Document 8VL3Vjzap0VxKqKeJo10y4jwk
Heating Systems BoneTM, steel
The Babcock & Wilcox Co.
85 Liberty Street, New York 6, N. Y.
Offices in All Principal Cities
Water-tube Boilers for Stationary Power Plants, and Marine Services. . .Super heaters. . .Economizers. . .Air Heaters. . .Pulverized Coal Equipment.. .Chain Orate. Stokers. . .Oil, Oas, and Multifuel Burners. . .Seamless and Welded Tubing and Piping.. .Refractories.. .Process Equipment.
Heating Systems Boners, steei
Cleaver-Brooks Company
465 E. Keefe Ave., Milwaukee 12, Wisconsin
Cleaver-Brooks Steam Boilers--Self-Contained, Gas Fired. Complete 15 to 500-hn, Oil Fired. Factory Tested 15 to 250 lb psi, Oil & Gas Fired.
STANDARD SIZES
HP 15 30 50 80 100 125 150 200 250 300 350 400 500
Approx, rated capac ity Lbs. Steam Per
515
1050
1725
2760
3450
4300
5200
6900
8800 10500 12000 13800 17000
Hour 212F.
BURN OIL. BURN GAS. BURN OIL & GAS WITH EQUAL EFFICIENCY. Dia
grammatic illustration in cross section representative of the Four-Pass design found in Cleaver-Brooks models. The outstanding feature of the Cleaver-Brooks steam boner is its proven high efficiency . Economy of operation is assured by establishing
an efficient flame and then absorbing the maximum amount of heat in the four passes.
B & W INTEGRAL FURNACE BOILER, TYPE FM Complete Shop-Assembled Steam Plant
This compact, self-contained unit find their steam-load characteristics bet
combines all the desirable advantages of ter suited to a battery of these smaller,
"packaged" steam plants with the serv shop-assembled units than to a single
ice-proved economy and dependability tailor-made installation of the same ag
of larger B&W Integral-Furnace water- gregate capacity.
tube boilers that have been heavy favor The Type FM boiler is available in
ites for years among power companies standardized sizes for steam require
and all kinds of industrial plants.
ments of 2800 to 25,000 lb per hr at pres
The Type FM unit is expressly de sures up to 275 psi. It is unusually sensi
signed for small and medium sized tive to load changes; is fast-steaming;
plants, institutions, and buildings faced features automatic push-button opera
with problems of skilled operating labor, tion with special provisions for safety;
excessive fuel consumption, and costly is suitable for outdoor as well as indoor
maintenance. Even large operators may installations with gas and/or oil firing. 1352
JOB RATED--Each Cleaver-Brooks steam boiler is job rated to meet the steam requirements of your plant. A competent sales engineer helps analyze your load demands and takes into account these conditions:
* Maximum steam requirements in pounds per hour or boiler horse-power.
Whether your steam load is constant or fluctuating, and the degree of fluctuation,
the heating load requirements. `Standby requirements. `Steam pressure
required at point of use. Future growth or expansion of plant facilities Pop
valve settings. Per cent of total feed water returned as condensate. Tempera-
Si ; ,condensate- , * Pressure of make-up water. Type of fuel available.
Electric current characteristics. Space and machinery arrangement. Sug
gested boiler room layouts. Plant altitude above sea level.
6
"
Look for the "CLEAVER-BROOKS" listing under the boiler Section of your classified Telephone Directory.
1353