Case 11 of Table 2 fits the conditions of;the problem if only free convec tion heating of the pipe is assumed. The equation in.this case is as follows:
/ P\V /aV
(16)
where
therefore,
Af = 20:F'
:\ :
D = 0.364 ft 'i
'
..... P Po = one atmosphere
/ 20 V s
-:-
.... K = 0.737'Btu per (hr) (sq ft) (F deg).
Using the surface area of the insulation, the value of the resistance per unit length is determined. ,
sq ft
1. Re = hcA 0.737 X 1.14
Re = 1.19 (hr) (F deg) per Btu.
This result" may not be deemed conservative inasmuch as the expression is for still air. If, however, the air is not still, but flows at approximately 5 mph or 7 fps, the heat transfer equation for forced convection would apply.
This equation is Case 5 of Table 2.
(^.P)0* heaven*.) = 0.211(T,) D<
(17).
Ti = ^
460 = 570 Rankine (Fahrenheit abstract)
u. = 7 fps
p
=
0.076 (
=
\570/_
0.0694 lb
per cu ft .
D = 0.364 ft
0.211(570) "(7:X 0.0694)0-8
"c("'"w) -
(0564)0.4
hc(vew) = 2.73 Btu per (hr) (sq ft) (Fdeg)
and
11 Re (Forced Convection) = he A 2.73 X 1.14
Re = 0.321 (hr) (F deg) per Btu. .
The radiation resistance, Rr, which acts in parallel with the resistance just calculated, can be computed with the aid of Fig. 7. The pipe wall, assumed at 100 F sees the surroundings at 120 F. If these two tempera-
Heat Transfer
105
tures are used with Fig. 7, a value for pr-rr is determined directly.
c A* E
h, 14 Btu per (hr) (F deg) (sq ft).
PjlFe
The angle factor, FM is unity, and for an estimated surface emissivity of 0.95 (see Table 3), FE = 0.95. Therefore,
K = 1.4 F*F = 1.4 X 1 X 0.95
h, = 1.33 Btu per (hr) (F deg) (sq ft)
and the radiation resistance, Rt, is then the following:
h,A 1.33 X 1.14
i ! Re = 0.659 (hr) (F deg) per Btu.
The resultant resistance of Re and Rt acting in parallel (see Fig. 8) can now be evaluated:as: i
A R<
RLe + Re
6^+ oi = 4 54 Btu per (hr) (F deg)
Rt =* 0.216 (hr) (F deg) per Btu.
The overall resistance, Rt, surroundings to cold water, is the stun of R\ + Rt + R + Rt = 4.12 (hr) (F deg) per Btu for 1 ft length of pipe. Note that the controlling resistances are Rt and Rt, and that neglect of both Ri and Rj would not significantly influence the total'resistance, Rt.
On the basis oif this resistance calculation* the heat transfer from the surroundings to the cold water may be evaluated as:
! ' % =' l' = 12?1934 = 20.8 Btu per (hr) (ft)
iv' iCt
4.12
j
or about 0.175 tons of refrigeration per 100 ft of pipe. Since the calculation is based on a 1-ft pipe length:
g,, =. 20.8 Btu per hr.
The temperature drops through the various resistances are now readily evaluated by Equation 14 as:
At = qR
lo -- tee (air to insulation surface) = gRi =. 20.8 X 0.216 = 4.49 F deg
t`j -- la (through the insulation) = gRe = 20.8 X 3.9 = 81.2 F deg
tn -- t,i (through the pipe wall) = gRe = 20.8 X 8.5 X 10"'* = 0.018 F deg
fi -- ti (pipe wall to cold water) = gRi = 20.8 X 3.73 X 10"' = 0.078 F deg
. .This solution was obtained on the temperature distribution assumptions initially made. It is apparent that a better solution could be obtained if the whole problem were reiterated using the temperature distribution just calculated.