JOHNS -MAIMVILLE
T TRANSITED gas vent: 9CJC- SI
An asbestos-cement product
3"
FOR VENTING GAS-FIRED APPLIANCES
im
ADVANTAGES
UL Approved --Tough, Durable
Transits* gas vent is fire-proof; has been continuously-listed by UL since 1932. It is watertight and gastight.. Non-metal lie. Corrosion resistant inside, outside--all the way through; Will not dent or deform. A quiet vent--no "Snap," "Crackle" or "Pop."
Easy to Install --No Fabrication Necessary
Transits gas vent is available in a wide variety of lengths from 4" nipples through 13-foot pipe lengths, but may be ordered in whatever length is heeded. May be fieldcut with snap-cutter or saw If necessary. Simple to Install as shown in the drawings at right and below. For designs involving changes of direction or venting of multiple appliances, a full line of Transite fittings and couplings are available to meet every design need. Joints are made quickly.
fHE COPY
SOla to 50!o Savings on Material
Transite gas vent costs less per foot and may be ordered (n the exact length needed.
ACCEPTANCE
Transite gas vent as a Type B gas vent is accepted through provisions In standards,
codes or listing of the following agencies:
''
1. Underwriters' Laboratories, Inc.
2. Standards, National Board of Fire Underwriters--NBFU No. 54 (Part V) (as recommended by National Fire Protection Association),
3. National Building Code (recommended by National Board of Fire Underwriters).
4. American Standard ASA Z21.30-1959 (American Gas Assoc.).
5. Basic Building Code--BOCA (Sections. 1011 and 1012) (Building Officials Conf.
\ of America). 6. Southern Standard Building Code (Gas--Part Two).
7. International Conference of Building Officials'(Report No. 1134.7).
8. Uniform Building Code (Section 1314) (Western Plumbing Officials Assoc,).
9. Federal Housing Administration Minimum Property Standards (FHA 300--Sec
tion 813-3),
.
'TRANSITE is Johns-Manville'a registered trademark for Its brand of asbestos-cement products.
7 /6 /
CRMC-VentPipe-000028 SC-JMM-0650
SIZING A SINGLE APPLIANCE VENT SYSTEM
[Individual, vents provide greater Reliability] '
'
' ",
When connected to a single appliance, the gas vent shall not be less
than the size of the draft hood outlet. (Source: Standard of NBFU
No. 54 for Installation of Gas Appliance and Gas Piping as recom-.
mended by the National Fire Protection Assoc.)
.
.
SIZING A MULTIPLE APPLIANCE VENT SYSTEM
When more than one appliance is connected to a gas vent the area
of the passageway shall be not less than the area of the largest
connector plus 50% of the. areas of additional vent connectors-- .
(NBFU No. 54).
'
.^
'
PIPE AND FITTINGS While Transits gas vent Is available in lengths as shown below, it may be ordered In any length desired- A full line of couplings and fittings are available to meet every design need. The full line and dimensional data are shown in Johns-Manville brochure TR-289A!
PIPE Sizes--3", 4", 5", 6", 7", 8", 10", 12",
.
Sizes up to 8" available in 5 ft. and 10 ft. lengths; sizes 10" and 12"
available In 6Vi and 13 ft. lengths; all lengths machined both ends,
or with one end un-machined when so ordered.
NIPPLE5
Sizes 3", 4", 5", 6" available In 4", 12", 18", 24", 30", 36" lengths. Size 7" available in 12", 18", 24", 30", 36". Machined both ends.
INSTALLATION INSTRUCTIONS
.
Available In J-M folder TR-251A. Obtain from a J-M Distributor or
J-M District Office.
.
SIZING CHART
3 * 5 6 7 8 9 10 II 12 INSIDE DIAMETER OF VENT IN INCHES Capacity In 6TU per hour for Gas Vents serving more than one appliance.
JOHIUS-MANVILLE i
IVIenufaotupar of TBAIUSITE bulli
40 Street, New York 16, N. Y. for plpo and air duet
Atlanta 3, Georgia 101 Marietta Street 525-2021 Area Code 404
Boston 14, Massachusetts 150 Causeway Street 227 0400 Area Code 617
Chicago, Illinois P.Q. Box 46, Waukegan, 111. 623-2900 Area Code 312 From Chic. DE 71144
Cleveland 15, Ohio 3101 Euclid Avenue UTah 1-6700 Area Code 216
Denver 2, Colorado 1755 Glenarm Piece 292-3380 Aree Code 303
Houston 1, Texas c/o Johns-Manville Denison, Texas 465-6390 Area Code 214
Los Angeles, California P.O. Box D, Long Beach 10 SPruce 5-3451 or TErmlnal 4 6471 Area Code 213
New York, N. Y. Manvllle, N. J, 725-5000 Area Code 201 From NY 227-4991
Philadelphia 6, Pennsylvania Chestnut Street at 4th WAInut 2-5000 Ansa Coda 215
St, Louis 5, Missouri . 7912 Bonhomme Ave., Clayton PArkvIew 1-4000 Area Code 314
San Francisco California P.O. Sox 1587, Stockton. Cal. HOward 4-7341 Area Code 209 From SF DOuglas 2-4353 From Oakland Olympic 8-1262
Seattle 3, Washington
-
4304 Stone Way
MEIrose 3-4300 Area Code 206
CANADIAN JOHNS-MANVILLE CO., LTD. Montreal Ottawa Toronto Vancouver Winnipeg
JOHNS-MANVILLE INTERNATIONAL CORP. Beirut Blienos Aires Goteborg Hong Kong Lagos Lima London Madrid Mexico City Milan * New York * Paris San Juan Sao Paulo Wiesbaden
CRMC-VentPipe-000029
AFFIDAVIT
STATE OF COLORADO COUNTY OF ADAMS
) ) ss. )
1, Margaret J. Baumgardner, being of full age and first duly sworn do hereby state:
1. I am not a party to thi s action. I have personal knowledge ofthe facts set forth in this affidavit, and if called as a witness, I could and would competently testify as to the truth of the matters set forth herein,
2. Iam the Research Coordinator for the Claims Resolution Management Corporation ("CRMC"), a wholly owned subsidiary ofthe Manville Personal Injury Settlement Trust ("Trust"). The CRMC was created in December 1998 and is staffed by former Trust employees. On January 1, 1999, CRMC began providing claims resolution facility services to the Trust,
3. In this position, I manage the Asbestos Claims Research Facility ("Facility"), a document and records repository located at 3390 Peoria Street, Suite 304, Aurora, Colorado. The Facility contains the business records including but not limited to correspondence, memoranda, reports, records and data compilations ("record") of Manville Corporation or related entities ("Manville"), generally, as well as Manville records relevant to litigation of asbestos liability. The Trust has managed and operated the Facility from November 28, 1988, the date on which the Manville bankruptcy plan was consummated.
4. My experience and familiarity with the documents at the Facility began in 1983 while working for Manville. In my work as a paralegal for Manville, I assisted in locating, indexing and packing many of the records which became the foundation documents for the Facility. I continued to work for Manville until September 1987. From March 1988 to September 1988,1 was hired to supervise and assist in the indexing ofthe first 20,000 boxes which were turned over to the Trust in November 1988. From September 1988 to January 1989, I assisted in the privilege review of documents to be given to the Trust. From November 1988 to April 1994,1 worked for Freeborn & Peters and was put in charge of the Facility, managing all productions and "new" acquisitions. In September 1995,1 was hired by the Trust to manage the Facility. In December 1998,1 was hired by
the CRMC to manage the Facility for the Trust. Accordingly, I am personally familiar with many of the records stored at the Facility, as well as how the records have been gathered.
5. To the best ofmy knowledge, information and belief, I certify that these records were made at or near the time by, or from information transmitted by, a person with knowledge, were kept in the course ofthe regularly conducted business activity ofManville, and it was the regular practice and the business activity of Manville to make the records.
6. Attached are documents found among the product file collections at the Facility. These documents, bates labeled CRMC-VentPipe-000001 through CRMC-VentPipe-000035, are true and correct copies of documents found at the Facility.
r
Subscribed and sworn to before of September,
NOTARY PUBLIC
STATE OF COLORADO
MYCOMMISSION EXPIRES 05-23-2016