Document 8VozwD9MB9Dp8bGEoZLryz1md
4 Ct******* 3. A. l.ardlePersonnel_Minmr____________
0. P. Clatter1 ndu_strlal Hygierut U.A.'J. ASBESTOS SURVEY
inter company ^orreaponaencm
* ct ___________________Aprt 1 2, P?6
Stamping A
Trenton
A i semb ly_______ '-heaitea l_
5 .
* <*"
_
Employee 4
Cltrysler
Indus. jUlat.____Center __
; ***/ -55-02-C0 -17-05-19
Attached for your review Is the laJFeirletftfrygdaeie teplj^ to the U^H Tronic Chemical Pleat Asbestos Surrey, f
hn Attachment
cc: F. A> Burnett G. 0. Benson E. R. Lombard N. McCellua W. M. O'Brien C. A. Settelmeler
0. P. Glazier Industrial Hygienist
CHRYSLB* M12S3
INDUSTRIAL HYCtENE REPLY TO THE LAW TRENTON CHEMICAL PLANT - ASBESTOS SURVEY
GENERAL A. Posting
0SHA Rules and Regulations do not require posclng in areas
where airborne asbestos concentrations are ODfc-X*-exeats of ehe maxims allowable Half. (Cttmmcly 3 flbers/ee, July l, 1976/^ 2 flbers/ecP
if postl^ were required, the slg%pMiticAtio* required by
OSHA would be as follows;
Asbestos Dust Hazard Avoid Breaching Duse
1nr
Wear Assigned Proceceive Equipment
Do Noe Remain In Area Unless
Your work Requires Ic
Breaming Asbestos Dust Hay
Be Hazardous To Your Hceleh
in addition, we believe chat ehe iattaKraftimaf'pofe*, of areas
which have low cir^orne asbeeops fiber conccncracions t^M^gggxacvr
from the j^actlvene3 of OSHA required posting 4riM*Sa7|Shere the
aivbom. coscencraeiuts are, in face,
Ur tio.abfcr
limic.
S. Containers
Industrial Hygiene believes Chat lifecfctng
inaiSs^
for aeOeiCaa eentaininf aaceriafs
to>m*Nrba^mndifle#'bg^
a bomdimg agent, coating* btndegf or other material which will
prevent the release of an excessive airborne concentration of
asbestos fibers (i.e.,'in excess of the maximum allowable limit).
C. Ventilation indltators
industrial Hygiene agrees chat, "w*are feeetara, there should be an tMfrtfck to prevent the operation of equlpmewb-vieSomr-wentliatton."
However, in relation to visible ventilation indicators, we believe that while it Is not difficult for an operator to determine whether an exhaust system is in operation, it may be very difficult for the operator to determine whether or not the system is "performing adequately." Performance evaluations should be the rmepvnstMlify of the epproprlete engineering personn^, who have the required
technical expertise.
D. Housekeeping
Induetrlel Hygiene agrees that aeeiemiou.honaateaepin^standards era necessesy In order co prevent scc*ilntioae of esbeeteefiber*'which could create excessive airborne concentrations upon their dispersion. However# ve believe chat janitorial nenpowe* and schenullag decisions
are'the responsibility of the pleat eneg^ea^*
CHRYSLER SS12*4
Cleaning Methods
while OSHA Rules and Regulacions state that wet .methods snail be used only, "insofar as practicable" Cor the control oi airborne asbestos concentrations, the Corporate Asbestos Review Culde states that, only vacuus cleaning methods and wee sweeping shall be used to collece asbestos fibers.
Work Clothing
Section I9l0.93a (d)(3) of the federal Register stipulates char, "the employer shall provide, and require the use of special cloth ing, such as coveralls or similar whole body clothing,...................... for any employee exposed to airborne concentrations of asbestos fibers which exceed Che celling levml," (10 flbers/cc), Tbutmore strlngene Corporate standard provides chat protective clothing muse be provided and worn by^ell m&ployees exposed to concentra tions of asbestos fibers which.exceed the FeralsslblerExposure Level, (currently 3 flbers/cm). In addition, the Corporat^pn provides disposable aproqp to chose employees who'work in area* where cneir personal clothing may come in contact with loose asbestos dust. It is therefore evident chat Chrysler Chemical has achieved more than simple compliance with the OSHA Regulation, and we believe that the plant has, in fact, provided protective garments for chose employees whose personal clothing may tend to become contaminated with asbestos fibers.
Monitoring Observations
Historically the Industrial Hyglcna Department has attempted to notify the local Union Health and Safety Representative of our survey intentions upon our entry into the plant. We have a^ objection to being accoa^enled by a local unlo^ safety represent ative during regularly scheduled.gybestos survey*, but it should . be noted that the Health amd Safety Memorandum of Understanding provides thae the Health and Safety representative will be excused from his job without loss of pay, only on the following occasions:
1) to accompany Governmental Health and Safety inspectors
2) to accompany Intamacional Union Health and Safaty professionals on plant eours and Corporate Health and Safety professionals on Union requested surveys
The Industrial Hygiene Department has noe provided the local union safety representative with a copy of an individual employee's notif ication of over-exposure to asbestos dust, because there is no agree ment to this effect mentioned in the Memorandum of Understanding.
In regard to the wording of the employee over-exposure notification letter, we do not object to pointing out In the body of the lecter that his exposure exceeded allowable limits, but we do object to providing the employee with the numerical result of the air sample analysis. We believe that the evaluation of air sampling results should be the responsibility of a professional industrial hygienist, who has the knowledge and experience required to put this type of information in the correct perspective.
CHRYSLER OS12S*
H. Receiving of Asbestos Shipments
Industrial Hygiene agrees with Or. Mirer's reeormendatioiu regard ing the receiving of asbestos shipments.
XI FRICTION PRODUCTS BUILDING
A. Weigh-Up Station
OSHA regulations require that asbestos waste must be disposed ot m sealed impermeable bags wnen disposal may produce, "in any reasonably foreseeable use," an airborne asbestos fiber concentmtlon which is in excess of the allowable limit. In lugard to t' e above requirment, Industrial Hygiene feels tnac asbestos waste .hould be disposed of in impermeable bags rather than by attempting t ' control airborne levels by installing local exhaust ventilation for the wascc containers.
In relation to point 42., see our ventilation indic.ncnr comments listed under I. C.
We have no objection to providing covers for transport carts, but it should be noted thac such covers would provide only marginal effectiveness, because they would have to be removed prior to skip hoist loading.
B. Lodige Mixers
Industrial Hygiene agrees with Dr. Mirer's housekeeping and main* tenance recommendations for the Lodige mezzanine. However, we do take exception to point #2. Air sample results have shown that the dust which is seen to escape from the skip hoist when the Loading cart is turned upside down, is composed mainly of non asbestos partlculace. We believe at this time that the use of additional engineering controls to prevent airborne dust at the Lodige skip hoist, would not prove to be a cost effective control measure.
C. Blpel Press
Industrial Hygiene believes that much of the recent increase in employee exposure to airborne asbestos dust at the Blpel work stations is due to haphazard handling of the loose disc brake pad material. If administrative controls cannot reduce che magnitude - of employee exposure tu asbestos dust at the Blpel work stations, additional engineering controls will have to be evaluated. A problem, which should be noted, is that the installation of high capture velocity local exhaust ventilation at the Blpel work stations could result in underweight pads, because of the related loss of the loose disc brake pad material through the exhaust system.
In regard to protective clothing, note our comments listed in Section I, F.
0. O.E.M. Crlnders
Ur have no objection to Or. Mirer's cotiments regarding interlocks
CHRYSLER SS125S
- 4.
and co cha dec*munition of th* operator's noise exposure, but we feel cnac his recommendation chac the plane engineering function report to the health and safety representative Is plainly beyond the scope of the memorandtm of understanding,
E. Saw Area
F. Hairmemlll Meizanine
C. Air Cleaning Equipment
Industrial Hygiene has no objection to Or. Mirer's eoimencs as listed in Sections 11 E., F., and C. of his report.
XXI
CHEMICAL PUNT
A. Oownscairs Weigh-Up Station
As regards posting, please rafer co our comments as listed in Section I, A. Industrial Hygiene has no objaction co obtaining an air sample at the downstairs welgh-up station. This operation Involves the veigh-up of less than one bag quantities of asbestos
on an approximately once per week basis.
B< Storage Area
See our reply as listed In I. H.
C. Mezzanine Weigh-Up Station
Me have no objection to Or. Mirer's comments on housekeeping. See Section I. A., for our posting recommendations.
0. Mixers
We do not concur with Dr. Mirer's posting recommendation (see X. A.). Industrial Hygiene has no objection to the housekeeping and maintenance recommendations.
0. P. Glazier Industrial Hygienist
CHBYStB' 001287