Document 8ReK9YR0Oj0OaRv222drRQb95
December 27, 19b0
Mr. Paul D. Halley Director of Industrial Hygiene Standard Oil Company of Indiana 910 South Michigan Avenue Chicago 00, Illinois Dear Paul: Thank you for your letter of December 21 requesting toxicity and safe handling information on Pydraul AC. Enclosed are the followingj 1. A technical bulletin (promotional) describing this fluid; 2. A oopy of the acute toxioity screening studies; (in this
report the fluid is identified as OS-67, whioh was the designation for the produot during its developmental stages prior to its becoming a sales item.) 3. Our brief interpretation of the toxioity data. We have had a number of inquiries about the use of this fluid in compressors where the air is subsequently used for supplied air respirators or masks. Due to the low volatility of the components of Pydraul AC, one would expect that no significant quantity of vapors would carry over from the compressor into the compressed air line. We recognize, however, that in com pressor lubrlostion, temperatures may be elevated above the ambient levels depending on the type of compressor, size, state of maintenance, operating temperatures, eto. For this reason, we have always recommended that where the air is to be used for human consumption, a commercial filter cartridge for air supplied masks be incorporated in the supply line. I don't believe this is oritical, but I think good Industrial practice dictates that such a filter should be used regardless of the type of compressor fluid or lubricant. I am, of oourse, referring to a filter cartridge such as is available from MSA.
DSW 018713
STLCOPCB4005257
Mr. Paul D. Halley - Page 2 - December 27, i960
A few months ago. Liberty Mutual industrial hygienists took bomo air samples from a compressor line in one of our plants, at our request. The equipment in question was a Joy Manu facturing Company compressor which had been operating on Pydraul AC for three years. During that time, the Pydraul had not been changed, but had been replenished as needed. It was assumed that the compressor was well cleaned at the time of the change-over and that three years of operation should be adequate to flush any petroleum oil from the line.
Filter paper and silica gel samples were collected and analyzed using a Beckman spectrophotometer after isoootane or isopropanol extraction. No concentrations of the major components of the fluid could be deteoted when the samples were compared with standards developed previously with lmown amounts of the compo nents.
I do not consider this data as oonolusive because of the limited number of samples and recognizing the differences in compressor operating conditions mentioned above. It does, however, sub stantiate our opinion somewhat. Further, in the three or more yearB that Pydraul AC has been used by a number of companies, we have never heard of any difficulties with it other than the unexpected amount of pain or smarting which results from acci dental splashing or wiping of the fluid into the eyes. As enclosure number 3 indicates, the use of suitable eye drops or ointments helps alleviate this condition.
In regard to composition of Pydraul AC, I can only tell you that this is a phosphate ester base fluid containing chlorinated hydrocarbons.
Thank you for your Christmas greetings. I certainly hope that you had a pleasant Christmas and that the new year will be a very happy one,
Sinoerely,
EPWtdh Enclosures 3
Elmer P. Wheeler Assistant Director Medloal Department
OSW 018714
STLCOPCB4005258
TOXICITY OF PYPRAUL AC
In animal tcxloity studies with Pydrsul AC# the oral lethal dose in rats is approximately 40 grams per kilogram and for rabbits, 3*5 to 4,3 grams per kilogram. The greater sensi tivity of rabbits is typical of this type of fluid. This lethal dose is of such an order, however, that the fluid may be considered only "slightly toxio" to man from the stand point of aooldental Ingestion of single oral doses. The fluid may be absorbed through the unbroken skin of rabbits in doses resulting in death, but again the minimum lethal dose Is such that aooldental massive skin exposures to man do not present a hazard. Skin and eye irritation studies with rabbits would classify the fluid as a mild irritant. Laboratory animals survived six-hour exposures to an atmos phere saturated with the vapors of the fluid. On the basis of this data, it is concluded that pydrsul AC requires no speoial handling precautions other than avoiding prolonged or repeated skin contact. Aooldental splashing in the eyes will result in moderately severe pain and irritation but no permanent damage should result. To relieve the irritation, physicians have used l pontocaine solution as well as ophthal mic oortlsone acetate solution.
The material in this report is to be used in development of the product and may be given to responsible sales contact** but it is not to be used by them in advertising copy. The source of this material is not to he divulged until it epponre in formal publications. No c>x< e;. ions to iho ectnb". h. d rule may be made without the nppiov.d r t tne Med.-id l.'epartment in St. Louis.Customers' inqui: i -. veg.-.rding nmi era of toxicity are to be referr 'd us before to tne Medical Depart ment in St. Louis for reply.
-- Monsanto Chemical Company
SW 018715
STLCOPCB4005259