Document 8RKxYvkB2bv0aygnL24VkELga
WGK ANALYTICAL RESEARCH AND DEVELOPMENT REPORT
OTHER LOCATIONS
GENERAL OFFICE
W. G. KRUMMRICH PLANT
P.-B. W. K. R. E. K. B. J. R.
Hodges - E1SF Johnson - R2E Keller - TIB Papageorge - B2NJ Savage - B2SL
E. R. Billen 0. L. Bratsch C. F. Bucklev W. C. Enpman G. A. Hlppe A. E. Lelsy E. B. Maurer
R. M. McCutchan . E. E. Steward *--*'*" File
yitlci
Analyoie of Chlerosulfonic Acid Scrubber for PCB1s - Fate of Aroclors in Chlorosulfonic Acid.
PCRSOMNKU:
H. L. Campbell (H. J. Horner)
C*&A
it
Determine efficiency of chlorosulfonic acid scrubber
removing Aroclors present in Dept. 2*16 off-gas.
\
JUSTIFICATIONt
Prevent contamination of product (C/S Acid) and environment with polychlorinated biphenyls.
(UMIAKVt
Our analytical data indicates that chlorosulfonic acid can be an effective scrubbing media for removing entrained organics from certain type: of depart mental off-gases. The effectiveness of a C/S acid scrubber has been shown to be due to its ability to sulfonylate a variety of aromatic compounds including chlorobenzenes, chlorophenols and chlorinated biphenyl. The reaction gives basically sulfonyl chlorides of such compounds, however, in some cases aromatic sulfones might be formed.
A reaction between Aroclor 12<I2 and chlorosulfonic acid has been demonstrated and the principal products identified as sulfonyl chlorides. The derivatives obtained were solid of limited solubility in water and assumed to have very low volatilities. Their stability and toxicity in the environment, compared >to the parent .polychlorinated biphenyls, is not known at this time but should be considered prior to disposal of large amounts for extended periods.
dy
CONFIDENTIAL
HONS 040732
Thu report ti fh property Montonra Company ond tho rmcipiont < rotpomife/o for ita aotekeapinq
rfnpol.'M'on. It (Onfp)ni cenfi^onfio/ in/ormofion of Menianfo Company which mva* npr ha
'aprajvcod, ro*oofd r vnpwfhantad parwana et tan* outtido the company without proper ovthonietien.
Yfco report ii
re*mmed m iteur* hlo or do arrayed.
"
ARAD Report No. 2lk6
Page 2
May 17, 1972
Details
Background
Calculations based on available analytical data indicates that polychlor inated biphenyls (PCB's) are present In department 2>16 (Aroclor) off-gas at about a 30 ppm level. When not sewered, this HC1 pas is passed to
department 217 for chlorosulfonic (C/S) acid production. The inlet gas Is initially scrubbed with C/S acid to remove entrained PCB's. The
spent scrubber is also discharged to the sewer at intervals.
An analysis of the spent scrubber acid was needed to establish efficiency
and determine the contribution to sewer contamination at the time of
disposal. As a result of the analysis of a sample of "t-hour old" acid
from the No, 300 scrubber, additional analytical work was undertaken
to establish the fate of Aroclor introduced into C/S acid.
This report covers the analytical examination of a C/S' acid scrubber sample, and subsequent work to define the fate of Aroclors added to chlorosulfonic acid.
Experimental
,
A. Analyses of C/S Acid Scrubber
Preparation for Analyses
The organic matter present in the c/S acid sample was isolated as hexane extractables by extracting the aqueous hydrolyzate of the acid with solvent. A 25 gram sample was added, under carefully controlled conditions in a specially prepared hydrolysis apparatus, to about 250 mis of ice-water. The hexane extracts of the hydrolyzate were collected for analysis.
Analytical
A quantitative examination of the hexane solution for PCB's was made following our standard PCB analytical procedure. The analysis was concluded by electron capture gas chromatography (EC/GC).
The oily, viscous residue remaining after evaporation of the
hexane was subjected to both infrared and conventional gas
\ chromatographic -analyses. Specific derivatizatlon techniques
were subsequently employed to verify the presence of prominent
chemical classes indicated by the infrared absorption spectra.
Analyses of the derivatizatlon reactions or products were made
by gas chromatography arid infrared.
'
B. Simulated C/S Acid Scrubber
Preparation and Sampling
A sample of sales-grade C/S acid was prepared containing. 360 ppm PCB's as Aroclor 12M2. This concentration approximates the
MONS 040733
AR&D Report No. 2146
Pace 3
May 17, 1972
level that was assumed to have been Introduced Into the actual scrubber via off-gas scrubbing. The simulated scrubber acid was allowed to stand at room temperature (25C). A
25 gram sample was taken at *1 hours after contamination and again after 48 hours.
Analytical
The "4-hour old" sample was Immediately hydrolyzed and a
quantitative analysis for PCB's carried out as described above.
The hydrolysate of the 48-hour sampling was also examined for PCB's. In addition an Infrared absorption analysis was made on a solid residue obtained following the evaporation of the hexane solvent.
Results and Discussion
A. Analyses of Scrubber Sample
'
No detectable amount of PCB's were found In the No. 300 scrubber sample. Based on the sample size used and the related chromato graphic conditions, the lower detection limit was of the order of 100 ppb. The anticipated leyel was in the parts per million range ^250 ppm). Two separate samplings were made, Including one from an apparent sedimentation layer at the bottom of the sample container.
An oily, viscous residue Isolated after solvent removal represented .5? (vol./wt.) of the spent acid. Infrared and conventional
QC analyses Indicated the oil to be a complex mixture with a wide range In volatility. Interpretation of the strong or significant bands of the Infrared spectrum suggested a mixture
of aromatic, sulfonyl chloride-type compounds of different origins.
The attached table of analytical data reports the presence of some compounds of a phenolic origin. This was substantiated by the altered elution times of several peaks when comparing chromatograms before and following the reaction of a portion of the Isolate with a sllylatlng reagent. The reagent used, reacts readily with most phenollcs to form sllyl ethers having altogether different OC elution characteristics than the parent phenols. In assessing the combined analytical data. It would appear that some volume
of off-gas from dept. 236 - and perhaps 233, - have also been > Introduced Into the scrubber.
To verify that the major Identifying characteristic of the
Isolated organic matter was that of an aryl sulfonyl chloride, Its reaction to gaseous ammonia was evaluated by Infrared absorption analysis. The reaction with NH3 proceeds according to the equation:
ArS02Cl + 2 NH3 ,,---------------->ArS02NH2 + NHl)Cl
yielding an aryl sulfonamide (Ref. 1). The two Infrared absorption bands of the common -SOg- group shifts from approximately 1370
MGNS 040734
AR&D Report No. 21^6
Page *)
Nay 17. 1972
and 1175 cm-1 In Stilfonyl chlorides to about 1320 and 1150 cm-1 In the sulfonamide (Ref. 2).
Addition of NH3 to a benzene solution of the oily mixture resulted In a solid derivative having major absorption bands at the sulfonamide absorption frequencies. The observed shifting of the major band frequencies from 1375 to 1325 cm-1 and 1175 to 1155 cm"l confirmed that the organic matter isolated from the spent scrubber was predominantly a mixture of aryl sulfonyl chlorides.
U. Fate of Aroclor In C/S Acid
The results of the preceeding analytical work on the spent scrubber indicated that most of the aromatics entering the scrubber were reacting to form sulfonyl chloride derivatives. Since the identifying data was somewhat general and not necessarily specific with respect to the fate of Aroclor, a sample of sales-grade acid was "doped" with 1242 and examined at specified intervals.
Four hours after contamination of the acid, no detectable quantity of PCB's were found in the hexane extract of the hydrolysate. The sulfonylation of Aroclor 1242 was essentially proven, when strong bands of the -SO2- group were observed in the infrared spectrum of the solid residue obtained at the <18 hour sampling. The type of structures indicated from the reaction products are:
Cl;
0-3-0 I Cl
Cin
and
Cln ^3
O-S-O I Cl
_Sln C~
0-5-0 I
Cl
where n
It is apparent that steric hinderance would prevent the highly chlorinated isomers from reacting. A separate EC/CC examination was made, but railed to provide any clear-cut information In
this regard. It is assumed that for 1242 all major isomers were > sulfonylated to Some degree.
Conclusions
'
!
Our analytical data indicates that chlorosulfonlc acid can be an effective scrubbing media for removing entrained organics from certain types of departmental off-gases. The effectiveness of a C/S acid scrubber has been shown to be due to its ability to sulfonylate a variety of aromatic compounds including chlorobenzene chlorophenols and chlorinated biphenyl. The reaction gives basically sulfonyl chlorides of such compounds, however, in some cases aromatic sulfones might be formed.
MONS 040735
AR4D Report No. 2146
Page 5
Hay 17, 1972
A reaction between Aroclor 1242 and chlorosulfonic acid has been
demonstrated and the principal products Identified as sulfonyl chlorides. The derivatives obtained were solid of limited solubility In water and assumed'to have very low volatilities. Their stability and toxicity In the environment, compared to the parent poly chlorinated biphenyls, is not known at this time but should be
considered prior to disposal of large amounts for extended periods.
References
1. R. L. Shrlner, R. C. Fuson, "Identification of Organic Compounds", 3rd Vol. VIIley, Hew York, N. Y. 1948.
2. N. B. Colthup, et al, "Introduction to Infrared and Raman Spectroscopy", Academic, Hew York, N. Y. 1964.
3. Laboratory Notebook, 16101-16200. 16140.
'
H. L. Campbell dy
HONS 040736
J
Sample______________________
Dept. 217 - Mo. 300 C/S Acid Scrubber
Sunnarv - Analytical Data
_______Description_______________ Analytical_________________________
4-hour old Brown-Black color
EC-gas chromatography: *
No detectable amount of PCB (2)
Conventional - (1C:
Series or groups of peaks eluting up to 3 hrs.
Infrared:
Strong bands at 1375 and 1175 cm ^ found in isolate. Indicative of
-S-Cl group J (sulfonyl chloride
Aromatic ring(s) absorption '*'3065 cm-1
Minor absorption band at 3**75 cm"^ indicates
possible presence of small amounts of phenollcs
Lab Prepared- sales grade C/S with 360 pDm
1242 added
4-hour old (1)
EC/GC: Ho detectable amount of PCB (2)
48-hour old(l)
EC/CC:
x ozV) No detectable amount of PCB (2)
Infrared o
c Isolated solid matter gave strong bands
wu
i 1370 and 1174 cm"-*- Indicative of sulfonyl chloride group
(1) - Sample showed slight but definite discoloration (2) - EC/GC lower detection limit * 100 ppb