Document 8ReJdYpG7mZGzLMN0xVprRgxy
S-174
131:2695
ENVIRONMENTAL PROTECTION AGENCY REGULATIONS ON TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS
(40 CFR 136; 38 FR 28758, October 16, 1973)
PART 136--TEST PROCEDURES FOR THE
ANALYSIS OF POLLUTANTS
'
Sec. 136.1 136.2 136.3 136.4 .
Applicability.
Definitions.
'
Identification of test procedures.
Application for alternate test proce-
dures.
136:5 Approval of alternate test procedures.
Authority: Sec. 304(g) of Federal Water Pollution Control Act Amendments of 1072 86 Stat. 816, etseq.. Pub. L. 92-500).
136.1 Applicability.
The procedures prescribed herein
shah, except as noted in $ 136.5, be used
to perform the measurements Indicated
whenever the waste constituent specified
is required to be measured for:
(a) An application submitted to the
Administrator, or to a State having an
approved NPDES program, for a permit
under section 402 of the Federal Water
Pollution Control Act as amended
(FWPCA), and,
(b) Reports required to be submitted
by dischargers under the NPDES
established by Parts 124 and 125 of this
chapter; and,
(c) Certifications issued by States pur
suant to section 401 of the FWPCA, as
amended.
.
136.2 Definitions.
.
As used in this part, the term:
(a) "Act" means the Federal Water
Pollution Control Act, as amended, 33
U.S.C. 1314, et seq.
(b) "Administrator" means the Ad
ministrator of the U.S. Environmental
Protection Agency.
(c) "Regional Administrator'' means
one of the EPA Regional Administrators.
(d) "Director" means the Director of
the State Agency authorized to carry
out an approved National Pollutant Dis
charge Elimination System Program
under section 402 of the Act.
(e) "National Pollutant Discharge
Elimination System (NPDES)" means
the national system for the issuance of
permits under section 402 of the Act and
includes any State or interstate program
which has been approved by the Admin
istrator, in whole or in part, pursuant to
section 402 of-the Act.
(f) "Standard Methods" means Stand
ard Methods for the Examination of
Water and WaSte Water, 13th Edition,
1971. This publication is available from
the American Public Health Association,
1015 18th St. NW.. Washington, D.C.
20036.
.
(g) "A8TM" means Annual Book of
Standards, Part 23, Water, Atmospheric
Analysis, 1972. This publication is avail
able from the American Society for Testing and Materials, 1916 Race St., Philadelphia, Pennsylvania 19103.
(h) "jEPA Methods" means Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency. Analytical Quality Control Lab oratory, Cincinnati, Ohio. This publica tion Is available from the Super intendent of Documents, UJ3. Govern ment Printing Office, Washington, .D.C. 20402 (Stock Number 5501-0067).
136.3 Identification of test proce dures.
Every parameter or pollutant for which an effluent limitation is now spec ified pursuant to sections 401 and 402 of the Act is named together with test descriptions 'and references in Table I. The discharge parameter values for which reports are required must be de termined by one of the standard ana lytical methods cited and described In Table I, or under certain circum stances by other methods that may be more advantageous to use when such other methods have been previously ap proved by the Regional Administrator of the Region in which the discharge will occur, and providing that the Director of the State in which such discharge will occur does not object to the use of such alternate test procedures.
Under certain circumstances the Re gional Administrator or the Director in the Region or State where the discharge will occur may determine for a par ticular discharge that additional param eters or pollutants must be reported. Under such circumstances, additional test procedures for analysis of pollutants may be specified by the Regional Ad ministrator or Director upon the recom mendation of the Director of the Methods Development and Quality As surance Research Laboratory.
136.4 Application for alternate teat procedures.
(a) Any person may apply , to the Re gional Administrator in the Region where the discharge occurs for approval of an alternative test procedure.
(b) When the discharge for which an alternative test procedure is proposed occurs within a State having a permit program approved pursuant to section 402 of the Act, the applicant shall sub mit his application to the Regional Ad ministrator through the Director of the State agency having responsibility for issuance of NPDES permits within such State.
(c) Unless and until printed appllca tlon forms are made available, an appli cation for an alternate test procedure may be made by letter in triplicate. An) application for an alternate test proce dure under this subchapter shall:
(1) Provide the name and address o. the responsible person or firm makini the discharge (if not the applicant) ant the applicable ID number of the exlstinj or pending permit, issuing agency, ant type of permit for which the alternate test procedure is requested, and the dis charge serial number.
(2) Identify the pollutant or parame ter for which approval of an alternate testing procedure is being requested.
(3) Provide justification for usini testing procedures other than those specified in Table I.
(4) Provide a detailed description o the proposed alternate test procedure together with references to publishec studies of the applicability of the alter nate test procedure to the effluents it question.
136.5 Approval of alternate test pro cedure*.
(a) The Regional Administrator o the region in which the discharge wil occur has final responsibility for ap proval of any alternate test procedure
(b) Within thirty days of receipt o an application, the Director will forwan such application, together with his rec ommendations, to the Regional Admin lstrator. Where the Director recommend rejection of the application for sclen tific and technical reasons which he pro vides, the Regional Administrator shal deny the application, and shall forwari a copy of the rejected application ant his decision to the Director of the Stab Permit Program and to the Director o the Methods Development and Qualit; Assurance Research Laboratory.
(c) Before approving any applicatioi for an alternate test procedure, the Re gional Administrator shall forward i copy of the application to the Directo; of the Methods Development and Qual ity Assurance Laboratory for review ant recommendation.
(d) Within ninety days of receipt bj the Regional Administrator of an appli cation for an alternate test procedure the Regional Administrator shall notifj the applicant and the appropriate State agency of approval or rejection, or shal: specify the additional information which is required to determine whether to ap prove the proposed test procedure. Prloi
Copyright < 1973 by The Bureou of National Affair I
[Sec. 136.5(d)]
DSW 296106
55
STLCOPCB4066050
131:2696
FEDERAL REGULATIONS
Table I--List or Approved Test Procedures
Parameter and units
Method
Standard methods
References ASTM
EPA methods
General Analytical methods: 1. Alkalinity as CaCO ling Titration: electrometric, manual or auto- p.870............ p. 143. ... p. 6.
CAOOtyliter.
mated method--methyl orange.
.
p. 8.
2. ft.O.D.five-day mg/liter. Modified wiukler or probe method............ p.489...............
3. Chemical oxygen do- Dichromate reflux_ _ ......... -.......... ........... p. 406............ p. 219.
inand (C.O>D.) mg/
' liter.
..
4. Tola! solids mg/liter....... Gravimetric 103-105 C..... ......................... p.536
... p. 280.
6. Total dissolved (filter- Glass fiber nitration 180 C___-............................... .............
__ p. 276.
able) solids mg/llter.
>
6. Totfd suspended (non- Glass fiber filtration 103-105 C_.......... p. 637..
__ p. 278.
filterable) solids ing/
.
liter. ' .
7. Total volatile solidseng/ Gravimetric 650 C____________ ... p. 636....__________
... p. 282.
liter.
& Ammonia (as N) mg/ Distillation--nesslcrizationortltnitlonau-........... ......... .
. p. 134.
liter.
. lohtated phenolate. . :
p. 141.
9. Sjeldahl nitrogen (os N) Digestion + distillation--nesslcrizatlon or p. 469_______
p. 149.
mg/liter,
' titration ulomatcd digestion phenolate.
p. 167.
10. Nitrate (as N) mp/lller. Cadmium reduction; brucine sulfate; au- p. 468___ ... p.124.
. p. 170.
.:
tomatcd cadmium or hydrazine rcduc- p. 461,........... .
. p. 176.
tion.
..
p. 185.
11. Total phosphorus (as P) Persulfate digestion and single reagent P.626........ . p. 42.... __ p. 235.
xng/uter.
(ascorbic acid), or manual digestion, p. 632...........
... p. 246.
and automated singlo reagent or stan
D. 259,
nous chloride.
.
12. Acidity mgCaCOj/liter Electrometric end point or plienolphthal- ...
p. 148...
. eln end point.
18. Total organic carbon Combustion--infrared method1____ ____ p. 267............ . p. 702... ... p. 221.
(TOC) mp/liter.
14. Hardness--total tog.. EDTA titration; automated colorimetric p. 179........ . p. 170... .... p. 76.
CaCOj/liter. .
atomic absorption.
.. p. 78.
16. Nitrite (as N) mg/liter. Manual or automated colorimetric dlazotl-_____________
.... p. 185.
. ration.
p. 195.
Analytical metliods for trace
metals:
16. Aluminum--total3 mg/ Atomic absorption...................... .................. p. 210
p- 98.
liter.
..
17. Antimony--total3 mg/ Atomic absorption .................................
liter.
18. Arsenic--total mg/liter. Digestion plus silver diothylditldocarba-
___p. 13.
mate; atomic absorption.3
p. 62..
10. Barium--total3 mg/llter. Atomic absorption 4................ ......... ........... p. 210.
20. Beryllium--total3 mg/ Aluminon; atomic absorption................. . p. 67.
liter.
p. 210.
21. Boron--total mp/liter... Curcumln...................................................... p. 69.
22. Cadmium--total3 mg/ Atomic absorption; colorimetric................ p. 210.
liter.
.
u,
p. 692...
p. 101.
23. Calcium--total3 mg/llter. EDTA titration; Atomic absorption....... p. 84.............
.... p. 102.
24. Chromium VI rog/liter. Extraction and atomic absorption; colori p. 429.............
.... p. 94.
metric.
25. Chromliun--total3 mg/ Atomic absorption; colorimetric........... p. 210.. . p. 692'.. .... p. 104.
liter.
' . p. 426... . p. 403..
26. Cobalt--total3 mgAlter. Atomic absorption *............... ..................... .
. p. 692__
27. Copper--total-mg/liter. Atomic absorption; oolorimetric.............. p. 210.- . p. 692.. ___ p. 106.
p. 430... . p.UO..
28. Iron--total3 mg/liter............. do.................................................... ......... p. 210.. . p. 692_. `.V.Vp.'ios!"
p. 433.. . p. 152
29. Lead--total3 mg/liter.___ .^do............ ...................................
p. 210-- . p. 692.. _._/p"iib7
p. 436..
30. Magnesium--total * mg/ Atomic absorption; Gravimetric,
p. 210
p. 692.. ;::;-p.Ti2.-
liter.
'-
. p. 416
p. 201
31. Manganese--total1 mg/ Atomic absorption.................
p. 210..
p. 692.
p. 114.
liter.
32. Mercury--total mg/liter. Flameless atomic absorption 1
33. Molybdenum--total * Atomic absorption 1________ _
mg/liter.
34. Nickel--total3 mg/Uter. Atomic absorption; colorimetric *.......... . p. 443.
p. 692.
85. Potassium--total3 mg/ Atomic absorption; colorimetric; flame p. 283.
p. 326. ____p. 115.
. liter,
. pholonielric.
p. 285
36. Selenium--total rog/Utcr. Atomio absorption3..............................
37. Silver--tola! *____ _____ Atomic absorption *.................. .................... p. 210........................
38. Sodium--total* mg/liter. Flame photometric; Atomic absorption____ p. 317............p. 328. ____p. 118.
39. Thalliiun--total3 mg/lltor.. Atomic absorption *______ ______ ___ .....
40. Tin--total*mg/liler___ ------ do------- .'.____ _______________________
41. Titanium--total mg/ ........do.............. .................................................
. - liter.
42. Vanadium--total3 mg/ Atomic Absorption; < Colorimetric^... . p. 157..........................
liter.
43. Zinc--total1 mg/liter... Atomic Absorption; Colorimetric_____
p. 210........ p. 602.
__ _ p. 120.
p. 444
Analytical methods for nu-
Irients, anions, and organics:
. 44. Organic, nitrogen (as N) Kjeldohl nitrogen minus ammonia p. 468.
____p. 149.
mg/litor.
nitrogen.
45. Ortho-phosphate (as P) Direct "single reagent; automated single p. 532. ..........P. 42. ..
p. 235.
mg/llter.
reagent or stannous chloride.
p. 246.
p. 259.
40s Bulfate (as Sf>4) mg/ Graviinelric; turbidimetric; automated p. 331............p. 61.. ____ p. 286.
liter.
colorimetric--barium chloranilate.
p.334..........p. 62_. ____ p. 288.
47. Bulfldc (as S) mg/llLer.. Titriinetrfc--iodine.......... ......... __________ p. 661
____p. 294,
48. flulflle (as SOj) mg/ Titrlmetric; iodldc-todate............................. p. 337p. 261.
11 tor.
49. Bromide mg/llter.................... do................................................................................ .........p. 216..
50. Chloride mg/llter........... Silver nitrate; mercuric nitrate; automated p.06._...........p. 23.. ..... p. 29.
colorimutrlc-ferrlcyanlde.
p. 97.......... . p.-2l_. ..... p. 31.
51. Cyanide--total mg/liter. Distillation--silver nitrate titration or p. 3'J7........... p. 556. ------P- 41.
.
pyridine pyrazolone colorimetric.
.
.
52. Fluoride mg/litcr........... Distillation--SPA DNS...................................p. 171p. 191..
p. 64.
p. 174
53. Chlorine--total residual Colorimetric; amperometric titration.........p. 382........... p. 223.
mg/Uter.
64. Oil And grease mg/llter.. Liquid-Liquid extraction with trichlom- -p. 254.............. ....... :
.
Irlfluoroethane.
..
X
Environment Reporter
[Sec. 136.5 (Table l>]
56
STLCOPCB4066051
POLLUTANTS ANALYSIS
S-174
131:2697
Taiuk T--List or Approved Test Pnofenrucs
r&ramclor and units
Method
Standard methods
References ASTM
EPA methods
65. Phenols mp/liler............ Colorimetric,`4 AAP............. *........................p. 602............. p.446..............p.232.
66. Surfactants mp/1itor___ Mcthylono blue colorimetric......................... p. 330..............p. 619............. p. 181.
67. Alglddes mg/lihir_____ <as chromatography 1_*_3__*_*_6_________ *..._____ _____ ____ ______ _____
68. Benaidinp mp/liter........ Dleiotizfttion--colorimetric *........... ............ ............................ ......... .
69. Chlorinated organic Gas chromatography .___ _______ _________ ................___ ..............
comtxmuds (except
posticldwi) mg/liter.
60. Pesticides mc/Utor........ Gas chromatogtaphy
Analytical methods for
physical and biological
parameters:
61. Color platinum-cobalt Colorimetric; spectrophotometric.......... p. 160
.. p. 38.
units or dominant
p. 392
wave-length, hue,
luminance, purity.
62. Specific conductance
1........... p. 168-
p. 284.
mho/cm at 26 C.
63. Turbidity Jackson
___ ... p. 467............ p. 808.
units.
See Note at end of Table I
W. Focal streptococci
MPN; membrane fdtor; plate count.p. (
bacteria mimbor/100
p.<
ml. p. 691L
- * ......................, ..
.
05. Collform bacteria
MPN: Mombrane Altor___ .......................... ^ p. 6691.::==:::r_- - - _ -
(focal) uutnbor/100
p. 084l . .........
- -i
ml.
. 66. Colifonn bacteria
\ ,.do..
____ ....................................... . p. 664l
.
(total) numbor/iOO
p. 679 .................... _ _ ______
ml.
Radiological parameters: .
67. Alpha--total p('t/litor..
*____ p. 609.................
08. Ali)ba--counting error
.do..
5............p. 612.............
pCl/litor.
69. Beta--total pCl/lilor... Proportional counterf..:.___ ___ _____ p. I
3........ -i p.478.___...
70. Bela--counting error__ ___ do........ p. I
3............p. 478.............
pCI/liter.
71. Rndium--total pCi/ liter.
1............p. 674.......... . .................. : p. 617
A number of such systems manufactured by various companies nro considered to be comparablo In tholr per
formance. In addition, another technique, based on Combustion-Methane Doleclion, is also'acccptablo.
> For (tic determination of total metuls lho sample Is not Altered before processing. Choose a volume of sample
appropriate for (lie expected level of metals. If much suspended material is present, as little as 60-100 ml of well-mixed
sample will most probably lx* sufficient. (The sample volume required may also vary proportionally with the number
of metals to bo determined.)
.
Transfer a representative aliquot, of the well-mixed sample to a Griffin beaker and add 3 ml of concentrated distilled
HNOj. Flare t he beaker on a hotplate and evaporate to dryness making certain that the sample docs not boil. Cool
the beaker and add another 3 ml portion of distilled concentrated UNOj. Cover the- beaker with a watch gloss and
return to the hotplate. Increase the temperature of the. hotplate so that a gentle reflux action occurs. Continue heating,
adding additional acid us necessary until flic digestion is completo, generally indicated by a light colored residue.
Add (1:1 with distilled water) distilled concentrated IIC1 in an amount sufficient to dissolve tlio rcsiduo upon warm
ing. Wash down the beaker walls and the watch glass with distilled water and filter the sample to remove silicates
and other insoluble material Hint could clog the atomizer. Adjust Lho volume to somo predetermined valuo based
on the ex|>eded metal concentrations. The sample is now ready for analysis. Concentrations so doterminod shall be
reported ns "total".
.
3 See I). C. Manning. "Technical Notes", Atomic Absorption Newsletter, Vol. 10, No. 0 p. 123, 1971. Available
from IVrkiu-Rlmer Corporation, Main Avenue, Norwalk, Connectieul06852.
< Atomic absorption method available from Methods Development and Quality Assurance Roscarch Laboratory,
Nnlional Environmental Research ('enter, USKL'A, Cincinnati, Ohio 46268.
a For updated method, see: Journal of lho American Water Works Association 64, No. 1, pp. 20-26 (Jan, 1972) or
ASTM Method )> 3223-73, American Society for Testing and Materials Headquarters, 1916 Race St., PhUadclplua,
Fa. I`il03.
.
6 Interim procedures for nlgieldes, chlorinated organic compounds, and pesticides can lie obtained from the Methods
Development.and Quality Assuraue-o Research Lulioralory, National Environmental Research Center, USEPA,
Citicinnnli, Ohio 46268.
1 Benzidine may be estimated l>y the method of M.A. El-Dib, "Colorimetric Determination of Aniline Derivatives
in Natural Waters", El-Dib, M.A., Journal of the Association of Odieiul Anulylicul Chemists, Vol. 64, No. 6, Nov.,
1971, pp. I3H3-1387.
(As n prescreening measurement.
.
to the expiration of such ninety day pe
riod, a recommendation providing the scientific and other technical basis for acceptance or rejection will be forwarded
to the Regional Administrator by the Di rector of the Methods Development and Quality Assurance Research Laboratory. A copy of all approval and rejection
notifications will be forwarded to th< Director, Methods Development anc Quality Assurance Research Laboratory
for the purposes of national coordination
x
Copyright <S 1973 by The Bureau of National Affairs, Inc.
DSW 296108
[Sec. 136.5(d)]
57
STLCOPCB4066052