BASECOAT PLASTERS
DESCRIPTION
RED TOP* STRUCTO-LITE* PLASTER
Red Top Structo-Lite plaster is a high quality basecoat plaster formulated at the mill by proportioning a select expanded perlite with gypsum plaster.
Structo-Lite is packaged in 80 lb. bags (regular) and 67 lb. bags (masonry) and requires the addition of clean water only on the job.
Complies with A.S.T.M. Designation C28-50 for "Gvpsum Readv Mixed Plaster." The perlite used com plies with ASTM Designation C35-53T `'Inorganic Aggregate for use in Interior Plaster."
FUNCTION AND UTILITY
1. Uniformly Strong Walls--Proper proportioning of ce ment plaster with a well graded, controlled-density, perlite aggregate and a mill-controlled set that help insure strength in the plaster slab.
2. Uniform Hardness--Because the perlite in StructoLite plaster is manufactured to conform with exacting specifications for density, strength and gradation, and is thoroughly mixed with the cement piaster at the mill.
3. Over Fifty Per Cent Less Weight in the finished plaster. Laree savings in framing costs are possible due to this saving in weight.
4. More Fire Resistant--Greatly increased fire resistant ratings over those attained with sand in plastered walls and ceilings. Ideally suited where building code requirements demand maximum fire ratings not attainable with sand. For example:
a. Ys" Perforated Rocklath plaster base attached to wood studs spaced 16" o.c. with R-l Resilient Clips, plastered to Z2" grounds with Structo-Lite--1 hr. fire rating.
b. Ys," Perforated Rocklath nailed to wood joists spaced 16" o.c. and plastered to } >" grounds with Structo-Lite--1 hour fire rating.
Ys"c. Perforated Rocklath attached with Brace-
Tite clips to Trussteel Studs, plastered to Y" grounds with Structo-Lite--1 hour fire rating.
*TrademaTks Reg. U. S. Pat. Of.
i REDTOP
STRUCK) LITE E-MIXfD PIBUTIO
i 6YPSUM I PLASTER
tmiiao
vmv** Mw
d. Steel joists 24" o.c.: 2" concrete over
rib
Ys"lath top of joists:
perforated Rocklath at
Yi"tached with Brace-Tite Clips to
channels 16"
o.c. wire-tied to joists, plastered with Structo-Lite
to 5 g" grounds--1 hour fire rating.
Structo-Lite plaster, having a mortar weight of half that of a gypsum-sand plaster proportioned 1:3, still develops comparable tensile and compressive strengths. Structo-Lite is strong, quick-drying, light weight, and easy to finish over.
"k" FACTOR = 1.4 (approximate) or about 3 times the insulation value of a gvpsum-sand basecoat.
LIMITATIONS
Same as paragraphs 2 to 8 under Limitations for use on Red Top Cement Plaster, page 4.
9. On jobs where Structo-Lite is used to plaster over radiant panel heating systems, the system must be designed by the heating engineer to allow for the in sulating value of Structo-Lite. If the design did not contemplate an insulating value equivalent to that of Structo-Lite, do not use it over radiant heating panel portions of the job. See Limitation 8 referred to above.
Page 3
CH016 1160
*
BASECOAT PLASTERS RED TOP CEMENT PLASTER
DESCRIPTION
Red Top Cement Plaster is a neat gypsum plaster re quiring the addition of an aggregate and water on the job. It is the basecoat that receives the finish coat plaster.
Complies with ASTM Designation C28-50 for "Gypsum Neat Plaster" and Federal Specification SS-P-402, Type N.
FUNCTION AND UTILITY
RED TOP Cement Plaster is used for scratch (1st coat) and brown (2nd coat) wherever good plastering aggre gate is available.
Fireproof--Made from gypsum rock, it is incombustible and will not transmit high temperatures until completely calcined; a slow process. In this respect, gypsum plaster is unique. See fire test data page 6, for authoritative fire ratings.
Adaptable--Red Top Cement Plaster bonds firmly with Rocklath plaster base, metal lath, fiber insulation lath, Pyrobar gypsum partition tile, clay tile, porous brick and certain other approved plaster bases.
Red Top Cement Plaster is the standard of excellence for receiving such finish coats as lime, putty, keene's cement, gypsum trowel finish, gypsum float finish, Oriental* interior colored finish, acoustical plasters, etc. It is excellent base for adhesive application of acoustical tile.
Red Top Cement Plaster is plastic, permitting wide lati tude in its use for plain or curved surfaces.
Uniform--Red Top Cement Plaster is manufactured on a nation-wide basis within narrow limits of tolerance. Its "stabilized set" minimizes the hazards due to impure water or aggregate and job conditions. Its set is ad justed for seasonal conditions.
Strong -- When mixed with good sand according to specifications, Red Top Cement Plaster has a compres sive strength up to 1,200 lbs. psi for normal mixes (see test data, page 6). It is capable of withstanding normal wear and usage for the life of the building.
Economical--Red Top Cement Plaster is lowest in cost of the various types of gypsum basecoats because:
The neat plaster is low in cost and is mixed with eco nomical aggregate which increases bulk and coverage.
Red Top Cement Plaster is highly plastic, thus is easily and quickly applied by the mechanic.
Normal usage requires little or no maintenance.
Page 4
RED TOP
6YP8UM
CEMENT
PLASTER
varrst
IU U **T. O#*
S
,Js
I
A*.
LIMITATIONS OF USE
1. Red Top Cement Plaster should have aggregate added strictly according to specifications. Use of too much ag gregate drastically decreases its strength. Sand content is easily calculated. A No. 2 shovel full of damp sand weighs approximately 15 lbs. The light weight aggre gates are generally shipped in 3 or 4 cu. ft. bags.
2. Two coat plastering not recommended over fiber insu lation lath.
3. Under no conditions should Red Top Cement Plaster be applied to concrete. Use Bondcrete* Plaster, de scribed on page 5.
4. Red Top Cement Plaster should not be used where contact with excessive water or moisture is expected. In such instances, use portland cement-lime plaster.
5. Red Top Cement Plaster is an interior basecoat plaster and should not be used on the exterior where exposed to the elements.
6. Because bituminous compounds do not provide an
ideal base for gypsum plaster basecoats, placer applica tion on masonry walls and concrete that have been coated with these compounds is not recommended.
7. Due to possibility of condensation or water seepage, plastering direct to interior side of exterior masonry walls is not recommended. Furring such walls prior to plastering is rocommendod.
.8 When used in conjunction with radiant heating sys
tems, the temperature at the surface of the plaster shall not exceed 115 Fahrenheit. The thermal conductivity of gypsum-sand plaster is approximately three times that of a gypsum-lightweight aggregate^mix.
* Trademark Reg. U. S. Pat. Off.
BASECOAT PLASTERS
r
RED TOP WOOD FIBER PLASTER
BONDCRETE* PLASTER
UpS' O
D
RED
rv
top
WOOD FIBER PLASTER
wfTe rTAHi
****
I
St
I
I
DESCRIPTION
Red Top Wood Fiber Plaster is a factory-prepared gypsum basecoat plaster containing finely-shredded, se lected wood fiber. It requires the addition of water only on the job. Complies with ASTM Designation C28-50 "Gypsum wood-fibered plaster" and Federal Specifications SS-P402, Type W.
FUNCTION AND UTILITY Stronger--Compared to plaster sanded 1:3, Wood Fiber
Plaster has: 3 times greater compressive and tensile strength. 2A times greater resistance to lateral impact. 50 per cent greater surface hardness. Consequently, has greater resistance to cracking.
Fireproof--Generally 50 per cent more fire resistant than sanded piaster. See ratings on page 6.
Factory Prepared--Particularly suitable where good ag gregates are unavailable. Avoids dangers of improper proportioning of aggregates.
Lightweight--Dead load is 25 per cent lighter than sanded plaster.
Cost--A wood fiber basecoat plaster job costs approxi mately 10 to 15 per cent more than Red Top Cement Plaster sanded on the job.
LIMITATIONS
Same as paragraphs 2 to 7 under Limitations for use of Red Top Cement Plaster, page 4.
*Trademark Reg. U. S. Pat. Of.
TuT o
BONDCRETE*
gypsum plaster for concrete
\
!
uaim r>m "* co
T.M ft*. w s-
*f-
> :y
DESCRIPTION
Red Top Bondcrete is a gypsum basecoat plaster spe cially formulated to bond with rough interior monolithic concrete surfaces. It is factory prepared, requiring addi tion of water only on the job.
There are no ASTM or Federal Specifications cover ing this type of plaster.
FUNCTION AND UTILITY
Bondcrete is plaster especially prepared for application to concrete. It provides the bonding plaster to receive a browning, or leveling, coat of Red Top Cement Plaster or Wood Fiber Plaster when necessary.
If a leveling coat is unnecessary, the finish plaster may be applied directly to the Bondcrete. ' *
Bonding Strength--Bondcrete adheres well to properly prepared concrete surfaces. See Surface Preparation un der Specifications for proper conditioning of concrete surfaces. This is important.
The thermal coefficient of expansion of Bondcrete is approximately the same as for concrete.
tow Coct--An economical bonding coat to provide for the application of piaster direct to concrete surfaces.
LIMITATIONS OF USE
1. Bondcrete should be used only on concrete that is properly prepared for plastering. It should never be applied to smooth concrete. (See Red Top Cover Coat, page 10.)
2. Maximum thickness of Bondcrete and basecoat shall not exceed %" on ceilings or 5/s" on walls. If additional thickness is required, metal lath shall be secured to the concrete surfaces.
3. The same as paragraphs 4 to 8 under.Red Top Cement
Plaster, page 4.
4
Pge S
CS016 1162
BASECOAT PLASTERS TECHNICAL DATA -- AVERAGE TEST RESULTS
(NOTE--results from separate producing plants may vary somewhat--above or below these average figures)
FIRE TEST DATA
(All tests made at nationally recognized fire testing laboratories)
(A) lofh applied with 1 Vi", 13 gauge noil*, %" head and joints covered with Striplath. 1 Y*" nails. IBI lath applied with VAtf, 11 gouge, head barbed roofing nails, 6" O.C. (Cl 2Vin reiniorcod concrete slab on RibJoth or 2" precosf gypsum tile above. ID) Ceiling 9" or more below floor slob. IE) Ceiling 3" or more below floor slab. (F) Self-furring metal lath wrapped tight to column or diamond mesh on channel frame not filled solid to column.
CS016 1163
FINISHING PLASTERS
r DESCRIPTION
ESSENTIALITY OF COMPLETE HYDRATION IN
The finish coat plaster provides the base for final wall or
DOLOMITIC FINISHING LIMES
ceiling decoration. It is applied to a thickness of Hi" to H", usually over a gypsum plaster basecoat.
Several types of finish coats are available, each with characteristics to serve specific requirements, and gen erally classified according to the principal cementitious ingredient as follows:
Some years ago an exhaustive investigation was under taken by the National Bureau ofStandardsinco-operation with several architects and lime manufacturers to deter mine reasons for "lime bulges" (delamination of finish from basecoat) occurring on many government and private buildings. The failures investigated occurred on
1. Lime and Gauging, commonly known as "white coat" for a smooth white trowel finish. 11 consists of lime, soaked
surfaces which had been "white coated" with dolomilic hydrated finishing limes from the Ohio fields, which
to a smooth putty, and mixed with gypsum gauging
have been widely used. Failures often occur 5 or 10
plaster. With addition of sand, is adaptable for sand float finishes. The three essentials to a good white coat job are:
years after erection of the buildings. After much analysis, it was the consensus of opinion
that the delayed hydration and attendant expansion of
a. Lime must be highly plastic and completely hydrated.
unhvdrated oxides in the "normal" dolomitic finishing
b. Correct proportioning of gauging plaster to lime putty
limes resulted in bulging and delamination.
(see specifications) and thorough blending of ingredients.
To correct this difficulty, United States Gypsum Com
c. Careful application and sufficient trowelling to pro
pany took the lead in developing "Ivory"* Double
duce a smooth glossy surface.
Hydrated finishing lime, a "fully" or "pressure" fless
i than 8 per cent unhydrated) hydrated Ohio dolomitic
2. Lime and Keene's--for extra hard smooth white trowel
finishing lime.
finish. With addition of sand, is adaptable for sand float finishes. Also available mill mixed and colored under "Oriental"* Interior Finish brand.
3. Gypsum--Trowel (smooth), or sand float prepared finishes.
4. Acoustical Plaster--(Sabinite*), (USG Hi-Lite) for sound absorption. (See page 10 and AIA Folder 39-B.)
ASTM specifications (2206-49 for special finishing lime and proposed amendments to Federal specifications, have been written to cover 92 per cent hydrated limes; a specification has been published by the National Lime Association. This type of finishing lime is required by ASA Specifications for Gypsum Plastering, A42.1-1950.
Note that all high calcium hydrated limes (properly soaked) comply with these requirements as do high calcium quicklimes (properly slaked).
CS016 1164
Trademark Reg. U. S. Pat. Off.
Page 7
FINISHING PLASTERS --CO NT.
LIME PUTTY -- GAUGING (WHITE COAT) FINISH
DESCRIPTION
Hydrated Finishing Lime (or Finishing Quicklime) is soaked (or slaked) to putty consistency, blended in proper proportion with gypsum gauging plaster, and is trowelled to a smooth, hard finish usually over a properly prepared gypsum basecoat. This is by far the most widely used plaster finish coat due to ease of application, flexibility, whiteness and economy.
The function of lime in a finish plaster is to provide the "spread" and plasticity to permit fast, easy application with full flexibility and economy. Lime does not "set," but hardens slowly; it likewise shrinks on drying. Therefore, gypsum gaug ing must be blended into the lime in proper proportion to pro vide initial set and strength, and to avoid shrinkage cracks.
IVORY*--A double hydrated (over 92%) special finishing lime that will not expand measurably in the wall. Requires no soaking to produce a smooth, uniform, white, highly plastic putty. May be mixed by adding dry lime to water in mechanical mixer be cause it develops its normal plasticity almost immediately then adding gauging. This is the preferred lime. Meets ASTM Des ignation C206-49 Type S and Federal Specification SS-L-351, Type F. including the added requirement of not more than 8% unhydrated oxides.
RED TOP and GRAND PRIZE*--Shipped from Genoa, Ohio, are normal dolomitic hydrated finishing limes, and are only par tially hydrated. They comply with ASTM Designation C6-46, Type N, and Federal Specification SS-L-351, Type F, but do not comply with specifications limiting the unhydrated oxides to 8 per cent.
RED TOP Hydrated Limes shipped from Farnams, Massachusetts and New Braunfels, Texas, are high calcium limes and are com pletely hydrated. They comply with ASTM C206-49 Type S and Federal Specification SS-L-351, and meet specifications limiting the unhydrated oxides to not more than 8 per cent.
All types of USG* hydrated lime except Ivory Finish Hydrate require overnight soaking. They yield a smooth, highly plastic putty of exceptional purity. Until the advent of pres sure hydrates, such as Ivory, they were the standards of excellence.
RED TOP and CHESHIRE Brands--Are high calcium finishing quicklimes. When properly slaked and aged for at least 16 hours, hydration is complete, (over 92%) thereby insuring against further hydration and attendant possibilities of expan sion on the wall. Comply with ASTM Designation C5-26, and Federal Specification SS-Q-351. They have unusually high plasticity and purity.
)
GAUGING PLASTERS
1. CHAMPION* and STAR* are WHITE Gauging Plasters, for blending with lime putty to provide initial set and strength. They are ground to the proper fineness to blend readily and completely, thus minimizing the danger of check-cracking, crazing, etc. when properly used. They give strength and hard ness to the surface finish. Champion has a quicker "set" than Star Gauging Plaster. They are the preferred gauging plasters because of the extreme whiteness of the finish when used with limes of high purity.
Complies with ASTM Designation C28-50 "Calcined gyp sum for finishing coat" and Federal Specification SS-P-402, Type G.
2. RED TOP GAUGING is a "local" gauging plaster, so called because it is made from a rock grade that is used in basecoat plasters. It is available with slow or fast "set." It is distinguished from White Gauging Plasters by its darker color. Except for color, Red Top Gauging Plasters are the equal of Champion and Star Gauging Plasters.
Compliance is the same as for "white" gauging plasters above.
3. STRUCTO-GAUGE is a new high strength gypsum gauging plaster for use with lime-putty to produce surfaces of extreme hardness and durability, designed for use in hospitals, schools and other buildings where a hard finish is desired. StructoGauce has excellent mixing qualities, applies easily and re quires a minimum of troweling to produce a smooth finish.
Page 8
Complies with ASTM Designation C28-50 "Calcined gyp sum for finishing coat and Federal Specification SS-P-402, Type G, and, in addition, has a compressive strength (dry) of not less than 5000 psi.
PROPORTIONING--See Specifications
t
LIMITATIONS OF USE
1. For interior application only.
2. Recommended proportioning must be observed. Failure to use sufficient gauging plaster, to blend thoroughly, or to trowel adequately often results in check-cracking, crazing, lack of hardness and bond failure.
3. Designed for normal humidity conditions. Where higher humidity or exposure to wetting is expected, use Keene's Cement or Structo-Gauge.* If humidity or exposure to moisture is extreme or continuous, use portland cement-lime plaster.
4. Designed for normal usage. If greater hardness, and resist ance to abrasion arc required, use Keene's cement or StructoGauge.
5. Must be applied to gypsum or lime plaster basecoat. The bond of lime putty gauging finish to portland cement plasters is inadequate. Do not apply direct to masonry.
Trademarks Reg. U. S. Pat. Of.
CS016 1165
i
FINISHING PLASTERS--CO NT.
KEENE'S-LIME FINISH
DESCRIPTION
Red Top keene's cement is a high strength, white gyp sum piaster. Keene's-lime finish is composed of lime putty blended with keene's cement in proportions re quired to obtain desired hardness.
Complies with ASTM Designation C61-40 and Fed eral Specification SS-C-161, Type I (Regular) and Type II (Quick Troweling).
FUNCTION AND UTILITY
In addition to those listed for lime putty-gauging, are:
Resistance to Abrasion. Keene's cement has exception ally high strength and surface hardness. See Technical Data on page 7.
Low Water Absorption. Keene's cement, having a high density, has low water absorption.
Choice of Hardness. Keene's cement is mixed with lime putty in varying proportions for "hard" and "medium hard" finishes. See Technical Data and specifications.
Two Types. Regular and Quick Troweling. Regular keene's sets slowly, requires more troweling and may be used with any proportion of lime.
Quick Troweling keene's sets faster, requires less troweling and must be used with a minimum of 25 lbs. of dry hydrated lime per 100 lbs. of keene's cement.
LIMITATIONS OF USE
1. Keene's cement is for interior finishes only.
2. Keene's cement finish is not recommended where ex posure to water is extreme or continuous. Use portland cement-lime plaster.
3. For application over gypsum basecoats of high com pressive strength only.
MOULDING PLASTERS
Moulding Plasters are made for use in specialized work such as casting ornamental enrichments or running cornice. Moulding Plasters may be used either neat or with the addition of lime putty. In cast work, moulding
plaster is used neat whereas for running cornice a small portion of lime is used. Moulding Plaster is available in white and local grades as well as in quick or slow set.
CASTING PLASTER
Red Top Superfine Casting is similar to Red Top White Moulding Plaster except that it has a much finer particle size. It is ideal for use in modeling done directly in the
plaster. The fine particle size results in smoother castings showing excellent detail--important in the making of fine plaques and art statuary. Only water is added in mixing.
PREPARED GYPSUM FINISHES
RED TOP Gypsum Trowel Finish and RED TOP Gypsum Sand Float Finish
DESCRIPTION
Red Top Trowel and Sand Float finishes are mill-pre pared gypsum finish coat plasters requiring the addition of water only.
There are no ASTM or Federal Specifications cover ing this type of plaster.
FUNCTION AND UTILITY
RED TOP Gypsum Trowel Finish--is used where hard, smooth surfaces are desired.
RED TOP Gypsum Sand Float Finish--is used where a quality float finish is desired.
Strength--approximately twice the strength of ordinary lime-gauging finishes.
Early Decoration--may be painted as soon as set and dry.
Factory Prepared--mill selection of ingredients and formulation insure uniform results and avoid variations possible with job mixing.
Non-Alkaline--contain nothing injurious to paint or decorations.
Bond--provides durable and natural bond to gvpsum basecoat.
Cost--slightly higher than job-prepared finishes.
LIMITATIONS
1. Designed for application over gypsum basecoats only. 2. Should not be used on exterior surfaces where exposed to the elements or on interiors exposed to excessive moisture.
Page 9
CS016 1166
FINISHING PLASTERS--CONI
RED TOP COVER COAT FINISHING PLASTER
DESCRIPTION
Red Top Cover Coat is a mill prepared white gypsum bonding-finishing plaster requiring the addition of water only.
FUNCTION AND UTILITY
Red Top Cover Coat is a specially prepared finishing plaster designed to furnish an adhesive bond for appli cation direct to smooth unpainted concrete (to which application of Bondcrete is not suited) and provide a finish surface ready for decoration. Application specifications provide for one coat work, which is most economical and provides customary finish appearance; and two coat work, which provides a supe
rior finish appearance. If sand float finish is desired, it must be two coat work.
LIMITATIONS
1. For interior application only. 2. Not recommended for application on exterior ma sonry walls.
3. Not designed for use on surfaces which are exposed to excessive humidity or where frequent exposure to water is expected.
4. Unprotected steel in surface of concrete may result in rust spots on Cover Coat, requiring subsequent decoration.
5. As a finishing plaster it is designed for application in a total thickness not to exceed an average of }/g of an inch.
ORIENTAL* INTERIOR COLORED FINISHES
DESCRIPTION
Oriental Interior Finish is a mill-prepared and colored finish plaster requiring the addition of water only.
There are no ASTM or Federal Specifications cover ing this type of plaster.
FUNCTION AND UTILITY
Integrally Colored at factory, requiring no decoration. Permits early occupancy. Avoids variations of color in tensity that are possible when colors are mixed at site.
Colors (with LIGHT REFLECTION for float finish). White--81%: Pewter Gray--52%; Surf Green--56%; Old Ivory--77%.;
Desert Rose--56%; Azure--58%; Sahara Gold--63%,.
Texture--A finely floated surface or special textured finish may be obtained.
Strength--highly resistant to abrasion due to very great hardness.
LIMITATIONS OF USE
1. Oriental Interior is for producing finely floated sur faces or textures. Do not use for a smooth finish. 2. To be used on interiors only.
))
ACOUSTICAL PLASTER FINISHES (See full data on pages 2 and 3 Sec. lOa-uni)
Sabinite* acoustical plaster
DESCRIPTION
Sabinite Trowel Finish is a highly efficient acoustical plaster, scientifically prepared to produce a continuous trowel nr float finish of exceptional sound absorbent qual ities. It is manufactured in four standard colors and white and requires the addition of water only. Basically mineral, it is incombustible.
Hl-UTE acoustical plaster DESCRIPTION
Hi-Lite Acoustical Plaster is a highly efficient acoustical
Page 10
plaster with exceptional light reflecting qualities which provides a stipple, or stipple perforated finish. Having a harder surface than Sabinite finish, it is more suitable for side walls above wainscots which require sound con ditioning. It is manufactured in white only and requires the addition of water onlv- .
LIMITATIONS (Both Types)
1. Designed for use on ceilings and areas not exposed to rough usage.
2. To insure best results, acoustical plasters must be applied in strict accordance with manufacturer's directions.
3. Not recommended over radiant heated panel areas, due to low thermal conductivities.
* Trademark Reg. U. S. Pat. Off.
<"> o ^
>'^si
EXTERIOR STUCCO FINISH
r
ORIENTAL EXTERIOR COLORED FINISHES
DESCRIPTION
Oriental Exterior Finish is a factory-prepared stucco for ex terior application over a portland cement-lime basecoat. It requires the addition of water only on the job.
Colors: Pewter Gray, Eggshell Ivory, Sun Tan, Stone Gray, Copper Rose, Alamo Buff, Mission Green, Cascade Green, Pueblo Tan, Indian Coral, Rancho Brown and White.
Integral Coloring--Prevents variations possible where colors are added at site.
Decoration--Requires none. Adaptable to any texture.
FUNCTION AND UTILITY
Factory Prepared--Uniformity in formulation insures endur ance under all weather conditions. Avoids possibility of job mixing errors.
LIMITATIONS
1. Not designed for use as a smooth trowel finish. 2. Requires a portland cement-lime basecoat.
EXTERIOR STUCCO BASECOAT
DESCRIPTION
Exterior stucco basecoat is prepared on the job from portland cement, lime, sand and water and is the basecoat that receives the Oriental* Exterior (colored) Finish.
Strong--Properly mixed and cured, it provides a dense, hard base that will withstand normal wear and usage.
Economical--Use of standard, readily available materials pro vides a low cost basecoat.
FUNCTION AND UTILITY
Exterior stucco basecoat is used for the scratch (first coat) and brown (second coat) over cement block or clay tile, or over sheathing to which Stucco Mesh or self-furring meted lath has been properly applied.
Fire Resistant--Made from portland cement, lime and sand, it will not support combustion.
Weather Resistant--Suitable for normal exposure to climatic variations.
LIMITATIONS OF USE
1. Because of the use of portland cement, each coat requires curing with water after set.
2. Must not be applied in freezing weather or over bases con taining frost.
3. Must not be used on smooth, dense surfaces or over old, un sound stucco unless stucco mesh reinforcement is first properly applied.
INTERIOR PORTLAND CEMENT-LIME PLASTER
CSO16 1160
DESCRIPTION
Portland cement-lime plaster basecoat is prepared on the job from pordand cement, lime, sand, and water.
FUNCTION AND UTILITY
A portland cement-lime plaster is used for the basecoat over cement block, clay tile, or metal lath as a base for ceramic tile or in areas subject to high moisture conditions.
It is incombustible and strong.
* Trademarks Reg, U. S. Pat. 0j}.
LIMITATIONS OF USE
1. Because of the use of portland cement, each coat requires curing with water after set.
2. Must not be used over smooth, dense surfaces, gypsum lath or gypsum block without first securing metal lath to such surfaces.
3. Provisions for relief of setting and drying shrinkage should be made at locations such as ceiling-wall intersections, beams, columns, or fixtures passing through the plaster. Construc tion joints should be provided to avoid excessive continuous areas.
Page 11
PLASTERING SPECIFICATIONS
Notts to Architect Select one or more oj the following base coat plasters, aggregates andfinish coat plasters as desired or required to meet fire-resistant ratings. Where conductivity of the plaster is a factor, see limita tions on Pages 3, 4, and 10.
Where "contact," "furred" or "suspended" lath and plaster ceilings are located under roof deck construction, it is recom mended that the space thus established be ventilated. Such ventilation, with or without vapor barrier and insulation, shall be designed in accordance with accepted engineering practice.
I. SCOPE
Unless otherwise specified or shown on the drawings, all walls and ceilings shall be plastered as herein described.
II. GENERAL PROVISIONS
In cold weather, the temperature of the building shall be maintained in the uniform range above 55 for an ade quate period prior to the application of plaster, while the plastering is being done, and after the plaster is dry. The heat shall be well distributed in all areas, with de flection or protective screens used to prevent concen trated or irregular heat on plaster areas near source. When required, heat shall be furnished by.......................
Ventilation shall be provided to properly dry the plas ter during and subsequent to its application. In glazed buildings, this shall be accomplished by keeping windows open approximately 2" top and bottom (or side pivoted windows approximately 4") to provide air circulation; and. in enclosed areas or buildings lacking openings for natural ventilation by the use of temporary circulators or the air conditioning system.
If glazed sash are not in place and the building is sub jected to hot. dry winds or temperature differentials from day to night of 20 F. or more, openings shall be screened with cheesecloth or similar material.
III. GROUNDS
The minimum thickness of plaster over 16" x 48" gypsum lath, gypsum partition tile or fiber insulation lath, shall be Zi"\ over brick, clay tile or other masonry, it shall be 5/s" thick; over metal lath, the plaster thickness shall be Ye" measured from the face of the lath; and %" over long length gypsum lath. (A greater thickness in grounds may be required for certain fire ratings. See table, page 37, and specify accordingly.)
IV. MATERIALS
Bate Coat Plaster shall be (Structo-Lite) (Red Top Cement Plaster) (Red Top VVood Fiber Plaster) (Bondcrete) as manufactured by the United States Gypsum Company.
Aggregate (for cement plaster) (wood fiber over ma sonry) shall be (Sand) (Perlite) (Vermiculite) meeting the requirements of ASTM Designation C35-53T--"In organic Aggregate for use in Interior Plastering."
Aggregate for job mixed sand float finish shall be a graded silica sand all passing a (30 mesh) (20 mesh) screen.
Water shall be clean, fresh and suitable for domestic con sumption.
Page 12
For (Exterior Stucco Base) (Portland Cement-Lime plaster) the Portland Cement shall comply with A.S.T.M. Designation Cl 50-47, the Lime shall be Mortaseal as manufactured by the United States Gypsum Company, and the Sand shall be clean and sharp and shall meet their requirements of American Standards Association Specifications. A42-2.
Finish Coat Plaster shall be:
a. Gypsum gauged lime putty trowel finish made from Ivory Pressure Hydrated Lime and (Champion Gaug ing Plaster) (Star Gauging Plaster) (Red Top Gaug ing Plaster) as manufactured by the United States Gypsum Company.
b. High strength gypsum gauged lime putty trowel finish made from Ivory Pressure Hydrated Lime and (Structo-Gauge) (Red Top Quick Trowelling Keene's Cement) as manufactured by the United States Gypsum Company.
c. Red Top Gypsum Trowel Finish as manufactured by the United States Gypsum Company.
d. Red Top Gypsum Sand Float Finish as manufactured by the United States Gypsum Company.
e. Oriental Interior Colored Finish as manufactured by the United States Gypsum Company.
f. A job mixed sand float finish made from Ivory Pres sure Hydrated Lime, Red Top Keene's Cement and silica sand.
g. Red Top Cover Coat Finishing Plaster for monolithic concrete as manufactured by the United States Gyp sum Company.
h. (Sabinite Acoustical Plaster) (Hi-Lite Acoustical Plas ter) as manufactured by the United States Gypsum Company.
i. Ornamental run mouldings and Cast enrichments made with Red Top Moulding Plaster and USG Cast ing Plaster as required.
j. Exterior finish coat shall be Oriental Exterior Col ored finish as manufactured by thft United States Gypsum Company.
V. SURFACE PREPARATION
a. Concrete to which Red Top Cover Coat Finishing Plaster is to be applied shall have all laitance and efflorescence removed by dry brushing and the surface scrubbed with naphtha or mineral spirits to remove grease and oil. Brush or spray surface w ' .h cover coat bonder to "neutralize" surface alkalinity and then allow to dry. Patch holes and other surface defects with a paste of Cover Coat.
b. Monolithic concrete to which Bondcrete is to be applied shall be cleaned of all dust, loose particles and other foreign matter. Laitance and efflorescence shall be removed by washing with a 10% solution of com mercial muriatic acid and water, and then cleaning with water to remove all traces of acid. Grease and oil shall be completely removed. Concrete surfaces shall have sufficient roughness to provide proper bond. If surfaces are not rough, they shall be hacked or bush-
*
iJ
PLASTERING SPECIFICATIONS -- CONT,
r
hammered, or dash coated with portland cement grout composed of one part of cement and one and one-half parts of fine sand mixed to a mushy consist ency. Using a stiff fiber brush, the portland cement grout shall be forcibly dashed on the concrete surface with a whipping motion. This coat shall be kept damp for at least two days immediately following its appli cation and then allowed to dry. Before application of the plaster, the surface shall be evenly dampened if necessary to reduce suction.
c. Monolithic concrete surfaces to which asphalt emul sion is applied as bonding medium for acoustical plas ter must be dry, and free of dust, oil, grease or efflo rescence.
d. Unit masonry surfaces that exhibit high suction shall be moderately wetted immediately before plastering.
b. Red Top Cement Plaster and aggregate shall be mixed dry to a uniform color at one end of the box, hoed into the water at the other end and thoroughly mixed to proper consistency.
c. Red Top Wood Fiber Plaster shall be mixed with clean water only and hoed to uniform application con sistency. (For application over masonry aggregate shall be added and dry mixed prior to adding water.)
d. Bondcrete shall be mixed with clean water only and hoed to uniform application consistency.
For mechanical mixing, the mixer shall be cleaned of all set or hardened material before materials for a new batch are loaded. Each batch shall be mixed separately. Ma terial that has partially set shall not be retempered or used. Mix no more material than can be used in one hour.
VI. BASE COAT PROPORTIONS
a. Structo-Lite shall be regular formula for all lath bases and masonry formula for masonry bases.
b. Red Top Cement Plaster for the scratch or first coat over all lath bases in three-coat work shall be mixed in proportion of (one part of plaster to not more than two parts of sand by weight) (100 pounds of plaster to two cubic feet of perlite) (100 pounds of plaster to two cubic feet of vermiculite). Red Top Cement Plaster for all unit masonry sur faces and for the brown or second coat over lath bases shall be mixed in the proportion of (one part plaster to not more than three parts sand by weight) (100 pounds of plaster to three cubic feet of perlite) (100 pounds of plaster to three cubic feet of vermiculite). Red Top Cement Plaster, when mixed for twocoat work over gypsum lath, shall be mixed in the proportion of (one part of gypsum to not more than 2H> parts of sand by weight) (100 pounds of gypsum to not more than !'/> cubic feet of perlite) (100 pounds of gypsum to not more than 2/j cubic feet of ver miculite).
c. Red Top Wood Fiber Plaster. For application over all tvpes of lath, shall be mixed with water only. For masonry surfaces (except monolithic concrete), the scratch and brown coats of wood fiber plaster shall have (one part of sand by weight) (one cubic foot of perlite per 100 pounds) (one cubic foot of vermiculite per 100 pounds) added.
d. Bondcrete shall be mixed with clean water only.
VII. GROUT
Grout for door bucks and flush metal base shall be (Structo-Lite) (Red Top Cement Plaster) and not more than (300 pounds sand) (3 cubic feet of perlite) per bag of plaster.
VIII. MIXING OF BASE COATS
For hand mixing, the mixing boxes shall be water-tight and thoroughly clean of all set or hardened material. All tools and equipment shall be cleaned after mixing each batch. Do not mix more material than can be used in one hour.
a. Structo-Lite shall be mixed with clean water only and hoed to uniform application consistency.
a. For Structo-Lite plaster, no aggregate shall be added. Put the approximate amount of water in the mixer and add the Structo-Lite and mix to proper appli cation consistency, adding water if necessary, and dump the entire batch and use.
b. Red Top Cement Plaster; put the approximate amount of water required in the mixer, then, while the mixer is in continuous operation, add approximately half the amount of aggregate required, add all of the plaster and add the remainder of the aggregate. Mix to proper application consistency, adding water if necessary, and dump the entire batch.
c. For Gypsum Wood Fiber Plaster: add the approxi mate amount of water required. Then add the plaster and mix to proper application consistency. VV'hen sand is added for application over masonry bases, add the water, then the sand, and then add the plaster and mix to proper application consistency.
d. For Bondcrete Plaster, add clean water only, then add the plaster and mix to proper application consistency.
e. For (Exterior Stucco) (Portland Cement-Lime plas ter). the scratch (first coat) shall be mixed in the pro portion of one bag of portland cement; two bags of Mortaseal* (or two cubic feet of lime putty) and seven and one-half cubic feet of sand (approximately 45 No. 2 shovels). For application over stucco mesh or self-furring metal lath, approximately two pounds of fiber or hair shall be added to each mix of the above proportions. The brown coat (second coat) shall be mixed in the proportion of one bag of portland cement, two bags of Mortaseal (or two cubic feet of lime putty) and nine cubic feet of sand (approximately 55 No. 2 shovels).
IX. GROUTING
a. All steel door bucks in 2" solid lath and plaster parti tions shall be fully grouted prior to lathing, leaving a groove to receive the lath.
b. All 2'/5" flush metal base for 2" solid lath and plaster partitions and furred exterior walls shall be grouted. (Provide a V-Groove to receive (Rocklath plaster base) (%" Riblath). (Grout after channel studs are erected for channel stud metal lath partitions.)
CS016 1170
Trademark Reg, V. S. Pat. Of.
Page 13
PLASTERING SPECIFICATIONS -- CONT
X. BASE COAT APPLICATION
a. For two coat work over gypsum lath and masonry, the base (first) coat shall be applied with sufficient mate rial and pressure to form a good bond on the gypsum lath or masonry, as the case may be. and to cover well, and then be doubled back to bring the plaster out to grounds, straightened to a true surface with rod and darby, and left rough, ready to receive the finish (second) coat.
b. For three coat work, the scratch (first) coat shall be applied with sufficient material and pressure to form good full keys on metal lath, and a good bond on gypsum or fiber insulation lath, as the case may be, and to cover well, and then be cross scratched to a roueh surface. The brown (second) coat shall be ap plied after the scratch (first) coat has set firm and hard, brought out to grounds and straightened to a true surface with rod and darby and left rough, ready to receive the finish (third) coat.
c. For 2" solid gypsum lath and plaster partitions, apply a scratch coat of plaster with a maximum 3 hour set, about Vs" thick, to each side of the lath. In no case, shall application of scratch coat to second side of lath be delayed longer than the setting time of the scratch coat applied to the first side. Scratch lightly in hori zontal direction only. After the scratch coats have set firmly and have par tially dried (but not less than 16 hours), the brown coat shall be applied to the unbraced side, bringing it out to within `V' of ground dimension for finish coat to bring overall partition thickness to 2 inches. When brown coat has set firmly (but not less than 3 hours), braces shall be carefully removed from opposite side and brown coat applied to that side in a manner sim ilar to that described for the other brown coat.
d. For 2" solid studless metal lath and plaster partitions apply scratch coat and allow it to set and partially dry. Then apply brown coat to side opposite braces, allow ing it to set thoroughly before removing temporary braces. Next apply brown coat to previously braced side, bringine it out to sufficent grounds to make over all partition thickness 2" when finish coats are applied to both sides.
e. For 2" channel stud, metal lath and plaster partitions apply scratch coat on lath side and allow it to set and partially dry. Then apply back-up coat on channel side applied to full grounds in not less than two opera tions and allow to set. Next apply brown coat on lath side bringine it out to sufficient thickness to make overall partition thickness 2" when finish coats are applied to both sides.
f. For resilient Rocklath ceilings, three coat plaster work shall be used. Apply a full scratch coat, cross rake and allow to set. Then apply brown coat to bring total thickness of plaster to l" over the lath, darby level and leave rough ready for finish coat.
Page 14
g. For (exterior wall furring) (hollow partitions) having long length Rocklath three coat plaster work shall be used to a total thickness of %" over the lath.
h. For column fireproofing total thickness of plaster over lath face shall be (!A") (5/s ") (1") (1 Vs") (1% "). Apply a full scratch coat, cross rake and allow to set. Then apply brown coat to within !4" of thickness required and leave level and rough ready for application of finish coat.
i. Where plaster finish is flush with metal bases, bucks, window frames or similar constructions, both the brown coat and the finish coat should be grooved back at the intersection to reduce possibility of chipping of plaster at these points.
j. At windows, doors and other openings all base coat plaster across head of opening and 12 inches down, each side, shall be cut free of buck, frame or grounds with edge of trowel, after stiffening but before setting, to allow for expansion.
k. Scratch coat of (Exterior stucco) (Portland cement--
Lime plaster) shall be applied in a full
coat, with
sufficient pressure to form a good bond with masonry
surfaces or to force it through and completely embed
the metal reinforcement. Cross scratch and, after set,
damp cure for not less than 48 hours.
Browm coat shall be applied over the dampened
scratch coat in a full %" coat with sufficient pressure
to form a good bond, rodded level and left rough,
using a broom if necessary. After set, damp cure for
at least 48 hours before applying the finish (third) coat.
Damp curing of each coat shall be accomplished by
applying water in a fine, fog spray. Apply only as
much water as is readily absorbed. The frequency of
spraying required will depend on the weather expo
sure, more frequent applications being required dur
ing hot, dry and windy weather.
XI. PREPARATION OF LIME PUTTY
Ivory Finishing Lime shall be mixed with clean water only, using approximately 5 (A to 6 gallons per bag. The putty may be prepared by overnight soak, or by mixing by hand or machine. Run mixer for sufficient time to get a smooth, thoroughly mixed putty which can be used immediately or run into a box for use as required. When stored in a box after mixing, do not permit putty to get crusty or to dry out. Mixer, tools and equipment must be clean.
XII. PROPORTIONS OF FINISH COATS
a. Gypsum gauged lime putty finish shall be mixed in the proportions of 100 pounds of gauging plaster to 200 pounds of dry lime (400 pounds, or 34 gallons, of lime putty).
b. Medium hard STRUCTO-GAUGE-Lime Putty Finish shall be mixed in the proportion of 100 pounds of (StructoGauge) to 200 pounds of dry lime (400 pounds, or 34 gallons, of lime putty).
PLASTERING SPECIFICATIONS -- CONT
c. Hard STRUCTO-G-AUGE-Lime Putty Finish shall be mixed in the proportion of 100 pounds of StructoGauge to 100 pounds of dry lime (200 pounds, or 17 gallons, of lime putty).
d. Medium hard Keene's Cement-Lime Putty Finish shall be mixed in the proportion of 100 pounds of Keene's Cement to 50 pounds of dry lime (100 pounds, or 8/2 gallons of lime putty).
e. Hard Keene's Cement-Lime Putty Finish shall be mixed in the proportion of 100 pounds of Keene's Cement to 25 pounds of dry lime (50 pounds, or 4l/i gallons of lime putty).
f. Keene's Cement-Sand Float Finish shall be mixed in the proportion of 100 pounds of Keene's Cement to 50 pounds of drv lime and 400 pounds of sand (100 pounds, or 8V2 gallons of lime putty and 4 to 5 cubic feet of sand (27 No. 2 shovels of sand).
g. Red Top Gypsum Trowel Finish shall be mixed with clean water only to proper application consistency.
h. Red Top Sand Float Finish shall be mixed with clean water only to proper application consistency.
i. Oriental Interior Colored Finish shall be mixed with clean water only to proper application consistency.
j. Red Top Cover Coat Finishing Plaster, for smooth finish, shall be mixed with clean, warm water only. For sand float finish. 1 /> parts of silica sand by weight to one part of Cover Coat shall be added in the finish coat only.
k. Oriental Exterior Colored Finish shall be mixed with clean water only to proper application consistency.
XIII. APPLICATION OF FINISH COATS
Finish coat shall be applied over a partially dry. level and roughened gypsum base coat. NOTE: Except Cover Coat Finishing Plaster, which shall be applied over Cover Coat Bonder direct to concrete, and Sabinite or Hi-Lite Acoustical Plaster, which may be applied over emulsified asphalt.
The finish coat shall be scratched in thoroughly and immediately doubled back to fill out to a true, even sur face. Thickness to be li6" to Vs"- (Except Acoustical Plaster which shall be V2" thick.)
a. Trowel finishes shall be water troweled during set to provide a smooth, dense surface for decoration, free of irregularities and blemishes.
b. Float finishes shall be floated with shingle, wood, car pet or rubber float to bring aggregate to the surface and produce a finish free of slick spots, cat faces, and other blemishes. In natural color finishes, use water sparingly while floating. Do not use water while float ing colored finishes.
c. Textures shall be applied in such a manner that they will match the sample approved by the architect.
d. Sabinite Acoustical Plaster finish shall be applied according to manufacturer's directions which are here by made a part of this specification.
e. Hi-Lite Acoustical Plaster finish shall be applied according to manufacturer's directions, which are hereby made a part of this specification.
f. (1) Cover Coat shall be applied in one coat over a properly prepared and dry concrete surface by scratching in a thin coat completely covering the concrete and doubling back with a thin coat, level ling out the surface with light trowelling. When the finish has taken up. trowel wdth water to a smooth, level surface. Total thickness not to exceed an average of Vs".
f. (2) Cover Coat shall be applied in two coats over a properly prepared and dry concrete surface by scratching in a thin coat completely covering the concrete and allowing it to set and dry. Second coat shall be then applied, covering first coat evenly and levelling out the surface with light trowelling. When finish has taken up, trowel with water to a smooth, level surface, float with sponge or shingle to a uniformly sandy textured finish. Total thickness not to exceed an average of Vs"
g. Ornamental plaster shall be executed in accordance
with the full-sized details shown on the drawings.
Cornices and moldings shall be run full, straight and
true with molding plaster, using clean cut metal tem
plets conformine to the profiles shown on the drawings.
Lines shall be in alignment, with true intersections,
and accurate mitres at corners and angles. Enriched
ornamental work wliich cannot be run in place shall
be cast with casting plaster in gelatine molds. The
work shall be solidly backed with jute or burlap, shall
be properly reinforced with galvanized iron, and shall
be securely stuck and wired in place with copper wires
not lighter than 16 gauge. All joints shall be carefully
made and neatly pointed so as to be invisible. All
rough spots shall be eliminated with fine sandpaper,
and the entire work left in proper condition, ready for
decoration.
,
h. Oriental Exterior colored finish shall be mixed and applied in strict accordance with the manufacturer's directions. Color and texture to be designated and approved by the architect or his representative.
XIV. PATCHING
Point up around trim and other work. Cut out and patch defective and damaged plaster. Patching of plaster shall match existing work in texture and finish and joinings with plaster previously applied shall finish flush and smooth.
XV. COMPLETION
At the completion of the finish plaster work, clean all plaster from beads, screeds, metal base and metal trim,
leaving work ready for decoration by others. Remove all
plaster rubbish from the building, leaving floors broom
clean. Remove excess material from the job site. Remove
all scaffolding, tools and other equipment from the build
ing and job site.
1
* Page 15
CS016 1172
STATES GYPSUM
CS016 1173
)