Document 91b0qaQjYXRXZGxdkg00MQYoD

PLAINTIFF'S EXHIBIT Guaranteed for 25 Years! The cast iron sections -- the working core of this boiler -- are guaranteed for 25 years in residence. Guarantee applies to water models of this boiler. See guaran tee for full responsibility assumed by American-Standard. mo G-2 gas-fired boilers AMERiCAN-^tandard U til ' ^ the G-2--new, extra-compact models for every type of installation The G-2 is a completely new, fully automatic cast iron gas boiler for water or steam heating developed by AmericanStandard for fast, economical installation, peak operating efficiency and long-lasting dependability. This extremely com pact gas boiler stands only 33V2" high -- requires minimum space, making it particularly suited for all residential installa tions where space is at a premium. Packaged water boiler for any application --Five popular sizes (3-7 sections) of the forced circulation pack aged units are shipped completely assembled and crated, ready for immediate installation. All controls, burners, ac cessories-even the circulator--are installed and wired before shipment. Three units (5-7 sections) may be equipped with a specially built, factory-installed, l=W=H rated tank less heater for forced circulation installations. These same sizes are also furnished as an all-purpose package that ex cludes the circulator to permit either forced or gravity cir culation installations. Nonpackaged water and steam boilers --available in all sizes (3-11 sections) with flush or deluxe jacket as forced circulation water boiler or all-purpose steam or water (forced or gravity) boiler. Nonpackaged boilers feature factory-assembled sections, preassembled manifold and pre assembled gas controls. (Factory-installed l=W=H rated tankless heater available for forced circulation water boiler only.) Top-rated domestic hot water --High domestic hot water ratings (l=W=H approved) are one of the major features of the G-2. These outstanding ratings are realized through the use of a specially designed built-in tankless heater develooed exclusively for, and tested with, the G-2. Units are available, beginning with the 5-section boiler, with a large-coil heater factory installed (optional). Simplified piping and control arrangement --Con venient location of all controls, piping, accessories and cir culator on the left and front of the boiler means fast, lowcost wiring and piping hook-ups. This arrangement speeds up installation time, simplifies adjustments and reduces over-all labor and expense on every job. Packaged models of the G-2 have all components pre-assembled and mounted for immediate connection. Highly efficient sections and burners--A combination of newly designed cast iron sections, plus integral one-piece burners, makes the G-2 an extremely compact boiler with a high heating output. Pin-type surfaces of the sections and the high, off-center location of the 5" nipple port assure rapid heat transfer, peak circulation for quick pick-up. Another plus feature of the G-2 is the spacing of one burner to each flueway for maximum heating efficiency. New jacket design for installation flexibility-- Another outstanding advantage of the G-2 is its "off-the-floor" jacket design (jacket rides 1" off the floor). This prevents damage in shipment, helps prevent rust and corrosion and allows boilers to be "walked" into position with the jacket in place.--Additional installation flexibility is achieved through the compactness of the G-2, plus an A.G.A. approved special floor shield fdr combustible flooring (regularly fur nished with packaged models, optional for non-packaged models). Also, extra-low height and "zero" clearance ap proval for deluxe jacket models make the G-2 especially suited for installation in utility rooms and almost any con venient location. ^ note these important new design features B I - W " H rored, high-<apacity (anklets water heater - designed exclusively for G-2 forced circulation boilers--fits into the large, off-center, over-sized 5" nipple port at the top of the boiler sections The unusual location of the nipple port creates a continuous pumping action that accentuates the boiler water circu lation around the coil -- surrounds the heater with the hottest water. The large-coil tankless heater consists of variable lengths of loosely wound finned tubing designed for maximum heat extraction from the boiler water. It is available in 3 sizes and factory installed in boilers beginning with the 5-section size. I = W = H approved ratings are obtained by testing the heaters with each size G-2 boiler. M Research-engineered cast iron sections -- combine a large heating surface with a 5" nipple port for maximum heating efficiency with the G-2. Each section contains scientific ally placed, pin-type projections for the great est possible heat extraction from hot flue gases. Top location of the nipple port also provides the best circulation --assures rapid boiler water recovery. The new section design permits placement of one burner to each flue way. This arrangement means high concentra tion of heating gases --rapid heat transfer to boiler water. Basic assembly of the G-2 re quires only a left-hand end, right-hand end and center sections. Sections are cleaned from the front of the boiler. B Complete factory-installed manifold and wiring - saves installation time and costs on all packaged models of the G-2. Newly de signed one-piece burner-mixing tube is pre cision fitted into manifold spud and rests securely on the rear boiler base plate. Simple regulation of the air shutter is the onljr adjustment required for correct firing. All nonpackaged boilers have the complete manifold assembly shipped separately as illustrated. Both drilled port and ribbon type burners are available with the G-2 for highly efficient, economical burning of all gases. Provision is also made for optional dual fuel equipment, runner type and push button electric ignitions with all sizes and models of the G-2. ^ G-2 gas boilers by American-Standard have ratings approved by the Institute of Boiler and Radiator Manufacturers and are constructed to the specifications of the American Society of Mechanical Engineers. The boilers are approved by the American Gas Association for all gases and for high altitude installations. They also have the approval of the A. G. A. for installation on combustible flooring with a special floor shield and for "zero" clearance installation with deluxe jacket models. All sizes of the G-2 are available in models for forced hot water, gravity and steam systems. 1 --controls--(water boiler illustrated) all controls (including new control that combines operating, high limit and low voltage relay into one control) mounted on front and left side of boiler for easy ad|u$tment and maintenance. Controls, accessor ies, manifold and circulator factory mounted and assembled on all packaged forced circulation boilers. (Not illustrated -- steam boiler controls include external low water cut-off, water gauge glass, steam safety valve, steam limit controls.) 2 - tappings - 2" supply (top) and 1 Vi" return tappings (side) simplify piping hook-up, reduce bushing expense and labor. 3- water heater-large, copper coil, finned tubing tankless type with outstanding l=W=H ratings. Exclusive with the G-2. (See design features.) 4- built-in drafthood-completely enclosed in deluxe jacket models - keeps boiler height at an extra-low 33Vi". External type drafthood fur nished on all flush jacket models. 5- jacket--sturdy 20-gauge steel with new warm gray finish, modern radius corners. Inner surfaces finished with corrosion-resistant, heat-reflecting aluminum paint. Shipped factory installed with all packaged boilers. 4-insulation-heavy fiberglass insulation pre vents wasteful heat loss, keeps jacket cool. 7 -- burners -- precision-engineered, one-piece cast iron drilled port (or ribbon type) factory tested for quiet, efficient operation. Air shutter and mixing tube integrated into single-piece burner. S -- boiler sections-constructed of rugged cast iron; multiple pin-type projections stud flue sur faces for maximum heat extraction. End sections have extended base design - form supporting legs of boiler. All sections may be cleaned from the front by removing cleanout plate (not shown) bolted to boiler sections. ?-gas pressure regulator - maintains uniform gas pressure to all main burners. Regulator not required for LP gas. 10 --manifold controls -- including automatic gas valve, pilot filter and 100% safety shutoff for all gases are completely factory assembled and in stalled in all packaged boilers. Manifold rigidly attached to boiler with heavy sfeel brackets. Com pletely enclosed by jacket on deluxe models. ^ the G-2 packaged boiler for fast, low-cost installation Packaged models of the G-2 are factory assembled complete with wiring, accessories, controls, cir culator and mam burners already mounted for quick, economical installation. Entire boiler as sembly is shipped completely crated-boiler is kept clean dur ing shipment by protective,poly ethylene cover. Highly compact construction of the G-2 permits boiler to be moved into position for final hook-up quickly and easily. Sus pended jacket design allows boiler to be "walked" from crate to installation without pipe roll ers. Complete installation, from crate to connections, takes less than an hour. G-2 ratings (all gases) fo installations from sea level to 2000 ft < -- chimney boiler number G-23 G-24 G-25 G-26 G-27 G-28 G-29 G-210 G-211 A. S. A. input Btuh 60,000 90,000 120,000 150,000 180,000 210,000 240,000 270,000 300,000 A. G. A. output Btuh 48,000 72,000 96,000 120,000 144,000 168,000 192,000 216,000 240,000 net i == B = R ratings steam Mbh steam sq. It. 36 150 54 225 72 300 90 375 108 450 126 525 144 600 162 675 180 750 ___________ water Mbh 36 54 72 90 108 126 144 162 180 inches 4 5 6 6 6 7 7 7 7 height feet 20 20 20 20 20 20 20 20 20 4 For altitudes above 2000 ft., ratings should be reduced at the rate of 4% for each 1000 ft. above sea level. Note: Suffixes used with G*2 boilers denote the following: F-ffush jacket; 0-de!uxe jacket; T-with tankless heater; P-packaged ship- ment; C- with floor shield approved for combustible flooring. For example--to order a deluxe G-25 complete with heater, combustible flooring shield and completely packaged - the following boiler designation would apply {G-25-DPTC). built-in tankless heaters1 heater number 222 222 222 222 222 222 222 l =w = H rating a 3 3-1/4 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 ' boiler number G-25 G-26 G-27 G-28 G-29 G-210 G-211 A. G. A. input Mbh 120 150 180 210 240 270 300 heater number 226 226 226 226 226 232 232 232 l =W=H rating a 4 4-1/4 4-1/4 4-1/4 4-1/2 4-1/2 4-3/4 5 boiler number G-27 G-28 G-29 G-210 G-211 G-29 G-210 G-211 A. G. A. input Mbh 180 210 240 270 300 240 270 300 1 ] 0 Heaters have been tested with G-2 boilers and are available only factory installed in all models in the above sizes except for the all purpose boiJers. Last two digits designate lineal feet of Tru Fm tubing in heater coil A Gallons water per minute heated from 4Q*F td 140*F wr th 2003F boiler water temperature. control applications location tappings on size boiler -- inches A ya B% C y* D y E y< F 3- water immersion limit control temperature and altitude gauge reverse acting control pressure relief valve combination operating, high limit and low voltage relay immersion control gravity flow steam pressure gauge safety valve blow-off side view showing taopmgs fw forced circulation _ front view assembly showing tapping for forced circulation and all-purpose Every all-purpose nonpackaged boiler is shipped with tappings for both hot water and steam. side view showing lappings for all-purpose American-Standard G-2 Gas-Fired Boilers are another development in hydronics --the science of heating and cooling with water. 1 AMERiCAN-c^tandard plumbing and heating division AMERICAN RADIATOR & STANDARD SANITARY CORPORATION AO WEST AOTH STREET . NEW YORK 18, NEW YORK I... l_/iho '8 U 5 A