Document 8j8vzdnQykL3v6kr7EGjbGZ5
FILE NAME: ALCOA (ALC) DATE: 1948 July 2 DOC#: ALC077 DOCUMENT DESCRIPTION: Memo
Fr o m
G. D. DICKSON
IN TERN A L C O R R E SPO N D E N C E
July 2, 1948
T o DR. LESTER V. CRALLEI
\.
n'
PITTSBURGH OFFICE
NEW KENSINGTON RESEARCH LABORATORIES
RE.- SAFETY CLOTHING AND EQOIPtffiNT
X.
You have previously been advised of the Company's Standardization
of Stores Material program and in particular that section dealing with
safety clothing and equipment known as Employee Sales Classification #22.
The final list of approved items carried under classification #22 was
released April 9, 1948 to all storekeepers who were asked to review their
stocks and report any deviation from the approval list to Lr. Bradshaw.
This procedure has been followed and to date we have experience relatively
few deviations. One in particular which we wish to call your attention to
is respiratory protective equipment.
The final approved list of respirators included the following
types:
Hazard
Make of Respirator
lifer.Catalog No.
Metal Fume Respirator Pneumoconfasis Producing
H.S.A. Comfo.
and Nuisance Dusts
American Optical
Toxic Dusts
American Optical
All Dusts
M.S.A. Dustfoe
(Pneumoconiosis-Producing & Nuisance Dusts
Toxic Dusts)
Mist
M.S.A. Comfo
Organic Vapors (Paint Spraying)
k.S.A. Chemical Cargridge
(Indicates revision in catalog number)
CR-44752 *
AO-R-9100 AQ-R-9100T Cit-46162 *
CR-44752 CR-44158
All of the above respirators are approved by the Bureau of Nines
for the specific hazards listed. For example,
FVjme Type Respirators are approved for protection against the inhalation
of solid dispersoids or particulate matter formed by the condensation of
vapors such as those from heated metals and other substances.
Pneumoconiosis-Producing and Nuisance Dust Type Respirators are approved for
protection against inhalation of pneumoconiosis (silicosis and asbestosis) producing dusts, such as free silica and. asbestos; and nuisance dusts
A R D 043004
F O X 042867
July 2, 1948 2-
such as free silica and asbestos; and nuisance dusts such as aluminum, cellulose, cement, coal, coke, gypsum, limestone, and wood. Toxic Dust Type Respirators are approved for protection against inhalation of toxic or piosonous dusts, such as lead, cadmium, arsenic, chromium, manganese, selenium, vanadium and their compounds. All Dust Type Respirators are approved for protection against inhalation of all dusts - pneumoconiosis producing and nuisance dusts plus toxic dusts* Mist Type Respirators are approved for protection against inhalation of pneumoconiosis-producing, chromic acid and nuisahce mists* Organic Vapor Type Respirators are approved for protection against inhalation of organic vapors of concentrations not exceeding 0,1 percent by volume, such as acetone, alcohol, benzene, carbon tetrachloride, ether, formalde hyde, gasoline, petroleum distillates and toluene. For paint spraying operations this type respirator will afford protection against inhalation of the paint vehicle. An auxiliary paper screen is recommended to filter out the pigment.
The list of respirators selected and approved for the standardiza tion program was determined (l) oh the basis of Bureau of Mines approval and (2) on the popular choice of such approved equipment in use at our plants* */e have leaimed from the Otters received from storekeepers listing deviations from the standard approved list of respirators, that some
locations have experienced difficulty IH conforming to the approved list.
They report that employees have refused td use the approved equipment, claiming it to be uncomfortable, heavy and annoying* They prefer instead to wear the old style gauze masks'or other unapproved (i*e.. not approved by the Bureau of Mines) respirators which they have been accustomed-to using in the past. In some cases the preference is for other makes of respirators which have the Bureau of Mines approval. Where the preference is for other Bureau of Mines' approved respirators, we have and will promptly
A R D 043005
FOX 042868
July 2, 1%8 -3-
okay it as an equivalent item. However, we are opposed to the use of the
old style gauze mask or respirator not approved by the Bureau of Mines.
Vie urge you to exert your influence to persuade the employees to adopt
the use of Bureau of Mines approved respirators. Vie recognize the diffi culty of converting people to the use of a new type respirator, particularly when it is not as comfortable as the type they have been wearing. It is more difficult when any mandatory stand by the Company precipitates a controversy. It is a problem that we believe can be solved by patience and persuasion.* It is a problem which rests directly with Management and one which will require tactful handling. V/e have a twofold objective, (1) to provide adequate protection against health hazards and (2) to afford the Company maximum defense against fraudulent disability compensation claims.
As an illustration of how this problem might be approached we cite the case at one of our locations vdiere exposure to a chemical product
tf
necessitated a complete change of clothing and a shower following the days work. Employees objected to this requirement and refused to cooperate with Management. Their union committee was asked to attend a meeting for a discussion of the subject and were tactfully told that a health hazard existed if employees wore their clothes home from work and if they failed to bathe following this exposure. When the seriousness of the situation was presented in a business like manner and was fully understood and appre ciated by the union committee and employees, their attitude changed and the problem was solved. The significant point was, that when the employees were informed and recognized the merits of the program they cooperated, /e believe in the case of approved respiratory equipment they will also cooper ate if we use the correct approach
A R D 043006
FOX 042869
July 2, 1948 -4-
As a possible aid in selling the Bureau of Mines approved respirators to employees at your location, vre recommend the Mine Safety Appliances1 16 ram. sound motion picture, "The Air We Breathe." This film produced by the Wilding Pictures, Inc. is dramatically staged with professional talent and should be an excellent medium of selling our people on the use of approved respirators. Should you wish to borrow this film, contact your nearest li.S.A. representative or write this office and we shall arrange to borrow it for you.
GDDrmp
G. D. DICKSON
Same letter to all W orks Managers Safety Supervisors District Purchasing Agents Storekeepers
Copies to Dr. D. A. Irwin Dr. L. V. Cralley Mr. A. R. Hamilton
ARD 043007
FOX 042870