Rapid Separation of Polychlorinated Biphenyls from DDT and Its Analogues on
Silica Gel
by Diane Snyder* and Robert Keinert U.S, Fish and Wildlife Service Great Lakes Fishery Laboratory Ann Arbor, Michigan 48107
Polychlorinated biphenyls (PCB's), which are used in indus try worldwide (1), have been found as residues in numerous wild life species '(2-7) . Because of the similarity in chemical char acteristics, PCB compounds interfere with gas liquid chromato graphic (GLC) analysis of certain chlorinated hydrocarbon insec ticides (8). In the present study, we sought a rapid microanalytical procedure for separation of PCB's from DDT and its analogues before analysis with GLC. A small silica gel column was found to be suitable for removing two of the Aroclor series of PCB's (1254 and 1260) from DDT and its analogues.
Materials
Silica gel used for the columns was grade 950 activated des iccant, 60-200 mesh, from the Davison Chemical Division of W. R. Grace, Baltimore, Maryland. Pentane and benzene, distilled in glass grade, were from Burdick and Jackson Laboratory, Inc., Muskegon, Michigan. Commercial PCB preparations containing 54 and 60 percent chlorine (Aroclor 1254 and 1260) wefe from the Monsanto Organic Chemicals Division of the Monsanto Co., St. Louis, Missouri. Standards for DDT and its analogues (DDT, DDD, DDE) were from the U.S. Public Health Service Pesticides Repository, Pesticide Research Laboratory, Perrine, Florida.
The Method
Transfer silica gel from a freshly opened can to a glass stoppered bottle and add enough pentane to cover the silica gel with at least 12 mm of pentane. If the silica gel has been pre viously exposed to air, reactivate it by placing it in an oven at 200 C for 8 hours before mixing it with the pentane.
Quickly add the mixture of silica gel and pentane to a glasswool stoppered column (1.0 cm ID x 20 cm long). A useful tool for packing the column is a disposable pipette from which the narrow portion of the tip has been removed. Small amounts of silica gel
1/ Present address: Johns Hopkins School of Hygiene, Department of Population Dynamics, Baltimore, Maryland.
Bulletin of Environmental Contamination & Toxicology, Vol. 6, No. 5,1971, published by Springer-Vcrlag New York Ine.
027587*
TOWOLDMONOQ54289
.
are drawn into the pipette with a rubber bulb, and expelled into the column. Gentle tapping of the column facilitates packing. Always keep enough pentane in the column to ensure that the silica gel being added will filter through the pentane, thus eliminating air bubbles. The column must be free of air bubbles or breaks in the packing to ensure proper separation of the DDT complex from the PCB's. A length of 7.7 cm (about 3 g dry weight) of silica gel is required for each column.
Wash the column with 5 ml of pentane. Place 1 ml of sample in pentane or hexane on the column. Rinse the tube which contained the sample twice with 1-ml portions of pentane and place the rinse on the column. After the sample and rinse have been absorbed, collect the following solvent fractions separately in two 50-ml tubes:
Fraction
Solvent
Ml collected
Chemical eluted
A Pentane 1-38 PCB's
B
Benzene
39 - 75
DDT and its analogues
Concentrate each fraction to the desired volume and analyze
with GLC.
If the amounts of PCB or insecticide put on the column are large, poor separation results; therefore, only the amounts necessary for determination by GLC analysis should be passed through the column.
Operating conditions for GLC and the methods for extraction and cleanup of fish samples before the extracts are placed on the silica gel column were described by Reinert (9).
Concentrations of Aroclorsare determinedby planimetric
readings of the GLC chromatograms. Areas for all the PCB compo-
nents collected in the pentane fraction are compared with the areas
for known amounts. This method yields a standard curve that is
linear on semilog paper.
.
Efficiency of the Method
Efficiency of the silica gel column was measured by deter mining percentage recoveries when known amounts of Aroclors 1254 and 1260 and the DDT complex were washed through the column (Table 1). Fraction A recoveries for 1254 and 1260 averaged 97 and 102 percent, respectively. No peaks with retention times similar to those of DDT and its analogues were found in fraction B.
Measured amounts of Aroclors 1254 and 1260 were added to hexane extracts from fish. The fish--one coho salmon, Oncorhynchus kisutch, and two lake trout, Salvelinus namaycush, from Lake Michigan--contained substantial concentrations of DDT and its
i t !
:
' '
;
, | \
; 1
j
j I | :
; ; j
j
*
,
*' '
j
} ;
: ;
( j
Percents*: and t_h
Fraction j chemical
Fraction A
Aroclor 1 Aroclor 1
Fraction B
pp DDE op DDT pp DDD pp DDT
analogues, analyzed wcolumn effi its analog-.
cleanup of 1254 are s.
The s separates Little pri the small taneously achieved i tative rec
0275075
TOWOLDMONOQ54290
TABLE 1
Percentage recoveries for known amounts of Aroclor 1254 and 1260 and the DDT complex after separation on silica gel columns
Fraction and chemical
Concentration (lX10~8g/ml)
Humber of trials
Percentaqe recovery
Average
Range
Fraction A
Aroclor 1254
50.0- 100.0
15
97 86-118
Aroclor 1260
50.0
13 102 80-130
Fraction B
pp DDE op DDT pp DDD pp DDT
4.0- 10.0 0.5- 10.0 0.5- 10.0 4.0- 10.0
15 12 12 12
89 72-110 93 78-114 96 83-114 97 72-118
analogues. Three samples of each of the spiked extracts were analyzed with GLC after separation on silica gel. The silica gel column effectively separated Aroclor 1254 and 1260 from DDT and its analogues in extracts from fish (Table 2).
Chromatograms taken at various stages during the silica gel cleanup of the hexane extract of a lake trout spiked with Aroclor 1254 are shown in Figure 1.
The silica gel column described here rapidly and efficiently separates the two Aroclors tested from DDT and its analogues. Little prior preparation of the silica gel is needed. Because of the small size of the columns, numerous samples can be run simul taneously on individual columns in a small area. Separation is achieved in about 1 hour. Reproducibility of results and quanti tative recoveries from samples were good.
387
0275876
TOWOLDMONOQ54291
TABLE 2
Percentage recoveries from silica gel columns for Aroclors 1254 and 1260 and the DDT complex in hexane extracts from coho salmon and lake trout
Species and chemical
component
Percentaqe recovery
Concentration
Fraction A
Fraction B*
{1X10 g/ml) Trial Trial Trial
Trial Trial Trial
1 23
123
Coho salmon
Aroclor 1254 pp DDE op DDT pp DDD pp DDT
Lake trout
Aroclor 1254 pp DDE op DDT pp DDD pp DDT
Lake trout
Aroclor 1260 pp DDE op DDT pp DDD pp DDT
50.0 8.0 1.0 1.0 4.0
50.0 13.0
1.0 2.0 6.0
50.0 10.0
1.0 1.0 5.0
108 108 108 -------
---
90 90 100 -------
---
130 -
-
120 -
-
110 -
-
- --
100 72 100 100
94 62
100 100
85
125 114 100
---
96 76 100
80 100
80
87 87 67
91 91 82
---
80 90 110 83 100 100 100 83 83 89 89 no
* Percentage recoveries for the DDT complex were calculated by comparing the amounts of insecticide found in the hexane ex tracts from fish with the amounts found after the separation procedure on silica gel columns.
UJ Q a 0. ol
<
O.P'DDT
0275877
TOWOLDMONOQ54292
M MM
Mo Ow Oo Ho |
0275878
Figure 1.
Chromatograms of the hexane extract of a lake trout before and after the addition of C.5 yg of Aroclor 1254. (A) Hexane extract of a lake trout after the initial cleanup (9), showing DDT and its analogues. (B) Hexane extract after addition of 0.50 ug of Aroclor 1254. (C) Pentane fraction of the hexane extract after cleanup on silica gel, showing Aroclor 1254,. (D) Benzene fraction of the hexane extract after cleanup on silica gel, showing DDT and its analogues.
TOWOLDMON0054293
References
(1) C. G. GUSTAFSON. Environ. Sci. and Tech. 10, 814 (1970)
(2) T. W. DUKE, J. F. LOWE, AND A. J. WILSON, JR. Bull. Environ Contain, and Tox. 5., 171 (1970)
(3) A. V. HOLDEN, and K. MARSDEN. Nature. 219, 1274 (1967)
(4) D. C. HOMES, J. H. SIMMONS, and J. O'G. TATTON. Nature. 216, 227 (1967)
(5) S. JENSEN, A. G. JOHNELS, M. OLSON, and M. GOTTERLIND. Nature. 224, 247 (1969)
(6) J. H. KOEMAN, M. C. TEN NOEVER DE BRAUW, and R. H. DE VOS. Nature. 221, 1126 (1969)
(7) R. W. RISEBROUGH, P. RIECHE, D. B. PEAKALL, S. G. HERMAN, and M. N. KIRVEN. Nature. 220, 1098 (1968)
(8) L. REYNOLDS. Bull. Environ. Contam. and Tox. , 128 (1969)
(9) R. E. REINERT. Pest. Monitoring J. 3_, 223 (1970)
I l>
One of insecticide of animals, constant th reaches a p and excreti mates intak of excretic lizing enzy enzymes car. stances inc carbon has because of
The pu of detoxica dieldrin rt
Female ment. The Laboratory lism cages tate sepan
The l: six groups 0 and 1 g body weigh mixed cont a tracer, times the
Conduct requiremen Dakota Sta
2 Supplie 2 ppm of t 1,4,4a,5,6 (HEOD).
Bulletin of En* Vol. 6, No. S, 1`
0275079
TOWOLDMONOQ54294