Document 8RaRGEgwEQ829wpVmEeQepNjy
|Jun, 1962)
^tl^QUananltailiirrecfitinif-farefficiency, economy; durability
3 Oil heating unit for residential and commercial
installations-The Oakmont oil-fired unit is specially de signed to provide clean, modern hot water or steam heat. Built exclusively for automatic operation with oil, the Oakmont is available in a wide range of sizes for both larger residential and commercial installations.
Outstanding features of the Oakmont are its efficiency, economy and durability. Peak efficiency is the result of skillful design and precision engineering. For example, each major component that comprises the quality proven boiler-burner unit-the rugged boiler sections, Model OH-5 Arcoflame burner, automatic controls, special combustion chamber and built-in water heater-has been completely integrated and tested to produce the finest in dependable, low-cost oil heating comfort.
The long-life, corrosion-resistant castings of the Oakmont are machine ground to assure an airtight, iron-to-iron fit. Each sec tion must undergo rigid inspection and testing at 2Vi times normal operating pressure. This careful attention to quality results in years of dependable, customer-satisfying heating comfort.
Jacket designed for easy assembly and servicing -- One of the principal features of the Oakmont oil unit is its ease of servicing. An attractive jacket completely encloses the boiler. An optional jacket extension encloses burner and controls offering easy access to them.
The Oakmont jacket is fabricated from sturdy steel with slip-joint construction for easy assembly and perfect fit. It is attractively styled with modern, small radius corners and is finished in a harmonizing shade of gray that is highly resistant to heat, chipping, and scratching.
The Model DH-5 Arcoflame oil burner-- is an integral part of the Oakmont boiler-burner unit. Technical skill, fine materials and rigid manufacturing standards make this high pressure burner a superior companion for the Oakmont. It is fully laboratory, field and factory tested to assure compliance with rigid American-Standard requirements. Precision die-cast aluminum housing provides ease in handling. The Model DH-5 Arcoflame burner is sling mounted with a unique hanger ar rangement which assures smooth operation and easy, low-cost installation. It burns No. 1 or No. 2 fuel oil.
^ American-Standard Oakmont oil heating units have ratings approved by the Institute of Boiler and Radiator Manu
facturers and are constructed to the specifications of the American Society of Mechanical Engineers. The Model DH-5 Arcoflame oil burner is listed by Underwriters' Laboratories, Inc. for No. 1 and No. 2 fuel oil, complies with Commercial Standard CS-75 and is approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts and by the Department of Police, State of Connecticut.
I
18103
Oil
heating unit numbers
steam
water
oil boiler
steam water
net 1 = B = R rating*
steam
water
Btu/hr sq ft Btu/hr
gross l=B=R output
Btu/hr
l=B=R
burner capacity
gph
chim 'ey
size height inches feet
built-in water heaters
stock no.
type
capacity-gals. 110* boiler water temp.
*S 84 OB *W 84 OB *S 84 *W84 107,300 447 107,300 143,000 1.40 8x8 20 'S 85 OB *W 85 OB *S 85 *W 85 131,300 547 131.300 175,000 1.75 8x8 25 S 86 OB W 86 OB S 86 W 86 151,500 631 151,500 202,000 2.00 8x8 25 S 87 OB W 87 OB SS7 VV 8/ 172,500 719 172,500 2SV'ViXi 2.30 O A 12 30 S 88 OB W 88 OB S 88 W 88 195,800 816 195,800 261,000 2.55 8 x 12 30 S 89 OB W 89 OB S 89 W 89 216,100 900 216,100 288,000 2.80 8x12 35
583 tankless 585 tankless 597 tankless
598 599 tank
3 per min. 3V2 per rnin. 4% per m;n.
40 100
uiit-in water heaters may be used with any Oakmont boiler.
Oil heating unit numOer includes Model DH-5 Arcoflame oil burner.
Note; Nozzle sizes, gph. 60* S. furnished with Oakmont oil heating
units: No. 84. 1.35; No. 85. 1.65; No. 86, 2.00; No. 87, 2.25; No. 88. 2.50;
No. 89. 2.75.
Equipped with crown sheet baffle.
# Net l = B = R ratings shown include allowances for normal piping loss and pick up load. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements.
dimensions and tappings
extended jacket
flush jacket
boiler number
A
B
c
D
L
S or W 84 14 _ 26% 15
40%
S or W 85 14 -- 30% 18% 44%
extended S or W 86 14
7 26% 22
47%
jacket
S or W 87 14
7 30% 25% 51%
S or W 88 14 14 26% 29
54%
S or W 89 14 14 30% 32% 58%
flush jacket
boiler number
S or W 84 S or W 85 S or W 86 S or W 87 S or W 88 S or W 89
:j:a'A3v inroocc
:e::
AB
14 14 14 7 14 7 14 14 14 14
cD
11 14% 11 u% 11 14%
15 18% 22 25% 29 32%
l
25 28% 32 35% 39 42%
assemblage of sections
boiler number
S or W 84 S or W 85 S or W 86 S or W 87 S or W 88 S or W 89
legend:
arrangement of sections
F-CX-B F-CX-NC-B F-CX-CX-B F-CX-CX-NC-B F-CX-C-CX-B F-CX-C-CX-NC-B
F-7~ front section C-7" center section CX-7" center connecting section NC-3V?" narrow center section S-6V2" back section
control applications
location size on boiler inehes
steam or vapor
A and 8
l
eiternai low water control or feeder
C 2Vi V*
F G H
inserted m smoke pipe
1V2 y%
n'*
-
internal low water cut-off operating temperature control for tankless heaters operating temperature control for tank type heaters blow-off pressure controiT safety valve
Stack control
water
`'A" alternate water limit control "B" reverse acting water temperature control
water limit control
operating temperature control for tankless heaters
operating temperature control for tank type heaters
alternate water limit control
not used
relief valve
stick control
T vapor cor
No JibO t Re*
^ American-Standard Oakmont Oil-fired Heating Units are another development in hydromcs --the science of heating and cooling with water.
American-Standard plumbing and heating division
AMERICAN RADIATOR 4 STANDARD SANITARY CORPORATION AO WEST AOTH STREET NEW YORK 18. NEW YORK
18104