Document 8RxL41MK61yGxnRgzng9Rzykm

Air Conditioning, Automatic Heating Systems American Gas Products Corporation Division of American Radiator & Standard Sanitary Corporation 40 West 40th Street, New York, N. Y. Gas Fired Air Conditioners The AGP Gas Fired Air Conditioner Type 2-FE has 32 features that place it in a class by itself. Among them are: A Single Combustion Chamber, AGP Thermotor Gas Valve, double inlet, double width, "Sirocco" Type a-c fan with down ward discharge through heater unit. This AGP Conditioner utilizes the highly effi cient counter-flow principle of heat trans fer. The furniture steel jacket of lustrous gun-metal enamel completely encloses all controls. AGP Air Conditioners embody all the improvements of completely auto matic conditioned heating that the finest research laboratories have produced. AGP Air Conditioner Type 2-FE RATINGS--DIMENSIONS--DATA Conditioner Number 2-FE- 4-100 2-FE- 4- 80 2-FE- 5-100 2-FE- 5- 80 2-FE- 6-100 2-FE- 6- 80 2-FE- 8-100 2-FE- 8- 80 2-FE-10-100 2-FE-10- 80 2-FE-12-100 2-FE-I2- 80 AGA Rating AGP Guaranteed Rating Input Btu/hour 100,000 100,000 125,000 125,000 150,000 150,000 200,000 200,000 250,000 250,000 300,000 300,000 Input Btu/hour 90,000 100,000 112,500 125,000 135,000 150,000 180,000 200,000 225,000 250,000 270,000 300,000 Output at Bonnet Btu/hour Output at Register* Btu/hour 72,000 80,000 64,800 72,000 90,000 100,000 81,000 90,000 108,000 120,000 97,200 108,000 144,000. 129,600 160,000 144,000 >80,000 200,000 162,000 180,000 216,000 240,000 194,400 216,000 Conditioned Space Cu Ft 10,600 ^14,700 13,300 18,400 15,800 x22,000 21,100 29,400 26,600 36,600 31,700 44,000 Maximum Fan CFM at 65 F Approximate Shipping Weight Lb 660 920 830 1150 990 1375 1320 1840 1660 2290 1980 2750 1210 1210 1290 1355 1355 1520 1760 1775 2275 2315 2450 2500 For 1X0 Volt, 60 cycle, a-c or for d-c equipment. Note: AGP Guaranteed Ratings are based on thermal efficiency of not less than 80% of the rated AGP Btu Input. Register Output is based on 10% deduction for normal average heat loss in ducts. Conditioned Sfroce indicates the maximum cubic feet of the space which can be conditioned at rated fan CFM to insure quiet operation and adequate air circulation. (See also Page 95S) 886 Air Conditioning, Automatic Heating The Barber Gas Burner Company 3704 Superior Ave., Cleveland, Ohio Address Michigan Inquiries to The Barber Gas Burner Co., of Mich., 4475 Cass Ave., Detroit, Mich. Barber Automatic Jet Gas Burners for Heating and Air Conditioning Equip* ment and Numerous Gas-burning Appliances have won leadership through 20 years of research and manufacture. Used for heating thousands of homes and buildings throughout this country and Canada. Adopted by leading makers of gas appliances. The exclusive Barber jet principle of combustion, other basic advantages of design and numerous recent improvements, have kept Barber Burners apace with modern heating and air conditioning practice. Shown are only a few items from Barber's complete line. Write for No. 37-A catalog and price list. No. S. P.-15 Barber Burner Unit 12 Yi- No. P.U.-160 Burner Unit Barber Gas Pres sure Regulators A.GjL. Approved No. C. U.-90 Barber Burner with Safety Pilot Made in the following sizes: H". H*. M*. *A",\0. IK", 1M". 2*. BARBER BURNERS AND REGULATORS are Adaptable to: Air Conditioning Equipment, High Pres sure Boilers (Tubular and Tubeless), Bakery Ovens, Garage Heaters, Coffee Urns, Hair Dryers, Space Heaters, Floor Furnaces, Clothes Dryers, Water Heaters, Confec tioners' Stoves,Vul canizing Machines, Pressing Machine Boilers, Japanning Ovens, Core Ovens, Banana Room Heaters, Other Ap pliances. Conversion Burner for Round Furnaces or Boilers Made to fit grate diameters from 12 in. to 34 in. Also to fit grates of oblong furnaces and boilers. Supplied with Baltimore Safety Pilot. Listed in the A.G.A. Directory of Approved Appliances. No. 336-B equipped with automatic controls with motor gas valve. Available in "A" series with magnetic gas valve control, "S" series with quick acting gas valve control (for buildings equipped with automatic heat control), and "M" series with manual control. Gas'Burner Specialists offering Engineering Department and Laboratory facilities for Gas Burner problems. 887