Document 914gdVbzpjaNKvjwKdVKG70we

Am. Ind. Hyg. Assoc. J. 50(4):216-223 (1989) NP. A Method for Monitoring Dermal Exposure to Volatile Chemicals BEN-SION M. COHEN' and WILLIAM POPENDORFB `Teledyne McCormick Selph, 3601 Union Road, P.O. Box 6, Hollister, CA 95024-0006;and &rhe University of Iowa, Iowa City, IA 5224: Absorptivepads of charcoalcloth were developed and tested for monitoringthe deposition of volatile toxic materialson skin. Thedosimlm can retain over 60%of volatile deposits such as toluene or dichloropropenedroplets over an 8-hr workday. Evaporationfrom liquid deand vapor adsorption onto the dosimeters are factors which can complicate the interpretationof exposure d8ta. Evaporation was i n v w proportional to the log of the deposit size (volume), vapor pressure, and the air humidity. Vapor adsorption was proportional to the W8p concentration, exposure duration, and the log of air velocity. A procedure is offered for estimating the initial size of the liquid deposit fmr retained mass. The charcoal cloth dosimeter's accuracy and precision are optimal in situations involving possible dermal exposure to IOU materials with low to moderate volatility or with low vapor concentration, Le., those where dermal exposure may be equal to or man significant than respiratory exposure. Introduction The human skin is known to be variable permeable to mis- cellaneous toxic chemicals which are present in the work- place."-5'For instance, a large number of mostly low volatil- ity substances, such as organophosphate pesticide^,'^"^^' enter the body primarily through the skin. The dermal route also can play an important role even for volatile chemicals, especially in a well ventilated workplace. In order to fully assess chemical exposure in such cases, one should evaluate the dermal exposure as well as the more traditional airborne exposure. Partly because of the historic emphasis of industrial hygiene on exposure via the respiratory route, the quantitive evaluation of such dermal exposures is poorly developed. Direct evaluation of dermal exposure usually is far more complicated than that of the respiratory exposure. The main difficulties arise from the variability in deposition rates onto the body, the effect of clothing, the duration of actual skin contact with the chemical, and the importance of time in the retention and permeation of the chemical through the skin. Toxic materials may reach the skin as an aerosol (fallout of mist or soluble powder), spray (ballistic droplets versus mist), or via immersion, contact with contaminated surfaces (e.g., tools or rags), or permeation through clothing (protective or otherwise). Distribution patterns of the deposited liquids over the skin in each case will be different, thus complicating quantitative evaluation. Nevertheless, several direct methods for monitoring dermal exposure have been developed since the early sixties, such as dermal dosimeters or patches,(") hand or skin the fluorescent tracer,'"' and the fiber optics luminescence skin monitor."" Since volatile materials tend to disappear from surfaces rather quickly, the above methods in their present state of development will not be suitable for monitoring volatile dermal deposits. For instance, it was shown that even depos- its of relatively low volatility compounds such as parathion and Kelthanee, are retained only partially (30% and 70%, respectively) on a fabric patch following 3-hr exposure at field condition^."^' More volatile chemicals, such as organic solvents or fumigants, therefore, will disappear from a gauze dosimeter in a much shorter time. In fact, the authors' preliminary studies showed that only 0.1% of a 25-rl deposit of toluene was retained on a traditional 16-la!c* gauze pad after 10 min. This report describes studies on charcoal cloth asa poitn tial absorptive dermal dosimeter for evaluating depositlor of volatile liquids on clothing or skin. Charcoal cloth 1s a 100%charcoal fabric which has shown good retention prop erties to various solvents and pesticide^."^' It was a n w pated, however, that quantitative measurements usingchrf. coal cloth as dermal dosimeters could be confounded b! tw factors: ( I ) partial evaporation from adsorbed liquids dw ing the study and (2) adsorption of ambient vapors of !hr studied material onto the dosimeter. The first factor will result in underestimating the lnllm amount of liquid which has deposited on the dosimeter. I C account for this factor, the retention efficiency ( R E ) of tb dosimeter for liquid depositions can be defined as folh*' Retained Liquid Deposit x 100 R E )'( = Initial Liquid Deposit (1) where "retained liquid deposit" is the amount of llqud remaining on the dosimeter at the end of the study. Because of the second factor, the total amount of collected on the dosimeter would include depositions Ira' both the liquid phase and the vapor phase. Since charto" cloth has a much higher adsorptive surfacearea than hum' skin, the amount of vapors adsorbed onto the doslflC' would be several times higher than the amount which be adsorbed onto a similar area of human skin. From Indbor. trial hygiene perspectives, only the liquid portion wouM of significance. This amount would be: eRetained Liquid Deposit = Total Amount - Adsorbed VaPon Equations I and 2 can be combined to yield the Initial Liquid Deposit Total Amount - Adsorbed vat Cr, RE/100 The total amount can be obtained from desorptionad analysis of the dosimeter. In order to characterize theOlrCr A. GENERAL - T-N-v - B. EXPOSURE CHAMBER Septum I I'I Glssl cove 'rl C h a r d c h h puch Figure 1-Apparatus for the testing of the charcoal cloth patches. :JCtCm. the authors studied, in laboratory settings, the Jd,orptive capacity of charcoal cloth for volatile liquids, the ,clcntion efficiency at various conditions, and the rate at &ch vapors adsorb onto the charcoal cloth. qaterials and Methods LJboratory study of charcoal cloth dosimeters was carried Jut in a controlled test atmosphere which included a vapor Gncration system (Figure I). The dual monitoring system masured (a)the total chemical evaporation from deposited .Iquidsby means of charcoal tubes (400/ 200 mg, SKC West, Inr.. Fullerton, Calif.) connected to a Gilian personal air umpling pump (Gilian Instrument Corp., Wayne, N.J.) and .b) a continuous record of the evaporation rate using an &ganic Vapor Analyzer (OVA)(Foxboro Analytical, North Haven. Conn.). The airflow into the OVA was monitored by Matheson model 602 rotameter (Matheson Gas Products, Inc.. Secaucus, N.J.). An identical rotameter also was n,talled on a sidestream to dilute sampled vapors when xcessary. An additional rotameter was installed at the out:et lithe apparatus to verify that no losses from the airstream xcurred along the study system. The commercially available charcoal cloth (MDA ScienXic. Glenview, Ill.) is derived from cellulosefabric which was xated chemically and physically to become 100%charcoal. cloth is a flexible, light (120 g/ m') fabric with a large *pzcificsurface area (350 to 1400 ~n*/g)."~T'he breaking lrrength of the cloth is only 1.5 kg/ cm, however, much lower b n fabrics normally used for clothing. Patches for laboratory experiments were made of one to ''a layers of 4.0-cm diameter circles sewn together. As these !osimeters were intended for use on workers in the field, it April. 1989 was necessary to protect the fragile cloth from potential abrasion. As a result, each dosimeter was tightly covered with a thin polyester fabric ("Horizon East"Japan, imported by Skinner, New York, N.Y.). Consequently, patches for laboratory tests also were covered tightly by the same fabric. Each patch was placed at the center of the exposure chamber and was allowed to equlibrate with the relative humidity and temperature for 10 min. capacity of Charcoei Cloth The capacity of charcoal cloth was studied by dosing a series of single circles with increasing volumes of toluene. The solvent was injected onto the center of each circle by means of a syringe with a nontapered needle (point style 3, Hamilton Co., Reno, Nev.) inserted through a septum in the glass cover of the chamber. Each circle was left in the chamber until no evaporation could be detected by the OVA and then was removed for extraction and analysis. Toluene was selected for this and other studies because of its polarity and moderate volatility. Retention Efficiency for Voiati/eLiquids A series of experiments .was carried out to characterize the retention of liquid chemicals by charcoal cloth as well as the evaporation from such deposits. The effects of the following factors on evaporation loss were studied: (1) number of char- coal cloth layers in a dosimeter, (2) deposit size, (3) vapor pressure and polarity of the chemical, (4) relative humidity, (5) air temperature, and (6) air velocity. The procedure of dosing the patch was asdescribed above. In most experiments, evaporation from the dosimeter was monitored by separate charcoal tubes during the first 10min after deposition ("shortterm loss") and during the following 170 min ("long-term 217 loss"). The evaporation during the first interval was monitored by the OVA also. Evaporation losses in both intervals of each run then were combined to obtain the total 3-hr loss. The total loss was later combined with the portion recovered from the patch for mass-balance evaluation. Adsorptlon of Vapors For the vapor adsorption studies, the airstream first was passed through a vapor generation chamber, which con- tained a diffusion tube (Figure I), before entering the exposure chamber. The amounts of toluene vapors generated were controlled by varying temperature, diffusion tube diameter, and diffusion path length. Charcoal cloth dosimeters used in these studies were made of two layers only. At the end of each run, the dosimeters were divided into segments of two charcoal cloth layers each. Each segment was placed in a 4-dram vial with a Teflon@-linedcap, and wasdesorbed into IO mL of carbon disulfide. Patches dosed with n-butanol or n-propanol were desorbed into a mixture of IO: 1 (v:v) carbon disulfide:2-propanol. Patches dosed with ethanol were desorbed into 10:I carbon disu1fide:npropanol mixture. Each section of the charcoal tubes was desorbed into 5 m L of the desorbing solvent. All vials were hand shaken for 30 sec prior to analysis. The samples were analyzed on a Shimadzu GC-FID (Shimadzu Co., Columbia, Md.) equipped with a IO ft, 1/8 in. O.D., 10% FFAP column on 80/ 100 chromosorb AW (Supelco, Inc., Bellefonte, Pa.) at the following conditions: carrier gas was nitrogen at I30 mL/ min, flame gases were hydrogen at 75 mL/ min and air at 700 mL/ min, and detector temperature was 165OC. Five-pL aliquots were injected. The desorption efficiencyfor each solvent was determined as follows. Two circles of charcoal cloth were dosed with IO pL of the tested solvent while in a 4-dram vial. The vials were sealed for 3 hr, after which IO mL of the desorbing reagent was introduced. The vials were hand shaken for 30 sec, and the solution then was analyzed. Calculated desorption efficiencies for each chemical are listed in Table 1. TABLE I Desorption and Analysis Data for Chemicals Desorbed from Charcoal Cloth and Tube Chemical -'On Charcoal Cloth Charcoal lube Column Temp. ("C) Retention Time (min) n-Hexane 100 100 95 0.49 Octane 99 99 100 0.70 Decane 100 99 100 1.37 Ethanol 92 99 110 1.58 .mPropanol 92 100 100 1 Butanol 94 97 140 1.18 Benzene 100 100 125 0.81 Toluene 98 100 125 1.18 *Xylene 99 100 125 1.38 1,3-DCP 96 97 145 1.37 218 1mgToluene emz Cloth 3 I 0 8 I I 1i 50 100 150 2# t pL Deposit Figure 2-Capacity of charcoal cloth for toluene. I, ! ICharcoal Cloth Neld Dos/lmeters Six sets of three field dosimeters were prepared for tesm! the retention efficiency in field conditions. Each dosimev was made of four 7.8 x 5.2-cm charcoal cloth layers sew' together and covered by the protective polyester fabric. Th: idosimeters were backed by a strong, polyethylene coal& belting material which preserved the rectangular shape 0 the dosimeters and protected it against wetting by sweat Th: dosimeters were kept in "zip-loc"polyethylene bags *hlr not in use, to prevent adsorption of ambient vapors. A h sampling, the dosimeters were returned to their bags ah' were stored in -20C or less until desorption. The entire fieL dosimeter was desorbed into 70 mL of carbon disulfideInr analyzed in a manner similar to that described abow. Results capacrry of charcoal cloth ' 1Figure 2 presents the average toluene content per cm' cloth calculated for each dose level. With increasing do* this content approached a maximum of2.8 mg/ crn*OraMY 65 PI- of toluene per gram of charcoal cloth. Such CaPc'" for liquid toluene approximates only 10% of the repond icharcoal cloth capacity for vapors of an unknown chcr ' Ihca~vIi.il'g' ~Ta'hrieslactaivpealcyitsymgaallpnpurmobbaebr loyf irnesteurlmteeddfiarotemsutheePco'@db # which are more accessible to liquid^,"^' compared lo number of micropores, which adsorb primarily vapors 'I Ir believed that further activation would enlarge the Pow increpsing their capacity for liquids. R8kntiOn Effkiency for Vokti/eLiquids * @Results of all retention efficiency studies are summarid Table I!. Mass balance on the retentionsand thecorres 2in.4g%tortaecl oevvearpyo.raTthiouns,lnoessaerslyinaalllltehxepaeprpimlieedntssoilnvdeincat 1Ie" d4*' run could be accounted for. Am. Ind. ffyg. &oc. J. (30) I (1) Evaporation pattern: Figure 3 describes the temporal pattern from a 25-pL toluene deposit remaining I ona &layer dosimeter for up to 8 hr after deposition. The decreasedtvaporation rate was high immediately after the deposition, rapidly in the followingfew minutes, and remained low thereafter. The IO-min short-term loss accounted for 28% of the initial dose, while only an additional 6% ,aporated thereafter. This evaporation pattern recurred in rll other studies, although the proportions between long- and short-term losses were different. (-7 ) Number of layers in the dosimeter: a significant differ- 1 (we (about 16%) in retention efficiencies for 25 pL of l ,,iuene was found between 2-layer and 4-layer dosimeters p not between 4-layer and 6-layer dosimeters. A 4-layer I joslmeter is preferred over the thicker 6-layers because of 1 .Juer costs of preparation and analysis and ease of handling. Ihcrefore, all other test dosimeters and field dosimeters 1 made of four charcoal cloth layers. 1 ( 3 ) Deposit size,air velocity, and relativehumidity: The 3-hr ,\aporation loss was found to increase geometrically with the dose(pL) and air veIocity(ft/ min)(Equations 4and 5, respectively)and exponentially with relative humidity (Equation 6). Log(1oss) = I .29 + 0.I69 Log(dose) Log(1oss) = I .34 + 0.0932 Log(air velocity) Log(loss) = 1.2 + 0.0057(%RH) RZ= 0.98 RZ= 0.88 R 2 =0.99 (4) (5) (6) (4)Volatility and polarity: The 3-hr evaporation loss was found to increase geometrically with the vapor pressure (Figure 4). While the regression lines for the solvent groups were steeper with increasing solvent polarity, statistical analysis of the data via analysis of the covariance indicated that the difference among the slopes was not significant at p = 0.05. Thus, a single regression line was constructed for all these liquids. ( 5 ) Temperature: The retention efficiency for 25 UL of toluene was 69.0 f 0.5% and 2OoCand 66.5 f 2.1% at 30C. This difference, although significant at p = 0.05, is relatively small. Thus, temperature effects within the normal work environment range can be ignored. TABLE II RetentionEfficienciesand Losses (Oh) of Solvents from Charcoal Cloth Patches" Variable VariableValue Total Loss Long-Term L o u Retention(oh) Mean SD Mean SD Mean SD Total Recovery Mean SD Number of 2 44.0 2.8 5.4 0.6 53.2 3.4 97.3 2.1 layers in 4 31.2 0.5 3.1 0.3 69.0 0.5 loo. 0.5 patch 6 30.9 2.5 4.4 1.1 69.3 1.o loo. 1.4 Deposit size (PL) 1 20.0 4.1 4.0 0.8 78.4 6.0 98.4 1.4 5 24.8 2.4 3.8 0.6 69.7 0.4 92.9 2.1 25 31.2 0.5 3.1 0.3 69.0 0.5 loo. 0.5 100 44.4 2.0 8.9 1.1 54.9 2.1 99.3 4.1 SoIvent decane 0.7 12.8 2.1 1.4 vapor butanol 4.1 19.4 2.3 4.7 pressure o-xylene 4.7 17.8 0.9 2.4 (mmHg) octane 10. 27.8 1.6 0.5 propanol 14.4 35.2 3.8 12.1 1,3-DCP 19. 33.7 2.4 7.2 toluene 24.7 31.2 0.5 3.1 ethanol 43.6 58.6 6.7 27.2 benzene 74.4 53.0 2.3 11.7 hexane 120. 62.8 8.9 8.0 0.4 86.7 1.5 99.5 0.9 1.o 79.4 2.9 98.8 2.7 0.3 80.4 1.3 98.2 1.I 0.5 67.9 1.1 95.7 2.5 1.3 64.3 0.5 99.4 1.5 1.2 63.5 2.0 96.6 2.3 0.3 69.0 0.5 loo. 0.5 2.9 35.8 3.1 94.4 4.1 1.1 42.9 0.9 95.8 0.5 2.0 38.3 2.4 101. 3.5 Temp. ("C) 20 30 31.2 0.5 3.1 0.3 69.0 0.5 100. 0.5 31.8 2.6 4.6 1.o 66.5 2.1 97.9 1.9 Relative humidity (%I 30 50 65 80 100 23.0 1.7 3.5 0.5 75.9 0.1 98.9 1.2 31.2 0.5 3.1 0.3 69.0 0.5 loo. 0.5 36.8 2.1 9.5 1.5 62.2 4.2 99.3 1.o 44.8 2.3 14.5 1.o 52.2 0.9 97.0 0.4 66.5 33.5 0.5 Air velocity (fpm) 12 27.1 3.0 3.3 1.1 74.3 1.o 101.5 2.2 29 31.2 0.5 3.1 0.3 69.0 0.5 loo. 0.5 72 34.0 1.o 4.7 0.6 66.1 1.o loo. 1.1 128 33.5 4.7 4.2 2.4 66.5 4.7 loo. 7.1 ~~ ~~~ 'Loss and retentiondata are theaverageof 3 runs.Runswere performedwith 25 pL of solventon4-layer patches at 2 0 C 50% RH,and 29fpm air velocity unlessotherwisestated.Toluenewas usedto study variables other than the vapor pressure. " E k = 0' 0 II1 I III 1 2 3 4 6 78 HWR 1 9 Figure 3-Percent of 25-pL toluene deposits remaining on 4-iayer patches at 2OoC,50%RH, and 29 f t h i n air velocity. SDs are contained within circles. -100 -50 a 4 to - f P -10 5- L 0.5 I 1 1 2 II I 5 10 20 Vapor Pnoure (nnHg) 1I 50 100 Figure 4-Effect of t h e vapor pressure on the total lossover 3 h r for 25-pL deposits at 50% R H and 29 ft/min air velocity. (6) Summary Model: The effects of the above factors on the retention efficiency of a 4-layer dosimeter were combined into a single expression. The data in Table I1 were log-transformedand submitted to multiple regression analysis. This analysis showed that the effect of the air velocity on liquid retention efficiencycould bedeleted with no significant change in the "goodness of fit," thus yielding the following empirical model: R E = 100 - 0.43Vpm x RH'." x DOSE'.'" R2= 0.85 ; C.V. = 7.3% (coefficient of variance) (7) whyre RE = retention efficiency (%); VP = vapor pressure (mmHg); R H = relative humidity (%); and DOSE = initial liquid deposit (uL). corr8 (7) Retention on gauze pad: The retention of tolueneOr traditional 16-layer gauze pad also was measured for parison purpose. The pad was dosed and analyzsedhioo'd tshimatiloafrtwheay25asptLheofchtoalruceonael dceloptohspitaeddso. nThtheeapnaadly,soinslOyr0a*'. e p L (0.1%) remained after IO-min exposure in the ch 220 @@@comtlobni.noefdve8fPfOec?t8of vapor concentration and exposure dumtaiorena on of the amounts of toluene vapor adsorbed per charcoal cloth can be described by a linear el (Figure 5). The effect of air velocity on vapor ad- Id ,,#P tion can be expressed by a geometric model (Figure It was assumed that very little interaction exists rr" I . nongthe above three variables as long as the absorbed r,,,ount does not approach the charcoal cloth maximum npacity (see above). It can be further assumed (but not ,tstcd herein)that adsorption of vapor is primarily a colliga- phenomenon. Under this assumption, the data were ,,bmitted to SPSS multiple regression analysis with log- ,,ansformed air velocity data, the regression line was forced lhrough the origin, and the following empiric equation ,ulted: AD = 0.021 x t x C x V Z R2 = 0.99 ; C.V. = 5% (8) *here A D = amount adsorbed (pmol/cm2); t = exposure duration (hr); C = vapor concentration (ppm); and V = air velocity (mi min). Charcoal Cloth Field Dos/meters Equation 3 provides the basic framework for evaluating the initial liquid deposit on the charcoal dosimeter. This equation requires the knowledge of the retention efficiency (Equation 7) and vapor adsorption (Equation 8). Note, that Equation 7 requires, in turn, the knowledge of the initial liquid deposit (DOSE). By rearranging Equation I to read --Initial Liquid Deposit = Retained Liquid x 100 - R L x 100 Retention Efficiency R E one can rewrite Equatim 7 as follows: R E = 100 - O.43VPo3O (RLx100/ (9) Where R L is the amount of liquid retained on the dosimeter by the end of the monitoring period. This equation can be solved by a trial-and-error technique. Table 111 presents estimated values for the retention efficiencycalculated by a FORTRAN program for different values of retained liquid, relative humidities, and vapor pressures. Once the retention efficiency is known, the initial liquid deposit can be evaluated from Equation 3. Field Testing of the Summary Model The accuracy of the summary model was tested in field conditions using six sets of three dermal dosimeters each. These dosimeters were dosed with known amounts of either /-400 -300 -*E .u a ---8 -200 8 i -100 0 0 I I I I I If 10 20 30 40 50 60 70 Exposure (ppn?x hours) 1 80 Figure 5-Adsorption of toluene vapors on charcoal cloth patches at 29 ft/min air velocity. k Ind Hyg. Auoc. I . (SO) April. 1989 221 The method's sensitivity and accuracy also can be greatl! affected by the adsorption of vapors. High vapor concentra. tion in the vicinity of the dosimeter may result in high "background" adsorption which could mask small liqulc deposits and also would increase the uncertainty in estimatinf the retained liquid fraction. For example, according I(, Equation 5 , 35 cm2 of dosimeter exposed to about 5 - p ~ ~ toluene vapor for 8 hr could adsorb about 12 mg of toluene With such background only large liquid deposits, about 4(! mg or more, could be confidently identified as being of a liquid source. It is believed that vapor adsorption may bc reduced by reducing activation of the charcoal and by co\ering the charcoal with a fabric more resistant to vapor but no1 liquid diffusion. I 12 II I 5 10 20 II 50 Id0 200 Air Velocity (ft/min) Figure 6-Effect of air velocity on the adsorption of toluene vapor onto charcoal cloth during 1 hr exposure at 7.5 ppm. toluene or Telone 11@ (a fumigant containing 92% 1,3dichloropropene) under agricultural field conditions and immediately were placed on the coverall of the investigator for 3 to 6 hr. The results of each experiment, as given in Table VI, indicated that retention efficienciespredicted by the model were within 20% of those observed. Discussion The dosimeters ideally should be used for monitoring highly toxic materials which are either harmful to the skin or can permeate the skin readily. Materials with high volatilit! (e.g.. vapor pressure around 10 mmHgand higher) should bc monitored only where ventilation effectively reduces vapor concentration. Chemical volatility also affects the usefulnes, of these dosimeters in a different fashion: a liquid deposit on the skin is subject to evaporation to the air on one sideand 10 percutaneous absorption on the other side. Thus, increased volatility means short contact period on the skin and ,therefore, minimal dermal absorption. The chemical toxicity and the work practices also should be considered in each case in order to determine whether the amounts of material likely 10 reach the worker's skin could indeed be harmful and warrant monitoring. Both laboratory and field studies have demonstrated the ability of charcoal cloth dosimeters to retain significant portions of volatile liquids deposited over a workday period. The effects of some variables have been characterized and can be accounted for. The value of some variables, however, cannot always be measured. For example, Figure 3 illustrates how evaporation loss is affected by the time elapsed since deposition. In actual sampling, this elapsed time may be unknown. Also not known is whether the liquid had deposited as a few larger droplets or many small ones. The possible errors these variables introduce, however, and the overall precision of the method, were evaluated elsewhere.`'6' It was shown that the method precision improved as the chemical volatility decreased. The coefficient of variance (C.V.) of the estimated retention efficiency (RE) was calculated to be C.V.(RE) = 18 (loo/RE - I). Similar to the gauze pad dosimeters, charcoal Cloth dosimeters may be used for monitoring exposure of unto\- ered skin and used underneath or over the worker's cloth. ing. Hand or face exposure can be monitored by attachinf dosimeters to thin cotton gloves or an operator's hat, respec. tively. Outside clothing exposure can be monitored by 81. taching dosimeters to an operator's gear by means of Velcro Material permeating through clothing can be documented by attaching dosimeters to an operator's underclothing Ort0 elastic bands wrapped around the extremities. i It is assumed that dosimeters not covered by Workep` 1 iclothing will have similar retention characteristics as tho% used under similar conditions in the laboratory tests. Therc` fore, the quantitative model can be used for calculatin~lhc I 'initial deposit on these dosimeters. Use of dosimeters under* neath clothing may help to evaluate the effectiveness t I TABLE 111 I Estimated Retention Efficienciesfor Charcoal Cloth Patches as a Function of Vapor Pressure, Retained Liquid, and Humi% Vapor Pressure (mmHg) 0.3 1.o 4.0 10 15 I ~~ @%RetalnLlquld(pL) 10 25 60 100 10 25 60 100 10 25 00 100 10 25 60 100 10 25 I Relatlve Humldity (YO) 30 -* I94 93 92 92 92 90 89 98 87 85 83 82 83 81 77 75 81 78 T5 50 91 90 89 88 88 86 84 83 81 78 75 73 75 71 66 63 72 67 6' 70 89 87 85 84 84 82 79 77 75 72 67 64 67 62 55 51 62 56 49 90 87 84 82 81 81 78 74 72 70 75 60 56 60 52 44 38 53 45 34 TABLE IV Retention Efficiency (RE) of Field Test Dorimeten Chomicri Vapor Pressure (mmHg) Doso (pL) Robtive Wind Humidity Velocity (H) (fpm) Expected RE (W Observed RE (W t Toluene 24.7 5 44 350 75.4 68.3 Toluene 24.7 10 47 55 70.6 66.1 Toluene 24.7 25 44 350 67.8 58.6 Toluene 24.7 50 47 55 63.1 59.7 1.3-DCP 19.3 3 80 570 67.1 65.4 1.&DCP 19.3 10 80 570 62.1 50.8 Pn`,gohtehctuimveicdliotyth, idnogsiinmseitreur.sbiuntsiidt eiscelxoptheicntegdwthilal thbaevceaulosewoefr ,tention characteristics. The ultimate goal for monitoring dermal exposure is to ,,aluate the potential harm posed by a process or setting. lhr:dermal dosimeter can be useful in the first step toward a goal, evaluating the amount of chemical deposited Onto the skin. This may be sufficient for irritants or allerp s . but for systemic toxicants, one would further need to know both the absorbed dose and the dose-response relationship. Estimating the absorbed dose is a field which still &rs more questions than answers.(l6'One approach would employ the percutaneous flux rate and the evaporation rate oia chemical to estimate "exposure time"and the fraction of a deposition which would be absorbed dermally. For example. 1.3dichloropropene has a measured vapor pressure of approximately 20 mmHg and an estimated human dermal [lux of about 30 pg/cm2/min.(15)It was shown that a 5-pL deposit will evaporate from 3.14 cm2 of exposed rat skin uithin I min, while a 50 ULdeposit over the same area will ctaporate in about 4 min. Based on the above data, it can be otimated that 0.5% to 1% of a 1,3dichloropropene deposit uould be absorbed by human skin if left in open air.(15)With more research, a general model could be developed which uill allow quantitative estimation of the absorbed fractions O i tolatile dermal doses. Conclusion Dermal exposure to a volatile chemical may prove at times IO be as significant as the respiratory exposure. This will be true for readily absorbed substances where work practices Jnd available protective clothing do not provide adequate protection to the skin. The charcoal cloth dosimeters were Jc\eloped for direct monitoring of the dermal exposure to \uch chemicals. Depending on the exposure characteristics, rhc dosimeters can be used for quantitative evaluation of bolatile liquid deposits, qualitative indicators of chemical iontact with the skin, or as a means for in siru testing of the cllectivenessof protective clothing. While it was shown that the dosimeters can retain volatile deposits over a workday Prlod, more work is needed to minimize confounding Clkctsof vapor adsorption and continuous evaporation and 10 Increase the dosimeter's capacity. Hyg Aswc. J. (SO) April. 1989 References 1. Treherne, J.E.: The Permeability of Skin to Some NonElectrolytes. J. Physiol. 733:171-180 (1956). 2. Malkinron, F.D.: Percutaneous Absorption of Toxic Substances in Industry Arch. lnd. Health. 2737-99 (1960). 3. Stewart, R.D. and H.C. Dodd: Absorption of Carbon Tetrachloride,Trichoroethylene,Tetrachloroethylene,Methylene Chloride and 1,1,l-trichloroethane through the Human Skin. Am. lnd. Hyg. Assoc. J. 25:439-446 (1964). 4. Feldman, R.J. and H.I. Maibach Percutaneous Penetration of some Pesticides and Herbicides in Man. Toxicol. Appl. Pharmacol. 28:126-132 (1974). 5. Jakobson, I.,J.E. Wahlberg, B. Holmberg,and G. Johansson: Uptake via the Blood and Elimination of Ten Organic Solvents following Epicutaneous Exposure in the Anesthetized Guinea Pig. Toxicol. Appl. Pharmacol. 63:181-187 (1982). 6. Spear, R.C., W.J. Popendorf, J.T. Leffingweil, T.H. Milby, J.E. Davis, and W.F. Spencer: Fieldworkers'Response to Weathered Residues of Parathion. J. Occup. Med. 79:406- 410 (1977). 7. Popendorf, W., R.C. Spear, J.T. Leffingwell, J. Yager, and E. Kahn: HarvesterExposureto Zolone (Phosalone)Residues in Peach Orchards. J. Occup. Med. 27:189-194 (1979) 8. Durham, W.F. and H.R. Wolfe: Measurement of the Exposureof Workersto Pesticides Bull. W. H. 0.26:75-91 (1962). 9. Popendorf, W.J. and J.T. Leffingweil: Regulating OP Pesticide Residues for Farmworkers' Protection. Residue Rev. 82: 125-201 (1982). 10. Cohen, B., E. Richter, E. Weirenberg; J. Schoenberg, and M. Luria: Sources of Parathion Exposure for Israeli Aerial Spray Workers, 1977. Pestic. Monit. J. 73:81-86 (1979). 11. Fenske, R.A., S.W. Horstman, and R.K. Bentley: Assessment of Dermal Exposure to Chlorophenolsin Timber Mills. Appl. lnd. Hyg. 2:143-147 (1987). 12. Serat, W.F., A.J. Van Loon, and W.H. Serat: Loss of Pesticides from Patches Used in the Field as Pesticide Collectors. Arch. Environ. Contam. Toxicol. 7 7:227-234 (1982). 13. Charcoal Cloth Ltd.: Charcoal Cloth: Technical Notes. Dorset, England: Charcoal Cloth Ltd. 1980. 14. MacNalr, R.N. and G.N. Arons: SorptiveTextileSystems Con- tainingActivated Carbon Fibers. In CarbonAbsorption Handbook edited by P.N. Cheremisinoff and F. Ellerbusch. Ann Arbor, Mich.: A n n Arbor Science Publishers, 1978. pp. 819-859. 15. Cohen, B.: "A Method for Measuring Dermal Exposure to Solventsand Fumigants."Ph.D. diss.: Universityof California, Berkeley, 1984. 16. Scheuplein, R.J.: Percutaneous Absorption after TwentyFive Years: Or "Old Wine in New Wineskins." J. Invest. Dermatol. 67:31-38 (1976). 22 March 1988; Revised 24 September 1988 223