Document 91Mvn3XMD4OpgrYvVkLJNnGZ3
flw; d ~C
_>*ji awe rr (uuuu v.-c-e-w n * w . w i t^corda of Che N. C. Dept . of Labor
C * , * ? *
\J
**
*
t; so/ih Mo.
2. OSHA 1 No.
N. C. DEPARTMENT OF LABOR /
oma or occt^ATioiou. u/rn aw hcmtx '
1-
4 m f aMiM In.
,
km*k. a. C. ten
'Xs\y
` : CITATION
.<] : :H ~
J-. ' . ' a u. y
3. TO:
Fiber Industries, Inc.
/JK
\ 4... A *Z '
Post Office Box 10038 Charlotte, North Carolina ,28237.
t
)1 ..TYPE OF ALLEGED VIOLATION(S): Non-eerious
K-2992________ 112-78
4. CiutitxTNumbcr
0P3..
5. P*g
ol 6.
;*
r v 7. An intpaction ww mad* on )Urch 7, 9 8Cd 9|
19 7& of , piKt ol imploymmt locitad it:
1
I. '1300 Archdale Drive, Charlotte. Worth CiroHm________________________
' and dcfibd n follow,:
B. OrjpiHp ffhtre______________ ,____________________________________________----------------------------------- I------- :----- -------------
vr
turn
No.
0* in bea* of tM infection t n aiteoad that you r in the foyo*rng i(tOetl
SundiriJ. regulation or section of the Act * eHegedly violated
1 violated the North Caroline Oecueeiionei SeUiy end Health Act o> 1973,
Description of alleged violation
TT----Oate by which alleged violation
mutt be corrected.
29 era 1910.2J^2(b) Failure to reduce air pressure used for cleaning Ns purposes In first floor machine shop and fourth floor chip drying area to less than 30 p.s.i.'
May 15, 1978
; 2 29 CFR 1910.212(a) Failure to guard ingoing nip points on plying
(1) machine on first floor.
May 15, 1978
t) i. ` i`~
* .<' .' i .
):
sV
,"'V
CvJ
-
:-V '
'p
l
Th law roqulroa that copy of tfilt elution, ihill ba prominently poatad In a contplcuout plica it or naar aicl% plica thit
. n illapad violation rtfarrad to In ttia cltillon occurrad. Tha Citation mutt rtmaln pottad until ill illipad violation! clt.d thiriln ira
' oorractad, pr lor 3 working diyi*. whichever partod It longer."!
-I
'J/'/:*/' '. A'' * , *t: . .' ' .
* "'
mown op i* *
?; H * A*y awiptoyea or topra--Miiho of employ w ho bdWwoe Ihet my podod of time Heed In ihto titoli--t ter the oocroeboh of ivtoUttoo It uhrocaonabk h-- the rtght to ^
i-4.
w I ivied ftucA time tor oorroclton by * node* with Che N. C. Dteednwnt of Ubor t< tho eddraea ibovo wltftn 11 'yorttog
of pupotvi penny or nodoe that m oeneity li twlng prooowd.
'*.
reoetol by the employer of poltoe
*HoT^toyeo h* * tftoefwr^od Of
tocawa euch empfoyoe hu Rtod any oomptotol Of ImmtMd Of 04U**d 10 ba Inanunvd any p*oodlng ot
hTQTrlan lydiro'fdtvftaiNt AotorKa* Watiflad o* I* about 16tealify In aucA prooMdlng of baoeoaeof ttwa*feUby aohenf>IO,|r**onb*natlofhlm**Kor otbac*
' of wry rto^t
by inn Act* 8m l(b| of lh NMtn C*^nrbcewononal $My mn4 Hoaim Ad of 1871
|/ii`.'*Undar Ocotctkymi Aotofy vtoHoahh Act, the topm*VfoftU>g 0ty~irwana Uondeyv through Friday* but doe* not inctoba Saturday*. Sunder*, or Stale Monday*
Tnhine.:
.......................................
; March 28. ..73
CC
ICl T:-
/
- /?'* ' J
l-
N. C. DEPARTMENT OF LABOR
'._ '
dtvmion or occupatiomA. Armr amo health . a wcrr cokhton rreirr
AALXIAH. H. C. 17*01 *
OTATTON AND PROPOSED RNA1 ORDER
TO;
{__
Fiber Industries, Inc. . P.-0. Box 4 SaTrsbury, North Carolina -/2814-4.
II * * I.
. I . .
.i
.I . I . I;
TYPE OF AUEGED VlCXATJON(S)i Non-Serlous
An Impaction wai made on . July 6, US Uwv. 70 West. Salisbury. KC Manufacturer of polyester
. - > l
SO/IH N<^ .
OSHA-l No.
C-7490
002-83
Hu oanci ini ohit
In Response Pleat*' Refer `lo OSHA
File Nn- 23,572 .
Citation Number One
'./ P*g ,
o'2_L -.f
19 82 . of place of employment local. '___ end described a> folio
On fN bd 4 fK* fraction M la afWynd JfW you twva sHoUnd th* Oacuptftwttl Wtoy and HaahK A<1 */ HottH Careiln* In lh* follewInQ ratp^ct^
tram No.-
Standard, regulation or colon of the Act
allegedly violated
Description of alleged violation
Dale by which
alleged violation mutt be corrected
29 CFR 1910.212(a) (1)
\
29 CFR 1910.307(b)
; t, > (' --v;
One o\ more methods of machine guarding were not provided to protect the operator and other employee(s) In the machine area from hazards such as those created by point of operation, Ingoing, nip points, rotating .parts, flying chips and sparks:
Aug. 25, 1982
unused portion of revolving blade on hori zontal bandsaw blade in central shop.
f ..
Equipment, wiring methods, and Installations of equipment In classified locations were not Intrinsically safe, .approved for the hazardous .(classified) location, or safe for the hazard ous (classified) location:
Sept; 15, 1902
.'fluorescent light fixtures not approved -for Class II hazardous location or pro-
. vlded with enclosures-to minimize the /.-.^deposit of-dust on lamps and to prevent
. the escape of sparks, burning material or. hot material or hot metal, in the CP area
1 * . `T - ; V* ; ~ V*
rr a o t-
The lew require; that a copy of till* citation lhall be prominently polled In a complcuoui place at or near each place that
an alleged violation referred lo In the citation occurred. The citation muil remain potted until all alleged viofalloni died
herein are corrected, or for 3 working days*, whichever period U longer.......................................`_________________
'; .7 Vv
.\
* of iMKoms
Any amplaya* or r*praa*niiltv* el ampler**! rha batlavei that any parted *f ibn* find In'thli durian ^r th* aarrtatlan .el a vtalaKen l> *nr*a.arvibla
h.i th* it*M t, tontiit iwh tlma |*r cerrafllan.by ttftng *` petlr* with th ft. C. Dapamnant at labr at ih* ad^ab* ab*v* wtihln fl working d.yt at
Iha nolpt by Iha ampleyaf. *f nedaa.ef prapaaad.paiwhy arMIta that m penalty It hair* prapaaad. ;
I
-. "Wa amplayw ihall b* dtathargad ar.dUolmbuWd agklnd beeauM awh emptayaa hat Wad iby lan.plrlnt.ar InrtlMad er aautad t* b* iMfltvHd lfry pr*
' ^ l(Mp*cilM vodt* aMviiiid U lW Art if ^l Niltfl4 *r U iWh HrttVfniyth prMndlrq >ir b*uuti *f lh oarffH by iuh
m
bahrtt *t hJrarall er arhata at any light alfardad by ihl Art* laa O. I, ff-IXtlf hfha'iOecvparfml (alary and Haalrh Art at Narth Cr/altna.
* '
,' | *m % * aa^ U/JV * ^
#UnJ# Occupil*A! Ifry ind
Kct, |K# How "Wofklog Ofy* 104 Mto&y/iK/msqK
bwi de Ml IimIimH
ladodty*. # l*u
,, ji
An Impaction wd mada on
August 22-25, A September 11,
__ 20-22 A 27-29, 10
Highway 70 West, Salisbury. Worth Carolina;
' Manufacturer of polyester
70 ol a plact ul mploymtnt locatad at: and dfcnt>#d at follow* :
On tn
> in in*0*<iin it n *il*^*d tft*i ym hv voUt*d ih* North C'o4m Occw<Mtton< bUiy rxJ Hur* Act ol 19 M.
rn th foHovwni rtipcir
- Itam No.
Standard, rsgulllion or loction ol tht Act
allodly vioUtad
Daicriptlon ol alliTod violation
Data by which *. aM9d violation
muH ba corractad
Citation Number One, issued October 3it 17fdi la amended as set forth below.
IJA 29 CFR 1910.95
S Objecting employees In drawing frame plat form in "J" building to souivl levels exceoding those listed In Tablo G-16 and falluro to lmplasont all feasible engineering and ad.ilniatrative controls.
A progress report should be sutmlttod on or before July 30, I960.
Sept. 30, 19U0 1 1
s'
A'-'
C-l
o
r-
This Amended Citation shall be . posted beside the original Citation and must remain posted until the violations cited therein have been corrected.
The law require* lhal copy ollMe citation (hall b prominently posted In s conspicuous place ar or near each placa that arvllleged violation referred lo In the cllallon occurred. The oltatlon mud remain polled unlit alt alleged violations cited therein are corrected, or tor 5 working day*1, whichever period It longer.
I
' I
I
1
Mown oe nevonn
Asty oe toptoo--Ulho o* W"P*oy*** who b*Tk*r** ihol *ny pwtod ot />**d to to* tiuiton he >* oeirotuo*o* a e*nUlw>* * u<w*MAMii >** ngiii to
Ocnt**< iwelt ivno tot corrwitan by Mltog note* with 9h N. C. 0*#*rt*w*< ol UO H th* *oopm %--rt *iiNo 11
My* ** o****i *J,N* ***>**** * **
ol ptooo--4
or nottoo tftol no y*n**ry *
yroporod
*Ho 9/eoior-- INI 04 dtooh*/?** or d*crimlAtod
Nmux *u*r\ >ytrr rvt fi*d *nr twwpU** ** to*Hh.tod ot mwN i* b* miUtuWJ *y c*cw.oing or
t/v*fw(Uon undor or rwllod lo Aol O' *m U4hod or H about lo tony to meoH
ot b04w* ol lh ** by *** wnpioyo* on WhoK olhim**il or Whwv
or mi n*nr ailoreae e, KIM Act' tea l(A| d lha here, CaroUna Oeeupaoeul IlIvtT me hmiui Aat el IIrJ
'linear lha Oeavpatienal taMr are Heir Aat the let*'VfsitiA* Oeymeana Monday, lhru(, Me ays da Joea net lnaM4a 1,kjray. tordeyi. er lM,a Woaeayt.
p---`y--
' --'
Donald Q. Wiseman
laemnea Paw,
7t
. H.-fiQ.
01ICM
a i viymuf iyauxa>Sr(//7/
<3//>y r
-/
N. C. DEPARTMENT OF LABOR
OfPICE Of OCCUPATIONAL SAfETV AND HEALTH
4 WmI CdxlWl 11/Ml
P.MjK, N. C. T7M1
CITATION
A.Tu'.niiD
3. TO:
Fiber Industries, Inc. ' Post Office fbx /
Salisbury, Worth Carolinn
2filIJ,
\
"\ 1. SO/IH.^J/. I
r-:.C:.c
2. OSHA-1 No. C09-79
4. Qtatlon Number
Ore '
S. Page
ol8. ____ 2_
iiM iM trim i.iih
TYPE OF ALLEGED VIOLATION(S): Horv-ScrioUS
August 22-25 & September 11, 12,
I 7. An impection v*a mad* on /'l>-22 P.p/t
_____________________-19 2JL
23,572
ol plac* of employment located at:
8. - lli^r.rjv 7n'.li-st. .'hll:Lm-/. Hc-rtli CunUnn_______________ ________________ and described a, follows :
9. H-i-jiI'i'/-I.-i'v.- nf [('iTiii.cr;
ur
tom
No.
On Ihe bem of tn. tntpeclion ll 11 ellev.il met you have vtolalM, the Nonh Carolina Oecuoational Sal.ty and H.elin Ael ol 1973, In ih# following fmcu-
rr Standard. regulation or taction of tho Act llogadty viototnd
TT
Description of alleged violation 1 s
Ooto by which alloyed violation
mult be corrected
u 29 cm 1910.95
"Ainondcil Vor Consent Order, OULUXJ Ko.
A. Subjecting employees in pad: strip;,In;; in G October Jl,
'builtllnn Orel clrawinc flume plitfor-j in J
-1779
Luiltiin," to tiourel luvuln uy.cccdlni; those
, liutcU'in Table C-16 arei failure to impli.-ucttl
, all feasible cncineor.in^ aikj^bmLniutraLiVii
controls.
A iiroiTciia roport tsmt/W filed tilth this office on or before July 31//17/9-
.1
' . . ' '1 '
..
,L
\'
vvl
to
; C\f
; o
X \,
3
f. .
; -X:-
ict^pli
Tho law requires lhf a copy ol Ihla citation ihall b promlnanlly posted In 1 conspicuous pises st or nssr oechVtece that an alleged violation referred to In the cltetlon occurred. The citation must remain poaled until all alleged violations cltad-lhereln are corrected,-or lor 3 working days', whichever period la longer.
HIOKTS OP IUPL0V1SS
.
...
Any omployee or repraeonuttve of employ*** who bollevo* thit any period ol Ume flted In thla citation lor tho correction of o violation la unreasonable hae tho right ct>
eOTtaet ouch Ume for corrocllon by Wing o nolle* with tho N. C. Department of Libor it tho Iddroit above within IA working diyt of tho receipt by tho omployor ofnotice
of propoted penalty or notice that no penalty la being propoeed.
*No employee iholi bo dlacherged or dhertmlneled ogilnat bocouM tueh omployoo hn tiled ony complaint or Inolltulod or oouood to bo IntllMod my procoodlng or *
Intpociion undor or related to tNe Act or n*< leattiled or lo about to toatlty In aueh procoodlng or booouoo ol tho itorcloo by such employee on bohalf ol hlmaolf or others
of any right afforded by thit Act." fl*e 4(h) of tho Nonh Coroflno Occupotlonol Safety and H*oWl Act* Ol 1973.
** - ' 'H fi `
'!
'
Under tho Occupational Befe* tftd Hoolth A-ct.mtijejerkm "W:iorking Da/" miens Monday* IhroimV/rldayt but do..o.a...n.o.;t-Inc-iudo?Sat;ur/day*. Sunday *. or StatoH,,olldowya.
t
{
\
CITATION
N. C. DEPARTMENT OF LABOR
Office Of OCCUfATIOMaC lAf ITT AMO HEALTH 1 4 W#t CiMiM Street K C. 17101
AM.TIULD .
3. TO:
Fiber Iiu.'iitrio!, Inc. Post CXTIcg Iua .\ .Sallstui-/, north Carolin
2CW,
I. SO/IH Nu.
2. OSHA-1 No. u%=T)
4. Citation Numbir
CllO
S. Pjg
ol 6.
TYPE OF ALLEGED VIOLATION(S): Ilotvoorioiio
AutJi^L '.`.Z-'.'.j & Cuptixibor II, 12,
7. An impaction wn made on ___*.l*-*-J ' 11 -
t
8 ilir)r-'uy VC1 i.u:.L, JuJlulu;-/, liort.i Carolina
0 Mjmfacturor of i-olyuntur___________________
ID
O'l \ rJ>{~
o( a plica ol amployniant located at : _______________ L and daicribad at lollowi :
Item
No.
On the bm of lh inspection m it Hev*<J that you h*s violated the Noah Caroline Occupational Stiy *nd Health Aci of 19/3. In th* following rsipecii
rr Standard, regulation or taction of the Act
allegedly violated
Description of alleged violation
Data by wlucli alleged yioIjI<om
niuit be corrected
/-
tnc AOfrrt aiATWN NUMBER. ISSUED
'-V1- . ,3
AAfOlOCD ay SET FORTH 1ELOW. THIS CITATION IS A0:rrOE0 TO EXTEN0 THE ABATEMENT OATE ONLY.
J-llat I'j l',
iVi-C'
LCU..U : I, .
iM M g M a B B a s a ^ ^
702451)
Tha law requlrai (bat a copy ol Ihli citation shall bs prominently potted In a cbniplcuflui piece at or noar each place that an alleged violation relerrod to In the citation occurred. The citation mutt remain potted until ill alleged violation! cited therein are corrected, or tor 3 working dtyt\ whichever period It longtr.
RIOHTt Of lUPEOYIlt
Any employe* or representative of employee* who behaves trial any period of ttma Mi ad In this oilailon for 17m correction of a violation Itumssionablehetthe right to
cuniiat such lima for correction by filing a nolle* with the N. C. Department of Labor al tha address above within \ 5 working day* of the racalpl by tha employ a# of nultc#
of proposed penalty or nolle* that no penally la being proposed.
*No employe* ihad be diacherged or ducrtmlnelad against beeaus# ludh ampfoyae hai filed any eomplalnl or Instituted or caused to be Instituted any proceeding or
Inspection under or related to IhltAcI or has lastlflador la abnul to testify In such proceeding or because of the ***ro>* by such employe* on behalf yl hum sir or otheis
AJbfof any rtgN afforded by this Act.* See Sih) of trie North Carolina Occupational Safety and Health 61 19/3. *
/ *I .
. 'Under the Occupational Safafy and health Act, the larnyV/arklng OaySnaana Mondays through Friday* Dul doea not include Saturdays. Sunday*, or State ttoiiday*
To IT.Li 14. Olrsetor's Signature.
'-T la.uanaaO.W--
---------------------7l
"7""--
CITATION
N. C. DEPARTMENT OF LABOR
oma Of OCCUPATIONAL MITT ANO HCALTH 4 Wm Cdenton Urwl Safetf*. M. C. J7M1
i 3. TO.
Fiber Ir.-iijt.ric 3, Inc. Pert Office 13a:: fciicb-irv, llcrth Carolina
C
23112.
I. SU/IH No. :-i,-c2c.
2. OSHA-l No.
C-CV-79
V fV.i 4. Citation Number --------- i-iri--
5. Page
i of 6.
TYPE OF ALLEGED VI0LATk3n(S) : llcrv-CcricuS August 23-2$ September II, 131,
7. An imoection wu made on 3r~T3 ~r-: 77--fo, \
19
8. Vil ' *-, '~'l< I--, `iV't.1- CnTnl Tr.-___________
9. cf -clv-.t-tr______________________________
23,572 .
of a place of employment located at: '____________ and described as follows:
nT
Item No.
On th basil ol lh intoaetton it is jllayad shat you hv. violated lha North Carolina Occupational Sataty and Haalth Act ol 1973, in (ha following rao*<tt:
Standard, regulation or section ol the Act
allegedly violated
rr
Description of alleged violation
Date by whicn _ alleged violation must be corrected
THE ABOVE CITATION NUMBER. ISSUED.IS AMENDED AS SCT FORTH BELOW. THIS CITATION IS AMENOEO TO EXTENO THE ABATEMENT DATE ONLY.
L
./
iUJUlt 15, I'A a
J.sixiuiy I960
prajTnici report au..t to LI-1 -ith Litic oific'. or. or before October 15, 1`7/V ccr.euiiiin^ the -tatii of your fibotment effortu.
V
/
\
*> Vo
The law require* that a cop/ of thlr citation shall be prominently posted In a conspicuous place al or near each place that an alleged violation referred to In the citation occurred. The citation must remain posted until all alleged violations cited theroln are corrected, or for 3 wording days", whichever period Is longer.
R10HTS OF IMFLOma
A,
`
Any ampipyee or rapraaanlatlve ol employeaa whtfballevtt that any period of time llaad In thla citation for lha corractlon ol a violation Uunraaaonabla hatlharlQhl to
contact auc* time lor compaction by filing a nolle* wjih theN. C. Department of Laboranheaddrttaabovawlffi|n ISworblngdaytollfteraceiplby the employer ol notice
ol propoeed penalty or notlca that no penalty la being propoted.
*No employee mail ba ditcharged or dUetlmlnatad agalnii becauae tuch employe* hat tltad any complaint or tnatituiedor cauaed to ba Inatltutad any proceeding or
Inspection undar or raUtad to tfUa Actor bat teaUfted or la about to laailly in tuch proceedingorbecauteofifieeaerdteby tuch amployaeonbahallolhlmtailorothart
ol any right afforded by thla Ad,* See 3(h| ol the North Carolina Occupational Safety and Meaim Act ollb?J.
J*
. .
'** ' /
*Unuer the Occupational Salaty and Health Act. lha
Oay* meant Mondaya^roogh friday* but doat not Inttvde Saturday*. Sundayt, or State Holiday*.
]*, 0*r*Oo/i Signature .
. luuanoe Data.
m
\
Donald G. USrttfmav'!
-.1
N. c. department op labor
oP'tCC or occupational iArrry anq mcaltn P. O. *Ot f 7407 - NAktlOM. M. C. 17M
CITATION
3. TO:
Fiber I.-ri-uslrisaJ Ir.c. rest C'ffico Sox h GalistarsTi Ibr-h Carolina
221/(4
I. SO.
4a.
J OSHA-1 No.
CC-7-79
3. P*g__i-
ol 6. 1
TYPE OP ALLEGED VIOLATION(S):
Ifen-SOriOUO
.'.u^uat 22-25, ani September 11,
7. An Impaction wa, made on 1'
:-i,A| "7-?of
10 'r ' ol a placa of employment located at:
8. ;li
L. r -w. r.-imli",1!
9. V --..!,
.r pi w.
---------------------- -----------------------------------------------------------------------j-----
____________________ and described ai follow,: ;
On th# bad* th* Inauction ll l alleged that you hav* violated lh* Norlh Carolina O*vp*llon*l SaUty
Health A*t of tt7J. In lh# feilowlng t*P*<i>:
Standard, or MCHon of IHa A*t
allegedly violated
-t;;; 1712.V5
(hwlplion ol all*g*d violation
THE ABOVE CITATION NUMBER, ISSUCO. {s,,'vj___ , W AMCNOEO AS SET rottril BELOW. THIS ClfATlON IS AMENOED TO EXIEflO THE ASyEMENT DATE ONLY.
Oefe by which alleged* violation mvil ba corrected
f ...c -I
>A. .Iwt IV> | J. t>,
njT/jHu rvu.t l l'U.l-1 with ihir. c :T; :o,
Ui.i auitouaiiL j.'jrixj.I, cni or
U.o
folloMiny ilatca:
J.muav;' 'O, 19-'-'L
Jiaw 1, I'J.U
4.
702449
. , ... 7 ' , r '
1 his Amended Citation shall-be j, posted beside the original Citation ;i and must .remain posted until the
.violations cited therein hpve been corrected;
Th* law requires Ihal a copy of this citation thall b* promlnantly pot*d In a complcuoui placa at or naar each place ihei
an alleged violation raferrad to In th* citation occurred. Th# citation muii remain poitad until all alleged violations cited
therein are corrected, or for 3 working days*, whichever period li longer.
' ________
. IIOH Tl t Of IMN0TII1
Any employ** or r*pr*Mnl*tlv* of employ*** who b*ll*ve* that *ny period at Hm* flatd In thU citation lor h* correction ot * violation I* \,ne*ion*bl h*t lK right f# <*niatl i/<h llm* tor correction by filing nolle* with lh* N. C. Department of labor at th* *d<han ahown abov* within 13 working day* of tha
receipt by tho *mploy*r of node* of propot*d jaeneliy or nolle# that no penalty It b*lng prepoted. TNo employ** ihell b dliehargad or d^KflmlnaUd egcfrll WtwM wch employ** he* filed any complain* ** IhatHvltd or Cauied to be Inttlivted any pro
ceeding or Inspection under or ral**d lo lhl Act or hal l*tlfl*d or U abov* to t*Hlfy In lv<h proceeding or becave* of th* a*clw by %v<h employ** on b*half of hlmeelf or other* of *ny fight afforded by thl* Act.** So* SOt) of th* North Carofln* Occupational Safety end Kaalth Act of 1*73.
*U<^*r tho Occupational Safety end H**t>h Aft, lh* ktm `Working DyM piacnc Monday! through Fridayi bvt doat not Include l*t*rayt. Sunday*. or tii
Holiday*. ;* -V*V / \ a--'
la. (Erector's Ugnatvro
. hfiOL
... .lUl'.TTill
U
n-
Iiiv.m* D.i.
- r*1---!.-.-- "* 1
CITATION
N. C. DEPARTMENT OF LABOR
OfTKt Of OCCUPATIONAL U/ffTY AM) HtAiTH
i WK
t*M4
fUNVS C. IT<H
AMENDED
3. TO: Fiber Industries, Incorporated' Post Office Box 4
'dalisbuxy, North Carolina 23144
t. sc ;d. T-4628
7. OSH A t No. 009-79
4. Citation Numbtr
One
5. Pig*
ot 8.
2
70245
TYPE OF ALLEGED VIOLATION(S): Non-Serious August 22-25 and September 11, 12,
7. An Impaction wti .ntdt on . 20r.R2 flQij 2]-2<j ,19 78 8. Highway 70 West, 'Salisbury, North Carolina ___________ .
9. Manufacturer of polyester_____________________ ;J____________
of plftci of mploymtnt loctlod at:'
- and dicnbd follow*:
On th Cmiii of try me<i(on It I* In the toiiowirtf reapvcti:
that row hw vtoUtod th North CoMn Occupational Salaiy and Health Act of 1973.
Iff--------- Tr "
Stindird. rtfulltlon
turn Of taction of Act
. No.
llagadly vloUttd *
ir " ~
-------------------------------------------------------------------- in |
Dm by whieft
Ottcilpllon ot lllaged violation
Hagai) violation
mull bt corrected
/ 29 cfr 1910.151(c) ."Repeated"
16 29 CFR 1910.106(e)
(2)(ii)(b)
-
*A
, ' /'
A '
\ .
Citation Number One, issued October 31, 1978, i:
amended as eat forth below. This citation is
i,
amended to extend the abatement date only.
(A) Failure to provide suitable facilities for quick~Urenchlng`of tho eyes end body for employees that handle caustic end catalyroi . sodium sulfite in chemical storage and weighing room of T building, o-chloropheno at OOP storage area on third floor of 0 building, end cauetic at'open surface quench tanks at salt bsth/pack stripping
. area of 0 building.
(B). Failure to provide suitable facilities for quick drenching of ths eyes for employees
t that handle sulfuric, aci^ and corrosives in testing laboratory of T building.
Harch 30, 1979
Failure to limit the quantity of flammable liquids (isopropanol anhydrous and msthanol in stores area on east side of main plant and ' . chlollna base located outside additive prepare-' tion room of 0 building) outside of an inside storage roam, cabinet, or in any one fire area to 120 gallons of Class IB liquids.
Juno 30, 1979
"N
O
Th law iVquIrei that a copy ol thla citation shall b* prominently potlad In a complcuoua pl'aca 11 or naar aach placa lhal
an allagad violation referred lo In tha citation oceurrad. Tha citation muat ramaln poatad until all alltgad violation! cltad tharaln ara
corractad. or lor 3 working day**, whiohavaf partod la longar.
1* ol
' piomt oe twnoYtu ;
V
Any amployM or replaMAUIIvc at employ**. h* ball**** Vial any pwlo* *( ttmt tlao* In IN! alutlon Kir th* correction ol ytounon la untaiaonaOlo na lh rtj't lo
eontaal ruen lima lor oerraoalen by Nina a none* wim MkO. Oapsrirnanl *< Ukar il IN aMraaa abo** alIMn 11 aorkin* Oayr ol na r*o*ipt by th* amployar el nonet,
ol pcopo**c panliry or nolle* lhal no p*n*y la boWi} to^oat<.
.
*
"No vmplOY** aha! ba Olaoharaa* or ataorlmlnnla* ***1*41 b*Mu* aoeh employ** h* 111*0 any complain! orlnalilolaaor cauaad 10 ba lnatilut*U any proceWm* ot
Impaction under or related lo tNa Aotor haa loatilled or he about la leaIlly In tueh praeeedma orbecauae ollha taerolaaby tuch amployee onMhalf ulmmaal or olhert *
or my tipM atioraed by pita Act." Sec Ipi) ol the Non* Carolina Oaaupaitanal Salary and Iteaitn Aat ol HU
Under im Oecupallarval Solely and HealViAN. lb* larmnWerblnf Day" maan* Uendeyy tnrou*h fiMaya bul So* t not Include Saturday!, bundeya. or Suit Hou*y*
. to. Orreaiar't Sipnoiura.
~T7T7W5?
laauonci Daw _tiarch_lJ} L
79
CoriifniutioA Sht
rr Itar/i No.
CITATION
Standard or Papulation
n
Dticr'.ptlon of Allegad Violation
13 Abatamant Data
2? Ceil 1910.212(a)(5)
39 29 CFil 1910.309(a) National Eloctrioal Coda 'Article JQ2-10 (b).
U'-i 29 cpi 1910.309(a) National Kloctrlcal Coda Artie la 502-ll(b] (2)
Pan blade guards do not ceot rainivum rsrrtiirenento on cooling fans in oloctrical transforao. area of T building and at talophona exchange room in filament atocago warehouse.
March 30, 1//
Failure to provide utilir.ation e.iuipnont (por table electric drill) in H building TA chargin, floor approved for use in Class II, Division 2 hazardous location.
Juno 30, 1979 '
Failure to provide light fixtures on third
floor TA charging area and in CP area second floor of H building and in CP area on second floor and CP area on firat floor of K building approved for Class II hazardous location or provided with enclosures to minimize the deposit of dust on lamps and to pruvent tho
escape of sparks, burning material or hot raotnl.
JutlU 30, 1V79
/
t\
. ; - I , ' v.:**
. -
"r**- -t i*.
:~V\.7';
J&b
mm
.w. ; ... .
:
V
*! LQ
c*.
CITATION
N. C. DEPARTMENT OF LABOR
Offict Of occupational usrnr uo hcalth
4 Vm( I4*Mm
AaMfK, K e. S7M1
4
X TO:
Fiber Industries, Inc. Poet Office Box 4 Sal tsfairy, North Caroline
28144
1. . .H No.
T-<628 V.
2. OSHA I No.
009-79
4. Cilitlon Number
5. Pig. ___________ _ of 6.
TYPE OF ALLEGED VIOLATIONISI: HOO-flsrlous August 22 -25
7. An inspKlion on m*d on . S^pteabar 11, 12, 20-22 j 27-29 19 73
of , p,Kt of tmp|0ymtnt |oclItd ,t:
8. Hlghvay 7Q..Westi Salisbury, North Carolinalnd dtlCfibtd ,, (ol)owl.
9. MJra'frf.nw nf pnTy-etn-[;
id.
Item No.
1
On tn#
of (N mocuo* it m JI#94 th#t you h#w vtofetad CN Norm Carolina Occupational Sataty and Haalth Act of (973,
In th# fcMlOwnnj r#tO#CTr
M. Standard. r?uiation or lection ol th. ACT Aimjedtf violated
ij.
Oncriptlon of alleged viol.tion'
ii. Dit by which alleged violation
muit b. eorr.ct.d
29 CFR 1910.23(c) (1)
No guard rail provided for open section of load ing platform on north end of north/scxith hall at
B building mezzanine level and adequate railing not provided for open-sided walkway in yard an south end of building leading to oil storage tank.
November 16, 1978
2 29 CFR 1910.133(a)
/ / \/ 29 CFR 1910.151(c)
"Repeated"
Eye and face protection (full face ehield to
November 16,
supplement safety glasses) not made available, or
1978
used by, employeee exposed to sulfuric acid in
laboratory of waste treatment plant, sulfuric
acid, hydrochloric acid reagent and corrosives In
testing laboratory of T building.
-
(A) Failure to provide suitable facilitiea for December 21,
quick drenching of the eyee and body for
1978
esployees that handle caustic and catalyzed
sodium sulfite In chemical atorage end,
weighing room of T building, o-chlbrophenol
at OCF storage area an third floor of G
building, end caustic at open surface quench
. tanks at salt bath/pack stripping area of
G building. `
(B) Failure to provide suitable facilities far quick drenching of the eyes far employees that handle sulfuric acid and corrosives in testing laboratory of T building.*
` *; ' * ' v .
'
The law require* that a copy of thte citation than b* prominently potted In a oonaplcuoua place at or near aach place that
an alleged violation referred to In the citation occurred. The citation muat remain potted until all alleged violation! cited therein are
i corrected, or for 3 working dayi\ whichever period It longer.
.
--------------------
--;............. --
------ _i_:i:
WOKTt OP ttVlQTUS
I Any onp^yM Of rpn<nuthe o< >nplp|.< ha t^Wyw th^Ony pwto* 0* ttm Ihw* In IN. clUtten ter W. oon^aan ol > weUMon I. mowonabK rei Ire rtgM W
ccrlMl tuce llm. ter {onecUPrt fry Wing a note, whn rvHC. D.e.nnwra t Later l Ww*im .Per. Wim II ewain* 0*r> ** *> redpt by in. wnpio, w ot nolle.
* propoMd pmnj or note, tret ne pwwfty h bdn* propaM..
--.
"N. .^ptoyM a/yU .
of dWerkrikawe apdnw bwauw wen wnpipyM hM tM My meWnl or InMKuwd or mump m bo lnuiui4 any p*ooMdlnp of
OtpMtianiin<>Pfi.UMIaVtt( Ad orhMWKWto* orl. .Pevt ta Wuiry h kkPi prmMwa w < eM.wrpe.byfcMnwiipioyMenbM.lt olhimMrtwoUtM
' ' . ety h|N aflorM ty IN. A<l* m 1(h) M aw Nertn CaraUna Owue^tMd l^ety an* HmWi Aat e ttn.
*UndwtM0ocup.0ml t.twyaneHMreiAeLtheWmhMWaineOey'iMmUanetyttveupriFrtenr.autdPMnellneluet elu<*ayt. Svnuy*. or et*i.JtoM.yi
tr OV--v-e-t-or-*,-i-lp--r-w--u-r-.`
. L. A., Vstvor, Acting
-r-
Q&ote.fla
,t*.*2i_
ITS m
Continuation Sh*t
0/IH No.
7. OSHA-INo.
CITATION
vr-^28
009-79
P.g. 2___ol_6____
TT
Item No.
Stindjrd or Regulation
12
Description ol Alleged Violation
12
Abatement
Date
29 CFK 1910.22(c)
Mo guard rail or cover provided for open pita November 16,
cn north aide of "D" aerator baain at waste
1978
treatment plant, at R eighteen hydrant location
cn east aide of plant and 'at I? heater in dow-
therm area on east side of plant.
29 CHI 1910.22(a)
Poor housekeeping (metal filter racks, rags,
Novenfcer 16,
paper in west end of air filtration building cn
1978
roof of P buildingj Jacks, boxes of parts,
sheet metal, assorted equipment on floor in
parts room of garage in heavy maintenance; coils
of wire, reels of rope, corrugated boxes, coils
of electrical wiring and cable, box of fluores
cent bulbs and other assorted parts and equip
ment in material storage area of central ahop;
accumulations of oil on floor in stores area of
central shopj scrap lumber, aerosol cans,
broken pieces of insulation, angle iron, welding
rod on grated walking surface at interconnecting
overhead platform on top of K building dow heat
ers; oil on floor along sides of twisters In
L building; oil on floor at head of passageway
in beam storage warehouse; oil on floor at cartcki
staging area in filament warehouse; and stacks
of used corrugated boxes on south dock of J
building) creating a fire and tripping tiazard.
6
29 CFR 1910.22(a)(2)
7allure to maintain floors in baling room of P building and in southeast comer of staple warehouse in a clean arid so far as possible a dry condition to prevent slipping hazards and failure to maintain adequate drainage in baling room of P building.
November 16, 1978
29 era 1910.22(b)(1)
7allure to maintain passageway with no obstruc tion across or in aisle (unlevel lumps and edges and turned vp ends of synthetic mats) that ccxild create a falling hazard at beam
buffing station on mezzanine floor.
November 16, 1978
29 era 1910.23(a)(8)
Failure to provide standard railing or floor hole cover for holes in grated walking surface on top of TA ailo on east aide of plant.
November 16, ' 1978
29 era 1910.110(e) {it) Failure to provide removable fuel container for Immediately
(ii)
IP gas on fork truck fifty-four being used in upon receipt
baling area of P building. '
of citation'
10 29 era 1910.110(b)(6) Failure to remove ignitablo grasses and weeds
(vi)
within ten feet of three IP gas bulk storage
tanks in yard cn northeast side of property.
November 16, 1978
11- 29 era 1910.215(b)(9) (A) No adjustable peripheral tongue guards
provided for abrasive'wheels on pedestal
. grindor in heavy maintenance ahop and on bench grinder iri clean up welding ahop of
T building. .
December 21, 1978
(B) Adjuotabie peripheral tongue guards not
properly adjusted on pedestal grinders in
maintenance area of P building, in heavy
maintenance ahop, and in services welding
. maintenance shop.
.
Innediately upon receipt of citation
Continuation Stoat
' '0/IH No.
7. OSHA-INo.
CITATION
T-U62S
009-79
p19
Item No.
Standard or Ragulation
Oncr!ption ol Alleged Violation
II
Abatement Date
12 29 CFR 1910.25(d)(1) Failure to nark or tag as "Dangerais- Do Not
Immediately
(*)
Use" defective eight foot ladder on roof of
upon receipt
P building, six foot stepladder in electrical of citation
room of T building, sixteen foot ladder cn.
overhead platfora in twister room of L building
and twelve foot ladder on top of TA silo on east
side of plant.
13 29 era 1910.212(a)(1) No guard provided for unused portion of re volving blade on horizontal band saw blade in
central shop.
December 21, 1976
14
15 16
Y- v'*
17 18
29 CFR 1910.242(b)
Failure to reduce air pressure used for cleaninj Immediately
purposes in maintenance shop and outside chip upon receipt
blending area of F building, in north draw
of citation
frame maintenance shop and in CP maintenance
eleven through sixteen in K building to less
than 30 p.s.i.
29 era 1910.176(b)
Failure to store heavy material (cartons of pneumatic conveying equipment) in a stable and secure manner or to.limit storage height to avoid creating a hazard to personnel at rack forty-one in central shop stores area.
29 era 1910.106(e)(2)
(il)(b)
Failure to limit the quantity of flammable
liquids (isopropanol anhydrwis and methanol in
.stores-area on east side of main plant and
ch,lollne base located outside additive prepara
tion room of C building) outside of an inside
etorage room, cabinet, or in any one fire area
to 120 gallons of Class ID liquids.
.
29 era 1910.106(g)(3)
(iv)(d)
Failure to mount gasoline dispensing pumps on a concrete island or-provide suitable means to
prevent collision damage by passing vehicles for two pumps located along payed driveway around plant facilities on east aide of plant.
Immediately upon'receipt of citation
,December 21 1976
,December 21 1978
29 CTR 1910.106(g)(8)
Failure to take adequate precautions ("No Smoking" sign) in area of gasolino dispensing pumps on east side of plant to prevent the ignition of flammable vapors.
November 16, 1978
19 29 era 1910.106(e)(3) Failure to provide natural or mechanical venti December 21,
(v)
lation for paipt house on east side of main
1978
plant 11 ding where combustible paints and
flammable liquids are stored with discharge or
exhaust to a' safe location cu-side building.
V
*
20 29 era 1910.106(e)(2) Failure to keep flammable liquid (acrylic .
Immediately
(iv) "Repeated"
reducer) used for cleaning in paint house, in upon receipt
covered container when not actually being used. of citation
21 29"era 1910.106(e)(6) Failure to bond containers in which flammable Immediately
(ii)
liquid (isopropanol anhydrous) is being trans upon receipt
ferred from-one container to another in beaming of citation
department.of B building.
22 29 era 1910.132(a)
' Pailure-to require the use of safety, toe foot wear for employees working in_ heavy material handling area such as at beam weighing station in B building, .. . .* .y
December 21, 1978
7024y"j- a
Continuation Sh*at
CITATION
1 l/IH No.
T-4623
7. OSHA-lNo.
C09-79 Ptge. . of.
Item
No.
Sundird Of Rrjuliiion
Description of Alleged Violilion
Abitement O.ati-
23 29 era 1910.219(f)
No guard provided for exposed gears on portable December 21,
metered finish apparatus being used in spin
1978
draw cn mezzanine floor of K building.
24 29 CFR 1910.252(a)(2) Failure to separate oxygen and fuel gas cylin Immediately
(iv) "Repeated"
ders in shipping area of stores- building, in
upon receipt
north CP maintenance shop of H building and in of citation
K building airvash room and HP floor level a
niniam distance of twenty feet or by a r.cn-
ccmbustible barrier at least five feet high.
25 29 CFR 1910.252(f)(2) Failure to provide mechanical ventilation for December 21,
welding area in maintenance chop on'mezzanine
1978
floor of B building at north end of north/south
^hallway.
26/ 29 CFR 1910.252(e)(2)
(ill) "Repeated"
y 29 CFR 1910.212(a)(5)
No welding screen provided for welding area in maintenance ahop on mezzanine floor of B build ing at north end of north/south hallway.
Fan blade guards do not meet minimum require ments on cooling fans in electrical transformer ares of T building and at 'telephone exchange room in filament storage warehouse.
November 16, 1978
December 21, . 1978
23 29 CFR 1910.178(b) (11) Failure to provide fork truck being used inside December 21,
29 CFR 1910.178(c)(2) TA silo on east side of main plant building
1973
(vi)(a)
equipped and approved for use in Class II,
Division 1 hazardous location.
29 29 CFR 1910.309(a) National Electrical Code Article 400-10
Failure to provide flexible cord to pipe threader in central ahop eo-cannected to attachment plug that tension will not be trans mitted to conductors or terminal ecrewe.
November 16, 1978
30 29 CFR 1910.309(a)
(A) Cover missing on electrical panel box at November 16,
National Electrical
K five in motor control room of K building.
1978
Code Article 110-17
(B) Adequate enclosure (open, unsecured doors) Imnediately
not provided for two breaker switches at upon receipt
K sixtsen and one at K fifteen on motor . of citation .
control centers along east wall on first -
. floor of K building.
x `- \
31 29 CFR 1910.309(a) National Electrical
Failure to provide light switch in grease pit of garage approved'as a complete assembly for
December 21, 1978
Code Article 501-6(b) Class I, Division 2 hazardous location.
32 29 CFR 1910.309(a) National Electrical Code Article 501-12
Failure to provide.receptacle for air condition December 21,
er in paint house approved for Class I, Division
.1978
2 hazardous location.
33 29 CFR 1910.309(a)
Failure to provide motors for air conditioner
National Electrical paint mixers and pedestal fan in 'paint house
Code Article 501-fi(b) approved for Class I location.
December 21, 1978
31* 29 CFR 1910.309(a) " Failure to provide wiring for air conditioner, December 21,'
National Electrical light fixture,' two mixers and pedestal fan
1978
Code Article 501-4(b) approved for Class I, Division 2 hazardous
35 29 CFR''1910.309(a)
locat.i.d..n;'.riC'; I ' '
*
Failure to provide bin charging switches on ''
December 21,
National Electrical vest wall, 'ground floor of TA silo with duatCoda. Article 502-6(a) . ignition-proof enclosures approved as a cocplete
. 1978
(1) ' ' : .assembly for Class II hazardous location.
70245
> |>
. t. [ 'c'v .
Continuation Sht
.
CITATION
1 1/lH No.
2. OSHA-INo.
*
T-4628
___ 009-79______________
ll.m 12
No. Standard or Rtgulation
D.tcrlptlon of Alleged Violation
Abatement
One
36 29 era 1910.309(a) National Electrical Code Article -502-13
(a)
Failure to provide dust-ignition-proof rocepta-
cle along aouth wall on ground floor of TA ailo approved for Class II, Division 1 hazardous location.
December 21,
' 1978
37 29 C7R 1910.309(a)
Failure to provide Junction box on electrical Deceefcer 21,
National Electrical control valve on blow pot number two in TA alio Code Article 52-4(a) at mezzanine level vith'fcloae fitting cover and
" 1978
(1) without opening through which dust might enter
or sparks or burning material might escape for
Class II, Division 1 hazardous location.
38 29 era 1910.309(a)
Failure to provide switches (inadequately
December 21,
National Electrical secured enclosures) at top of TA ailo on east
1978
Code Article 52-6(b) aide of main plant building with dust-ignition-
proof enclosures approved as a complete assembly
for Class II hazardous location.
39 29 era 1910.309(a) National Electrical Code Article 502-10
(b)
Failure to provide utilization equipment (por table electric drill) in ti building TA charging floor approved for use in Class II, Division 2 hazardous location.
December 21, 1978
40 29 era 1910.309(a)
Failure to provide control switch box enclosure* December 21,
National Electrical for refrigeration units and on TA belt feeder*
1978
Code Article 502-4(b) with close fitting covers .and without openings
(sdasing attachment studs) through wliich dust
might onter or sparks or burning material
might escape for Class II, Division 2 hazardous
location.
A1 29 era 1910.309(a) National Electrical
Code Article 502-12
Failure to provide flexible cords equipped for use as extension cords for portable hand-held tools or other utilization equipment in tool crib of Cp maintenance shop eleven through sixteen in K building' and in TA charging area of building approved for Clasa II, Division 2 hazardous location.
December 21, 1978
42 29 era.1910.309(a)
Failure to provide light fixtures on third
December 21,
National Electrical floor TA charging area and in CP area second
' 1978
Code Article 502-ll(b | floor of H building and in Cp area on second
(2) floor and Cp area on firat floor of K building
approved for, Class II hazardous location or
provided, with enclosures to minimize the deposit
of dust on la/qps and to prevont the escape of
sparks, burning material or hot metal.
#Sqe enclosed copy of Standards Notice 46.
->-.3
70.245
j___ L
N. C. DEPARTMENT OF LABOR
r
*
omct of occutatonm tA/mr mo hcmth
4 WnI |4MtM |Nl(
fUM*t * c. mtt
CITATION
3. TO:
Tiber Industries, Inc. * post Office Box 4
Salisbury, North Carolina
28144
4. Cltltlon Numbvr
One
6. Pip
ol 8.
TYPE OF ALLEGED violation^) < Non-eericua August 22-25
7. An Impiciion wu midi on September 11, 12 , 20-22 A 27-29, 19 8 Highway 70 West. Salisbury, North Carolina________
78
0. Manufacturer of polyester__ |_________________________
of i plici of 4mploymnt loctttd at: _____________________ arxj dscribd ai follows :
On ihi bum of ih Irtfjhtction If u tllogoO (hot vow htv vioUitd iti# Nonh CroUi OccupttioAd
HmIi/i Act of 1973.
In tM laltowng
73!--------- ii.
Slindird. rtgulition
Ittm
or ttction ol th Act
No. ailagadly violalad
IT------------------------------------------------------------------------------ TT----------------------
0i by which
Oncriptlon ol sllsgsd violation
llegud violiiion
mull b. contend
43- 29'CFE 1910.95
A. Subjecting employees in pack stripping G
October 311
building, spin drew K building, staple spinning H building, draw frame platform
1922
J building, polymer recovory unit P building\
to sound levels exceeding those listed in
Table G-16 and failure to' provide a ccntinuln !
effective hearing conservation program, that
includes feasible engineering and administra
tive controls.*
1 1
r
1 1 i,, 1 !*
X .
B. Personal protective/equipment (ear plugs, muffs, or other aoina) not used by employees, in pack etripping'O-building subjected to
, sound -levels exceeding those listed in Tsole ' Q-16 during the interim period required to
achieve compliance by engineering or admlnistrativa means.
Enclosed Quidsline Plan NCSU -IKS 3AH-1 (or sisdlar) to- be oomplsted and copy returned to the NO Department of Labor, OSHA Division by Deceeiier 29, 1978.
November 16, 1978
Progress reports -met be filed Kith this office,
during the abatement period, on the following
e.
dates t -
" ..
January 31, 1922
. * * , ,, .... ,
` April 30, 1922
!v
^ t *. 4 ;
* ...
- July 31, 1922
` T ' . * i * .
; v-'X
TTii law raqulrsi |ht copy of thle citation (hall ba promlftanlly polled In a conspicuous placi at or naar aach place that
an alleged violation referred to In the citation occurred. The citation muil remain polled unll all alleged violation! cited therein are
corrected, o'r.ilor 3 working day**, whichever period la longer.
.
\
, 1I s .. --V .
*i4HTt of fupcoirm
Any tmptoyM or fprMnUtN< of tmpioy*** <yho MIvm thri any period of lima Ha*4 In ftk citation lor iho ootmUo* of a vfotaUon la wvoaaonablt Hm if* righno
conlaal tuaft lima ter ooffactlon by f|Hnf * nofioa uHb) fa N. C. Dapartmam of Labor alhaa0draaa>0oawllNn f worilng Ooya af y'afaoalpOylbaamptoyo* olnoOo*
of propoaad panalry or nodea lhaf M oanaity It baing prapo^o4.
--f *'
No amofoyoa iHal ba dltctaigcd or tftacrfmlnaiad agalnai bocauaa tuoh ampityaa haa RM4 any oomoUkH or hntMwiH or aioaaO la ba InatlluM any prooaading or
Inapaclion umMr or ralnad lo IMa Act or haa iMUhad or la about to loatify In tudi prooaaomg or bacauaa of tf* lurtka by luoA amployoo on baHaU of Mmaalf or otr*n
of vty right aftoroad by IMa Act* aa 1(h) ai W+ Morin Carolina OooupauonaJ laMry y* Haatm Aal of 1971
. ..
/
*Un0arr lha Ooaupatlonal UMfy and Hoaftl Art, ff* Iwm'YtartMf Ooy^mOM MpnOoyo tfvough Fridaya but #oao not InohKla Saturdory. >uAOaya. orSSiai laHoHoaya.
14 CiracW'ior'.'IltlIknOnn.aealjrMa
* .*.
\l .:. %. '*---iW_-_-a-r-n-*-.v* 'V^e j.. . 3,,11-
7?
o. ys.
**'
CM
O t*
* ....
N. C. DEPARTMENT OF LABOR
OFFICE OF OCCUPATIONAL SAFETY AND HEALTH 4 Will Edanton Street Raleigh, N. C. 27601
CITATION
i 3. TO:
Fiber Industries, Inc. Post Office Box 4
Salisbury, North Carolina
28144
1. SO/IH No.
T-4628
2. OSHA-1 No.
009-79
Citation Numh.r
Page
^
One
4. 4 ..
,"of6.
^
TPE OF ALLEGED VIOLATION(S): Non-seriOUS August 22-25
A.n i.nsp.ection was made on Se*p*1tember 11, 12*,` 20-22 & 27-29, 19 7* 8 Highway 70 West, Salisbury, North Carolina________________
Manufacturer of polyester___________________________________
of a place of employment located at: ' ` '7' ________________ and described as follows : 1
On the basis of the inspection it is alleged that you have violated the North Carolina Occupational Safety and Health Act of 1973, in the following respects:
11.
Standard, regulation :em or section of the Act Jo. allegedly violated
12.
Description of alleged violation
13.
Date by which alleged violation ' must be corrected
3 29 CFR 1910.95
A. Subjecting employees in pack stripping G
October'31^ "
building, spin draw K building, staple
1922
spinning H building, draw frame platform
J building, polymer recovery unit P building
to sound levels exceeding those listed in
Table G-l6 and failure to provide a continuing
effective hearing conservation program, that
includes feasible engineering and administra
tive controls.*
B. Personal protective equipment (ear plugs, muffs, or other means) not used by employees, in pack stripping G building subjected to sound levels exceeding those listed in Table G-16 during the interim period required to achieve conpliance by engineering or adminis trative means.
November 16, ' 1978
-_\
*Enclosed Guideline Plan NCSU IKS SAH-1 ("" similar) to be completed-and copy returned -to the NC Department of Labor, OSHA Division by
December.29, 1978.
-
Progress reports must be filed with this office, during the abatement period, on the following dates:
January 31, 197? April 30, 1929
July 31, 1922
, , . I , , r~ .
'he law requires that a copy of this citation shall be prominently posted in a conspicuous place at or near each place that alleged violation referred to in the citation occurred. The citation must remain posted until all alleged violations cited therein are rrected, or for 3 working days', whichever period is longer.
7',,'
'
RIQHTS OF EMPLOYEES
ny employe* or rvpresentative of employees who believes the! eny period of time fixed In this citation for the correction of a violation is unreasonable has the right to <,
test such time for correction by filing s notice with the N. C. Department of Labor atthe address above within 15 working days of the receipt by the employer of notloe
proposed penalty or notice that no penalty Is being proposed.
v'
No employee shall be discharged or discriminated against because such employee has filed any complaint or Instituted or caused to be Instituted any proceeding or '
-wction under or related to this Act or has testified or is about to testify in such proceeding or because of the exercise by such employee or behall of himself orothers
my right afforded by this Act * See 5(h) of the North Carolina Occupational Safety and Health Act of 1673.
jnder the Occupational Sslety and H<
ctjfthe term "Working Day" means Mondays through Fridays but does not Include Saturdays, Sundays, or Stale Holidays. '
director s Signature
L# Ae Weaver, Acting
usuarvce n.,, October 31.
OSHA-2
____ ib_28_
Confirmation Sheet
- --
1. SO/IH No.
2. OSHA-1N0.
CITATION
T-4628
009-79____________
Page . . of. 6
Item No.
Standard or Regulation
12
Description of Alleged Violation
13
Abatement - Date '
-36 29 CFB 1910.309(a) - Failure to.provide -dust--ignition-proof-recepta December-21,
National Electrical cle along south wall on ground floor of' TA silo
1978
Code Article 502-13 approved for Class Uf Division 1 hazardous'-;,
(a) :
location.
.
37 29 CFR 1910.309(a)
Failure to provide junction box on electrical December"21,
National Electrical control valve on blow pot number two "in TA silo -
1978
Code Article 502-4(a) at mezzanine level with close fitting cover and
(1) without opening through which dust might enter
or sparks or burning material might escape for
Class II, Division 1 hazardous location.
3 29 CFR 1910.309(a)
Failure to provide switches (inadequately
December 21,
National Electrical secured enclosures) at top of TA silo on east
1978
Code Article 502-6(b) side of main plant building with dust-ignition-
proof enclosures approved as a conplete assembly
for Class U hazardous location.
39 29 CFR 1910.309(a) National Electrical Code Article 502-10
(b)
Failure to provide utilization equipment (por table electric drill) in H building TA charging floor approved for use in Class II, Division 2 hazardous location.
December 21, 1978
40 29 CFR 1910.309(a)
Failure to provide control switch box enclosures December 21,
National Electrical for refrigeration units and an TA belt feeders-
1978
Code Article 502-4(b) with close fitting covers and without openings
(missing attachment studs) through which dust
might enter or sparks or burning material
might escape for Class II, Division 2 hazardous
location.
41 29 CFR 1910.309(a) National Electrical
Code Article 502-12
Failure to provide flexible cords equipped for use as extension cords for portable hand-held tools or other utilization equipment in tool crib of CP maintenance shop eleven through sixteen in K building and in TA charging area of H building approved for Class II, Division 2 hazardous location.
December 21, 1978
42 29 CFR 1910.309(a)' Failure to provide light fixtures-on third :
December 21,
National Electrical floor TA charging area and in CP area second
1978
Code Article 502-ll(bj) floor of H building and in CP area on second
(2) floor and CP area on first floor of K building
approved for Class II hazardous location or
provided with enclosures to minimize the deposit
of dust on lamps and to prevent the escape of
sparks, burning material or hot metal.
See enclosed copy of Standards Notice 46.
n t
02475
OSH A-2
Con^nuation Sheet
CITATION
1. SO/tHNo. T-4628
2. OSHA-INo.
009-79
Page _4__ of
6
a
Item
No.
11 Standard or Regulation
12
Description of Alleged Violation
.'
13- . . : Abatement . . ` Date
23 29 CFR 1910.219(f)
No guard provided for exposed gears on portable December! 21, -
metered finish apparatus being used in spin
r"i978;
draw on mezzanine floor of K building. '
-24 29 CFR 1910.252(a)(2) Failure to separate oxygen and fuel .gas cylin-:. Innediately-/:'
(iv) "Repeated"
ders in shipping area of stores building, in
upon receipt '. '
north CP maintenance shop of H building and in of citation.
K building airwash room and HP floor level a
minimum distance of twenty feet or by a non-
combustible barrier at least five feet high.
25 29 CFR 1910.252(f)(2) Failure to provide mechanical ventilation for December 21,-
welding area in maintenance shop, on mezzanine
1978
floor of B building at north end of north/south
v hallway.
26 29 CFR 1910.252(e)(2) No welding screen provided for welding area in November.'16,r
(ill) "Repeated"
maintenance shop on mezzanine floor of B build
,1978
ing at north end of north/south hallway.
27 29 CFR 1910.212(a)(5) Fan. blade guards do not meet mini mum require-- . ' December. 21,
ments an cooling fans in electrical transformer
- .;-i978
area of T building and at telephone exchange
room in filament storage warehouse.
28 29 CFR 1910.178(m)(11 ) Failure to provide fork truck being used inside December 21, '
29 CFR 1910.178(c)(2) TA silo on east side of main plant building
' r' ,1978
(vi)(a)
equipped and approved for use in Class II,
Division 1 hazardous location.
29 29 CFR 1910.309(a) National Electrical
Code Article 400-10
Failure to provide flexible cord to pipe threader in central shop so-connected to attachment plug that tension will not be trans mitted to conductors or terminal screws.
November l6,' 1978
30 29 CFR 1910.309(a) National Electrical Code Article 110-17
(A) Cover missing on electrical panel box at November 16,
' K five in motor control room of E';building.
1978
(B) Adequate enclosure (open, unsecured doors) Inmediately
not provided for two breaker switches at upon receipt
K sixteen and one at K fifteen on motor
of citation
control centers along east wall on first
floor of K building.
31 29 CFR 1910.309(a)
Failure to provide light switch in grease pit
National Electrical of garage approved as a conplete assembly for
Code Article 501-6(b) Class I, Division 2 hazardous location.
December 21, ' ' 1978
32 29 CFR 1910.309(a) National Electrical Code Article 501-12
Failure to provide receptacle for air condition December 21, .
er in paint house approved for Class I, Divisioi , : 1978
2 hazardous location.
:.
33 29 CFR 1910.309(a)
Failure to provide motors for air conditioner
National Electrical paint mixers and pedestal fan in paint house
Code Article 501-8(b) approved for Class I location.
December 21, 1978
34 29 CFR 1910.309(a)
Failure to provide wiring for air conditioner, December 21,
National Electrical light fixture, tw> mixers and pedestal fan
1978
Code Article 501-4(b) approved for Class I, Division 2 hazardous
location.
' -'
35 29 CFR 1910.309(a)
Failure to provide bin charging switches an
December 21,
National Electrical west wall, ground floor of TA silo with dust-
1978
Code Article 502-6(a) ignition-proof enclosures approved as a complete
(1) assembly for Class II hazardous location.
OSHA-2
T&Z47&
Conii^ation Sheet
1. SO/IH No.
2. OSHA-INo.
CITATION
T-4628
009-79 Page _3__ of
6
Item No.
11 Standard or Regulation
'2
Description of Alleged Violation
13
.
Abatement
Date
12 29 CFR 1910.25(d)(1) Failure to'mark or tag as "Dangerous- Do Not ;/ Immediately j
(*) Dse" defective eight foot ladder on roof of-.h- upon receipt-T-
P buildingt six foot stepladder in electrical of citation '
room of T building, sixteen foot ladder an
overhead platform, in-twister room of L building and twelve foot ladder on top of TA silo on easl -
-
side of plant.
13 29 CFR 1910.212(a)(1) No guard provided for unused portion of re-
- volving blade on horizontal band saw blade in
central shop. ~
;* -
December 21, " . ,.....: 1978
14 29 CFR 1910.242(b)
Failure to reduce air pressure used for cleaning purposes in maintenance shop and outside chip blending area of F building, in north draw frame maintenance shop and in CP maintenance eleven through sixteen in K building to less
than 30 p.s.i.
Immediately; upon receipt of citation
'
15 29 CFR 1910.176(b)
Failure to store heavy material (cartons of . pneumatic conveying equipment) in. a stable and secure manner or to limit storage height to avoid creating a hazard to personnel at rack forty-one in central shop stores area.
Immediately upon receipt of citation
.
16 29 CFR 1910.106(e)(2) Failure to limit the quantity of flanmable
December 21,
(ii)(b)
liquids (isopropanol anhydrous and methanol in
1978
stores area on east side of main plant and
chloline base located outside additive prepara
tion room of G building) outside of an inside
storage room, cabinet, or in any one fire area
to 120 gallons of Class IB liquids.
17 29 CFR 1910.106(g)(3) Failure to mount gasoline dispensing pumps on December 21,
(iv)(d)
a concrete island or provide suitable means to
1978
prevent collision damage by passing vehicles
for two pumps located along paved driveway
around plant facilities on east side of plant.
18 29 CFR 1910.106(g)(8) Failure to take adequate precautions ("No
November 16,
Smoking" sign) in area of gasoline dispensing-
1978
pumps on east side of plant to prevent the
ignition of flammable vapors.
19 29 CFR 1910.106(e)(3) Failure to provide natural or mechanical venti December 21,
(v)
lation for paint house on east side of main
.1978
plant building where combustible paints and
flanmable liquids are stored with discharge or
exhaust to a safe location outside building. ''
20 29 CFR 1910.106(e)(2) Failure to keep flanmable liquid (acrylic
Immediately-f'
(iv) ''Repeated"
reducer) used for cleaning in paint house, in' upon receipt;
covered container when not actually being used. of citation
21 29 CFR 1910.106(e)(6) Failure to bond containers in which flanmable Immediately '
(ii)
liquid (isopropanol anhydrous) is being trans upon receipt
ferred from one container to another in beaming of citation
department of B building.
22 29 CFR 1910.132(a)
Failure to require the use of safety toe foot wear for employees working in heavy material handling area such as at beam weighing station
in B building.
December 21, ... 1978
702477
OSHA-2
ContifcAation Sheet
1. SO/IH No.
2. OSHA-INo. '
1
CITATION
T-4626
009-79
Page_l_of_6
Item 12 No. Standard or Regulation
Description of Alleged Violation
13 Abatement.
. Date .'
29 CFR 1910.22(c)
Ho guard rail or cover provided for open pits . Novemberi6,'
on north side of "D" aerator basin at waste
\ 1978
treatment plant, at R eighteen hydrant location
an east side of plant and at EF heater in dow-.
therm area on east side of plant.
29 CFR 1910.22(a)
Poor housekeeping (metal filter racks, rags,
November 16, *
paper in west end of air filtration building on
/ 1976
roof of p building; jacks, boxes of parts,
sheet metal, assorted equipment on floor in
parts room of garage in heavy maintenance; coils
of wire, reels of rope, corrugated boxes, coils
of electrical wiring and cable, box of fluores
cent bulbs and other assorted parts and equip- -
ment in material storage area of central shop;
accumulations of oil on floor in stores area of
central shop; scrap lumber, aerosol cans, .
broken pieces of insulation, angle iron, welding
rod on.grated walking surface at interconnecting
overhead platform, on.tcp of. K building .dow heat
ers; oil on floor along sides of twisters in
L building; oil on floor at head of passageway
in beam storage warehouse; oil on floor at cartcjn
staging area in filament warehouse; and stacks
of used corrugated boxes on south dock of J
building) creating a fire and tripping hazard.
29 CFB 1910.22(a)(2)
Failure to maintain floors in baling room of P building and in southeast comer of staple warehouse in a clean and so far as possible a dry condition to prevent slipping hazards and failure to maintain adequate drainage in baling room of P building.
November 16, 1978
29 CFR 1910.22(b)(1)
Failure to maintain passageway with no obstruc tion across or in aisle (unlevel lunps and edges and turned ip ends of synthetic mats) that could create a falling hazard at beam buffing station on mezzanine door.
November 16, 1978
29 CFR 1910.23(a)(8)
Failure to provide standard railing or door ' November-16,
hole coyer for holes in grated walking surface
. 1976
an top of TA silo on east side of plant.
-
29 CFR 1910.110(e)(4) Failure to provide removable fuel container for Immediately ,
(ii) . '
IP gasman fork truck'fifty-four being-used inv upon receipt
' ballnglarea'of P building.-
*
of citation;
i&.VV'
29::c^i9ip.iio(b)^6)
" ' .-"..-r-'i~
^Failure'to.r
.V - -
rre^ignitabln.'grasses' and/weeds-sv--
Kovaiiber. l6|v
^within ,i;en ;feet^of,titee""'*iP 'gas, *bu"lk stora*g"e`^mi-
^tanlS?iniyard`:'an'northeast- side iof property.^Jh,
................
29 CFR 1910.215(b) (9)
(A) No adjustable peripheral tongue guards? provided for abrasive wheels an pedestal. grinder in heavy maintenance shop and an bench grinder in clean up welding shop of
T building.
Deceniber' 21,'" ' 1978
(B) Adjustable peripheral tongue guards not properly adjusted on pedestal grinders in maintenance area of P building, in heavy maintenance shop, and in services welding maintenance shop.
Immediately upon receipt of citation
7024lb
OSHA-2
*
CITATION
N. C. DEPARTMENT OF LABOR
OFFICE OF OCCUPATIONAL SAFETY AND HEALTH 4 Wnt Ednton StrMt Raltlgh, N. C. 27601
3. TO:
Fiber Industries, Inc. . Post Office Box 4 Salisbury, North Carolina
28144
1. SO/IH No. T-4628
2. TOSHA-1 No. ' 009-79
One - ; '
' of 6.
` ' " '
"6
TYPE OF ALLEGED VIOLATION(S): Non-serious August 22-25
7. An inspection was made on September 11, 12, 20-22 & 27--29 ig
of a place of employment located at:
3.. Highway 70 West. Salisbury, North Carolinaand described as follows:
9. Marmfar.+.iirRr nf polyester'
_________ :
Item No.
On the basis of the inspection it is alleged that you have violated the North Carolina Occupational Safety and Health Act of 1973. in the following respects:
TM1.
Standard, regulation or section of the Act
allegedly violated
i.
Description of alleged violation
13.
' Date by which .
alleged violation
must be corrected *
i 29 ere 1910.23(c) (i)
No guard rail, provided for open section of load ing platform on north end of north/south hall at B building mezzanine level and adequate railing not provided for open-sided walkway in yard on .. south end of building leading to oil storage tank.
November 16,~" 1978
2 29 CFR 1910.133(a) Bye and face protection (full face shield to
November 16,
supplement safety glasses) not made available, or
.. 1978
used by, employees exposed to sulfuric acid in
laboratory of waste treatment plant, sulfuric
acid, hydrochloric acid reagent and corrosives in
testing laboratory of T building.
3 29 ere 1910.151(c) "Repeated"
(A) Failure to provide suitable facilities for December 21,
quick drenching of the eyes and body for
1978
employees that handle caustic and catalyzed
sodium sulfite in chemical storage and
weighing room of T building, o-chlorophenol
at OGP storage area on third floor of G
building, and caustic at open surface quench
tanks at salt bath/pack stripping area of
G truilding.
(B) Failure to provide suitable facilities for-
quick .'drenching of the eyes for employees,
'
`
- *'t
t.hnt. handle, sulfuric' acid and corrosives' V
- in testing`laboratory of T building.*
' A.' r ' . - - '
,.
fk. r*V
V:":;':-''
./ , ,
...\
The law requires that a copy of this citation shall be prominently posted In a conspicuous place at or near each place that n alleged violation referred to in the citation occurred. The citation must remain posted until ail alleged violations cited therein are orrecled, or for 3 working days*, whichever period is longer.
RIGHTS OF EMPLOYEES
Any employee or representative of employees who believes that any period of time fixed in this citation for the correction of a violation Is unreasonable has the lightto intest such time lor correction by filing a notice with the N. C. Deparimentof Laborattheaddress above within 15 working day* ofthareceiptbylheempioyerof notice proposed penalty or notice that no penalty Is being proposed. 'No employee shall be discharged or discriminated against because such employee has filed any complaint or instituted or caused to be Instituted any proceeding or spechon under or related to this Act or has testified or is about to testify in such proceeding or because of the exercise by such employee on behslf of himself or others any right afforded by this Act." See 5(h) of the North Carolina Occupational Safety and Health Act of 1973.
'Under the Occupational Safety and Health Act,
*Y/orking Day" means Mondays through Fridays but does not include Saturdays. Sundays, or State Holidays.
Director's Signature
L. A. Weaver, Acting
L.u.nc. n... October 31.,,28_
OSHA-2
Mvr*- ion
70247 fl
1. SO/IH No.
2. OSHA-1 No.
N. C. DEPARTMENT OF LABOR
OFFICE OF OCCUPATIONAL SAFETY AND HEALTH 4 Wnt EdMlon Street Raleigh, N. C. 27601
CITATION
AMENDED
3. TO:
Fiber Industries, Inc. Post Office Box 4 Salisbury, North Carolina
28144
B-0436
007-79
4. Citation Number
Two
5. Page
of 6/
IN RESPONSE
-------PLEASE REFER TO
ii
s
%
$4
TYPE OF ALLEGED VIOLATION(S) : Non-SeriOUS
Sept. 5,6,7,8,11,12,13,14 and
OSHA FILE NO. _24i6/)S_l__
2*1
7. An inspection was made on Aufi. 22,23,24,25,28,29,30,31,
19 78 of a place of employment located at:
3 Highway 70 West. Barber Junction, Salisbury, North Carolina ______ and described as follows : 1
3 Production of polyester fiber_________________________________
Item No.
On the basis of the inspection it is alleged that you have violated the North Carolina Occupational Safety and Health Act of 1973, in the following respects:
Standard, regulation or section of the Act
allegedly violated
12.
Description of alleged violation
Date by which " alleged violation must be corrected \
THE ABOVE CITATION NUMBER, ISSUED 1-10-79
|
TMENE0 AS SEr FORTH BELOW. THIs'ciTATION is"*"
AMENDED TO EXTEND THE ABATEMENT DATE ONLY.
May 31, 1979, >:
o* V.>|M
The law requires that a copy of this citation shall be prominently posted in a conspicuous place at or near each place'thata in alleged violation referred to in the citation occurred. The citation must remain posted until ail alleged violations cited therejna ;orrected, or for 3 working days*, whichever period is longer.
RIGHTS OF EMPLOYEES
, .- . ti
Any employee or representative of employees who believes that any period of time fixed in this citation for the correction of a violation is unreasonablehas thejiglj
:ontest such time for correction by filing a notice with the N. C. Department of Labor at the address above within 15 working days of the receipt by theemptoyerofn `
;f proposed penalty or notice that no penalty is being proposed.
.'*?
"No employee shall be discharged or discriminated against because such employee has filed any complaint or instituted or caused to be Instituted any proceeding^
Tspection under or related to this Act or has testified or is about to testily in such proceeding or because of the exercise by such employee on behalfof himselforoftattjj
I any right afforded by this Act.'* See 5(h) of the North Carolina Occupational Safety and Health Act oc f 1973.
*** >*
`Under the Occupational Safety and Health Act. the term( rkrfig Day" means Mondays through Fridays but does not include Saturdays, Sundays, orStateHa
4 Director s Signature
AMO
Jr A WEAVER, III, Acting
. Issuance Date.
-1
m"w tX'fV.
i '-osHA-i?
4700
t UL
SC!
N. C. DEPARTMENT OF LABOR
OFFICE OF OCCUPATIONAL SAFETY AND HEALTH 4 Wwt Edenlon Street Raleigh, H. C. 27601
AMENDED
3. TO
Fiber Industries, Inc. Post Office Box i+
Salisbury, North Carolina
28144
i. SO/IH No.
2. OSHA-1 No.
B-0436 ' ''
007-79
: -'r'. '
-v.- ; / y '/ .
^
. - --O
1 DATF
A, 1979
,, - , * '
. . .yi'
;_
.' J'-. -
SUBJECT: Citation for Alleged Occupational Safety and Health Violation(s) ... .
-
"v .
An inspection of a workplace under your operation, ownership, or control has revealed conditions which we believe ^
do not comply with the provisions of the North Carolina Occupational Safety and Health Act of 1973. The nature of
such alleged violation(s) is described in the enclosed citation with references to applicable standards, rules,
regulations, and provisions of the said Act. These conditions must be corrected on or before the date shown to the right *
of each violation therein.
'" ,
POSTING
The Act requires that a copy of the enclosed citation(s) be prominently posted "in aconspicuous place upon receipt";
at or near each place a violation referred to in the citation occurred. It must remain posted until all violations cited' -.1
therein are corrected, or for 3 working days, whichever period is longer. A sufficient number of copies of the attached
citation(s) should be prepared to permit posting in accordance with the requirements of the Act The Act contains
penalties for violation of the posting requirements.
'
If you contest the citation you must post a notice to this effect near the citation contested.
ALLEGED VIOLATIONS & RESPONSE
Alleged violations that are not contested shall be corrected to eliminate the hazard within the abatement period; ...
specified in the citation. Failure to correct an alleged violation within the abatement period may result in a further
proposed assessment of penalties.
As to alleged violations, you are directed to promptly advise the Director as to the specific corrective action on each -
such violation and the date of such action. OSHA 2-D forms and self-addressed envelopes are enclosed for your use.
Alleged violations having longer abatement periods will require as specified on the citation, progress reports de-'
tailing what has been done, what remains to be done, and the time needed to fully abate each such violation. When the -
alleged violation is fully abated, the Director shall be so advised using the OSHA 2-D forms.
'
REQUEST FOR ABATEMENT EXTENSION You must request required extensions of abatement periods in writing prior to final abatement dates. Extensions
may be granted if the delays are unavoidable and interim employee protection methods are provided. All requests must be directed to the OSHA Director. Failure to obtain extensions prior to the abatement dates may result inadditional failure to abate penalties.
PROPOSED PENALTIES
Enclosed:
Proposed penalty notice enclosed
No proposed penalties
B No change in penalty -- Amended citation issued
:
INFORMAL CONFERENCE
.
,
If upon receipt of a citation you have any questions or misunderstandings relative to the citation, you may discuss .
the item by telephone or arrange an informal conference with the Director or his designee. :i.; , -.
CONTESTING
:\
You have the right to contest the citation(s), the proposed penalties, or both, before the Occupational Safety and;
Health Review Board. The Review Board is an independentquasi-judicial agency with authorityto issue decisions re-'-'C;
garding citations and proposed penalties. If you do contest you must so notify the Director within 15 working days \
after receipt of this certified mail notice regarding alleged violations and proposed penalties.Tf you fail to contest '
within the 15 working day period, the citation and proposed penalties shall be deemed to be a final order and not .:-;
subject to review by any court or agency.
-
Any employee or representative of employees may file a notice to contest the time stated in the citation for the abate-'.
ment of the alleged violation(s). The appeal must be filed within 20 calendar days of citation receipt.
J . I .
FOLLOW-UP INSPECTION
>
Follow-up inspections may be conducted to ascertain that you have posted the citation(s) as required by the Actand :
corrected the alleged violations as you have reported. The Act provides that whoever knowingly gives false
information is subject to a fine up to $10,000, imprisonment up to 6 months, or both.
- -
FAILURE TO ABATE VIOLATIONS Violations not corrected by the final abatement dates may result in additional failure to abate penalties. ~ \.: If you wish additional information, you may direct such request to the undersigned or Director, OSHA Enforce-
ment at the address listed above.
.
N.C. Department of Labor
5.
A. WEAVER, 111, Acting
OSHA Director -
. . ..
OSHA2C '
*>'* 'A : f.. \S'.
Si
N. C. DEPARTMENT oflabor OFFICE OF OCCUPATIONAL SAFETY AND HEALTH
P. 0. Box 27407 Raleigh. N. C. 27611
3.TO Fiber Industries, Inc. P.O. Box 4 Salisbury, N.C. 28144
1. SOT^No. B0436
2. OSHA-1 No. 007-79
$
1 date January 10, 1979
SUBJECT: Citation for Alleged Occupational Safety and Health Violation(s)
. ' '--
An inspection of a workplace under your operation, ownership, or control has revealed conditions which we believe do
not comply with the provisions of the North Carolina Occupational Safety and Health Act of 1973. The nature of such
alleged violation(s) is described in the enclosed citation with references to applicable standards, rules, regulations, and
provisions of the said Act. These conditions must be corrected on or before the date shown to the right of each violation
therein.
POSTING
The Act requires that a copy of the enclosed citation(s) be prominently posted "in a conspicuous place upon receipt" -
at or near each place a violation referred to in the citation occurred. It must remain posted until all violations cited _ :
therein are corrected, or for 3 working days, whichever period is longer. A sufficient number of copies of the attached.
citation(s) should be prepared to permit posting in accordance with the requirements'of the Act. The Act contains. "
penalties for violation of the posting requirements.
, ` .. - .
If you contest the citation you must post a notice to this effect near the citation contested.
ALLEGED VIOLATIONS & RESPONSE
Alleged violations that are not contested shall be corrected to eliminate the hazard within the abatement period ,
specified in the citation. Failure to correct an alleged violation within the abatement period may result in a further pro
posed assessment of penalties.
As to alleged violations, you are directed to promptly advise the Director as to the specific corrective action on each
such violation and the date of such action. OSHA 2-D forms and self-addressed envelopes are enclosed for your use.
Alleged violations having longer abatement periods will require as specified on the, citation, progress reports de
tailing what has been done, what remains to be done, and the time needed to fully abate each such violation. When the
alleged violation is fully abated, the Director shall be so advised using the OSHA 2-D forms.
REQUEST FOR ABATEMENT EXTENSION
You must request required extensions of abatement periods in writing prior to final abatement dates. Extensions may
be granted if the delays are unavoidable and interim employee protection methods are provided. All requests must be
directed to the OSHA Director. Failure to obtain extensions prior to the abatement dates may result in additional
failure to abate penalties.
"
PROPOSED PENALTIES
Enclosed: EH Proposed penalty notice enclosed
No proposed penalties No change in penalty -- Amended citation issued
. - V.
INFORMAL CONFERENCE
/
If upon receipt of a citation you have any questions or misunderstandings relative to the citation, you may discuss the
item by telephone or arrange an informal conference with the Director or his designee.
CONTESTING
'
' ...
You have the right to contest the citation(s), the proposed penalties, or both, before the Occupational Safety and ;"
Health Review Board. The Review Board is an independent quasi-judicial agency with authority to issue decisions re-:
garding citations and proposed penalties. If you do contest you must so notify the Director within 15 working days after'-.: .
receipt of this certified mail notice regarding alleged violations and proposed penalties. If you fail to contest within the '
15 working day period, the citation and proposed penalties shall be deemed to be a final order and not subject to review ' - ;
by any court or agency.
. -
'.
An employee or representative of employees may file a notice to contest the time stated in the citation for the abate-" :
ment of the alleged violation(s). The appeal must be filed within 20 calendar days of citation receipt. -
FOLLOW-UP INSPECTION
,
Follow-up inspections may be conducted to ascertain that you have posted the citation(s) as required by the Act and
corrected the alleged violations as you have reported. The Act provides that whoever knowingly gives false information : _ _
is subject to a fine up to $10,000, imprisonment up to 6 months, or both.
.. .
FAILURE TO ABATE VIOLATIONS Violations not corrected by the final abatement dates may result in additional failure to abate penalties. ` If you wish additional information, you may direct such request to the undersigned or Standards and Inspections Di
rector at the address listed above.
70248?
m
N. C. DEPARTMENT OF LABOR Office of Occupational Safety and Health
NOTIFICATION OF PROPOSED PENALTY
1.SO/IH No. .B0436
2. OSHA-1 No, ' ;
V--- '-^.v" 007-79;^
3. TO: Fiber Industries, Inc. P.0. Box 4 Salisbury, N.C. 28144
... . r*-
-'.'f ; .*j.
On the 4--------I^nth---------- day of____January, i9_ZL_,aCitation(s) was (were) issued toyou.in'v'v. i accordance with the provisions of section 12(a) of the North Carolina Occupational Safety and Health Act of 1973:-:.'-\ hereinafter referred to as the Act. You were thus notified of certain alleged violations of the Act, as specified in that. Citation(s).
YOU ARE HEREBY NOTIFIED that pursuant to the provisions of sections 13 or 14 of the Act, the penalty(ies) set'
forth below is/are being proposed, based on the above Citation(s):
'
5. SERIOUS VIOLATIONS Citation No.
` 1 . 1
i' ,
Proposed Penalty Due
ONE Item 1 Item 2A Item 2B
$600.00 ' ' $600.00 .
1
6. OTHER VIOLATIONS Citation No.
Item No.
>v
':v ....
j Proposed Penalty Due;> :
:
* 1 ..
7. Total for all Alleged Violations
$1200.00
*The above penally is DUE WITHIN 15 WORKING DAYS after receipt of this notice and may be mailed along with Form OSHA-2D.O'heC"./ .
penalty shown for "Other Violations" has been reduced by 50% for the anticipated corrective action taken within the prescribed abatement period. If.< ' v ;
a particular alleged violation is not corrected within this period, an automatic additional penalty of 50% will be proposed for each violation. However,
if you contest an alleged violation or proposed penalty in good faith before the Review Board, the period for correction of the violation or payment of ,..'T
penalty does not begin to run until the entry of a final order by the Review Board affirming the Citation. The proposed penalty is exclusive of such ; ,/
other additional penalty as may subsequently be proposed for failure to correct a violation within the abatement period.
,1'
The payment of penalties ts to be made by certified check or money order, payable to the order of North Carolina Occupational Safety and Health Administration, Department of Labor, Raleigh, N. C.
'
YOU ARE FURTHER NOTIFIED that the aforesaid Citation(s), this Notification, and the proposed assessment shall be deemed final and not.:..
subject to review by any court or agency, unless, within 15 working days from the date of receipt of this notice, you notify the official named below in- ;
writing that you intend tocontest the Citation or this Notification of Proposed Penalty before the Review Board. The Review Board is an independent :
quasi-judicial agency with authority to issue decisions regarding citations and proposed penalties.
- v
There is no requirement that this Notification be posted.
V "V
702487
Acting 8. Director's Signature
L.A. Weaver
January 10,;;; Issuance Date.
CITATION
N. C. DEPARTMENT OF LABOR
OFFICE OF OCCUPATIONAL SAFETY AND HEALTH 4 Wul Etfmton Stmt lUMgh, N. C. 37801
3` T0: Fiber Industries, Inc.
P.0. Box 4 Salisbury, N.C. 28144
1. S07m No.
B0436
2. 0SHA-1 No.
007-79
4. Citation Number. 5. Page ___ 1_
JQHE_
'y ' . 5-
of 6. ____ 1
sv`Mm
TYPE OF ALLEGED VOLATIJ^^r^^
August 22,23,24,25,28,29,30,31
. An inspection was made on ;
19 78
3 Highway 70 West, Barber junction, Salisbury, N.C.
3 Production of polyester fiber ____________ '
a' 4
y > V-V;
of a place of employment located at: ; :
, vV*/
_________ ___ :___ and described as follows,:
Item No.
On the basis of the inspection it is alleged that you have violated the North Carolina Occupational Safety end Health Act of '973, in the following respects:
11. Standard, regulation or section of the Act allegedly violated
12.
Description of alleged violation
. 13T Date by which - alleged violation ;
must be corrected
North Carolina General Statute 95-129(1)
Failure to provide employees a place of employment; July 10, 1979 >
free of recognized hazards that may cause death or serious physical harm such as heat stress in
the following areas: SE Platform Ejector floor, LP7 Ejector floor, H7 HCP 11
2A 29 CFR 1910.1000 Employees exposed to Chloroform levels exceeding May 10, 1979. the ceiling value shown in.table Z-l in the "chem lab" area and employer failed to effectively
use feasible engineering or administrative, controls.
Progress reports must be filed with this office every 90 days during abatement.
April 10, 1979
i:
ZB 29 CFR 1910.134(a) Failure to provide and require the use of approved February 27, :.';
respirators* In accordance with the requirements
1979
of 1910.134(b) where employees are exposed to
higher than permitted levels of chloroform,
pending compliance by engineering or administrative
controls.
*See enclosed Operational Procedures Notice-2 on respirator approval.
The law requires that a copy of this citation shall be prominently posted in a conspicuous place at or near each place that
an alleged violation referred to in the citation occurred. The citation must remain posted until all alleged violations cited therein are j "
corrected, or for 3 working days*, whichever period is longer.
" '.7. -
RIGHTS OF EMPLOYEES
V= '
Any employe* or representative of employees who believes that any period of time fixed in this citation for the correction of a violation is unreasonable has the right to
contest such time for correction by filing a notice with the N. C. Departmentof Labor at the address above within 15 working days of the receipt by the employer of notice
of proposed penalty or notice that no penalty is being proposed.
- ...
`No employee shall be discharged or discriminated against because such employee has filed any complaint or instituted or caused to be instituted any proceeding or
inspection under or related to this Act or has testified or Is about to testify in such proceeding or because of the exercise by such employee on behelfof himself orothers/
of any right afforded by this Act" See 5<h) of the North Carolina Occupational Safety and Health Act of 1973.
:vt5
`Under the Occupational Safety and Health Act, tl
Acting
14. Director's Signature---------------------------- -
L.A. Weaver
rmiV/orking Day" means Mondays through Fridays but does not include Saturdays, Sundays, or State Holidays.'
. . January 10,( ; ' /7; 79
JtyyiLriMuanc* Oats1 " ~
.19--------- :
OSHA-2 -
70248
CITATION
N. C. DEPARTMENT OF LABOR
OFFICE OF OCCUPATIONAL SAFETY AND HEALTH 4 West Ed*nton Street Raleigh, N. C, 27601
3- T0: Fiber Industries, Inc. P.0. Box 4 Salisbury, N.C. 28144
- 1. SO/lTiNo. B0436
2. OSHA-1 No. . * ;r 0.07-79 . :..r^
4. Citation Number
TWO
5. Page
T - of
TYPE OF ALLEGED VIOLATION(S): Non-SerlOUS
'
September 5,6,7,8,11,12,13,14
An inspection was marli4H9uSt 22,23,24,25,28,29,30,31
Highway 7Q_Mest. Barber Junction. Salisbury. N.C. Production of Polyester Fiber
t9 78
of a place of employment located at: *
v;
and described as follows :
Item No.
On the basis of the inspection it is alleged that you have violated the North Carolina Occupational Safety and Health Act of 1973, in the following respects:
Standard, regulation or section of the Act
allegedly violated
T5T
Description of alleged violation
; Date by which re alleged violation must be corrected.';?
29 CFR 1910.1001 (h)(1)
Employer failed to maintain external surfaces; in place-of employment free of accumulations of asbestos fibers, which with" dispersion would cause an excessive concentration, such as in.K-4 West area on second floor; H7 ejector floor.
January 10,'fv, 1980
29 CFR 1910.134 (d)(2)(H)
29 CFR 1910.134(a) (2)
Failure to Install on the oil lubricated
April 10, 1979
compressors a high temperature or carbon monoxide .
alarm, or both. (If only a temperature alarm Is
" - /
used, the air from the compressor shall be
frequently tested for carbon monoxide.
Failure to establish and maintain a respiratory
M ' \ ' -
March 10, 1.979s
program which includes the requirements outlined
in 1910.134(b)*
,,
*See Operational Procedures Notice-2 on respirator approval, enclosed.
-Cv*>
.lii
'"-M
i ft
The law requires that a copy of this citation shall be prominently posted in a conspicuous place at or near each place'that^ ; alleged violation referred to in the citation occurred. The citation must remain posted until all alleged violations cited therein ara.it, erected, or for 3 working days*, whichever period is longer.
RIGHTS OF EMPLOYEES
\ny employee or representative of employees who believes that any period of time fixed in this citation for the correction of a violation Is unreasonable has the lighttpjg itesi such time for correction by filing e notice with the N. C. Department of Laborat the address above within 15 working days of therecelpt by the employerofnotice]?
oroposed penalty or notice that no penalty is being proposed.
V`
No employee shall be discharged or discriminated against because such employee has liled any complaint or instituted or caused to be instituted anypnxeedlngotw section under or related to this Act or has testified or is about to testify In such proceeding orbecause of the exercise by such employee on behalf ofhimselforotheijpsj
any right afiorded by this Act." See 5(h) of the North Carolina Occupational Safety and Health Act of 1973.
..
'* .
____
Under the Occupational Safety and Health Act. iheleim *y/orklng Day" means Mondays through Fridays but does not Include Saturdays, Sundays, orStateHofidys$
Acting
Director's Signatureu tT.Ujf1/
'MjL
------ -
January .10;
issuance Date.
.A. Weaver
QSHA-2
702485
; * . ^V`
--
. *. . ?: 'v-V./;;
' ru ..... '
..; ;..`,.5-_,' ._... .
^.^>i.afDDEEPPAARRTTMENT OF LABOR'^;^^-
w* ^`**A. .croct o0r/ OoCcCcUupPaAtTiIoOnNaAlL StxAf^iITrTr *aMnOo Mhet*aVl.TtVht :''-V '' "l
* * -..-l1*':
I WmI CdfftNA StrHt
A*W^V, X C.I7M1
'"/CITATION &*? ZTMrt*"-* : .`Tv -C-; i,-?--T
T*?V-V* -*'' .y;>:
v-V' V- "
*- '___ :--i v-C1;.- "
two ' -~ .* *'
CiUlIon Numbvf _____________________________ '
Pfli *' ~V' 1 -^--' `a. `illli-----
/>* j-v-C'v.
TYPE OF AD-EGED.VIOLATIONtSI : Non-Seri OUS'
.yy-VSeptember 5,6,7,8,11,12,13,14-'
,;
7. An;wpetioVwimdeto^t 22.23 .24 .25.128.29-^30,31 '19 78--1 ooff aa ppli>aect ooff emmcployment located at: , .
H1rS\v ?fl Y.'cf P.-rh^r Ji'nrtion. Salisbury. M.C.
Production of Polyester Fiber
-
and described at follows :
TV. tV *
i: r-.f
* r-.: *'*
^ .Oft IK# bnit o< lh lo*ction it it ><#g#d lhatyow Hv# vicUccd th# North Ctrollo# OccuoaliOAtl Slty nd HmIM Act of 1973,
t *vV/- ip th# loUo**** mocu: *
- # \y ` .
.`.'V, *':. , '
TT
y :7'' Nov
u. ~ ~r yy ;
ir`Stindird. rtgulitioo
t section of the Act. ",
'allegedly violjttd
T3T
e . . 7'. ;
-
"
'
Description of alleged violation ,.
: pi.
Date by which alleged violation ' [.
mult be corrected '
*' I .<% : .. k *
. ;f \
l\vr/ 29 CFR 1910.1GC1
(h)(1)
.
.
s^ X> r >
Employer failed to maintain external surfaces In ;->1ace of. e.rolcyment free of accuna/latlcns of asbestos fibers,.which with dispersion would cause an Excessive concentration, such as In K-4* West area on second floor; H7 ejector floor.
|January 10, ` .1930*
iT V *
2? CFR 191C.134
(C)(2)(H).
Fa 11 uI'^s to Insta'll-on the oil lubricated cccprcS^sors-a.Mgh-'temperature or. ctrbon roncxlrie alarm, "or both. (If only a temperature alarm Is used, the air from the compressor shall be . frequently..tested for. carbon monoxide.
hafc 29rCFAi1910.134(&)
N*-rfcT^ .
: A: S~
Ni.r. .?,'/ .^r vv.
--`u..'. ..
Fallurevtc'iestab'llsh `end maintain' e respiratory. program which inclucfes-'thc'rcqulreirents outlined
In isiO.'l34(b)*... J . . -
*Sec Operational Pnocedurcs .Hotlce-2 on respirator
April 10,' 1979 March .1.0, 1979:
w)
Ci
o r-
^,v*
a
*??-
V.V ?:-s *?
vs5
1
$,
1
f
m
L
*vi,lKJyr >,`v;(W| vJiOfT-/.*;5'--.-.-J'vi+;'- f .*
Wj
>. V.,^TV
* *
: ' I
2. GSHA-1 No.
.00Z-79
702445
I IW-
v'f.: '
rV:-
-:. * ->-i
..
. -TY?E OF ALLEGED VIOLATIONISK:.
Seri1oUu"Us1-.''; ................... ....................... ..
... ... , ..
*>;> -,'r'
ieuconbcr 5,6.7,8,11,72,13,-14
*\
August 22,3,24,25,22,'2S,.10,31
' '
;7. An imptction w md* on ______________
' - '19 iiL__ of > fslsca of employrntm Jocited al .................................. .
^Hlnhwav^O West:- Barber Junction^ Salisbury. II.C.'`
- " indd,,,,ibed ,, (oIlow;.
-g^v VrrcVrtfon rf. nclvpr.tor fibp-r '
' 1 :
_____
' -_______ '
* r .r*
'''.S-i")
tKc" ol lK inaction It i| ti1*9*4 that you h*v* violat*d tha North Carolina Occupational Safa tv and HaalUt Act of 1973* *
`
rTr"~;~"
i: Item r; No.
thi foilo^nfl *tio*cti: ",
U. . * * ; *: Standard** regulation * .. or lection of the Ad
allegedly violated
tr
* Description of alleged violation '
*t -
. * ."
* . . }-,
13. Oju by'which -
.* alleged violation, must be corrected
Failure to provjde employees a place of cmployiranc
free of recognlzed'hazards tint may cause death
or serious physical harm such as heat stress In
the foil a; I up areas: :
SE.Platform *
Ejector floor, LP7
'
,,
Ejector floor, H7
HCP 11
July 10, 1979
i >.. ''*.
Employees exposed to Chloroform levels exceeding ..
the ceiling value shewn in table Z-l In the
"chfcm lab" area and employer .failed to effectively
use feasible engineering or administrative ._
controls: !
. '
Progress.'rcports must be filed-with this office
May 10, 1979 /
Ftilure'EtO;provide'and require Ihe use of acproveu''. February 27. ..;i, ^ J979'.y
I
x :j: \v. *:V"->Ai
{y.y . - :
i ? } -.'Kiu
. I { S; v'.VV^r 'i
& tLpt ^
';5;rv>
[;jr|
u,.tv:-iIl
:-j..va.s' ."s J :i % -V-
: "* r.
_____ _ .
fKal."yp^od^oMlmt Oipdift \hkelUilpn'foVih eorwcilVnOl *Vbutto'nu ^wt^ih'^C.Diapa'rtMMoiLJt^it*trMaddia'|rKb4ivwithtA'15wpfHin^d'iyolihafacVipTby
-i-j .vr-K.-rA.5 i-v -^r5;
Fki j'' " 1
'mpiPrV*iNa PL'tficrvjrgC o* durmitiid flatnllbccauia luchamplpyW hai hltd ny'coimplatrt orihallluffd 0<Jtu**d iot>JnHil_uUd anyprccj'
S^lnu* i!mui2i(Wai itliiMl li?nilvA<1 whll jjTlfiiM tt' lTtt^ufla'tll'uly kilueVaAumiIIm'(Ubieauta nllhltilitclitkv kiell IflilHoVM Onb*niil Of hlmialf Of 0|'
Xfrfi.
a ; *
9
m
$
CITATION
N. C. DEPARTMENT OF LABOR
OFFICE OF OCCUPATIONAL SAFETY AND HEALTH 4 Wt CdMlM Str*l fUtelgh, N. C. 77401
3- T0: Fiber Industries, Inc. P.O. Box 4 Salisbury, N.C. 28144
1. bU, 1H NO. --- V. UihA l NO.
B0436
007-79
j
4. Citation Number
TWO
5. Page
of 6.
TYPE OF ALLEGED VIOLATIONS): Non-SerlOUS
September 5,6,7,8,11,12,13,14
7. An impeainn wat
22,23,24,25,28,29,30,31
13 ^8 of a place of employment located at:
8. Highway 70 West. Barber Junction. Salisbury. NjJLiand described as follows : g Production of Polyester Fiber____________________________________________________________
10.
Item No.
i
On th besis of the inspection it is alleged chat you have violated the North Carolina Occupational Safety and Health Act of 1973, in the following respects:
11.
Standard, regulation or section of the Act
allegedly violated
12.
Description of alleged violation
13. Date by which alleged violation
must be corrected
29 CFR 1910.1001 (h)(1)
Employer failed to maintain external surfaces In place of employment free of accumulations of asbestos fibers, which with dispersion would cause an excessive concentration, such as In K-4 West area on second floor; H7 ejector floor.
January 10, 1980
2 29 CFR 1910.134 Failure to Install on the oil lubricated
April 10, 1979
(d)(2)(H)
compressors a high temperature or carbon monoxide
alarm, or both. (If only a temperature alarm Is
used, the air from the compressor shall be
frequently tested for carbon monoxide;
3 29 CFR 1910.134(a) Failure to establish and maintain a respiratory March 10, 1979 (2) program which Includes the requirements outlined In 1910.134(b)*
*See Operational Procedures Notice-2 on respirator approval, enclosed.
The law requires that a copy of this citation shall be prominently posted in a conspicuous place at or near each place that an alleged violation referred to in the citation occurred. The citation must remain posted until all alleged violations cited therein are
corrected, or for 3 working days*, whichever period is longer.
RIGHTS OF EMPLOYEES
Any employee or representative of employees who believes that any period of time fixed in this citation for the correction of a violation is unreasonable ha the mqM to contest such time for correction by filing a notice with the N C Departmentof Labor at the address above wthm IS working days of the receipt by the employer of nonce
of proposed penalty or notice that no penalty is being proposed.
,
"No employee shall be discharged or discriminated against because such employee has filed any complaint or instituted or caused to be instituted any proceeding or
inspection under or related to this Act or has feslif/ed or is about to testify in sucn proceeding or because of the exercise by such employee on behalf of himsaif or others
of any right afforded by this Act." See 5(h) of the North Carolina Occupational Safety and Health Act of 1973.
'Under ihe Occupational Safety and Health Act. thejwm Yforking 0ay" means Mondays through Fridays but does not include Saturdays. Sundays, or Stats Holidays
Acting
January 10,
79
14 Director's Signature------------------------------------- ------------------------------------------------------------------------------ Issuance Oete-------------------- -----------------------------19---------
L.A. Weaver
OSHA-2 March 1977
ASBESTOS SAMPLE RESULTS JUNE 29, 1979
These samples were taken prior to the cleanup operation. These samples were taken at random in the CP/Spinning areas of H and'K Buildings.
JUNE 30, 1980 These samples were taken after completion of the cleanup. These samples were also taken at random in the CP/Spinning areas of H and K Buildings. Sample 3 contained <1% asbestos. Sample 3 was taken from a crack in the wall and would not constitute a violation of the housekeeping standard. Sample 7 was known to be asbestos and was used as a control.
70246C
i
I
c
waiter c. mccrone associates, inc.
CONSULTING: ULTRAMICROANALYSIS MICROSCOPY SMALL PARTICLE PROBLEMS SOLID-STATE CHEMISTRY
S
29 June 1979
Ms. Joan Wronskl National Loss Control Service Corporation Long Grove, Illinois 60049
Dear Ms. Wronskl:
We have completed our analysis for asbestos in the six bulk samples submitted with your letter of 20 June. These samples were identified as 11286-11291.
The samples were examined by polarized light microscopy and dispersion staining. The results of this examination are given in the following table:
Sample
Type asbestos
% Wt. Other fibrous material
11286 11287
11288
11289 11290 11291
none
cellulose, trace
chrysotile 10 none
amosite
50
none
" glass 60%
cellulos 10%
amosite
15 none
none none
-- polyester 50% -- polyester 80%
Thank you for consulting McCrone Associates. If there should be any questions concerning these results please call me.
Yours sincerely.
Mark Palenik Research Microscopist
MP: f e ref: 7043
702467
?i\P0 SOUTH MICHIGAN AVENUE . CHICAGO. II I iNOIS 6'JSir. . Tip A.l?.TI0O . CARLE' CHEMICRONE
NATLSCO National Loss Control Service Corporation Long Grove, IL 60049 *. 312 J 540-2488
ENVIRONMENTAL SCIENCES LABORATORY, A-1
LABORATORY ANALYSIS REPORT
To*
MR* DALE 0WEN FIBER INDUSTRIES INC. P.O. BOX 4, HIGHWAY 70 WEST SALISBURY, NORTH CAROLINA 28144
a ubtidlary ol Kemper? covouijun
REPORT DATF- 7 JULY l<?ao SAMPLES REC'Dr30 JUNe 1980 REQUEST NUMRFR; 12327
COMMENTS- METHOD; POLARIZING LIGHT MICROSCOPY WITH DISPERSION STAINING ANSWER WILL BE SENT AT A LATER DATE; SENT OUT FOR ADDITIONAL ANALYSIS.
RESPECTFULLY YOURS,
([. (jJ
JgAN A, WRONSKI, MANAGER
ENVIRONMENTAL SCIENCES LABORATORY
7024BS
ACCREDITED BY THE AMERICAN INDUSTRIAL HYGIENE ASSOCIATION
Interoffice jr> >/b. V. Perry FROM B- T- *TMZSL
FIBER INDUSTRIES, INC.
REF. NO. BTB-48-80
/
REF NO.
CATE Aug. 27, 1980
SUBJECT:
ASBESTOS HOUSEKEEPING COMPLIANCE OSHA FILE 24,648 CITATION TWO ITEM NO. 1, ASBESTOS ACCUMULATION
As a result of an OSHA citation in August, 1978, we were made aware of housekeeping problems associated with the removal of insulation con taining asbestos. It was pointed out that small quantities of this insulation had accumulated on surfaces in certain areas.
To achieve compliance a cleanup crew was established, the existing pro cedure was upgraded and the cleanup crew was trained in proper handling methods. This crew throughly cleaned floors, equipment, pipes, ducts, structural steel and other surfaces to remove possible accumulations of asbestos material. To verify the effectiveness of the cleanup, samples of debris were taken before and after cleanup and the samples Were ana lyzed for the presence of asbestos. Results of these samples are attached. Labor expenditures of $44,482 and material cost of $5,742 were required to complete the cleanup.
The following areas were cleaned:
1. Glycol Recovery Unit 2. Dowtherm Yard Areas (H & K Bldg.) 3. Boilers House (T Bldg.) 4. Continuous Polymerization Areas (1st, 2nd and 3rd floors in both
H & K Bldg.) 5. Spin Draw Area (1st floor & 1st Floor Mezz., K Bldg.) 6. Staple Spinning Area (1st Floor Mezz, H Bldg.) 7. Staple Processing Area (1st Floor & 1st Floor Mezz, J Bldg.)
With completion of the cleanup and with analyses of samples showing no remaining asbestos accumulation, we are now in compliance with the housekeeping section of the OSHA asbestos standard (29 CFR 1910-1001(h)
CD)
79246j
BTB:pem Attachment
FIO-69
cc: C. E. Brown H. E. LeGrand
B. T. Bowyef
i '
:*-H\
.. < . * . . .. _ ___ _ ___. _ _
1. SO/L*/o.:
2. OSHA-1 No..'
. J. . `
>' ' CQ7-79 >
. '
.`{''T'-.-yl'Slbcr Induataioa,*
' cifica Box 4
; :Tv
...., -J.. 1>.;V
-IT-,.--:-------^ of
--------
. . V-
...............
: *
* /
.
*..'** *
.
type ofalUged violatiqnisi . Ifaiv-Serlcua s
ryyjr^i
'
...... ,- - : V; 7.-An Irapection wu mid* on -&&
5,6,7,6,11,12,13,14 and 23t 24)^5* 28* 2930t31>
-
. . ig
_7__ %
' >*
-* 'J.
of.,
p|4Ct
0f
*'
employment
locate.d*;a' tv: ^*;
'*;?
BLffra-s 70 Uest,' BuAaer-Junctlan, -Sallataay, Hortfa-CaroLlm
^d`tiefftid*11-^ov^.;
protection of polynatar fiber >;
`
.......
. ' .V.
Deieription'of allaged violation
THE ABOVE CITATION NUMBER. ISSUED. AMENOED AS-SET FORTH BELOW. THIS CITATION 13 AMENOED TO EXTEND THE ABATEMENT DATE ONLY.
v.*
TT" Dut by whiijh
. alleged violation . must be corrected
Kay 31-, .1979 . V
..r-.-T,1
'.. a- 7 .-^Jv
: -r->
Vi
----
v- ,,
-----------
'---* xr kABWfl
W ,J
. r'V ,4.. - . - *OeeFup0*oBnogl 1SU.l,,.ly _anRd,,H,,agahlthNAdcmlnlalrsUan .
rV)-0 vii'y!..'. ** " '*
* ----
, y T
'CITATION
\C~
J'-'iS
11. J- -- *.'1
"'Q
~~a^7537 *. css" Vj%
Aind-- Feaaral Region-'Federal
yjo
04 .fl
*f>070
County
159
Stale Aros
s
03
**a
Fiber Industries, Inc.
%.
. PaO. Sox 4 '
-.Salisbury,- North Carolina -'28144
3. Citation Number.
4. Page.
-of 5. .
TYPE OF ALLEGED VIOLATION(S):' Non-serious
- - 7.
An inspection was made on Harch 17-21,
19 73 ot a place of employment located at:
' l . Hlchvav U.S. 70 t'est. Salisbury. H.C.
____________________________ and described as follows:
* Manufactures polyester staple nnd flllccnt yarn
On the basil of the impeclinn it b alleged that you have violated the North Carolina Occupational Safety and Health Act of 197). in Ihc followtnf respects:
SljnJard, refutation oi section of the Act
lllcjtcJly violated
14
Dcivriplinn nf altc,eii viuOtiun
U. Date Ity wtiiili
aHcptfJ viuljifuit
muit Uc OWfcvIcil
CfH 1910.232(c)(2) Failure to separate oxygen cnJ fuel pan cyl ludcm
(lv)
In central and draw feutae ciaintcnancu
it
minimal distance of twenty feet or by a non-
cotabustlblc barrier at lease five feet !ii;*l>.
Ir.inii'it.irel y Upon Receipt Of Citation
Cfrt 1910.217(c)(1) Failure to provide |>olnt of operation guarding or device for punch press 'la central chop.
Ioivc.il.it cl y Upon i.cceipt: Of Cir.,.rlou
29 CFR 1910.213(h)
Failure to provide blade guard for looor portion
of blade on radial caw in carpenter ihop, ami
failure to Install the cutting head so that It
will automatically return.to the starting post Clot
when relcAscd'liy the operator. `^29 CFR 1910.213(J)(4)
No guard provided for section of cutting horn! behind fence on Rockwell Jointer in carpenter shop.
CyT. 1910.219(e)
No guard provided for V-belt drive on vacuum pu.in end adequate guard not'provided for V-bolt drive 'on brldgoport drill press In central' chop.
Itn'utdi.iUe.l y Upon Ucc.-lpt Of vUcntion'
Tt.mcdiitccly Upon Receipt
>Of vUtulluti
May 9, 1973
'\
' iL*t
-5 nr<> 1,
C*5 ' [a?
{Ca5? -CV<
&
Failure to provide suitable facilities for quick
drenching of the eye's anri'-body for employees that
handle sodium hydroxide In utility building
boiler room. - '
''
29. CFli 1910.232(a)(2) No welding scroons provided for welding ntatlon
in fiimaent .boom maintenance shop.
..l-.'-i ";>
' ''
Hay 9, 1973
Ii.incdiiir.oly Upon Receipt Of Citation
I'^'ij^p.vTha^UWrtqulres tha't a copyjof this d'tatlon shall be prominently posted In'a conspicuous place at or near 1 il'each place tha_t an.allegedsvlolstlon'referred'to'ln the citation Occurred. The elution must remain posted until all
alleged violations cited therein are doneeted>or for 3 working days*, whichever period Is longer.
T7! ~ ~
. ~ T
tmploytt'or.rtprneitllllvt of amploytiTwho believti'lhal any period of time flxd In ihii citation for .the correction'of violation U tin-
I'-oMHb^klr hailhc ri*hl lo'tonl'ni such lime forwrrectlon by filing a noIke with the. N.C Department of I ahoe at the addiesi sh.i.n above ith-
fUnjdayi of *h`c receipt ty'tiu employer #f notice of propoicU penalty crnoikt that no penally h king prnpid.
` -- av.u ka.
-a.
s^i ...u.t
--k------ r.t. i ....------------------- Vm 0(. |m,i)ulcii or earned to he Imtitutcd
iKfling or became`Of the exm< by uehv Occupational Safety anil Health Act of WJ.
de ool include Saturdays Sunday*,
- on r owiiiniMiieiwi s.SIgnilurel.__________
iir listingppr- liavcli 27,----------- j0 _Zi_ -'- I
* fl.T^awwyaaVawJ!oTa^^KraWMa.T.Tara^.TaiT*>Ti*.n.Xi.Ta3QdaasK*30mo^^
^'a;jj^/ooy'^^^^^^f^j5^?/--:iNOT|CVAddlilonsrirrip<)f'ts'nt'l"nformaiion
On
B lo.o...
Rev'srss Skis)'
.' ' .
...
Form ObVtA.f Juno 1077
m
sN>-*.
*V;'-
v-f.
702443