherever possible.. This precaution will minimize leaks
with consequent make-up. iAll connections %" and over should
be of die flanged type fastened with alloy bolts to prevent frozen
connections. Steel connectors should be used for all instruments
and controls. For gasketing-, spiral wound gaskets of corrugated
stainless steel and asbestos, combination should be used on all
flanged connections.
.
TESTING and CLEANING THE SYSTEM f.
When a new system has been installed, it is essential to
test the entire system hydrostatically for leaks, and to wash out
all the lines to remove dirt, oil films, or pipe scale. Both the
cleaning and the testing can be done in a single operation
as follows:
,
Fill the entire system with a water solution containing 5 pounds of soda ash and'. 5 pounds of caustic soda for every 1000 pounds (120 gal.) of water used. Thoroughly vent the sys
tem at all of the highest points in the piping system to assure complete filling . . . then start the circulating pump. With the pump running, the entire system is next inspected for leaks.
Next, turn on the burner at low-fire rate and raise the temperature of the wash solution to 180F. This hot wash solu tion should be circulated continuously through the entire system (heater and all users) for at least 24 hours. At regular intervals a portion of the solution should be drained and replaced by fresh water. This partial draining should be continued at regular in tervals until the drainage from the system is clear.
At the end of the 24 hour period, the temperature of die circulating wash solution should be brought up to 240F, and the fire turned off. The whole system should then be drained and all vents in the piping opened. Residual heat will dry the pipes and the heater through the vents, which should remain open until inspection shows that the system is entirely dry. When all traces of water have dried out, the drains and vents are closed.
Aroclor 1248 is then charged into the cleaned, dry sys tem. The circulating pump is started and firing begun at low heat until the Aroclor 1248 has reached a temperature of 250F. Periodically during this initial up-heating, the lines should be vented every 10-15 minutes for at least two hours to allow any residual moisture or air to escape. After it is certain that all moisture has been eliminated from the system, the entire system should be inspected for leaks with the pump circulating the hot fluid. As a final inspection, the expansion tank should be checked to make sure that the tank is % full. After this, the burner can be set to full-fire and the system brought up to operating tem perature.
When die temperature of operation has been reached all controls should be checked and adjusted so that the burner is regulated for full modulation. When the system is brought to full operating temperature, all pipe lines should be given a final inspection for expansion and bracing.
053172*
TOWOLDMON0036155 WATER_PCB-00020624
GENERAL RECOMMENDATIONS for Operation and Maintenance
The following recommendations are primarily guides for the manner of using Aroclor 1248 in an operating system. They are supplemental to the equipment manufacturer's own recommendations for operation and maintenance that relate to the heaters or the heat-using installations themselves. The recommendations for start-up, shut-down, precautions in event of power Failure, and periodic check-ups on the fluid and equip ment apply as generally accepted practice on all types and sizes of systems. By following these recommendations, the troublefree service life of the heat transfer fluid will be increased.
START-UP
When systems have been shut down for week-ends or over-night and the fluid is cooled to room temperature, follow this start-up procedure:
1. Start the circulating pump and check the expansion tank to make certain the Aroclor 1248 is at the primer cold-start level (Tank should be %-full.)
2. Start burner at minimum flame setting and continue full circulation until Aroclor 1248 is heated to 180"F. when measured on the return side of the heater.
3. Turn heater up to full heat.
SHUT-DOWN
The following procedure will eliminate overheating of the fluid when shutting down:
1. Shut off burner completely with circulating pump still oper ating. Continue to run the circulating pump at full head for at least Vi hour to dissipate high residual heat in the com bustion chamber of the burner.
2. Shut off circulating pump at the end of Vi hour and switch off all heater electrical controls.
PRECAUTIONS IN COLD WEATHER
When heat exchanger is exposed to ambient tempera tures Ixdow 50F., it is recommended that unit not be shut down. It is recommended that the burner be turned low and the fluid circulated continuously at about 200F. The unit will then be "at ready" for immediate high temperature operation.
PRECAUTIONS IN CASE OF POWER FAILURE
In case of power failure, the(bumer circuit is interrupted by the heater controls. When pow^r comes on, the circulating pump should first be run for a few minutes to eliminate any vapor pockets that might have been formed by the fluid's being held static in the hot combustion chamber. If there is no knock ing in the piping system, full-fire mky be resumed immediately,
if the fluid temperature is above 180F,
PERIODIC CHECK-UPS
i
The regular maintenance inspection schedule should
include the equipment manufacturer's recommendations and
also inspection of the heat transfer fluid. The following is a
listing of check points.
1. Lubrication of moving parts:
2. Operating fidelity and accuracy of readings of safety controls and temperature limit controls.
3. Inspection of heater tulxs; burner, refractory linings. 4. Periodic cleaning of hcalcy>riirfaces. 5. Inspection of water coolin^'at the circulating pump.
6. Regular^ repacking of stuffing boxes according to the manu facturer's recommendations!*,
7. Semi-annual or annual sampling and analysis of Aroclor 1248.
Under normal operating cdhditions not affected by fre quent power failures or accidental overheating, when Aroclor
1248 is operated at 600F. it should not be necessary to check on the condition of the fluid more often than once or twice a year.
The analysis for fluid condition is a simple determina tion of viscosity. The information given in Figure 6 serves as a guide to estimate the condition of the fluid, according to vis
cosity values. Most users do their own testing; some have the viscosity determination made by an outside laboratory.
Customers can have their fluid tested by Monsanto free of charge. A one-quart sample is required, and sample should be carefully packed to avoid breakage in shipment. .Samples should be shipped to:
Monsanto Chemical Company
Organic Chemicals Division
Industrial Fluid Sales
St. Louis, Missouri
ABOVE INFORMATION APPEARS ON POCKET CARDS INSIDE BACK COVER
0531725
22
TOWOLDMON0036156 WATER_PCB-00020625
Designing or purchasing equipment for a heating system to be operated with Aroclor as a medium to deliver heat into a process requires consideration of heat transfer characteristics of both the user and the heater. The actual heat which can be absorbed by a user, for example, depends upon the over-all heat transfer coefficient, heat transfer area, and a mean tem perature difference between Aroclor and the material being heated. Both overall heat transfer coefficient and mean temperature difference are, in turn, affected by the flow rate of the Aroclor. This inter-relation of flow rate, heat, and temperature is usually solved by a trial and error procedure as covered in standard reference texts. The approach of Granet(8) may be used to minimize or eliminate trial and error.
The following tables and graphs of physical properties and engi neering data are provided as an aid in layout and design calculations for systems to be operated with Aroclor 1248 as a heat transfer fluid in the liquid phase.
Table IV lists properties useful in heat balance calculations by which the flow rate is related to the heat transferred and the temperature change of the Aroclor. This relation is also shown graphically in Figure 10.
The over-all heat transfer coefficient for the heater or user may be estimated by the methods outlined in die texts of McAdams(4) or Kemf). This is usually done by combining the individual film coefficient of the Aroclor with other coefficients and conductivities to yield the over-all coefficient. Table V contains physical properties of Aroclor as a function of temperature which are needed for calculating the Aroclor film coefficient. Table VI gives typical film coefficients for Aroclor flowing through a 0.81 inch i.d. tube. These are listed as a function of temperature and flow rate in a tubular heat exchanger. Other tube sizes would, of course, require a correction for the diameter in the Reynolds and Nusselt group of the equation (from McAdams) given at the top of Table VI. Correlations for estimating film coefficients for various materials that might be processed by indirect heating may be found in the texts cited (4), (5) and elsewhere in the literature.
For sizing pipe lines and pumping requirements. Figure 11 shows pressure drop vs. flow rate and pipe size for Aroclor 1248 at temperatures over 300F. Above this temperature Aroclor 1248 flows freely like water.
A bibliography appears on page 32.
0531726
TOWOLDMON0036157 WATER_PCB-00020626
Temperature F. C.
32 0 4(1 4 SO 10 bo 16 /o 21 so 27 90 32 100 38 no 43 120 49 130 54 J41) SO ISO 66 160 71 1/0 77 ISO 82 wo 88 200 93 210 99 220 104 230 no 240 116 2S0 121 2bU . 127 2/0 132 2S0 138 2110 143 3ttft 149 3)0 154 J2U 160 330 166 340 171 3 SO 177 3bU 182 3/0 188 380 193 390 199 400 204 410 210 420 216 430 221 440 227 450 232 460 238 4/0 243 480 249 491) 254 SOU 260 S10 266 520 271 S3) 277 540 282 550 238 5SD 293 5/0 299 sr;i 304 59) 310 bO'J 316 blO 321 620 327 630 332
Enthalpy Btu./lb.
0.000 2.162 4.881 7.616 10.367 13.134 15.917 18.716 21.531 24.362 27.209 30.072 32.951 35.846 38.757 41.784 44.727 47.686 50.661 53.651 56.657 59.679 62.717 65.771 68.84] 71.927 74.029 77.147 80.281 83.431 86.597 89.779 92.977 96.191 99.421 102.667 105.929 109.206 112.499 115.808 119.133 122.474 125.831 129.201 132.593 135.998 139.419 142.856 146.309 149.778 153.262 156.762 160.278 163.810 167.358 170.922 174.502 178.098 181.710 185.338 188.982
Cp (Spec. Heat) Btu./lb./'F.
0.2695
0.2711 0.2727 0.2743 0.2759 0.2775 0.2791 0.2807 0.2823 0.2839 0.2855 0.2871 0.2887 0.2903 0.2919 0.2935 0.2951 0.2967 0.2982 0.2998 0.3014 0.3030 0.3046 0.3062 0.3078 0.3094 0.3110 0.3126 0.3142 0.3158 0.3174 0.3190 0.3206 0.3222 0.3238 0.3254 0.3269 0.3285 0.3301 0.3317 0.3331 0.3349 0.3365 0.3381 0.3307 0.3413 0.3429 0.3445 0.3461 0.3476 0.3492 0.3508 0.3524 0.3540 0.3556 0.357?
0.3588 0.3604 0.3620 0.3636 0.3652
Density Lbs./cu. ft.
91.6 91.3 90.9 90.6 90.2 89.8 89.5 89.1 88.8 88.4 88.1 87.8 87.4 87.0 85.6 85.2 85.9 85.6 85.2 84.8 84.4 84.1 83.7 83.4 83.1 82.9 82.6 82.3 81.9 81.6 81.2 80.9 80.6 80.2 79.8 79.4 79.1 73 8
78.5 78.2 77.9 77.6 77.2 76.8 76.4 76.1 75.7 75.4 75.0 74.7 74.4 74.1 73.7 73.4 73.0 72.7 72.4 72.0 71.7 71.4 71.0
Lbs./gal.
12.22 12.19 12.13 12.08 12.03 12.00 11.96 11.91 11.87
11.82 11.77 11.73 11.69 11.64 11.58 11.53 11.47 11.42 11.38 11.34 11.29 11.24 11.18 11.14 11.10 11.05 11.03 10.98 10.94
10.90 10.85 10.81 10.76 10.71 10.67 10.62 10.57 10.53 10.48 10.43 10.39 10.34 10.30 10.25 10.20 10.16 10.11 10.06 10.0? 9.98 9.94 9.90 9.85 9.80 9.76 5.71 9.67 9.63
9.58 9.53 9.48
Specific Gravity
1,47 1.46 1.455 1.45 1.445 1.40 1.432 1.425 1.420 1.414 1.409 1.404 1.400 1.493 1.387 1.381 1.375 1.370 1.365 1.359 1.353 1.348 1.342 1.336 1.331 1.326 1.321 1.316 1.311 1.305 1.300 1.296 1.291 1.285 1.280 1.274 1.269 1.264 1.269 1.253 1.248 1.243 1.237 1.231 1.225 1.220 1.214 1.208 1.202 1.196
1.191 1.186 1.180 1.175 1.170 1.165 1.160 1.155 1.150 1.144 1.138
Absolute Viscosity in CentipQtHt
850 380 200 115 66 47 32 24
18 14 11 9.1 7.5 6.3 5.2 4.4 3.9 3.35 3.00 2.68 2.38 2.08 1.96 1.82 1.68 1.58 1.46 J.42 1.30 1.22 J.15 MO 1.05 1.00 0.96 0.91 0.87 0.84 0.80 0.76 0.73 0.71 .068 0.65 0-61 0.60 0.57 055 0.53 0.51 0.49 0.47 0.45 0.43 0.42 0.40 0 39 0.37
0531727
i
TOWOLDMON0036158 WATER_PCB-00020627
FLOW RATES FOR AROCLOR 1248
Figure 10
Aik'.Tfar
i-j
JSUJ! `UJLISKHii!.
0531726
TOWOLDMON0036159 WATER_PCB-00020628
TABLE V
THERMODYNAMIC PROPERTIES of ABOCLOB 1248
PRANDTL
!
A&wMS c. Viscosity
ft"nr. f.
0 0.0577
4 .0576
10 0.575
10 2060
.0574
9844
21 960
.0573
4430
27 485
.0572
2353
32 278
.0570
1361
33 160
.0569
789
43 114
sm
566
49
77.5
.0566
388
54
58.0
.0565
293
60
43.5
.0564
221
66
33.8
.0563
173
71
26.6
.0562
137
77
22.0
.0560
115
32 18.2 .0559 95
88 15.2 .0558 80
93 12.6 X557 67
99 10.6 .0555 57
104
9.45 .0554
51.1
110
8.10 .0553
44.1
116
726 .0552
39.8
121
6.48 .0550
35.9
127
5.76 .0549
32.1
132
5.03 .0548
28.2
138
4.75 .0547
26.8
143
4.40 .0546
25.1
149
4.07 .0544
23.4
154
3.83 .0543
212
39.5 28.7 22.3 17.9 14.4 12.6 10.8 9.7 8.7 7.88 7.15 6.68 6.18 5.78 5.38 5.05 4.83 4.55 <36 4.18 4.00 3.81 3.73 3.63 3.53
3.45
JT.____
C-
320 160 330 166 340 171 350 177 360 182 370 188 380 193 390 199 400 204 410 210 420 216 430 221 440 227 450 232 460 238 470 243 480 249 490 254 500 260 510 266 520 271 530 277 540 282 550 288 . 560 293 ` 570 299 580 304 590 310 600 316
Thermal Coadvetivitr
Btn.
*F.~
353 .0542 3.34 ;. .0541 3.14 .0540 2.95 .0539 2.78 .0537 2.66 .0536 2.54 .0535 2.42 .0534 Ul .0532 2.20 .0531 2.10 .0530 2X13 .0529 1.93 .0527 1.83 .0526 1.76 .0525 1.71 ; .0524 1.64 .0523 1.57 .0521 1.51 .0520 1.45 .0519 1.38 .0518 1.33 .0516 1.28 .0515 122 .0514 1.18 .0513 1.13 .0512 1.09 .0510 1.04 .0509 1.01 .0508
k__
20.6 19.6 18.5 17.5 1S.7 15.1 15.4 14.8 U.3 13.7 13.1 12.7 12.3 11.7 1U 11.0 10.7 102 10.0 9.67 9.26 9.00 8.72 8.36 8.14 7.85 7.53 7.33 7.16
0.4
3iS 329 322 3.15 3.08 3.04 2.99 2.94 2.90 2.85 2.80 2.76 2.73 2.68 2.64 2.61 2.58 2.54 2.51 2.46 2.43 2.40 2.37 2.34 7.31 2.28 2.25 2.22 Z20
0531729
TOWOLDMON0036160 WATER_PCB-00020629
TABLE VI HEAT TRANSFER DATA for AROCLOR 1248
FILM COEFFICIENTS
" ~ [of]|30 8 Kl
i Based m flaw Xkn& Ml' I. 0. Me (I' 9.9.113 p) expressed to 5t./se. tt/hr./T.
FLOW RATE, CPU.
F. 1.0 2.0 3.0 4.0 5.0 6.0 150 83.2
200
44.9 - ;
63.4
78.7
94.0 109
250 33.5 58.5 80.9 102 122 141
300
40.5
70.1 .
97
122
146
169
350 45.3 79.0 109 137 164 190
400
49.0 85.5 118
149
178 *
206
450 53.3 93 128 162 193 224
500 56.3 98 136 171 204 236
550 60.5 105 145 183 219 253
600 64.2 112 155 195 233 269
7.0 86.2 124 159 191 215 232 253 267 286 305
8.0 93.8 138 177 212 239 259 282 297 319 339
9.0 103 151 195 233 262 284 309 327 350 373
10.0 114 * 164 212 254 286 309 336 356 381 405
11.0 123 179 229 274 309 334 363 383 411 437
Calcolatieas for other pipe sizes can tie made oslitf the data found In Tames IY and Y. Me (Hit weffWerrts were eafevlated for flew rates where the Reynolds eomber was less than 2100.
124 130 191 245 294 331 358 388 411 441 469
0531730
TOWOLDMON0036161 WATER_PCB-00020630
FRICTION LOSSES IN SYSTEM PIPING AROCLOR 1248, ABOVE SOOT.
, '` .
, ;
1I
A 200,000 Btu. (right) and a 300.000 Btu. heater, both gas-fired, have been in use at Monsanto for over 14 years for organic chemicals reactions. The heaters have operated near 6IXPF. with the same charge of Aroclor 1248 for periods of 7 years.
0531732
TOWOLDMON0036163 WATER_PCB-00020632
A Tatar submerged pump
An insulated Aredor return fine
A noo-intulated vent liM
An Aroclor drain port (Optional) A steam outlet from the ceil
to a steam trap with ' a bypass around the trap
(Optional) A steam inlet line leading to a steam coil
inside the reservoir for taatini cold Aroclor.
Aneltr Muter; Each heater consists of fire brick-lined walls and bottom inside a steel shell with steel baffles to force the hot combustion gases over the Aroclor coil for three passes. The top is a steel plate.
30
Outlet connection from coil witt a western thermometer looking up
Aroclor outlet from cooler Tbe Aroclor outlet from tne cooler
ties into the main line above the picture
Sight side water outlet Left side water ialat Cooler: Two-Stage shell and tube construction with the Aroclor 1248 on the outside of the tubes. The two-stage cooler is piped so that one stage can be used on each Aroclor heater or both stages can be used on either Aroclor heater.
. 0531733
TOWOLDMON0036164 WATER_PCB-00020633
RIGHT A 40,000 Btu. per hour electrically heated portable heat exchanger used to heat vesselsof about 50 gallons workingcapac ity. This unit was built for a variety of small scale chemical reactions. It was initially designed to vaporize approxi mately 200 lbs./hr. of an organic com pound which has a heat of vaporization of 150 Btu. per pound; a 30% heat loss was allowed for. Experience with the heater indicates that a horizontal rather than the vertical mounting of the immer sion heater (at operator's left) would have been more satisfactory.
FAR RIGHT A 4,000,000 Btu./hr. forced circulation International LaMont heater.
RI6NT Control panel for a 3,000,000 Btu./hr. International LaMont heater that oper ates the 3,500 gallon, glass-lined kettle shown on the left. This kettle is the largest of its kind in the United States.
FAR RIGHT Commercial heaters operating on Aroclor 1243 are available in any capacitydesired. This is a 1,200,000 Btu./hr, installation.
TOWOLDMON0036165 WATER_PCB-00020634
FAR LEFT A piled plant resin processing vessel operated on indirect heat transferred by Aroclor 1248. Vessel and heater are mounted together in one unit. LEFT This 500,000 Btu./hr. forced circulation heater is electrically heated and designed for a liquid temperature of 500F. The construction is similar to a doable pipe heat exchanger with the electric heating elements in the inner pipe; the Aroclor 1248 circulates through the annular space between inner and outer pipe. The Squid Aroclor 1248 is delivered from the heater at a temperature of 500F. and heats the contents of a jacketed kettle with a batch capacity of 1,000 gallons.
LljTERATURE CITED
1. Monsanto Chemical Co., St. Louis, Mo., Application Data Bulletui O-P-115 (1954).
2. Sullivan, M. V.,|Wolfe, J. K., and Zisman, W. A., "Indus. Eng.Chem.," 39, 1607 (1947).
Granet I., Heat Transfer Performance Curves", Chemical Engineering, P. 187-190, March, 1955.
McAdams, W. H., "Heat-Transmission", McGraw-Hill Book Co., Inc., New York, (1942).
5. Kem, D. Q., "Process Heal Transfer", McGraw-Hill Book Co., Incj., New York* (1950).
0531735
TOWOLDMON0036166 WATER_PCB-00020635
. Card No,' 2 5 tper*fen of And* 1244 but transfer Systems, ?
, ....v` * '
.:-/< ; .
a
^ GENERAL RECOMMENDATIONS FOR '
(OPERATION and MAINTENANCE
't^.mMl248: Heat transfer systems
New or overhauled systems must be TESTED FOR LEAXS and THOROUGHLY CLEANED OUT. This fan be done in one operation as follows:
Fill (tie empty system with cleaning solution (5 lbs. caustic soda and 5 lbs. of soda ash ia each 1000 lbs. or 120 gaL of water).
Thoroughly vent the system to insure complete filling. Close the vents and start the circulation pump.
During this time, periodically drain oft from a low spot some of the solution and replace this volume with clearwater. Do this until the fluid in the system is clear. This takes about 24 hours.
'Mien clear, raise the exfi fluid temperature to 215-225*F.r then him the burner and mtmp off.
Nest drain the entire system and open all vents. Residual heat will dry out the moisture. When inspection shows the system is thoroughly dry, dose all drains and vents.
. Now fill the system with Monsanto Aroclor 1248 until the expan* sion tank gauge reads 1/4 full.
Start the circulating jitinijt and !nni flm__________ ____________ Heat the fluid to 250 1. (return (cmp.) over n two-hour period. During this time, vent the lines every 10-15 minutes to allow any residual water vapor and air to escape. Itcinspcct the entire system for leaks while fluid circulates, Again inspect the expansion tank to make sure it is 1/4 full.
Finally, set lltc burner for full heat. Bring system up to normal operating temperature. Adjust all controls for full modulation. Examine nil pipelines for expansion, adequate bracing and leaks. Proceed with normal operations.
*.st*04S- troto ik u * a
(over)
The following instructions apply to all Arodor heating systems and are supplemental to manufacturers' recommendations for the equipment proper.
a system has been shut down long enough for the Aroclor to cool below 180'F.).
Start circulation numo and cheek expansion tank (should be
"l/4 full). -----------
------------ `-----------------
0Start burner on lowest heat and maintain full circulation return Huid temperature reaches 180*F.
QSet burner for full heat. Resume normal operation when fluid reaches proper temperature.
(follow these instructions to prevent localized over-heating when system is being shut down).
iHshut burner off but maintain full circulation for at least 1/2 hour to dissipate high residual heat in combustion chamber.
|^If air temperature is under 50"F., keep fluid circulating constantly at 200'F.
Power failure automatically interrupts (lie burner operation. When power resumes, start the circulation pump to get rid of any vapor pockets that may have formed in the heater tubes. If^fhtid is atffljiot (above 180*F.), full heat may be resumed
If returning fluid has cooled below 180* F. during power failure and initial circulation, follow Start-up Procedure above.
For more details, consult Monsanto's booklet on "Aroclor 1248 Heat Transfer Data", or contact