Document 8Rw3pkv0GKab2zxGxBZO97xqd
104
IN THE UNITED STATES DISTRICT COURT FOR THE NORTHERN DISTRICT OF ILLINOIS
EASTERN DIVISION
THE UNITED STATES OF AMERICA, Plaintiff,
vs . OUTBOARD MARINE CORPORATION AND MONSANTO COMPANY,
Defendants.
)
) )
) ) No. 78 C 1004
) ) ) ) )
May 28, 1981, 1:30 o' clock p,m.
The deposition of ROBERT E. KELLER resumed p ursuant to noon recess at the offices of Kirk land & Ellis, 200 East Randolph Drive, Chicago Illinois 60601, before Thea L. Urban. PRESENT:
MR. JAMES T. HYNES, MS . ROSEANN OLIVER, MS . JOANNA NEW, MR. BRUCE A FEATHERSTONE, MR. ROBERT E. SHAPIRO.
TU L.
n
Certified RkcrtRnd Reporter
I3^r Soutk j_a Resile Rtreet
(fRic^co, li'inoK 60603
STLCOPCB4026695
Keller
direct
105
ROBERT
E.
KELLER,
called as a witness herein, having been previously
duly sworn, was examined and testified further as
follows:
DIRECT EXAMINATION (Resumed)
BY MR. HYNES:
Q Doctor, you said earlier that once your
department got on line with the new technology, the
gas chromatograph and the mass spectrometer, you
started doing various projects dealing with PCBs.
You mentioned two, I believe: Biodegradation work
and solubility.
Was it solubility in water, was that
it?
A Correct. O These were considered to be non-routine
type analytical-type work using that technology, is
that correct?
A Yes .
Q Other than these two projects, were there
any other non-routine type work you did using GC/MS
dealing with PCBs between 1969 approximately when the
technology was on line and 1973?
A Yes.
T~bea [_. Urban
Cje^-tReJ RkortSianJ Reporter
34 Cc
I_o R-alle Rtreet
a C(7.io, ( f f i no($ 60603
STLCOPCB4026696
Keller
direct
106
Q Could you just briefly state what the other
analyses were and this is on just PCBs .
A Yes .
MR. FEATHERSTONE:
What is the relevancy to
unknown tests? We are about to hear the testimony,
perhaps if I let it go forward. Are there species
that somehow are relevant to your case, Mr. Hynes?
MR. HYNES:
Well, biodegradation is one. I am
talking non-routine.
MR. FEATHERSTONE:
I am not sure we know what
non-routine means.
MR. HYNES:
Special, I said similar in type to
the biodegradation or the water solubility tests and
that general analysis.
MR. FEATHERSTONE:
All right. Go ahead. Doctor.
BY THE WITNESS:
A I think my answer was yes on that.
BY MR. HYNES:
Q What were these other types of projects?
A The support to the business group and Medical
Department, our clients, on certain toxicology studies
involving animals, measurement of PCB residues.
MR. FEATHERSTONE:
In test animals?
THE WITNESS:
Test animals.
Tkeo L- Uf'txan
(^ertiNed
[Reporter
154 ^~)Outn [_a
Street
Oic r>o, iifinoi? 60603
STLCOPCB4026697
Keller
direct
107
BY MR. HYNES:
Q Just briefly, your work on there was measuring
the levels and types of PCBs within the test animals,
is that correct?
A Correct.
Q You obviously didn't have anything to do with
toxicology or any related field like that?
A Correct.
Q Any other types of work that you did of this
nature?
MR. FEATHERSTONE:
On PCBs.
BY THE WITNESS:
A No, I think those are the only ones.
BY MR. HYNES:
Q As to the v/ork you did on biodegradation,
was that more than one study?
A Yes .
Q How many studies, doyou recall,that were
involved?
A A sizeable number, and I can't give you an
answer except to say more than five.
Q What was thespecific subject matter or
task as to each of these studies, as best you recall?
MR. FEATHERSTONE:
Wait. May I have that question
1_ LWxan
----------------------------------------------------------------------------------------------------------------------------------Certified Ckortlicind Reporter _____________ 134 Soutk |_a Rciile Rtreet
CRcci^o, iflinoK 60603
STLCOPCB4026698
Keller
direct
108
back?
.
MR. HYNES:
Let me do it this way --
BY MR. HYNES:
Q You said there were many studies, more than
five, you are not sure how many. Was there a distinct
subject matter or area you were investigating in each
of those studies? MR. FEATHERSTONE:
Could you respond to that?
/
THE WITNESS:
Yes.
MR. FEATHERSTONE:
All right.
BY THE WITNESS:
A Yes .
BY MR. HYNES:
Q And as best you can recall, what were the
various subject matters of each of these studies?
A One principal series of projects were in
volving, looking at the Aroclor 1200 Series.
Q Looking at biodegradability ofAroclor 1200
Series, is that correct?
A Correct.
Q What other areas did youinvestigate other
than the Aroclor 1200 Series?
MR. FEATHERSTONE:
You mean products?
BY MR. HYNES:
--------------------------------------------- ---------- -------------------------------------------------------------------------
|_- Urban
(^ertiOcd
|I?eporter
1.54 |_o Street o, jllmci? 60603
________
STLCOPCB4026699
Keller
direct
109
Q Products or subject matters of various
studies.
MR. FEATHERSTONE:
Why don't you tell us what
you mean by subject. If the tests are on biodegrada tion, they would have to be on "products or at least
on chemicals. I don't know what else.
BY MR. HYNES:
Q Is that how it was broken down, you did
biodegradation studies on different products or dif
ferent chemicals?
A Yes.
Q
One of theproduct
groups wasthe Aroclor
1200 Series?
A Yes.
Q What were the other product groups you did
biodegradation studies on?
A We worked on manyproduct groups relative to -
MR. FEATHERSTONE:
He is talking about PCBs,
Doctor.
THE WITNESS:
Okay.
BY MR. HYNES:
Q PCBS.
A I was going to conclude that of other organic
products but this was the principal thrust on PCBs,
""Plieo 1_. Certified Rk ortRnd Reporter
134 ^douth |_a Calle Rtreet a [caao, Illinois 60603
STLCOPCB4026700
Keller
direct
110
was the 1200 Series.
Q So you did biodegradation studies on other
products which did not contain PCBs?
A Correct. Q To the best of your knowledge, the biodegra
dation work which you did do that related to PCBs was only the study on the 1200 Aroclor Series?
A Correct.
Q
Who set upthe protocol
for thetesting of
the 1200 Series of Aroclors on biodegradation? A That was set up in our analytical group.
Q Those are the people working for you?
A Yes. Q Can you just briefly explain the purpose of
the study, what you hoped to accomplish by it?
A It was directed toward developinginformation
needed by the clients, the business groups and the
Medical Department to better assess PCB products in
terms of their usage and the presence in the environ
ment. MR. FEATHERSTONE:
Better assess the state of the
product, of the PCBs in the environment?
THE WITNESS:
Yes.
BY MR. HYNES:
T^ec L- U^n
Ce-tined
orthand Reporter
134 |_a R^!!e Street
a i Co o o, Illinois 60603
STLCOPCB4026701
Keller
direct
111
Q When was it first determined that biodegra- . dation --
MS . OLIVER:
Could you read back that last answer?
(Record read.)
BY MR. HYNES:
Q When was it first determined that biodegra
dation studies should be done on the Aroclor 1200
Series ?
A For our group, Applied Sciences?
Q Yes . A This was in late 1960 -- 1969, possibly 1970.
Q By whom was that determination made that the testing should be done?
A By the business group and Medical Department.
Q Would the business group be the Functional
Fluids ?
A Yes .
Q Am I correct that they then requested your group to undertake studies?
A Right.
Q Was this direction given personally to you
to undertake this testing?
A I can't reconstruct how this was communicated
from the business group.
TU |_. ----------------------------------------------------------------------------------------------Certified Ckorthond Reporter
154 Routk |_a Real ie Clncdiro, |hinois 60603
--------------
STLCOPCB4026702
Keller - direct
112
Q Could you just briefly explain the work you
did, the work your group did on the biodegradation
studies on the Aroclors?
A The first task, you understand that this was
a new technique for Applied Sciences. And the first
task was to set this up as an operational technique
and one of the first projects needed was to develop
the technique which would be applicable to PCBs.
MR. FEATHERSTONE:
You are talking about bio
degradation technique?
THE WITNESS:
Biodegradation technique for PCBs,
the reason for that being biodegradation technique had
been used within Monsanto Company approximately from
the late '50s, possibly early '60s, in another division
of the company at that time, the Inorganic Chemicals
Division. The technique there was used for research
groups dealing with surfactants, products for the soap
industry, et cetera.
These were water soluble types of
materials which could be used more readily in a semi-
continuous activated study involving water soluble
products.
Applied Sciences was to develop techniques,
biodegradation techniques which would handle quite
______________________
~The^ l_ bJrOn
Citified 5^ortli3nd Reporter -------------------------------------------------------------------134 Routk \_a Salle Street C^niCJic?c, Illinois' 60603
STLCOPCB4026703
\
Keller
direct
113
insoluble materials su ch as PCBs, so that work was
concurrent with settin g up the physical equipment, the
hardware necessary to do this, and concurrent with
this it was necessary for us to train out of our area,
Applied Sciences, peop le with competency to carry out
work of this type.
BY MR. HYNES: Q So the first ta sk was to *" --
A To become op era tional, Q It was an ac cep ted techn ique w i thin the
Organic Chemicals Divi s io n for tes ting b iodeg radation
and that technique had to be modif ied so that it could work, be able to study bi degradation of inso luble
chemicals like PCB?
MR. FEATHERSTONE:
He didn't tes t i f y th at a
technique existed with th e Organic __
MR. HYNES:
I th ought I said Inorg anic.
MR. FEATHERSTONE:
And the technique fo r water
soluble compounds.
BY MR. HYNES:
Q The technique for water soluble compounds,
it was your group's task to modify a technique so you
could use it for insoluble chemicals such as PCB, is
that correct?
Theo I_ Urban Certified ortkond [Reporter
134 Soul!, La SLIe Street
(LLoono, Illinois 60603
STLCOPCB4026704
Keller
direct
114
A Yes .
Q Once that task was accomplished, what was
the next step in your study?
A To apply it to the PCB-types of products.
Q Did you take as part of your study each
Aroclor compound and study each of them independently
to determine the biodegradation qualities of each?
A Yes, I would like to add one comment as to
what preceded your question of a study. That was a
methodology beyond the biodegradation test. To be able
to follow what happens with the biodegradation test,
you have to be able to follow the fate of the chemicals
under study and to do that required special methodology
for the PCB-type materials.
And fortunately this was made possible,
again, with the GC, gas chromatography, mass spectrometry
techniques which were coming along nicely and were being
put in place, so this made it possible and this is what
we concentrated on secondly after the equipment was
installed, to be able to monitor and assess what came
out of the PCB studies. And then we moved into a
study of the Aroclor 1200 Series.
Q Once the technology was operational and the
methodology was operational, at that point, I think you
L. U rbctn
-----------------------------------------------------------------------------------------------(^e^tiped
[Reporter
134
f__a ^ociifo Street
C~3' 'C<?GJC. jilinot? 60603
______
STLCOPCB4026705
Keller
direct
115
said then each Aroclor compound was separately analyzed
to determine the biodegradation qualities of these?
A Of these, each Aroclor product?
Q Each Aroclor product.
A Which is a mixture of PCBs.
Q Am I correct that you did not analyze the
Aroclor chemical but rather the end product which was
sold as analyzed, each end product?
A No, that is not correct.
MR. FEATHERSTONE:
Aroclors themselves are end
products.
BY MR. HYNES:
Q The Aroclor will be a 1242 or 1248, that is
what was analyzed?
A Correct.
Q
And do yourecall
if each Aroclor Monsanto
produced was in fact analyzed?
MR. FEATHERSTONE:
He said Aroclor 1200 Series.
Is that the limitation?
BY MR. HYNES:
Q 1200 Series,I'm sorry.
A Yes.
Q Do you know if any other Aroclors other than
the 1200 Series were analyzed?
T^eo L -----------------------------------------------------------------------------------------------RhortRnd Reporter _
134 Routk 1_a Resile Rtreet a icoro, I ! i i noi 60603 to "7QO Z Z 7. O
STLCOPCB4026706
Keller
direct
116
A Yes. Q Which were those, if you recall?
MR. FEATHERSTONE:
Were these other than PCB
Aroclors ?
THE WITNESS:
Yes.
BY MR. HYNES:
Q I am just talking about PCB Aroclors.
A No, if it is only PCBs, no.
MR. FEATHERSTONE:
It is only PCBs. All the PCB
Aroclors were tested for biodegradability, is that
correct?
THE WITNESS: Correct, right.
BY MR. HYNES:
Q Didyou also analyze, would PCT, poly
chlorinated terphenyl, be included in the 1200 Series
of Aroclors?
A No. Q Were any of those found that you can recall?
MR. FEATHERSTONE:
Why is that a pertinent question,
Mr. Hynes? MR. HYNES:
I think it is a pertinent question
because the PCTs were also sold to Johnson Motors for
a period of time as a substitute, as I understand it,
for the PCBs and I think in a product case here if
Thee |_. ITTen -----------------------------------------------------------------------------------------------Cerl.UeJ SticrtKjncI Reporter _________
IZ^ South |_ S^'le Street Shiceec, | I!ino>s 6C603
STLCOPCB4026707
there is any relationship between those two products
in terms of analyses, end results and the like, I just
want to know if there is any information that PCTs
are related in this field of biodegradation to PCBs.
MR. FEATHERSTONE:
PCTs are different compounds
from PCBs.
MR. HYNES:
They are similar compounds.
MR. FEATHERSTONE:
But they are different compounds.
MR. HYNES:
Fine, but similar.
MR. FEATHERSTONE:
And the similarity that you
have said in terms of relevancy is that we happened
to sell PCT fluid to Johnson Motors and you have not
complained of PCTs anywhere.
MR. HYNES:
I think it is relevant as to the
techniques utilized for determination of whether the
PCBs and/or the PCTs are safe, are a problem in the
environment.
MR. FEATHERSTONE:
Are you complaining about
PCTs? MR. HYNES:
No, but I think the work that is
involved in PCTs might be relevant to see if indeed
all the work that was done on PCTs was adequate in
terms of warning and harm and the like.
MR. FEATHERSTONE:
I don't see the relevance of
TU
I_jrktfir
Certified
onj [Reporter
154 1_a lie Street
o 1 coo:, | I i moif 60603
312 - 782-3332
STLCOPCB4026708
Keller
direct
118
how the --
,
MR. HYNES:
I just want to find out at this point
if the PCTs were analyzed and that biodegradation
studies were done as with the 1200 Series of Aroclors
with PCBs.
MR. FEATHERSTONE:
Since I take the position the
question is wholly irrelevant to your issue of the
lawsuit, we are not going to answer this question.
MR. HYNES:
You are not going to answer any
question on PCTs?
MR. FEATHERSTONE:
On the biodegradability of
PCTs
MR. HYNES:
We can certify that.
MR. FEATHERSTONE:
That was your question,
MR. HYNES
Fine
BY MR. HYNES:
Q As to the analysis you did on biodegradability,
the 1200 Series of Aroclors, and I will say PCBs, just
briefly explain, did you use the same technique in
analyzing each of the different Aroclors?
A Yes.
Q Other than the product itself under analysis,
was there anything different in any of the work done
on any of these products in terms of technique,
"{"heei 1_. IJrtjein ____________________________________________________
134 Routk 1_Rtille Street a icoac, Illinois 6C603
STLCOPCB4026709
Keller
direct
119
methodology?
A No.
Q Could you explain just briefly then the
series of steps that you went through to determine the
biodegradability of each of these products and I don't
mean 1242, but since you used the same technique, the series of steps you used to determine the biodegrada
bility of the products.
A The test is asemi-continuousactivated
sludge test which simulated a secondary sewage disposal plant operation. It involved in the laboratory taking microorganisms from an actual sewage disposal plant, bringing them into the laboratory, putting them into our laboratory system, feeding these microorganisms
with a nutrient-type growth to maintain their activity and then periodically charging the compound, in this
case PCBs, in question to this system. Then at predetermined intervals, such
as 24 hours or 48 hours, withdrawing a sample from the
system and analyzing it for residual PCB under study
and comparing it to the amount charged. The amount lost is used as a measure of
biodegradability, normally reported as percent in a
24 or 48-hour period.
|_. Ur(son ------------------------------------------------------------------------------------------------------------------- Certified Clio'-tCnd Reporter -
1^4 Soolk 1_a Ralle Rtreet
tin 7 An . t t t no icaao, Illinois 60603
STLCOPCB4026710
Keller
direct
120
MR. FEATHERSTONE:
You say amount charged. You
are referring to PCBs put into the test?
THE WITNESS:
Right.
BY MR. HYNES:
Q Was there a standard nutrient used for these
microbes ?
A Yes.
Q Do you recall what it was?
A No, I don't recall. Q This is a standard technique used for each of the different Aroclors, is that correct?
A Correct. Q Am I correct in assumingthat the types of microbes, the types of nutrientsused, the intervals,
samples were drawn and the like were all constant throughout each of the tests of the different Aroclors?
A Correct.
(Mr. Shapiro left the deposition room.)
BY MR. HYNES: Q How long did this study or this series of
studies take place once you had the methodology and technology in place until you came up with the final conclusions or your conclusions as to the biodegradability
n
Ce-t.f,eJ
J [Reporter
13*4 |_a ^tTeet
a \cooo, Illinois 60603
STLCOPCB4026711
of the compounds? A Normally from weeks to months' duration. Q From weeks to months depending on which
Aroclor you were studying at the time? A Correct, correct. Q Approximately how long did it take from be-
ginning to end to analyze the whole 1200 Series? A Approximately one year. Q Do you recall v;hat the lowest chlorinated
Aroclor was, what the percentage of chlorine was? A Yes . Q Which was it? A 1221. Q What was the highest? A 12 G 0 . Q That is 21 percent chlorine, 60 percent
chlorine? A Yes . Q What were the conclusions which you drew in
terms of the biodegradability of the Aroclors? A We found that the rate of biodegradation
decreased as the chlorine numbers increased in the PCBs. To put it in further perspective on a
relative basis, Aroclor 1221 biodegraded faster than
---------------------------------------------------------------------------------------------
T^ea
l_Jrb<3n
RertifieJ Rkor^Rnd Reporter
134 Rouik [_a
f fe
a icooc. Illinois 60603 710 - 70_7770
_
STLCOPCB4026712
Keller
direct
122
the next Aroclor up the line all the way to 1260.
Q In your study did you use any standard or
set any benchmark where you determined that there was
significant biodegradation at some point below this;
it was significant above this; it was insignificant?
A What is significant?
Q That is what I mean. Did you determine
yourself in this study that there was some point you
would consider biodegradation significant or insig
nificant?
MR. FEATHERSTONE:
Was that the function of your
group, I guess is the preliminary question.
BY THE WITNESS:
A Let me answer the question this way:
From our group and our responsibilities,
we had determined that the result was significant
from the standpoint of our method accuracy, biodegra
dation technique accuracy. Once we felt that the
answers were reliable with limits put on it as to
accuracy, then these were turned over to our client,
the business group or Medical Department for their
judgment as to further assessment.
BY MR. HYNES:
Q Am I correct in assuming that your signifi-
|_. Urlx,n
Certified
ortkond Reporter
IM Soutk Ls Salle Street
H!;TM;, 60603
STLCOPCB4026713
Keller
direct
123
cance was the statistical significance of your findings
in terms of accuracy?
A Correct.
Q But your group did not set any significance
levels in terms of analyzing the data, saying below
this point it is insignificant biodegradation?
A Correct.
Q Do you know if anyone in the business group
or Medical Department ever made that determination
that the biodegradation at some point was insignificant
in any of these products?
MR. FEATHERSTONE:
Made that precise finding
that it was insignificant or that it was -
MR. HYNES:
No, was there a determination made
to his knowledge by either the Medical Department or
business group that biodegradation up to a certain
level of the product was insignificant.
BY THE WITNESS:
A I don't know how they used this information.
MR. HYNES:
All right.
BY MR. HYNES:
Q Do you recall the ranges of biodegradation
in the productsl221 and 1260?
MR. FEATHERSTONE:
You mean the precise findings?
--------------------------------------- :------------------------------------------------------
""T^eo |_. l^_Jrl^n (3erbfed Shorthand [Reporter
134 South [_a S*He Street
(^kic^no, Illinois 60603
_
STLCOPCB4026714
Keller
direct
124
BY MR. HYNES:
Q The percentages. You said 1221 was the
highest percentage of degradation, 1260 was the lowest.
Do you recall what the range was in
terms of percentage?
MR. FEATHERSTONE:
He didn't say that. He said
1221 biodegraded more quickly than the next Aroclor.
MR. HYNES:
He said it was expressed in a per
centage of biodegradation.
MR. FEATHERSTONE:
Over a period of time.
MR. HYNES:
Yes.
MR. FEATHERSTONE:
But your question does not
take into account time, only the percentage.
BY MR. HYNES:
Q The biodegradation standard you used was
biodegradation over a period of time, is that correct?
A Yes.
Q Using your standard then, your methodology,
do you recall what the background was in terms of
time, the measurements you used? Was it a standard
interval that you used throughout the tests?
A Either 24 or 48-hour period.
Q So those were the only time standards that
you used?
"Tketf 1_. Urlscin ------------------------------------------------------------------------------------------------------------------C-t'flJ ortSnd Reporter -----------------
!54 Souif, |_d> SJie Street {Rk iccadio, liiinoi? 60605
STLCOPCB4026715
Keller
direct
125
A To mv best recollection
Q Do you recall what the range of the bio
degradation at the 24-hour level was between the
products?
A You are asking for absolute percent?
Q Best you recall, what the percent was of
biodegradation.
MR. FEATHERSTONE:
Could you do it?
BY THE WITNESS:
A 1221 which was the most degradable, in a
typical 48-hour period, biodegraded -
BY MR. HYNES:
Q I said the 24-hour first.
A
All right.
I will say forthepurpose of
our continuing discussion, I think all these were done
on a 48-hour basis percent and 48 hours, percent in
48 hours.
Q All right.
A And the 1221 biodegraded in the range of
50 to 60 percent in 48 hours. And this proceeded to
decrease throughout Aroclor 1200 Series up to the 1260,
which degraded at a slower rate in the order of few or
more percent, 5 to 10 percent.
Q I think you stated when you were setting up
---------------------------------------------------------------
-------------------------
ea L. U rl^n
C^er-hNeJ
Reporter
I 36 Soutk ^_a
Street
(liinci? 60603 ~i q o t ~z t n
-
STLCOPCB4026716
Keller
direct
126
the techniques and the methodology to measure the
.
biodegradability that an important part of this was
to be able to follow the fate of -- I am not sure if
it was a chemical or the product, the compound. You
needed to follow its fate and that was where the
mass spectrometer came in.
I am kind of paraphrasing what you said.
Could you explain what you mean by it was important to
determine the fate of the product in terms of bio
degradability?
MR. FEATHERSTONE:
No, you have two ideas con
fused. From my notes one is the purpose of the pro
ject was to better assess the fate of PCBs in the
environment. The second is they needed the GC/MS
unit to monitor the biodegradation of PCB products.
MS. OLIVER:
Beyond the biodegradation, you
needed the mass spectrometer to be able to follow the
fate of the chemical in your biodegradation study of
the chemical.
BY THE WITNESS:
A That methodology is what is required to come
up with a biodegradation figure.
BY MR. HYNES:
Q That is what I just don't understand.
"T^eo |_. -----------------------------------------------------------------------------------------------Certified ortRnd Reporter
134 1_a ROfle Street a tcoao, Illinois 60603
STLCOPCB4026717
Keller
direct
127
Following the fate of the chemical, you mean follow the fate,here is the PCB molecule with certain per centage of chlorine and after it biodegrades for 48
hours the fate is the measurement of how much less chlorine is on the molecule, is that what you mean by
the fate of the molecule? A No. My interpretation if fate was brought
out here -
MR. FEATHERSTONE:
Well, your meaning was?
BY THE WITNESS:
A My meaning was that the business unit and the Medical Department were concerned about what hap pened to PCB products in the environment. They were
directing their efforts to getting any and all informa tion possible together to better assess what happens
to these products and to make future judgments and
appropriate actions relative to these products.
BY MR. HYNES: Q In terms of determining the fate, in terms
o f the methodology you heid established,. and maybe I am just missing what the definition is that you are us iLng of biodegradation. Let me do it this way:
What do you mean by biodegradation.
what is your definition of that?
Thee 1_.
Cjer'ti f-ied ^ko^tk^ind ["Reporter
IM ^p-ouik j_a
Street
(^k\coao, Illinois' 60603
31? - 780-333?
STLCOPCB4026718
Keller
direct
128
A It is the rate reported as percent at which
the PCB disappears in a prescribed period of time, in
this case 48 hours, in the presence of microorganisms such as those found in a secondary sewage disposal plant.
Q In terms of the measurement then, if you
start out with a quantity of 100 units of whatever the
unit of measurement, here of PCBs, at the end of 48
hours' measurement it biodegrades 20 percent, that
means then there are 80 units of PCBs remaining?
A Correct. Q That other 20 percent then is no longer con
sidered to be a PCB, is that correct?
A That is correct. Q And am I correct that it breaks down into
its component parts, chlorine?
A Correct. Q It breaks down to some extent into its com
ponent parts? A Correct. Q As to this breakdown into its component parts,
was part of your test to measure what those parts were
that it broke down into?
A We directed our efforts toward measuring
C^ertiied 134
|__. )r\x?n
[Reporter j_a Illinois 60603
STLCOPCB4026719
Keller
direct
129
residual starting material as opposed to measuring
intermediate final degradation product from the bio
degradation .
Q It was not part of your study to measure
what happened to the percentage of PCBs broken down
into component parts?
A Correct.
Q Did your group ever conduct a measurement of
that type at any other time?
A It is possible the group that the biodegrada
tion was in. Applied Sciences, carried out a study of
this type and I was not aware of it. To my knowledge,
this was not done.
Q
On the biodegradationstudy,
your function,
your involvement in that was doing a study, coming up
with the percent of biodegradation of these products.
Is that where your responsibility stopped? Your results
were then sent to the Medical group. Functional Fluids
and they were responsible for taking any action they
felt appropriate on the results?
A Correct.
Q Were you ever involved after your results
were concluded, were you ever involved in any meetings
or discussions or receive any correspondence from anyone
Thee? |_. Urban
----------------------------------------------------------------------------------------------------------------------------------- Sertified Shorthand Reporter ________ 134 Routn )_a Salle Street
(^hiCr?r>o, I llmot? 60603
STLCOPCB4026720
Keller
direct
130
outside of the Analytical Department concerning any
action taken as a result of your biodegradation studies?
A No.
Q Do you know of any action which was taken as
a result of your study by Monsanto?
A No .
Q In setting up the technique and the method
ology for conducting the biodegradation test, why was
an activated -- you said it was semi-continuous
activated sludge test. Why was the medium of sludge
chosen for this methodology?
A It was the most ready source of microorganism
of that type that would permit a biodegradation study
that was available to us or to any who carried this
out in terms of a test that had a chance of showing
you what you wanted to show with materials biodegradable
over a range and not water soluble.
Q To your knowledge, was there any environmental
reason why activated sludge was chosen as the medium?
MR. FEATIIERSTONE :
Other than testing bio
degradability of the products?
MR. HYNES:
Right.
MR. FEATHERSTONE:
Did you understand that
question?
T^eo j_. U-rlxsn C^ertVied ^korthcpnj [Reporter
^34 'y-outn |_a ^cille Street | I line.;. 60603
STLCOPCB4026721
Keller
direct
131
THE WITNESS:
Yes.
MR. FEATHERSTONE:
You are doing better than I am.
MS. NEW:
Me, too.
BY THE WITNESS:
A The reason it was chosen is it was expedient
to come up with relative biodegradability figures in
the presence of microorganisms.
BY MR. HYNES:
Q What I'm getting at is I assume that from
what you are saying, activated sludge test, I think
you said it simulates a sanitary treatment plant,
whatever the medium that would be found in a sanitary
disposal plant, sanitary treatment plant?
A Correct.
Q My question is was there any environmental
concern that you know of or that was expressed to you
that that medium should be chosen because of potential
environmental problems of PCBs getting into sanitary
treatment plants?
A No.
Q Your biodegradation study results, do you
know if that was ever published in any type of a
scientific journal or sent out to the scientific com
munity as a whole at any point?
T"^ec |_.
Cje'-'tified ^Hortr, ijnd ["Reporter
!36 ^ouin {_a.
He ^t'neet
O; 60603
STLCOPCB4026722
Keller
direct
132
A We made available what information we had to
interested parties.
Q Basically someone who requested information
like that, you would make it available to them?
A Yes, correct.
Q But it was not something published in
Science Magazine or something of that nature?
A Correct.
Q You also mentioned the water solubility test
which was conducted by your group. When was that study
first proposed?
A Late 1969 or early 1970.
Q Approximately the same time period as the
biodegradation study?
A Yes .
Q Were these two studies related in any way?
Did you use the information from one to the other or
were they independent studies?
A Related.
Q How were they related?
A Because we needed solubility information for
PCBs which were very low in solubility to properly
design the precision testing in terms of, for example,
how much material could be charged and we had to be
~[Lec> 1_. UrLwn
(Le^bNed LLertkand ["Deportee 134 Loud La LLUe Ltreet LL'Caac, { !! i n o t 9 60603
-----------------
STLCOPCB4026723
Keller
direct
133
sure it would remain in a soluble solution.
This was a key reason for determining
solubility at very low levels for our new GC/mass
spectrometer because it was an important part of de
signing the biodegradation technology which we had
to put in plac ~.
Q Am I correct in assuming this water solu
bility study again meant this piece of information
that you needed before you could do the biodegradation?
A Correct. Q Would you please explain what the methodology
you developed for this water solubility was?
A It involved sampling the reaction mass con
taining the microorganisms, the charged PCB and any
other materials that might be present, selectively
isolating residual charged PCB by appropriate extraction
technique and proceeding with the gas chromatography/
mass spectrometry separation, identification and
measurement. Q And the GC/MS would be the last step in that?
A Yes .
Q Of known quantity of solution, that would be
able to measure how much remains in that solution?
A Correct.
TU L. UrU
______________________________________________________________ 15^ ^outn I_a S^le Street
o , |i`tnoi9 60603
STLCOPCB4026724
Keller
direct
134
Q Did you do anything else to the technique or
the methodology that you can recall?
A No.
Q And similar to thebiodegradation study, did
you then utilize this methodology for each of the
Aroclor compounds?
A Correct.
Q Again, 1221 was the lowest,1260 was the
highest, is that correct?
A Correct.
Q How do you measure that finding you do come
up with on measuring water solubility? What is it,
a percentage or is it the weight? How do you measure -
A Reported as?
Q How is it reported,thank you.
A Part per billionlevels, reported as a
concentration, reported as a concentration which
dissolves in water at 25 degrees Centigrade or room
temperature.
Q Am I correct then at the medium that would
be 25 degrees Centigrade and the part per billion
measurement would be how much of a known quantity of
PCBs in that medium will dissolve at a part per billion
level?
~Tlnec< (_. i^_JrlDcm
fied Reportef 154 Coutli |_a lpc,He
Cluc^nc, |ilinoi? 60605
STLCOPCB4026725
Keller
direct
135
A Correct, how many part per billion of the
PCB under test will dissolve and go into the aqueous
phase .
Q Is there a time measurement involved in
this also?
A The times that are needed to properly corro
borate the emissible PCB with the water solution. My
best recollection is this involved a few days9 agi
tation, ending with allowing the phases to separate,
subsequently going in and sampling the water phase
and making the determination.
Q Would it be a different period of time for
each of the Aroclor compounds or would that be a
standard control?
A Appropriate intervals were selected with
the thought some might be more emissible than others,
but I cannot differentiate what the difference in time
was for you.
Q Could you recall what the part per billion
concentrations were for the Aroclors' range?
A Not specific for each one, but typical
level would be 200 part per billion of the Aroclor
1200 Series.
Q Do you recall if there was noticeable
""flneo 1__. l^Jrbon
(Certified RhortRnd Reporter-----------------------
134 Rcutn |_o Rnlle Rtreet
(Rkc^ro,
60603
STLCOPCB4026726
Keller
direct
136
difference in concentration between a lower chlorinated and a higher chlorinated, was that in the biodegrada
tion work? A Yes, on a relative basis, the lower chlori
nated components, PCBs would be somewhat more soluble
in this part per billion range than the higher chlori nated species.
Q The water solubility test results then were
used as components for your test of the biodegradation of the PCBs, is that correct, or not a component?
A Was used to guide a design of appropriate biodegradation tests.
Q Do you know of any other use which was made of this water solubility test results?
A Nothing comes to my mind at the moment. Q As the biodegradation studies, results and
your involvement with it, in degrading one of the Aroclors, it degrades at a certain percent. Would you still be able to determine after that Aroclor degrades what Aroclor it is? Does it change its
molecular weight in such a way that 1221 after degrading,
I think you said around 50 percent, subsequent measure ments, would that Aroclor still be able to be read as 1221 or would it now become 1242 or something like that?
----------- ---------------------------------------------------------------------------------------------------------------------
"T^ea 1_ Urban
Certified
ortkcinj [Reporter
134 |_a ^jalle Street a icooo . |l 11 no i S' 60603
STLCOPCB4026727
Keller
direct
137
Does it lose its initial identification,
I think is my question.
A Yes, because it is losing its characteris
tics of isomeric components.
Q Could that explain why Widmark and Jensen
and the person in Scotland kept finding the higher
chlorinated isomers because they really were, or a
lot of them were a lower chlorinated,at some point
biodegraded and now are being read as a higher component?
MR. FEATHERSTONE:
Would you read that back?
(Question read.)
MR. FEATHERSTONE:
Don't go any further.
A lower-chlorinated isomer does not
biodegrade into a higher chlorinated isomer. Is that
your question?
MR. HYNES:
Let me try it again, so I can under
stand this.
BY MR. HYNES:
Q A lower chlorinated PCB, lower chlorinated
Aroclor will, based on the results of your study, will
biodegrade to some extent?
A True.
Q Subsequent to that percent of biodegradation,
if someone took that remaining quantity of PCBs and
~]~hee> 1_. Urtjcrn
Certified SUtk, nd Reporter 134 Rood I_a Rcdle Rtreet rkr-q.c | Nino:? 6^603
-------------------
STLCOPCB4026728
Keller
direct
138
measured it, would they then be able to determine that
it is what its original composition was?
A No. Q Then would it be read as a higher chlorinated
hydrocarbon than it originally started out as?
MR. FEATHERSTONE:
Why would that --
MR. HYNES:
Stop. I know what I said wrong.
MR. FEATHERSTONE: BY MR. HYNES:
Maybe.
Q All I am trying to get to is Widmark and
Jensen findings, the concern that was expressed there
that they kept finding a higher chlorinated isomer,
five or greater isomers.
Did the results of your studies here,
at least to some extent, explain why there were the
quantities of PCBs identified with the higher isomers?
A The answer to that is yes. It is a possible
explanation.
MS. OLIVER:
Could I just ask a question?
MR. HYNES:
Yes.
MS. OLIVER:
Once a lower chlorinated isomer or
PCB is biodegraded to 50 percent or whatever, what is
it then identified as? MR. FEATHERSTONE:
Isomer doesn't biodegrade to
TU
t_J rlscin
Ce-tiU ortRnd Reporter (34 Recto |_a RrJIe Rtreet RkiCip^o, jlltnot? 60603
STLCOPCB4026729
Keller direct
139
50 percent, a product.
MS. OLIVER:
The product PCB, Aroclor.
MR. PEATHERSTONE: But Mr. Hynes made the same
mistake. You confuse isomer with the product.
MS. OLIVER:
What is it identified as on the
GC/mass spectrometer?
MR. FEATHERSTONE:
Why don't you take 1221 as an
example, if that is all right.
MS. OLIVER:
Sure.
THE WITNESS: I think I can clarify this issue
with two or three sentences' explanation.
MR. FEATHERSTONE:
All right.
THE WITNESS:
PCBs 'as an Aroclor product is a
mixture,as you know.
MR. FEATHERSTONE:
Mixture of isomers.
THE WITNESS: Mixture of isomers with varying
levels of chlorination in the mixture. Biodegradation
will, the bugs, the microorganisms chew up the lower
chlorinated species faster. If you are feeding them
a mixture, they then will reduce the level of the
lower chlorinated isomers or species so that the
residual PCB components remaining would tend to be
the higher chlorinated isomers.
MR. FEATHERSTONE:
Assuming there are higher
~Tkec> |_.
(P,ertif>eri 3^ ortkc^nj ["Reporter
iM `Souik L<?
reet
C ' t-' i C ra r* G . |ilmo! 6C603
STLCOPCB4026730
Keller
direct
140
chlorinated isomers in that original Aroclor.
THE WITNESS:
True, 1221 does not have higher -
MR. FEATHERS TONE:
What you have left is lower
chlorinated. They just have not biodegraded yet.
THE WITNESS:
Correct.
MS. OLIVER:
If you identify the lower chlorinated
isomers as being present after the product biodegrades
as much as it is going to?
THE WITNESS:
No.
MS. OLIVER:
What is it then identified as on the
GC/MS?
MR. FEATHERSTONE:
I think after 48 hours using
1221, you have 40 to 50 percent PCBs left is what you
have . THE WITNESS:
It will tend to be, it will be the
higher chlorinated isomer species in that 1221 mixture,
MR. FEATHERSTONE:
But they are still identified
as PCB isomers, not identified as Aroclor 1221.
MS. OLIVER:
That was my problem. Thank you. '
MR. FEATHERSTONE:
That was my problem with
your question. You kept confusing product with isomers
MR. HYNES: I think I have it as well as I'11
ever have it, MR. FEATHERSTONE
Let's go on to something else
________________________
"T"her' |_. t_JrOn
CeHiPieJ SP ort^cmd [Reporter'
134 1__a
reet
| H i no i g 60603
STLCOPCB4026731
Keller
direct
141
BY MR. HYNES:
Q You also stated that other types of work
that your group did was support for the medical group
and the business group with regard to doing analyses
of animal tissues for PCB levels, is that correct?
A Yes, correct.
Q When was that?
A Approximately 1970.
Q Was that a direct request from either the
Medical Department or the business group that you
do conduct these tests?
A Yes.
Q Were you involved in any discussions with
them concerning your capabilities to do it, your
desire to do it?
A Involved with the analytical parts of the
program, yes.
Q What was your involvement in that? What
were the discussions concerning?
A To assure that the right methodology would
be in place; to analyze tissues out of the studies for
residual components used for the study.
Q These were in conjunction with toxicity
testing being conducted, biodegradation tests, is that
TU L LWan
(Certified
Reporter
154 1_o Rtreet
Qic-o. H iiOOK 60603 .7
STLCOPCB4026732
\
Keller
direct
142
right?
A Correct.
Q Which toxicity tests were they?
A That was a province of the Medical Department
and we did not participate in the selection, design
those tests.
Q I didn't mean in the design and selection
of toxicity tests. I mean do you know the subject
matter of the test where your group analyzed the
tissues?
A Could you clarify subject matter?
Q Long term chronic toxicity tests on rabbits
or dogs or birds, the species that was studied?
A I was aware that there were animals, chickens,
rats, dogs, et cetera, under study. I personally did
not involve myself or become aware of what each of
these studies were because it was in their hands.
MR. FEATHERSTONE:
Mr. Hynes' question, Doctor,
was whether your analytical group analyzed animal
tissues or all the animals used in the tests or some
or none, I guess.
MR. HYNES:
No, I just wondered if he knew the
subject matter of specific tests where your group
analyzed the tissue.
~["hed |__.
C-tif'J
orthond Reporter1
!34 ^outk |_a Rcdle Street a tC&OO, |!!;n0;s 60603
STLCOPCB4026733
Keller
direct
143
BY THE WITNESS:
A Yes, then you said by subject matter, you
meant specific species which would be the rat, dog,
chicken.
BY MR. HYNES:
Q Let me put it this way:
When your group received the different
tissues from, I assume, the medical group, they were
the ones who gave you the tissues to be analyzed?
A Through them we received them directly in
some cases from Industrial Bio-Test Laboratories.
Q Did you set up a protocol as to the quantity
of tissues which you needed to do the analysis?
A We participated in assuring the methodology
used would have enough sensitivity for monitoring the
level of PCBs or whatever might be studied.
Q In other words, you set up the method, the
analytical method to follow and in setting that up,
you decided you needed X quantity of tissues to have
an accurate study done?
A Right.
Q Other than determining the levels of PCBs in
the various tissues being analyzed, did your group
have any other duties or responsibilities in that
"]~hea 1__. Urban
Certified
[Reporter
154 ^~>outn |_a ^>al!e ^t'Peet
a i cc?o c, | !! i non 60603
STLCOPCB4026734
Keller
direct
144
regard with those toxicity tests?
A No.
Q Had nothing to do with the interpretations
at all other than just the levels of PCBs found in
the tissue?
A Our responsibility was to make the determina
tions, report the levels found to te other groups,
Q Who did you report your findings back to?
A This was to the manager of the research
unit for Functional Fluids and to the Medical Depart
ment.
ed You did not report them back to IBT and
they in turn reported back to Functional Fluids?
A No, our clients in this case were Functional
Fluids and the Medical Department.
Q Do you recall doing any other analysis of
PCBs other than the three we have just gone through
that were out of routine-type work your division would
be doing? MR. FEATHERSTONE:
That has already been answered,
Mr. Hynes.
BY MR. HYNES: Q For your clients? Those are the only non-
routine type tests?
"Theo 1_. Urban
Certified SCrtk o nd [Reporter
13^1 SoutK |_o
Street
cu,
now 60603
STLCOPCB4026735
Keller
direct
145
A That's right. Q Do you recall if your group or yourself ever did any analyses of Monsanto products containing PCBs where you were looking for dibenzyl furans?
A Yes.
Q Did you do any other analytical work for similar types of impurities in PCB products, and I
will give you an example --
MR. FEATHERSTONE:
Jim, why don't you relate the
question specifically to impurities rather than similar
types.
BY MR. HYNES :
Q Did you do any analysis of the impurities
in the PCB-bearing products at Monsanto?
A Yes .
Q Were there specific impurities that you were
looking for?
A Yes .
Q Which were they?
A Dibenzyl furans.
Q Any others?
A Yes .
Q Which?
A Dioxins.
TU L. UrU
___________________________________________________ _____
154 Routn \_a R^lle Rtreet
CRiccj^o, Illinois 60605
STLCOPCB4026736
Keller
direct
146
Q Any others? A No. Q Was that dioxins,plural? A Plural, Q Are there different types of dioxins?
.
MR. FEATHERSTONE:
Is there a dioxin in this
case, Mr. Hynes?
MR. HYNES:
No, I want to find out what testing -
MR. FEATHERSTONE: You may want to find out a
lot of things, but how are dioxins and dibenzyl furans
relative to the lawsuit involving Waukegan Harbor?
MR. HYNES:
Because the information from Europe
from the University of Utrecht found they had found
impurities such as dibenzyl furans in the PCB products
in Europe. I want to find out if such impurities were
found in the Monsanto products.
MR. FEATHERSTONE:
How is that relevant?
MR. HYNES:
Because they are very highly toxic
poisons. If they are in the Monsanto products, that
is a clear problem. MR. FEATHERSTONE:
Have you checked for dibenzyl
furans in Waukegan Harbor?
MR. HYNES:
That doesn't matter. I am asking
what Monsanto did.
"T^ec1 |_. t_Jrbon
(Certified Rkorthond Reporter
134 Soutk [_a Rcilie Rtreet CUronn I lllnolc 60603
STLCOPCB4026737
Keller
direct
147
MR. FEATHERSTONE:
We certainly did not search
for dibenzyl furans.
MR. HYNES:
But your product is the issue in the
case here.
MR. FEATHERSTONE:
No, PCBs.
MR. HYNES:
Yes, PCBs from your product.
MR. FEATHERSTONE:
PCBs are not dibenzyl furans.
MR. HYNES:
But if impurities are found in the
process of manufacturing PCBs in a company in Europe,
which clearly if they are found here makes a PCB-
bearing product more dangerous, much more toxic. If
there are no impurities like this in the product,
that's fine, but if that is part of the impurity in
a product that is causing a problem, we certainly can
get into that to see whether or not -
MR. FEATHERSTONE:
The fact is your defense
witness searched for dibenzyl furans in Waukegan Harbor
and failed to find any.
MR. HYNES:
And I am sure I can ask Dr. Keller
who said he did do research to see if there were these
impurities in the product and I expect he would answer
what he looked for, what he found.
MR. FEATHERSTONE:
I mean you don't have the
specific research relative to what you claim to be
"]~keci 1_. UrkcJn
ortRnd Reporter
13* Rcutk
S-HeStreet
Jilinoi? 60603
t-n - 7ft?-333?
STLCOPCB4026738
Keller
direct
148
relevant in the lawsuit; in other words, whether there
are dibenzyl furans.
Your expert looked, your trial witness
looked.
MR. HYNES:
We did not manu f actu re the product.
Monsanto did. MR. FEATHERSTONE:
What dif f eren ce does it make 7
MR. HYNES :
What do you mean wha t difference
does it :make? If you have an impurity in a product
and that impurity is a highly toxic po ison or highly
toxic substance, isn't Monsanto respon sible for what
is in their product?
MR. FEATHERSTONE:
Your lawsuit involves PCBs
at the bottom of Waukegan Harbor. It doesn't matter
to take the point abstractly, what is over in
California or in France. What is in Waukegan?
MR. HYNES:
The manufacturing process of PCBs
for the product in Waukegan Harbor, I would have to
assume is the same manufacturing process for PCBs by
Monsanto for any other company that purchases their
products and I don't care if they are found here, there.
I want to find out if Monsanto found these impurities
in their product and the product in question.
MR. FEATHERSTONE:
First of all, your expert
~Pkec |_.
fied SLrtSnd Reporter
134 SeL La SaNe Street (3'n ic^cjo, |limoi9 60603
STLCOPCB4026739
Keller
direct
149
didn't look. MR. HYNES:
What does my expert have to do with
it, if it has anything to do with it?
MR. FEATHERSTONE:
To take your point, the
presence or absence of the impurity, assuming it is
relevant to the lawsuit, is relevant only insofar as
whether it is in Waukegan Harbor. Your guy looked for
it and did not find it and told you that in a written
report.
Secondly, why don't you ask some of
your experts which impurities or their manufacture or intended manufacture are predictable. I mean, they will tell you that presumably because one lot has it doesn't mean the second lot has it or has it
in the same quantity. I have made my objection on relevancy.
We will let him answer the question, but we will not
go much further than that. BY MR. HYNES:
Q I think my question was. Doctor, are there
different types of dioxins?
A Yes.
Q Which are the types that you --
MR. FEATHERSTONE:
You can ask him whether he
Theci (_.* 7
Ceri;*`
ortl~ic?nd ["-Reporter
134 Soutk LS*HeSt
a \C<?oo, ] 11 inoi9 60603 7 n "7QO ZZT'-I
STLCOPCB4026740
found out. BY MR. HYNES:
Q Did you say you checked for impurities, for
dibenzyl impurities and you checked for dioxins and that was all you checked for, is that correct?
A In the -- would you repeat the question again, please?
Q All right. I believe you said that your group
checked for impurities in PCB products of Monsanto,
is that correct? A Correct. Q And two of the impurities that you checked
for were dibenzyl furans and dioxins, is that correct?
A Correct. Q Do you recall looking for any other impurities
other than these two? A No. Q Did you find any dibenzyl furans or dioxins
in any of your products?
MR. FEATHERSTONE:
You can answer.
BY THE WITNESS:
A No . MR. HYNES
If you knew what the answer was, you
------------------------------------------------
"Thee I_. l_Jrb^n
CeH.fied ortlicinci [Reporter 134 ^outh 1_a ^dlle Street o \caao, Illinois 60603 31? - 787-333?
STLCOPCB4026741
Keller
direct
151
could have saved ten minutes.
MR. FEATHERSTONE:
No, we could save a couple
of hours if you would stick to the issues in the law
suit, Mr. Hynes.
BY MR. HYNES:
Q After your group completed the water solu
bility tests or series of water solubility tests, am
I correct that there was just one series of tests and
that was used in the biodegradation studies?
A Right.
Q The series of tests which you did on the
animal tissues, there were several analyses, several
tests. When did they conclude the last analysis
your group did, do you recall?
A Those tests extended over a period of time
because some were long term tests, as I recollect;
for example, two-year studies, so it was a period of
several years.
Q Your involvement of the two to three-year
period during some components of the test throughout -
A Yes.
Q Do you recall when the last test was conducted
roughly?
A No , I don't.
"T^ea 1_. Urb/an
(RertiRJ Rkor-lRnd Reporter
13)4 Scutk 1_a
lie Street
jlltnois 60605
-------------------
STLCOPCB4026742
Keller
direct
152
Q
Do you recall or were you involved in any
,
other non-routine test involving PCBs or PCB products
at Monsanto subsequent to 1973?
MR. FEATHERSTONE:
How is that relevant?
MR. HYNES:
Well, PCBs stopped being produced in,
I am guessing, 1975; between '73 and '75 when PCBs
stopped.
MR. FEATHERSTONE:
We stopped selling PCBs to
Johnson Motors sometime late '70 or early '71. Why
are we up to '75?
MR. HYNES:
To see if he did any more research
involving this to see what the problems were, the
knowledge of Monsanto as to any problems in the
environment as to PCBs.
MR. FEATHERSTONE:
How is Monsanto's knowledge
of that germane, a duty to warn, is that your count?
MR. HYNES:
Right.
MR. FEATHERSTONE:
It is?
MR. HYNES:
Yes.
BY MR. HYNES :
Q Did you do any further questioning in the
area other than these three categories of studies that
you recall?
MR. FEATHERSTONE:
You can answer that yes or no.
L U rban
Certified Sf ortfond Reporter
154 Route |_a RoiHe Rtreet
a..
60603
STLCOPCB4026743
Keller
direct
153
BY THE WITNESS:
.
A The answer is no.
BY MR. HYNES:
Q Other than in a routine type of test that
your group would get, your involvement with PCBs
essentially stopped when these three tests were
concluded, is that correct?
MR. FEATHERSTONE:
Up to "75 which is your --
BY MR. HYNES:
Q Up to 1975.
A Correct.
Q
I think you saidearlier
that your group
did an analysis, I am not sure how many. Do you re
call doing some analyses of samples sent to you from
the business group from Johnson Motors in Waukegan?
A That's correct.
Q Do you recall how many samples your group
analyzed from Johnson Motors?
A On the order of 5 to 10 samples.
Q Do you recall that they came in at distinctly
different times or all of them came in at once and you
did the five or so samples at one time?
A There were severalintervals.
Q Where did you get these samples from, do you
Tb ec |_. Urban Certified CCrtkond Reporter
134 Soutk \_a SHe St rest Illinois 60603
STLCOPCB4026744
Keller
direct
154
recall? A
. Through our business group and the marketing
function.
Q That again would be through the Functional
Fluids group?
A Functional Fluids. When I say business group,
I am talking about Functional Fluids.
MR. FEATHERSTONE:
You are talking about PCBs?
THE WITNESS:
When you are talking about PCBs,
yes .
BY MR. HYNES:
Q You said just now marketing. Would that be
the marketing group within the Functional Fluids?
A Correct.
Q Do you recall who the person was who delivered
that sample or samples to you? A This was Pogue, P-o-g-u-e. Q Do you recall what was sampled? Was it water
that was sampled to determine PCB content or was it
sediment?
Was it oil out of a pipe, do you recall
what it was? A It was my recollection that these are effluent
samples from Johnson Motors.
Tk ec? 1__. 1>U
Certified ortkipnc) [Reporter
f34 Sout^ |_a
Street
C'niC.^o, j i 11 no i ? 60603
STLCOPCB4026745
Keller
direct
155
0 Do you recall what the findings were in terms
of PCB content?
A PCBs found ranged roughly from 10 to 100
to 200 part per million.
Q Did your group or did you yourself have any
involvement with communicating these results directly
to Johnson or go back through the business group
which requested you do the analyses?
A Yes .
MR. FEATHERSTONE:
It was a compound question,
that is the problem.
Yes as to the latter part of that
ques tion?
THE WITNESS:
Would you rephrase the question.
BY MR. HYNES:
Q You sent the results back to the business
group that requested the analysis be done, is that
correct?
A Correct.
Q Do you know what they did with the analysis
results ?
A No, I don't.
Q Would that request be considered a routine
type of task for your group?
~\~be& L. lU*"
____________________________________________________________ _
Certified
134 Routk |_a Rdile Rtreet
Rkic.<yc|0, |i!mois 6C603
STLCOPCB4026746
Keller
direct
156
A Yes.
.
Q Prior to your getting the equipment, the
gas chromatograph/mass spectrometer, do you recall
whether your group was ever requested to test a cus
tomer's effluent or a product for presence of PCBs?
A Not that I recall.
MR. FEATHERSTONE:
When you say was the request
from the business group with respect to Johnson Motors'
sample a routine request, do you mean routine request
at about that point in time?
BY THE WITNESS:
A I assume you were talking about that period
of time we have been concentrating on, 1970.
BY MR. HYNES:
Q Right.
A Yes.
Q Were you ever involved within Monsanto with
any meetings or discussions concerning labeling of
PCB products?
A No.
Q Were you ever involved in or did you ever
discuss the concept of sending out warning letters to
customers who purchase PCB products?
A No .
T heei j_. Url^n RertReJ Rliorthcand Reporter
134 Routk 1_o Ralle Rtreet Illinois 60603
STLCOPCB4026747
Keller
direct
157
Q Were you ever involved in any meetings
within Monsanto concerning a management plan in deal
ing with the PCB problem?
A Yes, from the analytical standpoint.
Q When was your first meeting as you recall
with regard to management of PCBs within Monsanto?
A Approximately the same period of time.
MR. FEATHERSTONE:
1970?
THE WITNESS:
1970.
BY MR. HYNES:
Q What was your involvement in it?
A To assure proper analytical coverage needed
for projects planned out of the Functional Fluids
group and Medical Department.
Q In other words, in terms of decision-making
suggestions, you were not involved unless it dealt
with analytical techniques concerning presence,
absence of PCBs and levels?
A Correct.
Q Were you ever involved with the Sales Depart
ment within Functional Fluids, the marketing group
within Functional Fluids assisting them in anything
dealing with PCBs other than the routine testing that
you did?
Tke. (_. Url^n
Certified SCrtCnd Reporter-----------------------!M ^pjouth |_a ^cille Street
Celtic|itinci? 60603
STLCOPCB4026748
Keller
direct
158
A No .
Q Were you ever involved in any work dealing
with reclamation ofPCB fluids?
A No .
Q Do you knowas of today if the infrared
spectrometer technique, the technique that is avail
able today, is that capable of detecting PCBs?
MR. FEATHERSTONE:
Objection, relevancy.
If you can answer that, go ahead.
THE WITNESS:
Pardon?
MR. FEATHERSTONE:
If you can answer it, go ahead
and answer it.
Do you have the question in mind?
THE WITNESS :
Could you restate the question?
MR. HYNES:
Could you repeat it?
(Question read.)
BY THE WITNESS:
A Possibly detecting but not absolute identi
fication.
BY MR. HYNES :
Q What do you mean by absolute identification?
A As to the exact chemical structure of the
PCB .
Q The amount of chlorination, is that what you
----------------------------------------------------------------------------------------- .---------------------------------
I_- l_JrOn Certified 5^ oriiRnci Reporter
134 Rout^ 1_a Rctlle Street a \cooo, jiiinoi? 60603
-
STLCOPCB4026749
Keller
direct
159
mean by that?
MR. FEATHERSTONE:
Position?
BY THE WITNESS:
A The position of the atoms in the chemical
structure, the numbers, the types, their relative
positions.
BY MR. HYNES:
Q Do you have an opinion as to when that
technique was available or first available?
MR. FEATHERSTONE:
You mean when today's tech
nique was first available?
MR. HYNES:
Yes.
MR. FEATHERSTONE:
I object to the form of the
question. Opinion as to when it was? Does he know
when it was?
MR. HYNES:
Fine.
MR. FEATHERSTONE:
There is a difference.
BY MR. HYNES:
Q Do you know when it was first available?
A Today's technique is not that different from
the technique existing years ago in the 1950s.
Q The ability to detect PCBs using today's
technique which is, you say, similar to the one back
in the 850s, when was there first a capacity to detect
Theca |_. TJrhcan
Tea'ti!'ied hTorthcand ("Reporter
134 Soutk |_a S^cille Street 11! i not 7 60603
STLCOPCB4026750
Keller
direct
160
PCBs using infrared spectroscopy?
MR. FEATHERSTONE:
In what kind of sample,
environmental sample, in a known sample?
We have been through this this morning
about the difference.
MR. HYNES:
In an unknown sample.
BY THE WITNESS:
A The infrared doesn't have the capability of
detecting, that is, identifying PCBs as chemical
structures.
BY MR. HYNES:
Q Even today?
A Today.
Q If someone were to look for PCBs, would they
i le to detect it?
MS . OLIVER:
Today?
MR. HYNES:
Using the technology today.
MR. FEATHERSTONE:
In a known or unknown sample?
MR . HYNES:
No, I am saying if they were looking
for it, if they don't know it was in the sample.
MR. FEATHERSTONE:
Unknown sample.
BY MR. HYNES: Q Is that what you mean by unknown sample,
you are looking for it, you don't know what is in the
-----------------------------------------------------------------------------------------------
TU |_. UrLan
(Certified
[Reporter
llA <W{, [_a
Street
o ICP^O, J!Imoi? 60603
---------
STLCOPCB4026751
Keller
direct
161
sample. Is that what you meant by it?
A Yes.
Q All right. A May I add to this forclarification?
The infrared then, back in the '50s,
and today has capability for showing certain structures
in chemical compounds.
It does not have the capability of
putting these structures together and showing you
what final chemical structure exists and if you move
into complex mixtures, then it has no chance to
demonstrate this. MR. FEATHERSTONE:
Complex mixtures such as
PCBs? THE WITNESS:
PCBs.
BY MR. HYNES:
Q Do you know who Lou Stark is?
A Yes , I do. Q Did Mr. Stark work for you at any point?
A No. Q What was his position at Monsanto, if you
recall? A Group Leader in the Functional Fluids
group.
Tliea |_. Urlsan
CeA ifled ortRnJ Reporter
134 R o u t ^ \_a
Rtreet
Q; C o n o, I llino.s 60603
STLCOPCB4026752
Keller
direct
162
Q That was not in your division? A That was not in my area.
Q What was his function, do you recall?
MR. FEATHERSTONE:
You have taken his deposition,
Mr. Hynes .
MR. HYNES:
You're right.
BY MR. IIYNES :
Q Scott Tucker, did he work for you? A Yes .
Q What was his position with you?
MR. FEATHERSTONE:
Why don't you pick a year.
BY MR. HYNES:
Q 1970, did he work for you? A Yes .
Q What was his position? A He was group leader of the analytical group.
Q Was he involved in either the biodegradation study ---
A Yes . Q Was he involved in working on the water solubility study?
A Yes .
Q Was he involved in working on the tissue
studies?
~Tkec I__-
Certified Ckorthand Reporter --------------------------
134 Soutf |_a Rolle Ctreet Cficooc, Illinois 60603
STLCOPCB4026753
Keller
direct cross (Oliver)
163
A Yes .
Q Was it his group that he was a group leader,
was it his group that was doing the work on these
three studies?
A His group did a major part of the total
effort, yes.
MR. HYNES:
I don't have any more questions at
this time.
MS. OLIVER:
I just want to go through some of
this material we went over.
MR. FEATHERS TONE:
Let's take a short break.
(Brief recess had.)
CROSS EXAMINATION
BY MS. OLIVER:
Q Dr. Keller, my name is Roseann Oliver. I
represent Outboard Marine Company in this litigation.
I have some questions and we are going
to be jumping back around on some of the information
you testified about earlier.
You earlier gave some examples of some
articles that you wrote during your professional career
with Monsanto. Have you prepared a list of your pub
lications?
A I could develop a list.
TU L. 16L n
(^eriifteJ
["-Reporter
134 South \__a 5^He Street | 1! i n o i ? 60603
STLCOPCB4026754
Keller
cross (Oliver)
164
MR. FEATHERSTONE:
The question is have you pre
pared one.
BY THE WITNESS:
A I have not prepared a list.
BY MS. OLIVER:
Q You talked earlier about starting at Monsanto
as a research chemist in the Organic Chemicals Division.
Was there a group within the division that you worked
in?
A Yes.
Q What was the name of that group?
A It was Physical Chemistry group.
Q Were you in the Physical Chemistry group
during your career?
A I started in the Physical Chemistry group
as an analytical chemist first in the Organic Chemicals
Division.
Q Actually during your period of time that
you worked for the Smith, Klein Laboratory, the
laboratory on the development of methods for analyzing
pharmaceutical products, did you do any work on side
effects of drugs or toxicological effects of drugs?
A No.
Q When you became a project leader in 1956 or
"T^eo 1_. (^JrLwri Certified ortkcinJ [Reporter
134 ^outk |_a petite Street CIllinois 60603
STLCOPCB4026755
Keller
cross (Oliver)
165
there abouts with Monsanto, was that in the Physical
Chemi stry section?
A Yes.
Q As group leader, you were in the Physical
Chemi stry Section?
A Yes. At that point we established the
Analy tical group. The Physical Chemistry group con-
tinue d and it became a section at that point.
MR. FEATHERSTONE:
Analytical group became a
section or the Physical --
THE WITNESS:
The Analytical group and the
Physical Chemistry group together made up a section.
BY MS. OLIVER:
Q You were in charge of the Analytical group?
A Correct.
Q Were those groups within the Research and
Development Section of the Organic Chemicals Division?
A It was a support unit within the Organic
Division, Research and Development Department.
Q Before the seven years that you were head
of the Analytical group, who did you report to?
A I reported to an assistant director of
research.
Q And the assistant director of research was
TU |__. l^Jrbcin
---------------------------------------------------------------------------------(Certified ^>kort!^nd [d^eporter 134 j__a ^dcille Street
STLCOPCB4026756
Keller
cross (Oliver)
166
for the research group and in the Organic Chemicals
Division?
A The assistant director was responsible for
the section, made up of two groups: Physical Chemistry
and Analytical Chemistry.
Q Who was that assistant
director?
A Ralph Muench.
Q In about 1965 or so when you became the
senior research group leader, that was still in the
Applied Chemistry group?
A And Analytical Chemistry group.
MR. FEATHERSTONE:
What is the amount of time,
what is -
MS. OLIVER:
Let me start over.
BY MS. OLIVER:
Q In about 1965 when you became senior research
group leader, were you still in the Analytical group?
A Correct.
Q Did you report to --
A Correction to that. I was responsible for
the Analytical group and I was both in it and respon
sible for it.
Q Did you still report to Dr.Muench as a
direct supervisor?
-----------------------------------------------------------------------------------------------------
'
Certified S^i orthcmd Reporter 134 ^outh j_a Rcille Street
aucarjo, | 11 mo i? 60605
----------
'
.
STLCOPCB4026757
Keller
cross (Oliver)
167
A There was a period there where I reported to
another assistant director of research, resulting
from reorganization of the Research and Development Department of the Organic Chemicals Division.
I am not sure just what year that
occurred, what period that occurred, but it was about
that period of time.
Q Who was that person?
A That would have been Harold Hubbard.
Q Would I be correct for the period 1968 to
1970 you and Dr. Richard were on parallel positions?
A Essentially, yes. Q And your group did work for Dr. Richard's
group as you were asked to do?
A He was our client, yes.
Q And the Medical group was also a client?
A Yes . Q In the period before 1967 when you first
learned about the reports of PCBs in the environment,
could you tell me generally what types of projects
were referred for work by the Medical Department?
A Prior to 1967?
Q Yes .
A Projects related to analytical studies,
"The I_
----------------------------------------------------------------------------------------------------Ce"iified Sh ort^cincl [Reporter __________
134
|_a 11 e Street
a \COOo, | 1! inoi? 60603
STLCOPCB4026758
Keller
cross (Oliver)
168
determinations of products of interest to our division.
Organic Chemicals Division, which for some reason they
needed out of their projects; whether it was toxicology
or whatever, and I'm not sure. I cannot give you
specifics beyond that.
Q Could you tell me generally what types of
analytical work your group did for the Medical Depart
ment before 1967?
MR. FEATHERSTONE:
Can you give us an example?
MS. OLIVER:
That is what I am asking. Dr.
Keller said he did support-type projects for the
Medical Department as a client and I am just asking
what types of projects were done.
MR. FEATHERSTONE:
And he did analytical support-
type projects.
MS. OLIVER:
Yes.
MR. FEATHERSTONE:
Can you remember anything
specific?
THE WITNESS:
Not specific enough that I would
even want to use it as an example.
BY MS. OLIVER:
Q Would it be fair to say that most of the
projects that came to you were from the business group
rather than the Medical Department?
____________ -- -- :
djer-tlf!eJ Sk ortkond Reporter
~]Seo [_ LJ^tcin
.-----------------------------------------------------------------------------------------
134 Routk [_a SRIle Street
a iccjgo, Illinois- 60603
STLCOPCB4026759
Keller cross (Oliver)
169
A Correct Q When we talk about projects being referred to your group by the business group, we are talking about the Research and Development Section of the business group? A Correct Q You mentioned that in 1971, you became manager of Applied Sciences group and you had res ponsibility for five different groups under you. The Organic Analytical group that you had responsibility for was the group that previously you had belonged to, is that correct? A Yes, with comment that there was an internal reorganization within our own area of what we are referring to as Applied Sciences, so that we re distributed certain functions and prior to the five groups that you have referred to here known as Applied Sciences, we were divided into a spectroscopy group, analytical chemistry and environmental testing group, a physical chemistry group, instrument development group, applied math and computer sciences group. Q So prior to 1971, the groups within Applied Sciences were the spectroscopy group, the analytical chemistry group --
STLCOPCB4026760
Keller
cross (Oliver)
170
A Analytical chemistry and environmental testing.
Q The physical chemistry group?
A Right.
Q The instrument development group and applied
math and computer sciences group?
A Correct.
Q Had those groups been in existence within
Monsanto in St. Louis from the time you began working
with Monsanto?
A The functions of those groups were inplace.
It was a matter of regrouping functions into the final
five groups we called Applied Sciences.
Q When were those groups -
MR. FEATHERSTONE:
Identifiable as such?
MS. OLIVER:
Yes, prior to 1971.
BY THE WITNESS:
A Could you clarify those groups?
BY MR. OLIVER:
Q The spectroscopy group, et cetera, the groups
that you mentioned.
A Those groups existed for approximately two
to three years prior to the final formation of five
groups known as Applied Sciences.
Q
_____Citified
Before the two to three years before 1971,
~Tkea 1_. Urtxan
cmcJ [Reporter 134 Souik S^lie Streefc
jfltnoi? 60605 - 7R7-555?
---------
STLCOPCB4026761
Keller
cross (Oliver)
171
were there people within the analytical section who
had responsibility for spectroscopy work?
A Yes .
Q Was there a person or persons within the
analytical group who had that responsibility during
the time you were with Monsanto from 1954?
A I hadresponsibility for thatanalytical
group from the '50s to the point I became a section
manager, and at that point I picked up responsibilities
for the other groups, the physical chemistry, et cetera.
Q But my question is was there somebody within
Monsanto who was responsible with respect to spectros
copy work?
A Yes .
Q To your knowledge, was theresomebody
with
that responsibility from 1954 on?
A Well, the spectroscopy group didn't exist
from 19 5 4 on.
Q When did it come into existence?
A Approximately two to three years prior to
my becoming a section manager.
Q When did the instrument development group
come into existence?
A The function covered by that group and the
j__ . Urban
----------------------------------------------------------------------------------------------------------------- Certified ortkcpnd Reporter ------------------. !34 Routn |_o R^lle Rtreet
(Rktc^^o, jiltnoi'T 60603
ZJO . 7P9.7U9
STLCOPCB4026762
Keller
cross (Oliver)
172
group itself was established approximately 1957 or
1958.
Q And the function of the instrument develop
ment group was to develop instruments for use on
Monsanto products?
A Correct, processes, custom instruments di
rected toward monitoring processes of the division,
the Organic Chemicals Division, and custom instruments
needed for research and development activities.
Q In about 1965, could you tell me who the
group leader or head of that group was?
A The instrument development group?
Q Yes.
A Louis Fowler, F-o-w-l-e-r.
Q And the instrument development group is
still in existence within Monsanto, is that correct.
Dr. Keller?
A That is correct.
Q Who is -
A I will have to clarify. The Organic Chemicals
Division had an instrument development group. The
Inorganic Chemicals Division had a counterpart group.
Upon formation of an operating company, these two
groups were put together and made into one and continued
-------------------------------------------------------------------------------------
TU 1_. Urtwn
Certified orthcnd [^eporte'r 134 ^ooutk 1_a ^ciiie Street a iccur'o, Illinois' 60603
---
STLCOPCB4026763
Keller cross (Oliver)
173
as part of Applied Sciences.
Q Who presently is head of the instrument
development group?
A James Combs, C-o-m-b-s,
Q How long has he been head of the group?
A Approximately 20 years,with the first part
of that being group leader of that group in the Inorganic
Chemicals group.
Q Inorganic?
A Inorganic Chemicals Division. He shortly
after combined the two groups with the Functional
Industry Company, moved over as group leader of that
group.
Q Is Mr. Fowler still with the company?
A He is deceased.
MR. FEATHERSTONE:
Seance time.
MS. OLIVER:
That's right.
MR. FEATHERSTONE:
Federal rules provide for
liberal discovery.
BY MS. OLIVER:
Q We have talked a lot today about the gas
chromatograph/mass spectrometer and I think you testi
fied that the gas chromatograph was available to be
used since the early '60s.
------------------------------------------------------------------------ -------------------------------------------------------------------
T^>e^ 1_. Urtwn
Certified Rfortf ond Reporter
134 Routf (_a ffLIIe Rtreet CkiCiJr-io. |llinoir 6C603
STLCOPCB4026764
Keller cross (Oliver)
174
A Yes .
Q Your group had a gas chromatograph in the
early '60s?
A Our group was instrumental in the United
States of being the first in operation. Dr Munch,
the name I mentioned earlier, was the first to build
a gas chromatograph in this country. Because of that,
we have maintained a high expertise.
MR. FEATHERSTONE:
The question was do we have
one in the early '60s.
BY THE WITNESS:
A Yes .
BY MS. OLIVER:
Q Was a mass spectrometer available in the
early '60s?
A To the Applied Sciences group?
Q Sure.
A NO.
Q Do you know what use a mass spectrometer
could be put to without the gas chromatograph being
coupled with it?
A Yes.
Q What was its use?
A For study of organic structures of chemical
------------------------------------------------------------------------------------------.--------_----- ------------- ----- --
T^eci 1_. t_Jrl>dn
(Certified Rhorthand Reporter
134 Routh [_o Ralle Rtreet
RniCiPC'O, jliinotT 60603
STLCOPCB4026765
Keller
cross (Oliver)
175
compounds and certain simple mixtures; a technique used
more extensively by the oil and petroleum products
industry.
Q To your knowledge, when was the mass spectro
meter available in the chemistry field?
MR. FEATHERSTONE:
Which one, you mean in any
form -- I mean it seems to get more sophisticated --
BY MS. OLIVER:
Q In any form. A 1950s, possibly the 1940s.
Q The analytical group at Monsanto that you worked in did not have a mass spectrometer is that
correct?
A Did not have one.
Q For purposes of the work that was being done
in the analytical group, it was not considered to be
a helpful tool?
MR. FEATHERSTONE:
Monsanto was not in the
petroleum business.
MS. OLIVER:
I am asking the question.
MR. FEATHERSTONE:
He said it was used for the
oil and petroleum products.
MR. HYNES:
He said mainly used for that.
BY MS. OLIVER:
eo L U^Ln
Certified SCrtkc nd Reporter
134 Routk |_a Rrdle Rtreet CR\zoao, Illinois' (60603
STLCOPCB4026766
Keller
cross (Oliver)
176
Q It was no t considered to be a helpful tool? A It was no t a common tool to analytical laboratories at that period of time e Q Did it provide similar information that you would obtain from the gas chromatograph? A No. Q What are the differences in the information between a gas chromatograph and the mass spectrometer? A The gas chromatograph separates chemical compounds into different fractions without identifi cation .
A mass spectrometer will identify a chemical compound or in some cases simple mixtures as to chemical structure.
Q In the '60s or the '50s, was a mass spectro meter similar to an infrared spectrometer?
A No. Q What is the difference between those two? A Entirely different principles. The mass spectrometer takes a chemical compound, for instance, electron beams are impacted on this compound breaking it into parts. These parts are separated different ways, but for example, with a magnetic field, and it is these parts that are characteristic of the chemical
~Tkeo 1_ Urisdn
Citified Sk ortkond Reporter
134 Routk |_a Rcdle Street
CL I Iknnic 30303
STLCOPCB4026767
Keller
cross (Oliver)
177
structure.
.
Infrared, on the other hand, is dependent
on putting a sample, the same compound in solution.
The compound is not broken down or destroyed, but
rather is left in solution and an infrared light of
varying wave lengths will be put into the solution
and the chemical structure by what they call vibration
resonance of certain unique structures will absorb
different wave lengths of that light.
The light that gets through is picked
up on a record or chart and is a good indicator of the
core of structures present, but it does not have the
ability to put all the structures together and say
here was the chemical compound in question, especially
with mixtures and especially with unknown materials.
Q If I understand the principles correctly,
it becomes more difficult to identify what you may
have in a sample using the infrared spectrometer if
the sample is a mixture of different compounds or
chemicals, is that correct?
A Definitely.
Q For example, in Pydraul, which Pydraul A-200
to my understanding is a mixture of two different
Aroclors, 1242 and 1248, would that complicate the
Thee I_ Urban
Certified
ortRnd Reporter
154 RoutSj' [__a Rdlle Street Illinois' 60603
STLCOPCB4026768
Keller
cross (Oliver)
178
identification of the detection of PCBs using an
infrared spectrometer?
MR. FEATHERSTONE:
Complicate over what?
MS. OLIVER:
Complicate the ability or capacity
to detect.
MR. FEATHERSTONE:
You mean the fact that it is
a product of two Aroclors?
MS. OLIVER:
Yes, a mixture of two Aroclors.
BY THE WITNESS:
A The more components present, the more diffi
cult it is to detect. In the example you gave, the
infrared would, and I won't cover everything, but as
an example, would be able to perhaps pick up that
there is an aromatic 6-carbon ring. It might show
a carbon chlorine chain, perhaps not much more than
that, and from that point on, I can't tell you.
There would be considerable question
about whether it was PCB, some other types of compounds
containing those two structures I gave as examples.
MR. FEATHERSTONE:
You don't know how it is put
together?
THE WITNESS:
That's right.
BY MS. OLIVER:
Q Would you be able to tell at least that much
--------------------------------------------------------------------------------------Certified 3^ crtRnJ Reporter
134 Routn |_a
Street
Illinois 60603
STLCOPCB4026769
Keller
cross (Oliver)
179
using a gas chromatograph?
A No.
Q So what you are saying is you would be able
to tell less about the substance you are putting in
or sampling?
A Correct.
Q Using the gas chromatograph?
A Yes.
Q Monsanto had a European office or offices in
the '60s and the early '70s, is that correct?
A Yes.
Q Was there an analytical group in Europe that
was comparable to your group in St. Louis?
A Yes.
Q In the '60s, did you work with that group
in Europe on projects?
A We worked with projects occasionally.
Q I assume you would exchange information?
A When needed, yes.
Q Where was that.group located?
A That was at our European plant in North
Wales
Q Do you know how long that group was in
existence in Europe?
"T^eci I_
Certified Sf ortRnd Reporter*
134 Routli 1__o Rcdle Street
a i cone, illinois 60603
STLCOPCB4026770
Keller
cross (Oliver)
180
A At least from the '50s. Q You mentioned a group called the Monsanto
Research Corporation which is a corporate research support arm. When was that formed?
A I don't know the answer to that; years ago.
Q During the time that you were in the Organic Chemicals Division, from 1965 to 1972 or '73, whenever the reorganization took place, who was the manager
or head of that division?
MR. FEATIIERSTONE:
Of what division? Of Organic?
MS. OLIVER:
Organic Chemicals.
MR. FEATHERSTONE:
Over what period of time?
BY MS. OLIVER:
Q '65 to '73.
A The director of research and development.
MR FEATHERSTONE:
You want the head of the
Organic Development or the Research Development?
MS OLIVER:
The Organic Development of the
Chemicals Division.
MR. FEATHERSTONE:
The whole division?
BY THE WITNESS:
A The name that I am quite sure was in place
at that point as head of the division was Howard
Minkler.
Tk ea L UrUn
Certified
134
C" 1
ortkcanJ f~^eporte r
1_a Street
I I 1 - _ . . A r^. A r\ n.
STLCOPCB4026771
Keller
cross (Oliver)
181
BY MS. OLIVER:
Q Is he still with Monsanto?
A No, he is not.
Q Do you know when he left Monsanto?
A Approximately 1965.
MR. FEATHERSTONE:
We have -- I am going to jump
1 n.
, The question was who was head of
Organic Chemicals Division from "65 to 972. You
named Howard Minkler and then you said he left in
'65, but how can he be? Have you got his departure
date wrong or the wrong fellow?
THE WITNESS:
I am estimating the departure
date and I am not clear in my own mind.
The period that Howard Minkler served,
and my best recollection, he would have been here in
place at that time, but I really cannot recall with
certainty when he left.
MS. OLIVER:
That's fair enough.
BY MS. OLIVER:
Q Do you recall any other person, the name of
any other person who was in charge of Organic Chemicals
Division beside Mr. Minkler?
MR. FEATHERSTONE:
That information has been
~j~hea 1_ l_JrLcm Certified ortCnd Reporter
154 Couth |_<n Colle Ctreet a \cono, Illinois: 60603
STLCOPCB4026772
Keller
cross (Oliver)
182
elicited at other depositions. Rose, and I suspect it is also in our interrogatory answers, so do the best
you can but don't spend hours pausing.
BY MS. OLIVER:
Q If you don't recall, we are not going to
sit here and wait for you to remember. If you do -
A I would not want to conjecture as this
point.
Q You told us earlier that Monsanto obtained
a gas chromatograph/mass spectrometer in late 1967
and it took several months to get it techniqued down
and be able to use it. How was the technique developed?
A Can you be a little more explicit on the
how?
Q Sure. What did you do when it arrived to
determine how it should be used or how it could be
used? A
We embarked on a self-study program with
members of our unit. Applied Sciences, to read, do
anything possible on the part of the professionals
involved to learn about it and get themselves up to
speed.
Q Was there literature available?
1_. i_JrLan
CjertifieJ
nj Reporter
J34 Soutk {__a RcJie
reet
a \caoo, Illinois- 60603
STLCOPCB4026773
Keller
cross (Oliver)
183
A Yes.
.
Q That you read?
A Yes.
Q Do you recall the names of any articles or
any publications or any literature that you read con
cerning the operation or use of the gas chromatograph/
mass spectrometer?
A A key part of this was the manuals from the
manufacturers which were provided, the instrument
companies.
Q Were you able to buy oneinstrument that
combined both of these units, or did you have to buy
each one separately and then put them together yourself?
A We bought eachseparately and putthem to
gether .
Q Did you discuss or meet or communicate with
any other chemists or scientists concerning what they
might know about this instrument and how it could be
used?
A As a matter of practice, we always do this.
I cannot recall for you specifics of what we went
into at that time.
Q You do not recall whether there were any
other chemists or scientists in the United States in
T"bea I_ Urban
Certified SCrtk ord Reporter
134 Routh \_o 5!!e (R^ic^no, j f I i n o t ^ 60603
STLCOPCB4026774
Keller
cross (Oliver)
184
late 1967 that were aware of this technique and what Monsanto ought to do?
A Not that I am aware of. There were scientists recognized as experts in chromatography or mass spectrometry. We maintained constant competence in terms of state of the art with these two areas, but putting the two together was new enough simply because there were no instruments in this country, so that no one had the combined state of the art we could really go to .
Q Did you ever learn how the combination of these two instruments subsequently developed?
A Primarily as an opportunity through an instrument company to develop sales for a piece of equipment.
Q If you had been aware in 1965 that such piece of equipment were available, would you have re commended that Monsanto purchase it?
A It was our policy to be in the forefront on all skills in the analytical areas case.
Q You mentioned, I think, earlier this morning you believed it was the responsibility of all Monsanto scientists to keep abreast of developments, technological developments.
"Theei |_. bJrbon
-------------------------------------------------------------------------------------------------------------------------------------------------(Certified RhortRnd Reporter ----------------------
134 j__a Rolle Rtreet o icoao, J I! mot S' 60603
STLCOPCB4026775
Keller
cross (Oliver)
185
Through the years, how have you done
that?
A Constant reading of literature, but I must
qualify that my role is more administrative/management
function and I rely upon the professionals and the
experts within the groups responsible for this to keep
on top of it.
Q Would it be fair to say that in your position,
you not only rely on them to keep abreast of new
technology but you consider it their responsibility
and their duty?
A Most definitely.
Q You also mentioned earlier that you and other
people at Monsanto were concerned with the findings
or reported findings of PCBs in the environment by
Dr. Jensen and Dr. Widmark.
Why were you concerned?
A Because there had been no earlier indication
that this existed. It was a complete surprise.
Q Was there anything about the chemical PCB
that led you to be concerned?
A No more so than any of our other products
that might be out in the environment.
Q When you purchased the gas chromatograph and
Tfec* L. U-U
----------------------------------------------------------------------------------------------------------------------------------- Certified Sk ortkand Reporter
--------------------
134 Routk \_o Calle Ctreel
a 'icono, Illinois: 60603
STLCOPCB4026776
Keller cross (Oliver)
186
the mass spectrometer, you mentioned you had to
combine it, using an interface; it was a complicated
step.
Why was it complicated?
A It required design of a system which would
put two experimental instruments together which were
operating on quite different experimental conditions,
and secondly, the gas chromatograph has what is called
carrier gas; for example, helium to move the components
of interest through the chromatographic column and
make the separations.
This carrier gas cannot be introduced
directly into a mass spectrometer because of the
amount of it relative to the material component
being separated.
The big challenge was how to continuously
introduce what comes out of the chromatograph into the
spectrometer free of the carrier gas and that is the
reason why it was necessary to come up with a suitable
and so-called separator for removing of the carrier
gas stream before introducing it. That part was a
technical challenge.
Q Was the technical part of that done within
Monsanto?
1_ UrLwn
Certified Cf ortRnJ Reporter
134 ^outk j__ a 'Rcalle Street a icoao, Illinois- 60605
STLCOPCB4026777
Ke Her
cross (Oliver)
187
A The technical part was done by several
people: For example, Beeraan who is a scientist involved
with mass spectrometry and there was a Beeman separator.
That is one of the earlier separators.
We acquired a separator of this general
description which was then entering the marketplace
at the time these GC/MS's were coming out and we had
to physically ourselves put these three components
together and make them work.
MR. FEATHERS TOME:
Monsanto did not develop the
separator?
THE WITNESS:
We did not develop the separator.
BY MS. OLIVER:
Q But you developed the technology to put the
units together. You did not go outside Monsanto to
talk to other people or find out how other people put
theirs together?
MR. FEATHERSTONE:
You mean the hook-up, the
instrument hook-up to the GC, the separator and the
mass spectrometer?
MS. OLIVER:
Right.
BY THE WITNESS:
A We had some communications with some others.
Again, I don't recall the specifics of that, but it was
14 eo 1__.
______________________ -______________________________________________________________ -
(JrU ReHifieJ RkortRnJ Report
134 Rouln |_o RciHe Rtreet
a lCd><GO, 1 i 11noi9 60603
ZIO 7QO
STLCOPCB4026778
Keller cross (Oliver)
188
our main responsibility and challenge to do that and . get the three together.
BY MS. OLIVER: Q You purchased your units from a German
manufacturer?
A Yes.
Q Do you recall the name?
A The instrument's name is MAT CH4-B mass
spectrometer system, German instrument.
MR. FEATHERSTONE:
That's because none were
available in the United States?
THE WITNESS:
Correct, for use with the gas
chromatograph system.
BY MS. OLIVER: Q When you went about finding a manufacturer
to buy this unit from, what did you do to locate some
one who could sell you a unit? A It was our practice to know what U.S. com
panies could provide and in the way of instrumentation.
We had a good reading on what mass spectrometers might
be available. In our judgment the instrument we are
talking about, the German instrument, was the instrument that should be used for gas chromatograph-mass spectro
meter systems and through this, at about this point in
"Oea 1_. Urban
---------------------------------------------------------------------------------------------------------------------------------- CeriifieJ
ortkjnd Reporter _____________
I3>4 Routii |_o Raiie Rtreet
llJinocr 60603
-r O ^ 7 7 7 ^
STLCOPCB4026779
Keller cross (Oliver)
189
time, an American company bought out the German company
and the name of the American company is V-a-r-i-a-n,
and I believe it is Varian Associates.
Q Did you buy your unit from Varian Associates?
A My best recollection is this was a change
over right at the point we were acquiring it and I
think before we actually took delivery, Varian was the
owner of that system, of that company.
Q Were there other units to look at and make a
selection from?
A No.
Q Your AppliedSciences unit or Analytical
Chemistry group worked on projects not only for
Functional Fluids group, but other groups as well,
is that correct?
A Correct.
Q Before 1967 you do not have a recollection
of doing any projects on any of the Pydraul fluids for
the Functional Fluids group?
A I think I responded to that earlier. It
would only be through projects that would come in
directly to our group and they would handle it and
report out on it without my knowledge.
Q But to your knowledge, there would be none?
------------------------------- ---------------------------------------------------- ---------------
------------------
Thee* |_. UrLan
CeHifieJ
orthond Reporter
134 Routh {_a 5olle Rtreet Rhtc<3c30, Illinois 60603
zn 7cn zzz-n
-------------
STLCOPCB4026780
Keller
cross (Oliver)
190
A To my knowledge. Q Prior to 1967, your Analytical Chemistry
group had a gas chromatograph, is that correct?
A Correct.
Q You testified earlier that some of the plant
manufacturing facilities had analytical laboratories.
Do you know whether gas chromatographs
were in the manufacturing facilities?
A I know regarding some of the facilities, yes.
Q And the facilities that you have knowledge
about, did they have gas chromatographs in their
laboratories ?
A At that period?
0 Prior to
1967.
A Yes .
Q Did your Analytical Chemistry group work on
projects with the manufacturing facilities' laboratories;
A They could and did.
Q I think you testified that in about 1970,
you did some analytical work on samples brought to you
by the business group or the marketing group purportedly
from Johnson Motors.
A Correct.
Q Was that the only analytical work with respect
"Tkeo 1_. Urbcin ------------------------------------------------------------------------------------(Certified RlicrtRnd Reporter ______
134 Rouln |_a Resile Rtreet CR`cc?^o, |!!ino19 60603
STLCOPCB4026781
Keller
cross (Oliver)
191
to Johnson Motors that you recall in the period prior
to 1975?
A That is the only work that I have knowledge
of.
Q Do you have any knowledge that that sampling
was done as part of a program that Monsanto was trying
to start on reclaiming Pydraul fluids?
A Yes, I am aware of it.
Q You are aware that Monsanto considered going
into the business of reclamation of Pydraul?
A Yes .
Q And that was the reason, to your knowledge.
why samples were being taken from Johnson Motors?
A To my knowledge.
Q If we can talk a couple of minutes about your
trip to Europe in '69 when you visited a number of
people -- when you visited Mr. Holden in Scotland and
discussed with him his analytical work on pesticides,
he told you he was finding PCBs interfering with his
pesticide analyses, is that correct?
A Yes.
Q Did you discuss with him or did he tell you
how long he had been doing that work?
MR. FEATHERSTONE:
Pesticide work?
---------------------------------------------------------- ---- . ----- ----------------------
"]~kea 1__.
Certified ortkand [Reporter (54 ^)outh (_a ^)di!e
L i r rx a r. I 1! i n o i ? 60<603
_____
STLCOPCB4026782
Keller
cross (Oliver)
192
MS. OLIVER:
Yes.
BY THE WITNESS:
A He showed us results going back two or three
years. How much he might have been involv ed prior to
that, I don't know.
BY MS. OLIVER:
Q What results did he show you?
A Findings regarding levels of pesticides and
where there would be apparent PCB interferences.
Q Had he identified the interferences as PCBs
prior to 1969?
A To my best recollection, he had not identi
fied. He was basing this on chromatographic findings.
Q Did you have the opportunity to look at his
chromatographic findings?
A He showed us some chromatographic curves, yes.
Q Were you able to determine from those
chromatographic curves the presence of PCBs?
A Not conclusively, no.
(Keller-OMC Deposition Exhibit
No. 1 marked for identification,
5/28/81, TLU.)
BY MS. OLIVER:
Q Dr. Keller, I would like you to look at what
~]~iiei |__ l_JpLxan
(Certified 5^ ortkctnd Reporter
134 ^outn |_a
Street
Rktcotgo. Ulmof'T 60603
--------------------------
STLCOPCB4026783
Keller
cross (Oliver)
193
we have marked as Keller Exhibit No. 1, which is a
.
cover memorandum from you to a number of persons within
Monsanto, referring to a summary of analytical findings,
your European trip, May 1 to 21, 1970. Would you look
at that a minute.
MR. FEATHERS TONE:
Did you want him to read the
entire document?
BY MS. OLIVER:
Q Can you identify this as being prepared by
you, Dr. Keller?
A Yes.
Q Does this exhibit summarize your findings of
your European trip which you discussed this morning?
MR. FEATHERSTONE:
You discussed the 1969 trip?
THE WITNESS:
Yes.
BY MS. OLIVER:
Q Is that the same trip you were talking about?
A No, it is not.
Q You made another trip?
A Yes, correct.
Q That was in May of 1970?
A Yes.
Q What was the purpose of that trip?
A A follow-up trip to visit certain ones later
~j~heci 1_ Olrbon
Certified orthancl Reporter
!54 Routk L_a S^lle Rtreet Rlnic.-T.^o, [IlmoK 60603
--
STLCOPCB4026784
Keller - cross (Oliver)
194
to determine progress made or changes relative to
PCBs .
Q Did you talk to the same people in Europe that you had seen previously?
A Some of the same people. I would have to
have an itinerary in front of me to be able to recall
tha t.
Q Did Mr. Wheeler accompany you on the second
trip?
A Mr. Wheeler accompanied me on one of the
trips, either 1969 or 1970, and another Monsanto
representative on the other trip.
Q Who was the other representative? A A man by the name of Hardy.
Q What was Mr. Hardy9s position with Monsanto? A He was in the role of more of a special
projects assignment person out of the London office.
Q If you would look at the second to the last
page of this exhibit, the paragraph numbered 15, and
just read that a minute.
A Yes.
Q It says: "PCBs were found in fish in the waters
of Scotland back to 1963 as shown by examination of
~[~ keo 1_. Urlscin
---------------------------------------------------------------------------------------------------Certified Ck ortkand Reporter
134 5outk \_a
'Rtreet
. . _ _ III:..:. AnAHA
STLCOPCB4026785
Keller
cross (Oliver)
195
old GC curves. No curves available for earlier years."
Do you recall how you learned that
during your trip to Europe?
A This was through the visit with Holden.
Q This was your second visit with Mr. Holden?
A Yes.
Q Did he show you gas chromatograph curves
dating back to 1963?
A Yes .
Q How is it determined that they showed PCBs?
A This is paraphrasing of what he said was
there, okay?
Q Yes.
A And, again, it is the interferences to the
chromatograms for pesticides.
Q Did he tell you how he made a determination
that these were PCBs?
A I don't recall that he discussed that again.
I think I commented that to my best recollection he
used only chromatographic methods for this work.
Q Did you discuss with him whether his findings
were accurate or not?
A Relative to?
Q Relative to his findings of
PCBs.
TU L. UrU
Rertij'ied <3^r^clnJ Reporter
134 ^outh
Sdlle Rtreet
a iccsgo, | f I inc19 60603
STLCOPCB4026786
Keller cross (Oliver)
196
MR. FEATHERSTONE:
You mean his claims. We
have already established you cannot establish PCBs
identification from a gas chromatograph alone.
MS. OLIVER:
Apparently Mr. Holden thought he
could.
MR. FEATHERSTONE:
Is that a claim?
MS . OLIVER:
Sure, call it a claim.
MR. FEATHERSTONE:
Just 1 ike your complaints
BY THE WI TNESS:
A It was not my impression that Mr. Holden
was claiming that he had identified conclusively PCBs.
He was relating to findings of Widmark and Jensen who
said we have identified certain interferences that
look like this in chromatograms as PCBs.
This prompted him to go back, get his
early chromatograms and say, I guess I see some of
the same interferences; therefore, I've got PCBs.
MR. FEATHERSTONE:
So he was looking back at
1959/1963 chromatograms. He was looking at them in
the late '60s, is that right?
MS. OLIVER:
I am going to object to the question,
Mr. Featherstone. Mr. Featherstone can ask Dr. Keller
questions at his opportunity.
MR. FEATHERSTONE:
Answer my question, please.
:,
"Oea [_. Urban
(Certified RRrthoncI Reporter ----------------------------------------------------------------
134 Soutk |__a Rolle Rtreet a \COOO, | !! i no i ? 60603
STLCOPCB4026787
Keller
cross (Oliver)
197
THE WITNESS:
I had two questions come here.
Could you repeat -
MR. FEATHERSTONE:
Is this Holden analysis of
1963 GC curves an analysis he made in later analysis?
MS. OLIVER:
Same objection.
MR. FEATHERSTONE:
I will ask it later. Go
ahead.
We can play games, go ahead.
MS. OLIVER:
Okay.
BY MS. OLIVER:
O Do you recall any further discussion with
Mr. Holden about the gas chromatographs that you and
he looked at on this trip in May 1970?
A No. We really didn't get into equipment or
methodology specifics. Q You mentioned earlier this morning that you
met Mr. Richardson in 1969 and you discussed with him
his analysis of materials for pesticides and inter
ferences that he found, is that correct?
A Correct.
Q Do you know when he began his work on
analyzing materials for pesticides and finding those
interferences?
A The best I could do on that would be a few
Thea I_ U^n
------------------------------------------------------------------------------------------------------------------------------------ Certified
ortktqncl Reporter
134 Routk |_a 'cRiie Street a \COOO, Illinois- 60603
STLCOPCB4026788
Keller
cross (Oliver)
198
years earlier ahead of our visit.
.
Q And your visit to the University of Utrecht
in 1969, you discussed with them their findings of
PCBs in the Rhine and Netherlands, is that correct?
A Correct.
Q Do you know when they began their work which
led to these findings?
A In their laboratories.
Q In their laboratories? A Again, it was my impression it was a matter
of a very few years ahead of our visit.
Q During that same trip in 1969, I think you
testified that you had discussion with Dr. Widmark
about their possible sources of PCBs that he was
reporting and he thought that PCBs were coming from
paint, from paint on ships?
A Yes.
Q Can you recall. Dr. Keller, Mr. Wheeler and
you discussing any possible sources with Dr. Widmark?
MR. FEATHERSTONE:
The question has been asked
and answered.
BY THE WITNESS:
A No.
BY MS. OLIVER:
""[""bed 1__. turban (RerRied RhortRnd Reporter
134 Routk j_a Rcilie Rtreet
a ic^ko, | I Itnoi? 60603
STLCOPCB4026789
Keller
cross (Oliver)
199
Q You described for Mr. Hynes the non-routine
projects which the Analytical group did regarding
PCBs in the period 1969 to 1973.
What were the routine projects that
were done by your group regarding PCBs during that
period?
A This was in the category of where we had
established suitable gas chromatography/mass
spectrornetry methods and felt confident enough to
go ahead and start using those on certain materials
such as water, effluent discharges, et cetera.
Q Do you know how it was determined where the
samples were to be taken from for you to do your
analytical work?
A No.
Q Do you know what group was responsible for
'
making that determination?
A That would be through the business group.
Q You would justreceive
the samples,I take
it?
A Correct.
Q With respect to the work you did for the
Medical Department in measuring levels of PCBs in
test animals, do you know if any outside groups did
Tlieo j_. IJrLin ----------------------------------------------------------------------------------------------------------------------------------- Certified Sk ortRnd Reporter --------------------
154 Rout!? |_a Rdlle Rtreet lillnoi. 60605
STLCOPCB4026790
Keller
cross (Oliver)
200
the s ame type of work as the Analytical group was doing?
A You are speaking of Monsantoprojects?
Q Yes.
A Not to my knowledge.
Q So to your knowledge, thetesting would be
done by Industrial Bio-Test and the tissues of the
aniraa Is would be sent to your group and you would
analy ze for the PCB level and return them to Bio-Test?
A No, no -- correction on the latter part of
tha t. You are speaking of results when you say return
to?
Q No.
MR. FEATHERSTONE:
The question was what happens
to the tissues. Did you return the tissues to
Bio-Test? That is the way I understand her question.
BY THE WITNESS:
A To the best of my recollection, we did not
return the tissue to Bio-Test.
BY MS. OLIVER:
Q Do you know w hat happened to the tissues
when you had done your analyses ?
A The group in Applied Sciences disposed of
these tissues and I am not prepared to say how they
did this except to say it was not considered to be a
Tlieci (_. Uriwn
Certified
ortRnJ Reporter
134 Routh 1_a Rctlle Rtreet a \cooo, Illinois 60603 31? - 780-333?
STLCOPCB4026791
M*
Keller cross (Oliver)
201
problem because all the PCBs had been removed from
,
the tissues.
Q In the biodegradation studies conducted on PCBs, was the methodology that you followed of using
semi-continuous sludge and feeding an organism into
it and periodically charging it with whatever you are
going to measure for 48 or 24-hour period an accepted
methodology?
A Yes.
Q For biodegradationstudies?
A Yes.
Q What was themethodology available prior to
1969? MR. FEATHERSTONE:
We have already been through
this. We are not going to answer it again now.
MS. OLIVER:
I am not speaking in terms of PCBs.
I am speaking of generally the methodology available
for biodegradation studies.
MR. FEATHERSTONE:
He has already testified to
tha t. MS. OLIVER:
I am talking about the entire method
ology - MR. FEATHERSTONE:
And he has already testified
to that.
-------------------------------------------------------- ------------------------------------------------------------------------ --
TU L.
Certified
orthemd Reporter
134 Routii |__a
lie Street
Illinois 60603
*,!? . 7ft?-333?
--
STLCOPCB4026792
Keller
cross (Oliver)
201
problem because all the PCBs had been removed from the tissues.
,
Q In the biodegradation studies conducted on PCBs, was the methodology that you followed of using
semi-continuous sludge and feeding an organism into
it and periodically charging it with whatever you are going to measure for 48 or 24-hour period an accepted
methodology?
A Yes.
Q For biodegradation studies?
A Yes . Q What was themethodology available prior to
1969? MR. FEATHERSTONE:
We have already been through
this. We are not going to answer it again now.
MS. OLIVER:
I am not speaking in terms of PCBs.
I am speaking of generally the methodology available
for biodegradation studies.
MR. FEATHERSTONE:
He has already testified to
that. MS. OLIVER:
I am talking about the entire method
ology - MR. FEATHERSTONE:
And he has already testified
to that
Thea I_ Urban
r" ,. r. i r-si \ t
STLCOPCB4026793
Keller
cross (Oliver)
202
MS. OLIVER:
You are not going to let himanswer
that question?
MR. FEATHERSTONE:
That's right.
MS. OLIVER:
Certify the question.
BY MS. OLIVER:
Q Dr. Keller, would the rate of biodegradation
that you would find vary depending on the type of
substance, the material that you used? For example,
if you used stream water instead of semi-continuous
sludge, would you expect the rate of biodegradation
to change?
A Yes.
Q In your water solubility tests that you
conducted regarding PCBs, the methodology that you
used was to inject the PCBs into water at 25 degrees
Centigrade or room temperature?
A Correct. Q Was there a standard methodology for a water
solubility test?
A Yes.
Q Was that methodology available prior to 1969?
A For whattypes of materials?
Q For making adetermination of water solubility
of any chemical or compound?
Tinea j_. UT'bc,n
________________________________________________________ 134 Routfi \_o Rolle Rtreet o \cooo, Illinois 60603 *,17 . 7 R7 .*,*,*>7
STLCOPCB4026794
Keller cross (Oliver)
203
A The methodology would have had to have been research. It was not available.
Q For PCBs? A For PCBs at levels we are talking about. part per billion levels in water. Q Am I correct that to your knowledge no bio degradation studies or water solubility studies were undertaken or attempted within the Applied Sciences group of Monsanto prior to 1969 or 1970 for PCBs? A Correct. Q Dr. Keller, were you a member of an internal committee that was established to work on the PCB problem or the PCB claims thatarose in the late 1960s, early 1970? A I was a member of a committee concerned,where my role concerned the analytical parts of certain projects, if that is what you may be referring to.
Can you be more specific as to the committee?
Q Well, for example, was there an informal, at least, committee within Monsanto to discuss and work on the various aspects of the PCB problem which had been reported?
A To my knowledge, that covers an awareness
Jleo L- U^n
Certified Shorthand Reporter
134 Soth 1_a Raile St Skicaoc. {I inoi? 60603
*!? - 782-333?
STLCOPCB4026795
Keller
cross (Oliver;
w 'X
that there were representatives from the business unit..
Medical Department and my operation to put together
whatever was needed. I never viewed this as a
committee, even informal,
Q Were there meetings within Monsanto that'
you attended concerning the various aspects of the
PCB reported findings?
I '4
A We communicated orally and certainly there
were meetings where that was done, yes.
Q Did you participate in any fish toxicity
tests done at Monsanto regarding PCBs?
A No.
jr
MS. OLIVER:
Let me have a minute.
(Brief recess had.)
BY MS. OLIVER:
Q Dr. Keller, in 1970 when you were section manager of the Analytical and Physical Instrument
Developmen t Section, who did you report to? iVd-L-*
A Dr. Tracy Patrick.
Q What position did he have with Monsanto? A Associate Director of Research.
Q In 1971 when you became Manager of Applied Sciences, did you continue to report to Mr. Patrick?
A Yes,
~The<s L- l_Jrbfiri
Certified Cf ortkond Reporter
(34 ^outk |_a ^oile Street
Ck ic&ao, Illinois 60603 312 - 782-3332
STLCOPCB4026796
Keller
cross (Oliverj
^U3
Q You mentioned earlier a group called Environmental Test. When did that come into existence
at Monsanto, to your knowledge? A I believe we covered that in the earlier
testimony as to the time frame for that analytical chemical and environmental --
Q Two or three years before you became manager
of Applied Sciences? A Yes. Q There w as no such group
_. - .
efore 19 6 8 or so? A This ca n be best clarifi
Analyti cal g roup but had
iodegrad ation and related
I see .
Be fore 1968 or '69,
analyses of e f f lue nt from
for environmental purposes?
MR. FEATIIERSTONE:
I am sorry, the time frame
of your question?
MS. OLIVER:
Before 1968, '69.
BY THE WITNESS: A As a general thing for any products?
BY MS. OLIVER:
1_. Urban
Certified Sf> ortRnd Reporter*
1(34 Routk __a
Street
a ICO0O, Illinois 60603
31? - 780-333?
STLCOPCB4026797
.5
Keller
cross (Oliver)
206
Q For any products.
MR. FEATHERSTONE:
Wait a minute. What does any
product have to do with this? Is your question directed
to PCB analysis in the Monsanto plant before 1969?
MS. OLIVER:
Dr. Keller said there was no, to
his memory, PCB analysis before 1968, '69, so I am
asking about environmental testing.
MR. FEATHERSTONE:
For anything?
MS. OLIVER:
For anything.
,
MR. FEATHERSTONE:
How is that relevant to the
lawsuit?
MS. OLIVER:
Can he answer the question?
MR. FEATHERSTONE:
Not unless you convince me
it is relevant. MS. OLIVER:
I am not going to convince you it
is relevant. If you want him to answer, let him
answer. If you don't want him to answer, then direct
him not to answer. Let us not talk about how relevant
it is .
MR. FEATHERSTONE:
Fine, he is not going to
answer.
MS. OLIVER:
Certify the question.
BY MS. OLIVER:
Q To your knowledge. Dr. Keller, before 1968,
Tke. L- Urt* n
Repor-ter
154 So^'tk [_a
O;c~>o. |l' ncK 60605
r
STLCOPCB4026798
Keller
cross (Oliver)
207
was there any group within Monsanto who did any type .
of analytical work with respect to environmental con
siderations for customers of Monsanto?
A Yes.
Q What group was that?
A Again, you are saying anytype of analytical
work?
Q Yes.
A As a customer support?
Q Yes.
A For any types of products?
Q Yes.
A Yes .
Q Are you aware of analyticalwork done by
Monsanto for customers or of functional fluids with
respect to environmental considerations prior to 1968?
MR. FEATHERSTONE:
These are PCB functional
fluids?
MS. OLIVER:
Functional fluids,
MR. FEATHERSTONE:
Limit your answer to PCB
functional fluids.
BY THE WITNESS:
'
A On PCB functional fluids, no,
MS. OLIVER:
I am not limiting the question to
----------------- ---------------------------------------- ------------- -------------------------------------------- -----------------
TU |_. turban
Certified
ortkcmd Reporter*
i34 Routln 1_a ^>alle Street
a \caao, i I11 noi s* 60603
________
STLCOPCB4026799
Keller
cross (Oliver)
208
analytical work for PCBs because I think you have
answered that before. I am talking about any environ
mental work regarding water pollution or environmental
work regarding water pollution for Monsanto customers
of functional fluids.
MR. FEATIIERSTONE:
And read that to be PCB
functional fluids.
MS. OLIVER:
PCB functional fluids, but not
limited to analyses for PCBs.
MR. FEATHERSTONE:
Fine.
BY THE WITNESS:
A The answer is no.
BY MS. OLIVER:
Q Doctor, would you look at Exhibit No. 1
that we have marked. Was that prepared by you after your
trip to Europe in 1970?
A Yes.
Q Was that prepared by you in the ordinary
course of your business?
A Yes.
Q Was that prepared on or about the date of
the memorandum?
A Yes.
----------------------------------------------------------------- .----
-------------------------------- -------- ------- --_
L
Certified
ortkond Reporter
!34 S>utk L* Ralle Street
a iCd^- Illinois 60603
STLCOPCB4026800
Keller direct (resumed)
209
MS. OLIVER:
I don't have anything else.
,
MR. HYNES:
Do you want to go first? I have two
or three questions.
MR. FEATHERSTONE:
Go ahead.
DIRECT EXAMINATION (Resumed)
BY MR. HYNES: Q Dr. Keller, in terms of the inability tech
nically to detect PCBs in any substance in the environ ment that would be analyzed prior to, say, 1967, 1968,
was it any concern to you or your group that there
was an inability to detect PCBs in a substance,that you didn't have a technology to do it?
Was it ever a concern to you? A There was never a need for it.
Q Was it a concern that there were other substances you would be unable to identify because of
the lack of technology prior to 1967, '68 -
MR. FEATHERSTONE:
Wait a minute. Could I have
the question back?
MR. HYNES:
Let me do it again.
BY MR. HYNES:
Q What I am getting at is were you unable to
identify PCBs or any scientist was prior to this new
technology, I think that is what we said. Was it a
------- --
------ ----------------------------------------------------------------------------------------------
Thea 1_. I_Irban
Certified
ortkanj Reporter
134 Sutk |_a
Street
o IC&QO, Illinois- 60603
.------------
STLCOPCB4026801
Keller direct (resumed)
210
concern within your group that there was an amount of
chemicals, an amount of compounds that you would not
be able to identify because of the lack of technology?
MR. FEATHERSTONE:
He just answered that with
respect to PCBs.
MR. HYNES:
I am talking about other compounds,
other than PCBs.
BY MR. HYNES:
Q Was there a concern there with your inability
to identify them?
MR. FEATHERSTONE:
Unknown samples?
MR. HYNES:
Yes.
BY THE WITNESS:
A We were always concerned as information was
needed of that type.
BY MR. HYNES:
Q With members of your group or any other
research groups within Monsanto, was it a part of
their function to research and develop new technology
other than for the internal control use like you said
that one division was in the plant?
A Yes.
Q Was that group within the one you worked in?
A Could we clarify what group this is?
' TU L. U^Un
----------------------------------------------------------------------------------------------------------------------------------- Certified
orttiond Reporter
.
134 Routii [_d RdHe Rtreet
a i coo o, { I iinois 60603
STLCOPCB4026802
Keller direct (resumed)
211
Q What I am talking about is the Applied
Sciences group, make it the Research and Development
group within the Organic Chemicals Division. I
think that would have been the group that you would
have worked in throughout your career at Monsanto,
if I am correct.
A Correct.
Q Would any research within the Research and
Development group of Monsanto, is there any entity
or unit there set up on developing research, on
developing analytical equipment?
A Other than Applied Sciences?
Q Were there any other divisions orgroups
within Monsanto who had that function?
A The one I testified earlier on the Physical
Sciences Center.
Q Would they be the group thatwould assume
that Monsanto developed this new technology about
GC/MS, would that have been the group that would have
developed it within Monsanto?
MR. FEATHERSTONE:
Objection to the question.
MR. HYNES:
If it had been developed within
Monsanto, would he have developed it?
MR. FEATHERSTONE:
You can go ahead and answer
Tk eo 1__. t_Jrkan
_____________________________________ CeT-tified orthand Reporter
134 |_a Street '
RkiC^go, Illinois' 60603
-----
STLCOPCB4026803
Keller
direct (resumed)
212
the question. BY THE WITNESS:
.
A It could have been developed by any of the
groups we have discussed. Again, it would come back
to a need basis.
BY MR. HYNES:
Q In other words, if someone within Monsanto,
some group within Monsanto said we need to identify
compound X, go develop some technology to do it, that
is how it would come back, other than just pure
research, come upon it in a laboratory and just working
on it?
A Yes, right.
MR. FEATHERSTONE:
I take it assuming Monsanto
had the capabilities?
THE WITNESS:
Yes, pure technology.
BY MR. HYNES:
Q You said with regard to the Widmark-Jensen
article that you were surprised of their results
because there had been no earlier indication that
PCBs were in the environment, is that correct?
A Correct.
Q Was your surprise at theresults,
the ability
of Widmark and Jensen to actually identify PCBs, or was
-------------------------------------------------------------------------------------
""0ecl 1_. l__Jrb<3n
Certified ortkcand [Reporter
134 Lo S^le reet
CS't^-"30. U`inoic 60603
--------
STLCOPCB4026804
Keller
cl:' rect (resumed)
213
it surprise there were PCBs within the environment?
A My first interest, and I wouldn't necessarily
say it was surprise but interest, was their capability
| to make determinations of this type with the GC/mass spectrometer system.
Q I think you used the word surprise, but was
your surprise the fact that there was technology out
there but you didn't know about it before?
A Surprise :ay not bethe right
word.
1 Q Impressed?
N
A Impressed.
|
j Q You earliersaid that, paraphrasing, Monsanto
i
took pride in having top technology available to it
in their laboratories and research. Do you recall
any discussions within Monsanto where you were present
i or heard about where somebody got called on the carpet
i
because you didn't know about that technology that
these Swedes had for at least a year or so before
the article was published?
A No.
Q Prior to 1967, the technology being developed
at the GC/MS, would a competent chemist in running
analysis of a product, of some sample, using a gas
chromatograph, would they be, am I correct, they would
(_. IJrLn
Reriif.ed RhortRnd Reporter
L'-o c 1 le Rtreet
cu
60603
. 7,co_*,
STLCOPCB4026805
Keller
direct (resumed)
214
find some unknown peaks, assuming PCBs were in this
substance and they don't know PCBs were there, would
they find some unknown peaks identifiable, is that
correct?
A Correct. O Would thatchemist beable to make an
educated guess that these were PCBs given no other
information?
A No .
Q If the chemistsuspected PCBs were in the
substance which was being analyzed, would they be
able to guess that was PCBs but not really definitely
be able to say that it was?
MR. FEATHERSTONE:
I'm going to object to the
form of the question.
MS. OLIVER:
I'm going to object, too, calling
for speculation.
MR. FEATHERSTONE:
Yes.
BY THE WITNESS:
A That's what it would be, a guess.
BY MR. HYNES:
Q It would be a guess? To your knowledge, did anybody guess
like that prior to, did you ever see any published
----- .----------------------------------------------------------------------------------------- r-J
1~lien |__ . 1__
anj [Reporter
C^.hiC.:ano, jliimcMS 6C603
STLCOPCB4026806
Keller
direct (resumed) cross (Oliver resumed)
215
report or opinions at some of these symposiums that
someone said these might be PCDs but we can't tell?
A Not prior to Widmark and Jensen.
MR. HYNES:
I don't have anything further
MS . OLIVER:
Could I ask one?
MR. FEATHERSTONE:
Yes.
CROSS EXAMINATION (Resumed)
BY MS. OLIVER:
Q In trying to identify these peaks on these
gas chromatographs as PCBs, am I correct that the
peaks depending on the mixture or the compound could
move to different locations on your graph?
MR. FEATHERSTONE:
Do you understand that?
THE WITNESS:
I would like a little more
clarification.
BY MS. OLIVER:
Q Now I am in trouble.
MR. HYNES:
You mean just using the GC, not the
mass spectrometer?
MS. OLIVER:
Right.
BY MS. OLIVER:
Q Reading the gas chromatograph, my understand
ing is that it gives you some peaks that you could
look at and whether you were able to identify what
Tkec' 1_. l^Jrbon CjertVied RkortO^nd Reporter
134 Rcuik 1_a lie Rtreet a >cooo. Illinoit 60603
STLCOPCB4026807
Keller - cross (Oliver resumed) - cross (Featherstone)
216
those peaks are or not is a question, I guess, is that
right?
A Correct.
Q Depending on the mixtures or the chemicals
that you are analyzing, would, for example, the PCB
peaks move into different ranges of the graph depend
ing on the different mixtures or different isomers
of PCBs that are in that compound you are analyzing?
A Yes.
Q That would further complicate the identifi
cation, is that right?
A Yes.
Q Would that problem exist in the IR
spectrometer?
A Of the same general nature, but for dif
ferent reasons.
Q But it would still cause a confusion in
reading?
A Yes.
MS. OLIVER:
I don't have anything else, thank
you,
MR. FEATHERSTONE:
I have two questions.
CROSS EXAMINATION
BY MR. FEATHERSTONE:
Jr-oo [_ U^n
C,evti: ,eJ SL-r-tLprd Reporter
134 CLuL [__,, S^'e Street
CScaac. | Ik-ci-; 6C603
STLCOPCB4026808
Keller
cross (Featherstone)
217
Q Doctor, you testified that taking an unknown
sample, unknown chemicals, an analytical chemist using
a gas chromatograph alone could not determine the
presence of PCBs in that sample, is that correct?
A Correct.
Q Why is that?
A Because it is not an absolute method for
determining chemical structure.
Q My understanding of a gas chromatograph is
that it prints out, if you will, a fingerprint or
chromatograph off the components, is that correct?
A Correct.
Q From the peaks thatcounsel havereferred
to in their questions, can you tell from a particular
peak on that chromatogram what the component is?
A No .
Q What does the peak tell you?
A The peak tells you that you have one or more
components under that peak.
Q You say one or more components. I take it
from that that a peak doesn't necessarily refer to
one component.
A Correct. Q Can you tell from just looking at the
----------------------------------------------------- -- -------------------------------------------------------------------------
~Tbec> I_ Urban
_e^iI* led
orthord [Reporter
! 30 j_a Street
(llinoso-ncaoc,
60603
_________
STLCOPCB4026809
Keller
cross (Feathers tone)
218
chromatogram itself or one peak on the chromatogram . how many components a peak refers to?
A No . Q So it could be two, three, four, five? A Any number. Q Since you cannot tell from a peak on that chromatogram what the component is, I take it the gas chromatograph does not completely separate all compounds in a sample. A Correct. Q Is it true that chlorinated hydrocarbons and other compounds that are not chlorinated hydrocarbons may be contained under the same peak? A Very possible. Q And that is why you cannot tell from a chromatographic peak or chromatogram itself why some thing is not a chlorinated hydrocarbon? A Correct. Q For that purpose, you used the mass spectro meter hooked up to it? A Yes. Q Doctor, you were examined to some extent or at some length about the infrared spectrometer, is that the proper instrument?
TU, 1_. Urban
---------------------------------------------------------------------------------------------------- ;ed Rkortlanci Reporter
13^ Routn |__a Resile Rtreet
CRicaac, [llinoi? 60603
STLCOPCB4026810
Keller
cross (Featherstone)
219
A Correct.
Q You testified that a sample analyzed by
use of that piece of equipment with a PCB sample
would show perhaps an aromatic compound on a carbon
hydrogen bond, is that correct?
A A carbon chlorine bond also, perhaps.
Q Why couldn't you tell from that readout,if
you will, what the compound is?
A Because a mixture of materials where the
chemical structures would use these examples you
mentioned in different ways than the structures could
not be identified as to components.
Q Is it fair to say then the readout you
would get from the infrared spectrometer shows you
the various components but doesn't, if you will,
draw a picture as to how they are put together?
A Correct.
Q And you need that picture to be able to tell
you what the structure is?
A Correct.
Q And therefore, what the chemical is?
A Correct.
Q Doctor, hasMonsanto anytime in the '60s
before it purchased the separator
unit thatwas used
~[~l~ieo |__. Urban
_________ _________________________________________________ _____
Reporter
134 ^Jouth |_,-j ^dle Street
(^hic.or'o, |iimoi9 60603
----
STLCOPCB4026811
Keller cross (Featherstone)
n* I
220
to join the gas chromatograph and the mass spectrometer
internally developed such a separator unit?
A No.
Q Do you know of anybody of any expertise in
Monsanto that could have developed such a unit?
A No.
Q Doctor, I want to show you what wasmarked
as Exhibit 1 to your deposition and I want to direct
your attention to what counsel for OMC showed you
earlier, which is a paragraph numbered 15 which you
have identified pertains to a conversation you had
with, I guess it is Dr. Holden?
A Correct.
Q Did Dr. Holden tell you that in 1963 when
he was doing his research and obtained a gas
chromatograph printout in 1963 when he identified
interference in those printouts, did he tell you that
in 1963 he identified those interferences as PCBs?
A No.
Q When did he tell you that he thought those
interferences were PCBs?
A After the Widmark-Jensen work.
Q So that he was, by going back to his old
chromatographs, pulling them out and looking at them
TU [ UrL
Ce RJ R
I 3 ^outt |_a
Street
C ^ tcoo c-. I ilinoi-r 60633
STLCOPCB4026812
Keller - cross (Featherstone)
221
again?
A Correct.
Q Doctor, you stated that in the late 1960s,
early 1970s, you made it a practice to generally
follow the literature in your field.
Were you following at that time the
literature published by analytical chemists reporting
or claiming to report the presence of PCBs in the
environment?
A Yes.
Q Were thesereportspublished reports
identify
ing the higher chlorinated isomers in the environment?
A Yes .
Q You testified earlier that you hadthis
European trip, in fact, your trips in which you met
with analytical chemists. Were the analytical chemists
that you met with in 1970 also reporting finding the
higher chlorinated isomers, that is, five chlorine
atoms or more,than they had been in 1969?
A Yes. Q Did you have discussions , Doctor, either formally or informally with other than analytical
chemists during the European trips , and that would
be analy tical chemists outside of Monsanto?
"T^ec? [_.
(3er'tfiieI J
Reporter
I JA y outr j_a *Cvnl!e Street
[ I! no!: 60605 "7 D -~i 7 7 7 0
STLCOPCB4026813
Keller
cross (Feathers tone)
222
A Other than those on the European trip?
Q Yes.
A Yes, wealways maintainedcommunication with
analytical chemists.
Q And didthese analyticalchemists in the
late '60s, early 1970s, tell you what isomers or PCBs
they were finding, if any?
A Yes.
Q Which were they? A The high chlorinated PCBs, five chlorine and
higher.
Q Doctor, when you say higher chlorinated isomers w ith the five chlorines and above, is that a
particula r Aroclor and higher, does that convert to
a particu lar Aroclor?
A No .
Q Are there certain Aroclors that do not have five chlo rine atoms among their isomers?
A Yes .
Q Which are those? A The lower chlorinated products.
Q Such as 1242? A Yes .
Q Doctor, you testified that in 1968 Monsanto
------------------ ----------------------------------------------------------------- ---------
"Thee I_ Urbdn
Ce-ti 'Ct-f Rhorthand Reporter
i3>4 Routk 1_a RbHe Rtreet
rb_(n-- I! I inois dO603
STLCOPCB4026814
Keller - cross (Featherstone) - redirect
223
was developing methodology for the use of a gas
chromatograph/mass spectrometer unit that had been
purchased.
Did different methodologies have to be
developed for different types of samples?
A Yes.
Q Did you do a different methodology for a soil sample as opposed to a water sample, for instance?
A Each one was a separate project.
Q When you say each one, does that include an air sample?
A Yes.
Q Sludge? A Yes .
Q Animal tissue s ample? A Yes.
MR. FEATHERSTONE:
I have no further questions.
MR. HYNES:
I have one, I think maybe two.
REDIRECT EXAMINATION
BY MR. HYNES:
Q With regard to your biodegradation studies
which you did or the work you did on biodegradation,
did you know of any groups or persons outside Monsanto
which attempted to verify or duplicate your study?
_____
eo L Urban
ified imj ["Reporter--------
!3v | p
Street
jlhnots 60603
STLCOPCB4026815
Keller - redirect - recross (Oliver) - redirect (resumed)
224
A What period?
Q Any period subsequent to your study.
A I don't have personal knowledge of work of
this type. I suspect work was done, but it is con
jecture .
Q You suspect work was done but you have never
seen the published results or discussed it with anyone
who did it, yourself?
A Personally, I have not.
Q Do you know of anyone in Monsanto who has
mentioned it to you?
A No.
MR. HYNES:
Thank you.
RECROSS EXAMINATION
BY MS. OLIVER:`
Q Dr. Keller, do you have any reason to believe
that the results of your biodegradation studies in
1970 were inaccurate in anyrespect?
A No.
MS. OLIVER:
I don't have any further questions.
REDIRECT EXAMINATION (Resumed)
BY MR. HYNES:
Q Doctor, youtestified that your Analytical
group did water solubility testing in 1969.
Were
-------------------------------------------------- .
---------- -----
----------------------------------------------------,--
Tine' |_.
0Cje~lr;e
J RepOT-tei*
a'ppoutn j__ 'ppaHe 'Street
C'k c,5nc: iiiinoi? 60603
_________
STLCOPCB4026816
Keller
redirect (resumed)
225
the water solubility characteristics of PCBs and
Aroclors at Monsanto known at Monsanto prior to the
time of your study?
A Yes.
Q How was that known?
A Well, practice of any of our research chemists
and scientists developing new products, processes, to
know solubility properties of the products and materials,
reactants.
Q And the tests that you did in 1969, were those to develop the low level solubility analysis
that you needed to do with the biodegradation tests?
A Yes,
MR. HYNES:
I have no further questions.
MS. OLIVER
No questions.
MR. HYNES:
Thank you.
(Witness excused.)
FURTHER DEPONENT SAYETH NOT. . .
[_ Ur^n
[Reporter
134
^(3lie S>tveet
(^.jo ic<? vo. |Hi note 60603
STLCOPCB4026817
226
IN THE UNITED STATES DISTRICT COURT FOR THE NORTHERN DISTRICT OF ILLINOIS
EASTERN DIVISION
THE UNITED STATES OF AMERICA Plaintiff
vs OUTBOARD MARINE CORPORATION AND MONSANTO COMPANY,
Defendants
No. 78 C 1004
I hereby certify that I have read the foregoing transcript of my deposition given at the time and place aforesaid, consisting of Pages 1 to 225, inclusive, and I do again subscribe and make oath that the same is a true, correct and complete transcript of my deposition so given as aforesaid, as it now appears.
Subscribed and sworn to before me this ______ day of , A . D. 19 81
Robert E. Keller
Notary Public
^7c.uir. _a
^^Peet
o, ?| !! fno! 60605
STLCOPCB4026818
227
UNITED STATES OF AMERICA
NORTHERN DISTRICT OFILLINOIS EASTERN DIVISION STATE OF ILLINOIS COUNTY OF COOK
) )
) )
)SS:
I, Thea L. Urban, a notary public in
and for the County of Cook and State of Illinois, do
hereby certify that ROBERT E. KELLER was by me first
duly sworn to testify the whole truth and that the
above deposition was recorded stenographically by me
and was reduced to typewriting under my personal
direction, and that the said deposition constitutes
a true record of the testimony given by said witness.
I further certify that the reading
and signing of said deposition was not waived by the
witness and his counsel.
\
I further certify that I am not a
relative or employee or attorney or counsel of any
of the parties, or a relative or employee of such
attorney or counsel, or financially interested
directly or indirectly in this action.
IN WITNESS WHEREOF, I have hereunto
set my hand and affixed my seal of office at Chicago,
Illinois, this ______ day of June, A.D. 1981.
Notary Public, Cook County, Illinois. My commission expires May 31, 1983.
"Tl'iet.i j__. (^JrlDcin
L ^ RR-tRrd Reporter
I5'i Routr [_l5 Rode Rtreet CRic^no. j ! i inoi^ 60605
STLCOPCB4026819