Document 8ReJdYpG7mZGzLMN0xVprRgxy

S-174 131:2695 ENVIRONMENTAL PROTECTION AGENCY REGULATIONS ON TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS (40 CFR 136; 38 FR 28758, October 16, 1973) PART 136--TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS ' Sec. 136.1 136.2 136.3 136.4 . Applicability. Definitions. ' Identification of test procedures. Application for alternate test proce- dures. 136:5 Approval of alternate test procedures. Authority: Sec. 304(g) of Federal Water Pollution Control Act Amendments of 1072 86 Stat. 816, etseq.. Pub. L. 92-500). 136.1 Applicability. The procedures prescribed herein shah, except as noted in $ 136.5, be used to perform the measurements Indicated whenever the waste constituent specified is required to be measured for: (a) An application submitted to the Administrator, or to a State having an approved NPDES program, for a permit under section 402 of the Federal Water Pollution Control Act as amended (FWPCA), and, (b) Reports required to be submitted by dischargers under the NPDES established by Parts 124 and 125 of this chapter; and, (c) Certifications issued by States pur suant to section 401 of the FWPCA, as amended. . 136.2 Definitions. . As used in this part, the term: (a) "Act" means the Federal Water Pollution Control Act, as amended, 33 U.S.C. 1314, et seq. (b) "Administrator" means the Ad ministrator of the U.S. Environmental Protection Agency. (c) "Regional Administrator'' means one of the EPA Regional Administrators. (d) "Director" means the Director of the State Agency authorized to carry out an approved National Pollutant Dis charge Elimination System Program under section 402 of the Act. (e) "National Pollutant Discharge Elimination System (NPDES)" means the national system for the issuance of permits under section 402 of the Act and includes any State or interstate program which has been approved by the Admin istrator, in whole or in part, pursuant to section 402 of-the Act. (f) "Standard Methods" means Stand ard Methods for the Examination of Water and WaSte Water, 13th Edition, 1971. This publication is available from the American Public Health Association, 1015 18th St. NW.. Washington, D.C. 20036. . (g) "A8TM" means Annual Book of Standards, Part 23, Water, Atmospheric Analysis, 1972. This publication is avail able from the American Society for Testing and Materials, 1916 Race St., Philadelphia, Pennsylvania 19103. (h) "jEPA Methods" means Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency. Analytical Quality Control Lab oratory, Cincinnati, Ohio. This publica tion Is available from the Super intendent of Documents, UJ3. Govern ment Printing Office, Washington, .D.C. 20402 (Stock Number 5501-0067). 136.3 Identification of test proce dures. Every parameter or pollutant for which an effluent limitation is now spec ified pursuant to sections 401 and 402 of the Act is named together with test descriptions 'and references in Table I. The discharge parameter values for which reports are required must be de termined by one of the standard ana lytical methods cited and described In Table I, or under certain circum stances by other methods that may be more advantageous to use when such other methods have been previously ap proved by the Regional Administrator of the Region in which the discharge will occur, and providing that the Director of the State in which such discharge will occur does not object to the use of such alternate test procedures. Under certain circumstances the Re gional Administrator or the Director in the Region or State where the discharge will occur may determine for a par ticular discharge that additional param eters or pollutants must be reported. Under such circumstances, additional test procedures for analysis of pollutants may be specified by the Regional Ad ministrator or Director upon the recom mendation of the Director of the Methods Development and Quality As surance Research Laboratory. 136.4 Application for alternate teat procedures. (a) Any person may apply , to the Re gional Administrator in the Region where the discharge occurs for approval of an alternative test procedure. (b) When the discharge for which an alternative test procedure is proposed occurs within a State having a permit program approved pursuant to section 402 of the Act, the applicant shall sub mit his application to the Regional Ad ministrator through the Director of the State agency having responsibility for issuance of NPDES permits within such State. (c) Unless and until printed appllca tlon forms are made available, an appli cation for an alternate test procedure may be made by letter in triplicate. An) application for an alternate test proce dure under this subchapter shall: (1) Provide the name and address o. the responsible person or firm makini the discharge (if not the applicant) ant the applicable ID number of the exlstinj or pending permit, issuing agency, ant type of permit for which the alternate test procedure is requested, and the dis charge serial number. (2) Identify the pollutant or parame ter for which approval of an alternate testing procedure is being requested. (3) Provide justification for usini testing procedures other than those specified in Table I. (4) Provide a detailed description o the proposed alternate test procedure together with references to publishec studies of the applicability of the alter nate test procedure to the effluents it question. 136.5 Approval of alternate test pro cedure*. (a) The Regional Administrator o the region in which the discharge wil occur has final responsibility for ap proval of any alternate test procedure (b) Within thirty days of receipt o an application, the Director will forwan such application, together with his rec ommendations, to the Regional Admin lstrator. Where the Director recommend rejection of the application for sclen tific and technical reasons which he pro vides, the Regional Administrator shal deny the application, and shall forwari a copy of the rejected application ant his decision to the Director of the Stab Permit Program and to the Director o the Methods Development and Qualit; Assurance Research Laboratory. (c) Before approving any applicatioi for an alternate test procedure, the Re gional Administrator shall forward i copy of the application to the Directo; of the Methods Development and Qual ity Assurance Laboratory for review ant recommendation. (d) Within ninety days of receipt bj the Regional Administrator of an appli cation for an alternate test procedure the Regional Administrator shall notifj the applicant and the appropriate State agency of approval or rejection, or shal: specify the additional information which is required to determine whether to ap prove the proposed test procedure. Prloi Copyright < 1973 by The Bureou of National Affair I [Sec. 136.5(d)] DSW 296106 55 STLCOPCB4066050 131:2696 FEDERAL REGULATIONS Table I--List or Approved Test Procedures Parameter and units Method Standard methods References ASTM EPA methods General Analytical methods: 1. Alkalinity as CaCO ling Titration: electrometric, manual or auto- p.870............ p. 143. ... p. 6. CAOOtyliter. mated method--methyl orange. . p. 8. 2. ft.O.D.five-day mg/liter. Modified wiukler or probe method............ p.489............... 3. Chemical oxygen do- Dichromate reflux_ _ ......... -.......... ........... p. 406............ p. 219. inand (C.O>D.) mg/ ' liter. .. 4. Tola! solids mg/liter....... Gravimetric 103-105 C..... ......................... p.536 ... p. 280. 6. Total dissolved (filter- Glass fiber nitration 180 C___-............................... ............. __ p. 276. able) solids mg/llter. > 6. Totfd suspended (non- Glass fiber filtration 103-105 C_.......... p. 637.. __ p. 278. filterable) solids ing/ . liter. ' . 7. Total volatile solidseng/ Gravimetric 650 C____________ ... p. 636....__________ ... p. 282. liter. & Ammonia (as N) mg/ Distillation--nesslcrizationortltnitlonau-........... ......... . . p. 134. liter. . lohtated phenolate. . : p. 141. 9. Sjeldahl nitrogen (os N) Digestion + distillation--nesslcrizatlon or p. 469_______ p. 149. mg/liter, ' titration ulomatcd digestion phenolate. p. 167. 10. Nitrate (as N) mp/lller. Cadmium reduction; brucine sulfate; au- p. 468___ ... p.124. . p. 170. .: tomatcd cadmium or hydrazine rcduc- p. 461,........... . . p. 176. tion. .. p. 185. 11. Total phosphorus (as P) Persulfate digestion and single reagent P.626........ . p. 42.... __ p. 235. xng/uter. (ascorbic acid), or manual digestion, p. 632........... ... p. 246. and automated singlo reagent or stan D. 259, nous chloride. . 12. Acidity mgCaCOj/liter Electrometric end point or plienolphthal- ... p. 148... . eln end point. 18. Total organic carbon Combustion--infrared method1____ ____ p. 267............ . p. 702... ... p. 221. (TOC) mp/liter. 14. Hardness--total tog.. EDTA titration; automated colorimetric p. 179........ . p. 170... .... p. 76. CaCOj/liter. . atomic absorption. .. p. 78. 16. Nitrite (as N) mg/liter. Manual or automated colorimetric dlazotl-_____________ .... p. 185. . ration. p. 195. Analytical metliods for trace metals: 16. Aluminum--total3 mg/ Atomic absorption...................... .................. p. 210 p- 98. liter. .. 17. Antimony--total3 mg/ Atomic absorption ................................. liter. 18. Arsenic--total mg/liter. Digestion plus silver diothylditldocarba- ___p. 13. mate; atomic absorption.3 p. 62.. 10. Barium--total3 mg/llter. Atomic absorption 4................ ......... ........... p. 210. 20. Beryllium--total3 mg/ Aluminon; atomic absorption................. . p. 67. liter. p. 210. 21. Boron--total mp/liter... Curcumln...................................................... p. 69. 22. Cadmium--total3 mg/ Atomic absorption; colorimetric................ p. 210. liter. . u, p. 692... p. 101. 23. Calcium--total3 mg/llter. EDTA titration; Atomic absorption....... p. 84............. .... p. 102. 24. Chromium VI rog/liter. Extraction and atomic absorption; colori p. 429............. .... p. 94. metric. 25. Chromliun--total3 mg/ Atomic absorption; colorimetric........... p. 210.. . p. 692'.. .... p. 104. liter. ' . p. 426... . p. 403.. 26. Cobalt--total3 mgAlter. Atomic absorption *............... ..................... . . p. 692__ 27. Copper--total-mg/liter. Atomic absorption; oolorimetric.............. p. 210.- . p. 692.. ___ p. 106. p. 430... . p.UO.. 28. Iron--total3 mg/liter............. do.................................................... ......... p. 210.. . p. 692_. `.V.Vp.'ios!" p. 433.. . p. 152 29. Lead--total3 mg/liter.___ .^do............ ................................... p. 210-- . p. 692.. _._/p"iib7 p. 436.. 30. Magnesium--total * mg/ Atomic absorption; Gravimetric, p. 210 p. 692.. ;::;-p.Ti2.- liter. '- . p. 416 p. 201 31. Manganese--total1 mg/ Atomic absorption................. p. 210.. p. 692. p. 114. liter. 32. Mercury--total mg/liter. Flameless atomic absorption 1 33. Molybdenum--total * Atomic absorption 1________ _ mg/liter. 34. Nickel--total3 mg/Uter. Atomic absorption; colorimetric *.......... . p. 443. p. 692. 85. Potassium--total3 mg/ Atomic absorption; colorimetric; flame p. 283. p. 326. ____p. 115. . liter, . pholonielric. p. 285 36. Selenium--total rog/Utcr. Atomio absorption3.............................. 37. Silver--tola! *____ _____ Atomic absorption *.................. .................... p. 210........................ 38. Sodium--total* mg/liter. Flame photometric; Atomic absorption____ p. 317............p. 328. ____p. 118. 39. Thalliiun--total3 mg/lltor.. Atomic absorption *______ ______ ___ ..... 40. Tin--total*mg/liler___ ------ do------- .'.____ _______________________ 41. Titanium--total mg/ ........do.............. ................................................. . - liter. 42. Vanadium--total3 mg/ Atomic Absorption; < Colorimetric^... . p. 157.......................... liter. 43. Zinc--total1 mg/liter... Atomic Absorption; Colorimetric_____ p. 210........ p. 602. __ _ p. 120. p. 444 Analytical methods for nu- Irients, anions, and organics: . 44. Organic, nitrogen (as N) Kjeldohl nitrogen minus ammonia p. 468. ____p. 149. mg/litor. nitrogen. 45. Ortho-phosphate (as P) Direct "single reagent; automated single p. 532. ..........P. 42. .. p. 235. mg/llter. reagent or stannous chloride. p. 246. p. 259. 40s Bulfate (as Sf>4) mg/ Graviinelric; turbidimetric; automated p. 331............p. 61.. ____ p. 286. liter. colorimetric--barium chloranilate. p.334..........p. 62_. ____ p. 288. 47. Bulfldc (as S) mg/llLer.. Titriinetrfc--iodine.......... ......... __________ p. 661 ____p. 294, 48. flulflle (as SOj) mg/ Titrlmetric; iodldc-todate............................. p. 337p. 261. 11 tor. 49. Bromide mg/llter.................... do................................................................................ .........p. 216.. 50. Chloride mg/llter........... Silver nitrate; mercuric nitrate; automated p.06._...........p. 23.. ..... p. 29. colorimutrlc-ferrlcyanlde. p. 97.......... . p.-2l_. ..... p. 31. 51. Cyanide--total mg/liter. Distillation--silver nitrate titration or p. 3'J7........... p. 556. ------P- 41. . pyridine pyrazolone colorimetric. . . 52. Fluoride mg/litcr........... Distillation--SPA DNS...................................p. 171p. 191.. p. 64. p. 174 53. Chlorine--total residual Colorimetric; amperometric titration.........p. 382........... p. 223. mg/Uter. 64. Oil And grease mg/llter.. Liquid-Liquid extraction with trichlom- -p. 254.............. ....... : . Irlfluoroethane. .. X Environment Reporter [Sec. 136.5 (Table l>] 56 STLCOPCB4066051 POLLUTANTS ANALYSIS S-174 131:2697 Taiuk T--List or Approved Test Pnofenrucs r&ramclor and units Method Standard methods References ASTM EPA methods 65. Phenols mp/liler............ Colorimetric,`4 AAP............. *........................p. 602............. p.446..............p.232. 66. Surfactants mp/1itor___ Mcthylono blue colorimetric......................... p. 330..............p. 619............. p. 181. 67. Alglddes mg/lihir_____ <as chromatography 1_*_3__*_*_6_________ *..._____ _____ ____ ______ _____ 68. Benaidinp mp/liter........ Dleiotizfttion--colorimetric *........... ............ ............................ ......... . 69. Chlorinated organic Gas chromatography .___ _______ _________ ................___ .............. comtxmuds (except posticldwi) mg/liter. 60. Pesticides mc/Utor........ Gas chromatogtaphy Analytical methods for physical and biological parameters: 61. Color platinum-cobalt Colorimetric; spectrophotometric.......... p. 160 .. p. 38. units or dominant p. 392 wave-length, hue, luminance, purity. 62. Specific conductance 1........... p. 168- p. 284. mho/cm at 26 C. 63. Turbidity Jackson ___ ... p. 467............ p. 808. units. See Note at end of Table I W. Focal streptococci MPN; membrane fdtor; plate count.p. ( bacteria mimbor/100 p.< ml. p. 691L - * ......................, .. . 05. Collform bacteria MPN: Mombrane Altor___ .......................... ^ p. 6691.::==:::r_- - - _ - (focal) uutnbor/100 p. 084l . ......... - -i ml. . 66. Colifonn bacteria \ ,.do.. ____ ....................................... . p. 664l . (total) numbor/iOO p. 679 .................... _ _ ______ ml. Radiological parameters: . 67. Alpha--total p('t/litor.. *____ p. 609................. 08. Ali)ba--counting error .do.. 5............p. 612............. pCl/litor. 69. Beta--total pCl/lilor... Proportional counterf..:.___ ___ _____ p. I 3........ -i p.478.___... 70. Bela--counting error__ ___ do........ p. I 3............p. 478............. pCI/liter. 71. Rndium--total pCi/ liter. 1............p. 674.......... . .................. : p. 617 A number of such systems manufactured by various companies nro considered to be comparablo In tholr per formance. In addition, another technique, based on Combustion-Methane Doleclion, is also'acccptablo. > For (tic determination of total metuls lho sample Is not Altered before processing. Choose a volume of sample appropriate for (lie expected level of metals. If much suspended material is present, as little as 60-100 ml of well-mixed sample will most probably lx* sufficient. (The sample volume required may also vary proportionally with the number of metals to bo determined.) . Transfer a representative aliquot, of the well-mixed sample to a Griffin beaker and add 3 ml of concentrated distilled HNOj. Flare t he beaker on a hotplate and evaporate to dryness making certain that the sample docs not boil. Cool the beaker and add another 3 ml portion of distilled concentrated UNOj. Cover the- beaker with a watch gloss and return to the hotplate. Increase the temperature of the. hotplate so that a gentle reflux action occurs. Continue heating, adding additional acid us necessary until flic digestion is completo, generally indicated by a light colored residue. Add (1:1 with distilled water) distilled concentrated IIC1 in an amount sufficient to dissolve tlio rcsiduo upon warm ing. Wash down the beaker walls and the watch glass with distilled water and filter the sample to remove silicates and other insoluble material Hint could clog the atomizer. Adjust Lho volume to somo predetermined valuo based on the ex|>eded metal concentrations. The sample is now ready for analysis. Concentrations so doterminod shall be reported ns "total". . 3 See I). C. Manning. "Technical Notes", Atomic Absorption Newsletter, Vol. 10, No. 0 p. 123, 1971. Available from IVrkiu-Rlmer Corporation, Main Avenue, Norwalk, Connectieul06852. < Atomic absorption method available from Methods Development and Quality Assurance Roscarch Laboratory, Nnlional Environmental Research ('enter, USKL'A, Cincinnati, Ohio 46268. a For updated method, see: Journal of lho American Water Works Association 64, No. 1, pp. 20-26 (Jan, 1972) or ASTM Method )> 3223-73, American Society for Testing and Materials Headquarters, 1916 Race St., PhUadclplua, Fa. I`il03. . 6 Interim procedures for nlgieldes, chlorinated organic compounds, and pesticides can lie obtained from the Methods Development.and Quality Assuraue-o Research Lulioralory, National Environmental Research Center, USEPA, Citicinnnli, Ohio 46268. 1 Benzidine may be estimated l>y the method of M.A. El-Dib, "Colorimetric Determination of Aniline Derivatives in Natural Waters", El-Dib, M.A., Journal of the Association of Odieiul Anulylicul Chemists, Vol. 64, No. 6, Nov., 1971, pp. I3H3-1387. (As n prescreening measurement. . to the expiration of such ninety day pe riod, a recommendation providing the scientific and other technical basis for acceptance or rejection will be forwarded to the Regional Administrator by the Di rector of the Methods Development and Quality Assurance Research Laboratory. A copy of all approval and rejection notifications will be forwarded to th< Director, Methods Development anc Quality Assurance Research Laboratory for the purposes of national coordination x Copyright <S 1973 by The Bureau of National Affairs, Inc. DSW 296108 [Sec. 136.5(d)] 57 STLCOPCB4066052