708 CHAPTER 52 1959 Guide Table 5 .... Exhaust Requirements* for Grinding, Polishing, Buffing, Scratch Brushing Abrasive Cut-Off Wheels, Grinding and Polishing Belts (Mr Volume; 4500 fpm in all branches.) (2-m. water suction at average hood.) Grinding or Cut-off Wheels Buffing, Polishing, and Scratch Brushing Wheel (dial, fa. Max. Width* In. (die) In. Cfm Wheel (din). In. Max Width* In. (dia), In. Cfm -9 19-16 17-19 20-24 25-30 31-38 IK 2 3 4 5 6 3 225 4 390 -9 2 4H 500 10-16 3 5 610 17-19 4 6 880 20-24 5 7 1200 25-30 6 3H 300 4M 500 5 610 5K 740 6K 1040 Horizontal Single Spindle Disc Grinders Horizontal Double Vertical Single Spindle Spindle Oise Grinder* Oise Grinders Wheel Brandi (dial (dia) In. In. Cfm Wheel Brandi (dia) (dia) K In. Cfm Wheel Brandi (dia) (dia) In. In. Cfm -12 13-19 20-30 31-36 3 4 5 6 225 390 610 880 ' -19 20-25 28-30 31-53 54-72 1-5 1-6 1-7 2-6 4-8 610 880 1200 1760 6240 -20 21-30 31-53 54-72 1-4H .2-4 2-6 3-8 500 780 1760 3120 GBINDING OB POUSHING BELTS: To 3 in. wide--3 in. branch, add H >n- to branch diame ter for each 2 in. or fraction increase in belt width over 3 in. * locreeae breach (LZ in.| bat not less than H in., tor each 1 in. in- eicese in width over dimension noted. the air flow. For conveying of solid- particles, velocities shown in Table 8 include a reasonable factor of safety and, consequently, design velocities 'may therefore be ad justed as required to permit use of commercial pipe sizes that are available generally in 14-in. diameter steps through 6-in. diameter, 1-in. steps through 16-in. diameter or larger, and 2-in. diameter steps for large diameters. For contaminants other than solids, conveying velocities are based on a consideration of the higher resistance and lower first cost of smaller diameter ducts against higher first cost and lower resistance of larger diameter ducts. Main ducts connecting two or more branches are sized by the same procedure as for branches. The main should be designed for the total exhaust volume to be handled through all branch ducts. Where exhaust systems handling solids are to provide for a substantial increase of future capacity, required conveying velocities can be maintained by: 1. Providing open end stub branches in the main through which air will be admitted into system until future connection is made. The volume admitted into the main can be adjusted to required air flow rate (cfm) by use of a blast gate or orifice plate in such stub branch. 2. Arranging the system layout so that exhaust from future points can be picked up by a separate main that will run directly to the fan or air cleaning equipment inlet. CALCULATION OF SYSTEM PRESSURE LOSS The pressure loss of the system includes entrance loss" as air is accelerated through the hood to a branch duct connection, resistance losses of ducts,4* elbows, and junc tions, and acceleration or deceleration losses from ve- Taperedbooddata from Reference 43. Weatherhood data from Reference 44 Fig. 2 .... Exhaust System Design Datau locity changes within the system. Chapter 21 includes data on duct resistance and on resistance of elbows, and provides sample calculations. In exhaust systems, either the equal friction method (illustrated in Chapter 21) or the use of blast gates in the branches to equalize pressure loss of all runs is employed.*- Data on losses for hood entrance, branch entry, transi tions, and weather hoods are given in fig. 2. The static pressure in branch ducts close to the hood connection is frequently referred to as hood suction. It is the sum of the branch velocity pressure and the hood entrance Io6S. CONSTRUCTION SPECIFICATIONS FOR LOCAL EXHAUST SYSTEMS Correct design and competent installation of sheet steel ducts and hoods, are necessary for the proper functioning of any exhaust system. The foDowing specifications are those recommended in the Industrial Ventilation Manual." General . All exhaust systems shall be constructed with the materials recommended herewith and shall be installed in a permanent Industrial Exhaust Systems 709 Table 6 ..Ventilation Rates for Open Surface Tanks*-*7 Minimum Ventilation Rote Cfm Per Sq Ft Hood Opening Endodng Hood Canopy Hood Minimum Ventilation , ate 1)Cfm Per Sq Ft Tank t Lateral Exhaust (Not* W/t = Tank Width ^ TIO Tank length One Open Two Open Three Open Four Open W/l 0-0.24 Side Side* Side* A8 W/l 0.250.49 AB W/l 0.50- 1.0 AB Minimum Ventilation Kate Cfm Per 5q Ft Hood Minimum Ventilation Rate Cfm Per Sq Ft Tank Area Lateral Exhaust (Note I) W/t = Enclosing Hood Hood !"**"**. Tank Length One Open Side III O <6 Three Four Open Open Sides W/l 0-0.24 AB W/L 0.250.49 AB W/l O.SO- 1.0 AB Plating Chromium (Chromic Acid Mist). 75 100 125 175 125 175 150 200 175 225 Arsenic (Ar sine) .............. 65 90 100 150 90 130 110 150 130 170 Hydrogen Cy anide.............. 75 100 125 175 125 175 150 200 175 225 Cadmium.... 75 100 125 175 125 175 IS) 200 175 226 Anodizing. 75 100 125 175 125 175 150 200 175 225 Metal Cleaning (Pickling) Cold Acid Hot Acid......... 65 90 100 150 90 130 110 150 130 170 75 100 125 176 125 175 1S4J 201 175 225 Nitric and Sul furic Acid... 75 100 125 175 125 175 150 20C 175 225 Nitric and Hy drofluoric Acid.................. 75 100 125 175 125 175 150 200 175 225 Metal Cleaning (Degreasing) See Note 2 and Ref. 38 and 39 Metal Cleaning (Caustic or Electrolytic) Not Boiling... Boiling................ Bright Dip (Ni tric Acid). . Stripping Concentrated Nitric Acid.. Stripping Cone. Nitric and Sul- furic Acid... 75 Salt Baths (Molten Salt).. - - SO Salt Solution (Parkerise, Bonderize, 90 Boiling................ 75 Hot Water (if vent, desired) Not Boiling. Boiling............ 50 75 100 125 175 125 175 1501 200 275 225 75 75 125 60 99 75 100 90 110 90 100 150 9C 13C 110 15C 130 170 100 125 175 125 175 150 200 175 225 75 75 125 60 9C 75 100 90 110 100 125 175 125 175 150 200 175 225 Note 1--Column A raters to teak with tood along one side or two parallel sides when one hood is it a wall or a baffle ranging length of tank and as hifh teak is wide; also to i-tit. with exhaust along line with -- i-awning tank width in WJL Ratio- Column B raters to free standing tank with hood along one sideor two parallel sides. Koto 3--Complete control of the vapon and mist from degreasing operations requires the same ventilation rates as recommended for pickling- However, the solvents employed in degreasing operations are relatively volatile, and the solvent loss caused by evaporation increases rapidly as the exhaust rate at the tank iwarrnirn For this reason perfect control is usually sacrificed in favor cl tower solvent evaporation rates. Where solvent loss does not present an important cost or operating problem, the exhaust rates given for pickling should be adhered to, but where solvent must be kept at a minimum, an exhaust rate of GO cfm per sq ft of uea is commonly employed. Where this rate is used, oontrol will be adsquate only if the tank b located in an area free of drafts and if the degreasing operations are carried out in accordance with a rigid schedule.* and workmanlike manner. Hie interior of all ducts shall be smooth and free from obstructions; with joints either welded, flanged, or soldered airtight. Materials 1. Ducts shall be constructed of block iron welded or of galvanized sheet steel riveted and soldered unless the presence of corrosive gases, vapors, and mists or other conditions make use of such material impracticable. Galvanized construction is not recommended for temperatures exceeding 400 F. Welding of black iron of 18 gage and lighter is not recommended for field fabrication. 2. For average exhaust systems on non-corrosive applications the following metal thickness shall be supplied: Diameter of Straight Ducts (inches) 11. S. Standard Gage for Steel Duct Oass 1 assn - Oass ill Dp to 8............ ................ 24 22 20 ' Over 8 to 18...................... 22 20 18 Over 18 to 30................... 20 18 16 Over 30......... 18 16 14 Class I. Includes non-abrasive applications such as paint spray, woodworking, pharmaceutical and food product, and dis charge ducts from dust collectors. Class II. Includes applications for non-abrasive material in high concentration (low-pressure pneumatic conveying); mod erately abrasive material; and highly abrasive materials in light concentrations. Typical applications are conveying of chomiraila and wood dust; exhaust of foundry shakeouts and unnrf handling systems, gram dusts; coal crushing and screening; exhaust of grit blast cabinets; arid grinding, buffing, and polish ing. Class III. Includes applications for all highly abrasive ma terials in moderate to heavy concentrations and moderately abrasive materials in heavy concentrations such as low-pressure conveying of tobacco; exhaust systems from sand and gnt blast ing nd abrasive cleaning operations, from rock and ore screen ing nnd crushing, from dryers and kilna, and fly ash removal from boiler stacks. Where aluminum, duct is indicated, the following equivalent BAS gage thip.knwm of sheets should be used: Steel--U. S. Standard Gage 26 24 22 20 18 16 14 Aluminum--B 4 S Gage 24 22 20 18 16 14 12 3. For exhaust systems on corrosive applications, considera tion should be given to non-corrosive materials or coatings. (Continued on p. 711)