Document 8RxL41MK61yGxnRgzng9Rzykm
Air Conditioning, Automatic Heating Systems
American Gas Products Corporation
Division of American Radiator & Standard Sanitary Corporation
40 West 40th Street, New York, N. Y.
Gas Fired Air Conditioners
The AGP Gas Fired Air Conditioner Type 2-FE has 32 features that place it in a class by itself. Among them are: A Single Combustion Chamber, AGP Thermotor Gas Valve, double inlet, double width, "Sirocco" Type a-c fan with down ward discharge through heater unit. This AGP Conditioner utilizes the highly effi cient counter-flow principle of heat trans fer. The furniture steel jacket of lustrous gun-metal enamel completely encloses all controls. AGP Air Conditioners embody all the improvements of completely auto matic conditioned heating that the finest research laboratories have produced.
AGP Air Conditioner Type 2-FE
RATINGS--DIMENSIONS--DATA
Conditioner Number
2-FE- 4-100 2-FE- 4- 80
2-FE- 5-100 2-FE- 5- 80
2-FE- 6-100 2-FE- 6- 80
2-FE- 8-100 2-FE- 8- 80
2-FE-10-100 2-FE-10- 80
2-FE-12-100 2-FE-I2- 80
AGA Rating
AGP Guaranteed Rating
Input Btu/hour
100,000 100,000
125,000 125,000
150,000 150,000
200,000 200,000
250,000 250,000
300,000 300,000
Input Btu/hour
90,000 100,000
112,500 125,000
135,000 150,000
180,000 200,000
225,000 250,000
270,000 300,000
Output
at Bonnet Btu/hour
Output at
Register*
Btu/hour
72,000 80,000
64,800 72,000
90,000 100,000
81,000 90,000
108,000 120,000
97,200 108,000
144,000. 129,600 160,000 144,000
>80,000 200,000
162,000 180,000
216,000 240,000
194,400 216,000
Conditioned Space Cu Ft
10,600 ^14,700
13,300 18,400
15,800 x22,000
21,100 29,400
26,600 36,600
31,700 44,000
Maximum
Fan CFM
at 65 F
Approximate Shipping Weight Lb
660 920
830 1150
990 1375
1320 1840
1660 2290
1980 2750
1210 1210
1290 1355
1355 1520
1760 1775
2275 2315
2450 2500
For 1X0 Volt, 60 cycle, a-c or for d-c equipment. Note: AGP Guaranteed Ratings are based on thermal efficiency of not less than 80% of the rated AGP Btu Input. Register Output is based on 10% deduction for normal average heat loss in ducts. Conditioned Sfroce indicates the maximum cubic feet of the space which can be conditioned at rated fan CFM to insure quiet operation and adequate air circulation.
(See also Page 95S)
886
Air Conditioning, Automatic Heating
The Barber Gas Burner Company
3704 Superior Ave., Cleveland, Ohio
Address Michigan Inquiries to The Barber Gas Burner Co., of Mich., 4475 Cass Ave., Detroit, Mich.
Barber Automatic Jet Gas Burners for Heating and Air Conditioning Equip* ment and Numerous Gas-burning Appliances have won leadership through 20 years of research and manufacture. Used for heating thousands of homes and buildings throughout this country and Canada. Adopted by leading makers of gas appliances. The exclusive Barber jet principle of combustion, other basic advantages of design and numerous recent improvements, have kept Barber Burners apace with modern heating and air conditioning practice. Shown are only a few items from Barber's complete line. Write for No. 37-A catalog and price list.
No. S. P.-15 Barber Burner Unit 12 Yi-
No. P.U.-160 Burner Unit
Barber Gas Pres sure Regulators A.GjL. Approved
No. C. U.-90 Barber Burner with Safety Pilot
Made in the following sizes:
H". H*. M*. *A",\0. IK",
1M". 2*.
BARBER BURNERS AND REGULATORS are Adaptable to: Air Conditioning Equipment, High Pres sure Boilers (Tubular and Tubeless), Bakery Ovens,
Garage Heaters, Coffee Urns, Hair Dryers, Space Heaters, Floor Furnaces, Clothes Dryers, Water Heaters, Confec tioners' Stoves,Vul canizing Machines, Pressing Machine Boilers, Japanning
Ovens, Core Ovens, Banana Room Heaters, Other Ap pliances.
Conversion Burner for Round Furnaces or Boilers Made to fit grate diameters from 12 in. to 34 in. Also to fit grates of oblong furnaces and boilers. Supplied with Baltimore Safety Pilot. Listed in the A.G.A. Directory of Approved Appliances. No. 336-B equipped with automatic controls with motor gas valve. Available in "A" series with magnetic gas valve control, "S" series with quick acting gas valve control (for buildings equipped with automatic heat control), and "M" series with manual control.
Gas'Burner Specialists offering Engineering Department and Laboratory facilities for Gas Burner problems.
887