Document 9176eLvDNNxpmkRaY0GVm1eDD

w]^rr JM Asbestos inc Chrysotile XI02- Head oTtice. suite 750 Jeffrey Mine JtXZ. 2000 Peel Street Asbestos. Quebec J1T3N2 Montreal. Quebec H3A 3W5 Canada Canada (819)879-5431 (514) 288-5917 PLAINTIFF'S Asbestos Fiber EXHIBIT Material Safety Data Sheet GH-203 PRODUCT IDENTIFICATION JM Asbestos Inc. Asbestos, Quebec, Canada JIT 3N2 Emergency Telephone N. (819) 879-5433 Chemical Name & Synonyms: Chrysotile Asbestos Trade Name & Synonyms: Asbestos Chemical Family: Fibrous Mineral Silicates Formula: Mg3 (Si205) (OH)4 CAS Registry Number: 1332-21-4 EPA Code Designation: A152-4672 HAZARDOUS INGREDIENTS Paints, Preservatives & Solvents Pigments. Catalyst. Vehicle. Solvents. Additives and Others Alloys and Metallic Coatings Base Metal. Alloys. Metallic Coatings. Filler Metal plus Coating or Core Flux. Others Hazardous Mixtures of Other Liquids. Solids or Gases Chrysotile Asbestos Fiber Approx I00/o (For TLV -- See Section V) TLV (Units) NA N. A PHYSICAL DATA Boiling Point ( F). Vapor Pressure (mm Hg ) Vapor Density (Air -- 1). Solubility in Water Appearance and Odor White Fibrous dry material--no odor Specific Gravity (H2O-I) Percent volatile by volume (%) Evaporation rate N/A N/A 24-2.6 N'A N/A FIRE AND EXPLOSION HAZARD DATA Material is non-flammable. No fire or explosion hazard. V health hazard data Threshold Limit Value OSHA Exposure Limits Effective July 1, 1976. The 8-hour time-weighted average airborne concentrations of asbestos fibers to which any employee may be exposed shall not exceed two fibers, longer than 5 micrometers, per cubic centimeter of air. Ceiling Concentrations. No employee shall be exposed at any time to airborne concentrations of asbestos fibers in excess of 10 fibers, longer than 5 micrometers, per cubic centimeter of air. [Refer to OSHA Standard for Exposure to Dust. 29 CFR 1910. 1001 paragraphs (b)(2) (b)(3).] Emergency and First Aid Procedures Avoid breathing excessive dust when handling, dumping and mixing. See caution label on bag. VI REACTIVITY DATA Stability Incompatability (materials to avoid) Hazardous Decomposition Products Hazardous Polymerization Stable N/A None Will not occur SPILL OR LEAK PROCEDURES Steps to be taken in case material is released or spilled Vacuum clean spillage. Repair broken bags. If sweeping is necessary, wet down spillage. Use approved respiratory equipment when required. Waste Disposal Method Disposal ol waste in accordance with OSHA Standard for Exposure to Asbestos Dust. 29 CFR 1910 1001 and EPA National Emission Standards for Hazardous Air Pollutants 40 CFR 61. VIII SPECIAL PROTECTION INFORMATION Respiratory Protection Use respirators as recommended by the OSHA Standard for Exposure to Asbestos Dust. 29 CFR 1910. 1001 paragraph (d). Ventilation Control with mechanical dust collection equipment to within TLV (See American National Standards Institute booklet. Z9.2--1971). Other Protective Equipment Use special clothing as required by the OSHA Standard for Exposure to Asbestos Dust. 29 CFR 1910. 1001 paragraph (d). IX SPECIAL PRECAUTIONS Precautions to be taken in handling and storing Maintain good housekeeping practices. Vacuum clean waste and place in closed containers. Other precautions CAUTION LABEL ON BAG: Contains Asbestos Fibers--Avoid Creating Dust--Breathing Asbestos Dust May Cause Serious Bodily Harm Smoking greatly increases the risk of serious bodily harm. JM-301 8/85 MANUFACTURER'S NAME DATE OF PREPARATION 18 October 1985 MATERIAL SAFETY DATA SHEET ` X'io Ca-KEY CANADA INC P 0 Box 190 East Broughton Station, PQ Canada G0N 1H0 EMERGENCY TELEPHONE NO (418) 426-3050 INFORMATION TELEPHONE NO (418) 426-3050 - SECTION I - PRODUCT IDENTIFICATION PRODUCT NUMBER Various Grades PRODUCT NAME Chrvsotile Asbestos (this MSDS applies to all grades) PRODUCT CLASS Fibrous Hydrated Magnesium Silicate ' INGREDIENT PERCENT SECTION II - HAZARDOUS INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS' PEL TLV VAPOR PRESSO Asbestos (list percent) Chrysotile Asbestos C.A.S. #12001-29-5 I. Shipping Number 2590 (white asbestos) 2 fibers/cc- 8 hr. TWA Ceiling Concentration 10 fibers/cc OSHA Standard at 29 cFk 1910.1001 Chrysotile - 2.0 fibers/cc . ACGIH, Documentation of TLVs at 27 Fibers measured are those longer than 5 microns. N.A. H. M. I. S. rating numbers (optional) Health: * (Possible Chronic Effects) Flarmability: 0 Reactivity: 0 [Optional statement: Contains WT% Encapsulated (or Locked-In) Asbestos. Encapsula tion (or Locking In) prevents the generation of airborne fibers. No risks of hazard fran encapsulated (or locked-in) asbestos has been established.] SECTION III - PHYSICAL DATA BOILING RANGE jj.A. EVAPORATION RATE FASTER WT/GAL Variable VAPOR DENSITYN.A. HEAVIER LIGHTER THAN AIR SLOWER THAN ETHEIfc.A* VOLATILE VOLUME N.A. .......................................................................................................................................................................... --------` FLAMMABILITY CLASSIF1C ION OSHA N.A. FLAi... POINT (Non-flanmable) ____ N.A. N`A' . LEL NA` rXTINGU1SHING MEDIA: Use that which is appropriate for surrounding fire. FOAM' "ALCOHOL" FOAM C02 DRY CHEMICAL WATER FOG . UNUSUAL FIRE AND EXPLOSION HAZARDS OTH NONE SPECIAL FIREFIGHTING PROCEDURES NONE SECTION V - HEALTH HAZARD DATA EFFECT6 OF OVEREXPOSURE Acute: May cause eye and/or skin irritation. Chronic: Overexposure to asbestos can cause asbestos is, a scarring of the lungs. Pleural thickening, effusion, and plaques are nondisabling conditions, seen separately or together, that have been associated with asbestos exposure. The International Agency for Research on Cancer (IARC) has determined that there is sufficient evidence for the carcinogenicity of asbestos in humans. SIGNS AND SYMPTOMS OF OVEREXPOSURE: Asbestosis is associated with synptams of labored breathing, chest pain, weakness and chest tightness. Symptoms are not usually manifest until 15-20 years after exposure. PRIMARY ROUTE(S) OF ENTRY: DERMAL INHALATION INGESTION EMERGENCY AND FIRST AID PROCEDURES Remove asbestos slivers frcm skin promptly. In case of eye irritation, gently rinse with water. If irritation persists, get medical help. SECTION VI - REACTIVITY DATA STABILITY UNSTABLE STABLE HAZARDOUS POLYMERIZATION MAY OCCUR WILL NOT OCCUR HAZARDOUS DECOMPOSITION PRODUCTS NONE CONDITIONS TO AVOID - Avoid creating and breathing dust. INCOMPATIBILITY (MATERIALS TO AVOID) - None r "*1011 VI1 - SPILL OR LRA7 ROCCDURRS STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED Avoid creating dust. Collect dust by HEPA vacuum or in the wet state (wet sweeping, wet wiping) to prevent the emission of airborne fibers. WASTE DISPOSAL METHOD - Found at 40 CFR: (1.152 Standard for waste disposal for manufacturing demolition, renovation, spraying, and fabricating operations. Each owner or operator of any source covered under the provisions of li 61.144 and 61.149 shall: (a) Deposit all asbestos-containing waste material at waste disposal sites operated in accordance with the provi sions of | 61.156; and (b) Discharge no visible emissions to the outside air during the collection, processing (including incineration), packaging, transporting, or deposition of any asbestos-containing waste mate rial generated by the source, or use one of the disposal methods specified in paragraphs (b)(1). (2), or (3) of this section, as follows: <1) Treat asbestos-containing waste material with water: (1) Mix asbestos waste from control devices with water to form a 6lurry. adequately wet other asbestos-contain ing waste material; and (li) Discharge no visible emissions to the outside air from collection, mixing, and wetting operations, or use the methods specified by } 61.154 to clean emissions containing particulate asbes tos material before they escape to. or are vented to. the outside air; and (lii) After wetting, seal all asbestoscontaining waste material in leak-tight containers while wet; and <iv) Label the containers specified in paragraph (bKl)Uii) as follows I 61.156 Active waste disposal sites. To be an acceptable site for disposal of asbestos-containing waste material under |{ 61.151 and 61.152, an active waste disposal site must meet the re quirements of this section. (a) Either there must be no visible emissions to the outside air from any active waste disposal site where asbes tos-containing waste material has been deposited, or the requirements of paragraph (c) or (d) of this section must be met. (b) Unless a natural barrier ade quately deters access by the general public, either warning signs and fenc ing musl be installed and maintained as follows, or the requirements of paragraph (c)(1) of this section must be met. (1) Warning signs must be displayed at all entrances and at intervals of 100 m (330 ft) or less along the property line of the site or along the perimeter of the sections of the site where asbestos-conlaininE waste material is depos ited. The warning signs must: (l) Be posted in such a manner and location that a person can easily read the legend, and (il) Conform to the requirements of 51 cm x 36 cm (20 x 14") upright format signs specified in 29 CFR' 1910.145(d)(4) and this paragraph; and (lii) Display the following legend in: the lower panel with letter sizes and styles of a visibility at least equal to those specified in this paragraph. CAUTION Contains Asbestos- Avoid Opening or Breaking Container Breathing Asbestos Is Hazardous to Your Health Alternatively, use warning labels specified by Occupational Safety and Health Standards of the Department of Labor. Occupational Safety and Health Administration (OSHA) under 29 CFR 1910.1001(g)(2)(ii). (2) Process asbestos-containing waste material into nonfriable forms: (i) Form all asbestos-containing waste materia] into nonfriable pellets or other shapes: and (ii) Discharge no visible emissions to the outside air from collection and processing operations, or use the methods specified by {61.154 to clean emissions containing particulate asbes tos material before they escape to, or are vented to, the outside air. (3) Use an alternative disposal method that has received prior ap proval by the Administrator. 149 FR 13661. Apr 5. IPBt 49 FR 25453. June 21. 1684] L*9n0 NolAbOn Aabvrtot Wisit Qwpou' Sm Do hot Ouii Dual_________ SrMtfvng ASb#lO Hjtfrdoufc 10 Yo*s HMllh 2.S cm (i tncM) Sim Saril. Govtc O' Block V9 cm (V ncti) Sam Sam. Gotrvc or Block 14 Pc*Hl GotNC Spacing between any two lines must be at least equal to the height ol the upper of the two lines. (2) The perimeter of the disposal site must be fenced in a manner ade quate to deter access by the general public. (3) Upon request and supply of ap propnate information, the Administra tor will determine whether a fence or a natural barrier adequately deters access by the general public. (c) Rather than meet the no visible emission requirement of paragraph (a) of this section, an active waste dlspos al site would be an acceptable site if at the end of each operating day, or at least once every 24-hour period while the site is in continuous operation, the asbestos-containing waste material which was deposited at the site during the operating day or previous 24-hour period is covered with either. (1) At least 15 centimeters (6 inches) of compacted nonasbestos-containing material, or (2) A resinous or petroleum-based dust suppression agent that effectively binds dust and controls wind erosion This agent must be used as recom mended for the particular dust by the manufacturer of the dust suppression agent. Other equally effective dust suppression agents may be used upon prior approval by the Administrator. For purposes of this paragraph, waste crankcase oil is not considered a dust suppression agent. (d> Rather than meet the no visible emission requirement of paragraph (a) of this section, an active waste dispos al site would be an acceptable site if an alternative control method for emissions that has received prior ap proval by the Administrator is used. (Secs. 112 and 301(a) of the Clean Air Act ar amended (42 DS C. 2412. 2601(a)) SECT 10 71IX - SAFE HANDLING AND X INFORMATION RESPIRATORY PROTECTION Reusable or single use air purifying respirator - for exposures which do not uxoeedthe PEL by more than 10X Powered air purifying respirator - for exposures more than 10X, but less than 100X, the PEL ' Type "C" continuous flow or pressure-demand, supplied-air respirator - for exposures more than 100X the PEL. - All respirators must be NIOSH approved. VENTILATION Local ventilation if engineering controls are inadequate. PROTECTIVE GLOVES See "Other Protective Equipment" EYE PROTECTION See "Other Protective Equipment" OTHER PROTECTIVE EQUIPMENT If the ceiling concentration limit is exceeded, clothing providing whole body covering shall be supplied and its use required. ' HYGIENIC PRACTICES: , Do not create or breathe dust Do not dry sweep or use air hose for cleaning. Do not take protective equipment or clothing heme. SECTION IX - SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING Use nc hooks in loading and unloading. Protect containers frem damage. Do not open containers in a manner that can release dust without providing proper enclosure or control measures. Use dust supression control measures, such as ventilation or vet-working, at all stages of asbestos handling, use and disposal. Follow good housekeeping practices, such as wet-wiping dusty surfaces, to prevent accumulation of asbestos-containing dust. Avoid inhalation of asbestos. OTHER PRECAUTIONS Smoking greatly increases risk to health. IK1/ ,V V' MANUFACTURER'S NAME I/aTE OF PREPARATION 18 October 1985 MATERIAL SAPXTT DATA SHEET ' A / ^ j5 CaaEY CANADA INC P 0 Box 190 ' K to EMERGENCY TELEPHONE NO. East Broughton Station, PQ (418) 426-3050 Canada GON 1H0 INFORMATION TELEPHONE NO. (418) 426-3050 - SECTION I - PRODUCT IDENTIFICATION PRODUCT NUMBER Various Grades PRODUCT NAME Chrvsotile Asbestos (this MSDS applies to all grades) PRODUCT CLASS Fibrous Hydrated Magnesium Silicate INGREDIENT PERCENT SECTION II - HAZARDOUS INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS' PEL TLV VAPOR PRBSS0 Asbestos (list percent) Chrysotile Asbestos C.A.S. #12001-29-5 Shipping Number 2590 (white asbestos) 2 fibers/cc- 8 hr. TWA Ceiling Concentration 10 fibers/cc QSHA Standard at 29 CFR 1910.1001 Chrysotile - 2.0 fibers/cc ACGIH, Documentation of TLVs at 27 Fibers measured are those longer than 5 microns. N.A. H. M. I. S. rating numbers (optional) Health: * (Possible Chronic Effects) Flanmability: 0 Reactivity: 0 [Optional statement: Contains ____ WT% Encapsulated (or Locked-In) Asbestos. Encapsula tion (or locking In) prevents the generation of airborne fibers. No risks of hazard frcm encapsulated (or locked-in) asbestos has been established.] SECTION III - PHYSICAL DATA BOILING RANGE jj.a. EVAPORATION RATE FASTER WT/GAL _ Variable VAPOR DENSITYN-A. HEAVIER LIGHTER THAN AIR SLOWER THAN ETHERj.aI VOLATILE VOLUME N.A. WM'* ' ****** lk>A4 WVW * Vit rtAftAlW |\ >^ / -, / .................................................................................................................... ............................... AJCQ2/S.. FLAMMABILITY CLASSIFIC. .ON OSHA N-A- FLAS.. POINT N*A* LEL NA' (Non-flannable) ----- fcLA____ P.XT1NGU1SHING MEDIA: Use that which is appropriate for surrounding fire. FOAM "ALCOHOL" FOAM C02 DRY CHEMICAL WATER FOG UNUSUAL FIRE AND EXPLOSION HAZARDS OTHE NONE SPECIAL FIREFIGHTING PROCEDURES NONE SECTION V - HEALTH HAZARD DATA EFFECT6 OF OVEREXPOSURE Acute: May cause eye and/or skin irritation. Chronic: Overexposure to asbestos can cause asbestos is, a scarring of the lungs. Pleural thickening, effusion, and plagues are nondisabling conditions, seen separately or together, that have been associated with asbestos exposure. The International Agency for Research on Cancer (IARC) has determined that there is sufficient evidence for the carcinogenicity of asbestos in humans. SIQ'JS AND SYMPTOMS OF OVEREXPOSURE: Asbestosis is associated with symptoms of labored breathing, chest . pain, weakness and chest tightness. Symptoms are not usually manifest until 15-20 years after exposure. PRIMARY ROUTE(S) OF ENTRY: DERMAL INHALATION INGESTION EMERGENCY AND FIRST AID PROCEDURES Remove asbestos slivers from skin promptly. In case of eye irritation, gently rinse with water. If irritation persists, get medical help. SECTION VI - REACTIVITY DATA STABILITY UNSTABLE STABLE HAZARDOUS POLYMERIZATION MAY OCCUR WILL NOT OCCUR HAZARDOUS DECOMPOSITION PRODUCTS NONE CONDITIONS TO AVOID - Avoid creating and breathing dust. INCOMPATIBILITY (MATERIALS TO AVOID) - None ~TVoii VIi - spiuTSTTSa7' 'ROCIOORK y STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED Avoid creating dust. Collect dust by HEPA vacuum or in the wet state (wet sweeping, wet wiping) to prevent the emission of airborne fibers. WASTE DISPOSAL METHOD - Found at 40 CFR: 161.152 Standard for waste disposal for manufacturing demolition, renovation, spraying, and fabricating operations. Each owner or operator of any source covered under the provisions of ii 61.144 and 61.149 shall: (a) Deposit all asbestos-containing waste material at waste disposal sites operated in accordance with the provi sions of f 61.156; and (b) Discharge no visible emissions to the outside air during the collection, processing (including incineration), packaging, transporting, or deposition of any asbestos-containing waste mate rial generated by the source, or use one of the disposal methods specified in paragraphs (b)(1), (2). or (3) of this section, as follows: O) Treat asbestos-containing waste materia] with water: (1) Mix asbestos waste from control devices with water to form a slurry; adequately wet other asbestos-contain ing waste material; and (li) Discharge no visible emissions to the outside air from collection, mixing, and wetting operations, or use the methods specified by ( 61.154 to clean emissions containing particulate asbes tos material before they escape to, or are vented to. the outside air; and (iii) After wetting, seal all asbestoscontaining waste material in leak-tight containers while wet; and (iv> Label the containers specified in paragraph (bXIXiii) as follows: CAUTION Contains Asbestos Avold Opening or Breaking Container Breathing Asbestos is Hazardous to Your Health Alternatively, use warning labels specified by Occupational Safety and Health Standards of the Department of Labor, Occupational Safety and Health Administration (OSHA) under 29 CFR 1910.1001(g)(2)(ii). (2) Process asbestos-containing waste material into nonfriable forms: (i) Form all asbestos-containing waste material into nonfriable pellets or other shapes; and (ii) Discharge no visible emissions to the outside air from collection and processing operations, or use the methods specified by i 61.154 to clean emissions containing particulate asbes tos material before they escape to. or are vented to, the outside air. (3) _ Use an alternative disposal method that has received prior ap proval by the Administrator. 149 FR 13661. Apr 5. 1964 49 FR 25453. June 21. 1964) I 61.156 Active waste disposal sites. To be an acceptable site for disposal of asbestos-containing waste material under || 61.151 and 61.152, an active waste disposal site must meet the re quirements of this section. (a) Either there must be no visible emissions to the outside air from any active waste disposal site where asbes tos-containing waste material has been deposited, or the requirements of paragraph (c) or (d) of this section must be met. (b) Unless a natural barrier ade quately deters access by the general public, either warning signs and fenc ing must be installed and maintained as follows, or the requirements of paragraph (c)(1) of this section must be met. (1; Warning signs must be displayed at all entrances and at Intervals of 100 m (330 ft) or less along the property line oi the site or along the perimeter of the sections of the site where asbes tos-containing waste material is depos ited. The warning signs must: (i) Be posted in such a manner and location that a person can easily read the legend, and (ii) Conform to the requirements of 51 cm x 36 cm (20 x 14") upright format signs specified in 29 CFR \ 1910.145(d)(4) and this paragraph; and (Hi) Display the following legend in : the lower panel with letter sizes and styles of a visibility at least equal to those specified in this paragraph. t*9nd NoUbon Aaoaciot Dapoui Sn* Do Noi Omi Dual_________ SrMtrvng Aabaatot a Hurdout to Vot/ HaiWi 25 cm (t Inch) Sana Sant. Gothc or Btock 1.9 cm vKfi) Sans Sant. Gothic O' Bk>CA 14 Point GoOvc Spacing between any two lines must be at least equal to the height of the upper of the two lines. (2) The perimeter of the disposal site must be fenced in a manner ade quate to deter access by the general public. (3) Upon request and supply of ap propriate information, the Administra tor will determine whether a fence or a natural barrier adequately deters access by the genera) public. tc) Rather than meet the no visible emission requirement of paragraph (a) of this section, an active waste dlspos al site would be an acceptable site 11 at the end of each operating'day. or at least once every 24-hour period while the site is in continuous operation, the asbestos-cont&lnlng waste material which was deposited at the site during the operating day or previous 24-hour period is covered with either. (1) At least 15 centimeters (6 Inches) of compacted nonasbestos-containing material, or (2) A resinous or petroleum-based dust suppression agent that effectively binds dust and controls wind erosion This agent must be used as recom mended for the particular dust by the manufacturer of the dust suppression agent. Other equally effective dust suppression agents may be used upon prior approval by the Administrator. For purposes of this paragraph, waste crankcase oil is not considered a dust suppression agent. (d) Rather than meet the no visible emission requirement of paragraph (a) of this section, an active waste dispos al site would be an acceptable site if an alternative control method for emissions that has received prior ap proval by the Administrator is used. (Secs. 112 and 301(a) of the Clean Air Act as amended (42 TJB.C. 1412.1601(a)) -* SECT I O' '111 - BKTK HANDLING AND y - /03 t INFORMATION RESPIRATORY PROTECTION Reusable or single use air purifying respirator - for exposures which do not jxoeed the PEL by more than 10X Powered air purifying respirator - for exposures more than 10X, but less than 100X, the PEL ' Type "C" continuous flcv or pressure -denand, supplied-air respirator - for exposures more than 100X the PEL. . All respirators mist be NIOSH approved. VENTILATION Local ventilation if engineering controls are inadequate. PROTECTIVE GLOVES See "Other Protective Equipment" EYE PROTECTION See "Other Protective Equipment" OTHER PROTECTIVE EQUIPMENT If the ceiling concentration limit is exceeded, clothing providing Whole body covering shall be supplied and its `use required. ' HYGIENIC PRACTICES: - Do not create or breathe dust Do not dry sweep or use air hose for cleaning. Do not take protective equipment or clothing here. SBCTION IX - SPBCIAL PRBCAOTIONS PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING Use nc hooks in loading and unloading. Protect containers frctn damage. Do not open containers in a manner that can release dust without providing proper enclosure or control measures. Use dust supression control measures, such as ventilation or wet-working, at all stages of asbestos handling, use and disposal. Follow good housekeeping practices, such as wet-wiping dusty surfaces, to prevent accumulation of asbestos-containing dust. Avoid inhalation of asbestos. OTHER PRECAUTIONS Smoking greatly increases risk to health. JM Asbestos inc At'-// / j U' / JM Asbestos Inc Head office suite 750 2000 Peel Street Montreal. Quebec H3A 3W5 (514) 288-5917 Jeffrey Mine Asbestos. Quebec JIT 3N2 (819) 879-5431 Chrysotile Asbestos Fiber Material Safety Data Sheet D JM Asbestos Inc. Asbestos, Quebec, Canada J1T3N2 Emergency Telephone No: (819) 879-5433 -- (800) 567-2700 oherrucai Name byncnyms: Chrysotile Asbestos Trade Name & Synonyms Asbestos Chemical Family: Fibrous Mineral Silicates Formula: Mg3 (Si?0s) (OH)< M HAZARDOUS INGREDIENTS Paints, Preservatives & Solvents Pigments, Catalyst, Vehicle. Solvents. Additives and Others Alloys and Metallic Coatings Base Metal, Alloys. Metallic Coatings, Filler Metal plus Coating or Core Flux, Others Hazardous Mixtures of Other Liquids, Solids or Gases Chrysotile Asbestos Fiber Approx. 100% (For TLV--See Section V) TLV (Units) N/A N/A PHYSICAL DATA Boiling Point (F). Vapor Pressure (mm Hg.) Vapor Density (Air = 1), Solubility in Water Appearance and Odor: White Fibrous dry material--no odor Specific Gravity (H20 = 1) Percent volatile by volume (%) Evaporation rate ( =1) N/A N/A 24-2.6 N/A N/A FIRE AND EXPLOSION HAZARD DATA Material is non-flammable. No fire or explosion hazard. HEALTH HAZARD DATA Threshold Limit Value OSHA Exposure Limits Effective July 1, 1976. The 8-hour time-weighted average airborne concentrations of asbestos fibers to which any employee may be exposed shall not exceed two fibers, longer than 5 micrometers, per cubic centimeter of air. Ceiling Concentrations. No employee shall be exposed at any time to airborne concentrations of asbestos fibers in excess of 10 fibers, longer than 5 micrometers, per cubic centimeter of air. [Refer to OSHA Standard for Exposure to Asbestos Dust, 29 CFR 1910. 1001 paragraphs (b)(2) and (b)(3).] Emergency and First Aid Procedures Avoid breathing excessive dust when handling, dumping and mixing. See caution label on bag. VI REACTIVITY DATA Stability Incompatability (materials to avoid) Hazardous Decomposition Products Hazardous Polymerization Stable ` N/A None Will not occur SPILL OR LEAK PROCEDURE Steps to be taken in case material is^gdleased or spilled Vacuum clean spillage. Repair broken bags. If sweeping is necessary, wet downtspillage. Use approved respiratory equipment wnj^n required. Waste Disposal Method Disposal of waste in accordance with OSHA Standard for Exposure to Asbestos Dust, 29 CFR 1910. 1001 and EPA National Emission Standards for Hazardous Air Pollutants 40 CFR 61. VIII SPECIAL PROTECTION INFORMATION Respiratory Protection Use respirators as recommended by the OSHA Standard for Exposure to Asbestos Dust, 29 CFR 1910. 1001 paragraph (d). Ventilation Control with mechanical dust collection equipment to within TLV. (See American National Standards Institute booklet. Z9.2--1971). Other Protective Equipment Use special clothing as required by the OSHA Standard for Exposure to Asbestos Dust, 29 CFR 1910. 1001 paragraph (d). IX SPECIAL PRECAUTIONS Precautions to be taken in handling and storing Maintain good housekeeping practices. Vacuum clean waste and place in closed containers. Other precautions CAUTION LABEL ON BAG: Contains Asbestos Fibers--Avoid Creating Dust--Breathing Asbestos Dust May Cause Serious Bodily Harm. Smoking greatly increases the risk of serious bodily harm. White the information end recommendations set forth herein are believed to be accurate as of the date hereof JM Asbestos MAKES NO WARRANTY WITH RESPECT THERETO AND DISCLAIMS ALL LIABILITY FROM RELIANCE THEREON