|Jun, 1962) ^tl^QUananltailiirrecfitinif-farefficiency, economy; durability 3 Oil heating unit for residential and commercial installations-The Oakmont oil-fired unit is specially de signed to provide clean, modern hot water or steam heat. Built exclusively for automatic operation with oil, the Oakmont is available in a wide range of sizes for both larger residential and commercial installations. Outstanding features of the Oakmont are its efficiency, economy and durability. Peak efficiency is the result of skillful design and precision engineering. For example, each major component that comprises the quality proven boiler-burner unit-the rugged boiler sections, Model OH-5 Arcoflame burner, automatic controls, special combustion chamber and built-in water heater-has been completely integrated and tested to produce the finest in dependable, low-cost oil heating comfort. The long-life, corrosion-resistant castings of the Oakmont are machine ground to assure an airtight, iron-to-iron fit. Each sec tion must undergo rigid inspection and testing at 2Vi times normal operating pressure. This careful attention to quality results in years of dependable, customer-satisfying heating comfort. Jacket designed for easy assembly and servicing -- One of the principal features of the Oakmont oil unit is its ease of servicing. An attractive jacket completely encloses the boiler. An optional jacket extension encloses burner and controls offering easy access to them. The Oakmont jacket is fabricated from sturdy steel with slip-joint construction for easy assembly and perfect fit. It is attractively styled with modern, small radius corners and is finished in a harmonizing shade of gray that is highly resistant to heat, chipping, and scratching. The Model DH-5 Arcoflame oil burner-- is an integral part of the Oakmont boiler-burner unit. Technical skill, fine materials and rigid manufacturing standards make this high pressure burner a superior companion for the Oakmont. It is fully laboratory, field and factory tested to assure compliance with rigid American-Standard requirements. Precision die-cast aluminum housing provides ease in handling. The Model DH-5 Arcoflame burner is sling mounted with a unique hanger ar rangement which assures smooth operation and easy, low-cost installation. It burns No. 1 or No. 2 fuel oil. ^ American-Standard Oakmont oil heating units have ratings approved by the Institute of Boiler and Radiator Manu facturers and are constructed to the specifications of the American Society of Mechanical Engineers. The Model DH-5 Arcoflame oil burner is listed by Underwriters' Laboratories, Inc. for No. 1 and No. 2 fuel oil, complies with Commercial Standard CS-75 and is approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts and by the Department of Police, State of Connecticut. I 18103 Oil heating unit numbers steam water oil boiler steam water net 1 = B = R rating* steam water Btu/hr sq ft Btu/hr gross l=B=R output Btu/hr l=B=R burner capacity gph chim 'ey size height inches feet built-in water heaters stock no. type capacity-gals. 110* boiler water temp. *S 84 OB *W 84 OB *S 84 *W84 107,300 447 107,300 143,000 1.40 8x8 20 'S 85 OB *W 85 OB *S 85 *W 85 131,300 547 131.300 175,000 1.75 8x8 25 S 86 OB W 86 OB S 86 W 86 151,500 631 151,500 202,000 2.00 8x8 25 S 87 OB W 87 OB SS7 VV 8/ 172,500 719 172,500 2SV'ViXi 2.30 O A 12 30 S 88 OB W 88 OB S 88 W 88 195,800 816 195,800 261,000 2.55 8 x 12 30 S 89 OB W 89 OB S 89 W 89 216,100 900 216,100 288,000 2.80 8x12 35 583 tankless 585 tankless 597 tankless 598 599 tank 3 per min. 3V2 per rnin. 4% per m;n. 40 100 uiit-in water heaters may be used with any Oakmont boiler. Oil heating unit numOer includes Model DH-5 Arcoflame oil burner. Note; Nozzle sizes, gph. 60* S. furnished with Oakmont oil heating units: No. 84. 1.35; No. 85. 1.65; No. 86, 2.00; No. 87, 2.25; No. 88. 2.50; No. 89. 2.75. Equipped with crown sheet baffle. # Net l = B = R ratings shown include allowances for normal piping loss and pick up load. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements. dimensions and tappings extended jacket flush jacket boiler number A B c D L S or W 84 14 _ 26% 15 40% S or W 85 14 -- 30% 18% 44% extended S or W 86 14 7 26% 22 47% jacket S or W 87 14 7 30% 25% 51% S or W 88 14 14 26% 29 54% S or W 89 14 14 30% 32% 58% flush jacket boiler number S or W 84 S or W 85 S or W 86 S or W 87 S or W 88 S or W 89 :j:a'A3v inroocc :e:: AB 14 14 14 7 14 7 14 14 14 14 cD 11 14% 11 u% 11 14% 15 18% 22 25% 29 32% l 25 28% 32 35% 39 42% assemblage of sections boiler number S or W 84 S or W 85 S or W 86 S or W 87 S or W 88 S or W 89 legend: arrangement of sections F-CX-B F-CX-NC-B F-CX-CX-B F-CX-CX-NC-B F-CX-C-CX-B F-CX-C-CX-NC-B F-7~ front section C-7" center section CX-7" center connecting section NC-3V?" narrow center section S-6V2" back section control applications location size on boiler inehes steam or vapor A and 8 l eiternai low water control or feeder C 2Vi V* F G H inserted m smoke pipe 1V2 y% n'* - internal low water cut-off operating temperature control for tankless heaters operating temperature control for tank type heaters blow-off pressure controiT safety valve Stack control water `'A" alternate water limit control "B" reverse acting water temperature control water limit control operating temperature control for tankless heaters operating temperature control for tank type heaters alternate water limit control not used relief valve stick control T vapor cor No JibO t Re* ^ American-Standard Oakmont Oil-fired Heating Units are another development in hydromcs --the science of heating and cooling with water. American-Standard plumbing and heating division AMERICAN RADIATOR 4 STANDARD SANITARY CORPORATION AO WEST AOTH STREET NEW YORK 18. NEW YORK 18104